Resol TLR2 Manual
Read Online
Read the Resol TLR2 Manual online using the built-in PDF viewer.
Text of the manual
Thanks for buying a RESOL product.
Read this manual carefully to get the best perfomance from this unit.
TLR2 store charge controller
| 2
© RESOL 06277 TLR2.mon.en.indd
Contents
Safety instructions ............................................................. 2
Technical data and functional survey .............................. 3
1.
Sensor types ........................................................... 4
2.
Installation .............................................................. 5
2.1
Mounting ................................................................ 5
2.2
Electrical connection ............................................. 5
3.
Operation and function ......................................... 6
3.1
Setting pushbutton ................................................ 6
3.2
Control parameter and indication channels ....... 6
3.3
Indication channel SU ........................................... 6
3.4
Indication channel SL ............................................ 6
3.5
Indication channel HO .......................................... 6
3.6
Indication channel PG ........................................... 6
3.7
Indication channel VN .......................................... 6
3.8
Indication channel TO .......................................... 7
3.9
Indication channel TF ............................................ 7
3.10
Indication channel MM .......................................... 7
3.11
Status-LED blinking codes .................................... 7
4.
Initiation ................................................................. 7
5.
Tips for debugging ................................................. 8
Security advice
Please pay attention to the following security advice in order
to avoid danger and damage to people and property.
Instructions
Attention should be paid
- to the statutory provisions for prevention of industrial
accidents,
- to the statutory provisions for environmental protection,
- to the Health and Safety at Work Act 1974
- to Part P of the Building Regulations 2005
- to BS7671 Requirements for electrical installations and
relevant safety regulations of DIN, EN, DVGW, TRGI, TRF
and VDE.
This instruction is exclusively addressed to authorised
skilled personnel.
- Only qualified electricians should carry out electrical
works.
- Initial installation should be effected by named qualified
personnel
Declaration of conformity
We, RESOL Elektronische Regelungen GmbH, D-45527
Hattingen, declare under our sole responsibility that our
product TLR2 complies with the following standards:
EN 55 014-1
EN 60 730-1
According to the regulations of the above directives, the
product is labelled with
:
89/336/EWG
73/ 23/EWG
Hattingen, 07.07.2006
RESOL Elektronische Regelungen GmbH,
ppa. Gerald Neuse
TLR2 store charge controller
3 |
© RESOL 06277 TLR2.mon.en.indd
TRL2
Electronic store charge controller, with LCD combidis-
play for concurrent display of the upper and the lower
store temperature for optimised charge with one ener-
gy source (e.g. central heating boiler). The temperature
is collected by temperature sensors in the upper and
lower part of the store. When the switch-on tempe-
rature of the upper sensor is under-run, the store is
charged until the switch-off temperature is reached in
the upper sensor. The controller is menu-driven.
Two sensors from our product range (type Pt1000) are
needed, (please order additionally) e.g. 2 x FRP150.
Technical data
Housing: plastic, PC-ABS and PMMA
Protection type: IP 20 / DIN 40050
Ambient temperature: 0 ... 40 °C
Size: 172 x 110 x 46 mm
Power supply:
220 … 240 V~
breaking capacity:
1 relay output (alternating relay)
Schaltstrom 4(1) A
Ambient temperature:
-20 °C ... bis +40 °C
store nominal temperature:
20 ... 90°C
Display: LCD, multi functioning combi display with
pictogramms, two 2-digit description field and two
4-digit 7-segment-displays as well a 2-coloured
LED.
Installation: wall mounting, control panel-Instal-
lation possible
Operation: vie 3 pushbuttons in the front of the
housing
Inputs: 2 temperature sensors Pt1000
Degree of pollution: 2
Rating surge voltage: 2,5 kV
Temp. for ball pressure check: 75 °C
The store charge controller RESOL TLR2 optimises the
charging of a warm water- heat accumulator via one energy
source, e.g. a central heating boiler. The store temprature
is collected by sensors S1 and S2 in the upper resp. lower
part of the store. The charging cycle starts as soon as the
upper sensor S1 collects a temperature thatis lower than
the preadjusted switch-on temperature. The charging occurs
until the temperature of S2 (in the lower part of the store)
exceeds the preadjusted switch-off temperature.
Benefits:
Functioning
- The store is heated up completely (avoidance of danger
caused by Legionellen).
- The heating up of the store takes place in big intervals ;
therefore longer burner running time
The controller TLR2 needs two sensors from our product
range.
