Regent Lighting Solutions Bilux Inground Installation Instructions
Read Online
Read the Regent Lighting Solutions Bilux Inground Installation Instructions online using the built-in PDF viewer.
Text of the manual
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
1
2
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
DO NOT CONNECT THE LUMINAIRE LIVE
Bilux Inground
Ø90mm
Hole diameter
145mm
Hole depth
Ensure there is a drain under the
substrate when installing the tting into
paving or cement
Drainage detail spec by Civil
Engineer.
2. Create a cavity for tting in the
ground/paving at the required position.
NB: GRAVEL FOR DRAINAGE: Lay at least
50mm of 13mm or 19mm Chip Stones
beneath the well of the cavity and
check drainage efciency.
DRAIN
GROUND
PAVING/
CEMENT
13/19mm Chip
Stones
3 - 13 MAIN REEF SERVICE ROAD, CORNER
SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA,
JOHANNESBURG. SOUTH AFRICA.
TEL : +27 11 474 0171
www.regentlight.co.za
REGENT LIGHTING A DIVISION
OF WAHL INDUSTRIES.
September 2021
98
53
Ÿ
Be sure the electricity to the system
you are working on is isolated.
Ÿ
If the main supply power (live) is on,
it will cause damage to the
luminaire.
Ÿ
Ambient temperature: Ta 36ºC
Ÿ
IP rating according to IEC 60598-1:
-Gear compartment: IP65
Ÿ
Mounting: In-ground installation
-Optical compartment: IP65
Ÿ
Control gear weight: 220V - 240 V
AC 50 Hertz
1
2
1. Selected the required position for the luminaire.
Create cavity in for plastic sleeve.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
Bilux Inground
Remote Electronic Control Device
WARNING
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
50
Bilux Inground
Save These Instructions for Future Reference
Regent Lighting reserves the right to change specifications modify designs and discontinue items
without incurring obligation and whilst every effort is made to ensure that descriptions, specifications
and other information in this catalogue are correct, no warranty is given in respect thereof and the
company shall not be liable for any error therein.
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING
WARNING: TO AVOID FIRE, SHOCK OR DEATH
ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH
SANS 60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY
Electrical products can cause death, injury, or damage to property.
Installation of this product must be carried out by a qualified electrician,
in compliance with SANS 10142 or corresponding regulations of the
country of installation. On completion of installation, the Certificate of
Compliance must be updated.
For non user replaceable light source: The light source contained in this luminaire
shall only be replacedby the manufacturer or his/her service
agent or a similar qualied person
ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED ELECTRICIAN
PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.
WARNING
Remote Electronic Control Device
ELECTRIC SHOCK
HAZARD
This equipment is to be
serviced by trained
personnel only.
This product should be installed by a competent person i.e. Qualified electrician.
This product requires a constant stable electrical supply 220V - 240V VAC 50Hz - alternating current.
The product must be regularly maintained, including the replacement of lamps/LED timeously.
This product could be HAZARDOUS if not used correctly, it could cause electric shock, serious bodily harm or death.
This product is not a toy, please keep away from children.
This product may contain small parts that can be swallowed.
Use only the correct light bulbs/LED as stipulated on the carton for the product.
Any modifications of this product after supply will result in the guarantee being void.
Spare parts may become unavailable over time.Items can vary slightly from the picture on the carton
Coastal humidity can affect the longevity of the light fitting over time.
Be sure to follow the steps in the order given.
Read instructions carefully.
Important Safety Instructions
4
5
6
3
3. Before installing the
tting, ensure the tting is
level with the ground, to
ensure the tting does
not collect water.
4. Insert the plastic sleeve into
cavity.
Feed the electrical cable
through the
When installing in cement or
paving, ensure there is a drain
pipe under the cavity, under
the gravel.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
EARTH – (Green/Yellow) to
terminal marked E.
SWITCHED LIVE – (Red or Brown)
to terminal marked L
5. Connect the Switched Live
(S/L), Neutral (N) and Earth (E)
cable(s) to the terminal block.
NEUTRAL – (Black or Blue) to
terminal marked N
Ÿ
The amount of ttings on
one circuit can be innite,
this depends on the circuit
design by the engineer on
site.
Ÿ
Recommended cable
thickness is 1.5mm on the
50m circuit.
Ÿ
The ttings can be looped
6. To install multiple ttings:
230 VAC Supply
Friction t the luminaire into
plastic sleeve.
7. Insert the Bilux Inground
Luminaire body into plastic
sleeve.
Ensure inground luminaire is
ush to nished oor level.
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
8. Rell the cavity and ensure
the tting is level with the
nished oor level, to eliminate
water collection on the tting.
Switch on power supply.
Square
Round
Water collecting area
Finished
oor
level
(FFL)
(FFL)
Incorrect installation
Correct installation
Finished
oor
level
(FFL)
(FFL)
3
4
5
8
7
6
DO NOT PLUG
(CONNECT) WHEN
LIVE AS IT WILL CAUSE
DAMAGE TO THE
LUMINAIRE.
Replaceable
electrical
components
by end user
Replaceable
electrical
components
by end user
REMOTE
CONNECTION
ELECTRICAL CONNECTION
Replaceable
electrical
components
by end user
Luminaire
-Red/Brown (+)
-Green/Yellow
-Black/Blue (-)
E
N
L
Main electrical supply
Red/Brown-
Green/Yellow-
Black/Blue-
220 ~ 240V AC 50 Hz
7
Finished
oor
level
(FFL)
(FFL)