Paradox Esprit 748 express + Programming Manual

Text of the manual

SOFTWARE VERSION 3.00

CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect a jumper between "reset jumper" pins. (3) Connect AC and/or battery. (4) Wait 3 seconds. (5) Remove jumper. Factory default installer and master codes will be reinstated. Values entered at addresses 008-043, 062-126 and 300-523 as well as all user codes, will be erased ([2ND] [2ND]). Programmed values of all other addresses do not change. HEXA PROGRAMMING: All digits from 0 to F are valid. Values are programmed into memory locations from address 000 to 043 and from address 300 to 523. 1) Press [ENTER] + installer code. 2) [ENTER] will flash (programming mode). 3) Enter 3 digit memory address. 4) Current value will be displayed on keypad. 5) Enter 2 digit data. 6) Go to step 3 for next address. To exit programming mode, press [CLEAR]. STREAMLINED SECTION PROGRAMMING Can be used to program sections 00 to 66. (addresses 000 to 043 and 300 to 523) Press [ENTER], installer code, and [7]. ([2ND] and [ENTER] keys alternately flash.) Enter a 2-digit section number, followed by 8 digits to program that section (confirmation beep). Data will be saved automatically and the software advances to the next programming section. To exit programming mode press [CLEAR]. INSTALLER CODE: (reset code 747474) (addresses 000, 001, 002) SECTION 00 Full access to programming, except access codes. (addresses 127-299) No access to arming/disarming. Can be used to modify installer code. Use only numeric keys from [1] to [10]. (key [10] = 0) PANEL ANSWER OPTIONS: (address 003) SECTION 00 First digit disables “Answering Machine Override” (key [2ND] or key [1]), or determines period of time between first and second call (see table below). Second digit determines number of rings required before panel will answer. If [2ND][2ND] is entered, panel will not answer. (Default value is [2ND] [8].) - 1 - Value of 2ND digit = 10 ( 8 + 2 = 10) Value of 1ST digit = 3 ( 2 + 1 = 3) VALUE = "3A" HEXA DISPLAY No display = SKIP (empty) No light = 0 10 = [0] = [A] If key is lit = 8 = 4 = 2 = 1 If key is lit = 8 = 4 = 2 = 1

TELEPHONE AND ACCOUNT NUMBERS: (reset empty)

If only one central station phone number is used, program the same number for telephone number 1 and 2. [10] = the number "0" [BYP] = switch from pulse to tone while dialing [11] = * [MEM] = pause 4 seconds [12] = # [TRBL] = end of number COMPUTER TELEPHONE NUMBER: (View at addresses 008 to 015.) 02 __ / __ / __ / __ / __ / __ / __ / __ 03 __ / __ / __ / __ / __ / __ / __ / __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CENTRAL STATION TELEPHONE NUMBER 1: (View at addresses 016 to 023.) 04 __ / __ / __ / __ / __ / __ / __ / __ 05 __ / __ / __ / __ / __ / __ / __ / __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CENTRAL STATION TELEPHONE NUMBER 2: (View at addresses 024 to 031.) 06 __ / __ / __ / __ / __ / __ / __ / __ 07 __ / __ / __ / __ / __ / __ / __ / __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ACCOUNT "A" AND "B": (View at addresses 032 to 035.) 08 ___ / ___ / ___ / ___ ___ / ___ / ___ / ___ 1 2 3 4 5 6 7 8 A B If only one account number is required, the same number must be entered for both account "A" and "B". - 2 - PG748EX Press [TRBL] to end phone number if less than 16 digits are programmed. Press [TRBL] to end phone number if less than 16 digits are programmed. For 3 digit account numbers, enter "skip" ([2ND]) as first digit. Press [TRBL] to end phone number if less than 16 digits are programmed. Streamline section Streamline section Streamline section Streamline section Streamline section Streamline section Streamline section

1st digit: value must be entered i.e.

