Yaesu FTM-3207DE Operating Manual
Read Online
Read the Yaesu FTM-3207DE Operating Manual online using the built-in PDF viewer.
Text of the manual
UHF DIGITAL/ANALOG TRANSCEIVER
FTM-3207DR/DE
Operating Manual
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
FTM-3207DR/DE Operating Manual
Safety Precautions (Be Sure to Read)..................... 3
FTM-3207DR/DE Quick Reference Guide................ 5
Introduction................................................................ 6
Features of this radio................................................ 6
Accessories & Options............................................. 7
Supplied Accessories............................................... 7
Optional Accessories................................................ 7
Installation................................................................. 8
Connecting the Microphone...................................... 8
Connecting the Antenna........................................... 8
Mobile Installation..................................................... 9
Power connection................................................ 10
Base Station Installation..........................................11
AC Power Supplies...............................................11
Front Panel Controls & Switches........................... 12
Front Panel............................................................. 12
Microphone Switches............................................. 14
Microphone (MH-48A6JA)...................................... 14
[P1] button........................................................... 14
[P2] button........................................................... 14
[P3] button (Wires-X)........................................... 14
[P4] button (TX PW/T.CALL)................................ 14
Rear Panel Connectors........................................... 15
Rear Panel.............................................................. 15
Basic Operation....................................................... 16
Turning the Transceiver ON and OFF.................... 16
Inputting the call sign.............................................. 16
Adjusting the Audio Volume Level.......................... 16
Adjusting the Squelch Setting................................. 16
Frequency Navigation............................................. 17
Using the Dial...................................................... 17
Using the MH-48A6JA Microphone..................... 17
Channel Step Selection.......................................... 17
Selecting the communication mode........................ 18
Setting the transmission mode when using the
AMS function....................................................... 19
Transmission.......................................................... 20
Adjusting the transmit power............................... 21
Lock Feature........................................................... 21
Advanced Operation............................................... 22
About the Digital Group ID (DG-ID) feature............ 22
Register the DG-ID number in the
DG-ID memory.................................................... 22
Recall and use the DG-ID number registered
in the DG-ID memory........................................... 23
Restore the DG-ID number to “00” for
both transmit and receive without using the
DG-ID memory.................................................... 24
Use the GM (Group Monitor) with the
DG-ID function..................................................... 24
Digital Personal ID (DP-ID) feature........................ 25
Registering the DP-ID to a DR-2X
digital repeater..................................................... 25
Register the transceivers..................................... 25
Deleting the registered DP-ID.............................. 26
Advanced Operation............................................... 27
Repeater Operation................................................ 27
Checking the Repeater
Uplink (Input) Frequency..................................... 27
Tone Calling (1750 Hz)........................................ 27
CTCSS Operation................................................... 28
Tone Search........................................................ 28
DCS Operation....................................................... 28
DCS Search......................................................... 29
EPCS (Enhanced Paging &
Code Squelch) Operation....................................... 29
Split Tone Operation............................................... 29
DTMF Operation..................................................... 29
Memory Operation................................................... 30
Memory Storage..................................................... 30
Split Memory........................................................ 30
Naming a Memory Channel................................. 30
Memory Recall........................................................ 31
Memory Recall from the Microphone Keypad..... 31
Moving Memory Data to the VFO..................... 31
Memory Only Mode............................................. 31
Masking Memories................................................. 32
Unmasking Memories.......................................... 32
HOME Channel Memory........................................ 32
Changing the frequency of the home channel..... 32
Scanning.................................................................. 33
Basic Scanner Operation........................................ 33
Scan Resume Options......................................... 33
Memory Skip Scanning........................................ 33
Preferential Memory Scan................................... 33
Programmable Memory Scan (PMS)................... 33
Priority Channel Scanning (Dual Watch)............. 33
GM Function............................................................. 34
What is the GM (Group Monitor) Function?............ 34
Displaying all the stations using the GM function.... 34
Reset Procedure/Clone........................................... 35
Reset Procedure..................................................... 35
Microprocessor Resetting.................................... 35
Setup (Menu) Mode Resetting............................. 35
Clone...................................................................... 35
Connecting the WIRES-X feature........................... 36
What is WIRES-X?................................................. 36
Connecting to a WIRES-X digital node
(Recommended)................................................. 36
Connecting to the other node ID or the
other room ID....................................................... 36
Connect and communicate with WIRES-X in
analog mode........................................................... 39
Disconnecting from the node or room................. 39
Miscellaneous Settings........................................... 40
Programming the Key Assignments....................... 40
Keyboard Beeper.................................................... 40
Display Brightness.................................................. 40
Time-Out-Timer (TOT)............................................ 40
Automatic Power Off (APO).................................... 40
Busy Channel Lock-Out (BCLO)............................ 40
TX Deviation Level................................................. 40
MIC Gain Setting.................................................... 40
Displaying the Supply Voltage................................ 41
Displaying the Temperature.................................... 41
Band Edge Beeper................................................. 41
Setup (Menu) Mode................................................. 42
Maintenance............................................................. 45
Care and maintenance........................................... 45
Replacing the fuse.................................................. 45
Replacing the fuse of the
DC power supply cable........................................ 45
Specifications.......................................................... 46
EU Declaration of Conformity.............................. 48
FTM-3207DR/DE Operating Manual
Be sure to read these important precautions, and use this product safely.
Yaesu is not liable for any failures or problems caused by the use or misuse of this product by the
purchaser or any third party. Also, Yaesu is not liable for damages caused through the use of this product
by the purchaser or any third party, except in cases where ordered to pay damages under the laws.
Types and meanings of the marks
DANGER
This mark indicates an imminently hazardous situation, which, if not
avoided, could result in death or serious injury.
WARNING
This mark indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury.
CAUTION
This mark indicates a potentially hazardous situation, which, if not avoided,
may result in minor or moderate injury or only property damage.
Types and meanings of symbols
These symbols signify prohibited actions, which must not be done to use this product safely.
For example:
indicates that the product should not be disassembled.
These symbols signify required actions, which must be done to use this product safely. For
example,:
indicates that the power plug should be disconnected.
DANGER
Safety Precautions (Be Sure to Read)
WARNING
Do not use the device in “regions or aircrafts and
vehicles where its use is prohibited” such as in
hospitals and airplanes.
This may exert an impact on electronic and medical
devices.
Do not use this product while driving or riding a
motorbike. This may result in accidents.
Make sure to stop the car in a safe location first
before use if the device is going to be used by the
driver.
Do not operate the device when flammable gas
is generated.
Doing so may result in fire and explosion.
Never touch the antenna during transmission.
This may result in injury, electric shock and equip-
ment failure.
Do not transmit in crowded places in consider-
ation of people who are fitted with medical devic-
es such as heart pacemakers.
Electromagnetic waves from the device may affect
the medical device, resulting in accidents caused by
malfunctions.
When an alarm goes off with the external anten-
na connected, cut off the power supply to this
radio immediately and disconnect the external
antenna from this radio.
If not, this may result in fire, electric shock and equip-
ment failure.
Do not touch any liquid leaking from the liquid
display with your bare hands.
There is a risk of chemical burns occurring when
the liquid comes into contact with the skin or gets
into the eyes. In this case, seek medical treatment
immediately.
Do not use voltages other than the specified
power supply voltage.
Doing so may result in fire and electric shock.
Do not transmit continuously for long periods of time.
This may cause the temperature of the main body
to rise and result in burns and failures due to over-
heating.
Do not dismantle or modify the device.
This may result in injury, electric shock and equip-
ment failure.
Do not handle the power plug and connector etc.
with wet hands. Also do not plug and unplug the
power plug with wet hands.
This may result in injury, liquid leak, electric shock
and equipment failure.
When smoke or strange odors are emitted from
the radio, turn off the power and disconnect the
power cord from the socket.
This may result in fire, liquid leak, overheating, dam-
age, ignition and equipment failure. Please contact
our company amateur customer support or the retail
store where you purchased the device.
Keep the power plug pins and the surrounding
areas clean at all times.
This may result in fire, liquid leak, overheating,
breakage, ignition etc.
Disconnect the power cord and connection ca-
bles before incorporating items sold separately
and replacing the fuse.
This may result in fire, electric shock and equipment
failure.
FTM-3207DR/DE Operating Manual
CAUTION
Never cut off the fuse holder of the DC power
cord.
This may cause short-circuiting and result in ignition
and fire.
Do not use fuses other than those specified.
Doing so may result in fire and equipment failure.
Do not allow metallic objects such as wires and
water to get inside the product.
This may result in fire, electric shock and equipment
failure.
Do not place the device in areas that may get wet
easily (e.g. near a humidifier).
This may result in fire, electric shock and equipment
failure.
When connecting a DC power cord, pay due care
not to mix up the positive and negative polarities.
This may result in fire, electric shock and equipment
failure.
Do not use DC power cords other than the one
enclosed or specified.
This may result in fire, electric shock and equipment
failure.
Do not bend, twist, pull, heat and modify the pow-
er cord and connection cables in an unreason-
able manner.
This may cut or damage the cables and result in fire,
electric shock and equipment failure.
Do not pull the cable when plugging and unplug-
ging the power cord and connection cables.
Please hold the plug or connector when unplugging.
If not, this may result in fire, electric shock and equip-
ment failure.
Refrain from using headphones and earphones
at a loud volume.
Continuous exposure to loud volumes may result in
hearing impairment.
Do not use the device when the power cord and
connection cables are damaged, and when the
DC power connector cannot be plugged in tight-
ly.
Please contact our company amateur customer
support or the retail store where you purchased the
device as this may result in fire, electric shock and
equipment failure.
Follow the instructions given when installing
items sold separately and replacing the fuse.
This may result in fire, electric shock and equipment
failure.
