Security Brands Edge E3 Quick Start Manual

Text of the manual

1 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) 1 2 WARNING   CAUTION   3 Unpack box and make sure you have all items shown here. (Screwdriver not shown.) Unlock and open front panel of unit for mounting, wiring, and setup. AUTOMATIC GATES CAN CAUSE SERIOUS INJURY OR DEATH! ALWAYS CHECK THAT THE GATE PATH IS CLEAR BEFORE OPERATING! REVERSING OR OTHER SAFETY DEVICES SHOULD ALWAYS BE USED! Edge Unit (HID version shown) Key Carriage Bolt ( 4x ) Hex Nut ( 4x ) 12-V AC/DC Adapter (PS-12DC1) Mount unit to pedestal using included mounting hardware. (This step may be completed later.) Continued on next page... Use all four carriage bolts when mounting the unit to a pedestal. Leave the antenna in place. Seal all openings created in the enclosure. Failure to follow these instructions can damage the unit and/or cause it not to function correctly!

© 2021 Security Brands, Inc. All rights reserved.

2 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) Model 27-230 (HID, SK) What’s what? All important components labeled Unit shown with front panel open. Wiring/cabling not shown for clarity. Wiegand Terminals For wiring to Wiegand devices See Page 6 Reset Button For performing unit reset Power, Relay, Event Terminals For wiring to power, wiring to gate operator or door opener, and connecting request-to-exit devices See Pages 3 and 5 Relay Status LEDs Relay is active when lit Digital Input Terminals For connecting various accessories See Page 5

3 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) 4 CAUTION   If the included 12-V AC/DC adapter will not be used, please go to Page 4 and follow the procedure, Using a Third-Party Power Source. Do not exceed 24 VAC/DC! Failure to choose a compatible power source can damage the unit! Connect wires. Feed wires through back of unit, and connect as shown using included screwdriver. Excessive force can damage unit! RELAY A J10 RELAY B J11 12–24 VAC/DC POWER J3 J17 J5 EVENT INPUTS Edge Power, Relay, Event Terminals Gate Operator / Door Opener POWER (+) POWER (–) COM RADIO COM REVERSE LOOP STOP CLOSE The GROUND terminal is optional unless required by local code(s). If using, please connect to earth ground or equivalent. 12-V AC/DC Adapter (Model PS-12DC1 included) Relay B can be wired to a second device in the same manner. FREE EXIT COM N/C N/C COM N/O GND EVNT2 GND EVNT1 Consult gate/door opener manual for exact connections. Terminals vary widely across manufacturers and models. If plugging into duplex outlet, remove screw from outlet plate, and secure with included screw. Additional wiring diagrams can be found on Pages 5 and 6. + – Third-Party 12–24-VAC/DC Power Source POS. (+) NEG. (–) OR COM N/O COM OPEN

© 2021 Security Brands, Inc. All rights reserved.

4 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) Model 27-230 (HID, SK) 4a 4b IMPORTANT r r CAUTION   STOP   6 7 5 If you would like to use a third-party power source such as solar, verify that it conforms to the following specs: Connect wires to unit as shown in Step 4. Connect wires to your power source, making sure you connect positive to positive and negative to negative. Double check that you have wired from positive on the Edge unit to positive on your power source and negative on the Edge unit to negative on your power source. Reverse polarity can damage the unit! Input 12–24 VAC/DC no more than 10% beyond this range Current Draw less than 111 mA @ 12 VDC less than 60 mA @ 24 VDC Using a Third-Party Power Source (Optional) Before going forward, double check all wiring and make sure the unit has power! Wiring diagrams for connecting to accessory devices can be found on Pages 5 and 6. For connecting accessories not mentioned, please contact Technical Support. Make sure the gate or door path is clear before completing Step 7! Add Access Code to Relay A. (To add multiple codes, enter each of them before pressing pound key.) Make sure gate or door path is clear; then enter access code on keypad, and confirm gate or door opens. Jump to Page 7 to continue programming and download the Edge Smart Keypad app. INSTALLATION COMPLETE! N 1 1 1 2 5 ? ? ? ? Access Code to Be Added (4 digits by default; numbers only) Master Code (can be changed) Sub Mode Close front panel of unit and lock it. NOTE: The green arrow indicates a “good” tone on the Edge unit. By default, the following codes are reserved and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985.

