Texas Instruments TPL5010EVM Operation & User’s Manual
Read Online
Read the Texas Instruments TPL5010EVM Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
TPL5010 Evaluation Module
This user's guide provides the setup instructions, configuration, and operation of the TPL5010 evaluation
module (EVM). Also included are the printed-circuit board (PCB) layouts, schematic, and the bill of
materials (BOM).
Contents
1
Introduction ...................................................................................................................
2
2
Setup ..........................................................................................................................
3
2.1
Jumpers and Connectors.......................................................................................... 3
2.2
Battery Requirements .............................................................................................. 5
2.3
TPL5010EVM Configuration....................................................................................... 5
3
Operation....................................................................................................................
11
3.1
Supply Current Measurement ................................................................................... 11
4
Board Layout................................................................................................................
14
5
Schematic ...................................................................................................................
16
6
Bill of Materials .............................................................................................................
17
List of Figures
1
TPL5010EVM ................................................................................................................
2
2
J1 Jumper Setting ...........................................................................................................
3
3
J1 Jumper Setting ...........................................................................................................
3
4
J2 Jumper Setting ...........................................................................................................
4
5
I_SEL Jumper Setting.......................................................................................................
4
6
R_SEL Jumper Setting......................................................................................................
4
7
Jumpers Configuration – EVM Standalone Without Microcontroller .................................................. 6
8
Jumpers Configuration – EVM With Microcontroller .................................................................... 7
9
Jumpers Configuration – EVM With LaunchPad ........................................................................ 8
10
Current Measurement Setup – TPL5010 Only ......................................................................... 11
11
Current Measurement Setup – TPL5010 During the Reading of the Resistance.................................. 12
12
Current Measurement Setup – TPL5010 With Microcontroller....................................................... 13
13
Top Layer....................................................................................................................
14
14
Bottom Layer................................................................................................................
15
15
TPL5010EVM Schematic..................................................................................................
16
List of Tables
1
Device and Package Configurations ...................................................................................... 2
2
Input/Output Connectors Description...................................................................................... 3
3
Jumpers Description.........................................................................................................
3
4
Switches and Selectors Description....................................................................................... 4
5
Test Points Description .....................................................................................................
4
6
TPL5010EVM Bill of Materials ........................................................................................... 17
LaunchPad is a trademark of Texas Instruments.
DURACELL is a registered trademark of The Gillette Company.
1
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Figure 1. TPL5010EVM
TI's TPL5010EVM evaluation module (EVM) allows a designer to configure the timer intervals of the
TPL5010 and measure its very low current consumption. Moreover, the TPL5010EVM is ready to be
connected to the LaunchPad™of the MSP430F5529 in order to test its watchdog and timer features. The
EVM has an onboard battery holder (coin battery) to supply the TPL5010 and the microcontroller, if
connected.
The EVM contains one TPL5010 (see Table 1).
Table 1. Device and Package Configurations
Device
IC
Package
U1
TPL5010DDC
SOT23-6
2
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Section 2.1 describes the jumpers and connectors on the EVM and Section 2.3 describes how to properly
connect, set up, and use the TPL5010EVM.
See Figure 1 for locations of the top layer jumpers and switches.
2.1
Jumpers and Connectors
Table 2 through Table 5 list the input/output connectors description, jumpers description, switches and
selectors description, and the test points description.
Table 2. Input/Output Connectors Description
Name
Layer
Description
J1/J3
Bottom
2 × 10 pin receptacle to plug the TPL5010EVM into the MSP430F5529 LaunchPad
J4/J2
Bottom
2 × 10 pin receptacle to plug the TPL5010EVM into the MSP430F5529 LaunchPad
RST
Bottom
2-pin receptacle to plug the TPL5010EVM into the MSP430F5529 LaunchPad
VCC
Bottom
2-pin receptacle to plug the TPL5010EVM into the MSP430F5529 LaunchPad
IO
Top
4-pin header connector to bring out RSTn, WAKE, DONE, and GND signals
IO.1
GND
Ground
IO.2
DONE
DONE signal from external microcontroller
IO.3
WAKE
WAKE signal to external microcontroller
IO.4
RSTn
RSTn signal to external microcontroller
Table 3. Jumpers Description
Name
Layer
Description
J1
Top
J1.5–J1.3 shorted, the RSTn pin of the TPL5010 is connected to the gate of Q1 MOSFET.