2nd digit: time correction (See table) 1st digit: telephone 1 format 2nd digit: telephone 2 format 1st digit: PGM 1 type 2nd digit: PGM 2 type [2 ] ND 036 037 038 039 09 PGM 1 PGM 2 PGM mask 1 PGM mask 2 040 041 042 043 ___/___ ___/___ / ___/___ ___ ___ 10 TIME CORRECTION: (address 037 second digit) [2 ] [1] [2] [3] [4] [5] [6] [7] ND - No adjustment - Plus 4 sec. - Plus 8 sec. - Plus 12 sec. - Plus 16 sec. - Plus 20 sec. - Plus 24 sec. - Plus 28 sec. [8] [9] [10] [11] [12] [ ] [ ] [ ] - Minus 4 sec. - Minus 8 sec. - Minus 12 sec. - Minus 16 sec. - Minus 20 sec. - Minus 24 sec. - Minus 28 sec. - Minus 32 sec. BYP MEM TRBL COMMUNICATOR FORMATS Key [2 ] [1] [2] [3] [4] [5] ND [6] [7] [8] [9] [10] [ ] TRBL = slow (1400Hz, 1900Hz, 10bps) = (1400Hz, 1800Hz, 10bps) = fast (1400Hz, 1900Hz, 20bps) = (2300Hz, 1800Hz, 20bps) = (40bps with 1400Hz handshake) = (40bps with 2300Hz handshake) ADEMCO SILENT KNIGHT SESCOA RADIONICS RADIONICS = with PARITY (1400Hz, 40bps) = with PARITY (2300Hz, 40bps) = express = contact ID (programmable codes) = contact ID (all codes) = - no handshake (personal dialing) RADIONICS RADIONICS ADEMCO ADEMCO ADEMCO DTMF [2 ] ND - 3 - PG748EX For addresses to , see pages 7 to 10. 044 126 CID 100: 110: 111: 112: 113 114: 115: 116: 117: 118: 120: 121: 122: 123: 130: 131: 132: 133: 136: 137: 138: 140: 150: 151: 152: 153: 154: 155: 156: 157: 158: 159: 161: CID 300: 301: 302 305: 306: 309: 320: 321: 323: 350: 351: 354: 370: 371: 372: 373: 382: 383: 400: 401: 402: 403: 404: 407: 410: 441: 570: 572: 573: 574: 601: 602: 625: PROG. VALUE [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [2 ] [ ] [2 ] [ ] [2 ] [ ] [2 ] [ ] [ ] [ ] [2 ] ND ND ND ND ND ND ND ND ND ND ND ND ND BYP ND MEM ND TRBL ND BYP MEM TRBL ND / [1] / [2] / [3] / [4] / [5] / [6] / [7] / [8] / [9] / [10] / [11] / [12] / / / [1] / [1] / [1] [1] / [2] [1] / [3] [1] / [4] [1] / [5] [1] / [6] [1] / [7] [1] / [8] [1] / [9] [1] / [10] [1] / [11] [1] / [12] [1] / [1] / [1] / [2] / [2] / [1] PROG. VALUE [2] / [2] [2] / [3] [2] / [4] [2] / [5] [2] / [6] [2] / [7] [2] / [8] [2] / [9] [2] / [10] [2] / [11] [2] / [12] [2] [ ] [2] [ ] [2] [ ] [3] / [2 ] [3] / [1] [3] / [2] [3] / [3] [3] / [4] [3] / [5] [3] / [6] [3] / [7] [3] / [8] [3] / [9] [3] / [10] [3] / [11] [3] / [12] [3] [ ] [3] [ ] [3] [ ] [4] / [2 ] [4] / [1] [4] / [2] / / / / / / BYP MEM TRBL ND BYP MEM TRBL ND REPORTING CODE MEDICAL FIRE ALARM FIRE SMOKE COMBUSTION WATER FLOW HEAT PULLSTATION DUCT FLAME NEAR ALARM PANIC ALARM DURESS SILENT PANIC AUDIBLE PANIC BURGLARY PERIMETER BURG. INTERIOR BURG. 24HR BURGLARY BURGLARY OUTDOOR BURGLARY TAMPER BURGLARY NEAR ALARM GENERAL ALARM 24 HOUR AUX GAS DETECTED REFRIGERATION LOSS OF HEAT WATER LEAKAGE FOIL BREAK ALARM DAY TROUBLE ALARM LOW GAS LEVEL HIGH TEMPERATURE LOW TEMPERATURE LOSS AIR FLOW REPORTING CODE SYSTEM TROUBLE AC LOSS LOW SYSTEM BATTERY SYSTEM RESET PROGRAM CHANGED BATTERY TEST FAIL SOUNDER/RELAY TROUBLE BELL 1 TROUBLE ALARM RELAY TROUBLE COMMUNICATION TROUBLE TELCO 1 FAULT FAIL TO COMMUNICATE PROTECTION LOOP TROUBLE PROTECTION LOOP OPEN PROTECTION LOOP SHORT FIRE LOOP TROUBLE SENSOR TROUBLE SENSOR TAMPER OPEN/CLOSE OPEN/CLOSE BY USER # GROUP OPEN/CLOSE AUTOMATIC OPENING/CLOSING LATE TO OPEN/CLOSE REMOTE ARM DOWNLOAD REMOTE ACCESS OPEN/CLOSE - STAY MODE BYPASS 24 HOUR ZONE BYPASS BURGLARY BYPASS # GROUP BYPASS MANUAL TEST PERIODIC TEST TIME/DATE RESET PROGRAMMABLE CONTACT ID EVENT CODES All addresses from to (sections to ) programmed with values other than will report the contact ID codes corresponding to the values programmed. Values to be programmed should be selected from this table. 300 523 11 66 [2 ] [2 ] ND ND

