Hoffmann&Hoffmann Dripmaster EDD-4SH Operation & User’s Manual
Text of the manual
Copyright © 2015 Hoffmann & Hoffmann Ltd.
Rev. 08, December 2015
1
Dripmaster EDD-4SH
U.S. Patent No. 5,996,739 & other countries
User Guide
Document filename: Dripmaster_EDD-4SH_User Guide_22Dec15.doc
Important notice: Hoffmann & Hoffmann reserves the right to change this document without further notice due
to design improvements, functional modifications or quality/reliability amendments.
ENSURE THE FREE FLOW OF OIL
From oil tank
To drain
Entire drain tube must face downward to prevent oil backup.
Section 1: Introduction ............................................................................................................................... 5
Overview .......................................................................................................................................... 5
Section 2: Installation................................................................................................................................. 6
General............................................................................................................................................. 6
Well Site Requirements.................................................................................................................... 6
Installation Kit................................................................................................................................... 8
Mounting the Dripmaster.................................................................................................................. 8
Wiring the Power and Control Cables.............................................................................................. 9
Setting the Drip Rate...................................................................................................................... 12
Section 3: Operation ................................................................................................................................ 13
Controls and Indicators .................................................................................................................. 13
Resetting the Dripmaster ............................................................................................................... 16
Automatic Control........................................................................................................................... 16
Setting Normal (pump on) Mode Drip Rates ....................................................................... 16
Pre-lube (pump off) Mode.................................................................................................... 19
Manual Control............................................................................................................................... 19
Section 4: Theory of Operation ................................................................................................................ 20
General........................................................................................................................................... 20
Search Feature .............................................................................................................................. 22
Push-Down and Push-up Features................................................................................................ 23
Section 5: Maintenance and Troubleshooting.......................................................................................... 24
Section 6: Specifications.......................................................................................................................... 26
Overall Dimensions........................................................................................................................ 27
Section 7: Dripmaster Service Policy....................................................................................................... 28
Installation ...................................................................................................................................... 28
Repair procedure ........................................................................................................................... 28
PC Board Replacement in the Field............................................................................................... 29
Product within the Warranty Period ............................................................................................... 30
Product Out-of-Warranty Period .................................................................................................... 30
Return Instructions......................................................................................................................... 30
Terms & Conditions on reverse ..................................................................................................... 31
List of Figures
Figure 1: Dripmaster EDD-4SH ............................................................................................................ 5
Figure 2: Installation requirements ....................................................................................................... 7
Figure 3: Dripmaster—rear view showing mounting centers................................................................ 8
Figure 4: Connection box – cable routing............................................................................................. 9
Figure 5: Connection box – electrical terminals: 115 VAC unit shown................................................. 9
Figure 6: Connection box PCB – wiring diagram................................................................................ 10
Figure 7: Dripmaster control panel ..................................................................................................... 13
Figure 8: Dripmaster EDD-4SH Needle Valve Assembly................................................................... 19
Figure 9: Common Needle Valve compared to Dripmaster................................................................ 20
Figure 10: Dripmaster functional diagram .......................................................................................... 21
Figure 11: Dripmaster EDD-4SH Needle Valve Assembly................................................................. 22
Figure 12: Dripmaster dimensions...................................................................................................... 27
Figure 13: Dripmaster PC board replacement.................................................................................... 29
List of Tables
Table 1: Connection box—power and control lines............................................................................ 11
Table 2: Pump On/Off conditions ....................................................................................................... 12
Table 3: Control panel—controls and indicators.................................................................................13
Table 4: Routine Maintenance............................................................................................................ 24
Table 5: Troubleshooting.................................................................................................................... 24
Table 6: Dripmaster EDD-4SH specifications.....................................................................................26
Table 7: Oil volume fed to line shaft ................................................................................................... 26
Section 1: Introduction
Overview
The Dripmaster is an active vertical line-shaft lubrication control and monitoring device. It
automatically stabilizes the oil drip rate so as to comply with pump manufacturer's requirements.
Figure 1: Dripmaster EDD-4SH
Constant drip rate is maintained regardless of ambient temperature or hydrostatic pressure in the
feeding oil tank. This is achieved by monitoring and controlling the drip rate 55 times per hour.
There are two modes of operation:
•
Normal (pump on) mode—when the well pump is operational
•
Pre-lube (pump off) mode—ensures that the line-shaft is lubricated prior to turning on the well
pump.
Automatic switching between the Normal (pump on) and Pre-lube (pump off) modes is achieved by
remotely sending a control signal to the Dripmaster.
The SCADA interface provides:
•
Accurate oil consumption data (drip rate count)
•
Total lack of oil warning
•
Automatic pump shutdown
A built-in manual mechanism ensures oil flow even in the remote possibility of unit malfunction.
