INDEX (CLICK TO NAVIGATE TO PAGE)

PAGE 1 RECEIVER PART IDENTIFICATION 2 ITA PART IDENTIFICATION 3 RECEIVER/ITA ENGAGEMENT & DISENGAGEMENT 4 RECEIVER MOUNTING 5 ITA COVER REMOVAL 6 ITA COVER INSTALLATION 8 CABLE CLAMP REMOVAL & INSTALLATION 9 CONTACT REMOVAL 10 RECEIVER STRAIN RELIEF ASSEMBLY 11 RECEIVER PROTECTIVE COVER INSTALLATION 12 ITA PROTECTIVE COVER INSTALLATION 13 KEYING PIN KIT, RECEIVER & ITA ASSEMBLY 14 PCB ASSEMBLY W/ TWO HEADERS 15 PCB LAYOUT W/ HEADER 16 STANDARD PCB LAYOUT 17 HYBRID PCB LAYOUT W/ HEADER 18 HYBRID STANDARD PCB LAYOUT 19 TROUBLESHOOTING i2 MICRO iCON USER MANUAL 07/23/21 Please note that any printed or downloaded User Manuals may not reflect the most current revisions. The information contained in this material is subject to change. The most current information available will be on vpc.com.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 1 RECEIVER PART IDENTIFICATION PART # 310 130 XXX (Figure A) notes distinguishing features of the i2 Micro iCon receiver for identification of the top and bottom of the receiver. Features to look for are the numeric keying receptacle on the top side and the alpha keying receptacle on the bottom. The front and rear of the receiver are shown in (Figure B). The front has a polarizing feature which prevents the i2 Micro iCon ITA and receiver from being engaged upside down. The front of the receiver can be identified as the side with the latching feature. NOTE: The i2 Micro iCon is the only product in VPC’s iSeries product line that features a receiver that acts as the module. All other products feature modules that are independent from the receiver or ITA. The front side mates with the ITA. Wires exit the receiver from the rear side. Figure A. i2 Micro iCon receiver front view. Figure B. i2 Micro iCon receiver side view. Alpha Keying Receptacle Numeric Keying Receptacle Top Bottom Front Mating Side Rear Wiring Side Polarizing Feature Latching Feature Pin 1A Indicator Figure C. Pin location layout.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 2 ITA PART IDENTIFICATION PART # 410 130 XXX (Figure A) points out distinguishing features of the i2 Micro iCon ITA so that the top and bottom can be identified. Features to look for are the numeric keying receptacle on the top side and the alpha keying receptacle on the bottom. The front and rear of the ITA are easily distinguished as shown in (Figure B). The front has a protruding guide plate with locking tabs and the rear has the knob. The front side mates with the i2 Micro iCon receiver. The front has a polarizing feature which prevents the ITA and receiver from being engaged upside down. Wires exit the ITA through the 30° cable exit. Figure A. i2 Micro iCon ITA front view. Figure B. i2 Micro iCon ITA side view. Alpha Keying Receptacle Numeric Keying Receptacle Locking Tabs Top Bottom Front Mating Side Rear Wiring Side Polarizing Feature 30° Cable Exit Figure C. Pin location layout.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 3 RECEIVER/ITA ENGAGEMENT AND DISENGAGEMENT RECEIVER • PART # 310 130 XXX ITA • PART # 410 130 XXX ENGAGEMENT INSTRUCTIONS 1. Turn the engagement knob counter-clockwise to the open/ disengaged position (Figure A). 2. Align the i2 Micro iCon ITA with the receiver and gently push the ITA onto the receiver. There will be about a 0.25″ [6.35 mm] gap. NOTE: The ITA is polarized and will not align if it is upside down. NOTE: The ITA can be left in this position without engaging the system. 3. Rotate the engagement knob clockwise to engage (Figure B). NOTE: For optimum performance and system longevity, distribute the contact load evenly. 3/32 3/32 DISENGAGEMENT INSTRUCTIONS 1. Turn the engagement knob counter-clockwise to the open/ disengaged position (Figure A). 2. Remove the ITA by gently pulling backwards. NOTE: For unbalanced loads, add force to the lower pin load during disengagement to prevent binding. Figure A. Disengaged ITA and receiver. Figure B. Engaged ITA and receiver.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 4 RECEIVER MOUNTING PART # 310 130 XXX TOOLS REQUIRED Phillips Head Screwdriver MOUNTING INSTRUCTIONS 1. Prepare the mounting surface using the dimensions provided in (Figure A). 2. Attach the i2 Micro iCon receiver to the panel with the provided 2-56 Phillips head screws and nuts (Figure B). Torque screws to 2 in-lbs [0.23 Nm]. NOTE: If the mounting surface is thicker than 0.125″ [3.18 mm], longer screws may be needed. NOTE: If the mounting surface has threaded holes, the nuts will not be needed. NOTE: M2 hardware can be used in place of the provided 2-56 hardware. NOTE: The dimensions shown reflect use of a laser cutting or punch press process. If using conventional machining processes the 3.49″ [88.65] dimension will be 3.69″ [93.73] and a .09″ [2.29] radius needs to be added to the corners. Figure A. Recommended panel cutout. Figure B. If metric hardware is preferred, the supplied 2-56 hardware can be replaced with M2 hardware. .74 18.8 3.49 88.6 .23 5.7 3.940 100.07 .100 THRU, TYP. 4 PLCS FOR MOUNTING PLATES THICKER THAN .09" .086-56UNC-2B THRU, TYP. 4 PLCS. FOR MOUNTING PLATES .09" THICK OR LESS .36 TYP. 9.1 .19 TYP. 4.8 .050 TYP. 1.27 R.09 TYP. 2.3 4 .640 TYP. 16.26 TOLERANCES ARE: .XX = [.25].01 .XXX = [.13] .005 UNLESS OTHERWISE SPECIFIED 5 TYP. *SPACING IS APPLICATION SPECIFIC, .80" MINIMUM, 1.00" RECOMMENDED TABLE 1 4 SEE TABLE 1 FOR MINIMUM DISTANCE OF SUBSEQUENT SIDE BY SIDE CUTOUTS. 5 PART NUMBER DESCRIPTION RECEIVER CUTOUT SPACING 410130101 ITA, i2 Micro iCon, 168 Position 1.00 [25.40] 410130104 ITA, i2 Micro iCon, 120/12 Position Hybrid 1.00 [25.40] 410130106 ITA, i2 Micro iCon, 168 Position with Oversized Backshell 2.19[55.63] 410130115 ITA, i2 Micro iCon, 120/12 Position Hybrid with Oversized Backshell 2.19[55.63] 5

