KI Tattoo Flex Screen Assembly Instructions Manual
Text of the manual
Tattoo™ Screens - Table of Contents
Assembly Instructions
Tattoo™ Screens
Tools Required........................................................................................3
Unloading...............................................................................................4
Flex and Spine Screen - Overview...........................................................5
Spine Screen
Spine Screen Foot Assembly..................................................................5
Leveling & Connecting Spine Screens....................................................6
Leveling & Connecting Change of Height Spine Screens........................8
Spine Screen Electrical
Electrical Installation - Overview.............................................................9
Duplex Receptacle Installation................................................................9
Screen-to-Screen 10-Wire Jumper Installation.....................................10
Pass-Through Screen-to-Screen 10-Wire Jumper Installation..............11
10-Wire Top Power Infeed (End-of-Run) Installation.............................12
10-Wire Top Power Infeed (In-Line) Installation....................................14
10-Wire Top Power Infeed (In-Line) Installation with Flex Screen.........16
Power Pole Extension Installation.........................................................19
10-Wire Base Power Infeed (End-of-Run) Installation...........................20
Base Raceway Power Infeed Installation................................................21
10-Wire Base Power Infeed Spacer (End-of-Run) Installation...............22
10-Wire Base Power Infeed Spacer (In-Line Installation.......................23
10-Wire Base Power Infeed Spacer (In-Line) Installation with Flex
Screen Intersection...............................................................................26
Hardwired Electrical Base Power Infeed Trim Installation......................30
Data Installation....................................................................................31
Spine Screen Trim
End-of-Run Spacer Installation.............................................................32
In-Line Spacer Installation....................................................................33
In-Line Spacer Installation with Flex Screen Intersection......................34
10-Wire Base Trim Installation..............................................................38
End-of-Run Vertical Trim Installation....................................................39
Change-of-Height Trim Installation.......................................................40
Flat Aluminum Top Cap Installation......................................................41
Flex Screen Configurations
In-Line Flex Screens.............................................................................42
Flex Screen Corner Intersections..........................................................43
Flex Screen Mid-Panel Intersections.....................................................44
Flex Screen 3-Way Intersections...........................................................45
Spine & Flex Screen 3-Way Intersections.............................................46
Additional Information
Topper Kit Installation...........................................................................47
Slide Panel Installation.........................................................................48
Coat Hook Installation...........................................................................49
Tattoo™ Screens - Tools List
Assembly Instructions
Power Drill with
Magnetic Bit Holder
Torx Bits
(T-25, T-30)
Phillips Bits
(#2, #3)
Laser Alignment Tool
Utility Knife
Tools Required
•
Power Driver with Magnetic Bit
Holder
•
Drive Bits T-25, T-30 and Phillips
•
Laser Level
•
A Pair of Thin Flat Bars
•
Utility Knife
•
Tape Measure
•
Miter Saw with Non-Ferrous Blade
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Flat Pry Bar
Miter Saw with Non-Ferrous Blade
Note: Cut station must be equipped with
stands, tarps, and a shop vac.
Tape Measure
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Unloading
Assembly Instructions
Unloading
Warning: Shipping skids are designed
to be moved with a pallet jack or slid
along the floor using a fork lift. If no
dock is available to remove the skid
at grade from the bed of the trailer, the
screens must be unloaded by hand one
at a time. FAILURE TO COMPLY MAY
RESULT IN DAMAGED PRODUCTS
AND/OR INJURY.
1. It is highly recommended that the
screens be removed and staged with
protection between the screens. Lean
the screens vertically against a wall
at a slight angle. If screens must be
leaned on edge, no more than 12
screens of like size should be in one
leaning stack. Stack screens with the
padding against the wall or on the
floor to prevent damage.
2. As each screen or component is
unloaded, it should be checked
against the packing list and/or
space-plan layout (shop drawing)
to ensure completeness of order. All
items are identified by both a part
number sticker and a carton number
sticker.
3. Inspect each panel for shipping
damage as it is removed from the
truck. If damage exists, notify KI of
carton number, type of damage and
probable cause of damage within
24 hours of unloading.
4. Damage must be indicated on
bill of lading to file a freight
claim. Report all other on-site
damage as soon as possible to
ensure prompt replacements.
To transport panels on site, use
a well-padded drywall cart to
eliminate damage of edges and
finish.
Tattoo™ Screens - Spine Screen Foot Assembly
Assembly Instructions
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Flex and Spine Screen - Overview
Note: Flex Screens ship mostly
assembled, except for when topper
accessories are specified. Spine
Screens ship without base raceway
trim and feet attached. Feet must
be assembled to the bottom of each
Spine Screen as they are unpacked.
Figure 1
Spine Screen
foot
1/ -20 x 2”
T-30 Torx screws
4
pass-through
ankle
Detail A - Bottom View of Spine Screen
“NE” holes
face to center
1/ -20 x 2”
T-30 Torx
screw
4
feet
( NE” mounting holes
facing towards the center
of the screen)
Detail B
pass-through
ankle
Spine Screen
height-adjustable glides
twisted in fully for
screen to be at their
lowest position)
foot
Note: If Spine Screens are not being
assembled, go now to “Flex Screen
Configurations” instructions on
page 42.
Important: If the Spine Screen
System is to be installed with New
York City electrical, proceed to the
Tattoo Screen System - New York
City Electrical Assembly Instruction
(KI-AI-000045) before proceeding
to "Spine Screen Foot Assembly"
instructions on this page.
Spine Screen Foot Assembly
1. Carefully lay Spine Screen flat onto a
soft, protective surface (Figure 1).
Note: An “EL” and “NE” are
embossed on the bottom of each
foot, corresponding to wider and
narrower hole patterns respectively.
Only the wider “EL” holes are used
for mounting the feet to the Spine
Screen pass-through ankle. But, the
“NE” holes (narrower hole pattern)
are referenced below to orient inward
for correct installation of the foot.
Take care and follow the directions
below when positioning feet for
installation. If feet are not installed in
the correct orientation, screens will
not gang in-line with each other and
disassembly and correct re-assembly
will be required.
2. Orient each foot such that the wider
positioned “EL” mounting holes are
to the outside of the Spine Screen
unit and the narrower positioned
“NE” holes are positioned closer to
the center (Detail A), then position
each foot over the corresponding
mounting holes of the pass-through
ankle. Secure each foot to the
pass-through ankle using two
1/4-20 x 2” T-30 Torx screws
(Figure 1 & Detail A).
3. Twist the height-adjustable glides
in clock-wise, fully to the bottom of
the foot. This will allow for upward
adjustment of the screen, if required
at the final installation location
(Figure 1 & Detail B).
Tattoo™ Screens - Spine Screen Leveling & Connecting
Assembly Instructions
Leveling & Connecting Spine
Screens
Note: A single Spine Screen may
not be used as a freestanding screen
on its own. The Spine Screen must
always be mechanically attached
to another Spine Screen (with or
without electrical).
1. Check to make sure all
height-adjustable glides are
adjusted so the screens are at their
lowest position as illustrated in
Detail F on page 8. If glides are not
adjusted down fully to the bottom of
the screen, reference “Spine Screen
Foot Assembly” instructions on
page 5, step 3.
2. Carefully turn Spine Screens to the
upright position, and move to their
final installation location in-line to
each other per the space-planning
layout (Figure 2).
Important: Know and mark all high
and low spots on the floor. Make sure
to twist adjustable glides appropriate
to floor conditions. Always begin
assembling screens together at the
highest point of an un-even floor.
Note: If in-line Spine Screens
include change-of-height screen(s),
go now to “Leveling and Connecting
Change-of-Height Spine Screens”
instructions on page 8.
Using a laser alignment tool,
determine and mark all high and
low points on the floor. Adjust the
level and height of the Spine Screen,
beginning at the highest point in the
floor first. To raise the screen, rotate
the glide counter-clockwise. To lower
the screen, rotate the glide clockwise.
Only extend the glides as needed
to make the screen level and plumb
(Figure 2).
Note: If an in-line infeed power pole
or spacer is specified between two
screens, it must be installed between
the designated screens before
connecting the screens. If an in-line
10-wire top infeed power pole is to
be installed, reference “10-Wire Top
Power Infeed (In-Line) Installation”
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Spine Screen
(first)
Spine Screen
(second)
height-adjustable
glides (adjusted for
panels to be in the
lowest position)
height-adjustable glide
(adjusted for the
panel to be in the
lowest position)
laser
alignment
tool
Figure 2
molding
clips
bottom
screen
connector
Detail C
bottom
screen
connector
molding clip
(come installed
from factory)
vertical
frame
channel
Detail D
Spine
Screen
Spine
Screen
instructions on page 14. If an
in-line 10-wire top infeed power pole
is to be installed with a Flex Screen
intersection, reference “10-Wire Top
Power Infeed (In-Line) Installation
with Flex Screen Intersection”
instructions on page 16. If an
in-line 10-wire base infeed spacer is
to be installed, reference “10-Wire
Base Power Infeed Spacer (In-
Line) Installation” instructions on
page 24. If an in-line 10-wire base
infeed spacer with a Flex Screen
intersection is to be installed,
reference “10-Wire Base Power
Infeed Spacer (In-Line) Installation
with Flex Screen Intersection”
instructions on page 26. If an in-line
spacer is to be installed, reference
“In-Line Spacer Installation”
instructions on page 33. If in-line
spacer is to be installed with a
flex screen intersection, reference
“In-Line Spacer Installation with Flex
Screen Intersection” instructions on
page 34. After the spacer or in-line
infeed power pole has been installed,
proceed to step 4 on this page to
connect Spine Screens.
3. Locate the bottom screen connector
(Detail C) and take note that it
contains two molding clips installed,
one at each side. Figure 2 shows the
molding clips separated
for clarity. Each clip will press-fit
into the appropriate screen’s channel
to help join screens together.
Assure that the first Spine Screen
is level and plumb, and at its final
installation location. Position the
bottom screen connector up to the
bottom of the vertical channel of the
first Spine Screen and firmly press
it in, oriented as shown (Figure 2 &
Detail C).
4. Position the second Spine Screen
in-line against the first Spine Screen,
which has been adjusted level
and plumb. Level and plumb the
second screen to the first screen by
twisting the height-adjustable glides
clockwise or counter-clockwise until
the frame’s vertical edges are aligned
and tops of screens are at the same
height. Connect the screens together
by holding the first Spine Screen in
place while pressing firmly on the
second, into the first so the bottom
screen connector in the first engages
the second screen (Figure 2 &
Detail D).
5. Repeat the process in steps 4 & 5 to
add, level, plumb and connect the
remaining screens in the row. If the
remaining screens to be connected
are different heights, go now to
“Leveling & Connecting
Change-of-Height Spine Screens”
instructions on page 8, step 2.
