Topgreener TD0S5-J Installation Instructions

Text of the manual

Vacancy Mode: Manual On

only, automatic Off after set time delay. Mode Position INSTALLATION INSTRUCTIONS TD0S5-J OCCUPANCY/VACANCY (2-IN-1) SENSOR SWITCH Voltage ................................................................................120VAC,60Hz Incandescent ........................................................................................500W Fluorescent/Ballast..............................500VA@120VAC/1000VA@277VAC Motor ...............................................................................................1/4HP Time Delay .......................................................................15Sec to 30Mins Light Level. ........................................................................30 Lux--Daylight Operation Temperature ...........................................................32 Fà-131 F 0 The passive infrared sensor works by detecting the difference between heat emitted from the human body in motion and the background space. The sensor switch can turn a load on and hold it as long as the sensor detects occupancy. After no motion is detected for the set time delay, the load turned off automatically. The sensor switch has one relay (equal to single pole switch), also includes Ambient Light Level Sensor. Coverage Area The coverage range of the sensor switch is specified and illustrated in Figure 1. Large objects and some transparent barriers like glass windows will obstruct the sensor's view and prevent detection, causing the light to turn off even if someone is still in the detection area. - 01- Figure 1 Figure 2 Figure 3 -02- Description OFF Left Circuit is permanently opened. ( switched off) Center Occupancy Mode: Automatic On, automatic Off after set time delay. VAC Right Figure 4 Push-Button on Reaction None Manually toggles OnIOff load. Manually toggles On/Off the load. Time Delay knob Default position: 15 Seconds (Test mode) Adjustable: from 15 Seconds to 30 Minutes (clockwise) Sensor Sensitivity Range Knob Default position: Center at 65% Adjustable: 30% (Position 1) to 100% (Position 4) Note: Turn toward right for greater room space. Turn toward left to avoid false alert in smaller room and near the door way or heat source. -03- 1. 2. The black wires on the sensor are hot and load interchangeable. Connect lead wires as wiring diagram (see Figure 2): One Black lead to Hot or Load, The other Black lead to Load or Hot, Green lead to Ground. 3. Gently position wires in wall box, attach sensor switch to the box. 4. Mount device "TOP" up. 5. Restore power at circuit breaker or fuse. Wait three minutes for the sensor complete its initial run. Note: The sensor needs to be charged for 3 minutes in the first use. Please do not press any button and make any adjustment in this period of them for the sensor to work properly. 6. Remove the small cover plate. (Illustrated in Figure 3) 7. Locate the adjustment knobs on the control panel to test and change setting.(Illustrated in Figure 3) 8. Replace the small cover plate after testing and setting. 9. Attach the wallplate. DESCRIPTIONION IINSTALLATIONION SAFETY WARNING:: Read and understand these instructions before installation. This device is intended for installation in accordance with the National Electrical Code and local regulations. It is recommended that a qualified electrician perform this installation. Make sure to turn off the circuit breaker or fuse(s) and test that the power is off before wiring the device. Note: Green wire on the sensor must be connected to Ground or Neutral for the sensor to work properly. Wiring Diagram: ADJUSTMENT Band Switch Description OCC TDOS5-J SPECIFICATIONS Ambient Light Level Adjustment. Note: Please complete Initial Run (3 minutes) before adjusting ambient light level. 1. Set the Band Switch to VAC. Switch Type .................................................................................Single Pole

Use the band switch located under the control panel cover to select

the operation mode of the sensor switch. “OFF” mode powers off the entire sensor. “OCC” mode automatically turns the load on and off based on occupancy. “VAC” mode requires the load to be manually turned on and will automatically turn off the load based on occupancy. VAC mode can also be described as “Manual On Occupancy Mode”. Manual On/Off Button By Pressing the control panel cover, the Load can be turned On/Off under OCC or VAC mode. (Illustrated in Figure 5) Turning On the Load under Occupancy Mode Load will automatically turn on when occupancy is detected. Turning On the Load under Vacancy Mode Press switch cover to manually turn on the load. Automatically Turning Off the Load Under either mode, the Sensor will keep the Load on when no motion is detected for up to the set time delay before automatically turning off the load. Under VAC mode, the load will automatically turn back on if motion detected within the first 30 seconds. -04- Figure 5 1. It can take up to three minute for initial run to complete. 2. Check the wiring connections, especially the Ground Wiring. The Load does not turn on when motion is detected 1. There can be up to a 30 minutes time delay after the last motion detected. To verify proper operation, turn the Time Delay Knob to 15s (Test Mode), make sure there is no motion (no LED flashing), and the Load should turn Off in 15 seconds. 2. Check if there is any significant heat source mounted within six feet (two meters) that may cause false detection, such as a high wattage light bulb, portable heater, or HAVC device. 3. Check the wiring connections, especially the Ground wiring to the sensor switch. The Load turns on when there is no motion 1. Switch from OCC to VAC mode. 2. Cover the Sensor Switch's lens to eliminate unwanted coverage area. 3. Turn the Sensitivity Level knob to the left to avoid false alerts in smaller rooms and if installed near the door way. If within two(2) years from the date of purchase, this product fails due to a defect in material or workmanship, we will repair or exchange it, at its sole option free of charge. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to un-authorized repair, opened, taken apart or otherwise modified; (c) unit not used in accordance with instruction; (d) damages exceeding the cost of the product; (e) finish on any portion of the product, such as surface and weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or rein-installation costs. This warranty service is available by returning the product with proof of purchase, purchase date and a description of the problem to the dealer from whom the unit was purchased. April,2016 -06- WARRANTY INFORMATION To operate properly, the Sensor Switch consumes power from the hot and Ground. Therefore, a Secured Ground Wiring is required. Initial run The Sensor Switch requires an initial run of three minute. During the initial run, the load may turn on and off several times. Do not adjust any setting until the initial run has completed. The Load is out of control (frequently flashing) 1. Check to see if Ambient Light Level is enabled by covering the lens by hand. 2. Check the wiring connections, especially Hot and Ground wiring, and make sure there is no loose wiring. 2. Press and hold the Manual ON/OFF button (Figure 4) for 6 seconds until the load turns on, release in the next 4 seconds. The Load will turn off for 10 seconds. 3. The Load will turn on again for 2 seconds and then turn off. This confirms that the present light level is now the set Ambient Light Level. 4.Set the Band Switch to OCC mode. The Load will now turn on only when the present light level is below the Ambient Light Level setting and when motion is detected. Back to factory default(daylight). 1. Set the Band Switch to VAC. 2. Press and hold the Manual ON/OFF button (Figure 4) until the Load turns on, continue holding until the Load turns off. Release button. 3. Set the band Switch to OCC. The switch is now set to the factory default mode. The Load does not turn Off -05- Manually Turning Off the Load You can manually turn off the load in OCC or VAC mode by pressing the switch cover. In OCC mode, the sensor will take about 5 minutes to reactivate and will not respond to motion during this time. TROUBLESHOOTING OPERATION

Other Switch Manuals