ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN

1 2 PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION. DO NOT CONNECT THE LUMINAIRE LIVE Bilux Inground Ø90mm Hole diameter 145mm Hole depth Ensure there is a drain under the substrate when installing the tting into paving or cement Drainage detail spec by Civil Engineer. 2. Create a cavity for tting in the ground/paving at the required position. NB: GRAVEL FOR DRAINAGE: Lay at least 50mm of 13mm or 19mm Chip Stones beneath the well of the cavity and check drainage efciency. DRAIN GROUND PAVING/ CEMENT 13/19mm Chip Stones 3 - 13 MAIN REEF SERVICE ROAD, CORNER SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA, JOHANNESBURG. SOUTH AFRICA. TEL : +27 11 474 0171 www.regentlight.co.za REGENT LIGHTING A DIVISION OF WAHL INDUSTRIES. September 2021 98 53 Ÿ Be sure the electricity to the system you are working on is isolated. Ÿ If the main supply power (live) is on, it will cause damage to the luminaire. Ÿ Ambient temperature: Ta 36ºC Ÿ IP rating according to IEC 60598-1: -Gear compartment: IP65 Ÿ Mounting: In-ground installation -Optical compartment: IP65 Ÿ Control gear weight: 220V - 240 V AC 50 Hertz 1 2 1. Selected the required position for the luminaire. Create cavity in for plastic sleeve. DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE. Bilux Inground Remote Electronic Control Device WARNING ELECTRIC SHOCK HAZARD This equipment is to be serviced by trained personnel only. 50 Bilux Inground Save These Instructions for Future Reference Regent Lighting reserves the right to change specifications modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING WARNING: TO AVOID FIRE, SHOCK OR DEATH ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS 60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY Electrical products can cause death, injury, or damage to property. Installation of this product must be carried out by a qualified electrician, in compliance with SANS 10142 or corresponding regulations of the country of installation. On completion of installation, the Certificate of Compliance must be updated. For non user replaceable light source: The light source contained in this luminaire shall only be replacedby the manufacturer or his/her service agent or a similar qualied person ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION. WARNING Remote Electronic Control Device ELECTRIC SHOCK HAZARD This equipment is to be serviced by trained personnel only.

This product should be installed by a competent person i.e. Qualified electrician.

This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current. The product must be regularly maintained, including the replacement of lamps/LED timeously. This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death. This product is not a toy, please keep away from children. This product may contain small parts that can be swallowed. Use only the correct light bulbs/LED as stipulated on the carton for the product. Any modifications of this product after supply will result in the guarantee being void. Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton Coastal humidity can affect the longevity of the light fitting over time. Be sure to follow the steps in the order given. Read instructions carefully. Important Safety Instructions 4 5 6 3 3. Before installing the tting, ensure the tting is level with the ground, to ensure the tting does not collect water. 4. Insert the plastic sleeve into cavity. Feed the electrical cable through the When installing in cement or paving, ensure there is a drain pipe under the cavity, under the gravel. DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE. EARTH – (Green/Yellow) to terminal marked E. SWITCHED LIVE – (Red or Brown) to terminal marked L 5. Connect the Switched Live (S/L), Neutral (N) and Earth (E) cable(s) to the terminal block. NEUTRAL – (Black or Blue) to terminal marked N Ÿ The amount of ttings on one circuit can be innite, this depends on the circuit design by the engineer on site. Ÿ Recommended cable thickness is 1.5mm on the 50m circuit. Ÿ The ttings can be looped 6. To install multiple ttings: 230 VAC Supply Friction t the luminaire into plastic sleeve. 7. Insert the Bilux Inground Luminaire body into plastic sleeve. Ensure inground luminaire is ush to nished oor level. DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE. 8. Rell the cavity and ensure the tting is level with the nished oor level, to eliminate water collection on the tting. Switch on power supply. Square Round Water collecting area Finished oor level (FFL) (FFL) Incorrect installation Correct installation Finished oor level (FFL) (FFL) 3 4 5 8 7 6 DO NOT PLUG (CONNECT) WHEN LIVE AS IT WILL CAUSE DAMAGE TO THE LUMINAIRE. Replaceable electrical components by end user Replaceable electrical components by end user REMOTE CONNECTION ELECTRICAL CONNECTION Replaceable electrical components by end user Luminaire -Red/Brown (+) -Green/Yellow -Black/Blue (-) E N L Main electrical supply Red/Brown- Green/Yellow- Black/Blue- 220 ~ 240V AC 50 Hz 7 Finished oor level (FFL) (FFL)

Other Outdoor Light Manuals