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Leveling & Connecting
Assembly Instructions
6. Ensure that the two in-line Spine
Screens to be joined are tight to each
other and properly aligned plumb
and level. If screens are not plumb
and level to each other, reference
“Leveling & Connecting Spine
Screens” instructions on page 6.
7. At the location where two in-line
screens will be joined at the top,
place a connector plate over the
notch in both horizontal frames.
Bridge the frames with the connector
plate and align the four mounting
holes in the screens with the
mounting holes in the connector
plate. Secure the plate to the screen’s
horizontal frame using four
#10-24 x 3/8” Torx screws
(Figure 3 & Detail E).
Note: Do not install any trim at this
time. Trim is last to be installed, at a
later time.
Figure 3
Spine Screen
Spine Screen
connector
plate
#10-24 x / ”
Torx screws
3
8
horizontal
frame
horizontal
frame
Detail E
Spine Screen
Spine Screen
connector
plate
horizontal
frame
#10-24 x / ”
Torx screws
3
8
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Leveling & Connecting
Assembly Instructions
Spine Screen
(48” high shown)
Spine Screen
(54” high shown)
height-adjustable
glides (adjusted for
panels to be in the
lowest position)
height-adjustable glide
(adjusted for the
panel to be in the
lowest position)
laser
alignment
tool
Figure 4
molding
clips
screen
connector
Detail F - Side View of Screen
height-adjustable
glide (adjusted for
the screen to be
in the lowest
position)
base
raceway
trim
Note: Adjust the height of each screen
to the lowest position by rotating the
height-adjustable glides clockwise.
Detail G
screen
connector
molding clip
(come installed
from factory)
vertical
frame
channel
Detail H
Spine
Screen
Spine
Screen
Leveling & Connecting
Change-of-Height Spine Screens
Note: A single Spine Screen may
not be used as a freestanding screen
on its own. The Spine Screen must
always be mechanically attached
to another Spine Screen (with or
without electrical).
Important: Know and mark all high
and low spots on the floor. Make sure
to twist adjustable glides appropriate
to floor conditions. Always begin
assembling screens together at the
highest point of an un-even floor.
1. Using a laser alignment tool,
determine and mark all high and
low points on the floor. Adjust the
level and height of the Spine Screen,
beginning at the highest point in
the floor first. To raise the screen,
rotate the glide counter-clockwise.
To lower the screen, rotate the screw
clockwise. Only extend the glides as
needed to make the screen level and
plumb (Figure 4 & Detail F).
2. Locate the screen connector
(Detail G) and take note that it
contains eight molding clips
installed, four at each side. Figure 4
shows the molding clips separated
for clarity. Each clip will press-fit into
the appropriate screen’s channel to
help join screens together. Assure
that the first Spine Screen is level
and plumb, and at its final installation
location. Position the bottom screen
connector up to the bottom of the
vertical channel of the first Spine
Screen and firmly press it in, oriented
as shown (Figure 4 & Detail G).
3. Position the second Spine Screen
in-line against the first Spine Screen,
which has been adjusted level
and plumb. Level and plumb the
second screen to the first screen by
twisting the height-adjustable glides
clockwise or counter-clockwise until
the frame’s vertical edges are aligned.
Connect the screens together by
holding the first Spine Screen in
place while pressing firmly on the
second, into the first so the screen
connector in the first engages the
second screen (Figure 4 & Detail H).
4. Repeat the process in steps 2 & 3 to
add, level, plumb and connect the
remaining change-of-height screens
in the row. If the remaining screens
to be connected are the same height,
go now to “Leveling & Connecting
Spine Screens” instructions on
page 6, step 4.
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Figure 5
Spine Screen
10-wire
duplex
receptacle
10-wire
jumper
10-wire
rigid wireway
10-wire
duplex
receptacle
10-wire
duplex
receptacle
10-wire
duplex
receptacle
10-wire
jumper
Spine Screen
Detail I
10-wire
rigid wireway
mounting
plate
10-wire duplex
receptacle
Detail J
inner socket
of 10-wire
rigid wireway
10-wire duplex
receptacle
Detail K
wedges on
receptacle
catch
clip
10-wire duplex
receptacle
Electrical Installation - Overview
Important: Assembly of all frame
components must be completed,
with screen frames properly leveled
and mechanically secured to each
Duplex Receptacle Installation
Note: Duplex receptacles for the
10-wire system are specified/
ordered separately. Six receptacles
are available for accessing one of
each of the six circuits of the 10-wire
system. They are designed with a
numeral on each (i.e. 1, 2, 3, 4, 5, &
6). Circuits 4, 5 and 6 have triangles
to identify them as isolated circuits.
To install the receptacles, follow the
steps below.
WARNING: Assembly of all
mechanical components must
be completed before making any
electrical connections. All electrically
connected furnishings must also be
mechanically connected.
1. Per the space-planning layout,
determine the correct location for
each numbered receptacle in the
system (Figure 5).
2. Position the duplex receptacle on
either end of the 10-wire rigid
wireway as shown, matching the
arrow at the “N” symbol to the same
orientation on both the receptacle
and the wireway (Figure 5).
3. Align the receptacle so the end is
in-line with the inner socket on
the rigid wireway and push the
receptacle back against the mounting
plate (Detail I).
4. Slide the receptacle to the side so
the end terminals slide into the rigid
wireway’s inner socket (Detail J).
5. Receptacle is properly seated when
the catch clip on the wireway is
snapped in between the wedges on
the receptacle (Detail K).
other prior to installation of electrical
components.
Connection to the building power
supply may be made ONLY after all
screen wiring has been completed.
Building connections must be made
by a licensed electrician, following
local codes at the building site.
Note: Each circuit must be
individually protected with a
120-volt, 20-amp circuit breaker
device which will provide disconnect
and overload protection.
Prior to beginning electrical
component installation, read and
understand the following electrical
installation section and be familiar
with the electrical components and
all power infeed locations required.
Note: Each powered Spine Screen
has two 10-wire rigid wireways that
are pre-mounted in the base raceway
at the factory.
Note: Spine Screen electrical is
“in-line” only and does not turn
corners. Spine Screens cannot pass
power to Flex Screens.
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Screen-to-Screen 10-Wire Jumper
Installation
Note: Screen-to-screen jumpers
pass power between the pre-mounted
10-wire rigid wireways, through
the pass-through ankles, from one
screen to another. Screen-to-screen
jumpers are 173/4” long.
1. At the location specified for a
screen-to-screen jumper, route the
jumper through the pass-through
ankles, then plug the ends into each
rigid wireway (Figure 6 & Detail L).
Figure 6
Spine Screen
10-wire
jumper
10-wire
jumper
Spine Screen
screen-to-screen
10-wire jumper
pass-through
ankles
Detail L
Spine Screen
screen-to-screen
10-wire jumper
pass-through
ankles
10-wire
rigid wireway
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Figure 7
pass-through
ankles
pass-through
screen-to-screen
10-wire jumper
10-wire
rigid wireway
Spine Screen
(powered)
Spine Screen
(non-powered)
Spine Screen
(powered)
pass-through
ankles
Detail M
Spine Screen
(powered)
pass-through
screen-to-screen
10-wire jumper
pass-through
ankles
10-wire
rigid wireway
Spine Screen
(non-powered)
Pass-Through Screen-to-Screen
10-Wire Jumper Installation
Note: Pass-through screen-to-
screen jumpers pass power from one
powered Spine Screen through an
unpowered Spine Screen to another
powered Spine Screen. Pass-through
screen-to-screen jumpers length
are equal to the length of the
non-powered Spine Screen plus an
additional 173/4”.
1. At the location specified for a
pass-through screen-to-screen
jumper, route the jumper through the
pass-through ankles at each end of
the non-powered screen, then plug
the ends into each rigid wireway of
the powered Spine Screens (Figure 7
& Detail M).
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Top Power Infeed
(End-of-Run) Installation
Note: If the Spine Screen System
is to be installed with New York
City electrical, reference the Tattoo
Screen System - New York City
Electrical Assembly Instructions
(KI-AI-000045), and proceed to the
"New York City Infeed Electrical Box"
instructions on page 4.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
1. Per the space-planning layout,
determine the location for top power
infeed. Make sure the screen to
receive top power infeed is at its final
location, and is plumb and level.
2. At the ceiling, directly above the
location where the end-of-run top
infeed power pole will connect to
the Spine Screen end, drop a plumb
line from the ceiling, down to one
top, end corner of the Spine Screen,
then mark that location at the ceiling.
At the mark on the ceiling, carefully
mark and cut a rectangular hole
through the ceiling at 33/8 x 3”, as
illustrated for the power pole to go
through at a later step (Figure 8).
3. Measure from the ceiling, down
to the floor at the end of the
Spine Screen, then add 4” to that
measurement for required power
pole length. Take the top infeed
power pole in hand and transfer
that measurement to the top of the
pole, then squarely cut the top of the
power pole off to that measurement
(Figure 8).
Note: If a power pole extension
is needed for the top infeed power
pole to reach the ceiling, it must be
installed before installing the screen
connectors. Reference “Power Pole
Extension Installation” instructions
on page 19, then return to step 4 on
this page.
4. The screen connector comes with
eight molding clips installed (shown
uninstalled, Figure 8), four on each
side. Position the screen connector
up against the vertical frame channel
of the Spine Screen, with clips
oriented as shown. Using a firm
hand, press at the molding clips, on
the screen connector one at a time
to seat them into the vertical frame
channel at the end of the Spine
Screen (Figure 8 & Detail N).
5. Position the end-of-run top infeed
power pole, with the side opening
to the desired side of the screen,
and orient the top, cut end facing
upward. Route the top of the power
pole carefully up through the cut-out
in the ceiling while pressing the side
toward the screen connector/clips
in the vertical frame channel of the
screen. Let the bottom of the power
pole rest on the ground, then press
forcefully from inside the power pole
at the side, to engage all molding
clips of the screen connector into
the vertical channel of the top infeed
power pole (Figure 8 & Detail N).
Figure 8
Spine
Screen
screen
connector
ceiling
cutout
top infeed
power pole
(end-of-run)
molding
clips
vertical
power pole
channel
screen
connector
molding clip
(factory installed)
Spine
Screen
vertical
frame
channel
top infeed
power pole
(end-of-run)
Detail N
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
6. Determine the length of the inner
vertical trim by measuring the
distance from the ceiling to the top
of the Spine Screen frame. Next,
determine the length of the outer
vertical trim by measuring from
the ceiling, down to the floor at the
outer trim location. Then, squarely
cut the inner and outer vertical trim
section to the measured lengths
above (Figure 9).
7. On the rib side of the inner and
outer vertical trim, space molding
clips evenly apart and press them
onto the ribs of the vertical trim as
illustrated (Figure 9 & Detail O).
8. Position the inner and outer vertical
trim with molding clips up against
the appropriate side of the top
infeed power pole channel. Using
a firm hand, press the trim at the
molding clip locations to snap into
the power pole channel (Figure 9 &
Detail O).