Section 2: Installation
General
The Dripmaster installation procedure is simple and does not require any special tools, but requires
site preparation.
Well Site Requirements
•
Line power (115 VAC or 220 VAC), or 24 V DC/AC must be available at the well pump.
•
An eight-wire control cable (containing wires not smaller than 22 AWG) needs to be laid
between the well pump and the local PLC enclosure.
•
A sturdy, vertical pole with a welded metal plate should be in close proximity to the well pump.
Note: For large oil tanks (35 to 50 gallons), mount the Dripmaster to the oil tank stand.
Important: The relative spacing between the oil tank, the Dripmaster, and the line-shaft inlet should be
according to Figure 2. In order to maintain minimal oil pressure on the needle valve (especially
when the oil tank is almost empty), the oil inlet should be in the range of 10 to 14 inches below
the oil tank.
10 to 14 inches
(25.4 to 35.6 cm)
1/4-inch
(0.635 cm)
copper pipe
Oil filter
Oil tank
1/4-inch flexible
copper tubing
Lineshaft
ENTIRE TUBE
MUST FACE
DOWNWARD
Figure 2: Installation requirements
The Dripmaster is supplied with the following parts:
1 – oil filter (fuel filter for ¼-inch hose)
4 – mounting bolts
8 – nuts
8 – lock washers
2 – cable bushings (glands)
Make sure that all of the kit items are present. You need to obtain ¼-inch fuel hose to complete the
installation.
Mounting the Dripmaster
1. In order to mount the Dripmaster, drill four 1/4-inch holes in the metal plate that mounts the
Dripmaster according to the drilling template shown in Figure 3.
Note: The mounting centers for the Dripmaster are shown on the back of the unit for convenience.
Mounting the unit does not require more than four bolts.
2. Remove the Dripmaster front covers.
3. Place a bolt into a mounting hole, and keep it in place by using a nut.
4. Repeat step 3 for the other bolts.
5. Secure the device to the metal plate using the remaining nuts and lock washers.
9.45 inches (240 mm)
4.33 inches
(110 mm)
For ¼”
mounting bolts
Figure 3: Dripmaster—rear view showing mounting centers
Wiring the Power and Control Cables
Power and control cables are routed through the bottom of the connection box through two strain
relief bushings.
Power cable entry
Control cable entry
Green ground wire
connects here
Figure 4: Connection box – cable routing
Wire the connection box according to Figure 5. Connections are described in detail in Table 1 on
page 11.
Control
cable
Power cable
115 VAC (220 VAC)
or
24 VDC
(24 VAC optional)
24VAC/DC S.B. - Pre-lube (pump off) mode
LL - Total lack of oil
PULSE - Drip indication
O.K.. - Sufficient lubrication
I
I
J
J
J
J
J
J
Voltage selector switch SW1:
115 VAC (220 VAC) /
24 VDC (24 VAC optional)
Note: You can shut down the pump
automatically using the O.K. relay
contacts.
Figure 5: Connection box – electrical terminals: 115 VAC unit shown
Figure 6: Connection box PCB – wiring diagram
Note: Line voltage is either 115 VAC, 60 Hz or 220 VAC, 50 Hz. The unit can be powered by line
voltage or optionally by 24 V (DC or AC).
Note: Each of the signals associated with the control signal terminal block are not polarity dependent
(24VAC/DC S.B., LL, PULSE, and O.K.).
Note: Avoid daisy-chain connections of the control signal returns – if the ground potentials of each
return differ.
1. Set the power switch SW1 located just below the transformer, for line power (115 VAC or
220 VAC) or 24 V DC/AC according to your requirements. See Figure 5.
2. Route the power cable through a cable strain relief on the left side of the connection box
(Figure 4).
3. Connect the green ground wire to a chassis screw or bolt, preferably using a ring terminal. See
Figure 4.
4. Route the control cable through the right cable strain relief (Figure 4).
5. Connect control cable according to Table 1.
The connection box power and control line descriptions are shown below.
Table 1: Connection box—power and control lines
Cable or Terminal (Figure 5)
LED
indicator
(Figure 7)
Function
Power Cable (contains 3, 18 AWG
wires)
This cable provides power to the Dripmaster. Using the
selector switch and appropriate terminal block, for line power
(115 VAC or 220 VAC) or 24 V DC/AC can be supplied.
Control Cable (contains 8, 22 AWG
wires):
Input and output control or status signals are routed through
this cable.
24VAC/DC S.B. – Pre-lube
mode
SB
When applying 24 V DC/AC to these terminals, the
Dripmaster switches to the Pre-lube (pump off) mode. The
Dripmaster rate is 2 dpm in this mode. The SB LED (item 3
in Figure 7 also lights. See page 13).