Do not use the device when the alarm goes off.
For safety reasons, please pull the power plug of the
DC power equipment connected to the product out
of the AC socket.
Never touch the antenna as well. This may result
in fire, electric shock and equipment failure due to
thunder.
Do not place this device near a heating instru-
ment or in a location exposed to direct sunlight.
This may result in deformation and discoloration.
Do not place this device in a location where there
is a lot of dust and humidity.
Doing so may result in fire and equipment failure.
Stay as far away from the antenna as possible
during transmission.
Long-term exposure to electromagnetic radiation
may have a negative effect on the human body.
Do not wipe the case using thinner and benzene etc.
Please use a soft and dry piece of cloth to wipe away
the stains on the case.
Keep out of the reach of small children.
If not, this may result in injuries to children.
Do not put heavy objects on top of the power
cord and connection cables.
This may damage the power cord and connection
cables, resulting in fire and electric shock.
Do not transmit near the television and radio.
This may result in electromagnetic interference.
Do not use optional products other than those
specified by our company.
If not, this may result in equipment failure.
When using the device in a hybrid car or fu-
el-saving car, make sure to check with the car
manufacturer before using.
The device may not be able to receive transmissions
normally due to the influence of noises from the elec-
trical devices (inverters etc.) fitted in the car.
For safety reasons, switch off the power and pull
out the DC power cord connected to the DC pow-
er connector when the device is not going to be
used for a long period of time.
If not, this may result in fire and overheating.
Do not throw or subject the device to strong im-
pact forces.
This may result in equipment failure.
Do not the put this device near magnetic cards
and video tapes.
The data in the cash card and video tape etc. may
be erased.
Do not turn on the volume too high when using a
headphone or earphone.
This may result in hearing impairment.
Do not place the device on an unsteady or slop-
ing surface, or in a location where there is a lot
of vibration.
The device may fall over or drop, resulting in fire,
injury and equipment failure.
Do not stand on top of the product, and do not
place heavy objects on top or insert objects in-
side it.
If not, this may result in equipment failure.
Do not use a microphone other than those speci-
fied when connecting a microphone to the device.
If not, this may result in equipment failure.
Do not touch the heat radiating parts.
When used for a long period of time, the temperature
of the heat radiating parts will get higher, resulting in
burns when touched.
Do not open the case of the product except when replac-
ing the fuse and when installing items sold separately.
This may result in injury, electric shock and equip-
ment failure.
FTM-3207DR/DE Operating Manual
FTM-3207DR/DE Quick Reference Guide
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
LOCK
P3
P2
P1
7
1
4
8
2
0
5
9
B
A
C
D
3
6
P4
LAMP
DTMF MICROPHONE
MH-48
ABC
JKL
TUV
GHI
PQRS
DEF
MNO
WXYZ
MIC
Power Switch
Press and hold for one second.
Frequency DIAL Knob
Selects the operating Frequency.
VOL Knob
Adjusts the audio
volume level.
Microphone
Transmission Switch
Speak into the microphone in
a normal voice level while
pressing this switch.
FTM-3207DR/DE Operating Manual
Introduction
Features of this radio
430 MHz mobile radio, equipped with a C4FM communication modem
55 Watts of power output, with selection of three power levels for every operating situ-
ation
Clear audio and data communication is achieved using the C4FM modem functions
Expanded receiver coverage: 420-470 MHz
With the GD-ID (Digital Group ID) feature, the Group Monitor (GM) feature enables au-
tomatically locating, and communicating with other stations that have the same DG-ID
number within contact range, by utilizing a matching group ID number from 00 to 99.
The Digital Personal ID (DP-ID) feature supports communication specifically with
transceivers registered with the individual ID information. The DP-ID is different for
each transceiver and is included in each C4FM transmission.
Easily connect with the WIRES-X linking system
Keyboard entry of operating frequencies from the microphone
220 memories (199 “basic” memory channels, 10 sets of band-edge memory chan-
nels, and one “Home” channel) which can store repeater shifts, odd repeater shifts,
CTCSS/DCS tones, and 8-character Alpha-Numeric labels for easy channel recogni-
tion
Built-in CTCSS and DCS Encoder/Decoder circuits
Extensive Menu system, which allows customization of a number of transceiver perfor-
mance characteristics
Equipped with the GM (Group Monitor) function
Additional features include a transmit Time-Out-Timer (TOT), Automatic Power-Off (APO),
and Automatic Repeater Shift (ARS). Also included is an RF Squelch circuit that allows
the owner to set the squelch to open at a programmed setting of the S-Meter, thus reduc-
ing guesswork in setting the squelch threshold.
Congratulations on your purchase of the FTM-3207DR/DE! Whether this is your first rig,
or if Yaesu equipment is already the backbone of your station, the Yaesu organization
is committed to ensuring your enjoyment of this high-performance transceiver. It should
provide you with many years of satisfying operation. Our dealer network and technical
support personnel stand behind every product we sell, and we invite you to contact us
should you require technical advice or assistance.
We recommend that you read this manual in its entirety prior to installing the FTM-
3207DR/DE, so that you fully understand the capabilities of your new transceiver.
FTM-3207DR/DE Operating Manual
Accessories & Options
Supplied Accessories
DTMF Microphone
MH-48A6JA
Mobile Mounting Bracket
(Attachment screw set)
DC power cable w/Fuse
Operating Manual
Warranty Card
Spare fuse (25 A)
USB cable
(20 A, European version)
Optional Accessories
MH-42C6J
Microphone
MH-48A6JA
DTMF Microphone
MLS-100
High-Power External Speaker
FP-1030A
AC Power Supply (USA/EXP market only)
FTM-3207DR/DE Operating Manual
Installation
Connecting the Microphone
Connect the supplied MH-48A6JA microphone to the FTM-3207DR/DE.
Plug the microphone connector into the MIC jack on the front panel until it clicks.
Note: When disconnecting the microphone, pull the cable while pressing the connector
latch.
LOCK
P3
P2
P1
7
1
4
8
2
0
5
9
B
A
C
D
3
6
P4
LAMP
DTMF MICROPHONE
MH-48
ABC
JKL
TUV
GHI
PQRS
DEF
MNO
WXYZ
MIC
Connector
Microphone
Connecting the Antenna
Connect the coaxial cable to the body.
Plug the coaxial cable jack into the ANT terminal on the rear panel of the body, then rotate
and tighten it.
Rear panel
Coaxial cable plug
FTM-3207DR/DE Operating Manual
Mobile Installation
The FTM-3207DR/DE must only be installed in vehicles having a 13.8 Volt negative
ground electrical system. Mount the transceiver where the display, controls, and micro-
phone are easily accessible, using the supplied mounting bracket.
The transceiver may be installed in almost any location, but should not be positioned
near a heating vent nor anywhere where it might interfere with driving (either visually or
mechanically).
Make sure to provide plenty of space on all sides of the transceiver so that air can flow
freely around the radio’s case. Refer to the diagrams showing proper installation proce-
dures.
FTM-3207DR/DE Operating Manual
Power connection
To minimize voltage drop and avoid blowing the vehicle’s fuses, connect the supplied
DC power cable directly to the battery terminals. Do not attempt to defeat or bypass the
DC cable fuse - it is there to protect you, your transceiver, and your vehicle’s electrical
system.
Warning!
Never apply AC power to the power cable of the FTM-3207DR/DE, nor DC
voltage greater than 15.8 Volts. When replacing the fuse, only use a 25-A (20-A,
European version) fuse. Failure to observe these safety precautions will void
the Limited Warranty on this product.
r Before connecting the transceiver, check the voltage at the battery terminals while rev-
ving the engine. If the voltage exceeds 15 Volts, adjust the vehicle’s voltage regulator
before proceeding with installation.
r Connect the RED power cable lead to the POSITIVE (+) battery terminal, and the
BLACK power cable lead to the NEGATIVE (–) terminal. If you need to extend the
power cable, use #12 AWG or larger insulated, stranded copper wire. Solder the splice
connections carefully, and wrap the connections thoroughly with insulating electrical
tape.
r Before connecting the cable to the transceiver, verify the voltage and polarity at the
voltage at the transceiver end of the DC cable, using a DC voltmeter. Now connect the
transceiver to the DC cable.
Rear panel
Power cable
(DC 13.8 V)
Black
DC power supply
cable (supplied)
DC 12 V battery
Fuse holder
Red
Warning!
• Do not use a DC power supply cable other than the one that is supplied or
specified.
• Do not place anything on the DC power supply cable or step on it.
• Do not use the DC power supply cable with the fuse holder cut off.
• Do not reverse the polarity (positive and negative) when connecting the
battery.
FTM-3207DR/DE Operating Manual
Base Station Installation
The FTM-3207DR/DE is ideal for base station use as well as in mobile installations. The
FTM-3207DR/DE is specifically designed to integrate into your station easily, using the
following information as a reference.
AC Power Supplies
Operation of the FTM-3207DR/DE from an AC line requires a power source capable of
providing at least 20 Amps continuously at 13.8 Volts DC. The FP-1023 (USA market
only) and FP-1030A (USA/EXP market only) AC Power Supplies are available from your
Yaesu dealer to satisfy these requirements. Other well-regulated power supplies may be
used as well, if they meet the above voltage and current specifications.
Use the DC power cable supplied with the transceiver to make the power connection to
the power supply. Connect the RED power cable lead to the POSITIVE (+) power supply
terminal, and connect the BLACK power cable lead to the NEGATIVE (–) power supply
terminal.
Rear panel
Power cable
(DC 13.8 V)
Black
Direct current
power supply
AC power
outlet
DC power supply
cable (supplied)
Red
Fuse holder
FTM-3207DR/DE Operating Manual
Front Panel Controls & Switches
Front Panel
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
VOL knob
Turning the knob clockwise increases the volume, whereas turning it counterclock-
wise decreases the volume.
