Qtx RP12 Operation & User’s Manual

Text of the manual

154.113UK User Manual

RP12 12-Channel DMX Relay Pack Item ref: 154.113UK User Manual Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty The 12CH DMX RELAY PACK can be controlled by DMX 512 console. Each output socket is controlled individually by one relay. It can be widely applied to entertainment hall, stage, social club and indoor building decoration. Front view: Rear view: - LED digital display for DMX addressing and work mode setting - universal DMX512 (1990) multiplexed digital control - DMX and Stand Alone operation modes There are two modes of operation: DMX: Either: 1, 2, 3, 6 or 12 channel. Manual control mode. Each mode can be selected by first pressing the MODE button followed by the UP / DOWN buttons and SET to confirm. Each of the modes is displayed below:

154.113UK User Manual

Control Panel Menu MODE manual SET UP manual UP/DOWN manual instruction DMX MODE Address ~ Sets the DMX starting address DMX Channels set The unit occupies 1 channels The unit occupies 2 channels The unit occupies 3 channels The unit occupies 6 channels The unit occupies 12 channels MANUAL CONTROL MODE Manual Channels set 12 output sockets occupy 1 channel 12 output sockets occupy 2 channels 12 output sockets occupy 3 channels 12 output sockets occupy 6 channels 12 output sockets occupy 12 channels Manual Channels Open/ close / :set channel 1 open :set channel 1 close / :set channel 2 open :set channel 2 close / :set channel 3 open :set channel 3 close / :set channel 4 open :set channel 4 close / :set channel 5 open :set channel 5 close / :set channel 6 open :set channel 6 close / :set channel 7 open :set channel 7 close / :set channel 8 open :set channel 8 close / :set channel 9 open :set channel 9 close / :set channel 10 open :set channel 10 close / :set channel 11 open :set channel 11 close / :set channel 12 open :set channel 12 close OTHER MODE Display on/off LED digital tube display always on LED digital tube display off Display normal/ inversed LED digital tube display normal LED digital tube display inversed Initializatio n mode Initialize the unit at the extra factory setting

154.113UK User Manual

DMX mode You can control devices individually via the sliders on your DMX-controller. Each of the values is listed below :1 channel mode CH No. DMX value Function CH1 000~010 CLOSE(No.1- 12 OUTPUT SOCKET) 011~255 OPEN(No.1-12 OUTPUT SOCKET) :2 channels mode CH No. DMX value Function CH1 000~010 CLOSE(No.1-6 OUTPUT SOCKET) 011~255 OPEN(No.1-6 OUTPUT SOCKET) CH2 000~010 CLOSE(No.7-12 OUTPUT SOCKET) 011~255 OPEN(No.7-12 OUTPUT SOCKET) :3 channels mode CH No. DMX value Function CH1 000~010 CLOSE(No.1-4 OUTPUT SOCKET) 011~255 OPEN(No.1-4 OUTPUT SOCKET) CH2 000~010 CLOSE(No.5-8 OUTPUT SOCKET) 011~255 OPEN(No.5-8 OUTPUT SOCKET) CH3 000~010 CLOSE(No.9-12 OUTPUT SOCKET) 011~255 OPEN(No.9-12 OUTPUT SOCKET) :6 channels mode CH No. DMX value Function CH1 000~010 CLOSE(No.1-2 OUTPUT SOCKET) 011~255 OPEN(No.1-2 OUTPUT SOCKET) CH2 000~010 CLOSE(No.3-4 OUTPUT SOCKET) 011~255 OPEN(No.3-4 OUTPUT SOCKET) CH3 000~010 CLOSE(No.5-6 OUTPUT SOCKET) 011~255 OPEN(No.5-6 OUTPUT SOCKET) CH4 000~010 CLOSE(No.7-8 OUTPUT SOCKET) 011~255 OPEN(No.7-8 OUTPUT SOCKET) CH5 000~010 CLOSE(No.9-10 OUTPUT SOCKET) 011~255 OPEN(No.9-10 OUTPUT SOCKET) CH6 000~010 CLOSE(No.11-12 OUTPUT SOCKET) 011~255 OPEN(No.11-12 OUTPUT SOCKET)

154.113UK User Manual

:12 channels mode CH No. DMX value Function CH1 000~010 CLOSE(No.1 OUTPUT SOCKET) 011~255 OPEN(No.1 OUTPUT SOCKET) CH2 000~010 CLOSE(No.2 OUTPUT SOCKET) 011~255 OPEN(No.2 OUTPUT SOCKET) CH3 000~010 CLOSE(No.3 OUTPUT SOCKET) 011~255 OPEN(No.3 OUTPUT SOCKET) CH4 000~010 CLOSE(No.4 OUTPUT SOCKET) 011~255 OPEN(No.4 OUTPUT SOCKET) CH5 000~010 CLOSE(No.5 OUTPUT SOCKET) 011~255 OPEN(No.5 OUTPUT SOCKET) CH6 000~010 CLOSE(No.6 OUTPUT SOCKET) 011~255 OPEN(No.6 OUTPUT SOCKET) CH7 000~010 CLOSE(No.7 OUTPUT SOCKET) 011~255 OPEN(No.7 OUTPUT SOCKET) CH8 000~010 CLOSE(No.8 OUTPUT SOCKET) 011~255 OPEN(No.8 OUTPUT SOCKET) CH9 000~010 CLOSE(No.9 OUTPUT SOCKET) 011~255 OPEN(No.9 OUTPUT SOCKET) CH10 000~010 CLOSE(No.10 OUTPUT SOCKET) 011~255 OPEN(No.10 OUTPUT SOCKET) CH11 000~010 CLOSE(No.11 OUTPUT SOCKET) 011~255 OPEN(No.11 OUTPUT SOCKET) CH12 000~010 CLOSE(No.12 OUTPUT SOCKET) 011~255 OPEN(No.12 OUTPUT SOCKET) Specifications Power supply 230Vac, 50Hz Maximum current input 30A Maximum current per channel 10A IEC outputs 12 Dimensions 440 x 205 x 88mm Weight 3.8kg This product is classed as Electrical or Electronic equipment and should not be disposed with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines. Errors and omissions excepted. Copyright© 2021 AVSL Group Ltd, Unit 2 Bridgewater Park, AVSL (Europe) Ltd, Unit 3D North Point House, Taylor Road, Trafford Park, Manchester. M41 7JQ. North Point Bus. Park, New Mallow Road, Cork, Ireland.

Other Relays Manuals