Honeywell UCIP-GPRS Quick Start Manual

Specifications

Brand: Honeywell
Category: Control Unit
Model: UCIP-GPRS (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the Honeywell UCIP-GPRS Quick Start Manual online using the built-in PDF viewer.

Text of the manual

Honeywell Life Safety Iberia, S.L. reserves the right to do any change in this information without notice.

For accurate and updated information go to www.honeywelllifesafety.es Read carefully the product manual before to install this material. The SMB-T enclosure is designed to be installed on a Surface and inside some devices by using described holes: 1- Surface mounting: Install the enclosure in the wall close to the panel by using holes marked as (1). 2- Conventional panels NFS, VSN2 y ESS: Open the panel box enclosure and remove the left Touch Display or user label plate. Install the box under the panel mains connector. Fit the box in the panel back box by the holes marked as 2) and slightly slide it downwards. 3- Fit the UCIP Communicator in the SMB-T en closure by the 4 screw holders marked 3). Installation 1 2 4 SMB-T Enclosure installation 3 Connections Standard cable holes Settings Cut the necessary holes in the SMB-T enclosure 1- RS-232 Port or AUX Port (Panel cable link) 2- RJ45 Ethernet port (Commissioning and Network) 3- GPRS antenna (UCIP GPRS only) 4- 24Vcc External power Connect needed cables as below: STATUS LEDS Ethernet Network RJ45 RS232 / TTL* Serial port UCIP Uart1 PC Conf. DB9 DXc/ID3000 RS232 (ISO232) ID60 RS232 VSN&NFS TTL* RX 3 TX 2 2 TX 2 RX 3 3 GND 5 0V 5 4 AUX.Port.* Jp3 Jp4 RS232 Config. The UCIP/GPRS can be configured by Ethernet port with RJ45 network cable El UCIP/GPRS or by RS232 serial port (cable not provided), with it’s config tool, Hyperterminal or Telnet By default it has the following serial port and IP settings: Default Serial P. UCIP: Default IP address: 192.168.0.100 RS232: 9600 Baud Mask: 255.255.255.0 No parity Gateway:192.168.0.1 Config. Port:23 1- To configure UCIP via RS232 port, make the cable: RS232-PC Conf.DB9 2- To configure UCIP via ETHERNET, Configure your PC in the sane IP range as the UCIP: WindowsStart Control PanelNetwork center  Local area connectionchange adapter settings Properties Prot.Int(IPv4)PropertiesAlternative IP config: i.e.IP:192.168.0.50, Mask 255.255.255.0, Gateway 192.168.0.1 UCIP Console tool 3-Abra la consola de config. deUCIP o el Hyperterminal de Windows y seleccione Puerto Serie y el puerto o TCP IP con la IP del UCIP puerto 23: - Puerto Serie Com: 9600 bds,0,None,None - Puerto TCP IP Client: 192.168.0.100, Puerto 23 Consola UCIP: 4- Para acceder a Configuración , con el cursor en la ventana de conexión presione 3 veces la tecla "ESC" de su PC e inserte la clave "1234" Configuration Console / Hyperterminal ETHERNET UCIP local IP and Port ETHERNET TCPIP [local IP] [network Mask] [Gateway] [dhcp on/off] IP UCIP Config.: i.e. 192.168.0.100,Mask:255.255.255.0,Gateway:192.168.0.1;DHCP:off >TCPIP 192.168.0.100 255.255.255.0 192.168.0.1 off  >OK: Operation completed