9. Place the 10-wire top infeed
conduit inside the power pole and
route the plug end of the infeed
down through the pass-through
ankle and plug it into the end of the
10-wire rigid wireway (Figure 9).
10. Push the 10-wire end of the
power infeed up through the top
of the power pole and into the
above-ceiling area for later
connection to the source power (by
a certified electrician) (Figure 9).
11. Determine the length of the
top infeed power pole cover by
measuring the distance from the
ceiling to the floor at the side of the
infeed power pole. Cut the cover
square to the marked length
(Figure 9).
12. On the rib side of the power pole
cover, space molding clips evenly
apart and press them onto both ribs
on the cover as illustrated
(Figure 9 & Detail P).
13. Position the power pole cover
with molding clips up against the
opening side of the end-of-run
top infeed power pole. Using a
firm hand, press the cover at the
molding clip locations to snap into
power pole cover channel
(Figure 9 & Detail P).
Figure 9
Spine
Screen
10-wire top
power infeed
exposed
10-wires
top infeed
power pole
(end-of-run)
inner
vertical trim
power pole
cover
10-wire
rigid wireway
outer
vertical trim
pass-through
ankle
molding
clip
molding
clips
molding
clip
Detail O
vertical
power pole
channel
outer
power pole
vertical trim
molding
clip
Detail P
power pole
cover
power pole
cover
channel
molding
clips
power pole
cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Top Power Infeed
(In-Line) Installation
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for top power
infeed. Make sure that the screens
to receive top power infeed are near
their final location, and are plumb
and level.
2. At the ceiling, directly above the
location where the in-line top infeed
power pole will connect between two
Spine Screen ends, drop a plumb
line from the ceiling, down to one
top, end corner of the Spine Screen,
then mark that location at the ceiling.
At the mark on the ceiling, carefully
mark and cut a rectangular hole
through the ceiling at 33/8 x 3”, as
illustrated for the power pole to go
through at a later step (Figure 10).
3. Measure from the ceiling, down
to the floor at the end of the
Spine Screen, then add 4” to that
measurement for required power
pole length. Take the top infeed
power pole in hand and transfer that
measurement to the top of the power
pole, then squarely cut the top of the
power pole off to that measurement
(Figure 10).
Note: If a power pole extension
is needed for the top infeed power
pole to reach the ceiling, it must be
installed before installing the screen
connectors. Reference “Power Pole
Extension Installation” instructions
on page 19, then return to step 4 on
this page.
Spine
Screen
(#1)
Spine
Screen
(#2)
top infeed
power pole
(in-line)
vertical
power pole
channel
screen
connector
vertical
frame
channel
molding
clip
molding
clip
screen
connector
Figure 10
ceiling
cutout
4. The two required screen connectors
come with eight molding clips
installed (shown uninstalled,
Figure 10), four on each side.
At each Spine Screen end, as
illustrated, position the screen
connector up against the vertical
frame channel of the Spine Screen,
with clips oriented as shown. Using
a firm hand, press at the molding
clips, on the screen connector one at
a time to seat them into the vertical
frame channel at the end of the Spine
Screen (Figure 10 & Detail Q).
5. Position the in-line top infeed power
pole, with the side opening to the
desired side of the screen, and orient
the top, cut end facing upward. Route
the top of the power pole carefully
up through the cut-out in the ceiling
while pressing the side toward the
screen connector/clips in the vertical
frame channel of Spine Screen #1.
Let the bottom of the power pole rest
on the ground, then press forcefully
from inside the power pole, to
engage the screen connector/clips
of Spine Screen #1 into the channel
of the top infeed power pole. Next,
move the Spine Screen #2 over to
align its installed screen connector/
clips with the appropriate power pole
channel. Level and plumb Spine
Screen #2 to #1 by twisting the
height-adjustable glides clockwise or
counter-clockwise until the frame’s
vertical edges are aligned and tops of
screens are at the same height. Press
Spine Screen #2 screen connector/
clips into the power pole channel
to engage such that both Spine
Screens are snapped into the in-line
top infeed power pole (Figure 10 &
Detail Q).
screen
connector
molding clip
(factory installed)
Spine
Screen
vertical
frame
channel
vertical
power pole
channel
top infeed
power pole
(in-line)
Detail Q
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
6. Determine the length of both
vertical trim by measuring the
distance from the ceiling to the top
of the Spine Screen frame. Cut the
vertical trim to the marked lengths
(Figure 11).
7. On the rib side of the vertical trim,
space molding clips evenly apart
and press them onto the ribs of the
vertical trim as illustrated
(Figure 11 & Detail R).
8. Place the 10-wire top infeed
conduit inside the power pole and
route the plug end of the infeed
down through the pass-through
ankle and plug it into the end of the
10-wire rigid wireway (Figure 11).
9. Push the 10-wire end of the
power infeed up and through the
top of the power pole and into
the above-ceiling area for later
connection to the source power (by
a certified electrician)(Figure 11).
10. Determine the length of the
top infeed power pole cover by
measuring the distance from the
ceiling to the floor at the side of the
infeed power pole. Cut the cover
square to the marked length
(Figure 11).
11. On the rib side of the power pole
cover, space molding clips evenly
apart and press them onto both ribs
on the cover (Figure 11 & Detail S).
12. Position the power pole cover
with molding clips up against the
opening side of the end-of-run
top infeed power pole. Using a
firm hand, press on the trim at the
molding clip locations to snap
into the power pole cover channel
(Figure 11 & Detail S).
13. Reference “Leveling and
Connecting Spine Screens”
instructions on page 6 to connect
remaining screens.
screen-to-screen
10-wire jumper
(21 / ”)
1
4
power
pole cover
vertical
trim
vertical
trim
10-wire top
power infeed
exposed
10-wires
top infeed
power pole
(in-line)
pass-through
ankles
Spine
Screen
Spine
Screen
molding
clip
molding
clips
Figure 11
Detail R
outer
vertical
trim
molding
clip
vertical
power pole
channel
Detail S
power pole
cover
power pole
cover
channel
molding
clip
power pole
cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Spine
Screen
(#1)
Spine
Screen
(#2)
top infeed
power pole
(in-line)
vertical
power pole
channel
screen
connector
molding
clip
ceiling
cutout
Flex
Screen
bridge
foot
adjustable
glide foot
bottom
backside
“tongue”
Figure 12
screen
connector
molding clip
(factory installed)
Spine
Screen
(#1)
vertical
frame
channel
vertical
power pole
channel
top infeed
power pole
(in-line)
Detail T
10-Wire Top Power Infeed
(In-Line) Installation with Flex
Screen Intersection
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for top power
infeed. Make sure that the screens
to receive top power infeed are near
their final location, and are plumb
and level.
2. At the ceiling, directly above the
location where the in-line top infeed
power pole will connect between two
Spine Screen ends, drop a plumb
line from the ceiling, down to one
top, end corner of the Spine Screen,
then mark that location at the ceiling.
At the mark on the ceiling, carefully
mark and cut a rectangular hole
through the ceiling at 33/8 x 3”, as
illustrated for the power pole to go
through at a later step (Figure 12).
3. Measure from the ceiling, down to the
floor at the end of the Spine Screen,
then add 4” to that measurement for
required power pole length. Take the
top infeed power pole in hand and
transfer that measurement to the top
of the power pole, then squarely cut
the top of the power pole off to that
measurement (Figure 12).
Note: If a power pole extension
is needed for the top infeed power
pole to reach the ceiling, it must be
installed before installing the screen
connectors. Reference “Power Pole
Extension Installation” instructions
on page 19, then return to step 4 on
this page.
4. The two required screen connectors
come with eight molding clips
installed (shown uninstalled,
Figure 12), four on each side. At
Spine Screen #1's end, as illustrated,
position the screen connector up
against the vertical frame channel of
Spine Screen #1, with clips oriented
as shown. Using a firm hand, press
at the molding clips, on the screen
connector one at a time to seat them
into the vertical frame channel at the
end of Spine Screen #1 (Figure 12 &
Detail T).
5. Position the in-line top infeed power
pole as illustrated with the bottom
backside "tongue" facing at the
end of the adjoining Flex Screen to
install, and orient the top, cut end
facing upward. Route the top of the
power pole carefully up through the
cut-out in the ceiling while pressing
the side toward the screen connector/
clips in the vertical frame channel of
Spine Screen #1. Let the bottom of
the power pole rest on the ground,
then press forcefully from inside the
power pole, to engage the screen
connector/clips of Spine Screen #1
into the channel of the top infeed
power pole.
6. Carefully lift and arrange the Flex
Screen foot under the perpendicular
Spine Screen foot, aligning the Flex
Screen against the top infeed power
pole backside during the process
(Figure 12).
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Wide Screens - Spine Screen 10-Wire Power
Assembly Instructions
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
7. Carefully lift and arrange Spine
Screen #2 so that the adjustable foot
is over the foot of the Flex Screen
(Detail U). Move Spine Screen #2
over to align its installed screen
connector/clips with the appropriate
power pole channel. Level and plumb
Spine Screen #2 to #1 by twisting the
height-adjustable glides clockwise or
counter-clockwise until the frame’s
vertical edges are aligned and tops of
screens are at the same height. Press
Spine Screen #2 screen connector/
clips into the power pole channel
to engage such that both Spine
Screens are snapped into the in-line
top infeed power pole (Figure 13 &
Detail V).
Spine
Screen
(#1)
Spine
Screen
(#2)
top infeed
power pole
(in-line)
vertical
power pole
channel
screen
connector
molding
clip
Flex
Screen
bridge
foot
adjustable
glide foot
Figure 13
screen
connector
molding clip
(factory installed)
Spine
Screen
vertical
frame
channel
vertical
power pole
channel
top infeed
power pole
(in-line)
Detail V
Detail U - Spine Screen 3-Way
Intersection with Flex Screen
(adjustable feet over bridge foot)
bridge
foot
adjustable
glide feet
Flex
Screen
Spine
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Top Power Infeed
(In-Line) Installation with Flex
Screen Intersection (cont.)
Note: Each powered Spine Screen
has two 10-wire rigid wireways
that are pre-mounted in the base
raceway at the factory.
Note: Spine Screen electrical is
“in-line” only and does not turn
corners. Spine Screens cannot pass
power to Flex Screens.
8. Determine the length of both
vertical trim by measuring the
distance from the ceiling to the top
of the Spine Screen frame. Cut the
vertical trim to the marked lengths
(Figure 14).
9. On the rib side of the vertical trim,
space molding clips evenly apart
and press them onto the ribs of the
vertical trim as illustrated
(Figure 14 & Detail W).
10. Place the 10-wire top infeed
conduit inside the power pole and
route the plug end of the infeed
down through the pass-through
ankle and plug it into the end of the
10-wire rigid wireway (Figure 14).