J1.3–J1.1 shorted, the gate of Q1 MOSFET is connected to VDD (MOSFET OFF).
Figure 2. J1 Jumper Setting
J1.6–J1.4 shorted, the WAKE pin of the TPL5010 is connected to the gate of Q2 MOSFET.
J1.4–J1.2 shorted, the gate of Q2 MOSFET is connected to VDD (MOSFET OFF).
Figure 3. J1 Jumper Setting
3
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Table 3. Jumpers Description (continued)
Name
Layer
Description
J2
Top
In short configuration, the DONE pin of the TPL5010 is connected to the S2 switch with a pull-down
resistor.
Figure 4. J2 Jumper Setting
I_SEL
Top
In open configuration allows the measurement of the current consumption of the TPL5010.
Figure 5. I_SEL Jumper Setting
R_SEL
Top
Pin1-2 in short configuration, the variable resistance is used to set the timer interval.
Pin2-3 in short configuration, the fix resistance is used to set the timer interval.
Figure 6. R_SEL Jumper Setting
Table 4. Switches and Selectors Description
Name
Layer
Description
S_ON_OFF
Bottom
In ON position turns ON the EVM, in OFF position turns OFF the EVM
S1
Top
When pushed, the SPST switch generates a DONE pulse
S2
Top
When pushed, the SPDT ON/Momentary switch generates a Manual
reset pulse
Table 5. Test Points Description
Name
Layer
Description
GND
Top
Test point of the ground, connect the GND of the power supplies
V_BATT
Top
Test point to monitor battery voltage
AUX_VDD
Top
Test point to connect external supply voltage in alternative to the coin
cell battery
4
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
In case the EVM is battery powered, the battery must meet the following requirements:
•
Battery type: CR2032 UL-certified battery
•
Voltage: 3 V
•
Minimum capacity: 220 mAh
•
Minimum discharge rate: N/A mA
NOTE:
Only insert DURACELL® 2032 Lithium battery type CR2032, or equivalent.
2.3
TPL5010EVM Configuration
The evaluation board can work standalone or plugged into the MSP430F5529 LaunchPad.
2.3.1
Setting the Time Interval Period
Set the Time interval period by tuning the variable resistance (the trimmer can generate resistances in the
range between 1 kΩ and 200 kΩ).
To tune the value of the resistance:
1. Connect a DMM between pin 1 of R_SEL and GND.
2. Turn the screw on the top of the trimmer until you reach the desired value.
3. Disconnect the DMM at the end of the operation.
Alternatively, set the DRV pulse interval with the fix resistances (R_EXT1 = 500 Ω, R_EXT2 = 0 Ω). If
required, replace the resistances with customized ones.
See Figure 1 for locations of the resistances REXT1 and REXT2.
5
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
EVM Standalone Without Microcontroller
The following settings are provided to use the EVM standalone, without a microcontroller:
•
Put the S_ON_OFF selector in the OFF position.
•
Set the mode of operation through the MODE header (see Table 3).
•
Insert a CR2032 coin cell battery in the battery holder (BT), alternatively, connect a voltage source
between the AUX_VDD and GND test points.
•
Configure jumper J1 (RSTn connected to Q1, WAKE connected to Q2) and J2 (DONE connected to
S2), as explained in Table 3.
NOTE:
Do not connect the coin cell battery and the voltage source to supply the evaluation board at
same time.
•
Put the S_ON_OFF selector in the ON position, or turn on the external voltage source if it is used
instead of the coin cell battery.
The DONE and WAKE signals can be monitored at the IO connector (pin 2 and 3, respectively).
Figure 7. Jumpers Configuration – EVM Standalone Without Microcontroller
6
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
EVM With Microcontroller
The following settings are provided to use the EVM with a microcontroller:
•
Put the S_ON_OFF selector in the OFF position.
•
Set the mode of operation through the MODE header (see Table 3).
•
Connect the microcontroller to the IO header in order to manage the I/O signal of the design under test
(DUT).
•
Supply the microcontroller, connecting its supply pin to the AUX_VDD test point and the ground to the
GND pin of the IO header.
