BenchMark® MS, SS, HE

Medium-to High-Capacity Bench Scales Technical Manual PN 200154 Rev B October 9, 2020

An ISO 9001 registered company

© Rice Lake Weighing Systems. All rights reserved. Rice Lake Weighing Systems® is a registered trademark of Rice Lake Weighing Systems. All other brand or product names within this publication are trademarks or registered trademarks of their respective companies. All information contained within this publication is, to the best of our knowledge, complete and accurate at the time of publication. Rice Lake Weighing Systems reserves the right to make changes to the technology, features, specifications and design of the equipment without notice. The most current version of this publication, software, firmware and all other product updates can be found on our website: www.ricelake.com

© Rice Lake Weighing Systems ● All Rights Reserved

i Contents Technical training seminars are available through Rice Lake Weighing Systems. Course descriptions and dates can be viewed at www.ricelake.com/training or obtained by calling 715-234-9171 and asking for the training department. 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.2 Leveling the Scale. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.3 Connecting the Load Cell Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.3.1 BenchMark MS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.3.2 BenchMark SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.3.3 BenchMark HE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.4 Grounding the Scale Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.5 Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.6 Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.6.1 BenchMark MS 12'' x 12'' Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.6.2 BenchMark MS 12'' x 18'' Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.6.3 BenchMark SS 12'' x 18'' Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.6.4 BenchMark HE 12'' x 18'' Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.6.5 BenchMark MS, SS and HE, 18'' x 18'' Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2.6.6 BenchMark MS, SS and HE, 18'' x 24'' Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 2.6.7 BenchMark MS, SS and HE, 24'' x 24'' Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 3.0 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 3.3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.3.1 BenchMark MS, BenchMark SS and BenchMark HE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.4 Load Cell Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3.5 Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

BenchMark MS, SS, HE Series

ii Visit our website www.RiceLake.com Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars

© Rice Lake Weighing Systems ● All Rights Reserved

1 1.0 Introduction This manual provides an overview of technical information for the BenchMark MS, SS and HE medium-to high-capacity bench scales. Manuals and additional resources are available from the Rice Lake Weighing Systems website at www.ricelake.com Warranty information can be found on the website at www.ricelake.com/warranties 1.1 Safety Safety Signal Definitions: Indicates an imminently hazardous situation that, if not avoided, will result in death or serious injury. Includes hazards that are exposed when guards are removed. Indicates a potentially hazardous situation that, if not avoided, could result in serious injury or death. Includes hazards that are exposed when guards are removed. Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury. Indicates information about procedures that, if not observed, could result in damage to equipment or corruption to and loss of data. General Safety Do not operate or work on this equipment unless this manual has been read and all instructions are understood. Failure to follow the instructions or heed the warnings could result in injury or death. Contact any Rice Lake Weighing Systems dealer for replacement manuals. Failure to heed could result in serious injury or death. Do not allow minors (children) or inexperienced persons to operate this unit. Do not operate without all shields and guards in place. Do not jump on the scale. Do not use for purposes other then weight taking. Do not place fingers into slots or possible pinch points. Do not use any load bearing component that is worn beyond 5% of the original dimension. Do not use this product if any of the components are cracked. Do not exceed the rated load limit of the unit. Do not make alterations or modifications to the unit. Do not remove or obscure warning labels. Before opening the unit, ensure the power cord is disconnected from the outlet. Keep hands, feet and loose clothing away from moving parts. DANGER WARNING CAUTION IMPORTANT WARNING

BenchMark MS, SS, HE Series

2 Visit our website www.RiceLake.com 1.2 Overview The BenchMark MS is constructed with a mild steel frame with stainless steel top cover. The BenchMark SS and HE are constructed with a stainless steel frame and top cover. The BenchMark MS and SS contain IP66 aluminum single point load cells. The BenchMark HE contains an IP69K stainless steel single point load cell. Overload Protection The medium-to high-capacity bench scales provide overload protection with positive stops located beneath each corner of the top frame. The overload stops are set at the factory for 100% of scale capacity. Additional overload protection is provided by an overload screw beneath the load cell to help prevent shock damage. Figure 1-1. Load Cell Mount Overload Stops Figure 1-2. Overload Stops Load Cell Screw Overload Stops Top Frame Overload Stops Top Frame

© Rice Lake Weighing Systems ● All Rights Reserved

3 2.0 Installation This section provides an overview of how to install the BenchMark MS, SS and HE medium-to high-capacity bench scales. 2.1 Unpacking Immediately after unpacking, visually inspect the scale to ensure that the unit is undamaged. The shipping carton should contain the bench scale and this manual. If the bench scale was damaged in shipment, notify Rice Lake Weighing Systems and the shipper immediately. 2.2 Leveling the Scale 1. Place the scale in the desired location that is reasonably level and free of unnecessary vibrations and air currents. 2. Lift off the scale top cover and locate the level bubble. 3. Adjust the four corner feet on the scale base until the level bubble and all feet contact the support surface so the scale does not rock. 4. Lock the jam nuts on the feet when the final level is correct. 2.3 Connecting the Load Cell Cable All models come with 10' of color-coded load cell cable. Do not cut this cable. Cutting this cable voids the warranty. See the indicator manual to determine the proper load cell cable input connectors. Use the following color codes to wire the load cell cable to the indicator. 2.3.1 BenchMark MS Connect Sense and Excitation wires together if using 4-wire system without sense leads. IMPORTANT Note Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Yellow - Sense Table 2-1. 30-100 lb 12'' x 12'' Load Cell Wiring - 6 Wire Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Yellow Shield Brown - Sense Table 2-2. 50-100 lb 12'' x 18'' Load Cell Wiring - 6 Wire Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Yellow - Sense Table 2-3. 50-100 lb 18'' x 18'', 18'' x 24'', 24'' x 24'' Load Cell Wiring - 6 Wire Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Brown - Sense Table 2-4. 1000 lb 18'' x 18'', 18'' x 24'', 24'' x 24'' Load Cell Wiring - 6 Wire Note

