Volt VPL-1012-BBZ Installation Instructions

Specifications

Brand: Volt
Category: Landscape Lighting
Model: VPL-1012-BBZ (Installation Instructions)
File Type: PDF
File Size: —
Pages: 5

Read Online

Read the Volt VPL-1012-BBZ Installation Instructions online using the built-in PDF viewer.

Text of the manual

VOLT® Low Voltage Landscape Lighting

VOLT® Brass Regal Path & Area Light VPL-1012-BBZ INSTALLATION INSTRUCTIONS Specifications and product details subject to change without notice. © Copyright 2019, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved. [email protected] • 813.978.3700 Help Hotline: 1-813-978-3700 • Mon-Fri 8am-8pm • Sat-Sun 10am - 6pm (EST) - 1 -

VOLT® Regal Path & Area Light

VPL-1012-BBZ Package Contents Product Dimensions INSTALLATION INSTRUCTIONS A. (1) Fixture Body B. (1) Fixture Hood w w w . v o l t l i g h t i n g . c o m [email protected] • 813.978.3700 9” 3” 25.5” C. (1) Inner Shade D. (1) Stake Parts Required A. (1) LED Bulb - 2 - - 3 - Important: Please Read Before Installation IMPORTANT SAFETY INSTRUCTIONS This luminaire is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty. These instructions do not intend to cover all variations in installation, operation maintenance or mounting situation. 1.  Make sure that the power is turned OFF before installing or servicing this luminaire. 2.  WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M) or more from pool, spa or fountain. 3.  This luminaire is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts. 4.  Wiring connections must be made with UL Listed wire connectors that are suitable for outdoor use. 5.  Position the low voltage wire and wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire or fitting. 6.  The main low voltage cable is intended for shallow burial - less than 6 inches (152 mm) 7.  If additional lengths of low voltage cable is required, please contact www. voltlighting.com or call 1-813-978-3700. INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS Lighted lamp is HOT! WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS. 1.  Turn off/unplug and allow to cool before replacing lamp. 2.  Lamp gets HOT quickly! Contact only switch/plug when turning on. 3.  Do not touch the hot lens, guard or enclosure. 4.  Keep lamp away from materials that may burn. 5.  Do not touch lamp at any time. Use a soft cloth. Oil from skin may damage lamp. 6.  Do not operate the luminaire fitting with a missing or damage shield. SAVE THESE INSTRUCTIONS ! !

w w w . v o l t l i g h t i n g . c o m

VOLT® Regal Path & Area Light VPL-1012-BBZ [email protected] • 813.978.3700 Install Fixture Body to Stake 5 Fixture Body Stake Pigtail Wireway Slot Remove Hat and Inner Shield 2 Remove the finial and the hat from the inner shield. Pull the inner shield off of the fixture body to expose the socket. Finial Fixture Body Inner Shield Install Lamp 3 Insert the bulb with the correct wattage and type marked on the fixture label. CAUTION: Do not exceed maximum wattage marked on luminaire label. NOTE: DO NOT touch bulb with bare hands. Use a soft cloth to handle bulb. Socket Bulb Install Stake 1 Board Stake Soil Ground - 4 - - 5 - Install Hat and Inner Shield 4 Push the inner shade onto the fixture body. Place the hat back onto the inner shield and secure with the finial previously removed. Hand tighten. Hat Fixture Body Inner Shield Determine the desired location for mounting the fixture. Hammer the stake into ground until flange of stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering. NOTE: If the ground is hard and the stake is difficult to install, make a crosscut in ground using a flat shovel. Clear away area in the ground at the wireway slot on top of the stake. Lay the luminaire pigtail into the wireway slot and thread the stem into the stake. Tighten to secure the base. Hat Finial

w w w . v o l t l i g h t i n g . c o m

VOLT® Regal Path & Area Light VPL-1012-BBZ Install/Replace Bulb Please refer to Step 2 - Step 4 to expose the Lamp and replace it with the correct wattage and type marked on the fixture label. IMPORTANT: LED Lamp must be protected from moisture and dust at all times. Always reinstall lens when removed. - 6 - Wire Connection 6 Pigtail Main Supply Cable Wire Connectors Strip both leads from the luminaire pigtail. Using two wire connectors (sold separately), connect the leads from the luminaire to the main low voltage supply cable leads.

- 8 -

Specifications and product details subject to change without notice. © Copyright 2019, VOLT® Lighting, Lutz FL USA 33549 • All rights reserved. [email protected] • 813.978.3700 w w w . v o l t l i g h t i n g . c o m Help Hotline: 1-813-978-3700 • Mon-Fri 8am-8pm • Sat-Sun 10am - 6pm (EST)

Other Landscape Lighting Manuals