5 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) B A J8 J9 Edge Digital Input Terminals #2 GND #1 GND Digital Inputs Wiring to various accessories DIGITAL INPUTS Request-to-Exit Device (58-RTE-P is shown) Door Switch Event Inputs Wiring for accessories such as a request-to-exit device RELAY A J10 RELAY B J11 12–24 VAC/DC POWER J3 J9 J5 EVENT INPUTS Edge Power, Relay, Event Terminals N/C N/C COM N/O GND EVNT2 POS. (+) NEG. (–) COM N/O GND EVNT1 Alarm Contact To Alarm System Event Input configuration instructions can be found on Pages 10 and 11. Digital Inputs can be configured using the Edge Smart Keypad app.

© 2021 Security Brands, Inc. All rights reserved.

6 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) Model 27-230 (HID, SK) C CAUTION   J6 J7 J4 J5 Edge Wiegand Terminals UNAVAILABLE WIEGAND-1 DOOR/READER WIEGAND-2 Wiegand Device WIEGAND OUTPUTS +12V GND LED 1 LED 2 DATA 0 DATA 1 Disconnect power to the Edge unit before connecting Wiegand devices. Failure to disconnect power can damage the unit! Wiegand Device Wiring for a Wiegand device Wiegand 1 Terminals Connected to Onboard Proximity Card Reader GND LED2 LED1 DAT0 DAT1 +12V Wiegand programming instructions can be found starting on Page 14.

7 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) a b c D NEED HELP   Grab your smartphone or tablet. (These steps are optional. Unit can be fully programmed from keypad.) Navigate to your app store, and search for “edge smart keypad.” Find the Edge Smart Keypad app by Security Brands, Inc. and download it. Edge Smart Keypad Security Brands, Inc. Downloading the Edge Smart Keypad App for iOS/Android Pairing Edge Unit r The Edge Smart Keypad app is for ADMINISTRATOR USE ONLY and is not intended for users. You can find plenty of useful resources online to help you get your new Edge unit up and running quickly and easily. Go to securitybrandsinc.com/edge/ If you need further assistance, please call Technical Support at (972) 474-6390.  For more information and guidance, please go to securitybrandsinc.com/edge/ or call Technical Support at (972) 474-6390 for assistance. Connecting your mobile device to your Edge unit for use with app. The app is available for administrators who want to use it. Nearly all functionality is available through direct programming via the keypad.  IMPORTANT! Make sure your Edge unit is powered on and that Bluetooth is enabled on your mobile device or pairing will not work. Step 1 - Grab your mobile device and open the Edge Smart Keypad app. If you do not have the app, follow the steps on this page for downloading it. Step 2 - Fill out your account information and tap the “Sign Up” button. If you have already created an account, you will log in instead. Step 3 - On the Paired Keypads screen, tap the “Add Keypad” button. Step 4 - On the Add Keypad screen, tap the Edge unit you want to pair. If you do not see any Edge units listed, make sure your Edge unit is powered on and is in Bluetooth range. Step 5 - Complete the procedure shown on your mobile device. These steps will be completed using the PIN pad on your Edge unit. Step 6 - Enter the Master Code (default is 1251) on your mobile device. Step 7 - Enter the code shown on your mobile device at the Edge unit. This step must be completed within the time duration displayed. Step 8 - Change your Master Code if you like. This step is recommended, but optional, and can be done at a later time. Your new Edge unit is now be paired and will appear on the Paired Keypads screen. Tapping on the Edge unit on this screen will give you access to relay control and full access control management of the Edge unit from within the app.

© 2021 Security Brands, Inc. All rights reserved.

Model 27-230 (HID, SK) 8 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) E1 Direct Programming / Unit Configuration The Star Key (*) If a mistake is made, pressing the star key deletes your entry. Two beeps will sound. The Pound Key (#) The pound key is good for one thing and one thing only: exiting programming mode. Things to Know Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985. Sub Mode 3 1 1 2 5 ? ? ? ? New Master Code (4 digits; numbers only) Current Master Code (1251 is default) Sub Mode A Sub Mode B 4 4 1 1 2 5 ? ? ? ? Sleep Code (4 digits; numbers only) Master Code (1251 is default) Change Sleep Code Change Master Code (Highly recommended for security purposes) Programming Sub Modes 1 Add Access Code(s) to Relay A 2 Delete Code (Non-Wiegand) 3 Change Master Code 4 - 3 Add Latch Code to Relay B 4 - 4 Change Sleep Code 4 - 5 Change Code Length (Non-Wiegand) 4 - 6 Change Relay Trigger Time 4 - 7 Enable/Disable Timers and Schedules 4 - 8 Enable/Disable “3 Strikes, You’re Out” 4 - 9 Configure Event Input 1 5 Add Latch Code to Relay A 6 Configure Wiegand Inputs 7 Add Access Code(s) to Relay B 8 Add Limited-Use Code 0 Delete All Codes and Timers FIND MORE   For all programming not shown here, as well as reset procedures and the Edge Smart Keypad app user guide, please visit our Edge start page: securitybrandsinc.com/edge/