11. Push the 10-wire end of the
power infeed up and through the
top of the power pole and into
the above-ceiling area for later
connection to the source power (by
a certified electrician)(Figure 14).
12. Determine the length of the
top infeed power pole cover by
measuring the distance from the
ceiling to the floor at the side of the
infeed power pole. Cut the cover
square to the marked length
(Figure 14).
13. On the rib side of the power pole
cover, space molding clips evenly
apart and press them onto both ribs
on the cover (Figure 14 & Detail X).
14. Position the power pole cover
with molding clips up against the
opening side of the end-of-run
top infeed power pole. Using a
firm hand, press on the trim at the
molding clip locations to snap
into the power pole cover channel
(Figure 14 & Detail X).
15. Reference “Leveling and
Connecting Spine Screens”
instructions on page 6 to connect
remaining screens.
screen-to-screen
10-wire jumper
(21 / ”)
1
4
power
pole cover
vertical
trim
vertical
trim
10-wire top
power infeed
exposed
10-wires
top infeed
power pole
(in-line)
pass-through
ankles
Spine
Screen
(#2)
Spine
Screen
(#1)
molding
clip
molding
clips
Flex
Screen
10-wire
rigid wireway
Figure 14
Detail W
outer
vertical
trim
molding
clip
vertical
power pole
channel
Detail X
power pole
cover
power pole
cover
channel
molding
clip
power pole
cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Wide Screens - Spine Screen 10-Wire Power
Assembly Instructions
Power Pole Extension Installation
Note: The power pole extension is
specified for ceilings higher than
10’, and must be added to the top
infeed power pole prior to installing
the pole to the Spine Screen(s). The
Spine Screen(s) to receive the power
pole with extension must be at their
final installation location.
1. Assure that the Spine Screen(s) to
receive the power pole with extension
are at their final installation location,
the hole is cut in the ceiling as
specified earlier (pages 12, 14 & 16),
then measure from the ceiling to the
floor at the end of a screen which
will receive the extended pole. The
top infeed power pole is 122” long,
so subtract 122” from the floor to
ceiling measurement, then add 4” for
the length to cut the extension pole
to. Take the power pole extension in
hand, transfer the required length
measurement to it and squarely cut
the extension pole to size such that
it can project 4” above ceiling height
when installed.
2. As illustrated, align the open side
of the power pole extension bracket
with the open side at the top of the
top infeed power pole, and slide the
extension bracket into the power
pole, aligning the mounting holes
of both. Insert four #10-24 x 1/2”
Phillips flat head screws through
the power pole and bracket at four
mounting locations, then add #10-24
lock nuts and tighten (Figure 15 &
Detail Y).
3. Orient the cut-off end of the pole
extension away from the power
pole’s installed extension bracket.
With the opened side of the power
pole extension facing in the same
direction as the installed power pole
extension bracket opening, slide
the extension pole onto the power
pole extension bracket, aligning the
mounting holes of both (Figure 16 &
Detail Z).
4. Insert four #10-24 x 1/2” Phillips
flat head screws through the power
pole extension and bracket at four
mounting locations, then add #10-24
lock nuts and tighten (Figure 16 &
Detail Z).
Reference “10-Wire Top Power
Infeed (End-of-Run) Installation”
instructions on page 12, step 4,
“10-Wire Top Power Infeed (In-Line)
Installation” instructions on
page 14, step 4, or “10-Wire Top
Power Infeed (In-Line) Installation
with Flex Screen Intersection”
instructions on page 16, step 4
to finish top infeed power pole
installation.
Figure 15
power pole
extension
bracket
top infeed
power pole
Figure 16
power pole
extension
bracket
top infeed
power pole
power pole
extension
Detail Y
#10-24
lock nuts
#10-24 x / ”
Phillips flat
head screw
1
2
power pole
extension
bracket
#10-24 x / ”
Phillips flat
head screw
1
2
vertical
power pole
channel
Detail Z
#10-24
lock nuts
#10-24 x / ”
Phillips flat
head screw
1
2
vertical power
pole channel
power pole
extension
top infeed
power pole
power pole
extension
bracket
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Base Power Infeed
(End-of-Run) Installation
Important: If the Spine Screen
System is to be installed with New
York City electrical, reference the
Tattoo Screen System - New York
City Electrical Assembly Instructions
(KI-AI-000045), and proceed to the
"New York City Infeed Electrical Box"
instructions on page 4.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
1. Per the space-planning layout,
determine the location for base
power infeed. Make sure that screen
to receive base power infeed is in
its final location, and is plumb and
level.
2. At the bottom of the screen frame
which will receive base power infeed,
route the plug end of the 10-wire
base infeed conduit through the
pass-through ankle and plug it into
the end of the 10-wire rigid wireway
(Figure 17).
3. On the rib side of the end-of-run
base infeed trim, space molding clips
evenly apart and press them onto the
ribs of the trim as illustrated
(Figure 18).
4. Position the end-of-run base infeed
trim with molding clips up against
the vertical frame channel. Align the
top of the trim with the bottom of the
horizontal frame and position the
10-wire base infeed through the
U-shaped cutout. Using a firm hand,
press to snap molding clips of the
end-of-run base infeed trim into the
vertical frame channel (Figure 18).
Spine
Screen
vertical
frame
channel
vertical
frame
pass-through
ankle
10-wire base
power infeed
exposed
10-wires
Figure 17
Figure 18
Spine
Screen
10-wire
base infeed
vertical
frame
channel
vertical
frame
end-of-run
base infeed
trim
molding
clip
horizontal
frame
end-of-run
corner
cap
#10-24 x / ”
Torx screws
3
8
5. Place the end-of-run corner cap into
the notch formed on the top corner
of the horizontal frame. Align the
mounting holes on the horizontal
frame with the mounting holes on
the corner cap and secure with two
#10-24 x 3/8” Torx screws
(Figure 18).
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Detail AA
10-wire
rigid wireway
mounting
plate
base infeed
adapter receptacle
Detail BB
inner socket
of 10-wire
rigid wireway
base infeed
adapter receptacle
Detail CC
wedges on
adapter
catch
clip
base infeed
adapter receptacle
Spine
Screen
base infeed
adapter receptacle
10-wire
rigid wireway
mounting
plate
Figure 19
Spine
Screen
base infeed
adapter
receptacle
180°
base
raceway
trim
base raceway
power infeed
base power
infeed shroud
shroud
screw
lock bar
lock
bar
Figure 20
base
trim lip
Detail DD
base
raceway
trim
bottom
wireway
channel
base infeed
adapter
receptacle
base raceway
power infeed
base power
infeed shroud
lock
bar
shroud
screw
Detail EE
Base Raceway Power Infeed
Installation
1. Position the base infeed adapter
receptacle on the end of the 10-wire
rigid wireway where the base power
infeed is received, matching the
arrow at the “N” symbol facing up
(Figure 19 & Detail AA).
2. Align the adapter so the end is
in-line with the inner socket on the
rigid wireway and push the adapter
back against the mounting plate
(Detail AA).
3. Slide the adapter receptacle to
the side and snap it into the rigid
wireway’s inner socket (Detail BB).
4. Adapter is properly seated when the
catch clip on the wireway is snapped
in between the wedges on the
receptacle (Detail CC).
5. Install the base raceway trim by
engaging the base trim lip with the
bottom wireway channel (Detail DD).
6. Pull up the lock bar on the plug end
of the base raceway power infeed.
The base infeed can be rotated 180°
and installed in one of two directions.
Orient the lock bar to be up, then
press the base raceway power infeed
to the adapter receptacle in the
desired direction. Press down to
snap and secure the lock bar onto
the base infeed adapter receptacle
on the power infeed, then place the
base infeed shroud over the infeed
and secure with the shroud screw
provided (Figure 20 & Detail EE).
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Base Power Infeed
Spacer (End-of-Run) Installation
Important: If the Spine Screen
System is to be installed with New
York City electrical, reference the
Tattoo Screen System - New York
City Electrical Assembly Instructions
(KI-AI-000045), and proceed to the
"New York City Infeed Electrical Box"
instructions on page 4.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
1. Per the space-planning layout,
determine the location for base
power infeed. Make sure that screen
to receive base power infeed is in
its final location, and is plumb and
level.
2. At the bottom of the screen frame
which will receive base power infeed,
route the plug end of the 10-wire
base infeed conduit through the
pass-through ankle and plug it into
the end of the 10-wire rigid wireway
(Figure 21).
3. The screen connector comes with
eight molding clips installed (shown
uninstalled, Figure 23), four on each
side. Position the screen connector
up against the vertical frame channel
of the Spine Screen, with clips
oriented as shown. Using a firm
hand, press at the mounting clips
on the screen connector, one at a
time to seat them into the vertical
frame channel at the end of the Spine
Screen (Figure 22 & Detail FF).
4. Position the base infeed spacer
against the vertical frame, with the
side opening as desired, and the
top facing upward. If the base infeed
spacer top is higher than the top of
the Spine Screen's horizontal frame,
the spacer is too tall at the top and
must be squarely cut off from the
bottom. Cut required amount off the
bottom, then press the side of the
base infeed spacer with the molding
clips in the vertical frame channel on
the Spine Screen taking care to align
the top of the base infeed spacer with
the top of the screen's horizontal
frame. Press forcefully from inside
the spacer at the side, to engage the
screen connector into the channel of
the base infeed spacer (Figure 22 &
Detail FF).
Note: Two different top caps are
available for Tattoo Screen spacers
and are labeled so on the bottom
of each top cap. An “E” or “I”
is displayed on each top cap to
represent if the cap is for end-of-run
or in-line. As labeled, the top caps
are designed to install to a specific
spacer. Take care and follow the
directions below when installing
the top cap. If proper top cap is
not installed to the proper spacer,
the flat aluminum top cap will not
fit correctly, extending too far and
disassembly and reassembly will be
required.
Spine
Screen
vertical
frame
pass-through
ankle
10-wire base
power infeed
exposed
10-wires
Figure 21
Figure 22
Spine
Screen
screen
connector
molding
clip
#10-24 X / ”
Phillips flat
head screw
1
2
base infeed
top cap
(end-of-run)
base
infeed spacer
(end-of-run)
vertical
frame
channel
vertical
frame
Detail FF
Spine
Screen
screen
connector
molding clip
(factory installed)
#10-24 x / ”
Phillips flat
head screw
1
2
base
infeed spacer
(end-of-run)
vertical
frame
channel
base infeed top cap
(end-of-run)
5. Confirm the base infeed top cap is
labelled “E” on the underside for
end-of-run. Place the base infeed
top cap onto the base infeed spacer.
Align the mounting hole on the side
of the top cap with the mounting
hole in the spacer cover channel and
secure with a #10-24 x 1/2” Phillips
flat head screw. The base infeed
top cap will rest flush with the flat
aluminum top cap installed in a later
step (Figure 22 & Detail FF).