CONFIG [Port] [Parameter] : Set IP port i.e..5000 >CONFIG TCPSERVER 5000  >OK: Operation completed Note: In TG supervisor, set in panel config. Link : TCP/IP, permits multiple link 7 Config GPRS Network (i.e.FireIMT) PIN [SIM PIN] : PIN of SIM card.. -Recommended to remove SIM PIN in a celular pone to avoid lock it on error. Ej. PIN XXXX. SIM must be placed to check the PIN >PIN XXXX  >OK: Operation completed GPRS [APN mobile network][User][Password] GPRS wlapn.es honeywell honeywell  >OK: Operation completed 5 6 9 SMS Message sending to user Mobil UCIP GPRS can send SMS messages to a SMS compatible Alarm Receiver or up to 2 user mobile telephones. SMS[SMS Receiver phone][MOBILE1][MOBILE2] ej. SMS sending to user mobile phone 699887766 >SMS NONE 699887766 NONE >OK: Operation completed 2 1 1 Panel Port settings: ID3000: Level 3 :6)Config.  6) Panel Settings 17) Isolated RS232 Port setup: Integration protocol, 9600 baud, 11A. Half Duplex. Requires 24Vdc. ID60: 5)Config.1)Config. 4)Peripherals 2)RS232: Integration. Half Duplex. Requires 24Vdc. DXc: 5)Actions7)Commission1)General Options2ndSerial Port: TTP,9600. Requires 24Vdc. VSN / NFS / RP1r (TTL*): *Requires to change Jp3 and Jp4 in UCIP. Power (+) by AUX port (VSN / NFS / RP1r) 1 1 1 2 110 mm 135 mm 79m m 97m m 1 1 2 2 3 3 3 3 RS485 Port GND B - A+ RS 232: ID / DXc … TTL*: Vision/NFS RS232* Port. + % GPRS GPRS Syst RX TX F.CRA F.link Out 1 Out 2 External Power 24Vdc - + GPRS antena GND TX RX + 23 - SIM 1)Select Port type: TCP/IP Client 2)Type the UCIP IP and Port 23 3)Clic on connection >Type here your command 1234 4) TYPE CONFIG COMMANDS, as described in steeps 6 to 9, including your data (red color in the examples), separate and press ENTER to send it. 8 Central Receiver Alarm Center CRA IP UCIP GPRS permits up to 2 IP address to send system states to an IP compatible Receiver CRA1 and CRA2 CRA1 [CLIENT#][IP CRA][IP PORT][Alive T] [Password][Channel: ETH+GPRS;ETH;GPRS] i.e. Client # AAAAAA, Receiver IP 192.168.1.100 and port 10001, Alive test time 60seg, encrypted password 111111 and send only by GPRS channel: >CRA1 AAAAAA 192.168.1.100 10001 60 111111 GPRS >OK: Operation completed CRA2 [CLIENT#][IP CRA][IP PORT][Alive T][Password] [Channel_Send:GPRS+ETH;GPRS;ETH;_FAIL;_EVER] i.e. Client # AAAAAA, Receiver IP 192.168.1.102 and port 10002, Alive test time 60seg, encrypted password 111111, send only by GPRS channel and send on CRA1 fail : >CRA1 AAAAAA 192.168.1.102 10002 60 111111 GPRS_FAIL >OK: Operation completed Panel connection Install de communicator as indicated above closet o panel linking the panel communication port to the corresponding on the UCIP as described in the table on step 3). Connection examples: 1234 RS232 RS 232 (Panel) to 1+2 UCIP JP3 y JP4 UCIP TTL mode Panel VSN/RP1r/Supra ISO232 ID3000/DXc ISO232 (Panel) to 1 UCIP JP3 y JP4 UCIP RS232 mode 24V external required 0V TX CTS RX RTS DB9 (ID60) 3 4 2 1 UCIP GPRS Honeywell Stick the provided label in the enclosure cover gap oriented with the LEDs window upwards as in the figure.