9 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) E2 Direct Programming / Unit Configuration Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. Current State (On: 1 beep; Off: 2 beeps) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 8 4 # Configure (1 for no change; 2 to change state) ? Enable/Disable “3 Strikes, You’re Out” (When enabled, the unit will sound an alarm and go into a 90-second lockdown for 90 seconds when an incorrect code is entered three times. Current State (On: 1 beep; Off: 2 beeps) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 7 4 # Configure (1 for no change; 2 to change state) ? Enable/Disable Timers and Schedules Change Relay Trigger Time Sub Mode A Sub Mode B 6 4 1 1 2 5 ? ? Master Code (1251 is default) ? ? ? Trigger Time in Seconds (001–999) Relay (1 for A; 2 for B) Sub Mode A Sub Mode B 5 4 1 1 2 5 ? Master Code (1251 is default) ? ? Code Length (04–11) Change Code Length  IMPORTANT! THIS WILL DELETE ALL NON-WIEGAND ACCESS AND LATCH CODES! 1 2 5 1 Master Code Again (1251 is default)

© 2021 Security Brands, Inc. All rights reserved.

10 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) Model 27-230 (HID, SK) E3 Direct Programming / Unit Configuration Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. Current State (Unit beeps mode number or good tone when disabled) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 9 4 Event Mode (1, 3, 4) ? # ? Relay (1 for A; 2 for B) Modes 1, 3, and 4 Configure Event Input 1 (Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.) Mode 1 - Remote Open Mode Triggers either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C). Mode 2 - Log Mode Makes log entry of event input state when event input state changes from normally open (N/O) to normally closed (N/C). Mode 3 - Remote Open and Log Mode Combines Modes 1 and 2. Mode 4 - Arming Circuit Mode Enables either Relay A or Relay B when event input state changes from normally open (N/O) to normally closed (N/C). Otherwise, selected relay is disabled. Mode 5 - Remote Operation Mode Triggers or latches either Relay A or Relay B when event input state changes from normally closed (N/C) to normally open (N/O). Mode 0 - Event Input 1 Disabled Sub Mode A 6 1 1 2 5 3 ? Master Code (1251 is default) Toggle Silent Mode (Toggles Silent Mode, which mutes all audible-tone feedback on unit) 9 0 Sub Mode B ? ? ? Master Code Again (1251 is default)

11 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) E4 Current State (Unit beeps mode number or good tone when disabled) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 9 4 Event Mode 5 ? Setting (1 for Relay; 2 for Relay Operation) # ? Relay (0 for A; 1 for B) # ? Relay Operation (0 for trigger; 1 for latch) Current State (Unit beeps mode number or good tone when disabled) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 9 4 # Event Mode 0 Current State (Unit beeps mode number or good tone when disabled) 1 1 2 5 Master Code (1251 is default) Sub Mode A Sub Mode B 9 4 # Event Mode 2 Mode 5 Mode 2 Disable Event/Digital Inputs (Mode 0) Configure Event Input 1 (continued) (Allows an external device to affect keypad operation or trigger a relay. To configure additional inputs, use the Edge Smart Keypad app.) Direct Programming / Unit Configuration Green arrow indicates “good” tone on unit. Always wait for good tone before moving on.

© 2021 Security Brands, Inc. All rights reserved.