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
6. On the rib side of the base infeed
trim, space molding clips evenly
apart and press them onto the ribs of
the trim (Figure 23 & Detail GG).
7. Position the base infeed trim with
molding clips up against the base
infeed spacer with the 10-wire infeed
routed through the opening at the
bottom of the infeed trim. Using a
firm hand, press to snap molding
clips of the base infeed trim into the
vertical spacer channel (Figure 23 &
Detail GG).
8. On the rib side of the base infeed
spacer cover, space molding clips
evenly apart and press them onto
both ribs on the cover (Figure 23 &
Detail HH).
9. Position the base infeed space cover
with molding clips up against the
base infeed spacer. Using a firm
hand, press to snap molding clips
of the spacer cover into the spacer
cover channel (Figure 23 &
Detail HH).
Figure 23
Spine
Screen
base infeed trim
(end-of-run)
molding
clip
vertical
spacer
channel
space cover
channel
spacer
cover
10-wire base
power infeed
base
infeed spacer
(end-of-run)
Detail GG
vertical
spacer
channel
molding
clip
base infeed
trim
Detail HH
spacer
cover
molding
clip
spacer cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Base Power Infeed
Spacer (In-Line) Installation
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for base
infeed spacer. Make sure that the
screens to receive the base infeed
spacer are near their final location,
and are plumb and level.
2. The two required screen connectors
come with eight molding clips
installed to each (shown uninstalled,
Figure 24), four on each side.
At each Spine Screen end, as
illustrated, position the screen
connector up against the vertical
frame channel of the Spine Screen,
with clips oriented as shown. Using
a firm hand, press at the mounting
clips on the screen connector, one at
a time to seat them into the vertical
frame channel at the end of the Spine
Screen (Figure 24 & Detail II).
3. Position the base infeed spacer
against the vertical frame, with the
side opening as desired, and the
top facing upward. If the base infeed
spacer top is higher than the top of
the Spine Screen's horizontal frame,
the spacer is too tall at the top and
must be squarely cut off from the
bottom. Cut required amount off the
bottom, then press the side of the
base infeed spacer with the molding
clips in the vertical frame channel on
the Spine Screen taking care to align
the top of the base infeed spacer with
the top of the screen's horizontal
frame. Press forcefully from inside
the spacer, to engage the screen
connector/clips of Spine Screen #1
into the channel of the base infeed
spacer. Next, move the Spine Screen
#2 over to align its installed screen
connector/clips with the appropriate
vertical spacer channel. Level and
plumb Spine Screen #2 to #1 by
twisting the height-adjustable glides
clockwise or counter-clockwise until
the frame’s vertical edges are aligned
and tops of screens are at the same
height. Press Spine Screen #2 into
the vertical spacer channel to engage
such that both Spine Screens are
snapped into the base infeed spacer
(Figure 24 & Detail II).
Note: Two different top caps are
available for Tattoo Screen spacers
and are labeled so on the bottom
of each top cap. An “E” or “I”
is displayed on each top cap to
represent if the cap is for end-of-run
or in-line. As labeled, the top caps
are designed to install to a specific
spacer. Take care and follow the
directions below when installing the
top cap. If top cap is not installed to
the proper spacer, the flat aluminum
top cap will not fit correctly,
extending too far and disassembly
and reassembly will be required.
4. Confirm the base infeed top cap
is labelled “I” on the underside for
inline. Place the base infeed top cap
onto the base infeed spacer. Align
the mounting hole on the side of the
top cap with the mounting hole in
the spacer cover channel and secure
with a #10-24 x 1/2” Phillips flat head
screw. The base infeed top cap will
rest flush with the flat aluminum top
cap installed in a later step
(Figure 24 & Detail II).
5. At the location specified for a
screen-to-screen jumper between the
base infeed spacer, route the jumper
through the pass-through ankles at
each end of the Spine Screen, then
plug the ends into each rigid wireway
of the powered Spine Screens
(Figure 24).
6. Route the 10-wire base power infeed
plug end of the infeed through the
pass-through ankle and plug it
into an open end of a 10-wire rigid
wireway (Figure 24).
Spine
Screen
(#1)
Spine
Screen
(#2)
base infeed
top cap
(in-line)
base infeed
spacer
(in-line)
screen
connector
vertical
frame
channel
molding
clip
molding
clip
#10-24 x / ”
Phillips flat
head screw
1
2
screen-to-screen
10-wire jumper
(21 / ”)
1
4
10-wire
rigid wireway
10-wire
rigid wireway
vertical
spacer
channel
10-wire base
power infeed
Figure 24
Detail II
Spine
Screen
screen
connector
molding clip
(factory installed)
#10-24 x / ”
Phillips flat
head screw
1
2
base
infeed spacer
(in-line)
vertical
frame
channel
base infeed
top cap (in-line)
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
7. On the rib side of the spacer cover,
space molding clips evenly apart and
press them onto the ribs of the cover
(Figure 25 & Detail JJ).
8. Position the spacer cover with
molding clips up against the spacer
cover channel with the 10-wire base
infeed routed through the opening at
the bottom of the spacer cover. Using
a firm hand, press on the spacer
cover at the molding clip locations to
snap molding clips into the spacer
cover channel (Figure 25 &
Detail JJ).
9. Reference “Leveling and Connecting
Spine Screens” instructions on
page 6 to connect remaining screens.
Spine
Screen
Spine
Screen
base infeed
spacer (in-line)
spacer
cover
spacer
cover
channel
molding
clip
10-wire base
power infeed
Figure 25
Detail JJ
spacer
cover
molding
clip
spacer cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Base Power Infeed
Spacer (In-Line) Installation with
Flex Screen Intersection
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for base
infeed spacer. Make sure that the
screens to receive the base infeed
spacer are near their final location,
and are plumb and level.
2. The two required screen connectors
come with eight molding clips
installed to each (shown uninstalled,
Figure 26), four on each side. At
Spine Screen #1's end, as illustrated,
position the screen connector up
against the vertical frame channel of
Spine Screen #1, with clips oriented
as shown. Using a firm hand, press
at the mounting clips on the screen
connector, one at a time to seat them
into the vertical frame channel at the
end of the Spine Screen #1
(Figure 26 & Detail KK).
3. Position the base infeed spacer as
illustrated with the bottom backside
"tongue" facing at the end of the
adjoining Flex Screen to install. If
the base infeed spacer top is higher
than the top of the Spine Screen #1's
horizontal frame, the spacer is too
tall at the top and must be squarely
cut off from the bottom. Cut required
amount off the bottom, then press
the side of the base infeed spacer
with the molding clips in the vertical
frame channel on Spine Screen #1
taking care to align the top of the
base infeed spacer with the top of
the screen's horizontal frame. Press
forcefully from inside the spacer, to
engage the screen connector/clips
of Spine Screen #1 into the channel
of the base infeed spacer into an
open end of a 10-wire rigid wireway
(Figure 26).
4. Carefully lift and arrange the Flex
Screen foot under the perpendicular
Spine Screen foot, aligning the
Flex Screen against the base infeed
spacer backside during the process
(Figure 26).
Figure 26
Spine
Screen
(#1)
Spine
Screen
(#2)
base infeed
spacer
(in-line)
screen
connector
molding
clip
vertical
spacer
channel
Flex
Screen
bridge
foot
adjustable
glide foot
bottom
backside
“tongue”
Detail KK
Spine
Screen
(#1)
screen
connector
molding clip
(factory installed)
base
infeed spacer
(in-line)
vertical
frame
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
5. Carefully lift and arrange Spine
Screen #2 so that the adjustable foot
is over the foot of the Flex Screen
(Detail MM). Move Spine Screen #2
over to align its installed screen
connector/clips with the appropriate
vertical spacer channel. Level and
plumb Spine Screen #2 to #1 by
twisting the height-adjustable glides
clockwise or counter-clockwise until
the frame’s vertical edges are aligned
and tops of screens are at the same
height. Press Spine Screen #2 screen
connector/clips into the vertical
spacer channel to engage such that
both Spine Screens are snapped into
the in-line base infeed spacer
(Figure 27 & Detail LL).
Spine
Screen
(#1)
Spine
Screen
(#2)
vertical
spacer
channel
screen
connector
molding
clip
Flex
Screen
bridge
foot
adjustable
glide foot
base infeed
spacer
(in-line)
Figure 27
Detail LL
Spine
Screen
(#2)
screen
connector
molding clip
(factory installed)
base
infeed spacer
(in-line)
vertical
frame
channel
Detail MM - Spine Screen 3-Way
Intersection with Flex Screen
(adjustable feet over bridge foot)
bridge
foot
adjustable
glide feet
Flex
Screen
Spine
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
10-Wire Base Power Infeed
Spacer (In-Line) Installation with
Flex Screen Intersection (cont.)
Note: Two different top caps are
available for Tattoo Screen spacers
and are labeled so on the bottom
of each top cap. An “E” or “I”
is displayed on each top cap to
represent if the cap is for end-of-run
or in-line. As labeled, the top caps
are designed to install to a specific
spacer. Take care and follow the
directions below when installing
the top cap. If proper top cap is
not installed to the proper spacer,
the flat aluminum top cap will not
fit correctly, extending too far and
disassembly and reassembly will be
required.
6. Confirm the base infeed top cap
is labelled “I” on the underside for
inline. Place the base infeed top cap
onto the base infeed spacer. Align
the mounting hole on the side of the
top cap with the mounting hole in
the spacer cover channel and secure
with a #10-24 x 1/2” Phillips flat head
screw. The base infeed top cap will
rest flush with the flat aluminum top
cap installed in a later step
(Figure 28 & Detail NN).
Note: Each powered Spine Screen
has two 10-wire rigid wireways that
are pre-mounted in the base raceway
at the factory.
Note: Spine Screen electrical is
“in-line” only and does not turn
corners. Spine Screens cannot pass
power to Flex Screens.
Spine
Screen
(#2)
Spine
Screen
(#1)
Flex
Screen
base infeed
top cap
(in-line)
base infeed
spacer
(in-line)
#10-24 x / ”
Phillips flat
head screw
1
2
Figure 28
Spine
Screen
(#2)
Spine
Screen
(#1)
#10-24 x / ”
Phillips flat
head screw
1
2
base
infeed spacer
(in-line)
base infeed
top cap
(in-line)
Detail NN
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen 10-Wire Power
Assembly Instructions
Spine
Screen
(#1)
Spine
Screen
(#2)
base infeed
spacer (in-line)
10-wire
rigid wireway
10-wire base
power infeed
screen-to-screen
10-wire jumper (21 / ”)
1
4
10-wire
rigid wireway
Flex
Screen
Figure 29
Spine
Screen
Spine
Screen
base infeed
spacer (in-line)
spacer
cover
spacer
cover
channel
molding
clip
10-wire base
power infeed
Flex
Screen
Figure 30
Detail OO
spacer
cover
molding
clip
spacer cover
channel
7. At the location specified for a
screen-to-screen jumper between
the base infeed spacer, route the
jumper through the pass-through
ankles at each end of the Spine
Screen, then plug the ends into
each rigid wireway of the powered
Spine Screens (Figure 29).
