Vicon LOCK STUDIO Quick Start Manual

Specifications

Brand: Vicon
Category: Cables and connectors
Model: LOCK STUDIO (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 8

Read Online

Read the Vicon LOCK STUDIO Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Quick Start Guide — Revision 4.0

For use with Vicon Lock Studio 1.0 Vicon Motion Systems Limited reserves the right to make changes to information in this document without notice. Companies, names, and data used in examples are fictitious unless otherwise noted. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic or mechanical, by photocopying or recording, or otherwise without the prior written permission of Vicon Motion Systems Ltd. Vicon® is a registered trademark of Oxford Metrics plc. Vicon Bonita™, Vicon Lock+™, Vicon Lock Lab™, Vicon Lock Studio™, Vicon Nexus™, Vicon Shōgun™, Vicon Tracker™, Vicon Vantage™, Vicon Vero™ and Vicon Vue™ are trademarks of Oxford Metrics plc. VESA® is a registered trademark owned by VESA (www.vesa.org/about-vesa/). Portions of the software were initially developed by Lucent Technologies Inc., and are subject to the terms of Lucent Public License Version 1.02 (https://opensource.org/licenses/LPL-1.02). All software distributed under such Agreement is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY KIND, either express or implied. See the Lucent Public License for the specific language governing all rights, obligations and limitations under such Agreement. Portions of the software developed by Lucent Technologies Inc. are Copyright © 1999–2003. All rights reserved. Contributor: Vicon Motion Systems Ltd. Part of the software embedded in this product is eCos (Embedded Configurable Operating System), a registered trademark of eCosCentric Limited. eCos is released under a modified version of the GNU General Public License (GPL) (http://ecos.sourceware.org/license-overview.html) Copyright © 2007 Free Software Foundation, Inc. (www.fsf.org). Other product and company names herein may be the trademarks of their respective owners. © Copyright 2018–2021 Vicon Motion Systems Limited. All rights reserved. Vicon Motion Systems is an Oxford Metrics plc company. Email: [email protected] Web: www.vicon.com LOCK STUDIO QUICK START GUIDE Connect. Integrate. Synchronize.

B E Y O N D M O T I O N

Page 2 Vicon Motion Systems • • • • • Introducing Lock Studio Lock Studio is a connectivity device from Vicon, offering a cost-effective and silent solution for providing synchronization and timecode to your Vicon Vero and Vicon Vantage systems (Vicon Bonita and MX T-Series systems are also supported). Lock Studio features: Timecode and genlock, including genlock to SD, HD and 3G SDI broadcast digital video signals, and extracting timecode metadata Support of VESA standards Remotely triggered start and stop General Purpose Input and Output (GPIO) sockets for synchronizing external devices Sync to SteamVR for use with HTC Vive Lock Studio front view Status light (front) On the front of the Lock Studio, the Vicon logo illuminates to indicate status. Color Status Red Booting Green Booted but not connected Blue Communicating with software Cyan Lock Studio selected in software Lock Studio rear view Connections (rear) Link input/output (I/O) PoE Earthing (grounding) point SDI input Analog video reference input including VITC Timecode input: LTC VESA sync input Timecode output: LTC VESA sync output Remote Control input start and stop GPO sync outputs (x8)

B E Y O N D M O T I O N

Vicon Motion Systems Page 3 Connection details Link I/O. For Lock to Lock synchronization. Also provides Lock Studio to legacy Giganet synchronization. Connect to Vicon equipment only. PoE (conforms to IEEE 802.3af). Requires connection to a Gigabit (Ethernet 1000BASE-T) PoE router. Use only the supplied cable. Earthing point. Always ground the Lock Studio using this dedicated earthing point. SDI (Serial Digital Interface) input. Fixed 75 Ω terminated BNC input for connecting to Standard Definition (SD), High Definition (HD) and 3G SDI broadcast digital video signals. Used to genlock to external video broadcast signals and to extract embedded timecode data. Lock Studio can be phased with respect to the selected input broadcast signal in increments of 37 nS through a whole frame period. For more information, see Vicon Lock genlock support information. Analog video reference input, including VITC. Dual BNC sockets for connecting an external video source that transmits a composite video signal, including Vertical Interval Timecode (VITC), from the master video source to the Lock Studio and any other synchronized video or audio devices in a chain. The Lock Studio must be genlocked to this external video source. Timecode input: LTC. XLR socket for connecting an external source that transmits LTC (Longitudinal Interval Time Code) to the Lock Studio. LTC is supported at 23.98, 24, 25, 29.97 and 30 fps. Requires an accompanying synchronized genlock source. For more information, see Vicon Lock genlock support information. VESA sync input. 3-pin mini DIN socket. Current Vicon software supports 100Hz and 120Hz. After it is locked, Lock Studio can be phased with respect to this input signal in increments of 18 nS through a whole frame period. Also used for sync and connecting with HTC Vive via SteamVR. Timecode output: LTC. BNC socket that enables output of a single-ended LTC signal (23.98, 24, 25, 29.97 and 30 fps) through a 100 Ω resistor. VESA sync output. BNC socket. Current Vicon software supports 100Hz and 120Hz.This output signal can be phased with respect to the system sync (including the sync to Vicon cameras) in increments of 18 nS through a whole frame period. Remote Control input start and stop. RCA phono sockets for connecting a remote third-party device that triggers the Vicon system to capture data based on input signals. Start and stop are activated on next frame boundary. Requires connection to GND (ground). GPO sync outputs. Eight programmable phono (RCA) sockets for synchronizing external devices using General Purpose Output (GPO) signals. To manage synchronization of external devices, or to trigger them from Vicon system events, identify an appropriate GPO configuration file supplied with your Vicon software or create your own (see the Vicon Vantage Reference Guide). In your Vicon software, specify the GPO file for your device. Important: If the Lock Studio is the only device or the last device in a chain, the Ref Loop connection that is not used for signal output must be terminated in 75 Ω remotely or by using a 75 Ω terminator.  Note:  When inputting HD tri-sync standards (such as Film, NTSC Film, and 30 fps), LTC is required for timecode. 

