Lockly DEADBOLT EDITION 7S Installation Manual
Text of the manual
Lockly® can be fitted for both right swing doors and left swing doors.
INSTALLATION OVERVIEW & PARTS LIST
U
SCAN & SAVE
LOCK SERIAL
ACTIVATION CODE
PGDXXXXXXXXX
XXXXXXXX
1.1 To complete installation, you would need the following:
1.2 Prepare door and remove existing lock. If necessary, use provided
Installation Template to prepare door.
Phillips Screwdriver
Flathead Screwdriver
Ruler
1-⅜" (35mm)
to 2" (50mm)
1" (25mm)
2-⅜" (60mm)
or 2-¾" (70mm)
2-⅛" (54mm)
STEP 1. PREPARE DOOR FOR INSTALLATION
2.1 Deadbolt slit hole must be aligned to the center of the door hole. If not
adjust as shown below:
2.1.1 Wear gloves during adjustment
to prevent pinching your hands
II. Hold the metal plate (c) and
twist the deadbolt body (d)
clockwise till it snaps to 2-3/8"
III. To return to default status,
while the deadbolt (b) is
extended, hold the metal
plate (c) and twist the dead-
bolt body (d) counter-clock-
wise till it snaps to 2-3/4"
(b)
(a)
(c)
(d)
(c)
(d)
I. Push the crank (a) to extend
the deadbolt (b)
Deadbolt at 2-3/4" (70mm)
(default shipping status)
STEP 2. ADJUST DEADBOLT AND INSTALL
2.2 Extend the deadbolt by inserting a
flat head screwdriver on the slit hole or
by pushing the crank towards the metal
face plate.
2.3 Insert the Deadbolt to the edge
door hole, make sure that its right side
up and the slit hole is in vertical position,
then secure with 2 screws (K)
K(2X)
STEP 2. ADJUST DEADBOLT AND INSTALL
1
2
3.2 Before placing the exterior assembly
on the door, make sure the torque blade is
in vertical position and the deadbolt is
extended.
Vertical
When installing the exterior assembly,
make sure the deadbolt is fully
extended and the slit hole is vertically
positioned on the bottom, the torque
blade should be inserted in a vertical
position.
M
B
Peel paper off the
Adhesive tape
3.3 Place the exterior assembly on the door
by inserting the torque blade on a vertical
position to the deadbolt slit hole and guide
the cable under the deadbolt. Secure with
the adhesive strips.
EXTERIOR VIEW
(1)
3.1 To secure Exterior Assembly of lock, peel the cover off the adhesive strips
STEP 3. INSTALLING THE EXTERIOR ASSEMBLY
4.1: Check the mounting plate
alignment to your door hole before
you peel of the cover off the
adhesive strip.
4.3: Without using any tools, insert 2
screws (G) on the side of the torque
blade. By using hand carefully, turn
the screws clockwise to catch the
thread, then counter clockwise to
make sure they are not cross threaded
and turns smoothly. Make five turns
before using a screw driver to tighten
the screws until the mounting plate is
securely placed to the door.
4.4: After securing the mounting
plate, use the physical key and try to
unlock/lock to check if the deadbolt
is moving and not stuck. Do not
forget to take out the key before
proceeding to next steps.
4.2: Place the mounting plate on the
interior side of the door. Guide the cable
to the opening ear on the side of mounting
plate and make sure the torque blade is at
the center of the mounting plate.
STEP 4. INSTALLING THE INTERIOR ASSEMBLY (F)
NOTE: In case you need to reinstall the
lock and disconnect the cable, make
sure to press the snap to release the
plug before carefully pulling it out. Do
not force to pull the plug as this may
result to lose connection and damage
the lock.
5.1 Plug the cable that is coming through the door into the Interior lock. Make sure you
match the direction of the plug correctly and matching the red side of the plug with the
red side on the lock. Secure the connection by ensuring the snap is inserted tightly.
STEP 5. INSTALLING THE INTERIOR ASSEMBLY (F)
STEP 5. INSTALLING THE INTERIOR ASSEMBLY (F)
5.2 Before placing the interior
assembly to the mounting plate,
ensure the thumb turn is vertical.
5.3 Place the interior assembly against the
mounting plate and make sure the torque
blade is inserted to the thumb turn shaft.