BenchMark MS, SS, HE Series

4 Visit our website www.RiceLake.com 2.3.2 BenchMark SS Connect Sense and Excitation wires together if using 4-wire system without sense leads. 2.3.3 BenchMark HE Connect Sense and Excitation wires together if using 4-wire system without sense leads. 2.4 Grounding the Scale Base Bench scales can build up a static electricity charge during weighing operations. If powerful enough, this charge can travel through the load cell cable to the indicator. To prevent this, all bench scales should be adequately grounded so that static charges and transient electrical surges can drain directly to ground. Recommended practice is to connect the scale base to an AC ground circuit using at least #12 wire. All BenchMark scales have either a grounding screw or a hole for such a grounding screw located on the bottom of the lower frame for this purpose. 2.5 Calibration It is recommended that the scale be exercised by loading it to near capacity two or three times before calibration to ensure everything is seated. See the specific indicator manual for the proper calibration procedure. To calibrate, see the following procedure: 1. With no load on scale, place the indicator in its calibration mode and perform a zero calibration. 2. Place certified calibration weights on platform equal to 70%–100% of scale’s capacity. If several weights are used, distribute them evenly around the platform. 3. Perform a calibration. 4. Remove certified calibration weights and check the zero reading. If necessary, repeat the calibration process. See the indicator manual for the specific indicator calibration procedure. Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Yellow - Sense Table 2-5. 50 lb – 500 lb 12'' x 18'', 18'' x 18'', 18'’ x 24'', 24'' x 24'' Load Cell Wiring - 6 Wire Color Code Function Green + Excitation Black - Excitation Red + Signal White - Signal Blue + Sense Brown - Sense Table 2-6. 1000 lb 18'' x 18'', 18'’ x 24'', 24'' x 24'' Load Cell Wiring - 6 Wire Note Color Code Function Green + Excitation Black - Excitation White + Signal Red - Signal Yellow Shield Table 2-7. 50 lb – 200 lb 12'' x 18'', 18'' x 18'' Load Cell Wiring - 5 Wire Color Code Function Green + Excitation Black - Excitation White +Signal Red - Signal Yellow Shield Blue + Sense Brown - Sense Table 2-8. 250 lb – 1000 lb 18'' x 18'', 18'’ x 24'', 24'' x 24'' Load Cell Wiring - 6 Wire Note Note

© Rice Lake Weighing Systems ● All Rights Reserved

5 2.6 Replacement Parts See the following information for replacement parts details: 2.6.1 BenchMark MS 12'' x 12'' Model Figure 2-1. BenchMark MS, SS and HE, 12'' x 12'' Parts Illustration BenchMark MS 12'' x 12'' Table 2-9. BenchMark MS 12'' x 12'' Parts List 23 21 19 18 20 27 16 24 25 26 13 12 11 9 7 14 8 4 6 3 2 1 17 22 15 Item No. Part No. Description Qty. 1 35128 Foot, Bench Scale 1/4-20NC x 1-3/16 SST 4 2 14645 Nut, Jam 1/4-20NC Hex SST 4 3 32993 Frame, Bottom Bench Scale 12'' x 12'' 1 4 52342 Label, 4 x 1.25 8000T 1 6 14962 Screw, Cap 1/4-20NC x 3/4 Zinc Plated 8 7 19092 Cover, Top Bench Scale 12'' x 12'' SST 1 8 26408 Bumper, Self Adhesive 3/4 12 9 15147 Washer, Lock 1/4 Regular Zinc Plated 4 11 19089 Shim, Load Cell .060 x 1 x 1.34 SST 2 12 15410 Level, Spirit Bubble 1 13 19139 Insert, Glide Square 4 14 19132 Frame, Top Bench Scale 12'' x 12'' 1 15 16141 Cable Tie, 8'' Nylon 1 16 15418 Grommet, Rubber 1 17 14918 Screw, Set 8-32NC x 1/4 Hex 2 18 15409 Clamp, Cable No. 8 Hole Nylon 1 19 15138 Washer, Plain STD No. 8 SST 1 20 15134 Washer, Lock No. 8 Type A Zinc Plated 1 21 14858 Screw, Mach 8-32NC x 5/16 2 22 188678 Load Cell, SPT RL42018A 30 lb Scale 1 188679 Load Cell, SPT RL42018A 50 lb Scale 188678 Load Cell, SPT RL42018A 100 lb Scale 23 35327 Plug, Cap 1 x 1-1/2 ABS 4 24 14733 Bolt,1/4-20NC x 1-1/2 Hex 2 25 15145 Washer, Plain 1/4 Type A Zinc Plated 4 26 14635 Nut, Lock 1/4-20NC Hex Zinc Plated 4 27 35316 Screw, Cap 1/4-20NC x 2 Hex Zinc Plated 2 Item No. Part No. Description Qty.