B E Y O N D M O T I O N

Page 4 Vicon Motion Systems Vicon Lock Studio in a Vicon Vantage system System details correct at time of publication, but may now be superseded. For up-to-date information, visit the Vicon website and search for PC specification.

B E Y O N D M O T I O N

Vicon Motion Systems Page 5 • • Lock Studio regulatory and safety information These topics provide information on how Vicon Lock Studio complies with regulatory standards, including product recycling. The certification that Lock Studio has achieved for meeting stated international standards and Lock Studio safety information is also included. Radio and television interference (US and Canadian customers) Environmental regulations (EU customers) Radio and television interference (US and Canadian customers) This topic contains information concerning compliance with regulations of radio and television interference. For United States of America customers Federal Communications Commission (FCC) Part 15 Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules (CFR 47:Part 15:B:2013). These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Vicon Motion Systems Ltd is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For Canadian customers Conformity to the Canadian Interference-Causing Equipment Regulations This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations ICES-003:2004. Avis de conformité à la réglementation d'Industrie Canada Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada ICES-003:2004. Environmental regulations (EU customers) Restriction of the use of certain hazardous substances in electrical and electronic equipment – RoHS and recast (RoHS 2) This equipment is fully RoHS- and RoHS 2- compliant. RoHS Directive 2002/95/EC provides that new electrical and electronic equipment put on the market for the first time from 1st July 2006 should not contain lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBB), or polybrominated diphenyl ethers (PBDE). The European Union Directive 2011/65/EU provides that new electrical and electronic equipment put on the market for the first time from 3rd January 2014 shall not contain more than permitted levels of lead, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBB), or polybrominated diphenyl ethers (PBDE; PentaBDE, OctaBDE; DecaBDE), Mercury (Hg). REACH Declaration of Conformity Vicon Motion Systems Ltd is a manufacturer of electronic hardware. We are therefore considered a "downstream user" as far as the REACH document is concerned. Vicon Motion Systems Ltd is therefore not obligated to register with the European Agency for Chemicals 'ECHA'. Products sold by Vicon Motion Systems Ltd are "articles" as defined in REACH (Article 3 Definitions). Moreover and under normal and reasonably foreseeable circumstances of application, the articles supplied shall not release any substance. For that, Vicon Motion Systems Ltd is neither obligatory for registration nor for the creation of material safety data sheets. In order to assure our customers of the continual supply of reliable and safe products, we ensure that our suppliers fulfill all requirements regarding chemical substances and prepared materials. Waste Electrical and Electronic Equipment (WEEE) (Applicable in the European Union and other European countries with separate collection systems) The use of the symbol as a marking on the equipment, accessories or literature indicates that this product and its electronic accessories (e.g. USB cable) may not be treated as household waste. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. Household users should contact either the retailer where they purchased this device, or their local government office, for details of where and how they can take these items for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchasing contract. This device and its electronic accessories should not be mixed with other commercial waste for disposal.