LL – Total lack of oil
OIL
A dry contact that closes when a total lack of oil condition
occurs. The OIL LED (item 1 in Figure 7) also lights. See
page 13.
PULSE – Drip indication
DRIP
A dry contact that transmits the drip rate. The contact closes
for every drop fed to the line-shaft. The DRIP LED lights
momentarily whenever an oil drop passes through the
Dripmaster.
O.K. – Sufficient lubrication
1
OK
A dry contact that closes when at least 8 dpm of oil is
present. This contact closes and the OK LED (item 2) in
Figure 7 lights. See page 13.
1 In the Pre-lube (pump off) mode, the OK contacts are always closed.
When the pump is on and the Dripmaster is in Normal mode, the OK signal indicates that oil is provided to the well
pump in excess of 8 dpm (which is the factory preset threshold). Also, when the pump is on and the drip rate falls
below 8 dpm, the OK relay contacts open and signal to the pump drive circuit to shut down the pump.
There are two possible scenarios when the Dripmaster is switched to the Normal mode:
1.
The Dripmaster was in the Pre-lube (pump off) mode and dripping 2 dpm. When the pump is turned on, the
Dripmaster is no longer in the Pre-lube mode but switches to the Normal mode (the 24 V applied to the SB
terminals shown in Figure 6 have been removed).
2.
The Dripmaster was de-powered when the pump was turned off, thus dripping 0 dpm (solenoid de-energized).
For the scenario in step 1, the Dripmaster initially drips 2dpm and gradually opens the needle valve in order to deliver
the preset drip rate (10 to 28 dpm). This process takes approximately four minutes. Initially, the OK relay contacts are
open and the OK LED is off, since the 8 dpm threshold has not yet been reached. This OK state is actually the pump
shut down signal.
Note: In order to avoid this transition period OK signal, we recommend switching the Dripmaster to Normal mode (removing the
24V from the S.B. terminals) four to five minutes prior to starting up the pump driver.
For the scenario in step 2, after the Dripmaster has been powered up, it will immediately drip oil at the rate which is
close to the preset drip rate (10 to 28 dpm), the OK contacts close and the OK LED is on.
Table 2: Pump On/Off conditions
Status
OK LED on
OK LED off
Pump on
• Drip rate greater than 8 dpm
• O.K. relay contacts are closed
• Drip rate less than 8 dpm
• Total lack of oil (OIL LED on)
• O.K. relay contacts are open
Pump off
• Drip rate is equal to or greater than 2 dpm
• O.K. relay contacts are closed
• Total lack of oil (OIL LED on)
• O.K. relay contacts are open
6. Connect the oil filter (supplied) to the oil tank (Figure 2).
Important: The oil filter is essential as it prevents blockage in the needle valve.
7. Connect the Dripmaster oil outlet (Figure 8 on page 19, and Figure 2) to the well shaft inlet by
means of flexible ¼-inch copper tubing.
Setting the Drip Rate
1. Set the dip switch settings for the Normal (pump on) mode using the drip rate setting toggle
switches. (see Setting Normal (pump on) Mode on page 16).
Note: There are 50 drops per 1 cc, and there are 3785.4 cc per gallon.
2. Replace both covers and tighten the eight cover screws so that the unit is watertight.
Section 3: Operation
Controls and Indicators
Button and indicator locations on the Dripmaster control panel are shown below.
Valve opening
Pre-lube (pump off) mode
Control mode
Close valve
Timing toggle switches
Presence of oil
5
5
8
8
2
2
3
3
Lack of oil 1
1
Drip rate
4
4
Open valve
Valve fully open
7
7
6
6
Manual operation
9
9
10
10
Valve closing
11
11
Tolerance toggle switch
12
12
13
13
Drip rate toggle switches 14
14
Range toggle switch 15
15
Drip rate display 16
16
12-second timer 17
17
Freeze 18
18
Display switch 19
19
Dripmaster window area
Figure 7: Dripmaster control panel
Table 3: Control panel—controls and indicators
Item
number
(Figure 7)
Name
Control or
Indicator
Function
1
Oil
Red LED
Lights if the valve is completely closed,
indicating a complete absence of oil.
A corresponding relay contact closes when
this LED is on. The terminal for this contact is
called LL (Lower Limit) and appears in Figure
5 on page 9. This LED requires the user to
reset the system after resolving the oil
shortage issue (see Resetting the
Dripmaster on page 16).
Indicates that sufficient oil is delivered
whether the well pump is on or off.
In the Normal (pump on) mode, this
corresponds to oil drip rates in excess of 8
dpm.
In the Pre-lube (pump off) mode, the LED
lights when the rate is between 1 and 8 dpm.
The LED is off when a total lack of oil
condition occurs, and the OIL LED lights.