Mode/Status indicator
Indicates the transmission/reception status with a two-color combination on the upper
and lower portions of the mode/status indicator.
Communication status
Upper portion
Lower portion
Receiving analog audio
Green
Green
Transmitting analog audio
Red
Red
Receiving digital audio
Green
Blue
Transmitting digital audio
Red
Blue
Receiving digital data
Green
White
Transmitting digital data
Red
White
Receiving signals with unmatched
audio or data conditionsø
Green
Blink in Blue
ø • Receiving signals with unmatched tone frequency or DCS code.
• Receiving analog audio in digital mode.
• Receiving signals with unmatched SQL code in digital mode.
• Receiving a signal level less than the RF Squelch S-meter level setting.
DIAL Knob
• Allows setting the operating band frequency.
Turning clockwise increases the frequency, whereas turning counterclockwise de-
creases the frequency.
• Allows selecting the desired items for setup, memory registration, group monitoring
operation, etc.
MIC Jack
Connect the provided microphone cable.
Front Panel Controls & Switches
FTM-3207DR/DE Operating Manual
[SQL(TXPO)] key
Press and hold the key in for over one second to select the transmit power (HIGH: 55
W / MID: 25 W / LOW: 5 W).
[REV(DW)] key
During split-frequency operation, such as through a repeater, this key reverses the
transmit and receive frequencies.
Press and hold the key in for over one second to activate the Dual Watch feature.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
[D/A(GM)] key
Briefly pressing each time switches the operating band communication mode.
Press and hold in this key for over one second to activate the GM (Group Monitor)
function.
Note: For details on the GM function, see “GM (Group Monitor) Function” on 34
[MHz(SETUP)] key
This key allows tuning in 1 MHz steps (the MHz digits will blink on the display).
Press and hold this key in for over one second to activate the Setup (Menu) Mode.
[V/M(MW)] key
Pressing this key briefly, switches between VFO mode and memory mode. Press and
hold the key for over one second to display the memory registration screen.
Power/Lock key
Press and hold in this key for over one second to switch the power between ON and OFF.
Briefly pressing the key while the transceiver is turned ON engages or releases the key
lock.
Speaker
The internal speaker is located here.
LCD Display
The main digits on the display may show the operating frequency, memory name, or
any of many parameters during Menu setup.
S and TX Power Meter
Communication mode
Lock Feature Active
DTMF Memory Mode
SKIP/Preferential Scan Channel
Narrow Deviation
LOW/MID TX Power Selected
Memory mode
Memory Channel Number
GM Feature Communica-
tion range indicator
AMS Function
GM Feature Active
Frequency/Message
Area
HOME Channel
CTCSS/DCS/EPCS Bell Paging
CTCSS
(Continuous Tone Coded Squelch System)
DCS (Digital Code Squelch)
Repeater Shift Direction
FTM-3207DR/DE Operating Manual
Microphone Switches
Microphone (MH-48A6JA)
PTT Switch
Press this switch to transmit, and release
it to receive.
KEY Pad
These 16 keys generate DTMF tones during
transmission.
In the receive mode, these 16 keys can be
used for direct frequency entry and/or direct
numeric recall of the Memory channels.
[P1] / [P2] keys
[P1] button
Press this button to recall the DG-ID memory.
[P2] button
Press and hold this button to enter the
DGID memory screen.
LOCK
P3
P2
P1
7
1
4
8
2
0
5
9
B
A
C
D
3
6
P4
LAMP
DTMF MICROPHONE
MH-48
ABC
JKL
TUV
GHI
PQRS
DEF
MNO
WXYZ
MIC
[P3] / [P4] keys
These two keys are user programmable, allowing quick access to features used often.
The default functions are described below.
[P3] button (Wires-X)
Press this button to activate the Wires-X feature.
[P4] button (TX PW/T.CALL)
In the USA version, pressing this button activates TX power setting.
In the EXP/European version, pressing this button activates T.CALL (1750 Hz) for
repeater access.
You can reprogram the [P3], and [P4] buttons for other functions, if desired.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
MIC
Speak into this port during transmission.
[UP] / [DWN] keys
Press (or hold in) either of these buttons to tune (or scan up or down) the operating
frequency or through the memory channels. In many ways, these buttons emulate the
function of the (rotary) DIAL knob.
LOCK switch
This switch locks out the Microphone buttons (except for the keypad and PTT switch).
LAMP switch
This switch illuminates the Microphone keypad.
FTM-3207DR/DE Operating Manual
Rear Panel Connectors
Rear Panel
ANT Coaxial Socket
Connect a 430 MHz antenna to this type-M (SO-239) socket using 50-Ohm coaxial
cable and a type-M (PL-259) plug. Make sure the antenna is designed specifically for
use on the operating frequency.
EXT SP Jack
This 2-contact 3.5-mm mini phone jack provides receiver audio output for an optional
external speaker. The audio impedance is 4 Ohms, and the level varies according to
the setting of the front panel VOL control. Inserting a plug into this jack disables audio
from the transceiver’s internal speaker.
13.8 V DC Cable
Connect the provided DC power supply cable (with fuse attached).
DATA Jack
Use this jack when updating the firmware. When a new firmware update for the FTM-
3207DR/DE is available, go to the YAESU website to download the programming data
and update the FTM-3207DR/DE to its newest state.
Cooling Fan
FTM-3207DR/DE Operating Manual
Basic Operation
Turning the Transceiver ON and OFF
1. To turn the transceiver ON, press and hold
the PWR/LOCK key for one second.
2. To turn the transceiver OFF, again press and
hold the PWR/LOCK key for one second.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
You can compose any desired Opening Message (up to 8 characters) via Setup Menu
Item “OPEN MSG 27” see 43 for details.
Inputting the call sign
A screen requesting input of a call sign appears when turning the transceiver on for the
first time, or after resetting the transceiver. The call sign is used to identify the transmit-
ting station when communicating in digital mode.
1. Press the [V/M(MW)] key.
2. Rotate the DIAL knob to select characters,
then press the [V/M(MW)].
By rotating the DIAL knob, you can switch
the characters in the following order:
“space” à “-” à “/” à “0” to “9” à “A” to “Z”
r Up to 10 characters (alphanumeric characters including hyphen) can be entered.
r “space”, “-”, and “/” are not selectable for the first character.
3. Press and hold the [MHz(SETUP)] key for one second to save the call sign and exit to
normal operation.
Adjusting the Audio Volume Level
Rotate the VOL knob to adjust the receiver
volume. Clock-wise rotation increases the audio
output level.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Adjusting the Squelch Setting
1. Press the [SQL(TXPO)] key, then rotate the
DAIL knob to select the Squelch level.
2. Press the [SQL(TXPO)] key again.
Note: A special “RF Squelch” feature is pro-
vided on this radio. This feature al-
lows setting the squelch so that only
signals exceeding a certain S-meter
level will open the squelch. For de-
tails, refer to the Advanced Manual
(download from the Yaesu website).
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
FTM-3207DR/DE Operating Manual
Frequency Navigation
Using the Dial
Rotating the DIAL knob allows tuning in the
pre-programmed steps. Clockwise rotation
tunes the frequency upwards, whereas coun-
terclockwise rotation tunes the frequency
downwards.
r Press the [MHz(SETUP)] key momentarily,
then rotate the DIAL knob, to change the fre-
quency steps to 1 MHz per step.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Using the MH-48A6JA Microphone
Using the [UP] and [DWN] key:
Pressing [UP] momentarily, tunes the frequen-
cy upwards. Whereas pressing [DWN] mo-
mentarily tunes the frequency in the downward
direction.
Using the number keys:
Use the [0] to [9] number keys to directly input
the frequency.
There is no “decimal point” key on the MH-
48A6JA keypad. However, there is a short-cut
for frequencies ending in zero:
press the [#] key after the last non-zero digit.
UP
DWN
Number
keys
Examples: To enter 446.520 MHz, press [4] à [4] à [6] à [5] à [2] à [0]
To enter 446.000 MHz, press [4] à [4] à [6] à [#]
Channel Step Selection
The frequency tuning step of the DIAL and the microphone [UP]/[DWN] keys can be
changed.
Note: See Setup Menu Item “STEP 41” on 44
FTM-3207DR/DE Operating Manual
Selecting the communication mode
The FTM-3207DR/DE transceiver is equipped with the AMS (Automatic Mode Select)
function which automatically selects from two modes of transmission corresponding to
the signal being received.
The transmit mode is selected according to the received signal so that C4FM digital sig-
nals, and analog signals are received and transmitted automatically.
Press [D/A(GM)] key to display “
” (blinks) icon on the screen.
Display example when in AMS mode
AMS transmission mode
To operate in fixed communication mode, press [D/A(GM)] key to switch the communi-
cation mode.
Each time [D/A(GM)] key is pressed, the communication mode changes in the following
order:
à AMS (“
” blinks) à V/D (“
” lights up) à FM (no icon) à
Communication mode
Icon
Description of modes
AMS (Automatic Mode Select)
(blinks)
Transmit mode is automatically selected from 3
types according to the signal received.
The AMS function operation can be changed
from the Setup menu setting. See “Setting the
transmit mode when using the AMS function
(DIG AMS 12)” on 42
V/D Mode
(Voice/Data simultaneous
transmission mode)
(light up)
Calls are less prone to interruptions due to de-
tection and correction of voice signals during
digital voice signal transmission. This is the
standard mode for C4FM Digital.
Analog FM Mode
no icon
Analog communication using FM mode.
Effective when the signal is weak and audio is
susceptible to interruption in digital mode.