•
Insert a CR2032 coin cell battery in the battery holder (BT), alternatively, connect a voltage source
between the AUX_VDD and GND test points.
•
Configure the jumper J1 (RSTn connected to IO, WAKE connected to IO) and J2 (DONE connected to
IO), as explained in Table 3.
NOTE:
Do not connect the coin cell battery and the voltage source to supply the evaluation board at
same time.
Do not use the switch S2 (DONE), in this configuration the DONE switch is connected to a
digital output pin of the microcontroller.
•
Put the S_ON_OFF selector in the ON position, or turn on the external voltage source if it is used
instead of the coin cell battery.
Figure 8. Jumpers Configuration – EVM With Microcontroller
7
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
EVM With LaunchPad
Load the code from this section into the MSP430F5529 of the LaunchPad. Refer to MSP430 LaunchPad
(MSP-EXP430F5529) Wiki for more details.
•
Put the S_ON_OFF selector in the OFF position.
•
Set the mode of operation through the MODE header (see Table 3).
•
Remove jumpers VCC and RST of the LaunchPad.
•
Plug the EVM into the LaunchPad (MSP430F5529), according to the following table:
TPL5010EVM
MSP430 LaunchPad
J1/J3
J1.1
VDD_µC
J1/J3
pin 1
3V3
pin 4
GND
pin 4
GND
J4/J2
pin 2
GND
J4/J2
pin 2
GND
pin 4
WAKE
pin 4
P2.0
pin 10
RSTn
pin 10
RST
pin 18
DONE
pin 18
P2.3
VCC
3V3
RST
SBW RST
•
Insert a CR2032 coin cell battery in the battery holder (BT), alternatively, connect a voltage source
between the AUX_VDD and GND test points.
•
Configure the jumper J1 (RSTn connected to Q1, WAKE connected to Q2) and J2 (DONE connected
to IO), as explained in Table 3.
NOTE:
Do not connect the coin cell battery and the voltage source to supply the evaluation board at
the same time.
Do not use the switch S2 (DONE), in this configuration, the DONE switch is connected to a
digital output pin of the microcontroller.
•
Put the S_ON_OFF selector in ON position, or turn on the external voltage source if it is used instead
of the coin cell battery.
Figure 9. Jumpers Configuration – EVM With LaunchPad
8
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Once loaded into the MSP430 of the LaunchPad, the code presented in this section performs the following
features:
•
At power on, the green LED present on the LaunchPad is turned on and turned off.
•
When the MSP430 receives a RSTn, the red LED is toggled 5 times, then the green LED is turned ON
and OFF and the MSP430 sends a DONE signal to the TPL5010.
•
When the MSP430 receives a WAKE pulse, the green LED is turned ON and OFF and the MSP430
sends a DONE signal to the TPL5010.
#include
void main(void) {
WDTCTL = WDTPW | WDTHOLD;
// Stop watchdog timer
P1DIR |= BIT0;
// Set P1.0 to output direction
P2DIR |= BIT3;
// Set P2.3 to output direction
P4DIR |= BIT7;
// Set P4.7 to output direction
P1OUT &= ~BIT0;
// Set P1.0 RED LED OFF
P2OUT &= ~BIT3;
// Set P2.3 DONE Low
P4OUT &= ~BIT7;
// Set P4.7 GREEN LED OFF
P2IES &= ~BIT0;
// P2.0 Lo/Hi edge
P2IFG &= ~BIT0;
// P2.0 IFG Cleared
P2IE
|= BIT0;
// P2.0 Interrupt Enabled
SFRRPCR |= SYSNMIIES | SYSNMI;
// Select NMI function for the RST/NMI pin,
// interrupt on falling edge
// (pull-up R on RST/NMI is already enabled after PUC)
SFRIE1 |= NMIIE;
// Set NMI pin interrupt enable
P4OUT |= BIT7;
// Set P4.7 GREEN LED ON
__delay_cycles(500000);
// Set Delay
P4OUT &= ~BIT7;
// Set P4.7 GREEN LED OFF
P2OUT |= BIT3;
// Done High
__delay_cycles(100);
// Set Delay
P2OUT &= ~BIT3;
// Done Low
__bis_SR_register(LPM4_bits + GIE);
// Enter LPM4
}