8. Route the 10-wire base power
infeed plug end of the infeed
through the pass-through ankle and
plug it into an open end of a
10-wire rigid wireway (Figure 29).
9. On the rib side of the spacer cover,
space molding clips evenly apart
and press them onto the ribs of the
cover (Figure 30 & Detail OO).
10. Position the spacer cover with
molding clips up against the spacer
cover channel with the 10-wire base
infeed routed through the opening
at the bottom of the spacer cover.
Using a firm hand, press on the
spacer cover at the molding clip
locations to snap molding clips into
the spacer cover channel (Figure 30
& Detail OO).
11. Reference “Leveling and
Connecting Spine Screens”
instructions on page 6 to connect
remaining screens.
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Hardwired Electrical
Assembly Instructions
Hardwired Electrical Base Power
Infeed Trim Installation
Note: City of Chicago requires the
use of hardwired electrical. Conduit,
wiring and receptacles are customer
supplied.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
Note: All screens must be
mechanically connected together,
with all connections appropriately
installed before adding power infeed,
or connecting infeed to power
source.
1. Per the space-planning layout,
determine the location for the
hardwired base power infeed. Make
sure that the screen to receive the
base power infeed is in its final
location, and is plumb and level.
2. On the rib side of the base infeed
vertical trim, space molding clips
evenly apart and press them onto the
ribs of the vertical trim as illustrated
(Figure 31).
3. Position the base infeed vertical
trim with molding clips up against
the vertical frame channel that will
receive hardwired base power infeed.
Align the top of the trim with the
bottom of the horizontal frame. Using
a firm hand, press along the vertical
trim at the molding clip locations
to snap clips into the vertical frame
channel (Figure 31).
4. Place the end-of-run corner cap into
the notch formed on the top corner
of the horizontal frame. Align the
mounting holes on the horizontal
frame with the mounting holes on the
corner cap and secure with two
#10-24 x 3/8” Torx screws
(Figure 31).
5. At the bottom of the screen frame
which will receive hardwired base
power infeed, follow all state and
local codes at the job site and install
conduit, wiring and receptacles per
space-planning layout.
6. Install the base raceway trim by
aligning the receptacles with the
openings in the base raceway trim,
then engage the base trim lip with the
bottom wireway channel (Figure 32
& Detail PP).
Spine
Screen
base infeed
vertical trim
molding
clip
vertical
frame
channel
vertical
frame
empty
junction box
Figure 31
end-of-run
corner
cap
#10-24 x / ”
Torx screws
3
8
Spine
Screen
pass-through
ankle
base infeed
vertical trim
base
raceway trim
(hardwired)
electrical-added
hardwired
Figure 32
base
trim lip
Detail PP
base
raceway
trim
bottom
wireway
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Data
Assembly Instructions
Data Installation
Note: Data cables must only be run
after all screens are mechanically
connected together, and after all
power has been installed.
Note: A 45 degree data mounting
plate is required due to limited
space in the base raceway channel.
Cables, terminations and 45 degree
data mounting plates are customer
supplied.
1. Per the space-planning layout,
determine data jack locations
required in base wireway channels.
A standard cutout for data plates
in base raceway trim is provided
(Figure 33).
2. Data cables must be routed and
placed underneath the 10-wire rigid
wireway, in the bottom wireway
channel.
3. Route data wires from their source
and along the bottom wireway
channel to the desired data jack
locations (Detail QQ).
4. Align the holes of the 45 degree data
mounting plate with the base raceway
trim holes and secure with the
screws provided. Make all data jack
connections per the manufacturer’s
specifications.
5. After all data connections have been
made, install the base raceway trim
by engaging the base trim lip with
the bottom wireway channel
(Detail RR).
base
raceway
trim
45 degree
data mounting
plate
data mounting
plate screws
data jack
connector
Figure 33
Detail QQ
base
raceway
trim
45 degree
data mounting
plate
data
mounting
plate screws
data jack
connector
Detail RR
base
raceway
trim
base
trim lip
bottom
wireway
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
End-of-Run Spacer Installation
1. Per the space-planning layout, locate
the end-of-run screen. Make sure
that screen is near its final location
and is plumb and level.
2. The screen connector comes with
eight molding clips installed (shown
uninstalled, Figure 36), four on each
side. Position the screen connector
up against the vertical frame channel
of the Spine Screen, with clips
oriented as shown. Using a firm
hand, press at the mounting clips
on the screen connector, one at a
time to seat them into the vertical
frame channel at the end of the Spine
Screen (Figure 34 & Detail SS).
3. Position the spacer against the
vertical frame, with the side opening
as desired, and the top facing
upward. If the spacer top is higher
than the top of the Spine Screen's
horizontal frame, the spacer is too
tall at the top and must be squarely
cut off from the bottom. Cut required
amount off the bottom, then press the
side of the spacer with the molding
clips in the vertical frame channel on
the Spine Screen taking care to align
the top of the spacer with the top of
the screen's horizontal frame. Press
forcefully from inside the spacer
at the side, to engage the screen
connector into the channel of the
spacer (Figure 34 & Detail SS).
Note: Two different top caps are
available for Tattoo Screen spacers
and are labeled so on the bottom
of each top cap. An “E” or “I”
is displayed on each top cap to
represent if the cap is for end-of-run
or in-line. As labeled, the top caps
are designed to install to a specific
spacer. Take care and follow the
directions below when installing
the top cap. If proper top cap is
not installed to the proper spacer,
the flat aluminum top cap will not
fit correctly, extending too far and
disassembly and reassembly will be
required.
4. Confirm the base infeed top cap is
labelled “E” on the underside for
end-of-run. Place the spacer top cap
onto the spacer. Align the mounting
hole on the side of the top cap with
the mounting hole in the spacer
cover channel and secure with a
#10-24 x 1/2” Phillips flat head screw.
The base infeed top cap will rest
flush with the flat aluminum top cap
installed in a later step (Figure 34 &
Detail SS).
5. On the rib side of the spacer trim,
space molding clips evenly apart and
press them onto the ribs of the trim
(Figure 35 & Detail TT).
6. Position the spacer trim with
molding clips up against the spacer.
Using a firm hand, press to snap
molding clips of the base infeed
trim into the vertical spacer channel
(Figure 35 & Detail TT).
7. On the rib side of the spacer cover,
space molding clips evenly apart
and press them onto both ribs on the
cover (Figure 35 & Detail UU).
8. Position the space cover with
molding clips up against the spacer.
Using a firm hand, press to snap
moling clips of the spacer cover into
the spacer cover channel (Figure 35
& Detail UU).
Spine
Screen
vertical
frame
screen
connector
molding
clip
#10-24 x / ”
Phillips flat
head screw
1
2
spacer
top cap
(end-of-run)
spacer
(end-of-run)
vertical
frame
channel
Figure 34
Detail SS
Spine
Screen
screen
connector
molding clip
(factory installed)
#10-24 x / ”
Phillips flat
head screw
1
2
spacer
(end-of-run)
vertical
frame
channel
spacer top cap
(end-of-run)
Figure 35
Spine
Screen
spacer trim
(end-of-run)
molding
clip
vertical
spacer
channel
space cover
channel
spacer
cover
spacer
(end-of-run)
Detail TT
vertical
spacer
channel
molding
clip
spacer
trim
Detail UU
molding
clip
spacer cover
channel
spacer
cover
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
In-Line Spacer Installation
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for in-line
spacer. Make sure that the screens to
receive the spacer are near their final
location, and are plumb and level.
2. The two required screen connectors
come with eight molding clips
installed to each (shown uninstalled,
Figure 36), four on each side.
At each Spine Screen end, as
illustrated, position the screen
connector up against the vertical
frame channel of the Spine Screen,
with clips oriented as shown. Using
a firm hand, press at the mounting
clips on the screen connector, one at
a time to seat them into the vertical
frame channel at the end of the Spine
Screen (Figure 36 & Detail WW).
3. Position the spacer against the
vertical frame, with the side opening
as desired, and the top facing
upward. If the base spacer top is
higher than the top of the Spine
Screen's horizontal frame, the spacer
is too tall at the top and must be
squarely cut off from the bottom.
Cut required amount off the bottom,
then press the side of the spacer
with the molding clips in the vertical
frame channel on the Spine Screen
taking care to align the top of the
base infeed spacer with the top of
the screen's horizontal frame. Press
forcefully from inside the spacer,
to engage the screen connector/
clips of Spine Screen #1 into the
channel of the base infeed spacer.
Next, move Spine Screen #2 over to
align its installed screen connector/
clips with the appropriate vertical
spacer channel. Level and plumb
Spine Screen #2 to #1 by twisting the
height-adjustable glides clockwise or
counter-clockwise until the frame’s
vertical edges are aligned and tops of
screens are at the same height. Press
Spine Screen #2 into the vertical
spacer channel to engage such that
both Spine Screens are snapped into
the spacer (Figure 36 & Detail WW).
4. Confirm the spacer top cap is
labelled “I” on the underside for
inline. Place the spacer top cap onto
the base spacer. Align the mounting
hole on the side of the top cap with
the mounting hole in the spacer
cover channel and secure with a
#10-24 x 1/2” Phillips flat head screw.
The spacer top cap will rest flush with
the flat aluminum top cap installed in
a later step (Figure 36 & Detail WW).
5. At the location specified for a
screen-to-screen jumper between
the spacer, route the jumper through
the pass-through ankles at each end
of the Spine Screen, then plug the
ends into each rigid wireway of the
powered Spine Screens (Figure 37).
6. On the rib side of the spacer cover,
space molding clips evenly apart and
press them onto the ribs of the cover
(Figure 37 & Detail VV).
7. Position the spacer cover with
molding clips up against the spacer
cover channel. Using a firm hand,
press on the spacer cover at the
molding clip locations to snap
molding clips into the spacer cover
channel (Figure 37 & Detail VV).
molding
clips
Spine
Screen
(#1)
Spine
Screen
(#2)
spacer
top cap
(in-line)
spacer
(in-line)
spine screen
connector
vertical
frame
channel
molding
clips
#10-24 x / ”
Phillips flat
head screw
1
2
vertical
spacer
channel
Figure 36
Spine
Screen
Spine
Screen
spacer
(in-line)
spacer
cover
spacer
cover
channel
molding
clip
screen-to-screen
10-wire jumper
(21 / ”)
1
4
Figure 37
Detail WW
Spine
Screen
screen
connector
molding clip
(factory installed)
#10-24 x / ”
Phillips flat
head screw
1
2
spacer
(in-line)
vertical
frame
channel
spacer top
cap (in-line)
Detail VV
spacer
cover
molding
clip
spacer cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
In-Line Spacer Installation with
Flex Screen Intersection
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
1. Per the space-planning layout,
determine the location for in-line
spacer. Make sure that the screens to
receive the spacer are near their final
location, and are plumb and level.