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 5 ITA COVER REMOVAL PART # 410 130 XXX TOOLS REQUIRED Phillips Head Screwdriver Flat Head Screwdriver REMOVAL INSTRUCTIONS 1. Disengage the i2 Micro iCon ITA from the receiver. 2. If the ITA is wired, remove the cable clamp/strain relief bar (see page 8 of this user manual). 3. Using a flat head screwdriver, remove the engagement knob screw and engagement knob (Figure A). 4. Using a Phillips head screwdriver, loosen the four screws (captive) that secure the cover to the ITA/module (Figure B). 5. Slide the cover down (Figure C) so that the insert clears the bottom of the ITA/module. 6. Remove the insert from the cover by sliding it toward the mating face of the ITA/module (Figure C). 7. Remove the cover from the ITA/module (Figure D). Figure B. Loosen cover mounting screws. Figure A. Remove engagement knob. Figure D. Remove cover. Figure C. Remove insert from cover.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 6 ITA COVER INSTALLATION PART # 410 130 XXX TOOLS REQUIRED Phillips Head Screwdriver Flat Head Screwdriver INSTALLATION INSTRUCTIONS 1. With the needed wires/contacts installed in the i2 Micro iCon ITA/module, distribute the wires evenly around the drive shaft (Figure A). 2. Place the cable bundle in the u-shaped cable clamp portion of the cover and position the cover against the wiring side of the ITA/module (Figure B). 3. With the cover against the wiring side of the ITA/module, slide the cover down so that the slot for the cover insert clears the bottom of the ITA/module (Detail A in Figure C). 4. Slide the insert into the cover in the orientation shown (Figure C). Continued on next page... Figure B. Position cover. Figure A. Distribute wires evenly around drive shaft. Figure C. Slide cover down and install insert.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 7 Figure E. Reinstall engagement knob. Figure D. Secure cover to ITA/module. ITA COVER INSTALLATION PART # 410 130 XXX INSTALLATION INSTRUCTIONS (CONT’D) 5. Secure the cover to the i2 Micro iCon ITA/module by tightening the four Phillips head screws (Figure D) in a criss cross pattern using a Phillips head screwdriver. Torque to 2 in-lbs [0.23 Nm]. 6. Install the engagement knob and tighten the engagement knob screw using a flat head screwdriver (Figure E). Torque to 4 in-lbs [0.46 Nm]. 7. Secure the cable bundle using the strain relief bar. (See page 8 of this user manual for more information.)