A corresponding relay contact closes when
the OK LED is on. The terminal for this
contact is called O.K. and appears in Figure 5
on page 9. This terminal can be used to
directly turn off the well pump in the Normal
(pump on) mode, when drip rates are less
than 8 dpm.
3
SB
Yellow LED
Lights in the Pre-lube (pump off) mode when
24 V DC/AC is applied to the S.B. terminals in
the connection box. The drip rate in this mode
is always 2 dpm.
4
DRIP
Yellow LED
This LED flashes whenever a drop passes
the photoelectric sensors in the Dripmaster
needle valve assembly (see Figure 11 on
page 22). In the Pre-lube (pump off) mode,
the DRIP LED flashes approximately every 30
seconds, indicating that oil is flowing to the
line shaft at a 2 dpm rate.
5
OPEN
Green LED
Lights when the motor is opening the valve.
6
Open Valve SW13
Push button
Press to manually open the valve—for
troubleshooting, and can be used to shorten
the time to reach the preset drip rate.
7
UL
Yellow LED
Lights when the valve is completely open.
8
Control mode SW14
Toggle switch
Select between manual and automatic
operation:
• Manual (MAN): for emergency use only. In
this state, you can only open or close the
needle valve manually by pressing the
close valve or open valve push buttons.
• Automatic (AUTO): the Dripmaster should
always be in this mode for full Dripmaster
functionality.
9
MAN
Yellow LED
Lights in the manual mode—when the mode
switch (item 8) is in the up position
10
Close Valve SW15
Push button
Press to manually close the valve—for
troubleshooting, and can be used to shorten
the time to reach the preset drip rate.
Lights when the motor is closing the valve.
12
TOL
Toggle switch
Recommended tolerance is 1 (switch raised).
Setting 2 (lower position) is for factory tests.
13
Timing
Toggle switches
These switches are set according to the
section "Setting Normal (pump on) Mode Drip
Rates", starting on page 16.
14
Drip Rate
Toggle switches
Sets the drip rate for the pump-on mode.
Choose only one toggle switch, and push it
up to the desired dpm value.
15
SW 2 – Range
Toggle switch
Low Range is selected with the switch left.
Low Range allows 10,12,14,16, or 18 dpm.
High Range is selected with the switch right.
High Range allows 20, 22, 24, 26, or 28 dpm.
16
Drip rate
7-segment
Display
A two-digit display shows the drip rate count
17
12 ' '
Yellow LED
Flashes every 12 seconds for timing
purposes when in Normal mode. You can
count the number of drips seen during this
12-second interval and multiply them by five
to arrive at the dpm rate.
This LED is useful when you want to quickly
stabilize the drip rate by pressing the Open
Valve (SW13) or Close Valve (SW15) push
button.
18
FR
Green LED
Lights to indicate the six-second freeze
interval when in Normal mode. During this
interval, which occurs once per minute, the
needle valve may be opened or closed in
order to adjust the drip rate.
19
Display switch SW1
Toggle switch
Controls the two-digit numerical display:
• In the down position (recommended):
When pump is on, displays the last minute
drip count for a period of six seconds. The
display goes off until the next minute drip
count is displayed. When the pump is off
(Pre-lube mode), the display remains off.
The 2 dpm oil flow can be verified by
looking at the DRIP LED. This LED should
flash every 30 seconds.
• In the up position (used for factory tests
only).
Resetting the Dripmaster
There are two ways to reset the Dripmaster:
1. By removing the Dripmaster cover, and raising the Control Mode toggle switch to the MAN
position, and then back to the AUTO position.
2. By disconnecting the power source to the Dripmaster for 10 seconds, and then reconnecting it.
In both cases, the circuit voltage is interrupted and then restored.
Note: In case (2) above, a random drip rate is displayed initially which can be ignored.
Automatic Control
Make sure the Control Mode toggle switch SW14 is in the lower AUTO position (item 8 in Figure 7),
so that the Dripmaster automatically stabilizes the preset drip rate. At the end of each 60 second
interval, a short correction command is given only if there is a deviation from the desired preset drip
rate.
The valve closes if the actual drip rate is 1 drip/minute or more than the preset value.
The valve opens if the actual drip rate is 1 drip/minute less than the preset value.
Setting Normal (pump on) Mode Drip Rates
During normal operation (when the well pump is operating), the drip rate is selectable for drip rates
of 10, 12, 14, 16, 18, 20, 22, 24, 26, or 28 drips/minute (Figure 7).
The toggle switch positions for each drip rate are shown below.
