Johnson & Starley Q-VENT COMPACT-R Erection Installation, Commissioning & Servicing Instructions

File Specifications

Brand: Johnson & Starley
Category: Fan
Model: Q-VENT COMPACT-R (Erection Installation, Commissioning & Servicing Instructions), prN9LHP7MTpbI
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 20 pages

Download PDF

Download Johnson & Starley Q-VENT COMPACT-R Manual (20 pages)

Read Online:

Read the Johnson & Starley Q-VENT COMPACT-R Erection Installation, Commissioning & Servicing Instructions online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

In the interest of continuous development Johnson and Starley reserve the right to change specification without prior notice.

Johnson and Starley prides itself on it’s ability to supply spare parts quickly and efficiently. CONTENTS 1 Features 3 2 General Description 3 3 Carton Content 4 4 Building Standards & Regulations 5 5 Safety, Electrical & Water Information 5 6 ErP Fiche Technical Data 6 7 Preparation & Positioning 7 Ducting Information Positioning The Unit Spigots Condensate Typical Room Layout 8 Duct & Duct Connections 9 9 Installation Instructions 10 10 ...

Sales/Replacement Telephone 01604 762881

14. SERVICING & MAINTENANCE IMPORTANT: Before commencing any servicing or component replacement. Ensure the ELECTRICAL SUPPLY to the unit is ISOLATED. NOTE: This unit is suspended and care MUST be taken when removing the access panel. Take care no components fall out. 14.1 All filters must be cleaned first before commencing servicing and maintenance. See Figure 15. 14.2 Remove the magnetic strips and remove the filters. See Section 15 for cleaning. 14.3 The supply and extract fans and heat exchanger need cleaning annually. See Paragraph 14.5 & 14.7. ...

Sales/Replacement Telephone 01604 762881

1. FEATURES 2. GENERAL DESCRIPTION 2.1 The Q-Vent Compact-R System provides mechanical ventilation to the living/bedroom. The unit is designed to provide continuous low level extraction from the wet rooms via a system of fixed ductwork and grilles. Heat is recovered from the stale contaminated air drawn from the wet room and uses a high performance heat exchanger recovering the heat and transferring it to temper the incoming fresh air into the living/bedroom. The ventilation rate will increase when the wet room is being used for periods of time, in e ...

PRE COMMISSIONING CHECK

Before commencing the commissioning procedure, refer to the design drawing for correct air flows. See Figure 5. NOTE: Extract air and supply air volumes will not always be equal, therefore, when setting up, the extract system should be the datum. 13.1.1 Ensure that the exhaust and supply grilles or valves are open. 13.1.2 Check the airflow at the grilles or valves, and adjust to suit the design figures. 13.1.3 For bathroom extract this unit is factory set for 8 l/s in trickle mode and 24 l/s in boost mode, based on t ...

Sales/Replacement Telephone 01604 762881

FIGURE 10. Q-VENT COMPACT-R WIRING DIAGRAMS 12. CIRCUIT DIAGRAMS COLOUR CODE BN BROWN BU BLUE BK BLACK GNYE GREEN/YELLOW RD RED WH WHITE YE YELLOW FIGURE 11. JS9 SWITCH WIRING DIAGRAM ...

FIGURE 13. PCB BOARD (default settings)

RV2 INSTALLER MODE SWITCH DIP SWITCH RTC TEST SWITCH L RED LED FLASHING LIGHT RV1 TABLE 6 SWITCH FUNCTIONS (Information Only) SWITCH SWITCH POSITION DEFAULT SETTINGS SWITCH POSITION 1 ON Both fans externally controlled at the same time OFF Single fan externally controlled (supply fan with CTA linked to CTB) 2 ON Condensate detection mode ON OFF Condensate detection mode OFF 3 OFF Extract Boost Delayed for 2 minutes with Switch Live Present ON Extract fan boost speed not delayed with Switch Live present 4 ON Supply Fan 1 boo ...

Sales/Replacement Telephone 01604 762881

14. SERVICING & MAINTENANCE IMPORTANT: Before commencing any servicing or component replacement. Ensure the ELECTRICAL SUPPLY to the unit is ISOLATED. NOTE: This unit is suspended and care MUST be taken when removing the access panel. Take care no components fall out. 14.1 All filters must be cleaned first before commencing servicing and maintenance. See Figure 15. 14.2 Remove the magnetic strips and remove the filters. See Section 15 for cleaning. 14.3 The supply and extract fans and heat exchanger need cleaning annually. See Paragraph 14.5 & 14.7. ...

Johnson & Starley Ltd

Rhosili Road, Brackmills, Northampton NN4 7LZ [email protected] [email protected] Reception/Customer Service 01604 762881 Fax 01604 767408 In the interest of continuous development Johnson & Starley reserve the right to change specifications without prior notice. Anniversary 1922 - 2012 ...

Johnson & Starley Q-VENT COMPACT-R user guide recommended for: Dryflow A25 Series, HOVER 60, R3G500-AF32-11, Q-VENT COMPACT-L, 5D51-35.

⚠️ Download Safety

The Fan Erection installation, commissioning & servicing instructions (20 pages) is completely safe to download (last scan date: 14/02/2026).

Related PDF Instructions for Johnson & Starley Q-VENT COMPACT-R:

Fan Equipment: Frequently Requested

Have some Questions about Johnson & Starley Q-VENT COMPACT-R Device?

Get valuable and actionable advices from other Johnson & Starley Q-VENT COMPACT-R device users. Describe your problem or question, regarding the using of Q-VENT COMPACT-R, in as much detail as possible, and other users will be able to answer you.