Omron S82J Manual
| Brand: | Omron |
| Category: | Power Supply |
| Model: | S82J (Manual ) |
| File Type: | |
| File Size: | — |
| Pages: | 20 |
Text of Omron S82J Manual
Omron S82J Switching Power Supply
S82J
Compact and Economical Switching Power Supplies with Capacities Up to 600 W
DIN Track Mounting Bracket Type Now Available
Power range from 10 W up to 600 W.
Output Voltages: 5 V, 12 V, 15 V, or 24 V.
Wide AC input range
10-/25-/50-/100-W, 24-V output models: 100 to 240 VAC on one body
100-W, 5-/12-/15-V output and 150-W models: 100 or 200 VAC selected automatically
300-/600-W models: 100 or 200 VAC selectable
Top terminal- and
Omron S82J Front-mounting Bracket Type
Configuration
Input
Voltage
Power
ratings
Output
voltage
Output
current
Front terminals
Top terminals
Connector
Open-frame
t
100 to
240 VAC
10 W
5 V
2 A
S82J-01005A
---
---
Ope
a
e
type
00 o
240 VAC
12 V
1 A
S82J-01012A
---
---
15 V
0.7 A
S82J-01015A
---
---
24 V
0.5 A
S82J-01024A
---
---
25 W
5 V
5 A
S82J-02505A
---
---
12 V
2.1 A
S82J-02512A
---
---
15 V
1.7 A
S82J-02515A
---
---
24 V
1.1 A
S8
Omron S82J DIN Track Mounting Bracket Type
Configuration
Input
Voltage
Power
ratings
Output
voltage
Output
current
Front terminals
Top terminals
Connector
Open-frame
t
100 to
240 VAC
10 W
5 V
2 A
S82J-01005AD
---
---
Ope
a
e
type
00 o
240 VAC
12 V
1 A
S82J-01012AD
---
---
15 V
0.7 A
S82J-01015AD
---
---
24 V
0.5 A
S82J-01024AD
---
---
25 W
5 V
5 A
S82J-02505AD
---
---
12 V
2.1 A
S82J-02512AD
---
---
15 V
1.7 A
S82J-02515AD
---
---
24 V
1.1 A
S82J-02524AD
Model Number Legend:
1.Power Ratings
010: 10 W
025: 25 W
050: 50 W
100: 100 W
150: 150 W
300: 300 W
600: 600 W
2. Output Voltage
05:
5 V
12:
12 V
15:
15 V
24:
24 V
3. Configuration
A:
Open-frame type, front terminals
B:
Open-frame type, top terminals
C:
Open-frame type, connector
D:
Covered type, front terminals
E:
Covered type, top terminals
F:
Covered type, connector
N:
Without Mounting Bracket
None: Enclosure type, front terminals with
Mount
Omron S82J 100 to 240 VAC input
100 or 200 VAC
(selected
automatically)
100 or 200 VAC
(selectable)
10 W
25 W
50 W
100 W
(24 V)
100 W (5,
12, 15 V)
150 W
300 W
600 W
Efficiency (typical)
67% min. (77% min. for 50-W, 24-V models)
83% min.
75.5%
min.
82% min.
Input
Voltage
100 to 240 VAC (85 to 264 VAC)
110 to 170 VDC (set the terminal (L) to + side) (see note1)
100 (85 to 132) or 200
(170 to 264) VAC
(selected
a
100 or 200 VAC
(selectable)
100 or 200 VAC
(selected
automatically)
100 to 240 VAC input
Item
600 W
300 W
150 W
100 W (5,
12, 15 V)
100 W
(24 V)
50 W
25 W
10 W
Other
Ambient temperature
Operating: See the derating curve in the Engineering Data section.