10 dpm toggle switch setting
12 dpm toggle switch setting
14 dpm toggle switch setting
16 dpm toggle switch setting
18 dpm toggle switch setting
20 dpm toggle switch setting
22 dpm toggle switch setting
24 dpm toggle switch setting
26 dpm toggle switch setting
28 dpm toggle switch setting
The OPEN and CLOSE LEDs indicate whether the needle valve is opening or closing. See items 5
and 11 in Figure 7 on page 13.
Pre-lube (pump off) Mode
To select the Pre-lube mode, 24 V DC/AC must be applied to the S.B. terminals in the connection
box (Figure 5). In this mode, the drip rate is automatically set to 2 dpm.
Manual Control
This mode permits emergency operation in the rare case when there is a suspected failure of the
main circuitry.
Select the manual mode by switching the Mode toggle switch to the upper MAN position (Figure 7).
This mode bypasses the electronic control circuitry, and allows the operator to modify the drip rate
by using the Open Valve (manual) and Close Valve (manual) push buttons.
Use the Drip verification peephole (see Figure 8 below) to check the drip rate.
In this mode, power is removed from the circuitry, except for the push buttons, motor, and Manual
mode LED.
Manual oil flow switch in automatic
position (solenoid-controlled)
Drip verification peephole
Oil inlet
Oil outlet
Internal solenoid
Note: For the switch position
shown below, the valve is
always open (independent of
the solenoid).
Figure 8: Dripmaster EDD-4SH Needle Valve Assembly
The internal solenoid is powered by the Dripmaster power source. When powered up, the solenoid
allows oil flow. When powered down, the solenoid blocks oil flow.
To allow oil flow when the Dripmaster is not powered on, turn the manual oil flow switch to the right
90 degrees.
Section 4: Theory of Operation
General
The Dripmaster is a gravity-based oil lubrication system.
The common needle valve fed from an oil tank does not provide any regulation of the drip rate—the
rate varies in response to variations in temperature (day versus night and time of year) and changes
in the tank oil level (hydrostatic pressure). Another cause of rate fluctuation is temporary valve
blockage.
The Dripmaster performs as an automatic needle valve that regulates oil flow (Figure 9).
200
180
160
140
120
100
80
60
40
20
0
200
180
160
140
120
100
80
60
40
20
0
0
2
4
6
8
10
12
0
2
4
6
8
10
12
Drops per minute
Drops per minute
Elapsed time (hours)
Elapsed time (hours)
Needle Valve Dripper
Dripmaster
Figure 9: Common Needle Valve compared to Dripmaster
The components that make this possible are described below.
The servo motor regulates the needle valve aperture according to the preset drip rate value. A
photoelectric sensor detects the drips and reports the drip count to the control circuitry. The control
circuitry sets the mode of operation and generates the alarms and drip count information to the
SCADA interface.
The Dripmaster EDD-4SH incorporates a specially-designed needle valve connected to a servo
motor which automatically compensates for rate fluctuations. The compensation magnitude is
defined by the control circuitry. For example, if the drip rate set point is 20 drips/minute, and the drip
rate drops below that level for any reason, the servo motor that attaches to the needle valve opens
it to increase the drip rate to maintain 20 drips/minute. Conversely, if the drip rate exceeds the set
point, the servo motor closes the needle valve to maintain the set point value (Figure 10).
Oil Outlet to Shaft
Oil Inlet
from Reservoir
Lack of
Oil
O.K.
state
Drop
Pulses
Normal/Pre-lube
Modes
Line voltage
(115V or 230 V)
or 24V Feed
To SCADA Interface
Control Circuitry
Power
Supply
Servo
Motor
Preset Selectors & Display
Figure 10: Dripmaster functional diagram
A two-digit display is visible in the Dripmaster display window (see Figure 7 on page 13)—this is a
drip counter that freezes for six seconds for each one minute interval and indicates the number of
drips applied during the previous minute (Freeze mode).
During the freeze period, the servo motor is actuated to compensate for drip rate deviations.
A built-in fail-safe relay (O.K. relay) is energized when the drip rate exceeds eight drips per minute
in the Normal (pump on)l mode. External dry relay contacts permit direct control, such as pump
shut-off. Other dry contacts in the Dripmaster are available to transmit the drip rate, and for warning
of a total lack of oil condition.
The Dripmaster EDD-4SH contains two drip rate settings, depending on the mode of operation:
•
Normal (pump on) mode—the following values are selectable:
•
10, 12, 14, 16, 18, 20, 22, 24, 26, or 28 drips/minute (dpm)
•
Pre-lube (pump off) mode—in this mode, the drip rate is automatically set to 2 dpm.
A built-in, SCADA-compatible report-back mechanism provides the status and alarm information.
This information is sent to the local PLC on site. The following signals are reported:
•
OK state – signals that the oil drip rate exceeds a factory-set threshold. Whenever the oil drip
rate falls below this threshold, the OK state is disabled and a relay contact can turn off the well
pump directly or signal the SCADA room, which in turn can shut down the pump.
