1 (844) LIGHTCLOUD

1 (844) 544-4825 [email protected] WE’RE HERE TO HELP: 1 (844) LIGHTCLOUD © RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647 Custom manufactured in China 1 (844) 544-4825 [email protected] Lightcloud is a commercial wireless lighting control system. It’s powerful and flexible, yet easy to use and install. Learn more at lightcloud.com

This device complies with Part 15 of the FCC Rules. Operation is subject to

the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note: This device has been tested and found to comply with the limits for Class A digital devices pursuant to Part 15A Subpart B, of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. To comply with the FCC's RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. CAUTION: Changes or modifications to this equipment not expressly approved by RAB Lighting may void the user’s authority to operate this equipment. Hello The Lightcloud Controller Mini is a remotely controlled switch and 0-10V dimming device. Product Features Wireless Control & Configuration Switching up to 4.2A 0-10V Dimming Power Monitoring Patent Pending

POWER MEASUREMENT: The Lightcloud Controller is capable of

measuring the power usage of the attached circuit. POWER LOSS DETECTION: If mains power to the Controller is lost, the device will detect this and alert the Lightcloud application. EMERGENCY DEFAULT: If communication is lost, the Controller may optionally fall back to a specific state, such as turning the attached circuit on. Controller requires constant, unswitched power. Any wires not in use must be capped of or otherwise insulated. This product should only be installed by a qualifed electrician and in compliance with local and national electrical codes. ! Specifications PART NUMBER LCCONTROL/MINI INPUT 120V-277VAC, 60Hz <0.8W (Standby and Active) MAXIMUM SWITCHED LOAD RATINGS For Control of Electronic Ballast (LED) and Magnetic Ballast Electronic/Tungsten: 4.2A @120VAC Inductive/Resistive: 4.2A @120VAC, 1.8A @277VAC OPERATING TEMPERATURE -35ºC to +60ºC OVERALL DIMENSIONS 1.6" diameter, 3.8" length 1/2" NPT Mount, Male 22AWG pigtails 18AWG pigtails WIRELESS RANGE Class 2 IP66 Rated Indoor and Outdoor Rated Wet and Damp Location Plenum Rated Line-of-Sight: 1000 feet Obstructions: 100 feet

What You Need

Lightcloud Gateway A Lightcloud installation requires at least one Lightcloud Gateway to manage your devices. 1 (844) LIGHTCLOUD or 1 (844) 544-4825 [email protected] WE’RE HERE TO HELP: 1 (844) LIGHTCLOUD or 1 (844) 544-4825 [email protected] WE’RE HERE TO HELP: Functionality Configuration Operating Modes To configure Lightcloud products, use the Web Application (control.lightcloud.com) or call 1(844)LIGHTCLOUD. CONTROLLER: Provides switching and dimming for a single zone. REPEATER: Extends the Lightcloud mesh network without controlling a load. SENSOR (REQUIRES OPTIONAL SENSOR MODULE): Provides occupancy, vacancy, and daylight harvesting.

Confirm Device Connectivity

Confirm Status Indicator is Solid Green (see details below) Log on to www.lightcloud.com or call 1 (844) LIGHTCLOUD 6 Commission your devices To add new devices to your Lightcloud network, call RAB at 1 (844) LIGHTCLOUD, or email us at [email protected]. 4 Power up GREY GREY MODULAR MODULAR RED RED PURPLE PURPLE WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK 120-277 VAC Load or Fixture Controller Mini Lightcloud® Controller Mini Lightcloud® Solid GREEN when connected to your Lightcloud network. Blinking RED when not connected. The device will automatically continue trying to connect to a network in Setup Mode. Illuminates when the device receives a message and blinks the signal strength. 3 Blinks - Best signal 2 Blinks - Acceptable signal 1 Blinks - Unacceptable signal Consult the “Finding a Location” section for more information STATUS INDICATOR SIGNAL INDICATOR • Illuminated when device is powered • Press once to highlight this device in the Lightcloud Application • • Press twice and hold to set dim level Press twice to toggle circuit on and off • Press and hold for 10 seconds to remove this device from a Lightcloud network • Blinks when device is indicated from the Lightcloud Application DEVICE IDENTIFICATION BUTTON

Setup & Installation (cont’d)

Setup & Installation 1 OFF WARNING OFF Turn off power Find a Suitable Location 1a Lightcloud Installer Application 3a 3 Labeling your device Use these guidelines when installing devices: • If there is a clear line of sight between two Lightcloud devices, they can be placed up to 1000 feet apart. • If the two devices are separated by ordinary drywall construction, try to keep them within 100 ft. of each other. • Brick, concrete and steel construction may require additional Lightcloud devices to go around the obstruction. Lightcloud Gateway <= 100 ft. Add an additional Lightcloud Device to extend network range around corners BRICK, CONCRETE OR METAL WALL DRY WALL OR SIMIL AR When installing devices, it’s important to keep track of their Device IDs, installation locations, panel/circuit #s, dimming function, and any additional notes. To organize this information, use the Lightcloud Installer Application (A) or Device Table (B). Install the LC Installer Application: LC Installer is available for iOS and Android. Scan & Install Lightcloud Devices: Scan each device and assign to a room. It’s recommended that each device is scanned just before or just after being wired so no devices are missed. The more notes that are given, the easier it is to commission the system. Send to RAB: Once all of the devices have been added and organized, submit the information for commissioning. Device Table 3b For setup and maintenance, we provide two Lightcloud Device Tables with the Gateway: one that you can attach to your panel and one to hand off to a building manager. Attach the Device Identification stickers included witheach device to a row, then write in additional information, such as Zone name, Panel/Circuit Number, and whether or not a zone uses dimming. Device Scanner Enter Manually PLACE RECTANGLE TO FIT CODE ON LABEL Scan Device Code Device Info Save Cancel Device ID 0013A20040B62A4A Location Office Zone Name Office Lights Dimmable Power Monitoring Enter Device Information Repeat for Additional Devices Devices Add Device Send to RAB Office Light - ID 0013A20040B62A4A Controller Office Light - ID 0013A20040B62A4B Sensor Office Light - ID 0013A20040B62A4C Dimmer Office Light - ID 0013A20040B62A4D Daylight Office Light - ID 0013A20040B62A4E Touch Send to RAB Device Scanner Enter Manually PLACE RECTANGLE TO FIT CODE ON LABEL DEVICE IDs DEVICE 1D ZONE NAME PANEL/ CIRCUIT # DIMMING

Setup & Installation (cont’d)

2 Install your Lightcloud Controller 0-10V DIMMING NOTE: The National Electrical Code requires that low-voltage wiring used in the same enclosure as high-voltage wiring have an equal or better insulation rating. You may need to complete your low-voltage wiring in another enclosure or use a partition. 0-10V is a common method of low-voltage control of dimmable drivers and ballasts. Purple: 0-10V positive | Gray: 0-10V common 2a Install at a Junction Box (Indoor/Outdoor) 2b At Lighting Panel or Trough Space and code allowing, you may install Lightcloud devices directly in your breaker box or lighting panel. Alternatively, break out lighting circuits and install Lightcloud devices in a separate trough. Controller requires constant, unswitched power. ! When power switch is set to OFF Controller is disconnected from network OFF POWER LOAD DON’T Controller always has power and is connected to the network POWER LOAD DO WHITE BLACK Controller Mini Lightcloud® RED WHITE BLACK BLACK GRAY PURPLE To Load To Panel To Driver/Ballast MODULAR CABLE