BenchMark MS, SS, HE Series

6 Visit our website www.RiceLake.com 2.6.2 BenchMark MS 12'' x 18'' Model Figure 2-2. BenchMark MS 12'' x 18'' Parts Illustration BenchMark MS 12'' x 18'' Table 2-10. BenchMark MS 12'' x 18'' Parts List 23 21 15 19 18 20 26 16 14 13 4 12 11 9 7 10 3 2 1 17 22 24 25 27 8 Item No. Part No. Description Qty. 1 35128 Foot, Bench Scale 1/4-20NC x 1-3/16 SST 4 2 14645 Nut, Jam 1/4-20NC Hex SST 4 3 32992 Frame, Bottom, 12'' x 18'' 1 4 52342 Label, 4 x 1.25 8000T 1 7 19093 Cover, Top Bench Scale 12'' x 18'' SST 1 8 26408 Bumper, Self Adhesive 3/4 14 9 15147 Washer, Lock 1/4 Regular Zinc Plated 4 10 14962 Screw, Cap 1/4-20NC x 3/4 Hex Zinc Plated 8 11 19089 Shim, Load Cell .060 x 1 x 1.34 SST 2 12 15410 Level, Spirit Bubble 1 13 19139 Insert, Glide Square 4 14 19134 Frame, Top Bench Scale 12'' x 18'' 1 15 16141 Cable Tie, 8'' Nylon 1 16 15418 Grommet, Rubber 1 17 14918 Screw, Set 8-32NC x 1/4 Hex 2 18 15409 Clamp, Cable No. 8 Hole Nylon 1 19 15138 Washer, Plain STD No. 8 SST 1 20 15134 Washer, Lock No. 8 Type A Zinc Plated 1 21 14858 Screw, Mach 8-32NCx5/16 2 22 91730 Load Cell, RLSP4 50 lb Scale 1 91732 Load Cell, RLSP4 100 lb Scale 23 35327 Plug, Cap 1 x 1-1/2 ABS 4 24 14733 Bolt,1/4-20NC x 1-1/2 Hex 2 25 15145 Washer, Plain 1/4 Type A Zinc Plated 4 26 14635 Nut, Lock 1/4-20NC Hex Zinc Plated 4 27 35316 Screw, Cap 1/4-20NC x 2 Hex Zinc Plated 2 Item No. Part No. Description Qty.

© Rice Lake Weighing Systems ● All Rights Reserved

7 2.6.3 BenchMark SS 12'' x 18'' Model Figure 2-3. BenchMark SS 12'' x 18'' Parts Illustration BenchMark SS 12'' x 18'' Table 2-11. BenchMark SS 12'' x 18'' Parts List 14 20 22 16 6 10 12 24 21 15 13 3 17 11 22 9 1 8 19 4 7 2 18 23 17 5 12 Item No. Part No. Description Qty. 1 106462 Screw, Cap 1/4-20NC x 1-1/2 Hex Head SST 2 2 14634 Nut, Lock 1/4-20NC Hex SST 4 3 14645 Nut, Jam 1/4-20NC Hex SST 4 4 14862 Screw, Mach 8-32NC x 3/8 Phillips SST 2 5 14963 Screw, Cap 1/4-20NC x 3/4 Hex SST 4 6 15132 Washer, Lock No. 8 Type A SST 1 7 15138 Washer, Plain STD No. 8 SST 1 8 15148 Washer, Lock 1/4 Regular Helical Spring SST 8 9 15149 Washer, Lock 1/4 SST 4 10 15409 Clamp, Cable No. 8 Hole Nylon 1 11 15410 Level, Spirit Bubble 1 12 15418 Grommet, Rubber 1 13 186226 Frame, Bottom Bench Scale 12'' x 18'' SST 1 14 186225 Frame, Top Bench Scale 12'' x 18'' SST 1 15 186936 Top Cover, SS Bench Scale 1 16 26408 Bumper, Self Adhesive 3/4 14 17 35088 Screw, Cap 1/4-20NC x 1 Hex SST 4 18 35128 Foot, Bench Scale 1/4-20NC x 1-3/16 SST 4 19 35199 Screw, Cap 1/4-20NC x 2 Hex Head SST 2 20 43203 Screw, Set 8-32NC x 1/2 SST 1 21 52342 Label, 4.00 x 1.25 8000T 1 22 52383 Shim, Load Cell .25 x 1 x 1.34 SST 2 23 188679 Load Cell, RL42018A 50 lb Scale 1 188681 Load Cell, RL42018A 100 lb Scale 91730 Load Cell, RLPC6 50 lb Scale 91732 Load Cell, RLPC6 100 lb Scale 24 16141 Cable Tie, 8'' Nylon 1 Item No. Part No. Description Qty.

BenchMark MS, SS, HE Series

8 Visit our website www.RiceLake.com 2.6.4 BenchMark HE 12'' x 18'' Model Figure 2-4. BenchMark HE 12'' x 18'' Parts Illustration BenchMark HE 12'' x 18 Table 2-12. BenchMark HE 12'' x 18'' Stainless Steel Parts List 13 18 20 15 6 10 12 25 19 22 14 3 11 21 12 9 1 2 8 4 7 17 16 24 23 5 Item No. Part No. Description Qty. 1 106462 Screw, Cap 1/4-20NC x 1-1/2 Hex Head SST 2 2 14634 Nut, Lock 1/4-20NC Hex SST 4 3 14645 Nut, Jam 1/4-20NC Hex SST 4 4 14862 Screw, Mach 8-32NC x 3/8 Phillips SST 2 5 14963 Screw, Cap 1/4-20NC x 3/4 Hex SST 4 6 15132 Washer, Lock No. 8 Type A SST 1 7 15138 Washer, Plain STD No. 8 SST 1 8 15148 Washer, Lock 1/4 Regular Helical Spring SST 12 9 15149 Washer, Lock 1/4 SST 4 10 15409 Clamp, Cable No. 8 Hole Nylon 1 11 15410 Level, Spirit Bubble 1 12 15418 Grommet, Rubber 1 13 186225 Frame, Top Bench Scale 12'' x 18'' SST 1 14 186226 Frame, Bottom Bench Scale 12'' x 18'' SST 1 15 26408 Bumper, Self Adhesive 3/4 14 16 35128 Foot, Bench Scale 1/4-20NC x 1-3/16 SST 4 17 35199 Screw, Cap 1/4-20NC x 2 Hex Head SST 2 18 43203 Screw, Set 8-32NC x 1/2 SST 1 19 52342 Label, 4.00 x 1.25 8000T 1 20 85622 Screw, Set 8-32NC x 1/2 SST 1 21 85623 Shim, Load Cell .25 x 1 x 1.34 SST 1 22 186936 Top Cover, SS Bench Scale 1 23 85624 Screw, Cap M6 x 1 x 20 Hex SST 8 24 87029 Load Cell, RLPC6 50 lb Scale 1 87030 Load Cell, RLPC6 100 lb Scale 25 16141 Cable Tie, 8'' Nylon 1 Item No. Part No. Description Qty.