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 8 CABLE CLAMP REMOVAL AND INSTALLATION PART # 410 130 XXX TOOLS REQUIRED Phillips Head Screwdriver REMOVAL INSTRUCTIONS 1. Remove the two 4-40 x 1.5″screws and strain relief bar from the i2 Micro iCon ITA cover (Figure A). INSTALLATION INSTRUCTIONS 1. Install the two 4-40 x 1.5″ screws and strain relief bar from the ITA cover (Figure A). 2. Slowly alternate tightening the 4-40 x 1.5″ screws until the strain relief bar is snugly against the cable bundle (Figure B). NOTE: Reverse the orientation of the strain relief bar to accommodate smaller cable bundles. Figure A. Removal/Installation of the strain relief bar. FORMULA TO CALCULATE THE MAXIMUM NUMBER OF WIRES IN A CABLE BUNDLE B = 1.2 √(N1d1 2+ N2d2 2 . . . +Nndn 2) WIRE TYPE Ø [in] # WIRES BUNDLE Ø [in] 26AWG 16878/4 0.043 221 0.77 24AWG 16878/4 0.048 177 0.77 22AWG 16878/4 0.054 141 0.77 M27500-26ml2t08 0.114 31 0.76 M27500-24ml2t08 0.126 26 0.77 M27500-22ml2t08 0.140 21 0.77 M27500-22ml1t08 0.087 54 0.77 22AWG 16878/4 T/P 0.108 35 0.77 24AWG 16878/4 T/P 0.096 44 0.76 NOTE: Acceptable bundle dimension must be reduced when using sleeving and shrink tubing. Figure B. Cable clamp exit area. Flatten larger wire bundles to fit oblong cable exit B = Wire Bundle Diameter N1 = Quantity of first wire type N2 = Quantity of second wire type Nn = Quantity of nth wire type d1 = Outside Diameter of first wire type d2 = Outside Diameter of second wire type dn = Outside Diameter of nth wire type

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 9 TOOLS REQUIRED Phillips Head Screwdriver Flat Blade Screwdriver RECEIVER INSTRUCTIONS 1. Remove the strain relief or keying pins (refer to page 11 of this user manual) if needed. 2. Using the Phillips head screwdriver, remove the four panel mounting screws from the top and bottom of the i2 Micro iCon receiver (Figure A). 3. Using the flat head screwdriver, remove the two flat head assembly screws from the back of the receiver (Figure A). 4. Insert the flat blade screwdriver into the slot on the top of the receiver and pry the end of the receiver using a twisting motion until visible separation is indicated. Repeat on the opposite end of the receiver. 5. Grasp the receiver halves and apply force in opposite directions, rocking the ends of the receiver while slightly pulling the front of the receiver away from the mating back section. Be sure to open both sides of the receiver simultaneously or contacts could be damaged. 6. Extract the signal contact per the QuadraPaddle User Manual. Reference contact part # 610 138 200 for receiver part # 310 130 101 or contact part # 610 138 216 for receiver part # 310 130 102. For Hybrid Receivers (Part # 310 130 104 or 310 130 105): 7. Extract the power contact per the Micro Power User Manual. Reference contact part # 610 142 101. 8. Extract the Coax contact per the Micro Coax User Manual. Reference contact part # 610 140 XXX. ITA INSTRUCTIONS 1. Refer to page 5 for i2 Micro iCon ITA cover removal instructions. 2. Extract the signal contacts per the QuadraPaddle User Manual. Reference contact part # 610 138 109 or 610 138 112. For Hybrid ITA (Part # 410 130 104): 3. For extraction, use the Micro Power/Micro Coax extraction tool part # 910 112 127. Extract the power contact per the Micro Power User Manual. Reference contact part # 610 143 101. 4. For extraction, use the Micro Power/Micro Coax extraction tool part # 910 112 127. Extract the coax contact per the Micro Coax User Manual. Reference contact part # 610 141 XXX. Figure A. i2 Micro iCon Receiver separation. CONTACT REMOVAL PART # 310 130 XXX, 410 130 XXX Panel Mounting Screws Assembly Screws Figure B. i2 Micro iCon Hybrid receiver separation. Panel Mounting Screws Assembly Screws