FTM-3207DR/DE Operating Manual
Setting the transmission mode when using the AMS function
TXMANUAL (“
” blinks: 1 sec on, 0.5 sec off)
Automatically selects one of the two communication modes according to the received
signal. Briefly pressing [PTT] on the microphone switches between digital mode and
analog mode.
Blinks: 1 sec on, 0.5 sec off
D: DN mode
F: FM mode
TX FMFIX (“
” blinks: 0.5 sec on, 0.5 sec off)
Automatically selects one of the two communication modes according to the received
signal. Always switches to FM mode for transmission.
Blinks: 0.5 sec on, 0.5 sec off
FM mode
TX DNFIX (“
” blinks: 0.5 sec on, 0.5 sec off)
Automatically selects one of the two communication modes according to the received
signal. Always switches to DN mode for transmission.
Blinks: 0.5 sec on, 0.5 sec off
DN mode
AUTO (“
” blinks: 0.5 sec of, 0.5 sec off)
Automatically selects one of the two communication modes according to the received
signal.
Blinks: 0.5 sec on, 0.5 sec off
D: DN mode
F: FM mode
FTM-3207DR/DE Operating Manual
Transmission
1. Press and hold PTT on the microphone.
In analog mode, both the upper and lower
portions of the PTT mode/status indicator
light red.
In digital mode, the upper portion of the
mode/status indicator lights red and the low-
er portion of the mode/status indicator lights
blue.
LOCK
P3
P2
P1
7
1
4
8
2
0
5
9
B
A
C
D
3
6
P4
LAMP
DTMF MICROPHONE
MH-48
ABC
JKL
TUV
GHI
PQRS
DEF
MNO
WXYZ
MIC
MIC
PTT
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Analog mode: Both the upper and lower portions light red
Digital mode: The upper portion lights red and the lower portion lights blue
2. Speak into MIC on the microphone.
Note: Keep the microphone about 5 cm away from your mouth.
The sensitivity (gain) of the microphone can be adjusted. For details, refer to the
Advanced Manual (download from the Yaesu website).
3. Release PTT.
The transmit mode/status indicator turns off and the transceiver returns to the receive
mode.
Caution: Do not continue transmitting for a prolonged period. The transceiver may
overheat, resulting in malfunction or injury.
Note: “ERROR” appears if you attempt to transmit on an unavailable frequency.
FTM-3207DR/DE Operating Manual
Adjusting the transmit power
When communicating with a nearby station, the transmit power level may be lowered to
reduce the battery power consumption.
1. Press and hold the [SQL(TXPO)] key for
over one second.
2. Rotate the DIAL to select the transmit pow-
er.
Note: The default setting: HIGH
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
HIGH (55 W)
MID (25 W)
LOW (5 W)
3. Press the [SQL(TXPO)] key to save the new setting and exit to normal operation.
Lock Feature
To activate the key-lock feature, press the
[Power(Lock)] key. The “
” icon will appear
on the LCD.
To cancel key-lock, press the [Power(Lock)]
key again.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
To select which keys are locked, use the Setup Menu Item “LOCK 23” see 43 for de-
tails.
FTM-3207DR/DE Operating Manual
Advanced Operation
About the Digital Group ID (DG-ID) feature
The DG-ID function can set up two-digit DG-ID numbers from “00” to “99” separately for
Transmit and Receive. By setting both transmit and receive to “00” (default), you can
communicate with all the other stations in the digital C4FM mode.
By matching the transmit DG-ID number to the uplink DG-ID number set in the club DR-
2X/XE System Fusion II digital repeater, you can access the digital repeater DR-2X/XE
used in the club.
For communication only among a group of friend’s transceivers, you can all match the
same DG-ID number; then only your friend’s voices will be heard. Also, by using the GM
function you can check whether stations with the same DG-ID are in the communication
range. The FTM-3207DR/DE may register transmit and receive DG-ID numbers in the
DG-ID memories (up to 10 pairs), and then use the [P1] / [P2] keys on the microphone to
easily recall a Group ID.
Register the DG-ID number in the DG-ID memory
Example:
Enter the transmit DG-ID number “50” and the receive DG-ID number “00”
into the DG-ID memory “01”
1. Press and hold the [P2] key on the microphone.
The DG-ID memory number at the bottom
right of the screen blinks.
2. Rotate the DIAL knob to select the DG-ID
memory number to be stored to the “01”
register.
3. Press the [P2] key on the microphone.
The transmit DG-ID number “T00” blinks.
4. Rotate the DIAL knob to set the transmit
DG-ID number to “T50”.
5. Press the [P2] key on the microphone.
The transmit DG-ID number blinks.
6. Rotate the DIAL knob to set the receive
DG-ID to “R00”.
7. Press the [P2] key on the microphone.
• The input screen of the DG-ID tag is
displayed.
FTM-3207DR/DE Operating Manual
• Use the numeric keys on the microphone
or the DIAL knob to input the characters
of the DG-ID tag. Up to 8 characters can
be entered.
Press the [P3] key on the microphone or
[SQL (TXPO)] key to move the cursor to
the left.
Press the [P4] key on the microphone or
[V/M (MW)] key to move the cursor to the
right.
8. Press and hold the [P2] key on the
microphone to save the setting and return
to normal operation.
Notes:
z
z The DG-ID memory “00” is fixed at “T00 R00”
and cannot be changed.
z
z By pressing and holding the [P2] key on the
microphone in the middle of the setting, the
setting so far will write and then return to the
normal screen.
z
z When the [P2] key on the microphone is not
pressed while writing, after five seconds
elapse the operation will return to the normal
screen without saving the setting.
Recall and use the DG-ID number registered in the DG-ID memory
1. Press the [P1] key on the microphone,
the information of the current DG-ID is
displayed.
2. Rotate the DIAL knob to select the number
of DG-ID List to recall.
3. Press the PTT button to select the DG-
ID number and return to the frequency
display screen. Or if five seconds passes,
the selected screen will return to frequency
screen automatically.
• When using the DG-ID memory, the
tag of the DG-ID memory being used is
displayed every 5 seconds.
• If the DG-ID memory is “00”, DG-ID
memory tag is not displayed.
DG-ID Tag display
DG-ID Number display
FTM-3207DR/DE Operating Manual
4. Press the [P1] key on the microphone to
switch to the DG-ID number display as
shown below. When the DG-ID memory is
"00", no DG-ID tag is displayed, only the
DG-ID number "00" is displayed.
DG-ID Tag display
DG-ID Number display
Normal Screen
• If there is no operation for more than five
seconds, the display returns to the normal
frequency display screen.
Normal Screen (Frequency)
Normal Screen (DG-ID Tag)
Restore the DG-ID number to “00” for both transmit and receive without using the DG-ID memory
1. Press and hold the [P1] key on the microphone while on the frequency display screen.
The DG-ID memory returns to DG-ID memory “00” with one touch.
Use the GM (Group Monitor) with the DG-ID function
1. Press and hold the [D/A(GM)] key to turn
the GM (Group Monitor) function ON, then
you can check whether or not other Group
Member stations are operating within
communications range.
• The “GM” icon is displayed at the upper
left of the display.
• The other stations also need to turn the GM
function ON.
• While operating in the GM function, the call
sign of a maximum 24 stations turned the
GM function ON, and that are within the
communication range, may be checked.
• Rotate the DIAL knob to select the other
stations.
2. Press and hold the [D/A(GM)] key to turn the GM (Group Monitor) function OFF.
Notes:
z
z The DG-ID memory “00” is fixed at “T00 R00” and can not be changed.
z
z If the DG-ID memory is “00”, DG-ID memory tag is not displayed every 5 seconds.
z
z If the receive DG-ID number is set to other than “00”, note that you cannot receive signals other
than the same DG-ID number.
FTM-3207DR/DE Operating Manual
Digital Personal ID (DP-ID) feature
Every C4FM digital transmit communication contains the individual ID information (Radio
ID) of each transceiver. The DP-ID function uses this individual ID information.
When communicating with another transceiver, if the DP-ID of the stations are registered
in each other‘s transceivers, they can communicate even if the DG-ID numbers are
different.
Registering the DP-ID to a DR-2X digital repeater
Note: To register the transceiver DP-ID in the System Fusion II, DR-2X C4FM digital repeater, refer to
the instruction manual of the DR-2X.
By registering the transceiver’s DP-ID in the DR-2X, you can remotely control the settings
and functions of DR-2X. Remote control cannot be performed from a transceiver that
does not register the DP-ID, so it is possible to securely manage repeaters.
DR-2X Remote Control Feature
• Activate the repeater operation
• Deactivate the repeater operation
• Set the repeater to C4FM mode
• Set the transmit power
• Voice Message Control (Rec / Play / Stop)
• Set the Emergency Call
Register the transceivers
1. Press and hold the [MHz(SETUP)] key to
enter the Setup Menu.
2. Rotate DIAL knob to select “DPID LST 14”.
3. Press the [MHz(SETUP)] key.
The DP-ID List is displayed.
4. While the DP-ID list is displayed, a
transmission in the digital C4FM mode
from the other transceiver will register the
DP-ID.
When a signal from the other station is
received, the call sign is displayed on the LCD.
Notes:
z
z When a signal from the already registered transceiver is received, the display of DP-ID list does
not change.
z
z When registering a transceiver already registered with a different call sign, the call sign registered
in the DP-ID list is changed to registrar the new call sign.
FTM-3207DR/DE Operating Manual
5. Press and hold the [D/A(GM)] key to save
the setting.
• When registering in the DP-ID list is
finished, “Completed” is displayed, then the
display returns to the DP-ID list screen.
• To continue operating without registering
the DP-ID, press the [D/A(GM)] key.
• If registering several DP-IDs, repeat steps 4 to 5.
• A maximum of 24 stations may be registered.
6. Press and hold the [MHz(SETUP)] key to return to normal operation.
Register the DP-ID of all the transceivers in the group to another transceiver using
the same operation.