2. The two required screen connectors
come with eight molding clips
installed to each (shown uninstalled,
Figure 38), four on each side. At
Spine Screen #1's end, as illustrated,
position the screen connector up
against the vertical frame channel of
Spine Screen #1, with clips oriented
as shown. Using a firm hand, press
at the mounting clips on the screen
connector, one at a time to seat them
into the vertical frame channel at the
end of the Spine Screen #1
(Figure 38 & Detail XX).
3. Position the spacer as illustrated with
the bottom backside "tongue" facing
the end of the adjoining Flex Screen
to install. If the spacer top is higher
than the top of the Spine Screen #1's
horizontal frame, the spacer is too
tall at the top and must be squarely
cut off from the bottom. Cut required
amount off the bottom, then press the
side of the spacer with the molding
clips in the vertical frame channel on
Spine Screen #1 taking care to align
the top of the spacer with the top of
the screen's horizontal frame. Press
forcefully from inside the spacer, to
engage the screen connector/clips of
Spine Screen #1 into the channel of
the spacer into an open end of a
10-wire rigid wireway (Figure 38).
4. Carefully lift and arrange the Flex
Screen foot under the perpendicular
Spine Screen foot, aligning the Flex
Screen against the spacer during the
process (Figure 38).
Figure 38
Spine
Screen
(#1)
Spine
Screen
(#2)
spacer
(in-line)
screen
connector
molding
clip
vertical
spacer
channel
Flex
Screen
bridge
foot
adjustable
glide foot
bottom
backside
“tongue”
Detail XX
Spine
Screen
(#1)
screen
connector
molding clip
(factory installed)
spacer
(in-line)
vertical
frame
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
5. Carefully lift and arrange Spine
Screen #2 so that the adjustable foot
is over the foot of the Flex Screen
(Detail ZZ). Move Spine Screen #2
over to align its installed screen
connector/clips with the appropriate
power pole channel. Level and plumb
Spine Screen #2 to #1 by twisting the
height-adjustable glides clockwise or
counter-clockwise until the frame’s
vertical edges are aligned and tops of
screens are at the same height. Press
Spine Screen #2 screen connector/
clips into the vertical spacer channel
to engage such that both Spine
Screens are snapped into the in-line
spacer (Figure 39 & Detail YY).
Spine
Screen
(#1)
Spine
Screen
(#2)
vertical
spacer
channel
screen
connector
molding
clip
Flex
Screen
bridge
foot
adjustable
glide foot
spacer
(in-line)
Figure 39
Detail YY
Spine
Screen
(#2)
screen
connector
molding clip
(factory installed)
spacer
(in-line)
vertical
frame
channel
Detail ZZ - Spine Screen 3-Way
Intersection with Flex Screen
(adjustable feet over bridge foot)
bridge
foot
adjustable
glide feet
Flex
Screen
Spine
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
In-Line Spacer Installation with
Flex Screen Intersection (cont.)
Note: Two different top caps are
available for Tattoo Screen spacers
and are labeled so on the bottom
of each top cap. An “E” or “I”
is displayed on each top cap to
represent if the cap is for end-of-run
or in-line. As labeled, the top caps
are designed to install to a specific
spacer. Take care and follow the
directions below when installing the
top cap. If top cap is not installed to
the proper spacer, the flat aluminum
top cap will not fit correctly,
extending too far and disassembly
and reassembly will be required.
6. Confirm the spacer top cap is
labelled “I” on the underside for
inline. Place the top cap onto the
spacer. Align the mounting hole
on the side of the top cap with the
mounting hole in the spacer
cover channel and secure with a
#10-24 x 1/2” Phillips flat head
screw. The spacer top cap will rest
flush with the flat aluminum top cap
installed in a later step (Figure 40
& Detail AAA).
Note: Each powered Spine Screen
has two 10-wire rigid wireways that
are pre-mounted in the base raceway
at the factory.
Note: Spine Screen electrical is
“in-line” only and does not turn
corners. Spine Screens cannot pass
power to Flex Screens.
Spine
Screen
(#2)
Spine
Screen
(#1)
Flex
Screen
spacer
top cap
(in-line)
spacer
(in-line)
#10-24 x / ”
Phillips flat
head screw
1
2
Figure 40
Spine
Screen
(#2)
Spine
Screen
(#1)
#10-24 x / ”
Phillips flat
head screw
1
2
spacer
(in-line)
spacer
top cap
(in-line)
Detail AAA
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
7. At the location specified for a
screen-to-screen jumper between
the spacer, route the jumper
through the pass-through ankles
at each end of the Spine Screen,
then plug the ends into each rigid
wireway of the powered Spine
Screens (Figure 41).
8. Route the 10-wire base power
infeed plug end of the infeed
through the pass-through ankle and
plug it into an open end of a
10-wire rigid wireway (Figure 41).
9. On the rib side of the spacer cover,
space molding clips evenly apart
and press them onto the ribs of the
cover (Figure 41 & Detail BBB).
10. Position the spacer cover with
molding clips up against the spacer
cover channel with the 10-wire base
infeed routed through the opening
at the bottom of the spacer cover.
Using a firm hand, press on the
spacer cover at the molding clip
locations to snap molding clips into
the spacer cover channel (Figure 42
& Detail BBB).
11. Reference “Leveling and
Connecting Spine Screens”
instructions on page 6 to connect
remaining screens.
Spine
Screen
(#1)
Spine
Screen
(#2)
spacer
(in-line)
10-wire
rigid wireway
screen-to-screen
10-wire jumper (21 / ”)
1
4
10-wire
rigid wireway
Flex
Screen
Figure 41
Spine
Screen
Spine
Screen
spacer
(in-line)
spacer
cover
spacer
cover
channel
molding
clip
10-wire base
power infeed
Flex
Screen
Figure 42
Detail BBB
spacer
cover
molding
clip
spacer cover
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
10-Wire Base Raceway Trim
Installation
Note: The power infeeds are to be
connected to the power source by
a qualified electrician who must
follow all state and local codes at the
building site and check the electrical
integrity of the finished system.
Note: All screens must be
mechanically connected together,
with all 10-wire rigid wireways and
screen-to-screen power connections
appropriately installed before adding
power infeed, or connecting infeed to
power source.
1. Install the base raceway trim by
aligning the trim openings with the
installed receptacle and engaging the
base trim lip with the bottom wireway
channel (Figure 43 & Detail CCC).
Spine
Screen
base
raceway
trim
Figure 43
base
trim lip
Detail CCC
base
raceway
trim
bottom
wireway
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
End-of-Run Vertical Trim
Installation
1. Per the space-planning layout, locate
the end-of-run screen. Make sure
that screen is plumb and level.
2. Determine the length of the
end-of-run vertical trim by
measuring the distance from the top
of the Spine Screen vertical frame,
down to the floor at the end-of-run
trim location. Cut the trim to the
marked length.
3. On the rib side of the end-of-run
vertical trim, space molding clips
evenly apart and press them onto
the ribs of the end-of-run trim as
illustrated (Figure 44).
4. Position the end-of-run vertical trim
with molding clips up against the
vertical frame channel. Using a firm
hand, press on the vertical trim at
the molding clip locations to snap
molding clips into the vertical frame
channel (Figure 44).
5. Place the end-of-run corner cap into
the notch formed on the top corner
of the horizontal frame. Align the
mounting holes on the horizontal
frame with the mounting holes on
the corner cap and secure with two
#10-24 x 3/8” Torx screws
(Figure 44).
Note: If Spine Screen is specified
with a topper kit and no Flex
Screen configurations are required,
proceed to page 47 for “Topper
Kit Installation” instructions. If
Flex Screen configurations will
be configured with Spine Screen
configurations and topper kits
are specified, proceed to page 42
for “Flex Screen Configurations”
instructions. If Spine Screen are not
specified with topper kits proceed to
“Flat Aluminum Top Cap Installation”
instructions on page 41.
Figure 44
Spine
Screen
end-of-run
vertical
trim
molding
clip
end-of-run
corner
cap
#10-24 x / ”
Torx screws
3
8
vertical
frame
channel
vertical
frame
horizontal
frame
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
Change-of-Height Trim
Installation
1. Per the space-planning layout, locate
the change-of-height screens. Make
sure that screens are plumb and
level.
2. Determine the length of the vertical
trim for the change-of-height screens
by measuring the distance from the
bottom of the vertical frame of the
taller Spine Screen, down to the top
of the lower Spine Screen frame at
the vertical trim location. Cut the
vertical trim to the marked length.
3. On the rib side of the vertical trim,
space molding clip(s) evenly apart
and press them onto the rib of the
vertical trim as illustrated
(Figure 45).
4. Position the vertical trim with
molding clip(s) up against the
vertical frame channel. Using a
firm hand, press on the trim at the
molding clips to snap molding
clips into the vertical frame channel
(Figure 45).
5. Place the end-of-run corner cap into
the notch formed on the top corner
of the horizontal frame. Align the
mounting holes on the horizontal
frame with the mounting holes on
the corner cap and secure with two
#10-24 x 3/8” Torx screws
(Figure 45).
Note: If Spine Screen is specified
with a topper kit and no Flex
Screen configurations are required,
proceed to page 47 for “Topper
Kit Installation” instructions. If
Flex Screen configurations will
be configured with Spine Screen
configurations and topper kits
are specified, proceed to page 42
for “Flex Screen Configurations”
instructions. If Spine Screen are not
specified with topper kits proceed to
“Flat Aluminum Top Cap Installation”
instructions on page 41.
Spine Screen
Spine Screen
Figure 45
vertical
trim
molding
clip
end-of-run
corner
cap
#10-24 x / ”
Torx screws
3
8
vertical
frame
channel
vertical
frame
horizontal
frame
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Spine Screen Trim
Assembly Instructions
Flat Aluminum Top Cap
Installation
1. On the rib side of the flat aluminum
top cap, space molding clips evenly
apart and press them onto the ribs of
the top cap as illustrated (Figure 46).
2. Position the flat aluminum top cap
with molding clips down against the
horizontal frame channel. Using a
firm hand, press on the top cap at
the molding clip location to snap
molding clips into the horizontal
frame channel (Figure 46).
Figure 46
Spine
Screen
molding
clip
flat aluminum
top cap
horizontal
frame
horizontal
frame
channel
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Flex Screen
Assembly Instructions
Flex Screen Configurations
Note: Flex Screens are free
standing, non-powered screens
designed to allow various screen
intersection options. Each Flex
Screen is either equipped with two
adjustable glide feet or one bridge
foot and one flat foot, to be used
in 90 degree configurations. See
instructions on pages 42-46 to
properly arrange the various Flex
Screen intersection configurations.