- 4 -

REPORTING CODES: (reset code = “empty" ) All digits from to are valid. Enter (skip) = digit will not be reported except for contact I.D. programmable codes. (Select Contact I.D (all codes) - key for both central station numbers at section - address .) [2 ] [2 ] [1] [F] [2 ] [10] 09 038 ND ND ND If CONTACT I.D. format (all codes) is selected, addresses 300 to 523 (sections 11 to 66) do not have to be programmed. PG748EX ___/___ ___/___ / ___/___ ___ ___ Auto / Espload Master User code 1 User code 2 300 301 302 303 Streamline section Streamline section Data Data Description Description Address Address ARMING CODES: (closing) ___/___ ___/___ /_ ___/___ ___ __ User code 23 User code 24 User code 25 User code 26 324 325 326 327 17 11 ___/___ ___/___ / ___/___ ___ ___ User code 3 User code 4 User code 5 User code 6 304 305 306 307 ___/___ ___/___ /_ ___/___ ___ __ User code 27 User code 28 User code 29 User code 30 328 329 330 331 12 18 User code 7 User code 8 User code 9 User code 10 User code 15 User code 16 User code 17 User code 18 308 309 310 311 316 317 318 319 User code 31 User code 32 User code 33 User code 34 User code 39 User code 40 User code 41 User code 42 332 333 334 335 340 341 342 343 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 13 15 19 21 User code 11 User code 12 User code 13 User code 14 User code 19 User code 20 User code 21 User code 22 312 313 314 315 320 321 322 323 14 16 User code 35 User code 36 User code 37 User code 38 User code 43 User code 44 User code 45 User code 46 User code 47 User code 48 See next page 336 337 338 339 344 345 346 347 348 349 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ ___/___ ___/___ /_ ___/___ ___ __ ___/___ ___/___ /_ ___/___ ___ __ 20 22 23