12 of 20 QUI CK START G UIDE QSG-27230-EN Rev. B (2/2021) Model 27-230 (HID, SK) F1 E5 Direct Programming / Onboard Keypad Sub Mode 7 1 1 2 5 ? ? ? ? Access Code(s) to Be Added (4 digits by default; numbers only) Master Code (1251 is default) Add Access Code(s) to Relay B (To add multiple codes, enter each of them before pressing pound key) Direct Programming / Unit Configuration Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. Configure Wiegand Input (Allows enabling or disabling of a Wiegand input and configuration of the Wiegand device type. For the tag reader type, use the Edge Smart Keypad app.) Sub Mode A Wiegand Input (1 for 1; 2 for 2) ? 6 1 Configuration (0 for disabled; 1 for keypad; 2 for card reader; 3 for remote) ? # 1 2 5 Master Code (1251 is default) 0 5 0 Sub Mode B Sub Mode A 6 1 1 2 5 1 Master Code (1251 is default) Change Default Facility Code 6 0 Sub Mode B ? ? ? Facility Code (000–255) Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.

13 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) F2 Direct Programming / Onboard Keypad Sub Mode 2 1 1 2 5 ? ? ? ? Code to Be Deleted (4 digits by default; numbers only) Master Code (1251 is default) Delete Code (Non-Wiegand) Sub Mode A Sub Mode B 3 4 1 1 2 5 ? ? ? ? Latch Code to Be Added (4 digits by default; numbers only) Master Code (1251 is default) Add Latch Code to Relay B Sub Mode 5 1 1 2 5 ? ? ? ? Latch Code to Be Added (4 digits by default; numbers only) Master Code (1251 is default) Add Latch Code to Relay A ? ? Add Limited-Use Code (Access codes can be given a use or time restriction. For more advanced time restrictions, use the Edge Smart Keypad app.) ? ? ? Code to Be Added (4 digits by default; numbers only) Sub Mode Restriction Type (1 for uses; 2 for time) ? 8 1 1 2 5 ? Uses/Time (01–99 uses or 01–24 hours) Master Code (1251 is default) Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. By default, these codes are unavailable for use: 1251, 1273, 1366, 1381, 1387, 1678, 1752, 1985.

© 2021 Security Brands, Inc. All rights reserved.

14 of 20 QSG-27230-EN Rev. B (2/2021) QUI CK START G UIDE Model 27-230 (HID, SK) G1 Direct Programming / External Wiegand Keypad Sub Mode A 6 1 Sub Mode B 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) Add Wiegand Keypad Access Code(s) (Uses default facility code; to add multiple codes, enter each of them before pressing pound key) ? ? ? Relay (100 for A; 104 for B) Sub Mode A Wiegand Input (1 for 1; 2 for 2) ? 6 1 Sub Mode B 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) ? ? ? Relay (100 for A; 104 for B) On Wiegand Input 1 or 2 On Both Wiegand Inputs Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. Sub Mode A 6 1 Sub Mode C 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) Add Wiegand Keypad Manager Access Code(s) (Uses default facility code; to add multiple codes, enter each of them before pressing pound key) 1 1 0 Sub Mode B Sub Mode A Wiegand Input (1 for 1; 2 for 2) ? 6 1 Sub Mode C 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) 1 1 0 Sub Mode B On Wiegand Input 1 or 2 On Both Wiegand Inputs

15 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) G2 Direct Programming / External Wiegand Keypad Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. Sub Mode A 6 1 Sub Mode B 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) Add Wiegand Keypad Latch Code(s) (Uses default facility code; to add multiple codes, enter each of them before pressing pound key) ? ? ? Relay (103 for A; 105 for B) Sub Mode A Wiegand Input (1 for 1; 2 for 2) ? 6 1 Sub Mode B 1 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits by default; numbers only) Master Code (1251 is default) ? ? ? Relay (103 for A; 105 for B) On Wiegand Input 1 or 2 On Both Wiegand Inputs Sub Mode A 6 1 Sub Mode C 1 ? 1 2 5 ? ? ? ? Code(s) to Be Deleted (5 digits by default; numbers only) Master Code (1251 is default) Delete Wiegand Keypad Code(s) (Uses default facility code; to delete multiple codes, enter each of them before pressing pound key) 0 2 0 Sub Mode B Sub Mode A Wiegand Input (1 for 1; 2 for 2) ? 6 1 Sub Mode C 1 ? 1 2 5 ? ? ? ? Code(s) to Be Deleted (5 digits by default; numbers only) Master Code (1251 is default) 0 2 0 Sub Mode B On Wiegand Input 1 or 2 On Both Wiegand Inputs

© 2021 Security Brands, Inc. All rights reserved.