•
Drip rate count– transmits the oil drip rate to the SCADA room, thereby providing the data to
calculate oil consumption.
•
Lack of oil alarm – the Dripmaster detects and warns of a lack of lubrication, as a result of an
empty oil tank or blockage in the oil inlet or outlet.
Manual operation is possible using the OPEN and CLOSE push buttons on the control panel. The
built-in peephole allows the operator to count the drips per minute.
Switching between the Pre-lube (pump off) mode and Normal (pump on) mode is accomplished by
applying or removing a 24 V DC/AC voltage to the S.B. terminals in the connection box. Applying a
24 V DC/AC voltage sets the Dripmaster to the Pre-lube mode of operation. Removing the
24 V DC/AC voltage causes the Dripmaster to switch to the Normal (pump on) mode.
Search Feature
In exceptional cases, where only a few drops are counted, or none at all, the drip search function is
activated. This situation occurs if there is needle valve blockage or when there is a continuous flow
of oil. In the continuous flow case, there are no individual drops and consequently no counter
readings. Continuous oil flow may occur when filling an almost empty oil tank, for example. In case
of partial blockage, the drip search function scans until drops appear (the needle valve opens
continuously until drops are detected). If no drops are detected during the drip search (if the oil
blockage or continuous oil flow persists), then the needle valve eventually reaches its upper limit,
the UL LED illuminates briefly, and the motor changes its direction of rotation and starts to close the
needle valve (Figure 11).
Internal solenoid
Manual oil flow switch
Overflow/vent hose
Photoelectric sensor
Drip verification peephole
Servo motor
Needle valve assembly
Upper Limit switch
Oil inlet
Oil outlet
Lower Limit switch
Control circuitry
interface
Figure 11: Dripmaster EDD-4SH Needle Valve Assembly
When and if oil drops are detected, the search function stops, and normal stabilization resumes. If
no drops are detected while the needle valve is closing, then the needle valve eventually reaches its
lower limit and the OIL LED lights continuously. The LL relay outlet contact closes, transmitting a
total lack of oil condition. At this stage, there is no vertical line-shaft lubrication which means that
either the oil tank is empty or there is an oil flow blockage between the oil tank outlet and the
Dripmaster inlet.
In the case of oil flow blockage in the Dripmaster outlet pipe, excess oil briefly flows from a built-in
overflow hose (see Figure 11 above). Also, the OIL LED turns on, and oil flow is cut off by the
closure of the needle valve. After taking corrective measures, you must reset the system. See
"Resetting the Dripmaster" on page 16.
The internal solenoid provides instantaneous on/off control of oil flow. Whenever the system power
(115 VAC, 220 VAC, or 24 V DC/AC) is on, the energized solenoid allows oil flow. Oil flow stops
when the system power ceases. The oil flow can be manually opened or closed via the manual oil
flow switch (Figure 11). When the solenoid switch is in the vertical position, operation is automatic
(controlled by the solenoid). Turn the solenoid switch 90 degrees clockwise to the horizontal
position for continuous oil flow that is independent of the solenoid.
Push-Down and Push-up Features
In order to enhance the response time of the system whenever the drip rate exceeds 80 dpm, an
automatic push-down mechanism is engaged. This is achieved by continuously closing the valve for
a number of seconds. Excessive drip rates may occur when filling an empty oil tank, or when the
Dripmaster has finished scanning.
Similarly, an automatic push-up mechanism accelerates the stabilization of the system whenever
the Dripmaster is transferred from the Pre-lube (pump off) mode to the Normal (pump on) mode.
This mode change occurs when the 24 V DC/AC is removed from the S.B. terminals in the
connection box.
Section 5: Maintenance and Troubleshooting
Table 4: Routine Maintenance
Task
Frequency
Check for oil leaks
Monthly
Oil filter change (the oil filter used can be an
automotive fuel filter with ¼" fittings)
Every six months
Check for normal operation
• The displayed drip rate is equal to the Normal (pump
on) mode drip rate setting, within a -1, +1 digit
tolerance
Weekly
Table 5: Troubleshooting
Problem
Possible Cause
Solution
The display and LEDs are not lit.
• The unit is not powered.
• Check power in the connection
box.
An unusual result appears on the
display
• Changing the mode toggle
switch (item 8 in Figure 7 on
page 13).
• Ignore.
You want to quickly stabilize the
Dripmaster for a new drip rate
• You just refilled the oil tank.
• You just increased the drip rate
setting in the Normal (pump on)
mode.
• With the Mode toggle switch
(item 2 in Figure 7 on page 13)
in automatic (AUTO), hold
down the Close push button
momentarily to slow down the
drip rate.