Notes:
z
z Once the DP-ID is registered, the DP-ID is stored until the DG-ID is deleted.
z
z Register with the another transceiver while each other’s transceivers are nearby.
Deleting the registered DP-ID
1. Press and hold the [MHz(SETUP)] key to
enter the Setup Menu.
2. Rotate DIAL knob to select “DPID LST 14”.
3. Press the [MHz(SETUP)] key.
The DP-ID List is displayed.
4. Rotate the DIAL knob to select the call sign.
5. Press and hold the [D/A(GM)] key
The confirmation screen is displayed.
6. Press and hold the [D/A(GM)] key again to
delete.
• When deleting in the DP-ID list is finished,
“COMPLETE” is displayed for three
seconds, then the display returns to the
DP-ID list screen.
• To return to normal operation without deleting
the DP-ID, press the [D/A(GM)] key.
• If deleting several DP-IDs, repeat steps 4 to 6.
7. Press and hold the [MHz(SETUP)] key to
return to normal operation.
FTM-3207DR/DE Operating Manual
Advanced Operation
Repeater Operation
The FTM-3207DR/DE includes the ARS (Automatic Repeater Shift) function, which per-
mits communication through repeaters automatically, by simply setting the receiver to the
repeater frequency.
1. Tune to the repeater frequency.
2. Press the PTT to transmit.
During transmission, radio waves having an 100.0 Hz* tone signal are emitted on the
frequency offset from the receive frequency by 5.0 MHz*.
*: Depends on the transceiver version.
Note: From the Setup Menu, you can change the repeater setting.
RPT ARS 34 à Deactivates the ARS function.
RPT FREQ 35 à Allows changing the repeater shift frequency offset.
RPT SFT 36
à Allows setting the repeater shift direction.
Checking the Repeater Uplink (Input) Frequency
It is often helpful to be able to check the uplink (input) frequency of a repeater, to see if
the calling station is within direct (“Simplex”) range.
To do this, just press the [REV(DW)] key. You’ll
notice that the display has shifted to the repeat-
er uplink frequency. Press the [REV(DW)] key
again to cause operation to revert to normal
monitoring of the repeater downlink (output)
frequency. While listening on the repeater input
frequency using the [REV(DW)] key, the repeat-
er offset icon will blink.
Blinks
Tone Calling (1750 Hz)
If your transceiver is FTM-3207DE (European version), press and hold in the program
key [P4] of the microphone (MH-48) to generates a 1750 Hz burst tone to access the
European repeater. The transmitter will automatically be activated, and a 1750 Hz audio
tone will be superimposed on the carrier. Once access to the repeater has been gained,
you may release the [P4] key, and use the PTT for activating the transmitter thereafter.
FTM-3207DR/DE Operating Manual
CTCSS Operation
This radio is equipped with the CTCSS (Continuous Tone-coded Squelch System) that
allows audio to be heard only when receiving signals containing a tone corresponding to
the tone squelch menu setting. By matching the CTCSS tone with the partner station in
advance, quiet standby monitoring is possible.
Caution: CTCSS does not function in digital mode. To transmit a signal using a CTCSS
code, use the [D/A(GM)] key to switch the communication mode to AMS (Auto
Mode Select function) or analog (FM) mode.
1. Press and hold the [MHz(SETUP)] key for over one second.
The Setup menu appears.
2. Rotate the DIAL knob to select “SQL TYPE 40”, then press the [MHz(SETUP)] key.
3. Rotate the DIAL knob to select “TSQL”, then
press and hold the [MHz(SETUP)] key for
over one second.
“
” is displayed on the screen. Now the squelch opens only when receiving tone
signals of the set frequency.
Note: From the Setup Menu, you can change the CTCSS setting.
TONE FRQ 43 à The tone frequency can be selected from 50 frequencies.
BELL 7
à A bell tone (beep) may be set to sound when signals containing
a corresponding CTCSS tone are received.
Tone Search
When the CTCSS tone being transmitted by another station is not known, you can tune
the radio to the incoming signal and activate tone scan to search for and identify the tone
being used.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
DCS Operation
This radio is equipped with a DCS (Digital Coded Squelch) function that allows audio to
be heard only when signals containing the corresponding DCS code are received. By
matching the DCS code with the partner stations beforehand, a quiet receive standby is
possible.
Caution: DCS does not function in digital mode. To transmit a signal with a DCS code,
use the [D/A(GM)] key to switch the communication mode to AMS (Auto Mode
Select function) or analog (FM) mode.
1. Press and hold the [MHz(SETUP)] key for over one second.
The Setup menu appears.
2. Rotate the DIAL knob to select “SQL TYPE 40”, then press the [MHz(SETUP)] key.
FTM-3207DR/DE Operating Manual
3. Rotate the DIAL knob to select “DCS”, then
press and hold the [MHz(SETUP)] key for
over one second.
Displays “
” on the screen. The squelch opens only when receiving a signal con-
taining the corresponding DCS code.
Note: From the Setup Menu, you can change the DCS setting.
DCS CODE 10 à The DCS code can be selected from 104 codes.
BELL 7
à A bell tone (beep) may be set to sound when signals containing
a corresponding DCS code are received.
DCS Search
When the DCS code being transmitted by another station is not known, you can tune the
radio to the incoming signal and activate DCS code scan to search for and identify the
DCS code being used.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
The following features are also available:
EPCS (Enhanced Paging & Code Squelch) Operation
Use the pager code consisting of two CTCSS tones to exchange communications with
specified stations.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Split Tone Operation
The FTM-3207DR/DE can be operated in a “Split Tone” configuration that enables opera-
tion on repeaters using a mix of both CTCSS and DCS control via the Setup menu.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
DTMF Operation
DTMF tones (Dual Tone Multi Frequencies) are the tones you hear when dialing from a
telephone keypad. The FTM-3207DR/DE transceiver can transmit the DTMF codes by
using the keys on the microphone or recalling registered number strings from memories.
The maximum of 16-digit DTMF codes can be registered in up to 10 memory channels.
It is convenient to register telephone patch numbers, and network linking sequences to
the DTMF memory channels.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
Memory Operation
The FTM-3207DR/DE provides a wide variety of memory system resources. These in-
clude:
r 199 “basic” memory channels, numbered “1” through “199”.
r A “Home” channel, providing storage and quick recall of one prime frequency.
r 10 sets of band-edge memories, also known as “Programmable Memory Scan” chan-
nels, labeled “L0/U0” through “L9/U9”.
Each memory may be appended with an alphanumeric label of up to 8 characters, for
quick channel recognition.
Memory Storage
1. In the VFO mode, select the desired frequency, repeater shift, CTCSS/DCS tone, and
TX power level.
2. Press and hold the [V/M(MW)] key for one
second.
A memory number will appear in the bottom
right corner of the display.
Note: If the channel number is blinking,
there currently is no data stored on
that channel; if the channel number is
not blinking, that channel is currently
“occupied” by other frequency data.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
3. Within five seconds of pressing the [V/M(MW)] key, use the DIAL knob to select the
desired memory into which you wish to store the frequency.
Note: While operating in the Memory Storage mode, the keypad of the MH-48A6JA
Microphone may be used to enter the memory channel number directly.
To do this, enter the desired Channel Number on the keypad and then press the
[#] key. Refer to the “For example” of the “Memory Recall from the Microphone
Keypad“ on next page.
4. Press the [V/M(MW)] key again, this time momentarily, to store the displayed data into
the selected memory channel slot.
5. To store additional frequencies, repeat steps 1 through 4, remembering to set the re-
peater shift, CTCSS/DCS tone, and TX power level, as appropriate.
Split Memory
A separate transmit frequency may be registered to a memory channel to which a receive
frequency has already been registered.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Naming a Memory Channel
You may also append an alphanumeric “Tag” (label) to each memory, to aid in recollection
of the channel’s use (such as club name, etc.).
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
Memory Recall
Once the desired frequencies are stored into memory channels, switch from the “VFO”
mode to the “Memory Recall” mode, to operate on the just-stored memory channels.
1. Press the [V/M(MW)] key, repeatedly if nec-
essary, until the “
” icon and a memory
channel number appear on the display; this
indicates that the “Memory Recall” mode is
now engaged.
2. When more than one memory has been
stored, use the DIAL knob to select any of
the programmed memories for operation.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Note: Alternatively, the microphone [UP] or [DWN] button may be used to step or scan
through the available memories. When using the microphone buttons, press the
button momentarily to move one step up or down; press and hold the [UP] or
[DWN] button for one second to begin memory scanning.
Memory Recall from the Microphone Keypad
While operating in the Memory Recall mode, the keypad of the MH-48A6JA Microphone
may be used for direct recall of memory channels.
To do this, enter the desired Channel Number on the keypad and then press the [#] key.
For example:
To recall Memory Channel “5”, press [5] à [#]
To recall Memory Channel “123”, press [1] à [2] à [3] à [#]
You may also recall Programmable Memory Scan (PMS) channels (“L0/U0” through “L9/
U9”) by entering the channel numbers listed in the below table:
L1
201
L3
205
L5
209
L7
213
L9
217
U1
202
U3
206
U5
210
U7
214
U9
218
L2
203
L4
207
L6
211
L8
215
L0
219
U2
204
U4
208
U6
212
U8
216
U0
220
Moving Memory Data to the VFO
Data stored on memory channels can easily be moved to the VFO.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Memory Only Mode
Once memory channel programming has been completed, you may place the radio in a
“Memory Only” mode, whereby VFO operation is impossible.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
Masking Memories
There may be situations where you want to “Mask” memories so they are not visible
during memory selection or scanning. (except for Memory Channel “1”, the Priority Chan-
nel, and the Home Channel).