© Rice Lake Weighing Systems ● All Rights Reserved

9 2.6.5 BenchMark MS, SS and HE, 18'' x 18'' Models Figure 2-5. BenchMark MS, SS and HE, 18'' x 18'' Model Parts Illustration BenchMark MS 18'' x 18'' Table 2-13. BenchMark MS 18'' x 18'' Parts List 13 4 14 12 20 11 8 7 6 3 2 1 24 16 23 15 21 25 26 27 17 18 22 19 9 10 Item No. Part No. Description Qty. 1 19141 Foot, 1-1/2 Wide SST Pad 4 2 14649 Nut, Jam 3/8-16NC Hex Zinc Plated 4 3 49766 Frame Bottom, 18'' x 18'', MS Painted for 50 lb – 500 lb Scales 1 19108 Frame Bottom, 18" x 18", MS Painted for 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 14742 Bolt, 3/8-16NC x 1 Hex Head Zinc Plated 7 19094 Cover, Top Bench Scale 18'' x 18'' SST 1 8 26407 Bumper, Self Adhesive 16 9 15153 Washer, Lock 5/16 Regular Zinc Plated 9 10 26667 Screw, Cap 5/16-18NC x 1 Hex 4 26668 Screw, Cap, 5/16-18 NC x 3/4, Hex Zinc Plated, MS for 1000 lb Scale 4 11 49785 Washer, Plate Bench Scale Zinc Plated 11 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49765 Frame, Top, 18'' x 18'' for 50 lb – 500 lb Scales 1 19116 Frame, Top, 18" x 18" for 1000 lb Scale 15 15418 Grommet, Rubber 1 16 15045 Screw, Set 1/2-20NF x 1/2 Hex 1 17 15409 Clamp, Cable No. 8 Hole Nylon 1 18 15138 Washer, Plain STD No. 8 SST 1 19 15134 Washer, Lock No. 8 Type A Zinc Plated 1 20 49788 Screw, Cap 5/16-18NC x 1-1/4 Hex Zinc Plated 4 21 16141 Cable Tie, 8'' Nylon 1 22 14858 Screw, Mach 8-32NC x 5/16 Phillips Zinc Plated 2 23 49787 Shim Plate SST for 50 lb - 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188682 Load Cell, RL26018A 50 lb Scale 1 188684 Load Cell, RL26018A 100 lb Scale 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35316 Screw, Cap 1/4-20NC x 2 Hex Zinc Plated 4 26 15145 Washer, Plain 1/4 Type A Zinc Plated 4 27 14635 Nut, Lock 1/4-20NC Hex Zinc Plated 4 Item No. Part No. Description Qty.

BenchMark MS, SS, HE Series

10 Visit our website www.RiceLake.com BenchMark SS 18'' x 18'' Table 2-14. BenchMark SS 18'' x 18'' Parts List BenchMark HE 18'' x 18'' Table 2-15. BenchMark HE 18'' x 18'' Parts List Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49768 Frame, Bottom 18'' x 18'', SST for 50 lb – 500 lb Scales 1 19109 Frame, Bottom 18'' x 18'', SST for 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 15020 Screw, Cap, 3/8-16NC x 1 4 7 19094 Cover, Top, 18'' x 18'' SST 1 8 26407 Bumper, Self Adhesive 16 9 15154 Washer, Lock 5/16 SST 8 10 26670 Screw, Cap, 5/16-18NC x 1, Hex, SST for 50 lb – 500 lb Scales 4 26669 Screw, Cap, 5/16-18NC x 1, Hex, SST for 1000 lb Scale 11 49786 Plate, Washer, SST for 50 lb – 500 lb Scale 1 19103 Plate, Washer, SST for 1000 lb Scale 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49767 Frame, Top, 18'' x 18'', SST for 50 lb – 500 lb Scales 1 19117 Frame, Top, 18'' x 18'', SST for 1000 lb Scale 15 15418 Grommet, Rubber 1 16 15047 Screw, Set, 1/2-20NF x 1/2, Hex, SST 1 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A, SST 1 20 49789 Screw, Cap 5/16-18NC x 1-1/4 Hex, SST for 50 lb – 500 lb Scales 4 26670 Screw, Cap, 5/16-18NC x 1, Hex, SST for 1000 lb Scale 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 49787 Shim Plate SST for 50 lb – 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188682 Load Cell, RL26018A 50 lb Scale 1 188684 Load Cell, RL26018A 100 lb Scale 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock 1/4-20NC Hex SST 4 Item No. Part No. Description Qty. Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49768 Frame, Bottom 18'' x 18'', SST 4 52342 Label, 4.00 x 1.25 8000T 1 6 15020 Screw, Cap, 3/8-16NC x 1 for 50 lb – 200 lb Scales 4 101502 Screw, Cap, 3/8-16NC x 1–1/4 for 250 lb –1000 lb Scales 4 7 19094 Cover, Top, 18'' x 18'' SST 1 8 26407 Bumper, Self Adhesive 16 9 15148 Washer, Lock 1/4 SST for 50 lb – 200 lb Scales 8 15154 Washer, Lock 5/16 SST for 250 lb –1000 lb Scales 10 26670 Screw, Cap, 5/16-18NC x 1, Hex, SST for 1000 lb Scale 4 11 87090 Shim Plate SST for 50 lb – 200 lb Scales 1 87129 Shim Plate SST for 250 lb – 1000 lb Scales 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49767 Frame, Top, 18'' x 18'', SST 1 15 15418 Grommet, Rubber 1 16 87136 Screw, Set, 1/2–20NF x 1, Hex, SST for 50 lb – 200 lb Scales 1 15047 Screw, Set, 1/2-20NF x 1/2, Hex, SST for 250 lb – 1000 lb Scales 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A, SST 1 20 87092 Screw, Cap, M6 x 1 x 35 Hex for 50 lb – 200 lb Scales 8 49789 Screw, Cap, 5/16-18NC x 1 1/4, Hex, SST for 250 lb –1000 lb Scales 4 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 87091 Shim Plate SST for 50 lb – 200 lb Scales 1 49787 Shim Plate SST for 250 lb –1000 lb Scales 24 87029 Load Cell, RLPC6 50 lb Scale 1 87030 Load Cell, RLPC6 100 lb, 150 lb Scales 87031 Load Cell, RLPC6 200 lb Scale 87024 Load Cell, RLPCBC-60 250 lb, 300 lb Scales 87025 Load Cell, RLPCBC-60 500 lb Scale 87026 Load Cell, RLPCBC-60 1000 lb Scale 87022 Load Cell, RLPCBC-60 50 lb Scale 87023 Load Cell, RLPCBC-60 100 lb, 150 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock, 1/4-20NC, Hex, SST 4 Item No. Part No. Description Qty.

