Thank you for purchasing a Panamax M4000-PRO Power Management with control system interactive functionality, and congratulations on your choice.

The M4000-PRO features Panamax’s revolutionary AVM (Automatic Voltage Monitoring) circuit, and our exclusive Linear Filtering Technology (LiFT). To- gether, these technologies comprise precisely what our customers have come to expect from Panamax: uncompromised AC protection and purification. Outlet: Rear panel outlets are controlled in three power filtered banks. They are grouped into three (3) switched banks. BlueBOLT™ is included, providing se ...

All messages are encapsulated in standard XML format. As per XML standard, It

is required that the XML version declaration be included at the start of each mes- sage. Messages that do not conform to the standard will be ignored. In addition to the XML version declaration, every message must also specify the type of de- vice (model) and its unique MAC ID (mac) in its root element using the tag. For M4000-PRO, device class is “m4000” and the MAC is expressed with no formatting. An example message would thus look like:

IN LAN OUT

CATV / SAT 1 MAIN POWER 120 VAC/15A IN OUT 15A GND BANK 1 BANK 2 BANK 3 12V BlueBOLT IN PHONE OUT BANK 1 BANK 3 1. AC Inlet: 120 VAC, 15A, IEC 320-C13 do not remove steel retention clip. 2. Circuit Breaker: 120 Vac, 15A 3. Ground lug: Connect to Panamax MOD-series signal protection module grounding busses with 14AWG (<12” length) wire to expand the signal protec- tion capabilities: 4. Outlets: the seven rear panel outlets are grouped into three switched outlet banks. All outlets within an outlet bank are controlled together. Bank 1 has two back panel outlets and incl ...

POWER CYCLE AND OUTLET SEQUENCING

The outlet banks of the M4000-PRO are configured to turn on and off in a programmed sequence where each outlet bank has a set of programmed delay times. Outlet Bank Power Cycle Delay Turn On Delay Turn Off Delay Trigger Enable 1 30 seconds 0 seconds 10 seconds Enabled 2 30 seconds 0 seconds 10 seconds Enabled 3 30 seconds 10 seconds 0 seconds Enabled Power Cycle Delay: When a Power Cycle is initiated, the outlet bank will immediately turn off and then turn back on after the Power Cycle Delay time Turn On Delay: When a Turn On Sequence is initiated, the outl ...

Panamax M4000-PRO user guide recommended for: BMS 16i, ADwin-Pro II, ACPS-6N-120SN, SCHUMACHER VaporGuard Series, MIBOXER FUT043A.

⚠️ Download Safety

The Control Systems Instructions manual (16 pages) is completely safe to download (last scan date: 27/03/2026).

Related PDF Instructions for Panamax M4000-PRO:

Control Systems Equipment: Frequently Requested

Have some Questions about Panamax M4000-PRO Device?

Get valuable and actionable advices from other Panamax M4000-PRO device users. Describe your problem or question, regarding the using of M4000-PRO, in as much detail as possible, and other users will be able to answer you.