1. In the Memory Recall mode, press and hold
the [V/M(MW)] key for one second, then
rotate the DIAL knob to select the memory
channel you wish to mask.
2. Press the [SQL(TXPO)] key.
The erase confirmation screen appears.
3. Press the [SQL(TXPO)] key.
The previously selected memory will be
“masked”.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Note: Press any key, other than [SQL(TXPO)], to cancel the memory mask.
Unmasking Memories
1. To Unmask a hidden memory, in the Memory Recall mode, press and hold the
[V/M(MW)] key for one second.
2. Rotate the DIAL knob to select the masked memory number.
3. Press the [SQL(TXPO)] key to restore the memory channel data.
HOME Channel Memory
A convenient one-touch “Home” channel memory is available to simplify returning to an
often used frequency.
To recall the Home channel, just press the
[V/M(MW)] key, repeatedly if necessary, until
the “
” icon appears on the display; this
indicates that the Home Channel has been
recalled.
Note: When shipped from the factory, the
Home Channel is set to 446.000 MHz
(USA version) or 433.000 MHz (EXP/
European version).
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Changing the frequency of the home channel
The default frequency setting of the home channel can be changed.
1. In the VFO mode, tune to the desired Home channel frequency.
2. Press and hold the [V/M(MW)] key for one second, and then press the [REV(DW)] key.
The overwrite confirmation screen appears.
3. Press the [REV(DW)] key.
The home channel frequency is overwritten.
FTM-3207DR/DE Operating Manual
Scanning
Basic Scanner Operation
Before activating the scanner, make sure that the Squelch is set to silence the back-
ground noise when no signal is present. Scanning is not possible while the Squelch is
open (if noise or signals are being heard).
Scanning may be started or stopped using the micro-
phone [UP] or [DWN] button.
The following techniques are used for scanning:
r in the VFO mode, press and hold either the [UP]
or [DWN] button for one second, to start upward or
downward scanning of the band.
r In the Memory mode, press and hold either the
[UP] or [DWN] button for one second to start chan-
nel scanning toward a higher or lower-numbered
memory channel, respectively.
LOCK
P3
P2
P1
7
1
4
8
2
0
5
9
B
A
C
D
3
6
P4
LAMP
DTMF MICROPHONE
MH-48
ABC
JKL
TUV
GHI
PQRS
DEF
MNO
WXYZ
MIC
DWN
UP
r Scanning pauses when a signal opens the squelch, and the decimal point on the dis-
play will blink. You can choose one of three scan-resume modes (described later).
r To halt the scan manually, the easiest way is to push the PTT switch on the microphone
momentarily (no transmission will occur while you are scanning). The scan may also be
halted manually by pressing the microphone [UP] or [DWN] button, or the [V/M(MW)] key.
Scan Resume Options
Select which of the three resume scan modes is to be performed after the scanning stops.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Memory Skip Scanning
Memory channels which you do not want to receive can be skipped during scanning.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Preferential Memory Scan
Set up a “Preferential Scan List” of channels which you can “flag” within the memory system.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Programmable Memory Scan (PMS)
Using the dedicated PMS memory channels, only the frequencies within the specified
frequency range will be scanned.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Priority Channel Scanning (Dual Watch)
Scanning features include a two-channel scanning capability which allows you to operate
on a VFO, Memory channel, or Home channel, while periodically checking a user defined
Memory Channel for activity.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
GM Function
What is the GM (Group Monitor) Function?
The GM function automatically monitors the channel for any other stations with the GM
function in operation on the same frequency, or stations transmitting in DN mode that are
within communication range. You can be notified of GM stations operating within com-
munications range, and the detected call signs are displayed on the transceiver screen,
Caution: The GM function does not work while in the analog (FM) mode.
à
Displaying all the stations using the GM function
1. Tune to the designated frequency.
2. Press and hold the [D/A(GM)] key for one
second.
The GM function is activated, and up to 24
stations using the GM mode, or stations op-
erating in DN mode on the channel frequen-
cy, within the communication range are dis-
played
r Displays “
” for stations within your
communication range.
r Displays “
” (blinks) for stations out-
side of your communication range.
r Turn the DIAL knob to select a station
and display its communication range in-
formation.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
3. Press and hold the [D/A(GM)] key for one second to disable the GM function and re-
turn to the frequency screen.
FTM-3207DR/DE Operating Manual
Reset Procedure/Clone
Reset Procedure
In some instances of erratic or unpredictable operation, the cause may be corruption of
data in the microprocessor (due to static electricity, etc.). If this happens, resetting the
microprocessor may restore normal operation. Note that all memories will be erased if
you do a complete microprocessor reset, as described below.
Microprocessor Resetting
To clear all memories and other settings to factory defaults:
1. Turn the radio OFF.
2. Press and hold the [D/A(GM)], [MHz(SETUP)], and [V/M(MW)] keys while turning the
radio on. The “ALL RESET PUSH V/M KEY” notation will scroll on the display.
3. Press the [V/M(MW)] key momentarily to reset all settings to their factory defaults
(press any other key to cancel the Reset procedure).
Setup (Menu) Mode Resetting
To reset the Setup (Menu) Mode settings to their factory defaults, while leaving other
settings unchanged:
1. Turn the radio OFF.
2. Press and hold the [D/A(GM)] and [MHz(SETUP)] keys while turning the radio on. The
“SET MODE RESET PUSH V/M KEY” notation will scroll on the display.
3. Press the [V/M(MW)] key momentarily to reset the Setup (Menu) Mode settings to their
factory defaults (press any other key to cancel the Reset procedure).
Clone
The FTM-3207DR/DE includes a convenient “Clone” feature, which allows the memory
and configuration data from one transceiver to be transferred to another FTM-3207DR/
DE.
This can be particularly useful when configuring a number of transceivers for a public
service operation.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
Connecting the WIRES-X feature
What is WIRES-X?
WIRES-X is an Internet communication system which expands the range of amateur
radio communication. You may employ Internet communications by connecting from your
transceiver to a WIRES-X local node station.
*FTM-3207DR/DE does not accommodate the transmission/reception of messages,
images, audio messages, or location information.
Connecting to a WIRES-X digital node (Recommended)
*Ascertain the DSQ code or the DG-ID setting of the WIRES-X node station. Connecting
to the WIRES-X node requires the transceiver DG-ID be set according to the DSQ code
or the DG-ID code set on the WIRES-X node station.
*Confirm that the operating mode of WIRES-X node has been set to the C4FM digital
mode.
1. Set the transmit/receive DG-ID to the same ID number as the node station.
For more details on the DG-ID number, see page 22
2. Transmit on the corresponding transmit/receive frequency.
• If the signal is received from the node, continue to transmit using the DGID setting
as is.
• If the signal is not received from the node. à proceed to “Connecting to the other
node ID or the other room ID”
Connecting to the other node ID or the other room ID
1. Press and hold the [MHz(SETUP)] key to enter the Setup Menu.
2. Rotate the DIAL knob to select “W-DGID 49”, then press the [MHz(SETUP)] key.
3. Rotate the DIAL knob to set the WIRES-X DG-ID to the same ID number as the node
station.
Display
Description
DGID01-99
Only nodes matching the set DG-ID number may be connected.
AUTO
(default setting) Only open nodes, set to the DG-ID number "00" may be connected.
4. Press the PTT switch, or press and hold the [MHz(SETUP)] key to save the new setting
and return to normal operation.
5. Press the [P3] key.
“WIRES“ blinks.
Connecting the WIRES-X feature
FTM-3207DR/DE Operating Manual
After successfully connecting to the node, one of the following screens is displayed
indicating the node status.
r 1.Node ID screen (the Node Lc screen)
• This screen is displayed if the node is
disconnected from the other node or the
room on the Internet.
• The node station’s node ID is displayed.
• Continue to select a connecting node à proceed to step 6
r 2.Connecting to a node ID or room ID-
screen (the Cn screen)
• This screen is displayed when the node
has been connected to a node or room
on the Internet.
• The connecting node station’s node ID is displayed.
• If not changing the connecting node/room à proceed to step 7
• When changing the connecting node/room à proceed to step 6
Note:If the node connection is not successful, the beep sound is emitted and the transceiver
returns to the normal operation.
6. Rotate the DIAL knob to select one of the connection screens (see below information),
and connect to the desired node/room.
Node ID screen
(the Node Lc screen)
Connecting to the node ID or
room ID screen (the Cn screen)
The most recent connected node ID
or room ID screen (the C0 screen)
Registered node ID or room ID
screen (the C1 - C5 screen)
Direct entry screen
(the En screen)
r The most recent connected node ID or
room ID screen (the C0 screen)
Most recent connected node ID or room
ID is displayed. A single press of the [#]
key on this screen will connect to the
most recent node/room.
r Registered node ID or room ID screen
(the C1-C5 screen)
Rotate the DIAL knob to select a previ-
ously registered node/room (maximum 5
nodes/rooms) on the C1-C5 screen and,
then press the [#] key or the PTT switch to
connect to the node/room.
Connecting the WIRES-X feature
FTM-3207DR/DE Operating Manual
• Registering the node/room: Press and hold the [1]-[5] key to register the node/room
(C1-C5) on the connected node ID or room ID (Cn).
• Cancelling the connected node/room: Select the node/room (C1-C5) then
press and hold the [C] key to delete the
registered node/room.
r Direct entry screen (En)
Direct connection to a node or room may
be made by inputting the other node ID
or room ID (5 digits) manually.
• Pressing the numeric keys (5 digits), and then press the [#] key, will request con-
nection with another node ID or room ID.
• Clearing the input node ID or room ID: Press and hold the [C] key
• Cancelling the input node ID or room ID: Pressing the [*] key to return to the
node ID screen (Lc) or the connecting
node ID or room ID screen.
