MICRO-AIR EasyStart 364 Relearning
Read Online
Read the MICRO-AIR EasyStart 364 Relearning online using the built-in PDF viewer.
Text of the manual
NOTE: Power should always be turned off
when working with electrical components
Relearning EasyStart – 364
1. Remove the cover and find the jumper (JP1) Please note that you will need to move the
black start capacitor slightly to fully expose the jumper pins.
NOTE: Power should always be turned off
when working with electrical components
2. Move the jumper block from the Factory Default to the Relearn position as shown in
the below examples. We recommend using a pair of needle nose plyers or tweezers.
3. Apply power to EasyStart and start the compressor. Run it for 10 seconds then turn
power off.
Factory Default (across pins 3 and 4)
Relearn Position (across pins 4 and 6)
4. Move the jumper block back to the factory position. (across pins 3 and 4). Put the
cover back on and do four more starts. Learning is finished.