© Rice Lake Weighing Systems ● All Rights Reserved

11 2.6.6 BenchMark MS, SS and HE, 18'' x 24'' Models Figure 2-6. BenchMark MS, SS and HE, 18'' x 24'' Model Parts Illustration BenchMark MS 18'' x 24''' Table 2-16. BenchMark MS 18'' x 24'' Parts List 13 14 12 20 11 8 7 6 3 1 24 16 23 15 21 2 4 9 10 19 17 18 22 26 25 27 Item No. Part No. Description Qty. 1 19141 Foot,1-1/2 Wide SST Pad 4 2 14649 Nut, Jam 3/8-16NC Hex Zinc Plated 4 3 49770 Frame Bottom, 18'' x 24'', MS Painted for 50 lb – 500 lb Scales 1 19110 Frame Bottom, 18" x 24'', MS for 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 14742 Bolt, 3/8-16NC x 1 Hex Head Zinc Plated 4 7 19095 Cover, Top Bench Scale 18'' x 24'' SST 1 8 26407 Bumper, Self Adhesive 20 9 15153 Washer, Lock 5/16 Regular Zinc Plated 8 10 26667 Screw, Cap 5/16-18NC x 1 Hex, 4 26668 Screw, Cap, 5/16-18NC x 3/4, Hex Zinc Plated, MS for 1000 lb Scale 4 11 49785 Washer, Plate Bench Scale Zinc Plated 1 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49769 Frame, Top, 18'' x 24'' for 50 lb – 500 lb Scales 1 19118 Frame, Top, 18" x 24" for 1000 lb Scale 15 15418 Grommet, Rubber 1 16 15045 Screw, Set 1/2-20NF x 1/2 Hex 1 17 15409 Clamp, Cable No. 8 Hole Nylon 1 18 15138 Washer, Plain STD No. 8 SST 1 19 15134 Washer, Lock No. 8 Type A Zinc Plated 1 20 49788 Screw, Cap 5/16-18NC x 1-1/4 Hex Zinc Plated 4 21 16141 Cable Tie, 8’’ Nylon 1 22 14858 Screw, Mach 8-32NC x 5/16 Phillips Zinc Plated 2 23 49787 Shim Plate SST for 50 lb - 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188682 Load Cell, RL26018A 50 lb Scale 1 188684 Load Cell, RL26018A 100 lb Scale 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35316 Screw, Cap 1/4-20NC x 2 Hex Zinc Plated 4 26 15145 Washer, Plain 1/4 Type A Zinc Plated 4 27 14635 Nut, Lock 1/4-20NC Hex Zinc Plated 4 Item No. Part No. Description Qty.

BenchMark MS, SS, HE Series

12 Visit our website www.RiceLake.com BenchMark SS 18'' x 24'' Table 2-17. BenchMark SS 18'' x 24'' Parts List BenchMark HE 18'' x 24'' Table 2-18. BenchMark HE 18'' x 24'' Parts List Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49772 Frame Bottom, 18'' x 24'', SST for 50 lb – 500 lb Scales 1 19111 Frame Bottom, 18'' x 24'', SST 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 15020 Screw, Cap, 3/8-16NC x 1 4 7 19095 Cover, Top, 18'' x 24'' SST 1 8 26407 Bumper, Self Adhesive 20 9 15154 Washer, Lock 5/16 SST 8 10 26670 Screw, Cap, 5/16-18NC x 1, Hex, SST for 50 lb – 500 lb Scales 4 11 49786 Plate, Washer, SST for 50 lb – 500 lb Scale 1 19103 Plate, Washer, SST for 1000 lb Scale 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49769 Frame, Top, 18'' x 24'', SST for 50 lb – 500 lb Scales 1 19118 Frame, Top, 18'' x 24'', SST for 1000 lb Scale 15 15418 Grommet, Rubber 1 16 15047 Screw, Set, 1/2-20NF x 1/2, Hex, SST 1 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A 1 20 49789 Screw, Cap, 5/16-18NC x 1 1/4, Hex, SST for 50 lb – 500 lb Scales 4 26669 Screw, Cap, 5/16-18NC x 3/4, Hex, SST for 1000 lb Scale 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 49787 Shim Plate SST for 50 lb – 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188682 Load Cell, RL26018A 50 lb Scale 1 188684 Load Cell, RL26018A 100 lb Scale 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock 1/4-20NC Hex SST 4 Item No. Part No. Description Qty. Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49772 Frame Bottom, 18'' x 24'' 1 4 52342 Label, 4.00 x 1.25 8000T 1 6 101502 Screw, Cap, 3/8-16NC x 1–1/4 4 7 19095 Cover, Top, 18'' x 24'' SST 1 8 26407 Bumper, Self Adhesive 20 9 15154 Washer, Lock 5/16 SST 8 10 49789 Screw, Cap, 5/16-18NC x 1 1/4, Hex, SST 4 11 87129 Shim Plate SST 1 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49771 Frame, Top, 18'' x 24'' 1 15 15418 Grommet, Rubber 1 16 15047 Screw, Set, 1/2-20 NF x 1/2, Hex, SST 1 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A, SST 1 20 26670 Screw, Cap, 5/16-18NC x 1, Hex, SST 4 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 49787 Shim Plate SST 1 24 87022 Load Cell, RLPCBC-60 50 lb Scale 1 87023 Load Cell, RLPCBC-60 100 lb and 150 lb Scales 87024 Load Cell, RLPCBC-60 for 200 lb – 300 lb Scales 87025 Load Cell, RLPCBC-60 500 lb Scale 87026 Load Cell, RLPCBC-60 1000 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock, 1/4-20NC, Hex, SST 4 Item No. Part No. Description Qty.