In-Line Flex Screens
Note: Reference Details A, B, C & D
for in-line Flex Screen configuration
options.
1. Carefully lift and arrange Flex
Screens in-line to each other per the
space-planning layout (Figure 1).
If screens are to install in-line in
preparation for a 3-way intersection
as illustrated on page 45 (Figure 4),
move screens in-line to one another
so that the flat foot of one screen
is adjacent to the flat foot of the
adjacent screen (Detail B).
Figure 1 - In-Line Flex Screens
Flex Screen
Flex Screen
bridge
foot
flat
foot
Detail A - In-Line Flex Screens
(bridge foot-to-at foot)
bridge
foot
flat
foot
Flex
Screen
Detail B - In-Line Flex Screens
(at foot-to-at foot)
flat
foot
flat
foot
Flex
Screen
Detail D - In-Line Flex Screens
(adjustable glide foot-to-
adjustable glide foot)
adjustable
glide foot
adjustable
glide foot
Flex
Screen
Detail C - In-Line Flex Screens
(bridge foot-to-bridge foot)
bridge
foot
bridge
foot
Flex
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Flex Screen
Assembly Instructions
Flex Screen Corner Intersections
Note: Flex Screens in the corner
intersection configuration must be
placed perpendicular to each other.
One screen must have the bridge
or adjustable glide foot rest on top
of the perpendicular screen's flat
foot. Reference Details E & F for
Flex Screen corner intersection
configuration options.
1. Carefully lift and arrange the Flex
Screens to be perpendicular to
each other per the space-planning
layout. Place the screen with the
bridge or adjustable glide foot over
the perpendicular screens flat foot
or slide the screen with the flat foot
under the bridge or adjustable glide
foot of the perpendicular screen
(Figure 2).
Flex Screen
bridge
foot
flat
foot
Flex Screen
Figure 2 - Flex Screen Corner Intersection
Detail E - Flex Screen Corner
Intersection (bridge foot
over at foot)
bridge
foot
flat
foot
Flex
Screen
Flex
Screen
Detail F - Flex Screen Corner
Intersection (adjustable glide
foot over at foot)
adjustable
glide foot
flat
foot
Flex
Screen
Flex
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Flex Screen
Assembly Instructions
Flex Screen Mid-Panel
Intersections
Note: Flex Screens in the mid-panel
intersection configuration must be
placed perpendicular to each other.
One screen will be placed up against
the middle of the perpendicular
screen. Feet do not intersect in
mid-panel intersection configurations.
Reference Details G & H for Flex
Screen mid-panel intersection
configuration options.
1. Carefully lift and arrange the Flex
Screens to be perpendicular to each
other, with one screen up against the
middle of the perpendicular screen
per the space-planning layout
(Figure 3).
bridge
foot
Flex Screen
Figure 3 - Flex Screen Mid-Panel Intersection
Flex Screen
Detail G - Flex Screen
Mid-Panel Intersection
bridge
foot
Flex
Screen
Flex
Screen
Detail H - Flex Screen
Mid-Panel Intersection
flat
foot
Flex
Screen
Flex
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Flex Screen
Assembly Instructions
Flex Screen 3-Way Intersections
Note: If the Flex Screen 3-way
intersection will be configured, the
in-line Flex Screen configuration
must be assembled first before
proceeding. Reference “In-Line Flex
Screen” instructions on page 42.
Note: The in-line Flex Screens in the
3-Way configuration must be placed
together with the flat feet adjacent to
each other. The perpendicular screen
must have the bridge or adjustable
glide foot bridge over the in-line
screen’s flat feet. Reference Detail I
for Flex Screen 3-way intersection
configuration option.
1. With the in-line Flex Screen in
it’s final location, carefully lift and
arrange the perpendicular Flex
Screen to the 3-way location per the
space-planning layout (Figure 4).
2. Place the screen with the bridge
or adjustable glide foot over the
in-line screen's flat feet (Figure 4).
Flex Screen
bridge
foot
flat
feet
Flex Screen
Figure 4 - Flex Screen 3-Way Intersection
Flex Screen
Detail I - Flex Screen 3-Way
Intersection (bridge foot
over at feet)
bridge
foot
flat
feet
Flex
Screen
Flex
Screen
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Flex Screen
Assembly Instructions
Spine & Flex Screen 3-Way
Intersections
Note: If the Spine and Flex
Screen 3-way intersection will be
configured, in-line Spine Screens
must be assembled and connected
first before proceeding. Reference
“Leveling & Connecting Spine
Screens” on page 6, then reference
appropriate electrical instructions
on pages 9-41. In-line Flex Screens
will be configured in the steps below
since Spine Screens must remain
stationary.
Note: If both Spine & Flex Screens
are to be used in a 3-way intersection
configuration, the Flex Screen will
be moved and placed up against the
Spine Screen in their final location.
Spine Screens must not be moved
during the installation since screens
were adjusted for flooring conditions,
ganged and contain power (optional)
from previous steps.
Note: The in-line Flex Screens
feet in the 3-Way configuration
must be placed individually under
the perpendicular Spine Screen
adjustable glide foot. Once both
in-line Flex Screen feet are under
the perpendicular Spine Screen
foot, carefully place the two
in-line Flex Screens against each
other. Reference Details J, K and
L for Spine & Flex Screen 3-way
intersection configuration options.
1. With the Spine Screen in it’s final
location, one at a time, carefully
lift and arrange the Flex Screen
feet under the perpendicular Spine
Screen foot per the space-planning
layout (Figure 5).
2. With both in-line Flex Screen feet
under the perpendicular Spine foot,
carefully place the two in-line Flex
Screens against each other
(Figure 5).
Figure 5 - Spine & Flex Screen 3-Way Intersection
Spine Screen
adjustable
glide foot
flat
plate feet
Flex Screen
Flex Screen
Spine
Screen
Detail J - Spine & Flex Screen
3-Way Intersection (adjustable
glide foot over at and bridge
foot)
adjustable
glide foot
flat
foot
Spine
Screen
Flex
Screen
bridge
foot
Detail K - Spine & Flex Screen
3-Way Intersection (adjustable
glide foot over at feet)
adjustable
glide foot
Spine
Screen
Flex
Screen
flat feet
Detail L - Spine & Flex Screen
3-Way Intersection (adjustable
glide foot over bridge feet)
bridge feet
Flex
Screen
Spine
Screen
adjustable
glide foot
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Topper
Assembly Instructions
Topper Kit Installation
Note: Flex screens ship assembled
with flat aluminum top caps installed
except when topper kits are specified.
1. On the rib side of the topper
connector, space molding clips
evenly apart and press them onto the
ribs of the connector as illustrated
(Figure 1).
2. Position the topper connector with
molding clips up on top of the
horizontal frame channel. Using
a firm hand, press the topper
connector down at the molding clip
locations to snap molding clips into
the horizontal frame channel
(Figure 1).
Note: Cork adhesive backed gasket
is wrapped around the bottom at the
end, and middle of acrylic toppers at
the plant. Do not remove gasket as
it is required for installation of the
acrylic topper to the connector.
3. Set and center the acrylic or felt
topper into the top opening on the
topper connector and press down
securely (Figure 1).
Figure 1
Flex Screen
or Spine Screen
(non-powered)
molding
clip
acrylic/felt
topper
topper
connector
horizontal
frame
channel
horizontal
frame
cork
adhesive
backed
gasket
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Accessories
Assembly Instructions
Slide Panel Installation
1. At the underside of each horizontal
frame are two horizontal frame
channels separated by the screen
core. Determine the location the slide
panel will mount to the frame, per the
space-planning layout (Figure 1).
2. Locate the horizontal frame access
holes at each end of the horizontal
frame channel. Insert the nylon glide
through one of the access holes and
slide panel towards the center of the
screen until the second glide can be
inserted through the same access
hole (Figures 1 & 2, Details A, B, C
& D).
Note: The slide panel has a writable
magnetic surface on one side and
a tack board on the other side.
Depending on which nylon glide you
insert first will determine which slide
panel face is facing out.
3. Two slide panel stoppers are
included with each slide panel kit.
The stoppers can be used to prevent
the slide panel from accidentally
falling out of the access holes. To
install the stoppers insert them
into the access hole and slide them
toward the center of the panel slightly
and tighten the screw to hold in place
(Detail D).
Flex Screen
or Spine
Screen
slide
panel
nylon
glide
horizontal
frame
Figure 1
screen
core
Detail A
slide
panel
horizontal
frame
access hole
horizontal
frame
channel
horizontal
frame
nylon
glide
slide
panel
horizontal
frame
channel
horizontal
frame
Detail B
Flex Screen
or Spine
Screen
slide
panel
nylon
glide
horizontal
frame
Figure 2
Detail C
slide
panel
horizontal
frame
access hole
horizontal
frame
nylon
glide
Detail D
slide
panel
horizontal
frame
channel
horizontal
frame
stopper
Assemble units as described herein only. To do otherwise
may result in instability. All screws, nuts and bolts must be
tightened securely and must be checked periodically after
assembly. Failure to assemble properly, or to secure parts
may result in assembly failure and personal injury.
Tattoo™ Screens - Accessories
Assembly Instructions
Coat Hook Installation
1. At the underside of each horizontal
frame are two horizontal frame
channels separated by the screen
core. Determine the location the coat
hook will mount to the frame, per the
space-planning layout (Figure 3).
2. Locate the horizontal frame access
holes at each end of the horizontal
frame channel. Insert the nylon glide
through one of the access holes
and slide the coat hook towards the
center of the screen. Tighten the
screw on the underside of the nylon
glide to hold the coat hook in place
(Figures 3 & 4, Details E, F & G).
3. Two coat hook stoppers are included
with each coat hook kit. The stoppers
can be used to prevent the coat hook
from accidentally falling out of the
access holes. To install the stopper
insert it into the access hole and
slide it just past the access hole
and tighten the screw to hold it in
place. If it is desired that the coat
hook be constrained to one location,
a stopper may be installed at each
side of the coat hook, at the hook's
desired location (Detail H).
Flex Screen
or Spine
Screen
nylon
glide
horizontal
frame
Figure 3
screen
core
coat
hook
Detail E
horizontal
frame
access hole
horizontal
frame
channel
horizontal
frame
coat
hook
nylon
glide
Detail F
coat
hook
horizontal
frame
channel
horizontal
frame
Detail G
horizontal
frame
channel
horizontal
frame
coat
hook
Flex Screen
or Spine
Screen
horizontal
frame
Figure 4
screen
core
coat
hook
Detail H
horizontal
frame
channel
horizontal
frame
coat
hook
stopper
1330 Bellevue Street
P.O. Box 8100
Green Bay, Wisconsin 54308-8100
1-800-424-2432
www.ki.com
KI is a registered trademark
of Krueger International, Inc.
© 2019 Krueger International, Inc.
All Rights Reserved
Code KI-AI-000036R1/KI/PDF/0719