Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway

http://www.hls-nordic.com Installation: Wall or ceiling mounting 1 3 4 2 L C1 L1 C3 N C2 For elBus,Dali or potential free contact use C1 and C2 terminals For open cabling Open the battery cover SEALED RECHARGEABLE HIGH TEMPERATURE Ni-MH BATTERY Commis. Date:___________/____________ MUST BE RECYCLED OR DISPOSED OF PROPERLY Ni-MH RED CABLE BLACK CABLE + Order no. 2925024 4.8V/1.2Ah Perm. Ch 60mA 4 HT AA 1200 4 KRMT 15/51 Battery connection

Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway

http://www.hls-nordic.com Close the battery cover Module placement (elBus,Dali,Wireless,Potential free) 5 7 9 10 6 Mode selection ON 1 2 3 4 Maintained operation ON 1 2 3 4 Non-maintained operation ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 1h (default position) 3h 8h The control of maintained or non maintained operation of the luminary is achieved through Switch 4 of DS1. For maintained operation, switch number 4 must be in ON position. For non- maintained operation, switch number 4 must be in OFF. Changing the operating mode Autonomy duration selection The user can select one of the 3 available minimum autonomy durations 1 hour, 3 hours and 8 hours. The selection must be done while the luminaire is disconnected from AC and battery supplies. The selection is achieved through Switches 2 & 3 of DS1. Switch 1 is not used. Technical label installation One additional labels is included in the package, for 3 hours duration (180). The installer must cover the default 1 hour (60) printing. Please take notice of the orientation of the label. For accomplishing 8h autonomous light, an extra battery and adaptor is required (Part No. 290BAT.9). Connect the two batteries to the adaptor and then the adaptor’s connector to the corresponding connector on the PCB. One additional label is included in the package, for 8 hours duration (480). The installer must cover the default 1 hour (60) printing. Please take notice of the orientation of the label. Dip Switch Positions (DS1) 8 Base the luminaire to the socket A test button for manual tests and reset is located next to the indications LEDs.

Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway

http://www.hls-nordic.com Battery replacement 2 4 1 3 SEALED RECHARGEABLE HIGH TEMPERATURE Ni-MH BATTERY Commis. Date:___________/____________ MUST BE RECYCLED OR DISPOSED OF PROPERLY Ni-MH RED CABLE BLACK CABLE + Order no. 2925024 4.8V/1.2Ah Perm. Ch 60mA 4 HT AA 1200 4 KRMT 15/51 Battery connection Close the battery cover Technical description Part no.: Battery (NiMH): Battery Protection: Overcharge protection / full discharge protection o 5 to 40 C Up to 95% 1h & 3h: 16hours 8h: 23hours Produced in accordance with: Ambient Temperature Range: Maximum Power Consumption: Relative Humidity: Charging Time: Technical lifetime (light source): > 100000 hours 1h & 3h: 4.8W / 5VA 8h: 5.25W / 5.4VA 138057 1h & 3h: 4.8V / 1.2Ah 8h: 2x4.8V / 1.2Ah EN 60598-1, EN 60598-2-22, EN 55015 EN 61547, EN 61000-3-2, EN 61000-3-3 Weight: Expected Battery Lifetime: Controlgear classification in accordance with IEC 62034: with automatic test function Replacement Lamp: 290057.STR 959 gr 4 years UniLED Combi ST LED 230V w/Pict 138h 27m IP20 375lm Normal Emergency 375/175/155lm 1h/3h/8h Duration At the end of their useful life the packaging, product & batteries should be disposed of via a suitable recycling centre. Do not dispose of with your normal household waste. Do not burn.

Honeywell Life Safety AS, Po. Box 3514, N-3007 Drammen, Norway

http://www.hls-nordic.com Note: If the supply cable of the luminaire is damaged, it shall exclusively be replaced by a competent person in To avoid that luminaires perform their battery test at the same day, connect the battery packs with more than 1,5 minutes in between. Important notice when installing luminaires within the same area!!! Note: In case of mains power disconnection for a period of more than two months, the battery must be disconnected. Note: In case of battery or light source replacement, these must be replaced with parts of the same type. The replacement must be performed by the manufacturer or a competent person. The UniLED is a self-contained luminary with selftest function. it can be configured as maintained or non- maintained. Selftest functions Note: When using DALI or Wireless communication, the frequencies and schedules for tests will instead be determined by the connected PC software. Every 15 days the luminaire will perform an emergency operation test. This will light the white LEDs for approximately 3 seconds. The red LED will flash during this test sequence. Every 6 months the luminaire will perform a battery condition test. The test will last for the stated duration. The white LEDs will be lit and the yellow LED will flash during this test sequence. Manual test functions Emergency operation test: In case that the luminaire no longer meets its rated duration of operation, the battery must be replaced. Press the TEST button more than 10 seconds to delete all indicated errors. The luminaire enters regular operation mode. Press the TEST button less than 5 seconds. The white LEDs light for about 3 seconds and the red LED flashes. Battery condition test: Press the TEST button for 5 to 10 seconds. This test will last for the stated duration and can only be performed when the battery is fully charged (steady green LED). The white LEDs light and the yellow LED flashes. Resetting errors: Indicator LEDs LED Status explanation Description GREEN RED Normal Charging (battery test not possible while charging Mains off, battery not connected or charger fault Battery fault Battery test Light source test Light source fault Battery fault and light source fault Off On Flashing YELLOW