© Rice Lake Weighing Systems ● All Rights Reserved

13 2.6.7 BenchMark MS, SS and HE, 24'' x 24'' Models Figure 2-7. BenchMark MS, SS and HE, 24'' x 24'' Model Parts Illustration BenchMark MS 24'' x 24'' Table 2-19. BenchMark MS 24'' x 24'' Parts List 1 14 8 7 6 3 2 21 15 23 16 24 20 12 11 25 26 27 17 18 22 19 9 10 13 4 Item No. Part No. Description Qty. 1 19141 Foot,1-1/2 Wide SST Pad 4 2 14649 Nut, Jam 3/8-16NC Hex Zinc Plated 4 3 49774 Frame, Bottom Bench Scale 24'' x 24'' MS for 100 lb - 500 lb Scales 1 19112 Frame, Bottom Bench Scale 24'' x 24'' MS for 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 14742 Bolt, 3/8-16NC x 1 Hex Head Zinc Plated 4 7 19096 Cover, Top Bench Scale 24'' x 24'' SST 1 8 26407 Bumper, Self Adhesive 20 9 15153 Washer, Lock 5/16 Regular Zinc Plated 8 10 26667 Screw, Cap 5/16-18NC x 1 Hex 4 26668 Screw, Cap, 5/16-18NC x 3/4, Hex Zinc Plated, MS for 1000 lb Scale 4 11 49785 Washer, Plate Bench Scale Zinc Plated 1 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 19096 Cover, Top Bench Scale 24'' x 24'' SST 1 15 15418 Grommet, Rubber 1 16 15045 Screw, Set 1/2-20NF x 1/2 Hex 1 17 15409 Clamp, Cable No. 8 Hole Nylon 1 18 15138 Washer, Plain STD No. 8 SST 1 19 15134 Washer, Lock No. 8 Type A Zinc Plated 1 20 49788 Screw, Cap 5/16-18NC x 1-1/4 Hex Zinc Plated 4 21 16141 Cable Tie, 8'' Nylon 1 22 14858 Screw, Mach 8-32NC x 5/16 Phillips Zinc Plated 2 23 49787 Shim Plate SST for 50 lb - 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188682 Load Cell, RL26018A 50 lb Scale 1 188684 Load Cell, RL26018A 100 lb Scale 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35316 Screw, Cap 1/4-20NC x 2 Hex Zinc Plated 4 26 15145 Washer, Plain 1/4 Type A Zinc Plated 4 27 14635 Nut, Lock 1/4-20NC Hex Zinc Plated 4 Item No. Part No. Description Qty.

BenchMark MS, SS, HE Series

14 Visit our website www.RiceLake.com BenchMark SS 24'' x 24''' Table 2-20. BenchMark SS 24'' x 24'' Parts List BenchMark HE 24'' x 24'' Table 2-21. BenchMark HE 24'' x 24'' Parts List Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49776 Frame Bottom, 24'' x 24'' SST for 100 lb – 500 lb Scales 1 19114 Frame Bottom, 24'' x 24'' SST for 1000 lb Scale 4 52342 Label, 4.00 x 1.25 8000T 1 6 15020 Screw, Cap, 3/8-16NC x 1 4 7 19096 Cover, Top, 24'' x 24'' SST 1 8 26407 Bumper, Self Adhesive 22 9 15154 Washer, Lock 5/16 SST 8 10 26670 Screw, Cap, 5/16-18 NC x 1, Hex, SST for 100 lb – 500 lb Scales 4 11 49786 Plate, Washer, SST for 100 lb – 500 lb Scale 1 19103 Plate, Washer, SST for 1000 lb Scale 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49775 Frame, Top, 24'' x 24'' SST for 100 lb – 500 Scales 1 19151 Frame, Top, 24'' x 24'' SST for 1000 lb Scale 15 15418 Grommet, Rubber 1 16 15047 Screw, Set, 1/2-20NF x 1/2, Hex, SST 1 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A, SST for 100 – 1000 lb Scales 1 20 49789 Screw, Cap, 5/16-18 NC x 1 1/4, Hex, SST for 100 lb – 500 lb Scales 4 26669 Screw, Cap, 5/16-18 NC x 3/4, Hex, SST for 1000 lb Scale 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 49787 Shim Plate SST for 100 lb – 500 lb Scales 1 22264 Shim Plate SST for 1000 lb Scale 24 188684 Load Cell, RL26018A 100 lb Scale 1 188685 Load Cell, RL26018A 150 lb Scale 188686 Load Cell, RL26018A 200 lb Scale 188687 Load Cell, RL26018A 250 lb Scale 188688 Load Cell, RL26018A 300 lb Scale 188689 Load Cell, RL26018A 500 lb Scale 91683 Load Cell, RLPWM12 1000 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock 1/4-20NC Hex SST 4 Item No. Part No. Description Qty. Item No. Part No. Description Qty. 1 19141 Foot, 3/8-16 x 78 4 2 14653 Nut, Jam 3/8-16NC Hex SST 4 3 49776 Frame Bottom, 24'' x 24'' 1 4 52342 Label, 4.00 x 1.25 8000T 1 6 101502 Screw, Cap, 3/18NC x 1-1/4 Hex 4 7 19096 Cover, Top, 24'' x 24'' 1 8 26407 Bumper, Self Adhesive 22 9 15154 Washer, Lock 5/16 SST 8 10 26670 Screw, Cap, 5/16-18 NC x 1, Hex, SST 4 11 87129 Shim Plate SST 1 12 15410 Level, Spirit Bubble 1 13 19140 Square Plug Black 8 14 49775 Frame, Top, 24'' x 24'' 1 15 15418 Grommet, Rubber 1 16 15047 Screw, Set, 1/2-20 NF x 1/2, Hex, SST 1 17 15409 Clamp, Cable, No. 8 Hole 1 18 15138 Washer, Plain STD #8 SST 1 19 15132 Washer, Lock No. 8 Type A, SST 1 20 49789 Screw, Cap, 5/16-18 NC x 1 1/4, Hex, SST for 100 lb – 500 lb Scales 4 21 16141 Cable Tie, 8'' Nylon 1 22 14862 Screw, Mach, 8-32NC x 3/8, SST 2 23 49787 Shim Plate SST 1 24 87023 Load Cell, RLPCBC-60 100 lb and 150 lb Scales 1 87024 Load Cell, RLPCBC-60 200 lb, 250 lb and 300 lb Scales 87025 Load Cell, RLPCBC-60 500 lb Scale 87026 Load Cell, RLPCBC-60 1000 lb Scale 25 35199 Screw, Cap, 1/4-20NC x 2, Hex, SST 4 26 15149 Washer, Plain, 1/4 Type A, SST 4 27 14634 Nut, Lock, 1/4-20NC, Hex, SST 4 Item No. Part No. Description Qty.