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 10 Figure A. i2 Micro iCon receiver strain relief. TOOLS REQUIRED Phillips Head Screwdriver ASSEMBLY INSTRUCTIONS 1. Using the Phillips head screwdriver, fasten the strain relief to the back (wiring) side of the i2 Micro iCon receiver with the 2-56 screws and nuts provided (Figure A). Place the nuts in the keying positions from the front side of the receiver. NOTE: If using the keying features, replace the 2-56 nuts with the keying pins (Figure B). 2. Torque screws to 2 in-lbs [0.23 Nm]. NOTE: Four wiring ties are included with the strain relief for restraining wires. RECEIVER STRAIN RELIEF ASSEMBLY PART # 310 113 559 Figure B. i2 Micro iCon receiver strain relief with keying pins.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 11 RECEIVER PROTECTIVE COVER INSTALLATION PART # 310 113 667 INSTALLATION INSTRUCTIONS 1. To attach the i2 Micro iCon receiver protective cover to the receiver, you may discard the mounting screw that is supplied with the cover. 2. Use the eyelet coupling on the cover’s chain lanyard to attach the cover to the receiver. Place the 2-56 bottom right mounting screw used to mount the receiver to the panel, through the eyelet coupling. 3. Secure the mounting screw and nuts to the receiver. The eyelet should now be securely mounted between the screw head and receiver. (Figure B). Figure A. Figure B.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 12 ITA PROTECTIVE COVER INSTALLATION PART # 410 113 208 INSTALLATION INSTRUCTIONS 1. To attach the i2 Micro iCon ITA protective cover to the ITA you may discard the mounting screw that is supplied with the cover. 2. Use the eyelet coupling on the cover’s chain lanyard to attach the cover to the ITA. Place one of the 4-40 x 1.5” screws through the eyelet and insert into the ITA. 3. Follow the instructions for “Cable Clamp Installation” on page 8 of this User Manual to properly tighten and install the cable clamp. 4. When properly installed the eyelet should be securely mounted between the screw head and ITA housing.(Figure A). Figure A.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 13 KEYING PIN KIT, RECEIVER AND ITA ASSEMBLY PART # 310 113 461 TOOLS REQUIRED Phillips Head Screwdriver ASSEMBLY INSTRUCTIONS 1. Determine the keying pin’s desired orientation (Figure A). 2. Using a Phillips head screwdriver, secure a keying pin in the i2 Micro iCon receiver with the 2-56 screws provided (Figure B). Torque screws to 2 in-lbs [0.23 Nm]. NOTE: If the strain relief plate, Part # 310 113 559 is being used, replace the screws used to secure the keying pins with the screws included with the strain relief plate. 3. Remove the i2 Micro iCon ITA cover (see page 5 of this user manual). 4. Using a Phillips head screwdriver, secure a keying pin in the ITA with the 2-56 screws provided (Figure C). Torque screws to 2 in-lbs [0.23 Nm]. 5. Replace the ITA cover (see page 5 of this user manual). Figure A. i2 Micro iCon receiver and ITA mating faces. In order to mate the connector, the keying pin must be in the same numeric position in both the receiver and ITA. Figure B. i2 Micro iCon receiver with keying pins. Figure C. i2 Micro iCon ITA with keying pins. The iSeries keying kit includes two pins and screws which provide six different keying options. The i2 Micro iCon is designed to accept two kits which increase the keying options to 36.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 14 PCB ASSEMBLY 84 PIN HEADER, PART # 510 109 204 • 60 PIN HEADER, PART # 510 109 206 MOUNTING BRACKET, PART # 310 113 562 TOOLS REQUIRED Phillips Head Screwdriver ASSEMBLY INSTRUCTIONS 1. Assemble two headers to the PCB. See next page for recommended PCB layout. NOTE: To ensure a secure connection without damaging the PCB, the board must be properly supported between the mounting holes to distribute pressure evenly. Otherwise, the insertion force may be high enough to damage or break the board. Reference VPC part # 910 121 199 if a tool is needed. 2. Using the Phillips head screwdriver, secure the headers and mounting bracket (Part # 310 113 562) to the PCB using the supplied 2 mm screws (Figure A). 3. Secure the receiver to the mounting panel (Figure B) following the recommended panel cutout (see page 4 of this user manual). 4. Using the Phillips head screwdriver, press the PCB and headers onto the receiver and secure the mounting bracket to the receiver using the supplied captive 2-56 screw (Figure C). Figure A. Secure headers and mounting bracket to PCB. Figure B. Secure receiver to mounting panel. Figure C. Secure mounting bracket to receiver.