Honeywell Life Safety Iberia, S.L. reserves the right to do any change in this information without notice.

For accurate and updated information go to www.honeywelllifesafety.es Read carefully the product manual before to install this material. Technical features UCIP / UCIP GPRS Default Settings Status LEDs: ALRM1 DL1-RED - EXISTING DATA WITH CRA ALRM2 DL2 RED - EXIXTING DATA WITH PANEL ALRM3 DL3-RED -GPRS BIDIRECTIONALITY ACTIVE ALRM4 DL4-RED -TCP/IP BIDIRECTIONALITY ACTIVE BLINK DL5-GREEN SOFTWARE WORKING ON: Powered inactive process Slow blinking : Process running OK Off: Inoperative Process COBER DL6- BICOLOR GSM Coverture - GREEN MAXIMUM COVERTURE - ORANGE MEDIUM COVERTURE - RED LOW COVERTURE - BLINK GPRS SERVER CONNECTED TX MOD DL7-GREEN GSM MODEM CONNECTED GPRS / GSM activity ON: Modem Active(Calling) IND01 DL9 – GREEN OUTPUT 1 STATE ( Off means CRA link failure , after 5 retries) IND02 DL8 - GREEN OUTPUT 2 STATE (Off means Panel link fault) TECHNICAL FEATURES: Power 12 a 30 Vdc (not polarized) external or via Aux port Current 45mA min / 150mA max. Communication Ports 1 x RS232 (Rx,Tx GND from 1200 to 115200 Bds) 1 x Ethernet (ADSL, LAN, etceteras...) 1 x Modem GSM (GSM, SMS, GPRS) 1 x I2C double connector and power 1 x RS485 Configuration Terminal console commands / Telnet over Ethernet and GPRS. Permits SMS message commands. Serial port 232 Rx,Tx y GND. Configurable speed and parity (1200 to 115200 Bds) Compatible Panels with SMS or Contact ID NFS Supra, Vision Plus, Vision 2Plus, ID50, ID3000 and DXC CONNEXION CRA Protocol and security Double channel de transmission over Ethernet and GPRS Connectivity checking (stay alive) and bidirectionality. Ademco Contact ID protocol IP/GPRS to CRA over ALWON 128 encrypted AES128 compatible protocol. Communicator switch security and config password key. IP Connectivity DNS compatible, DHCP and dynamic IP (IP update by alive string) Firmware update Via RS232 or GPRS by UCIP Consola Tool Dimensions (w.o. box) 86mm height x102mm width x25mm depth Enclosure Dimensions 102mm height x143mm width x39mm depth Approvals EN50136 SPT 1-6, Type X/Y REQUIRED DATA TO CONNECT THE DEVICE: For Ethernet: UCIP IP in local network Local Mask + Gateway For GPRS: APN GPRS net name User Password SIM card PIN (or remove) To a CRA: Client Number/code CRA IP IP port ALIVE time Encryptation password Information for the CRA UCIP Production Serial # S/N: Protocol UCIP Honeywell R TCPv9.0.2;R20;Lopez Bellov9.0.2 Receiver - Protocol Alwon 128 (Contact ID) INFORMACIÓN DE PRODUCTO: The UCIP and UCIP-GPRS Communicator permits to connect panels via IP by Ethernet or/and GPRS. UCIP/UCIP GPRS is compatible to connect to an IP Central Receiver Alarm center the Honeywell Fire Alarm Panels: Notifier:ID3000, ID50, NFS Supra; Morley-IAS: CONNEXION, VSN-2Plus and ESSER: ESS-2PLUS. UCIP-GPRS is shipped to be connected to the Honeywell GPRS APN to be linked to the FireIMT online server and associated services. When UCIP is connected to he compatible panels it recognizes the panel protocol and its serial port is automatically set to communicate with it. SIM card is detected at the device start up to start the GPRS modem. In some panels it is necessary to configure the Integration protocol. The UCIP SERIAL NUMBER is different on each device and must be indicated to the Central Alarm Receiver center to configure client. DEFAULT SETTINGS: Default settings includes: -Serial Port to Fire panel link : 9600 Baud, no parity, to panel port RS232 or TTL (depending on port Jumpers). -GPRS Network: SIM is required, configured to connect to Fire IMT server (port 5000) Requires SIM card provibed by Honeywell and client settings) -ETHERNET to remote link by port 5000 (TG): IP UCIP: 192.168.0.100, Mask 255.255.255.0, Gateway 192.168.0.1, Ethernet port: 5000 -CRA: Requires CRA IP address configuration, by default sends System Alarm and Fault by zones state. -SMS: SIM is required. No phone is configured: Sends complete information and device labels configured in the ID and DXc panels. . Configuration checking: The device configuration can be checked by using the CONFIG command connected to device in the configuration mode. >config SERIAL NUMBER- xxxxxxx CRA1- Suscriber:, IP:0.0.0.0, Puerto:0, Alive:0, Key:, Channel:GPRS+ETH CRA2- Suscriber:, IP:0.0.0.0, Puerto:0, Alive:0, Key:, Transmission: On fail of CRA 1; Channel:GPRS+ETH SMS/DAY- Without limit ,Send: 0 TCP/IP- MAC:00-04-A4-01-00-05, IP:192.168.0.100, Mask:255.255.255.0, Gateway:192.168.0.1, DHCP:ON, Host:E20_5 TELNET- Port:23 UART1- Speed:9600, Parity:NONE I2C- Local Address:40, Remote Address:0 RS485-Local Address:3, Remote Address:0 UDP-Address:0.0.0.0, Port:1 TCP SERVER-Port:5000 TCP CLIENT-Address:0.0.0.0, Port:1 GPRS- wlapn.com, User: honeywell, Password: honeywell GPRS SOCKET-NONE GPRS SERVER- Local Address:0.0.0.0, Local Port:5000 SMS ALARM- CRA:, User1:, User2: Configuration commands: CRA1 ACCOUNT IPADDRESS PORT ALIVE KEY: Configure the CRA account number, central IP,key and Alive period CRA2 ACCOUNT IPADDRESS PORT ALIVE KEY TRANSMISSION: Configure the CRA2 account number, central IP,key and Alive period CONFIG PORT PARAM1 PARAM2:Config Port or display configuration EVENT EVENT CODE: Config ContactID event codes EVENTNAME EVENT NAME: Config event name EXIT :Exit program console FAULT FAULT CODE: Config fault codes GSM Modem GSM Communication console GPRS APN USER PASSWORD:Config GPRS network INI :Reset configuration (no borra IP ETH) OUT OUTPUT STATUS TIMER: Enable or disable digital output PIN PIN: SIM PIN settings RESET System Reset, Cold start SMS CENTRAL_PHONE USER_PHONE1 USER_PHONE2 MAXSMS: SMS parameters configuration TCPIP ADDRESS MASK GATEWAY DHCP:Config TCP/IP ZONE ZONE SENSOR MODULE FAULT DISABLE:Config zone event codes ZONENAME ZONE NAME: Config zone name TCPIP INI : Set default IP. The INI command does not change device IP. CRAX OFF: Erase CRA X(1 o 2) settings Note: Before to install the system, check and read carefully device and connected panel manuals and don’t make any action before to understand them. Product Manuals download:

Other Control Unit Manuals