16 of 20 QSG-27230-EN Rev. B (2/2021) QUI CK START G UIDE Model 27-230 (HID, SK) H1 Direct Programming / Wiegand Card Reader Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. ? ? ? Sub Mode A Wiegand Input (1 for 1; 2 for 2; skip for both) ? 6 1 Sub Mode B 2 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits; 00000 to 65535) Master Code (1251 is default) Add Wiegand Card/Remote/Vehicle Tag Access Code(s) (To add multiple codes, enter each of them before pressing pound key) Facility Code ? ? ? Relay (100 for A; 104 for B) ? ? ? ? ? ? Sub Mode A ? 6 1 Sub Mode B 3 ? 1 2 5 ? ? ? ? Starting Code (5 digits; 00000 to 65535) Master Code (1251 is default) ? ? ? ? ? Ending Code (5 digits; 00000 to 65535) Bulk Add Wiegand Card/Remote/Vehicle Tag Access Code(s) Relay (100 for A; 104 for B) Facility Code Wiegand Input (1 for 1; 2 for 2; skip for both)

17 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) H2 Direct Programming / Wiegand Card Reader Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. ? ? ? Sub Mode A Wiegand Input (1 for 1; 2 for 2; skip for both) ? 6 1 Sub Mode B 2 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits; 00000 to 65535) Master Code (1251 is default) Add Wiegand Card/Remote/Vehicle Tag Latch Code(s) (To add multiple codes, enter each of them before pressing pound key) Facility Code ? ? ? Relay (103 for A; 105 for B) ? ? ? ? ? ? Sub Mode A ? 6 1 Sub Mode B 3 ? 1 2 5 ? ? ? ? Starting Code (5 digits; 00000 to 65535) Master Code (1251 is default) ? ? ? ? ? Ending Code (5 digits; 00000 to 65535) Bulk Add Wiegand Card/Remote/Vehicle Tag Latch Code(s) Relay (103 for A; 105 for B) Facility Code Wiegand Input (1 for 1; 2 for 2; skip for both)

© 2021 Security Brands, Inc. All rights reserved.

18 of 20 QSG-27230-EN Rev. B (2/2021) QUI CK START G UIDE Model 27-230 (HID, SK) H3 Direct Programming / Wiegand Card Reader Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. ? ? ? Sub Mode A Wiegand Input (1 for 1; 2 for 2; skip for both) ? 6 1 Sub Mode C 2 ? 1 2 5 ? ? ? ? Code(s) to Be Added (5 digits; 00000 to 65535) Master Code (1251 is default) Add Wiegand Card/Remote/Vehicle Tag Manager Access Code(s) (To add multiple codes, enter each of them before pressing pound key) Facility Code 1 1 0 Sub Mode B ? ? ? 1 1 0 Sub Mode A ? 6 1 Sub Mode C 3 ? 1 2 5 ? ? ? ? Starting Code (5 digits; 00000 to 65535) Master Code (1251 is default) ? ? ? ? ? Ending Code (5 digits; 00000 to 65535) Bulk Add Wiegand Card/Remote/Vehicle Tag Manager Access Code(s) Sub Mode B Facility Code Wiegand Input (1 for 1; 2 for 2; skip for both)

19 of 20

QUIC K S TART G UIDE Model 27-230 (HID, SK) H4 Direct Programming / Wiegand Card Reader Green arrow indicates “good” tone on unit. Always wait for good tone before moving on. ? ? ? Sub Mode A Wiegand Input (1 for 1; 2 for 2; skip for both) ? 6 1 Sub Mode C 2 ? 1 2 5 ? ? ? ? Code(s) to Be Deleted (5 digits; 00000 to 65535) Master Code (1251 is default) Delete Wiegand Card/Remote/Vehicle Tag Manager Code(s) (To add multiple codes, enter each of them before pressing pound key) Facility Code 0 2 0 Sub Mode B ? ? ? 0 2 0 Sub Mode A ? 6 1 Sub Mode C 3 ? 1 2 5 ? ? ? ? Starting Code (5 digits; 00000 to 65535) Master Code (1251 is default) ? ? ? ? ? Ending Code (5 digits; 00000 to 65535) Bulk Delete Wiegand Card/Remote/Vehicle Tag Code(s) Sub Mode B Facility Code Wiegand Input (1 for 1; 2 for 2; skip for both)

© 2021 Security Brands, Inc. All rights reserved.

20 of 20 QSG-27230-EN Rev. B (2/2021) QUI CK START G UIDE Model 27-230 (HID, SK) Call (972) 474-6390 Email [email protected] We are available Mon–Fri / 8am–5pm Central Edge E3 27-230HID Notes