Westlab 663-540 Operation & User’s Manual

Specifications

Brand: Westlab
Category: Microscope
Model: 663-540 (Operation & User’s Manual)
File Type: PDF
File Size: —
Pages: 9

Read Online

Read the Westlab 663-540 Operation & User’s Manual online using the built-in PDF viewer.

Text of the manual

1800 358 101 1300 725 903 [email protected] www.westlab.com.au

. WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED CODE 663-540 & 664-089 USER MANUAL INSTRUCTION MANUAL Before Use 1 1.Nomenclature 2 2.Operation 3 2-1 Set the Specimen Slide 3 2-2 Set Illumination 3 2-3 Adjust Focus 3 2-4 Adjust Diaphragm 3 2-5 Choose the Objective 3 2-6 Change the Lamp 3 3.General Specification 4 4.Parameter/Technical Terms 5 5.Troubleshooting 7 *Please read these instructions carefully before use.

As the microscope is a precision instrument, always handle

it with care, avoiding impact or abrupt movement during transportation. 2. MAINTENANCE (1.) All glass surfaces must always be kept clean. Fine dust on the optical surface should be blown off by means of a hand blower or gently wiped off with a soft lens tissue. Carefully wipe off oil or fingerprints on the lens surfaces with tissue moistened with a small amount of 3:7 mixture of alcohol and ether. (2.) Do not use organic solution to wipe the surface of the other components. These parts, especially the plastic parts, should be cleaned with a neutral detergent. (3.) Do not take down or assemble it yourself. (4.) After use, cover the microscope with the dustcover provided, and keep it in a dry and clean place for preventing rust. (2.) Do not let the microscope BE in the sunlight directly. Keep it in a dry and clean place. Avoid high temperature and acute shaking. Following environment is required: Indoor temperature: 0°C~40°C, Max relative humidity: 85%. (3.) Avoiding impact the definition of the image, do not leave feculence and fingerprints on the lens surfaces. (4.) Before using, examine to ensure that the power supply voltage is consistent with the rating voltage. 1 WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089 BEFORE USE

CODE 663-540 & 664-089

The microscope is housed in a moulded styrofoam container.

First take the container out of the carton, and lay the container on its side. Open the container carefully and don’t let the optical items drop down, avoiding them being damaged. Check carefully to ensure the arm and accessories are intact. Install the objective into the microscope nosepiece from the lowest magnification to the highest, in a clockwise direction from the rear. Insert the eyepiece into the eyepiece tube. 2-1 Set the specimen slide Place the specimen to be studied on a glass slide, and fix it with the slide-holder of the mechanical stage. If we use the movable specimen holder, fix the specimen by slide-holder of the movable specimen holder. Adjust its position by the switch of the movable specimen holder. 2-2 Set illumination 2-3 Adjust focus Adjust the coarse-focusing-knob to bring the slide into focus. Then lock the limit-stop-screw to avoid impact between the objective and slide. Adjust the fine-focusing-knob to get the image sharper and clearer. 2-4 Adjust diaphragm Turn the disc diaphragm to select a aperture to get the background brightness suitable. 2-5 Choose the objective 3 Turn the nosepiece to choose the objective. Objective selected should be set vertically right to the slide. Generally, first use the objective 4X to focus to reveal general structural image. Then use the high power objective to reveal smaller details. 2-6 Change the lamp Before changing the lamp, first pull the plug out off the electrical socket and wait for a while until the lamp cools down to avoid being burnt. Then screw off the base lens in an anti-clockwise direction and insert a new lamp and screw on the base lens. For the microscope with built-in electrical illuminator, insert the plug of the main cable into the power socket and turn on the light switch to get the specimen illuminated. 2. OPERATION WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089

BIOLOGICAL MICROSCOPE GENERAL

SPECIFICATIONS (FOR OPTIONS) Lamp Illumination Parts Specifications M-100F M-100FL Methylene Chloride WF10X/18mm WF10X/18mm with pointer WF10X/18mm with reticle WF15X/13mm WF20X/10mm • • Install 195 Objective 4X/0.10 10X/0.25 40XS/0.65 60XS/0.85 100XS/1.25(oil) • • • • • • Model H5X/ H6X H10X H12.5X H15X/ H16X Huygens Eyepiece Dual viewing head Monocular head 360°rotating Binocular head 360°rotating Metal base and stand Binocular head 360°rotating Metal base and stand 110mmX120mm Built-in movable stage 125mmX130mm Triple nosepiece Quadruple nosepiece Single N.A.0.65 AbbeN.A.1.25 Blue/Yellow/Green ф42mm mirror Built-in illuminator Five-aperture disc diaphragm Iris diaphragm LED Light Source 45°View Head Stand Polarized Set Nosepiece Stage Movable White Specimen Holder Clips Filter Condenser Diaphragm • • • • • • • • • • • • • • • • • • 4 WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089