Note: When a node has been connected, the node or room connection may be
changed by inputting a different node ID or room ID.
When connecting to a node or room,
"CONNECT" is displayed on the screen, and
the display is automatically switched to the
connecting node ID or room ID screen (Cn).
Note: In the case when the selected node or room is not connected, the screen will
display one of the below icons.
“OFFLINE” (Node or room is not in operation.)
”BUSY” (Another node is connecting.)
7.Transmit to communicate with the WIRES-X Internet Link.
Note: Operations of the microphone [#], PTT, [*], and [D] keys, are described in the
below chart:
Operation method
(operation screen)
Description
Press the [#] key or the PTT switch
(C0 / C1 to C5 / En screen*)
Connect to the displayed node/room or
change the destination connection.
(*The PTT switch is disabled on the En screen)
Press and hold the [*] key
(Lc / Cn / C0 / C1 to C5 / En screen) Disconnect from the connected node or room.
Press and hold the [1] to [5] key
(Cn screen)
The connected node or room ID is regis-
tered to the memory of the number when it
is pressed and held (In case the memory is
already written, the registration is overwrit-
ten).
Connecting the WIRES-X feature
FTM-3207DR/DE Operating Manual
Press the [D] key
(On activating WIRES-X)
Temporarily displays the operating frequen-
cy (when calling C4FM digital signal, the
callsign of the other station is displayed).
Press the [D] key again to return to the pre-
vious screen.
8.When communication is completed, press and hold the microphone [P3] key to Exit
WIRES-X mode.
Note: About WIRES-X open node stations
A listing of the WIRES-X open node stations, with their location, operation mode, etc.
is posted on the Yaesu WIRES-X website.
https://www.yaesu.com/jp/en/wires-x/index.php
Connect and communicate with WIRES-X in analog mode
In analog mode, specify the connection destination using DTMF signals.
1. In the normal operating screen, press the [D/A(GM)] key to set the analog FM mode,
and then tune to the frequency of the node station.
Note: When DTMF function is set to “AUTO” (DTMF Icon displayed on the LCD),
change to “MANUAL” using the following steps.
Press and hold the [MHz(SETUP)] key à Rotate the DIAL knob to select “DT
AUTO 15” à Press the [MHz(SETUP)] key à Rotate the DIAL knob to select
“MANUAL” à Press and hold the [MHz(SETUP)] key
2. While holding down the PTT switch on the microphone, press the [#] key and then
enter the 5 digit ID number of the node or room to be connected, the DTMF code will
be sent to the node station.
3. Keep the transceiver in receive mode for about 10 seconds. Once connection is estab-
lished, you will be able to hear audio.
Note: The connected destination screen will not appear.
4. Face the microphone and speak.
Disconnecting from the node or room
1. While pressing the PTT switch, then enter the “#99999” (DTMF disconnect command)
keys.
Note:In analog mode, the excellent C4FM features such as clear voice, digital informa-
tion etc cannot be used, so we recommend using digital C4FM when communi-
cating with the WIRES-X Internet Linking System
FTM-3207DR/DE Operating Manual
Miscellaneous Settings
Programming the Key Assignments
Default FTM-3207DR/DE key functions have been assigned to the Microphone’s [P3]/
[P4] keys at the factory. The user may change these key function assignments, if quick
access to another function is desired.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Keyboard Beeper
A key/button beeper provides useful audible feedback whenever a key/button is pressed.
If you want to turn the beeper off (or back on again).
Note: If you want to turn the beeper off (or back on again), see Setup Menu Item “BEP
KEY 3” on 42.
Display Brightness
You can adjust the display brightness.
Note: See Setup Menu Item “LCD DMMR 22” on 43.
Time-Out-Timer (TOT)
The “Time-Out Timer” (TOT) feature is designed to force the transceiver into the “receive”
mode after a preset time period of continuous transmission (the default is 3 minutes).
Note: See Setup Menu Item “TOT 44” on 44.
Automatic Power Off (APO)
The “Automatic Power-Off” (APO) feature will turn the radio completely off after a user
defined period of PTT or key/button inactivity.
Note: See Setup Menu Item “APO 1” on 42.
Busy Channel Lock-Out (BCLO)
The BCLO feature prevents the transmitter from being activated whenever a signal strong
enough to break through the “noise” squelch is present on the frequency.
Note: See Setup Menu Item “BCLO 2” on 42.
TX Deviation Level
You can reduce the receiver bandwidth and transmit deviation when operating on closely
spaced frequencies (channel spacing of 12.5 or 15 kHz). The reduced transmitter devia-
tion will minimize adjacent channel interference to other users.
Note: See Setup Menu Item “W/N DEV 48” on 44.
MIC Gain Setting
At the factory, the microphone gain has been programmed so that it should be satisfac-
tory for the supplied MH-48A6JA Microphone. If you use an after-market microphone or
connect a TNC, you may wish to set a different Mic Gain level.
Note: See Setup Menu Item “MIC GAIN 24” on 43.
FTM-3207DR/DE Operating Manual
Displaying the Supply Voltage
Display the Power Supply voltage.
Note: See Setup Menu Item “DC VOLT 9” on 42.
Displaying the Temperature
Indicates the current temperature inside the transceiver’s case.
Note: See Setup Menu Item “TEMP 42” on 44.
Band Edge Beeper
The FTM-3207DR/DE will automatically “beep” when the receiver’s band edge is encoun-
tered during scanning (either in standard VFO scanning or during PMS operation). You
may additionally enable this feature (band edge beeper) when the frequency reaches the
band edge while selecting the VFO frequency manually, using the DIAL knob.
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
FTM-3207DR/DE Operating Manual
Setup (Menu) Mode
The FTM-3207DR/DE Setup (Menu) mode, already described in parts of many previous
chapters, is easy to activate and setup. The Menus may be used to configure many
of transceiver parameters, some of which have not been detailed previously. Use the
following procedure to activate the Setup (Menu) mode:
1. Press and hold the [MHz(SETUP)] key for
one second to enter the Setup menu.
2. Rotate the DIAL knob to select the Menu
Item to be adjusted.
3. Press the [MHz(SETUP)] key momentarily
to enable adjustment of the selected Menu
item, and then rotate the DIAL knob to per-
form the actual adjustment.
4. After completing the selection and adjust-
ment, press and hold the [MHz(SETUP)] key
for one second to exit the Setup menu and
resume normal operation.
VOL
DIAL
SQL
TXPO
D W
M W
SETUP
REV
D/A
V / M
MHz
Note: For details, refer to the Advanced Manual (download from the Yaesu website).
Menu Item
Function
Available Values
Default
1: APO
Enables/Disables the Automatic Power
Off feature.
0.5H to 12H (0.5H step)/
OFF
OFF
2: BCLO
Enables/Disables the Busy Channel
Lock-Out feature.
ON/OFF
OFF
3: BEP KEY
Enables/Disables the key beeper.
KEY+SCAN/KEY/OFF
KEY+SCAN
4: BEP EDGE
Enables/Disable the Band-edge beeper
while scanning.
ON/OFF
OFF
5: BEP LVL
Sets the beep level
High/Low
High
6: BEP STBY
Enables/Disable the Standby beep
ON/OFF
ON
7: BELL
Selects the CTCSS/DCS/EPCS Bell
Ringer repetitions.
1 to 20/CONTINUE/OFF
OFF
8: CLK TYPE
Shifting of the CPU clock frequency.
A/B
A
9: DC VOLT
Indicates the DC Supply Voltage.
---
---
10: DCS CODE
Setting of the DCS code.
104
standard
DCS
codes
023
11: DCS INV
Select a combination of DCS inversion
codes in terms of communication direc-
tion.
N O R M A L / I N V E R T /
BOTH
NORMAL
12: DIG AMS
Sets the transmission mode
TXMANUAL/TX FMFIX/
TX DNFIX/AUTO
TXMANUAL
13: DI POPUP
Sets the information pop-up time
2/4/6/8/10/20/30/60/
CONTINUE/OFF
10 SEC
14: DPID LST
DP-ID list (Display/Register/Clear)
(Registered DP-ID)
---
15: DT AUTO
Enables/Disables the DTMF Autodialer
feature.
MANUAL/AUTO
MANUAL
Setup (Menu) Mode
FTM-3207DR/DE Operating Manual
Menu Item
Function
Available Values
Default
16: DT DELAY
Setting of the DTMF Autodialer TX Delay
Time.
50/250/450/750/1000
450 MS
17: DT SET
Loading of the DTMF Autodialer Memo-
ries.
---
---
18: DT SPEED
Setting of the DTMF Autodialer Sending
Speed.
50/100
50 MS
19: DW RVRT
Enables/Disables the “Priority Channel
Revert” feature.
ON/OFF
OFF
20: GM RINGR
Enables/Disables the alert sound when
detecting stations within communication
range
IN RANGE/ALWAYS/OFF
IN RANGE
21: GM INTVL
Selects the automatic sending interval.
NORMAL/LONG
NORMAL
22: LCD DMMR
Setting of the front panel display illumi-
nation level.
LEVEL 1/2/3/4
LEVEL 4
23: LOCK
Selects the Control Locking Lockout
combination.
K E Y + D I A L / P T T /
KEY+PTT/DIAL+PTT/
ALL/KEY/DIAL
KEY+DIAL
24: MIC GAIN
Adjust the microphone gain level.
LEVEL 1 to 9
LEVEL 5
25: MEM NAME
Programming an Alpha/Numeric label for
a Memory Channel.
---
---
26: MW MODE
Selects the method of selecting of chan-
nels for Memory Storage.
NEXT CH/LOWER CH
NEXT CH
27: OPEN MSG
Selects the Opening Message that ap-
pears when the radio is powered ON.