// Port 2 interrupt service routine
#pragma vector=PORT2_VECTOR
__interrupt void Port_2(void)
{
volatile unsigned int i;
P4OUT |= BIT7;
// GREEN LED ON
i = 10000;
// SW Delay
do i--;
while(i != 0);
P4OUT &= ~BIT7;
// Set P4.7 GREEN LED OFF
P2OUT |= BIT3;
// Done High
__delay_cycles(100);
// Set Delay
P2OUT &= ~BIT3;
// Done Low
P2IES &= ~BIT0;
// P2.0 Lo/Hi edge
P2IFG &= ~BIT0;
// P2.0 IFG Cleared
P2IE
|= BIT0;
// P2.0 Interrupt Enabled
9
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
// User NMI interrupt service routine
#pragma vector=UNMI_VECTOR
__interrupt void UNMI_ISR (void)
{
int n=0;
// Efficiently decode the User NMI interrupt source
switch (__even_in_range(SYSUNIV, SYSUNIV_SYSBUSIV)) {
case SYSUNIV_NMIIFG :
{
for(n=0; n<10; n++) {
volatile unsigned int i;
P1OUT ^= 0x01;
// Toggle RED led
i = 10000;
// SW Delay
do i--;
while(i != 0);
}
volatile unsigned int i;
P4OUT |= BIT7;
// GREEN LED ON
i = 10000;
// SW Delay
do i--;
while(i != 0);
P4OUT &= ~BIT7;
// Set P4.7 GREEN LED OFF
P2OUT |= BIT3;
// Done High
__delay_cycles(100);
// Set Delay;
P2OUT &= ~BIT3;
// Done Low;
}
break;
case SYSUNIV_OFIFG :
case SYSUNIV_ACCVIFG :
case SYSUNIV_BUSIFG :
default :
break;
}
}
10
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Once the EVM is powered ON, the TPL5010 starts working. Refer to the TPL5010 datasheet (SNAS651)
for further details on the timing:
•
Configure the trimmer equal to 5 kΩ to set a time interval of 1 s.
•
When an RSTn pulse is generated by the TPL5010, the red LED (D2) is turned on. The green LED
(D1) is turned on when a WAKE signal is generated by the TPL5010.
•
If the DONE switch (S2) is pushed, a DONE pulse is sent to the TPL5010. If the DONE pulse is sent
within the programmed time interval, at the next cycle the green LED (D1) is turned ON.
•
When the M_RST switch (S1) is pushed, a manual reset pulse is sent to the TPL5010. For both DONE
and M_RST pulses, the width of the pulse is proportional to the pressure time. While the M_RST
switch is pressed the red LED turns ON.
3.1
Supply Current Measurement
3.1.1
Supply Current Measurement of the TPL5010 Only
First, turn off the EVM (ON/OFF switch to OFF position), then disconnect the EVM from the LaunchPad or
microcontroller, in order to not load the digital output pins of the DUT.
•
Leave the I_SEL jumper open.
•
Do not leave digital input pins floating; Short the DONE pin (second pin of IO header) to GND (first
pin of IO header), turn OFF the Q1 and Q2 MOSFET (as explained in Table 3).
•
Connect a digital multimeter, configured as the current meter (able to measure nA), between
AUX_VDD and pin 1 of I_SEL.
•
Turn on the EVM (ON/OFF switch to ON position).
•
Read the current consumption on the DMM.
Figure 10. Current Measurement Setup – TPL5010 Only
11
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Supply Current Measurement of the TPL5010 During the Reading of the Resistance
First, turn off the EVM (ON/OFF switch to OFF position), then disconnect the EVM from the LaunchPad or
your microcontroller, in order to not load the digital output pins of the DUT.
•
Leave the I_SEL jumper open.
•
Do not leave digital input pins floating; Short the DONE pin (second pin of IO header) to GND (first
pin of IO header), turn OFF the Q1 and Q2 MOSFET (as explained in Table 3).
•
Connect a digital multimeter, configured as the current meter (able to measure nA), between
AUX_VDD and pin 1 of I_SEL.
•
Keep the MANUAL_RST switch pressed while turning ON the EVM.
•
Turn on the EVM (ON/OFF switch to ON position).