TLR2 store charge controller
| 4
© RESOL 06277 TLR2.mon.en.indd
For the controller RESOL TLR2 precision temperature
sensors in Pt1000-version (FKP and FRP) are used.
FK: 1,5 m long weather- and temperatureproof siliconcable
for temperatures from -50 °C ... +180 °C, preferably for the
collector.
FR: 2,5 m long PVC-cable for temperatures from -
5 °C ... +80 °C, preferably for the store.
The corresponding local VDE-regualtions must be obeyed.
The sensor cables carry low voltage and musn’t be installed
in one cable channel with cable that carry more than 50V.
The sensor cables can be elongated up to 100 m, whereas
the cross-section of the extensioncable must have 1,5 mm2
(resp. 0,75 mm2 at cable lengths up 50 m). With long cables
and when using cable channels cables with twisted leads
should be used. For immersion sensors immersion sleeves
must be used.
1. Sensor types
immersion sensor: available in different lengths (immer-
sion depth)
FK...60: 60 mm immersion depth, brass sleeve, chromium-
plated
FK...150: 150 mm immersion depth, brass sleeve, chromium-
plated
Important: push the sensor completely into the sleeve and
tighten the fitting.
Pipe sensor: for any pipe diameter, complete with clam-
ping band
FK...21 or FR...21
Der Sensor must have good thermal contact to the pipe.
Therefore clean the contact surface carefully and apply heat
conduction paste between sensor and pipe. For protection
against outside temperature influences wind the sensor cable
around the pipe once and insulate well.
Contact sensor: for application to plane surfaces
FK...9 or FR...9
Pay attention to good thermal contact. Use heat conduction
paste and insulate against outside temperature influences.
FK... : collector sensor
FR... : reference sensor (store sensor)
TLR2 store charge controller
5 |
© RESOL 06277 TLR2.mon.en.indd
T4A
PRG
1
2
S1
Temp. Sensor
Pt1000
L
N
L’
N
20
19
18
17
13
12
15 16
M
R
A
14
3
4
S2
TLR2
2 (1) A (220 ... 240)V~
top cover
key panel
base
clamp
blind
grommet with strain relief
operation-controll lamp
combi-LCD
2.1 mounting
The mounting has to be made only in dry interiors. Keep in
mind that the controller musn’t be installed at a place where
it can be influenced by strong electromagnetic fields. Accor-
ding to the current regulations for installation the controller
must be equipped with an additional set-up which allows the
separation from the power line by an isolating distance of at
least 3 mm. Attend to separated laying when installing the
mains connection cable and the sensor cable.
1. Unscrew the cross-head screw of the blind and pull the
blind down from the housing.
2. Mark the upper attachment point on the subsurface and
premount the attached dowel with the matching screw.
3. Replace the housing at the upper attachment point, mark
the lower attchment point at the subsurface (hole centre
distance 130 mm), afterwards fix the lower dowel.
4. Replace housing at the upper point and fix it with a at-
tachment screw.
2. Installation
Attention!
2.2 Electrical connection
The power supply of the controller must be effected by
an external power switch (last workstep!) and the power
supply must be 220 ... 240 Volt (50...60 Hz). Flexible cables
must be fixed to the housing with the attached strain relief
clamp and the matching screws.
The controller is equipped with 1 relay (change-over con-
tact), to which the matching consumer load is attached (e.g.
store charge pump):
• Pump-relay R1
14 = home contact R
15 = medium contact M
16 = make contact A
The temperature sensors (S1 and S2) are connected to
the following clamps with any polarity:
1 / 2 = sensor for the upper store temperature
3 / 4 = sensor for the lower store temperature
The mains connection is at the clamps:
19 = neutral wire N
20 = conductor L
12 = earthing clip
pipe clamp
fuse
sensor clamps
consumer-clamps
(pump)
bridge
Indication:
The medium contact M (15) and the conductor L’ (18) are
bridged in delivery condition.
After removing the bridge the change-over contact (RMA)
becomes a potential-free relay.
Ensure separation from power
supply before opening the hou-
sing
TLR2 store charge controller
| 6
© RESOL 06277 TLR2.mon.en.indd
1
2
3
T4A
PRG
1
2
S1
Temp. Sensor
Pt1000
L
N
L’
N
20
19
18
17
13
12
15 16
M
R
A
14
3
4
S2
TLR2
2 (1) A (220 ... 240)V~
R1
S2
S1
3 Operation and functions
3.1 setting switch
The controller is operated by 3 push-buttons below the dis-
play. The forward-button (1) serves the function of scrolling
forward through the display menu or raising the set values.