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 15 PCB LAYOUT HEADER, 84 POSITION RIGHT ANGLE WITH COMPLIANT PIN • PART # 510 109 204 (Figure A.) PCB layout. Connector mounts this side. Board thickness = [1.57] .062 or [2.29] .090 .072-.001 +.002 TYP. UNPLATED THRU HOLE MOUNTING BOSS 2 PLCS. .100 TYP. THRU HOLE MOUNTING SCREW UNPLATED 2 PLCS. .123±.002 3.12±0.05 .148 3.76 1.669 42.39 1.735 44.07 1.845 46.86 .148 3.76 .217 5.51 R.050 TYP. 1.300 13 EQ. [email protected][2.54] 33.02 .500 5 EQ. SPCS. @ .100 [2.54] 12.70 .700 17.78 .062±.002 PAD BOTH SIDES .553±.002 14.05±0.05 .528 13.41 HEADER PERIMETER OUTLINE B C PIN A1 A BOARD THICKNESS = [1.57] .062 OR [2.29] .090 .XX = [.25].01 .XXX = [.13].005 CONNECTOR MOUNTS THIS SIDE TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED RECOMMENDED PCB LAYOUT 1 PIN F1 .043 .038 PLATED THRU HOLE TYP. 84 PLCS. (HASL) TIN/LEAD PLATED 1.09 0.97 .006 A B C COMPLIANT PIN (Figure C.) Compliant header pin. (Figure B.) Two header layout for 310 130 101 receiver. 1.950 49.53

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 16 STANDARD PCB LAYOUT i2 RECEIVER • PART # 310 130 101 (Figure A) PCB layout for i2 receiver, Part # 310 130 101. Through hole and pad diameters are for VPC QuadraPaddle male Adapter Contact, Part # 610 138 117. The size of these holes may be different if a header from a different manufacturer is used. Connector mounts this side. .640 16.26 3.940 100.08 .345 8.76 1.300 13 EQ. SPCS. @ [2.54] .100 33.02 1.950 49.53 .070 1.78 .500 5 EQ. SPCS. @ [2.54] .100 12.70 .100 THROUGH 2.54 .037±.003 PLATED THROUGH HOLE TYP. 168 PLCS. 0.94±0.08 .060 PAD TYP. 168 PLCS. PIN A1 1 .0021 LOCATION TOLERANCES APPLIES TO PLATED THROUGH HOLES .XX = [.25].01 .XXX = [.13].005 CONNECTOR MOUNTS THIS SIDE TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED RECOMMENDED PCB LAYOUT 1 1 PIN F1 (Figure B) i2 receiver, Part # 310 130 101, loaded with twin female contacts, Part # 610 138 200. Twin male headers are used to connect the female contacts to the PCB plated through holes. (Figure D) A PCB can be mounted directly to the back of an i2 receiver as shown above. Four 2-56 or M2 screws are required to mount the receiver. Spacers may be needed to prevent unwanted stress on the PCB. 0.22” [5.6 mm] / 0.45” [11.4 mm] HEADER CARRIER HEIGHT (Figure C). Twin male header. NOTE: (Figure C) details 0.22” [5.59 mm]/0.45” [11.43 mm] min/ max engagement. NOTE: Minimum spacer height = 0.24” + header carrier height - panel thickness (if used). Any additional height beyond this minimum must be added to the header post limits shown in (Figure C). NOTE: Several manufacturers offer the twin male header: Samtec, TE, MultiComp, Molex. The specific part number required is dependant on the distance the i2 will be located from the PCB, the thickness of the PCB, and the plating type required. SPACER (SEE NOTE) PCB HEADER, .100" SPACING TWIN MALE SOLDERED TO PCB CREATES A SEPERABLE INTERFACE i2 RECEIVER