•
Read the current consumption on the DMM.
Figure 11. Current Measurement Setup – TPL5010 During the Reading of the Resistance
12
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Supply Current Measurement of the TPL5010 With Microcontroller
First, turn off the EVM (ON/OFF switch to OFF position):
•
Load the code into the microcontroller.
•
Connect the microcontroller to the EVM, refer to Section 2.3.3.
•
Install the I_SEL jumper.
•
Do not leave digital input pins floating; Ensure that the DONE signal is controlled by the
microprocessor, turn OFF the Q1 and Q2 MOSFET (as explained in Table 3).
•
Connect a digital multimeter, configured as the current meter (able to measure nA), between V_BATT
test point and AUX_VDD test point.
•
Leave the EVM OFF (ON/OFF switch to OFF position).
•
Read the current consumption on the DMM while pressing the MANUAL_RESET switch.
Figure 12. Current Measurement Setup – TPL5010 With Microcontroller
13
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Figure 13 and Figure 14 illustrate the TPL5010EVM board layouts.
Figure 13. Top Layer
14
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Figure 14. Bottom Layer
15
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
I_SEL shorted, TPL5010 supplied by battery/external
supply
I_SEL open, current consumption measured with
DMM placed between pin 1 and 2 of I_SEL.
BT
SH-J2
VDD
GND
GND
GND
1
2
3
R_SEL
R_SEL 3-2 shorted, R_EXT set by trimmer.
R_SEL 1-2 shorted R_EXT set by fix resistors
1
2
I_SEL
SH-J1
0.1µF
C1
GND
3
1
2
4
5
6
S1
PVB4 OA 300 NS LFS
Green
1
2
D1
3
1
2
-50V
Q1
AUX_VDD
AUX_VDD
GND
Super Red
1
2
D2
301
R4
1
2
3
Q2
301
R5
AUX_VDD
GND
0
REXT_2
1
2
3
4
S2
4-1437565-1
AUX_VDD
Female headers to connect the TPL5010EVM to the launchpad MSP430F5529
1
2
RST
1
2
VCC
Female headers to disconnect the PowerSupply and
RST signal of the micro present on the launchpad
4
1
2
3
IO
WAKE
DONE
GND
200k ohm
TRIM
FID2
FID1
FID3
SV601108
B
PCB Number:
PCB Rev:
LOGO
PCB
Texas Instruments
V_BATT
AUX_VDD
AUX_VDD
VDD
1
GND
2
DELAY/M_RST
3
DONE
4
WAKE
5
RST
6
U1
TPL5010DDC
499
REXT_1
100k
RP
AUX_VDD
5
4
6
7
3
1
2
S_ON_OFF
EG1257
SH-J5
SH-J4
SH-J3
AUX_VDD
Assembly Note
ZZ2
Place shunt SH-J2 on R_SEL
Assembly Note
ZZ3
Place shunt SH-J3 on J1, 3-5
Assembly Note
ZZ1
Place shunt SH-J1 on I_SEL
Assembly Note
ZZ4
Place shunt SH-J4 on J1, 4-6
Assembly Note
ZZ5
Place shunt SH-J5 on J2, 1-2
1
3
5
6
4
2
7
9
10
8
12
11
14
13
16
15
18
17
20
19
J1/J3
66953-010LF
1
3
5
6
4
2
7
9
10
8
12
11
14
13
16
15
18
17
20
19
J4/J2
66953-010LF
RSTn
WAKE
DONE
100k
RD
GND
WAKE
RSTn
DONE
AUX_VDD
GND
0.1µF
C2
RSTn
1
2
3
4
5
6
J1
AUX_VDD
GND
1
2
J2
Schematic
www.ti.com
5
Schematic
Figure 15 illustrates the TPL5010EVM schematic.
Figure 15. TPL5010EVM Schematic
16
TPL5010 Evaluation Module
SNAU173–January 2015
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
Bill of Materials
6
Bill of Materials
Table 6 lists the TPL5010EVM BOM.