4. PARAMETER/TECHNICAL TERMS

4-1 OBJECTIVE DIN achromatic objective 195mm 4x 10x 40x 60x 100x 0.10 0.25 0.65 0.85 1.25 45 45 45 45 45 Red Yellow Light blue Deep blue White Air Air Air Air Cedar oil Type Magnification Medium Numerical aperture (N.A) Parfocal distance (mm) Magnification market (color ring) 4-2 EYEPIECE 4-3 ELECTRICS The electrics are assembled according to customer’s order. There are two options: 4-4 PARAMETER (1) Total magnification: 20X~1600X (2) Field of view: ф0.08~ф4.5mm (3) Mechanical tube length: 160mm (4) Object to primary image distance: 195mm 220V~240V power supply : 220V~240V±10%, 50/60Hz Lamp: 220V/20W tungsten lamp The electrics have gained the CE and GS certification. 100V~120V power supply : 100V~120V±10%, 50/60Hz Lamp: 110V/20W tungsten lamp The electrics have gained the UL certification. 5 Magnification 10x 15x 20x 5x/6x 10x 12.5x 15x/16x Field of view (mm) ф18 ф13 ф11 ф15 ф12 ф10 ф8 Type Wide field Huygens WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089

4. PARAMETER/TECHNICAL TERMS

4-5 TECHNICAL TERMS (1) Total magnification=(magnification of objective) X (magnification of eyepiece) (2) Field of view=(line field of view of the eyepiece selected) ÷(magnification of the objective selected) (3) N.A.=n·sinα (max), N.A.is very important parameter which marks the features of the objective and condenser. The “n” is the refractive index of the medium (air or immersion oil) between the cover glass of the objective and the specimen. The “α” is the half of the aperture angle. The N.A.is bigger, the resolution of the objective is higher. (4) Object to primary image distance: the distance between the object plane to the primary image plane. The conjugate distance is fixed. (5) Mechanical tube length: The distance between the objective shoulder and the ocular shoulder. WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089

(1)The side of

the field of view is dark or not even The nosepiece is not in the right position Turn the nosepiece into the right position Clean the lens Stain or dust has accumulated on the condenser, objective, eyepieces, base, lens Symptom Cause (2)Stain or dust is observed in the field of view Stains have accumulated on the specimen Clean the specimen Clean the lens Stains have accumulated on the lens (3)Unclear image No cover glass on the specimen slide Add the cover glass The cover glass is not standard Use a standard cover glass with thickness 0.17mm Remedy Make it face up Clean thoroughly Use immersion oil Get rid of the air bubble Use a correct one Adjust the iris diaphragm Clean lens Adjust the condenser The specimen faces down The immersion oil has accumulated on the dry objective The immersion oil is not used for oil objective 100XR Air bubble in the immersion Use wrong immersion oil The aperture is not opened to correct size Stains or dust has accumulated on the lens in the inlet of the head The condenser is not in the right position 4)One side of the field of view is dark or the image moves while focusing The specimen slide is not fixed Fix with clips Turn the nosepiece into the right position The nosepiece is not in the right position (5)The field of view is not bright enough The iris diaphragm is not bigger enough Adjust the iris diaphragm (6)The image color is not true No filter is used Use correct filter Adjust the condenser Clean lens The condenser is not in the right position Stain or dust has accumulated on the condenser, objective, eyepieces, base lens 7 WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089

Order online with our easy Express

Order form for fast, secure ordering. PHONE 1800 358 101 Speak to one of our friendly, efficient staff from 8.00am to 5.00pm Monday to Friday. EMAIL [email protected] 24 hours, 7 days a week convenience. FAX 1300 725 903 Order via fax and we will confirm your order and delivery details at the end of the day. ORDERING WITH WESTLAB IS EASY... 5. TROUBLESHOOTING (CONT) Optics Electrics (1) The image is not focused while using high power objective The cover glass faces down Place cover glass to face up Use a standard cover glass with thickness of 0.17mm The cover glass is not standard Symptom Cause (2) The objective touches the cover glass when turning the nosepiece The cover glass faces down Put the cover glass to face up Use a standard cover glass with thickness of 0.17mm The cover glass is not standard (3) Cannot move the slide smoothly The slide is not fixed correctly Adjust it correctly Remedy Tighten it The movable specimen holder is not fixed properly (2)The bulb burnt out usually The voltage is too high Use correct power supply (3)The fuse burnt out usually The bulb will burn out soon The wire doesn’t connect all right Replace with a new one Connect correctly Replace with a correct one Use a wrong bulb (1)The bulb does not work No power supply Check the connection of the power cable Tighten it The bulb is not inserted correctly Replace it The bulb burnt out Replace it The fuse burnt out 8 WESTLAB EXTREME MONOCULAR MICROSCOPE, RECHARGEABLE, LED USER MANUAL CODE 663-540 & 664-089