© Rice Lake Weighing Systems ● All Rights Reserved

15 3.0 Appendix This section provides additional information about the BenchMark MS, SS and HE medium-to high-capacity bench scales. 3.1 Options Optional ball transfer, roller conveyor tops and custom height columns for attaching indicators to the scale are available. Consult the factory for available options. 3.2 Troubleshooting For troubleshooting details, see the following information: Issue Cause Solution No display on indicator Power disconnected Connect power Cable cut or disconnected Repair cable Signal leads incorrectly wired at indicator Connect according to the manual Indicator display remains at zero Incorrect load cell cable connections Faulty indicator Service indicator Erratic weight displays on indicator Vibration near the scale Remove the source of the vibration or adjust digital filtering of indicator to minimize erratic display Scale not level Level the scale Water damage to the load cell or cable Replace the load cell Faulty indicator Service the indicator Loose load cell screws Tighten to correct torque Faulty load cell Test and replace if necessary Consistently low weight Indicator not properly adjusted to zero Zero indicator correctly Scale cover binding Obtain adequate clearance Overload stops set too high Reset the stops correctly Indicator not calibrated for scale Calibrate the scale Faulty load cell Test and replace if necessary Table 3-1. Benchmark Troubleshooting Table

BenchMark MS, SS, HE Series

16 Visit our website www.RiceLake.com 3.3 Dimensions For BenchMark MS, SS and HE bench scale dimensions see the following information: Figure 3-1. BenchMark Dimensions 3.3.1 BenchMark MS, BenchMark SS and BenchMark HE See Figure 3-1 for Table 3-2 dimension references. For load cell approvals, see Section 4.0 on page 19. Capacity Product Dimensions (L x W x H) L1 x W1 30 lb (15 kg) 12'' x 12'' x 4.12'' (305 mm x 457 mm x 105 mm) 12.50'' x 12.50'' (318 mm x 318 mm) 50 lb (25 kg) 100 lb (50 kg) 50 lb (25 kg) 12'' x 18'' x 3.62'' (305 mm x 457 mm x 92 mm) 12.50'' x 18.50'' (318 mm x 470 mm) 100 lb (50 kg) 50 lb (25 kg) 12'' x 18'' x 4'' (305 mm x 457 mm x 102 mm) 12.50'' x 18.50'' (318 mm x 470 mm) 100 lb (50 kg) 50 lb (25 kg) 12'' x 18'' x 4.12'' (305 mm x 457 mm x 105 mm) 12.50'' x 18.50'' (318 mm x 470 mm) 100 lb (50 kg) 50 lb (25 kg) 18'' x 18'' x 5.25'' (457 mm x 457 mm x 133 mm) 18.75'' x 18.75'' (476 mm x 476 mm) 100 lb (50 kg) 150 lb (75 kg) 200 lb (100 kg) 250 lb (125 kg) 300 lb (150 kg) 500 lb (250 kg) 1000 lb (500 kg) 50 lb (25 kg) 18'' x 24'' x 5.25'' (457 mm x 610 mm x 133 mm) 24.75'' x 18.75'' (629 mm x 476 mm) 100 lb (50 kg) 150 lb (75 kg) 200 lb (100 kg) 250 lb (125 kg) 300 lb (150 kg) 500 lb (250 kg) 1000 lb (500 kg) 100 lb (50 kg) 24'' x 24'' x 5.25'' (610 mm x 610 mm x 133 mm) 24.75'' x 24.75'' (629 mm x 629 mm) 150 lb (75 kg) 200 lb (100 kg) 250 lb (125 kg) 300 lb (150 kg) 500 lb (250 kg) 1000 lb (500 kg) Table 3-2. Dimensions and Capacities H W1 L1 L W