- 5 -

REPORTING CODES: (reset code ) "empty" Streamline section Streamline section Data Data Description Description Address Address DISARMING CODES: (opening) ___/___ ___/___ /_ ___/___ ___ __ User code 21 User code 22 User code 23 User code 24 372 373 374 375 29 ___/___ ___/___ / ___/___ ___ ___ User code 1 User code 2 User code 3 User code 4 352 353 354 355 ___/___ ___/___ /_ ___/___ ___ __ User code 25 User code 26 User code 27 User code 28 376 377 378 379 24 30 User code 5 User code 6 User code 7 User code 8 User code 13 User code 14 User code 15 User code 16 356 357 358 359 364 365 366 367 User code 29 User code 30 User code 31 User code 32 User code 37 User code 38 User code 39 User code 40 380 381 382 383 388 389 390 391 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 25 27 31 33 User code 9 User code 10 User code 11 User code 12 User code 17 User code 18 User code 19 User code 20 360 361 362 363 368 369 370 371 26 28 User code 33 User code 34 User code 35 User code 36 User code 41 User code 42 User code 43 User code 44 User code 45 User code 46 User code 47 User code 48 384 385 386 387 392 393 394 395 396 397 398 399 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ /_ ___/___ ___ __ ___/___ ___/___ /_ ___/___ ___ __ 32 34 35 Espload Master See previous page 350 351 ___/___ ___/___ Streamline section Streamline section Data Data Description Description Address Address ALARM CODES ZONE 1 TO 12: ALARM CODES ZONE 13 TO 24: ___/___ ___/___ / ___/___ ___ ___ Zone 5 Zone 6 Zone 7 Zone 8 404 405 406 407 ___/___ ___/___ /_ ___/___ ___ __ Zone 13 Zone 14 N/A N/A Keypad 1 Keypad 2 412 413 414 415 37 39 Zone 9 Zone 10 Zone 11 Zone 12 408 409 410 411 N/A N/A N/A N/A 416 417 418 419 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 38 40 N/A N/A N/A N/A 420 421 422 423 ___/___ ___/___ / ___/___ ___ ___ 41 Zone 1 Zone 2 Zone 3 Zone 4 400 401 402 403 ___/___ ___/___ ___/___ ___/___ 36 23

- 6 -

REPORTING CODES: (reset code ) "empty" Streamline section Streamline section Streamline section Streamline section Data Data Data Data Description Description Description Description Address Address Address Address ZONE 1 TO 12 RESTORE CODES: ZONE 1 TO 12 SHUTDOWN CODES: ZONE 13 TO 24 RESTORE CODES: ZONE 13 TO 24 SHUTDOWN CODES: ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ Zone 5 Zone 6 Zone 7 Zone 8 Zone 5 Zone 6 Zone 7 Zone 8 428 429 430 431 452 453 454 455 ___/___ ___/___ /_ ___/___ ___ __ ___/___ ___/___ /_ ___/___ ___ __ Zone 13 Zone 14 N/A N/A Keypad 1 Keypad 2 Zone 13 Zone 14 N/A N/A Keypad 1 Keypad 2 436 437 438 439 460 461 462 463 43 49 45 51 Zone 9 Zone 10 Zone 11 Zone 12 Zone 9 Zone 10 Zone 11 Zone 12 432 433 434 435 456 457 458 459 N/A N/A N/A N/A N/A N/A N/A N/A 440 441 442 443 464 465 466 467 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 44 50 46 52 N/A N/A N/A N/A N/A N/A N/A N/A 444 445 446 447 468 469 470 471 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 47 53 Zone 1 Zone 2 Zone 3 Zone 4 Zone 1 Zone 2 Zone 3 Zone 4 424 425 426 427 448 449 450 451 ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ 42 48 Streamline section Streamline section Data Data Description Description Address Address TAMPER 1 TO 12 TROUBLE CODES: TAMPER 13 TO 24 TROUBLE CODES: ___/___ ___/___ / ___/___ ___ ___ Tamper 5 Tamper 6 Tamper 7 Tamper 8 476 477 478 479 ___/___ ___/___ /_ ___/___ ___ __ N/A N/A N/A N/A 484 485 486 487 55 57 Tamper 9 Tamper 10 Tamper 11 Tamper 12 480 481 482 483 N/A N/A N/A N/A 488 489 490 491 ___/___ ___/___ / ___/___ ___ ___ ___/___ ___/___ / ___/___ ___ ___ 56 58 N/A N/A N/A N/A 492 493 494 495 ___/___ ___/___ / ___/___ ___ ___ 59 Tamper 1 Tamper 2 Tamper 3 Tamper 4 472 473 474 475 ___/___ ___/___ ___/___ ___/___ 54