• With the Mode toggle switch in
position AUTO, hold down the
Open push button momentarily
to speed up the drip rate.
A suspected fault has occurred in
the system; the drip rate is much
higher or lower than expected.
• Circuit failure
• Set the Mode switch to MAN,
and set the drip rate manually
using the Open and Close
push buttons. See Figure 7.
The OIL LED is on.
• Oil tank is empty
• A shut-off valve at the outlet of
the oil tank might be closed
• Oil flow from the oil tank may be
obstructed; the oil filter may be
clogged
• Oil blockage between the
Dripmaster outlet pipe and the
line-shaft—excessive oil briefly
flows from a built-in overflow
hose
• Refill the oil tank
• Open the shut-off valve
• Change the oil filter, or clean out
any obstructions in the pipe
between the oil tank and the
Dripmaster inlet
• Clean out any obstructions in
the pipe between the
Dripmaster outlet and the line-
shaft.
Note: Reset the system after fixing
the problem. See Resetting
the Dripmaster on page 16.
Initially, the drip search is
engaged within 90 seconds.
The drip search causes the
motor to open the needle
valve until drops are
detected, after which normal
stabilization occurs.
Section 6: Specifications
Table 6: Dripmaster EDD-4SH specifications
Power requirements
115 VAC, 60 Hz, 10 VA, or 24 V DC/AC
220 VAC, 50 Hz, 10 VA or 24 V DC/AC
Normal mode preset drip rates (pump on)
10, 12, 14, 16, 18, 20, 22, 24, 26, 28 dpm
Pre-lube mode drip rate (pump off)
2 dpm
Drip volume
50 drops per 1 cc
PULSE relay contact
35 VDC – 0.5 A
O.K. relay contact
250 VAC – 10 A AC1
110 VAC – 10 A AC1
110 VDC – 0.3 A
30 VDC – 10 A
L.L. (low oil level) relay contact
125 VAC – 0.5 A
110 VDC – 0.2 A
24 VDC – 1 A
S.B. (Normal/Pre-lube mode control)
24 V DC/AC
Duty cycle
60 secs count
6 secs freeze
Drip stabilizing tolerance
x when SW 18 is UP
x to x+1 when SW 18 is DOWN
(where x is the pre-selected drip rate)
Oil on/off solenoid
24 VDC
24 VAC (optional)
Oil inlet/outlet
Male thread ¼" BSP
Dimensions (W x H x D)
10.24 x 11.02 x 3.54 inches (260 x 280 x 90 mm)
Weight
11 lbs (5 kg)
All specifications shown are subject to change.
Table 7: Oil volume fed to line shaft
Drip Rate (dpm)
2
10
12
14
16
18
20
22
24
26
28
Volume: ml/ hour
2.4
12
14.4
16.8
19.2
21.6
24
26.4
28.8
31.2
33.6
Volume: gal./ day
0.015
0.076
0.090
0.105
0.12
0.135
0.15
0.165
0.18
0.195
0.21
Volume figures are based on a Dripmaster drop volume of 50 drips = 1 ml.
1/8 inch BSP
Display window
Oil inlet
1/8 inch BSP
Connection
box
1/4-inch screws
(8 places)
4.80 inches
(12.2 cm)
Power cable entry
Control cable entry
Figure 12: Dripmaster dimensions
The Dripmaster enclosure is made of painted, cast aluminum.
Section 7: Dripmaster Service Policy
This policy has been established to cover the servicing of Hoffmann & Hoffmann products,
regardless if it is within or beyond the warranty period.
Installation
1. The installation services required for the Dripmaster includes the following:
a.
Infrastructure (trench digging, cable laying)
b.
Oil tank stand
c.
Dripmaster mount
d.
Cabling (4 pairs)
e.
24V (DC or AC) power source
f.
Testing
2. Hoffmann & Hoffmann's representative or its authorized subcontractors will perform the
installation work required and charge the customer directly.
3. In cases where there is a prior approval by Hoffmann & Hoffmann, the customer may do the
installation.
4. The representative will assume full responsibility for the installation work he performs.
Repair procedure
1. In case of a default, the customer can follow the Troubleshooting table (Table 5 on page 24) to
try and solve the problem.
2. If the customer does not succeed in solving the problem, he can fax or email Hoffmann &
Hoffmann's local representative, describing the problem based on the Troubleshooting table
(Table 5 on page 24), and indicating which of the procedures failed ("the notice"). This should
be directed to the local representative where he has a service agreement.
3. Hoffmann & Hoffmann's representative will respond within two working days.
4. The problem might be fixed by the representative in one or more of the following ways:
a.
Remotely: instruct the customer on how to solve the problem by phone.
b.
On Site: technician arrives at the customer’s site to perform first level support (basic
repairs and parts replacements).
c.