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 17 HYBRID PCB LAYOUT HEADER, 60 POSITION RIGHT ANGLE WITH COMPLIANT PIN • PART # 510 109 206 1.57±0.05 .062±.002 PAD BOTH SIDES 22.86 .900 9 EQ. [email protected][2.54] 3.76 .148 12.70 .500 5 EQ. SPCS.@ .100[2.54] A B BOARD THICKNESS = [1.57] .062 OR [2.29] .090 .XX = [.25].01 .XXX = [.13].005 CONNECTOR MOUNTS THIS SIDE TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED RECOMMENDED PCB LAYOUT PIN A1 1 PIN F1 1.09 0.97 .043 .038 PLATED THROUGH HOLE TYP. 60 PLCS. (HASL) TIN/LEAD PLATED .006 A B (Figure A) PCB layout. Connector mounts this side. Board thickness = [1.57] .062 or [2.29] .090 COMPLIANT PIN (Figure C) Compliant header pin. (Figure B) Two header layout for 310 130 104 receiver. .100 TYP. THROUGH HOLE MOUNTING SCREW UNPLATED 7.14 .281 9.65 .380 37.72 1.485 4.09 .161 59.69 2.350

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 18 HYBRID STANDARD PCB LAYOUT i2 HYBRID RECEIVER • PART # 310 130 104 16.26 .640 100.08 3.940 1.78 .070 12.70 .500 5 EQ. SPCS. @[2.54].100 8.76 .345 22.86 .900 9 EQ. SPCS. @ [2.54].100 59.69 2.350 33.53 1.32 33.02 1.30 15.24 .60 1.52 .060 PAD TYP. 120 PLCS. CUTOUT FOR ACCESS TO MICRO PIN POSITIONS [2.54] .100 THROUGH TYP. 4 PLCS. [0.94 0.08] .037 .003 PLATED THROUGH HOLE TYP. 120 PLCS. PIN A1 1 .0021 LOCATION TOLERANCES APPLIES TO PLATED THROUGH HOLES .XX = [.25].01 .XXX = [.13].005 CONNECTOR MOUNTS THIS SIDE TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED RECOMMENDED PCB LAYOUT 1 1 PIN F1 (Figure B) PCB layout for i2 hybrid receiver, Part # 310 130 104. Through hole and pad diameters are for VPC QuadraPaddle male Adapter Contact, Part # 610 138 117. The size of these holes may be different if a header from a different manufacturer is used. Connector mounts this side. (Figure C) PCB layout for i2 hybrid receiver, Part # 310 130 104. Through hole and pad diameters are for VPC QuadraPaddle Adapter Contact, Part # 610 138 117 and for Micro Coax and/or Micro Power contacts. The size of these holes may be different if a header from a different manufacturer is used. Connector mounts this side. [100.08] 3.940 .070 [1.78] [1.52] Ø.060 TYP. 120 PLCS. PAD @[ 2.54 ] .100 5 EQ. SPCS. .500 [12.70] .640 [16.26] .185 [2.79] TYP. 4 PLCS. THROUGH Ø.110 [22.86] .900 9 EQ. SPCS. @[ 2.54 ] .100 @ .185 BSC. [4.70] [59.69] 2.350 [3.81] .150 2.000 [50.80] 2 EQ. SPCS. PLATED THROUGH HOLE ±.003 Ø.037 ±0.08 ] [ 0.94 .370 [9.40] TYP. 120 PLCS. Ø.166 THROUGH TYP. 12 PLCS. [27.05] 1.065 [8.76] .345 PIN A1 1 .0021 LOCATION TOLERANCES APPLIES TO PLATED THROUGH HOLES .XX = [.25].01 .XXX = [.13].005 CONNECTOR MOUNTS THIS SIDE TOLERANCES ARE: UNLESS OTHERWISE SPECIFIED RECOMMENDED PCB LAYOUT 1 1 PIN F1

i2 MICRO iCON USER MANUAL

VPC 07/23/21 For more information visit vpc.com RETURN TO INDEX 19 Forceful engagement when attempting to mate the receiver and the ITA will result in serious damage to multiple parts of the system (modules, receiver, ITA and contacts) ITA frame is not lined up when engaging with the receiver. This may indicate that the ITA was dropped and is out of alignment or that a module is not mating with its intended module. • Remove and inspect the ITA for alignment. • Check for foreign objects/tools. • Inspect the matching of modules - signal ITA module mating with signal receiver module, etc. • The keying pin locations mate. • Make sure engagement knob is installed incorrectly. TROUBLESHOOTING