Table 6. TPL5010EVM Bill of Materials
Designator
Description
Manufacturer
Part Number
Quantity
AUX_VDD
Test Point, TH, Miniature, Red
Keystone
5000
1
BT
Battery Holder, CR2032, Retainer clip, TH
Memory Protection Devices
BS-7
1
C1, C2
CAP, CERM, 0.1uF, 6.3V, +/-10%, X5R, 0402
TDK
C1005X5R0J104K
2
D1
LED, Green, SMD
OSRAM
LG L29K-G2J1-24-Z
1
D2
LED, Super Red, SMD
Lumex
SML-LX0603SRW-TR
1
GND
Test Point, TH, Miniature, Black
Keystone
5001
1
IO
Header, 100mil, 4x1, Gold, TH
Samtec
TSW-104-07-G-S
1
I_SEL
Header, TH, 100mil, 2x1, Gold plated, 230 mil above insulator
Samtec
TSW-102-07-G-S
1
J1
Header, 50mil, 3x2, Gold, TH
Sullins Connector Solutions
GRPB032VWVN-RC
1
J2
Header, 50mil, 2x1, Gold, TH
Sullins Connector Solutions
GRPB021VWVN-RC
1
J1/J3, J4/J2
Receptacle, 100mil, 10X2, TH
FCI
66953-010LF
2
Q1
MOSFET, P-CH, -50V, -0.13A, SOT-323
Diodes Inc.
BSS84W-7-F
1
Q2
MOSFET, N-CH, 50V, 0.2A, SOT-323
Diodes Inc.
BSS138W-7-F
1
R4, R5
RES, 301 ohm, 1%, 0.1W, 0603
Vishay-Dale
CRCW0603301RFKEA
2
REXT_1
RES, 499 ohm, 0.1%, 0.1W, 0603
Susumu Co Ltd
RG1608P-4990-B-T5
1
REXT_2
RES, 0 ohm, 5%, 0.1W, 0603
Vishay-Dale
CRCW06030000Z0EA
1
RD, RP
RES, 100k ohm, 5%, 0.063W, 0402
Vishay-Dale
CRCW0402100KJNED
2
RST, VCC
Connector, Receptacle, 100mil, 2x1, Gold plated, TH
TE Connectivity
5-534206-1
2
R_SEL
Header, TH, 100mil, 3x1, Gold plated, 230 mil above insulator
Samtec, Inc.
TSW-103-07-G-S
1
S1
Switch, Pushbutton, SPDT, 0.1A 14V
C&K Components
PVB4 OA 300 NS LFS
1
S2
Switch, Tactile, SPST-NO, 0.05A, 12V, SMT
TE Connectivity
4-1437565-1
1
SH-J1, SH-J2
Shunt, 100mil, Gold plated, Black
3M
969102-0000-DA
2
SH-J3, SH-J4, SH-
Mini Shunt, Closed Top, 650 V AC, -45 to 85°C, Pitch 1.27 mm,
Sullins Connector Solutions
NPB02SVAN-RC
3
J5
Height 3 mm, RoHS
S_ON_OFF
Switch, Slide, SPDT, 0.3A, SMT
E-Switch
EG1257
1
TRIM
TRIMMER, 200K, 0.25W, SMD
Bourns
3224W-1-204E
1
U1
Ultra-Low Power System Timer with Watchdog functionality and
Texas Instruments
TPL5010DDC
1
Manual Reset, DDC0006A
V_BATT
Test Point, Miniature, White, TH
Keystone
5002
1
17
SNAU173–January 2015
TPL5010 Evaluation Module
Submit Documentation Feedback
Copyright © 2015, Texas Instruments Incorporated
STANDARD TERMS AND CONDITIONS FOR EVALUATION MODULES
1.
Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, or
documentation (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance with the terms and conditions set forth herein.
Acceptance of the EVM is expressly subject to the following terms and conditions.
1.1
EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms and conditions that accompany such Software
1.2
EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.
2
Limited Warranty and Related Remedies/Disclaimers:
2.1
These terms and conditions do not apply to Software. The warranty, if any, for Software is covered in the applicable Software
License Agreement.
2.2
TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for any defects that are caused by neglect, misuse or mistreatment
by an entity other than TI, including improper installation or testing, or for any EVMs that have been altered or modified in any
way by an entity other than TI. Moreover, TI shall not be liable for any defects that result from User's design, specifications or
instructions for such EVMs. Testing and other quality control techniques are used to the extent TI deems necessary or as
mandated by government requirements. TI does not test all parameters of each EVM.