5.4 Secure the interior assembly with 2 screws (I)
Torque Blade
Thumb turn shaft
Push the thumb turn shaft into the
torque blade.
MAKE SURE IT IS IN THE
VERTICAL POSITION
First install 3 of the 4 batteries. Before installing the
last battery, press and hold the PROGRAM button
while installing the last battery until you hear
a beep from Lockly®.
Lockly® will then perform a self check and the
keypad screen will start to initiate. This self check
will automatically determine and set your door lock
to a left open or right open door.
+
-
+
-
+
-
+
-
RESET
PROGRAM
After the lock finished the self-check, do the 2-steps below to ensure your lock is properly
installed:
1. Manually lock and unlock your door by
using the thumb turn and the key to
make sure the deadbolt moves smoothly.
If you feel that there is a tight tension
while you are turning, it means that the
lock may have not been installed
straight. Go back to Step 2 and re-install
the lock.
IMPORTANT: If your lock is not properly
installed, it will open and close repeatedly
at times and/or it will reduce battery life.
2. Swipe your hand across the touchscreen
keypad, the lock will close. If the deadbolt
bounces and unlocks automatically, it means
that your lock was installed incorrectly. Go
back Step 2 to make sure your lock was
installed with the (a) deadbolt extended and
(b) the torque blade was inserted vertically
while the deadbolt was extended.
After you checked that the lock manually lock and unlock properly and deadbolt moves
smoothly, install the Battery Cover (H) and secure with screw.
STEP 6. INSTALLING BATTERIES
Install the door strike.
Install the door strike to your door frame and
proceed to the last step of installation of your
new lock. You may use our supplied door
strike or use your existing door strike as long as
the deadbolt moves smoothly in and out of
the door strike.
As there are many types of doors, you may
need to make slight adjustments so the
deadbolt moves smoothly. If anything is
rubbing against the deadbolt when locking
and unlocking, you may experience a
warning sound (rapid beeping) indicating that
the lock is experiencing misalignment or
something is blocking the deadbolt.
STEP 7. INSTALLATING DOOR STRIKE
Scan or visit Lockly.com/app
Congratulations! You have completed the Lockly® Model 7S physical lock installation. To
com-plete your setup, download the Lockly® app from the iOS or Google Play app Store
and follow on-screen instructions.
STEP 8. DOWNLOAD LOCKLY® APP
Always In The Know
Lock, unlock, and monitor your smart lock remotely, whenever,
wherever. The 2.4 GHz ( 802.11 b/g/n) Wi-Fi enabled hub connects
seamlessly to your smart lock and app, and provides live updates
whenever you need them including live access history without
connecting via Bluetooth to the lock.
Connected.
Wireless Door Sensors
No more worries wondering if your door was shut when you locked
your door. Included is a set of wireless door sensors that can
provide accurate information on the status of your door. Whether
it's securely shut or still open.
You can add live status monitoring and voice control capabilities to your Lockly® Smart Lock with
Amazon Alexa or Google Assistant via installing the Secure Link Wi-Fi Hub and Door Sensors
(Sold Separately)
Know it’s Closed.
PGH200
SECURE LINK
Amazon Alexa or Google Assistant
Configure your voice commands in your Alexa or Google Assistant
app to work with your smart lock. Give commands like “Is my front
door locked?” or “Lock my front door”
Smart Home Integration
Get one now to enable the above features.
https://lockly.com/hub
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
FCC Radiation Exposure Statement
The Secure Link Wi-Fi Hub complies with FCC radiation exposure limits set forth for an uncontrolled
environment. It should be installed and operated with minimum distance 20cm between the
radiator & your body.
IC WARNING
This device contains licence-exempt transmitter(s) that comply with Innovation, Science and
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following
two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired opera-
tion of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR
d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
IC Radiation Exposure Statement
This equipment meets the exemption from the routine evaluation limits in section 2.5 of RSS-102. It
should be installed and operated with a minimum distance of 20cm between the radiator and any
part of your body.
Cet équipement est conforme à l'exemption des limites d'évaluation habituelle de la section 2.5 de la
norme RSS-102. Il doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et
toute partie de votre corps.
WARNING: This product can expose you to chemicals including Lead, which
is known to the State of California to cause cancer. For more information go
to www.P65Wamings.ca.gov.