Know F4 PRO

F4 PRO is the first stand-alone remote 4-channel dosing pump of Kamoer. It is mainly used to quantitatively add aquarium additives, such as Ca, Mg and KH supplements. It easily maintains water quality and greatly reduces the user workload. F4 PRO uses plastic gear to directly drive the pump head for increasing accuracy/precision, no slip and rust. Each channel is distinguished by one color housing, corresponding to the connecting tube of 4 colors, which are easy to distinguish and very fashionable. Highly reliable threaded joints are used to ensure no leakage problem. Standard long life pump tubing. Support both iOS and Android devices control by app. 1. KFS pump head 2. Outlet 3. Inlet 4. Status indicator (red) 5. Power indicator (green) 6. Reset button (Reset) 7. CAN communication (CAN1/CAN2) 8. Power jack (DC12V)

1. Scan the QR code on packing box or below, download the app of the icon below.

iOS Android 2. Go to App Store or Google Play, search "kamoer remote" to download. Note: This app supports IOS 9.1 and above Apple devices, Android 4.4 and above Android devices. Register account You need to register an account and login by kamoer remote app before using your F4 PRO. E-mail registration or mobile registration is optional. Follow the guidelines to complete registration and login.

Click the icon in the upper left corner of the device list page to enter the "User" page, click

"Tutorial" on the page to enter the product selection page, select "F4 PRO" to view the tutorial. The tutorial includes the user manual and FAQ. Indicator Indicator Status Description Status Indicator (Red) On F4 PRO is online Off F4 PRO cannot connect to the wireless router Fast flashing F4 PRO is in the state of network configuration, the app can configure the dosing pump to connect the router Slow flashing F4 PRO is offline Power Indicator (Green) On F4 PRO is powered on Off F4 PRO is not powered on or power failure

Connect F4 PRO to the cloud

Power on F4 PRO for the first time after unpacking, the status indicator (red) flashes slowly. At this time, you need to use the App to connect the dosing pump to the cloud through the wireless router. The specific steps are as follows: 1. Ensure that the wireless router can connect to the Internet; 2. Press and hold the Reset button on the right panel, and release the button until the status indicator (red) flashes twice and the buzzer sounds twice; 3. Wait for the status indicator to change to a fast flashing state, indicating that the dosing pump is already in the state of network configuration. 4. Connect the mobile phone to the 2.4G WIFI hotspot of the wireless router (the device does not support 5G WIFI and cannot use 5G WIFI hotspot); 5. Open the Kamoer Remote app, log in with the registered account, click the "+" icon in the upper right corner, select "Add device" , select "Kamoer_F4 PRO" in the list of supported devices, and then follow the app prompt to complete the connection router operation. 6. After the connection is successful, the app will prompt the connection to be successful. At this time, the status indicator (red) is on, indicating that the dosing pump is connected to the cloud. At this time, the user has also completed the binding with the dosing pump. Bind F4 PRO There are two ways for the user to bind the dosing pump. The first way is to bind the dosing pump through the method above; the second way is that the dosing pump has been connected to the cloud through the wireless router, and the mobile phone can be connected to the wireless under the router, the app will display the locally available dosing pump. The user can directly click the corresponding "Bind" button on the right side to bind the dosing pump in the list of scanned dosing pumps.

Long press the corresponding device icon on the device list page, the "Remove" icon

will pop up at the bottom, and click the "Remove" icon to unbind. Notes  Please use the product's own power adapter and work in the specified working environment.  This product only supports 2.4G WiFi and does not support 5G WiFi.  The dosing pump should be placed in a reasonable position to ensure that the height difference between the inlet and the outlet is within 0.5 m.  The connection pipe for liquid inlet should be as short as possible, and the outlet connection pipe should be suspended above the container.  Please check carefully that the inlet and outlet connections are in the correct direction.

Dimensions(L*W*H) 250x59x49 mm

Weight 950g (without power adapter) Power adapter Input:See the power adapter label for details Output: DC12V 2A Dosing parameters Dosing channel: 4 KFS pump heads Flow rate: >45 ml/min Number of dosing: 24 times / day - 1 time / 99 days Dosing volume accuracy: <±0.5% Manual does amount: 1 ml - 9999 ml Interface WIFI and CAN communication interface Working environment Temperature 0 - 70 ° C, humidity 10% - 90% (non-condensing) Storage environment Temperature -20 ° C - 85 ° C, humidity 10% - 90% (non-condensing) Packing list No. Name Specification Unit Qty 01 Dosing pump F4 PRO set 1 02 Power adapter body DC12V 2A pcs 1 03 Power adapter plug US UK EU AU pcs 1 04 Plastic cylinder 10ml pcs 1 05 PVC connecting tube 3*5;red meter 2 06 PVC connecting tube 3*5;yellow meter 2 07 PVC connecting tube 3*5;blue meter 2 08 PVC connecting tube 3*5;green meter 2 09 connecting tube clamp Transparent pcs 2 10 tube holder pcs 1 11 Fixing screw ST2.9*13 pcs 4 12 Quick start guide English pcs 1 13 Product certification pcs 1

Warranty service is only valid for users who are correctly installed, used and

maintained according to the manual. Any malfunction or damage is not covered by the warranty. Please keep your purchase voucher properly so that you can get satisfactory after-sales service in time. The company will provide free warranty service for any damage caused by manufacturing processes or components within one year from the date of purchase. The free repair service provided during the warranty period includes free repair, free replacement and replacement of faulty spare parts, and products that cannot be repaired are replaced by the same model. The free service does not include shipping costs for the product due to repairs Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We reserve the right to improve or alter appearance and technical specifications without notice.