2.3
If any EVM fails to conform to the warranty set forth above, TI's sole liability shall be at its option to repair or replace such EVM,
or credit User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the
warranty period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to
repair or replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall
be warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.
3
Regulatory Notices:
3.1
United States
3.1.1
Notice applicable to EVMs not FCC-Approved:
This kit is designed to allow product developers to evaluate electronic components, circuitry, or software associated with the kit
to determine whether to incorporate such items in a finished product and software developers to write software applications for
use with the end product. This kit is not a finished product and when assembled may not be resold or otherwise marketed unless
all required FCC equipment authorizations are first obtained. Operation is subject to the condition that this product not cause
harmful interference to licensed radio stations and that this product accept harmful interference. Unless the assembled kit is
designed to operate under part 15, part 18 or part 95 of this chapter, the operator of the kit must operate under the authority of
an FCC license holder or must secure an experimental authorization under part 5 of this chapter.
3.1.2
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant:
CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC Interference Statement for Class A EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
FCC Interference Statement for Class B EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
3.2 Canada
3.2.1
For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210
Concerning EVMs Including Radio Transmitters:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Concernant les EVMs avec appareils radio:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concerning EVMs Including Detachable Antennas:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur
3.3 Japan
3.3.1
Notice for EVMs delivered in Japan: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page 日本国内に
輸入される評価用キット、ボードについては、次のところをご覧ください。
http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page
3.3.2
Notice for Users of EVMs Considered “Radio Frequency Products” in Japan: EVMs entering Japan may not be certified
by TI as conforming to Technical Regulations of Radio Law of Japan.
If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required by Radio Law of
Japan to follow the instructions below with respect to EVMs:
1.
Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,
2.
Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or
3.
Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.
SPACER
SPACER
SPACER
SPACER
SPACER
Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧くださ
い。http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
SPACER
4
EVM Use Restrictions and Warnings:
4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT
LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling
or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.
4.3 Safety-Related Warnings and Restrictions:
4.3.1
User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.
4.3.2
EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.
4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,
state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.
5.
Accuracy of Information: To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate
as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY WRITTEN DESIGN MATERIALS PROVIDED WITH THE EVM (AND THE
DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL FAULTS." TI DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY
THIRD PARTY PATENTS, COPYRIGHTS, TRADE SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.
6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS AND
CONDITIONS SHALL BE CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY
OTHER INDUSTRIAL OR INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD
PARTY, TO USE THE EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY
INVENTION, DISCOVERY OR IMPROVEMENT MADE, CONCEIVED OR ACQUIRED PRIOR TO OR AFTER DELIVERY OF
THE EVM.
7.
USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS. USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS
LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS AND CONDITIONS. THIS OBLIGATION
SHALL APPLY WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY
OTHER LEGAL THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.
8.
Limitations on Damages and Liability:
8.1 General Limitations. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,
INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS ANDCONDITIONS OR THE USE OF THE EVMS PROVIDED HEREUNDER, REGARDLESS OF WHETHER TI HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED
TO, COST OF REMOVAL OR REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES, RETESTING, OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS,
LOSS OF SAVINGS, LOSS OF USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL
BE BROUGHT AGAINST TI MORE THAN ONE YEAR AFTER THE RELATED CAUSE OF ACTION HAS OCCURRED.
8.2 Specific Limitations. IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY WARRANTY OR OTHER OBLIGATION
ARISING OUT OF OR IN CONNECTION WITH THESE TERMS AND CONDITIONS, OR ANY USE OF ANY TI EVM
PROVIDED HEREUNDER, EXCEED THE TOTAL AMOUNT PAID TO TI FOR THE PARTICULAR UNITS SOLD UNDER
THESE TERMS AND CONDITIONS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE CLAIMED. THE EXISTENCE
OF MORE THAN ONE CLAIM AGAINST THE PARTICULAR UNITS SOLD TO USER UNDER THESE TERMS AND
CONDITIONS SHALL NOT ENLARGE OR EXTEND THIS LIMIT.
9.
Return Policy. Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)
will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.
10.
Governing Law: These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,
without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated
spacer
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2015, Texas Instruments Incorporated