4. When the test leads are plugged into the current input
terminals, do not connect the test leads to any circuit in parallel or it will damages the fuses and the instrument. 5. After the completion of all the measurement operation, you should first turn off the power & then disconnect the test leads & the measured circuit connection, Especially to high current measurement. 6. It is forbidden to input more than 36V DC, 25V AC Voltage between the current jack & the “COM” jack. 3000 AC mA SELECT HOLD MAX/MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 75 ...
The specific operation
is as follows: The figure on the right shows the schematic diagram of DC mA . 1. Insert the black meter pen into the “COM” jack and the red meter pen into the “V/Ω/Hz” jack; the default value of the current is DC, trigger the “SELECT” key to switch between AC & DC current. 2.Turn the range switch to the corresponding DC/AC m A gear, trigger “ SELECT” to select AC m A and then put the meter into the circuit to be measured. The measured current value and the current polarity of the red test point will also be displayed at the same time ...
TRUE RMS AUTORANGING
DIGITAL MULTIMETER This Test Certificate warrantees that the product has been inspected and tested in accordance with the published specifications. The instrument has been calibrated by using equipment which has already been calibrated to standards traceable to national standards. MODEL NO. _____________ KM 60-T SERIAL NO. ___________ DATE: ___________ ISO 9001 REGISTERED QC PASS KUSAM-MECO 23 WARRANTY Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period ...
2.Turn the range switch
to the corresponding DC/ACA position. The default value is AUTO DC6A/10A. Then connect the meter to the circuit under test. The measured current value and the current polarity of the red test point will be displayed on the screen at the same time. trigger “SELECT” key to select AC current AC6A/10A: NOTE : 1.The instrument series connection to the circuit pending to test before the circuit should be the first power off. 2. The maximum input current is 10A (depending on the insertion position of the red meter pens), not more than 10 secon ...
Accuracy (reading data of % + least significant digits) accuracy
storage temperature (23.5)°C, Relative Humidity <75%. DC Voltage AC Voltage DC Current AC Current Resistance Diode\On-off Frequency Capacitance NCV Zero line /Fire Wire Test Full unit symbol Backlight manual / Auto off True RMS measurement. Performance (Note “ ” Indicates that the instrument has this function ELECTRICAL SPECIFICATIONS : 04 5.000 DC V SELECT HOLD MAX/MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 750V DC 1000V DC 10A COM VWHzmA mA out AUTO POWER OFF TRUE RMS OFF V V ~ NCV W Hz % ...
This series of instruments is designed to comply with IEC1010
(International Electro-technical Commission promulgated safety standards), before use, please read the safety precautions. 1. When measuring the voltage, please input the limit voltage of DC 1000V or AC 750V rms. 2. The voltage below 36V is safe voltage. When measuring above 36V DC & 25V AC voltage, check whether test pen is reliable contact or right connected or good insulation properly, whether insulation is good & so on, in order to avoid electric shock. 3. When Change function & range, test pen ...
Kusam-meco KM 60-T user guide recommended for: M3511A, KM-459, KM 2777, KM 829, KM 807s.
⚠️ Download Safety
The Multimeter Operation manual (14 pages) is completely safe to download (last scan date: 10/01/2026).
Related PDF Instructions for Kusam-meco KM 60-T:
-
Kusam-meco KM-CAL-801 Test Equipment Operation & user’s manual
KM-CAL-80110 -
Kusam-meco KM 086 Measuring Instruments Operation manual
KM 08617 -
Kusam-meco KM 2805 MK-1 Measuring Instruments Instruction manual
KM 2805 MK-135 -
Kusam-meco 6060 Test Equipment Operation manual
606015 -
Kusam-meco KM 2240 Measuring Instruments Operation manual
KM 22408 -
Kusam-meco KM 035 Measuring Instruments Operation manual
KM 03513
Multimeter Equipment: Frequently Requested
-
Fluke 789 Multimeter
27.02.2026Product instruction manual for the Fluke 789 Multimeter. This manual covers installation, operation, and configuration options, replacement parts, reset instructions.789, 40 -
Chauvin Arnoux C.A 5277 Multimeter
05.06.2026Instruction guidebook for the Chauvin Arnoux C.A 5277 Multimeter. This guide provides technical guidance on diagnostic information, cleaning instructions, service instructions.C.A 5277, 23 -
Triplett 630 Type 5 Multimeter
04.06.2026User setup guide for the Triplett 630 Type 5 Multimeter. It outlines installation and usage procedures, cleaning instructions, basic operation.630 Type 5, 33 -
Metrix MX 20 Multimeter
12.05.2026Product reference manual for the Metrix MX 20 Multimeter. This documentation explains configuration and safety precautions, technical overview, troubleshooting guides, device reset instructions.MX 20, 68 -
UNI-T UT81C Multimeter
04.03.2026User instruction manual for the UNI-T UT81C Multimeter. This guide offers guidance on service procedures, interface navigation, error handling.UT81C, 55 -
VOLTCRAFT VC-655 BT Data Loggers
19.04.2026Product instruction manual for the VOLTCRAFT VC-655 BT Data Loggers. It explains firmware updates, device features, usage recommendations, product maintenance.VC-655 BT, 8
Have some Questions about Kusam-meco KM 60-T Device?
Get valuable and actionable advices from other Kusam-meco KM 60-T device users. Describe your problem or question, regarding the using of KM 60-T, in as much detail as possible, and other users will be able to answer you.