© Rice Lake Weighing Systems ● All Rights Reserved

17 3.4 Load Cell Replacement See the following procedure to replace load cells: 1. Unplug AC power from indicator and disconnect load cell cable from indicator. 2. Lift off the top cover. 3. Remove two load cell screws. 4. Lift off top spider. 5. Remove the spacer plate. Figure 3-2. 12'' x 12'' Load Cell Mount 6. Loosen the four overload stop screws and turn each screw in one turn to provide ample clearance for the new load cell. Turn scale over and back off overload protection screw one complete turn to provide clearance. 7. Unscrew and remove lower load cell screws. Depending on model of scale, there will be either two or four lower load cell screws. 8. Remove bottom shim beneath load cell and set it aside. 9. Remove load cell and cable from scale. 10. Thread cable of replacement load cell through rubber grommet. 11. Position bottom shim directly beneath load cell and screw in lower load cell screws. Torque to 80 in-lbs for 12'' x 12'' and 12'' x 18'' scales, to 120 in-lb for 18'' x 18'', 18'' x 24'', and 24'' x 24'' scales. 12. Turn scale right side up. Position spacer plate on load cell, then place top spider into position. 13. Screw in four upper load cell screws. Torque to 80 in-lbs for 12'' x 12'' and 12'' x 18'' scales, to 120 in-lb for 18'' x 18'', 18'' x 24'', and 24'' x 24'' scales. 14. Connect load cell cable to indicator. 15. Recalibrate scale (Section 2.5 on page 4). 16. Adjust overload protection screw on bottom of scale by loading scale to 125% capacity. Place this weight on top cover, centered on platform. Use a hex wrench to screw in overload protection screw until it touches the load cell, then back off 1/6 turn. Recheck calibration. 17. To reset corner overload stop screws, load top spider over one corner with approximately 30% of scale capacity. Adjust screw under that corner to just touch top frame. Place a drop of a non-permanent, high-strength locking compound such as Loctite® on the thread. Back screw off slightly so it is not touching. Load Cell Screw Scale Top Load Plate / Spider Load Cell Screw Top Sub-Assembly

BenchMark MS, SS, HE Series

18 Visit our website www.RiceLake.com 3.5 Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials and workmanship for two years for the BenchMark MS and BenchMark SS and three years for the BenchMark HE. RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized by RLWS. RLWS warrants the equipment against faulty workmanship and defective materials. If any equipment fails to conform to these warranties, RLWS will, at its option, repair or replace such goods returned within the warranty period subject to the following conditions: • Upon discovery by Buyer of such nonconformity, RLWS will be given prompt written notice with a detailed explanation of the alleged deficiencies. • Individual electronic components returned to RLWS for warranty purposes must be packaged to prevent electrostatic discharge (ESD) damage in shipment. Packaging requirements are listed in a publication, “Protecting Your Components From Static Damage in Shipment,” available from RLWS Equipment Return Department. • Examination of such equipment by RLWS confirms that the nonconformity actually exists, and was not caused by accident, misuse, neglect, alteration, improper installation, improper repair or improper testing; RLWS shall be the sole judge of all alleged nonconformities. • Such equipment has not been modified, altered, or changed by any person other than RLWS or its duly authorized repair agents. • RLWS will have a reasonable time to repair or replace the defective equipment. Buyer is responsible for shipping charges both ways. • In no event will RLWS be responsible for travel time or on-location repairs, including assembly or disassembly of equipment, nor will RLWS be liable for the cost of any repairs made by others. These warranties exclude all other warranties, expressed or implied, including without limitation warranties of merchantability or fitness for a particular purpose. Neither RLWS nor distributor will, in any event, be liable for incidental or consequential damages. RLWS and buyer agree that RLWS’s sole and exclusive liability hereunder is limited to repair or replacement of such goods. In accepting this warranty, the buyer waives any and all other claims to warranty. Should the seller be other than RLWS, the buyer agrees to look only to the seller for warranty claims. No terms, conditions, understanding, or agreements purporting to modify the terms of this warranty shall have any legal effect unless made in writing and signed by a corporate officer of RLWS and the Buyer.

© Rice Lake Weighing Systems ● All Rights Reserved

19 4.0 Specifications Load Cell BenchMark MS IP66 aluminum, environmentally sealed BenchMark SS IP66 aluminum, environmentally sealed BenchMark HE IP69K stainless steel, hermetically sealed Available Sizes Benchmark MS 12'' x 12'', 12'' x 18'', 18'' x 18'', 18'' x 24'', 24'' x 24'' BenchMark SS 12'' x 18'', 18'' x 18'', 18'' x 24'', 24'' x 24'' BenchMark HE 12'' x 18'', 18'' x 18'', 18'' x 24'', 24'' x 24'' Rated Output 0.91 mV/V Maximum Overload 150–200% depending on capacity Overload Protection 5 point, independently adjusted Cable Length 10' (3 m) – 6 wire shielded Output Impedance 350  Compensated Temperature Range 14° F – 122° F (-10° C – 50° C) Safe Temperature Range -22° F – 158° F (-30° C – 70° C) Certifications and Approvals NTEP CoC 95-072 Accuracy Class III; 5000 d Measurement Canada AM-5082, Class III 5000 d The following load cells are cFMus approved: BenchMark MS 12'' x 12'' 30 lb – 100 lb 18'' x 18'' 50 lb – 500 lb 18'' x 24'' 50 lb – 500 lb 24'' x 24'' 50 lb – 500 lb BenchMark SS 12'' x 18'' 50 lb – 100 lb 18'' x 18'' 50 lb – 500 lb 18'' x 24'' 100 lb – 500 lb 24'' x 24'' 100 lb – 500 lb The following load cells are FM approved: BenchMark MS 12'' x 18'' 50 lb – 100 lb 18'' x 18'' 1000 lb 18'' x 24'' 1000 lb 24'' x 24'' 1000 lb BenchMark SS 18'' x 18'' 1000 lb 18'' x 24'' 1000 lb 24'' x 24'' 1000 lb BenchMark HE 12'' x 18'' 50 lb – 1000 lb 18'' x 18'' 50 lb – 1000 lb 18'' x 24'' 50 lb – 1000 lb 24'' x 24'' 50 lb – 1000 lb

230 W. Coleman St. • Rice Lake, WI 54868 • USA

U.S. 800-472-6703 • Canada/Mexico 800-321-6703 • International 715-234-9171 • Europe +31 (0)26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company. © Rice Lake Weighing Systems Specifications subject to change without notice. www.ricelake.com PN 200154 Rev B October 9, 2020