OFF/DC/MESSAGE
MESSAGE
28: PAG CD-R
Setting the Receiver Pager Code for
the Enhanced CTCSS Paging & Code
Squelch function.
---
05 47
29: PAG CD-T
Setting the Transmitting Pager Code for
the Enhanced CTCSS Paging & Code
Squelch function.
---
05 47
30: PRG P3
Programming the function assigned to
Microphone [P3] key.
SQL OFF
HOME
CD SRCH
SCAN
T CALL
TX POWER
DIG/ANA
GM
WIRES
Setup Menu Item #1 to
50
WIRES
31: PRG P4
Programming the function assigned to
Microphone [P4] key.
ø
32: RADIO ID
Displays the transceiver IDs
øøøøø (uneditable)
---
33: RF SQL
Adjusts the RF Squelch threshold level.
OFF/S1 to S8
OFF
34: RPT ARS
Activates/Deactivates the Automatic Re-
peater Shift feature.
ON/OFF
ON
35: RPT FREQ
Sets the magnitude of the Repeater Shift.
0.00 - 150.00 (MHz)
ø
36: RPT SFT
Sets the Repeater Shift direction.
-RPT/+RPT/SIMPLEX
SIMPLEX
37: SCAN RSM
Selects the Scan Resume mode.
BUSY/HOLD/2-10 (SEC)
5.0 SEC
Setup (Menu) Mode
FTM-3207DR/DE Operating Manual
Menu Item
Function
Available Values
Default
38: SCAN SKP
Selects the Memory Scan mode.
OFF/SKIP/SELECT
OFF
39: SQL EXP
Enables/Disables the split CTCSS/DCS
coding.
ON/OFF
OFF
40: SQL TYPE
Selects the Tone Encoder and/or Decod-
er mode.
TONE/TSQL/DCS/
RV TONE/PAGER/OFF
OFF
41: STEP
Sets the frequency synthesizer steps.
AUTO/5/6.25/10/12.5/15
/20/25/50/100 (kHz)
AUTO
42: TEMP
Indicates the current temperature inside
the transceiver.
---
---
43: TONE FRQ
Setting of the CTCSS Tone Frequency.
67.0 to 254.1 (Hz)
100.0 HZ
44: TOT
Sets the Time-Out Timer.
0.5 to 10.0 (MIN)/OFF
3.0 MIN
45: TS MUTE
Enables/Disables the receiver audio out-
put while the Tone Search or DCS Search
Scanner is activated.
ON/OFF
ON
46: TS SPEED
Selects the Tone Search or DCS Search
Scanner speed.
FAST/SLOW
FAST
47: VER DISP
Displays the transceiver software version
CPU x.xx
DSP x.xx
---
48: W/N DEV
Reduction of the Microphone Gain/Devia-
tion and receiver bandwidth.
WIDE/NARROW
WIDE
49: W-DGID
Setting of the WIRES-X DGID
AUTO/DGID01-99
AUTO
50: MY CALL
Sets your station call sign
- - - - - - - - - -
---
ø: Depends on the transceiver version.
FTM-3207DR/DE Operating Manual
Maintenance
Care and maintenance
Turn the power OFF before wiping away any dust and stains on the transceiver with a dry
soft cloth. For stubborn stains, slightly moisten a soft cloth and wring it out before using it
to wipe away the stains.
Caution: Never use washing detergents and organic solvents (thinner, benzene, etc.).
Doing so may result in paint flaking or damage to the transceiver finish.
Replacing the fuse
When the fuse of the DC power supply cable blows and the transceiver becomes
inoperable, correct the cause of the problem, and then replace the fuse with a new one of
the correct rating (USA version: 25 Amp, EXP/European version: 20 Amp).
Caution: When replacing the fuse, be sure to disconnect the power supply cable from
the transceiver and from the external DC power supply.
Replacing the fuse of the DC power supply cable
1. Prepare a new fuse.
Use a fuse with a rating of 25 A or 20 A.
Caution: Never attempt to use a fuse that is
not of the specified rating.
USA version: 25 Amp
EXP/European version: 20 Amp
2. Open the fuse holder as shown in the dia-
gram on the right.
3. Remove the blown fuse.
4. Attach the new fuse.
5. Close the fuse holder.
FTM-3207DR/DE Operating Manual
Specifications
General
Frequency Range:
Tx 430 - 450 MHz(USA version)
430 - 440 MHz(European version)
420 - 470 MHz(Asian version)
Rx 420 - 470 MHz
Channel Step:
5/6.25/10/12.5/15/20/25/50/100 kHz
Standard Repeater Shift:
±5 / 7.6 MHz
Frequency Stability:
±2.5 ppm [-4 °F to +140 °F (-20 °C to +60 °C)]
Modes of Emission:
F2D/F3E/F7W
Antenna Impedance:
50 Ohms, unbalanced
Supply voltage:
13.8 V DC ±15%, negative ground
Current Consumption (typical): Rx: less than 0.7 A, less than 0.5 A (squelched)
Tx: 10 A (55 W) /6 A (25 W) /3 A (5 W)
Operating Temperature Range: -4° F to +140° F (-20° C to +60° C)
Case Size (WxHxD):
6.1” x 1.7” x 6.1” (154 x 43 x 155 mm) (w/o knobs)
Weight (Approx.):
2.86 lbs (1.3 kg)
Transmitter
Output Power:
55/25/5 W
Modulation Type:
F2D/F3E: Variable Reactance
F7W: 4FSK (C4FM)
Maximum Deviation:
±5 kHz (Wide)
±2.5 kHz (Narrow)
Spurious Radiation:
Better than -60 dB
Better than -61.1 dB (European version, 55 W)
Microphone Impedance:
2k Ohms
Receiver
Circuit Type:
Double Conversion Superheterodyne
Ifs:
1st 47.25 MHz, 2nd 450 kHz
Sensitivity (for 12dB SINAD):
0.20 μV (Ham band, wide)
0.22 μV (Ham band, narrow)
Sensitivity (for Digital):
0.22 μV (BER 1%)
Selectivity (–6/–60dB):
12 kHz/28 kHz
Maximum AF Output:
3 W into 4 Ohms with 10% THD
Specifications are subject to change without notice, and are guaranteed within the 430
MHz amateur bands only. Frequency ranges will vary according to transceiver version;
check with your dealer.
FTM-3207DR/DE Operating Manual
An amateur band radio doesn’t require Certification/Verification for the transmitter under Part 97
z
z Changes or modifications to this device that are not expressly approved by YAESU MUSEN could
void the user’s authorization to operate this device.
z
z This device complies with part 15 of the FCC Rules. Operation is subject to the following two con-
ditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference including received, interference that may cause undesired operation.
z
z The scanning receiver in this equipment is incapable of tuning, or readily being altered, by the User
to operate within the frequency bands allocated to the Domestic public Cellular Telecommunications
Service in Part 22.
z
z The YAESU MUSEN is not responsible for any changes or modifications not expressly approved by
the party responsible for compliance. Such modifications could void the user’s authority to operate
the equipment.
This device complies with ISED’s applicable license-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit
pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
DECLARATION BY MANUFACTURER
The Scanner receiver is not a digital scanner and is incapable of being converted or modified to a
digital scanner receiver by any user.
WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR RADIOTELEPHONE
SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW.
CAN ICES-3 (B) / NMB-3 (B)
This equipment has been tested and found to comply with the limits for a Class B digital device, pur-
suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy; and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be deter-
mined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
r Reorient or relocate the receiving antenna.
r Increase the separation between the equipment and receiver.
r Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
r Consult the dealer or an experienced radio/TV technician for help.
FTM-3207DR/DE Operating Manual
Declaration of Conformity
Type of Equipment:
UHF DIGITAL/ANALOG TRANSCEIVER
Brand Name:
YAESU
Model Number:
FTM-3207DR
Manufacturer:
YAESU MUSEN CO., LTD.
Address of Manufacturer:
Tennozu Parkside Building, 2-5-8 Higashi-Shinagawa,
Shinagawa-ku,Tokyo 140-0002 Japan
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions; (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
The technical documentation as required by the Conformity Assessment procedures is
kept at the following address:
Company: Yaesu U.S.A.
Address:
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
Telephone: (714) 827-7600
EU Declaration of Conformity
We, Yaesu Musen Co. Ltd of Tokyo, Japan, hereby declare that this radio equipment FTM-3207DE is
in full compliance with EU Radio Equipment Directive 2014/53/EU. The full text of the Declaration of
Conformity for this product is available to view at http://www.yaesu.com/jp/red
ATTENTION – Conditions of usage
This transceiver works on frequencies that are
regulated and not permitted to be used without
authorisation in the EU countries shown in this table.
Users of this equipment should check with their
local spectrum management authority for licensing
conditions applicable for this equipment.
AT
BE
BG
CY
CZ
DE
DK
ES
EE
FI
FR
UK
GR
HR
HU
IE
IT
LT
LU
LV
MT
NL
PL
PT
RO
SK
SI
SE
CH
IS
LI
NO
–
–
–
–
Disposal of Electronic and Electrical Equipment
Products with the symbol (crossed-out wheeled bin) cannot be disposed as
household waste.
Electronic and Electrical Equipment should be recycled at a facility capable of
handling these items and their waste by-products.
Please contact a local equipment supplier representative or service center for
information about the waste collection system in your country.
Printed in Japan
Copyright 2018
YAESU MUSEN CO., LTD.
All rights reserved.
No portion of this manual may be
reproduced without the permission of
YAESU MUSEN CO., LTD.
YAESU MUSEN CO., LTD.
Tennozu Parkside Building
2-5-8 Higashi-Shinagawa, Shinagawa-ku, Tokyo
140-0002 Japan
YAESU USA
6125 Phyllis Drive, Cypress, CA 90630, U.S.A.
YAESU UK
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
1801I-CO-1