The backwards button(2) is serves the contrary.
After the display channels there are the setting channels. In
order to get to these channels, the forward button has to
be pushed for 2 sec. after channel HO. If the display shows a
set value, SEt is shown in the display. In this case the setting
mode can be changed if the set-button (3) is pushed.
chose channel with button 1 and 2
press button 3 quickly, display „SEt“ flashes
set the value with buttons 1 and 2
press button 3 quickly, display permanently shows„SEt“
again, the setted value is memorised
backwards
forward
Set
(selection / setting mode)
3.2 controlparameter and display channels
• SU Upper Store temperature
display channel of the current upper store temperature
• SL Lower Store temperature
display channel of the current lower store temperature
• HO Hours of Operation
display channel of the operation hours
• TO Temperature On
setting channel switch-on temperature
• TF Temperature ofF
setting channel switch-off temperature
• MM Manual Mode
setting channel manuel mode
• PG ProGramm
display channel programme number
• VN Version Number
Anzeigekanal Versionsnummer
3.3 display channel SU
SU shown the current upper store tempertaure
3.4 display channel SL
SL shows the current lower store temperature
3.5 display channel HO
HO shows the operation hours if the controller
3.6 display channel PG
PG shows the programme number of the controller
3.7 display channel VN
VN shows the version-number of the controller software
2.3 example of use
TLR2 store charge controller
7 |
© RESOL 06277 TLR2.mon.en.indd
4. Initiation
First switch on the power supply. The controller initialises
while the operation control lamp flashes green and red.
After finishing the initialisation the controller is in automatic
operation mode which ensures by the factory settings an
optimum degree of efficiency for most systems.
In case that the individual systems require an adaptation to
the controller parameters they can be changed with the
corresponding set values (see 3.2).
3. 8 setting channel TO
When the upper store temperature SU falls below the
setted value TO, the controller switches on the relay/pump
and loads the store. The display shows
and the status-
LED glows green.
TO:switch-on temperature
setting range 20,0 ... 95,0 °C
in 0,5 steps
factory setting 40,0 °C
3.9 setting channel TF
While the controller charges the store the lower store SL
rises. When this temperature exceeds the value setted in
TF, the relay/pump is switched-off and the loading of the
store stops. The symbol
disappears from the display and
the status-LED glows red.
In order to avoid wrong settings the values TO and TF are
blocked against each other.
TF: switch-off temperature
setting range 20,0 ... 95,0 °C
in 0,5 steps
factory setting 45,0 °C
3.10 setting channel MM
Here you can chose between automatic and manual ope-
ration. In the manual operation mode the charging of the
store can be started and stopped manually.
For permanently deactivated store charge chose „0“, for
permanently activated store charging chose „1“. If the con-
troller is to charge the store automatically chose „2“.
manual ope-
ration
0 = on
1 = off
2= Auto
MM: switch-off temperature
setting range 0, 1, 2
factory setting 2 (Auto)
constantly green:
relay/pump switched on
constantly red:
relay/pump switched off
flashing green/red:
initialisation
defective sensor
manual operation
3.11 status-LED blinking codes
TLR2 store charge controller
| 8
© RESOL 06277 TLR2.mon.en.indd
T4A
PRG
1
2
S1
Temp. Sensor
Pt1000
L
N
L’
N
20
19
18
17
13
12
15 16
M
R
A
14
3
4
S2
TLR2
2 (1) A (220 ... 240)V~
Attention!
Ensure separation from power
supply before opening the hou-
sing
5. tips for fault location
PLease check the following if the controller does
not work properly:
1. power supply
In case that the operation control lamp is lapsed please
check the power supply of the controller.
The controller is protected with 1 fuse T4A. You can
exchange it after removing the blind (spare fuse is in the
accessory bag).
2. defecctive sensor
In case that a system fault is caused by a defective sensor the
operation control lamp flashes red/green and the symbol
is shown in the display. A corresponding error code is shown
in the display for the sensors in question.
short-circuit:
a short-circuit of the sensorcable with
declaration of the affected sensor is
shown in the display with the error
code -888.8.
wire breakage:
Interruption of the sensor cable with
declaration if the affected sensor is
shown in the display with the error
code 888.8.
Pinched off Pt1000-temperature sensors can be checked
with a resitance measuring device and have the resitance
values shown in the table on the left.
resistance values of
the Pt1000-sensors
fuse T4A
Your specialist dealer:
Note
The design and the specification can be changed without any prior notice.
The pictures can slightly differ from the production model.