Wilden H220 Engineering Operation & Maintenance Manual

File Specifications

Brand: Wilden
Category: Water Pump
Model: H220 (Engineering Operation & Maintenance Manual), proPdscupZECY
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 28 pages

Download PDF

Download Wilden H220 Manual (28 pages)

Read Online:

Read the Wilden H220 Engineering Operation & Maintenance Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

H220 High Pressure Bolted Metal

CONTENTS SECTION 1: Precautions – Read First! ..................................................................................................... 4 SECTION 2: Wilden Pump Designation System ...................................................................................... 5 SECTION 3: How It Works .......................................................................................................................... 6 SECTION 4: Dimensional Drawings ....................................................................................... ...

H220 High Pressure Bolted Metal

SECTION 8 H220 METAL – WETTED PATH LW0441 REV. B ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS EXPLODED VIEW AND PARTS LIST ...

H220 High Pressure Bolted Metal

SECTION 7 PUMP DISASSEMBLY Tools Required:  1/2" Wrench  9/16" Wrench  3/4" Wrench  1" Wrench  15/16" Wrench  5/64" Hex-Head Wrench  3/16" Hex-Head Wrench  O-Ring Pick  Adjustable Wrench  Snap-Ring Pliers  5/8"-18 Jam Nut 1/2" Socket  1" Socket  Torque Wrench CAUTION: Before attempting any maintenance or repair, disconnect the compressed air line to the pump and allow all air pressure to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allow ...

H220 High Pressure Bolted Metal

SECTION 4 H220 METAL DIMENSIONS ITEM METRIC (mm) STANDARD (inch) A 450 17.7 B 51 2.0 C 188 7.4 D 320 12.6 E 343 13.5 F 135 5.3 G 38 1.5 H 114 4.5 J 107 4.2 K 305 12.0 L 340 13.4 M 295 11.6 N 168 6.6 P 203 8.0 R 10 0.4 LW0440 REV. A DIMENSIONAL DRAWING DIMENSIONAL DRAWING ...

H220 High Pressure Bolted Metal

Copyright Copyright 2018 PSG®, a Dover Company. All rights reserved. PSG reserves the right to modify the information and illustrations in this document without prior notice. The product described in this document is furnished under a license agreement or nondisclosure agreement. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or mechanical, including photocopying and recording, without the written permission of PSG, a Dover Company, except as described by the terms of ...

H220 High Pressure Bolted Metal

Copyright Copyright 2018 PSG®, a Dover Company. All rights reserved. PSG reserves the right to modify the information and illustrations in this document without prior notice. The product described in this document is furnished under a license agreement or nondisclosure agreement. No part of this document may be reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or mechanical, including photocopying and recording, without the written permission of PSG, a Dover Company, except as described by the terms of ...

H220 High Pressure Bolted Metal

SECTION 5 H220 METAL TPE/FULL-STROKE PTFE-FITTED Ship Weight…………Ductile Iron 38 kg (84 lb) Stainless Steel 37 kg (81 lb) Air Inlet……………………..…….................1/2" Inlet…………………………………..25 mm (1") Outlet………………………………...25 mm (1") Suction Lift……………………2.8 m Dry (9.1') 9.0 m Wet (29.5') Disp. Per Stroke1…………...0.189 L (0.05 gal) Max. Flow Rate…………..93.9 lpm (24.8 gpm) Max. Size Solids…………………6.4 mm (1/4") 1Displacement per stroke ...

H220 High Pressure Bolted Metal

Troubleshooting Pump will not run or runs slowly. 1. Remove plug from pilot spool exhaust. 2. Ensure that the air inlet pressure is at least 0.4 bar (5 psig) above startup pressure and that the differential pressure (the difference between air inlet and liquid discharge pressures) is not less than 0.7 bar (10 psig). 3. Check air inlet filter for debris (see “Suggested Installation, Operation, Maintenance and Troubleshooting”). 4. Check for extreme air leakage (blow by) that would indicate worn seals/bores in the air valve, pilot spool and m ...

Wilden H220 user guide recommended for: Pro-Flo P2, Advanced Series, PS8 Saniflo HS Series, HX400S, PS Stallion Series.

⚠️ Download Safety

The Water Pump Engineering operation & maintenance manual (28 pages) is completely safe to download (last scan date: 27/04/2026).

Related PDF Instructions for Wilden H220:

Water Pump Equipment: Frequently Requested

Have some Questions about Wilden H220 Device?

Get valuable and actionable advices from other Wilden H220 device users. Describe your problem or question, regarding the using of H220, in as much detail as possible, and other users will be able to answer you.