The CELaligner® is a dual function tool for alignment of panel antennas. It can be used for
adjusting both the elevation (downtilt) and the azimuth. The CELaligner® is supplied in a handy
carrier bag, to wear round the shoulder, when climbing an antenna mast or tower.
Antenna Tilt Adjustment Tool
CELaligner®
April 7, 2006 V800 Vers 1.1
Radio Frequency Systems
Please visit us on the internet at http://www.rfsworld.com
T h e C l e a r C h o i c e i n W i r e l e s s T M
Easy to Fasten
The CELaligner® is equipped with an elastic belt for
easy fastening on the antenna, and for hands free
operation, thus assuring optimized security when
working up in the mast with panel antennas and
CELaligner®. (Fig. 1)
Elevation
The built-in level vial helps you to precesily set the
elevation of the antenna. (Fig. 2)
1. Adjust to required elevation angle on the
graduated arc.
2. Place the CELaligner® on the rear side of the
antenna.
3. Tilt the antenna until the vial is in level.
Azimuth
Having found a reference point on a map and hereafter
determinated the offset from the reference point to the
decided direction, you adjust the angle on the
fraduated arc located on the CELaligner®.(Fig. 3)
When having fastened the CELaligner® to the panel
antenna, it is time for adjusting the direction of the
antenna by using the tracking sight. (Fig. 4)
Adjustment Guideline
1.
Find reference point on map in horizon (e.g. church tower).
2.
Determine offset (degrees) from reference point to required beam direction.
3.
Adjust the angle on graduated arc on the CELaligner® (offset).
4.
Mount the CELaligner® on the panel antenna. Adjust the antenna by using the tracking sight.
Antenna Tilt Adjustment Tool
CELaligner®
April 7, 2006 V800 Vers 1.1
Radio Frequency Systems
Please visit us on the internet at http://www.rfsworld.com
T h e C l e a r C h o i c e i n W i r e l e s s T M
Vertical Calibration
Step 1: Press the aligning rod (A) against a perfectly vertical wall
Step 2: Follow normal aligning procedure until the bubble of the spirit level is centered.
Step 3: The scale should now be pointing at zero degrees.
Horizontal Calibration
Step 4: Place the aligning rod (A) against a perfectly horizontal plane.
Step 5: Follow normal aligning procedure until the bubble of the spirit level (B) is centred.
Step 6: The scale (C) should now be pointing at 90 degrees.
Step 7: If the statements in step 3 and 6 are not true then the CELaligner® is out of order and should not
be used.
The CELaligner® should be calibrated once every 12 months.
A
B
C
A
B
C