B E Y O N D M O T I O N

Page 6 Vicon Motion Systems EU Declaration of Conformity - Lock Studio 1912 Declaration of Conformity Medical Devices Directive 93/42/EEC as amended by EU Council Directive 2007/47/EC of 5th September 2007 and Electromagnetic Compatibility to EMC Directive 2014/30/EU Electrical Safety to Low Voltage Directive 2014/35/EU We, Vicon Motion Systems Limited Unit 6, Oxford Industrial Park Mead Road, Yarnton, Oxford, OX5 1QU Declare that the VICON LOCK STUDIO providing analogue-digital conversion within the VICON Vantage or Vero Gait Analysis System manufactured by VICON MOTION SYSTEMS LIMITED meets ANNEX V and VII, Section 5 of the Medical Devices Directive 93/42/EEC in that the Quality Management System has been approved by Dare!! Services B.V., a notified body of the European Union (Reg No. 1912) for the manufacture and support of the aforementioned CLASS 1(m) Medical device. Product configurations and software options (Vicon Lock Studio) detail the product configurations and software options that conform to the metrological requirements of the Directive. This declaration of conformity is issued under the sole responsibility of the manufacturer. VICON MOTION SYSTEMS LIMITED has tested and demonstrated that all products of its own manufacture meet 2014/30/EU: Electromagnetic Compatibility to: EN60601-1-2:2007 General Requirements for Safety to: Lock Studio EN60601-1:2006 + A12:2014 Accessory Network Hub BS EN 62368-1:2014 + A11:2017 Software Development, Conformity and Support EN ISO 13485:2016 EN ISO 14971:2019 BS EN 62304:2006 + A1:2015, IEC 62304:2006/A1:2015 Thomas Shannon TD PhD FIE (Aust) CPEng (Biomed.) Director of Compliance 4th May 2021 Date of Expiration 17th August 2023 (Article 120, EU 2017/745), subject to meeting the continued surveillance obligations, Section 4, Annex V. Certificate Number 20M00097CRT05 8th September, 2020. Not for use in an operating theatre, anaesthetic gas or oxygen-rich environments. Not for use where there is a risk of compromising the essential performance of medical electrical equipment. Not suitable for use in high magnetic flux, ionizing radiation, sterile, or life- or safety-critical environments. Note: The overall installed system classification is defined by the highest risk device connected which may include the connection of approved third-party equipment such as electromyography apparatus by clients.

B E Y O N D M O T I O N

Vicon Motion Systems Page 7 • • • • • • • • • • Product configurations and software options - Vicon Lock Studio This page provides information relating to the EU Declaration of Conformity (Vicon Lock Studio). Conformity of the Metrological Performance of CLASS 1 Products Manufactured in Accordance with Annex VII, Section 5 of the Medical Devices Directive 93/42/EEC of the 14th June 1993 As amended by EU Council Directive 2007/47/EC of 5th September 2007 We, Vicon Motion Systems Limited Unit 6, Oxford Industrial Park Mead Road, Yarnton, Oxford, OX5 1QU UNITED KINGDOM declare that the VICON LOCK STUDIO providing analogue-digital conversion within the VICON Vantage or Vero Gait Analysis System manufactured by VICON MOTION SYSTEMS LIMITED has been tested prior to shipment and meets the following metrological performance: Measurement Criteria Supporting software: Nexus 2.10 or later, Shogun 1.4 or later, Tracker 3.8 or later. Analogue Digital Conversion Resolution to ± 10 mV mean and ± 10 mV (1 Standard Deviation). Synchronization Difference within one video frame. Lock Studio safety information The following guidance helps you to ensure the safe operation of your Vicon system, including the use of Lock Studio. To avoid introducing a safety hazard and possibly damaging the system, please ensure that an adequate and good-quality alternating current (AC) power source is available. For guidance, see the ratings statement on the rear of the connected PoE or PoE+ unit. Also ensure that any computers and peripheral devices are set to be electrically rated to operate with the AC power available in your location. When working with Vicon systems, observe these safety precautions: To prevent electric shock, plug all system components into properly grounded power sources. These cables must be equipped with three-prong plugs to ensure proper grounding. Do not use adapter plugs or remove the grounding prong from a cable. Ensure nothing rests on the system cables and that cables are not located where they can be stepped on or tripped over. Do not spill food or liquids onto any electrical component of the system. If any component gets wet, immediately contact Vicon Motion Systems or your nearest agent or distributor for advice. Do not push any objects into the slots of any unit of the system. Doing so can cause fire or electric shock by shorting out internal components. Keep all system components away from radiators and heat sources, and do not block cooling vents. Avoid placing loose papers underneath any components. Do not place any components on closed-in units or on a bed, chair, etc. Replace fuses with the same type and rating for continued fire protection. Do not use outside, near water, in an environment exposed to anesthetic or other explosive gases, or in mobile applications. Warranty information The warranty for your Vicon system begins after installation. For full details on warranty scope and conditions, refer to the Vicon Terms and Conditions of Supply for your Vicon system.

B E Y O N D M O T I O N

Page 8 Vicon Motion Systems If you need more information than that supplied in the documentation or on the Vicon Support web pages, please contact  Vicon: Denver, CO Vicon Denver 7388 S. Revere Parkway Suite 901, Centennial CO 80112, USA T: 303.799.8686 F: 303.799.8690 E: [email protected] Los Angeles, CA Vicon LA 3750 S. Robertson Boulevard Suite 100, Culver City, Los Angeles CA 90232, USA T: 310.437.4499 E: [email protected] Oxford, UK Vicon Oxford Unit 6, Oxford Industrial Park Mead Rd, Yarnton, Oxford OX5 1QU, United Kingdom T: +44.1865.261800 E: [email protected] © Copyright 2021 Vicon Motion Systems. All rights reserved. Vicon trademarks

Other Cables and connectors Manuals