Storage: –25 to 65°C (with no condensation and icing)
Ambient humidity
Operating: 25% to 85%
Storage: 25% to 90%
Dielectric strength
3.0 kVAC, 50/60 Hz for 1 min (between all inputs and a
Ambient temperature (°C)
Covered-type
Load (%)
Ambient temperature (°C)
Standard Installation
Natural air-cooling
Forced air-cooling (1 m3/min)
Forced air-cooling
(1 m3/min)
Natural air-cooling
Note:
The derating curve shown is for
standard installation. The derating
curve depends on the mounting
direction of the Power Supply.
300-W Model
600-W Model
Sing
Omron S82J 10- to 300-W Models
The Power Supply is provided with an overload protection function
that protects the load and the power supply from possible damage
by overcurrent. When the output current rises above 105% to 160%
of the rated output current (105% of the rated output current for
300-W models), the protection function is triggered, decreasing the
output voltage. When the output current falls within the rated range,
the ove
S82J-010 (10 W)
S82J-025 (25 W)
S82J-050 (50 W)
Drive
control
circuit
+V
–V
DC Output
AC(L)
AC(N)
Fuse*
Noise filter
Inrush current
protection circuit
Rectifier
Rectifier
Detector
Photocoupler
Input
Input
AC(L)
AC(N)
Fuse (3 A)*
Noise filter
Control circuit
Overload
detection
circuit
Photocoupler
Overload
detection
circuit
+V
–V
DC Output
Inrush current
protection
circuit
Rectifier
Smoothing
circuit
Rec
Fuse (5 A)
Noise filter
Control circuit
Overload
detection
circuit
Photocoupler
Detector
+V
–V
DC Output
S82J-10024 (100 W, 24-V Output)
Rectifier
Inrush current
protection
circuit
Smoothing
circuit
Rectifier and
smoothing
circuit
Photocoupler
Overload
detection
circuit
+V
–V
DC Output
Input
AC (L)
AC (N)
Fuse (8 A)
Noise filter
Inrush current
protection circuit
Rectifier
Control circuit
Overcurrent
detector
Rectifier a
S82J-60024 (600 W)
Parallel operation selector
100/200 V (selectable)
Note:
Short-circuit the input voltage selector
terminals if the input is 100 to 120 VAC.
Keep the terminals open if the input is 200
to 230 VAC.
Fuse
20 A
Noise filter
Inrush current
protection circuit
Rectifier and
smoothing
circuit
Detector
Photocoupler
Photocoupler
Control
circuit
Overcurrent
detector
Fan
Overheat
detector
Overvoltage
detector
Rectifier and
smoothing cir
All units are in millimeters unless otherwise indicated.
Front-mounting Bracket Type
S82J-010 (10 W)
S82J-025 (25 W)
S82J-050 (50 W)
Mounting Holes
(Surface Screw Mounting)
Side Mounting
Bottom Mounting
3.5
90±1
97±1
65±0.5
5
82±0.5
Two, 3.5 dia.
3.5 dia.
78±0.5
6.5
M3.5 terminal
screw
3.5
28
35±1
50±0.5
17.5
15
Two, M3
For track mounting bracket
(4 mm deep max.)
12 max.
5
82±0.5
65±0.5
Two, M3
78±0.5
Two,
Omron Power Supply Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
G3PC |
#6KNT45: G3PC Power Supply Datasheet |
8 | 1041 | 157 | 24-05-2026 | |
S8TS |
Guide: Omron S8TS (A58P1G, Upd.04-09-2026) |
1 | 1275 | 204 | 04-09-2026 | |
S8FS-C Series |
Omron Power Supply Manual (File: PDF, 02-10-2026) |
42 | 226 | 39 | 02-10-2026 | |
ZFV - V2.0 |
ZFV - V2.0 (Power Supply ePDF User Manual, #2MB1L3) |
110 | 844 | 203 | 17-09-2026 | |
Powli BU3002SW |
Guide: Omron Powli BU3002SW (G97CF4, Upd.30-08-2026) |
93 | 1387 | 320 | 30-08-2026 |