3 Digit Decimal Value Programming

Used to program addresses 044 to 061. Values entered must contain 3 digits between "000" and "255". ([10] = 0) Decimal value programming: 1) Press [ENTER] + installer code. ([ENTER] key will flash.) 2) Enter 3 digit address (044 to 061). 3) Current value will be displayed on keypad. 4) Enter 3 digit DECIMAL value. 5) Repeat from step 2 onward for next address. To exit programming mode press [CLEAR]. 044: ___/___/___ (hours) Auto arm time (between "000" and "023") 045: ___/___/___ (minutes) Auto arm time (between "000" and "059") 046: ___/___/___ (days) Auto test report every ? days (between "001" and "255") (000 = disabled) 047: ___/___/___ (hours) Auto test report (between "000" and "023") 048: ___/___/___ (minutes) Auto test report (between "000" and "059") - 7 - PG748EX

049: ___/___/___ (seconds) Exit delay (factory default 60 seconds)

050: ___/___/___ (seconds) Entry delay 1 (factory default 45 seconds) 051: ___/___/___ (seconds) Entry delay 2 (factory default 45 seconds) 052: ___/___/___ (minutes) Bell cut-off time (factory default 5 minutes) 053: ___/___/___ ( x 15 mSec.) Zone speed (factory default 600 mSec.) 054: ___/___/___ (minutes) Power failure report delay (factory default 30 minutes) (000 = disabled) 055: ___/___/___ ( x 15 minutes) "No movement" report time (factory default 8 hours) (000 = disabled) 056: ___/___/___ PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes) (factory default 5 seconds) Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 + 128 = 133) 057: ___/___/___ Intellizone delay (in seconds, minimum = 10 seconds) (factory default 48 seconds) 058: ___/___/___ Installer code lock (147 = locked, 000 = unlocked) 059: ___/___/___ (seconds) Programmable delay before alarm transmission (5 to 63 seconds) (000 = disabled) 060: ___/___/___ (seconds) Recent closing delay (000 = disabled) 061: ___/___/___ Future Use FEATURE SELECT PROGRAMMING Addresses 062-126. “ON”/”OFF” status of the key lights determines feature selection. In programming mode, enter 3 digit memory address (062 to 126). To save entries, press [ENTER]. To exit programming mode press [CLEAR]. Reset = “OFF” for addresses 062 to 126. Addresses 080 to 085 for future use. - 8 - PG748EX