In Hoffmann & Hoffmann lab: ship the unit to Hoffmann & Hoffmann’s Chicago office.
5. The representative should first try to solve the problem remotely.
6. In case the problem is not solved remotely, the representative will send a technician to solve the
problem on site, within two working days.
7. If the representative concludes that the problem can only be solved in Hoffmann & Hoffmann's
lab, he should disconnect the unit and ship it to Hoffmann & Hoffmann's Chicago office.
8. The representative has the option to replace the faulty unit with one of his spare units.
9. The repaired unit should be shipped back from Hoffmann & Hoffmann to the representative.
10. The representative will send the repaired unit, with the repair invoice and shipment cost, to the
customer.
PC Board Replacement in the Field
11. Remove both covers to gain access to the PC boards, and then follow directions shown in
Figure 13 below.
2. Remove main
PCB mounting
screws
3. Remove cable
connectors and
terminal block
wires
Note: Replacement PC
board comes with
cables, connectors,
and terminal block
wires.
Figure 13: Dripmaster PC board replacement
Reverse procedure above to install the replacement PC board
Product within the Warranty Period
1. All Hoffmann & Hoffmann products have a one year limited warranty.
2. Hoffmann & Hoffmann Warranty will apply only to units installed by authorized Rep/Distributors
or by the customer (if Hoffmann & Hoffmann authorized installation by the customer).
3. Hoffmann & Hoffmann is not responsible for damages caused by extreme environmental
factors, i.e. temperature extremes.
4. If the failure occurred during the Warranty Period, Hoffmann & Hoffmann will cover the repair
cost. The customer will only pay for the shipment to the nearest Hoffmann & Hoffmann office.
Product Out-of-Warranty Period
1. If product is not under warranty, the customer will be responsible for all of the repair cost as per
his agreement with the representative including:
•
Technician labor cost
•
Spare parts cost
•
Other expenses (travel, shipment)
2. Repairs at Hoffmann & Hoffmann lab: if the product arriving to the lab is out of the Warranty
Period or if failure is deemed by the factory to have been caused by abuse or tampering, the
following procedure applies:
a.
Diagnosis will be made and repair completed, providing the repair charges are less than
$500 USD.
b.
We will diagnose (but not repair) a returned unit and notify by email or by fax the estimated
charges if any of the following apply:
i.
Repair charges exceed $500 USD.
ii.
You specifically requested an estimate of required repairs and charges.
iii. When the product is over 7 years old. Hoffmann & Hoffmann takes pride in attempting
to repair products of any age. However, due to component availability and product
improvements, some older products may no longer be repairable.
c.
When you receive an estimate and would like us to proceed, please mail or fax one signed
copy (with P.O. number if required) or phone or email your authorization.
d.
Note: Un-repaired items are discarded unless you wish them to be returned to you. There
is currently a $150 charge plus shipping per un-repaired item to cover diagnosis and
handling such returns. Items remaining more than 90 days from estimate date will be
discarded.
e.
Service warranty period is ninety days for all repaired/replaced parts.
Return Instructions
1. When sending your product for repair, please include the following information:
a.
Company name and address
b.
Contact name
c.
Phone, fax and/or email
d.
Description of the problem(s)
2. Return properly packaged item to the address of your local Rep/Distributor or to Hoffmann &
Hoffmann lab.
3. This warranty is limited to the repair or replacement of the Hoffmann & Hoffmann products only.
Hoffmann & Hoffmann assumes no other responsibility or liability.
4. Hoffmann & Hoffmann reserves the right to make changes in policy and pricing without notice.
Terms & Conditions on reverse
The purchaser agrees to the following terms and conditions:
1. Shipping:
a.
If not specified, goods will be shipped by the most economical carrier of our choice.
Domestic orders will be shipped GROUND unless specified. International orders will be
shipped AIR unless specified.
b.
To obtain warranty service, you must deliver the product in either its original packaging or
packaging affording an equal degree of protection.
2. Insurance: Insurance costs will be added to all invoices.
3. F.O.B.: Free On Board. ALL goods are shipped F.O.B. All shipping and insurance costs, local
and/or foreign taxes or exportation / importation duties are the responsibility of the customer.
4. Claims: Claims for damage sustained in transit should be made promptly to your carrier.
5. Force Majeure: Hoffmann & Hoffmann shall not be liable for any delay in or impairment of
performance resulting in whole or part from acts of nature, labor disruptions, shortages, inability
to procure product, supplies or raw materials, severe weather conditions, or any other
circumstances or cause beyond the control of Hoffmann & Hoffmann in the conduct of its
business.
Hoffmann & Hoffmann Ltd., 7 Shoham Str., P.O.Box 7544, Petach Tikva 49170, Israel