testo 511
de ..........................3 - 9
Instruction manual
en ........................11 - 17
Mode d’emploi
fr ........................19 - 25
Manual de instrucciones
es ........................27 - 33
Manuale di istruzioni
it ........................35 - 41
Manual de instruções
pt ........................43 - 49
Short manual testo 511
Protection cap: Park position
Absolute pressure sensor nipple
connection
Display
Control keys
Battery compartment, holding
magnets (on rear)
Basic settings
Instrument off >press and hold
2s > select with
(
),
confirm with
(
):
Unit of height above mean sea level: m, ft > Value of height above mean sea level
(Altitude) > Unit of pressure: hPa, mbar, Pa, mmH2O, mmHg, psi, inH2O, inHG, >
Auto off function: OFF, ON
Switching the instrument on
Press
.
Switching the ddisplay llight oon (for 10s)
Instrument on > press
Select display size
Instrument on > select with
:
Absolute pressure, barom (barometric pressure), Altitude (height above mean sea
level)
Select display mode
Instrument on > select with
:
Current reading > Max: Maximum values > Min: Minimum values
Switching the instrument off:
Instrument on >press and hold
2s.
de
en
fr
es
it
pt
sv
nl
??
??
Short manual testo 511
Safety and the environment
About this document
i Please read this documentation through carefully and
familiarise yourself with the product before putting it to use.
Keep this document to hand so that you can refer to it when
necessary. Hand this documentation on to any subsequent
users of the product.
i Pay particular attention to information emphasised by the
following symbols:
Important.
Avoid personal injury/damage to equipment
i Only operate the measuring instrument properly, for its
intended purpose and within the parameters specified in the
technical data. Do not use force.
i Never store the product together with solvents, acids or other
aggressive substances.
i Only carry out the maintenance and repair work that is
described in the documentation. Follow the prescribed steps
when doing so. Use only OEM spare parts from Testo.
Strong magnets. Damage to other instruments!
i Keep a safe distance from products which could be damaged
by magnetism (e.g. monitors, computers, pacemakers, credit
cards).
Protecting the environment
i Take faulty rechargeable batteries as well as spent batteries to
the collection points provided for them.
i Send the product back to Testo at the end of its useful life. We
will ensure that it is disposed of in an environmentally friendly
manner.
Safety and the enviroment
Functions and use
The testo 511 is an absolute pressure measuring instrument. It is
normally used to measure absolute pressure, e.g. for pressure
compensation in velocity measurement in ducts, laboratories and
production processes. Barometric measurements and height
measurements between two points are also possible.
Technical data
Measurement data
· Sensor:
Absolute pressure sensor
· Parameters (absolute/barometric):
Pa, hPa, mbar, mmH2O, mmHg, inHG,
inH2O, psi
· Measuring ranges:
300...1,200 hPa, 120.4...481.8 inH2O
· Resolutions:
0.1 hPa, 0.1 inH2O
· Accuracies
(Nominal temperature 22 °C, ±1 Digit):
±3 hPa, ±1.2 inH2O
· Measuring rate:
0.5 s
Further instrument data
· Protection class: IP40
· Ambient conditions:
0...50 °C, 32...122 °F
· Storage/transport conditions:
-40...70 °C, -40...158 °F
· Voltage supply:
2x 1.5 V type AAA
· Battery life:
200 h (without display light)
· Dimensions:
119x46x25 mm (inc. protection cap)
· Weight: 90 g (inc. batteries and
protection cap)
Directives, standards and tests
· EC Directive: 89/336/EEC
Warranty
· Duration: 2 years
· Warranty conditions: see guarantee
card
de
en
fr
es
it
pt
sv
nl
??
??
Specifications
At a glance
Protection cap: Park position
Absolute pressure sensor nipple
connection
Display
Control keys
Battery compartment, holding
magnets (on rear)
First steps
² Inserting batteries:
1 To open the battery compartment, push the battery cover
down.
2 Insert batteries (2x 1.5 V type AAA). Observe the polarity!
3 To close the battery compartment, push the battery cover
back on.
² Basic ssettings (configuration mode):
Adjustable functions
· Unit of height above mean sea level: m, ft
· Value of height above mean sea level (Altitude): Set flashing figure with
,
change to next figure with
.
· Unit of pressure: hPa, mbar, Pa, mmH2O, mmHg, psi, inH2O, inHG,
· Auto off function: OFF, ON (instrument switches off automatically if no key is
pressed for 10 minutes)
1 When switching the instrument on, press and hold
until
and
appear on the display (configuration mode).
-
The adjustable function is displayed. The current setting
flashes.
2 Press
(
) several times until the desired setting flashes.
Product description
) to confirm the input.
4 Repeat steps 2 and 3 for all functions.
-
The instrument changes to measuring mode.
Using the product
To measure the barometric pressure, the height above mean
sea level must be set correctly, see chapter ‘First steps’,
section ‘Basic settings (configuration mode)’.
To measure the height between two points, the height above
mean sea level at the starting point must be known and set
correctly, see chapter ‘First steps’, section ‘Basic settings
(configuration mode)’.
² Switching the instrument on:
i Press
.
-
Measuring mode is opened.
² Switching the display light on:
The instrument is switched on.
i Press
.
-
The display light goes out automatically if no key is
pressed for 10 seconds.
² Changing the parameter:
The parameter can be changed.
Adjustable parameters
· Absolute pressure
· barom (barometric pressure)
· Altitude (height above mean sea level)
i Press
several times until the desired parameter appears.
² Changing the display view:
Adjustable views
· Current reading
· Max: Maximum values since the instrument was last switched on or last reset.
· Min: Minimum values since the instrument was last switched on or last reset.
i Press
several times until the desired view appears.
de
en
fr
es
it
pt
sv
nl
??
??
Use the product
² Resetting Max/Min values:
1 Press
several times until the desired view appears.
2 Press
and hold until ---- appears.
3 Repeat steps 1 and 2 for all values that are to be reset.
² Switching the instrument off:
i Press
and hold until the display goes out.
Maintaining the product
± Changing batteries:
1 To open the battery compartment, push the battery cover
down.
2 Remove used batteries and insert new batteries
(2x 1.5 V type AAA). Observe the polarity!
3 To close the battery compartment, push the battery cover
back on.
± Cleaning the housing:
i Clean the housing with a moist cloth (soap suds) if it is dirty.
Do not use aggressive cleaning agents or solvents!
Maintaining the product
Tips and assistance 17
Tips and assistance
Questions and answers
Question
Possible causes/solutions
Hi or Lo
· Readings outside the measuring range (too high, too
low): Keep to the permitted measuring range.
· Residual capacity <10 min: Change batteries.
If we could not answer your question, please contact your dealer
or Testo Customer Service. Contact details can be found on the
guarantee card or on the Internet at: www.testo.com
Accessories and spare parts
Accessories and spare parts can be found in the product
catalogues and brochures or in the internet at: www.testo.com
de
en
fr
es
it
pt
sv
nl
??
??
Postfach 1140, 79849 Lenzkirch
Testo-Straße 1, 79853 Lenzkirch
Telefon: (07653) 681-0
Fax: (07653) 681-100
E-Mail: [email protected]
Internet: http://www.testo.com