- 9 -

stay arm / System A enabled enabled Bell squawk on arm/disarm Auto zone shutdown See "Reporting" table (1:1.5) Pulse USA (1:2) Pulse Europe enabled enabled enabled Auto arm on time Auto arm on no movement [5] [2] PS1/Keyswitch = regular arm [4] enabled Call back [2 ] ND [1] See "TLM" table [3] enabled PS1/keyswitch arming [6] generates only a report Silent zone/panic generates a silent alarm [11] [8] [10] [7] Pulse dialing Partitioning Tone dialing (DTMF) enabled [9] [12] 086: KEY [ ] BYP [ ] MEM [ ] TRBL OFF / ON only after alarm audible enabled audible enabled fire on zone closure 4 digit enabled enabled enabled 088: OFF / ON enabled enabled KEY no EOL Report zone restore on bell cut-off Panic 2 Panic 3 Tamper Recognition Panic 1 Automatic event buffer transmission Always report disarm Panic 2 silent Panic 1 silent (PS1) Panic 3 silent 6 digit access codes Key regular arm [10] Key stay or system A arm [11] Beep on exit delay Zones with EOL (1K ) Ω (keys & , ) [1] [3] PS1 (keys & [4] [6]) (keys & ) [7] [9] TELEPHONE LINE MONITOR TLM generates trouble only TLM disabled generates an alarm if armed silent alarm becomes audible (address , key has to be ) 086 [9] OFF KEY [2 ] ND [1] OFF OFF ON OFF ON ON OFF ON Address 086, Key [2 ] [1] ND OFF OFF ON OFF ON ON OFF ON REPORTING OPTIONS Regular reporting Reporting disabled Split reporting: Alarms System report Double reporting KEY DIALING SEQUENCE (tel. No.) TYPE [11] [12] 1,2,1,2,1,2,1,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm. 2,2,2,2,2,2,2,2, fail to comm. 1,1,1,1,1,1,1,1, fail to comm., 2,2,2,2,2,2,2,2, fail to comm. * On alarm, all reports are made to Tel. #1 until system is disarmed. (Once disarmed, system reports are made to Tel. #2) * Address 086, Key [11] [12] N/A N/A 090: Exclude power failure from trouble display [2 ] ND OFF / ON [3] [1] enabled [2] stay / System A Auto arm = regular arm KEY [6] tamper follows zone bypass definition No tamper bypass [5] [4] enabled enabled enabled [7] [8] [9] [10] [11] [12] FEATURE SELECT PROGRAMMING (continued) (On/off status of key lights determines which feature is selected.) Audible trouble warning Keypad 1 zone supervision Keypad 2 zone supervision N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PS1 software version Keypad software versions prior to 1.1 4.0 Keypad supervision must be OFF } PS1 software versions onward Keypad software versions onward 2.0 4.0 Keypad supervision must be ON } (See Wiring Diagram) PG748EX TAMPER / WIRE FAULT DEFINITIONS Exception: for 24 hour zones the tamper definition will follow the audible/silent alarm definition of the 24 hour zone. Silent zones will generate a silent alarm. Tamper supervision disabled Alarm as per individual zone definitions No alarm, trouble code reported Audible alarm. Trouble and alarm codes reported Silent alarm. Trouble and alarm codes reported Always generate trouble and alarm, audible or silent as per individual zone definitions SYSTEM ARMED ** ** Address 088, Key [10] [11] * SYSTEM DISARMED* KEY [11] [10] OFF OFF OFF ON ON OFF ON ON

KEY ACCESS PROGRAMMING

Programs features quickly, without entering addresses or section numbers. To activate “key access programming”, press [ENTER], followed by installer, master or user code 1. (Code required depends on the feature you wish to access - see below.) Press the key corresponding to the desired feature. Press [ENTER] or [CLEAR] to exit. key [8] Installer test mode (installer code only) In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long) indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones. [9] "Auto arming" time program (all 3 codes) Key [9] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes. [MEM] "Panel time" and clear "trouble 8" (all 3 codes) Key [MEM] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes. [BYP] Test report (all 3 codes) Reporting is enabled at address 086, keys [11], [12]. A value must be entered at address 512, and both telephone and account numbers must be programmed. [TRBL] Call Espload via telephone (all 3 codes) Panel identifier and PC password (addresses 004-007) and computer telephone number (addresses 008-015) must be programmed. [AWAY] Answer Espload (all 3 codes) This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem setup" section, and panel phone number programmed (works also without ADP-1). [STAY] Cancel communication attempts (master code and user 1 can only stop calls to Espload) Until next reportable event (installer code - all communications) When communicating with Espload, it is impossible to enter programming mode. PG748EX - 10 -

The system hardware will recognize the following zone conditions:

ZONE CONNECTIONS ZONE connection, without EOL (N.C. contacts) address 088, key [MEM] = "on" key [10] = "off" (reset) key [11] = "off" (reset) address 090, key [8] = "off" N.C. contacts see Figure 1 Keypad zones always use (1K OHM) EOL ZONE connection, with EOL resistor (N.C. and N.O. contacts) address 088, key [MEM] = "off" (reset) key [10] = "off" (reset) key [11] = "off" (reset) address 090, key [8] = "off" N.C. and/or N.O. contacts, see Figure 2 ZONE connection, with tamper recognition (N.C. contacts) address 088, key [MEM] = "on" key [10] = key [11] = address 090, key [8] = "off" Tamper transmits separate code, see Figure 3 ZONE connection, with EOL, with tamper recognition, and with wire fault (short circuit) recognition (N.C. contacts) address 088, key [MEM] = "off" key [10] = key [11] = address 090, key [8] = "off" Tamper/wire fault transmits separate code, see Figure 4 - 11 - PG748EX See "Tamper/wire Fault Definitions and Options" See "Tamper/wire Fault Definitions and Options" ESPRIT 748EXPRESS CONNECTION DIAGRAMS

T - 1

R - 1 TIP RING DIALER BELL RELAY PARADOX SECURITY SYSTEMS To cabinet and grounding rod For zone connections see diagrams below. Can be used as additional aux. power terminals - + - + AUX POWER 400mA max. UL/ULC 250mA max. for 24 hr. standby. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Aux power will shut down if current exceeds 1A. BELL OUTPUT UL/ULC 650mA max. will shut down if current exceeds 3A. BELL SIREN - + TRANSFO A.C. POWER 16.5VAC 40VA Smoke and heat detectors N.O. contacts * Zone 3 = Fire zone if zone definition is "24 hour". UL/ULC 12VDC / 7AH UL: K12 model T16 V4O ULC: Frost model FTC 1637 EOL 1KΩ UL/ULC: Wheelock 46T-12 Warning: Improper connection may result in damage to the system. KEYPAD 639/640 MAX 5 per system KEYPAD 616/626/633 MAX 5 per system N.C. N.O. 1K EOL Ω PS1 Keypad 1 or 2 Keypad 1 or 2 KEYSWITCH CONNECTION KEYSWITCH KYPD GRN KYPD BLK 220Ω S E C U R I T Y S Y S T E M S N.C. N.O. 1K EOL Ω * 1K EOL Ω N.C. N.C. Keypad 1 Keypad 2 PS1 software version Keypad software versions prior to 1.1 4.0 Keypad supervision must be OFF } PS1 software versions onward Keypad software versions onward 2.0 4.0 Keypad supervision must be ON } * (See Address , key ) 090 [11] [12] FIRE RESET To program PGM1 to conduct 4 second smoke detector reset when and are pressed simultaneously: [ ] [ ] CLEAR ENTER Address = (first digit) Address = 039 [ ] 040 [5] [10] BYP Address = Address = 042 [2 ] [6] 056 [10] [10] [4] ND FIRE ALARM ZONE CONNECTIONS * PGM maximum 50mA Smoke detector power supervision relay, 12VDC COM Smoke detector Smoke detector PGM Z3 AUX + 1K EOL Ω + + - - Smoke detector must be 4 wire latching - UL Falcon model 5454, ULC BRK 2412. Power supervision relay model MR3-UL. * P R DOX RMED RE DY MAX 5 per system For resistor values, refer to 639/640 installation manuals. Keyswitch can be used in parallel with keypad (or PS1). GROUND START CIRCUIT RNG WHT BLK RED YEL MR3-UL +AUX PGM WHT BLK RED MR3-UL +AUX PGM PGM OUTPUT RELAY YEL BRN COM N.C. N.O. 780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (514) 491-2313 http://www.paradox.ca Paradox Security Systems Graphic Dept PRINTED IN CANADA ESPRIT 748EXPRESS WIRING DIAGRAM BRN GRY GRN RED RJ31X CA 38A "TLM" LED: Short flash = OK Long flash = Fault Warning: Disconnect telephone line before servicing. Caution: Disconnect battery before replacing fuse. Charging and battery test LED (every 60 seconds) OFF = Disabled Constant = On Line Four pin connector can be used for quick installation of an Esprit keypad. Service Keypad + AUX - GRN YEL 748HS ESPRIT 748EXPRESS ESPRIT

Other Security System Manuals