Dell PowerConnect 8024 Release Notes
Text of the manual
Dell™ PowerConnect™ 8024/8024F
PowerConnect
8024/8024F
Release Notes
Date: March 2011
System Firmware Version 3.1.4.16
Information in this document is subject to change without notice.
© 2011 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo and PowerConnect are trademarks of Dell Inc; Intel and Pentium are registered trademarks
and Celeron is a trademark of Intel Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entity claiming the marks and names or their products.
Dell Inc disclaims any proprietary interest in trademarks and trade names other than its own. All rights reserved. This document may not, in
whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form without the
prior written consent of Dell. Dell reserves the right to make changes without further notices to any products or specifications referred to
herein to improve reliability, functionality or design.
Reproduction, adaptation or translation without prior written permission is prohibited, except as allowed under the copyright laws.
System Firmware Version 3.1.4.16
Table of Contents
Introduction
3
Global Support
3
Firmw are Specifications
3
Hardw are Support ed
3
Features Introduced in this Rel ease
4
Release 3.1.4.16
4
Release 3.1.4.8
4
Release 3.1.4.5
4
Changed Functionalit y in this Release
5
Release 3.1.4.16
5
Release 3.1.4.8
5
Release 3.1.4.5
5
Issues Resol ved
6
Release 3.1.4.16
6
Release 3.1.4.8
7
Release 3.1.4.5
7
Know n Restrictions and Limitations
12
Interfaces
12
Layer 2
13
Layer 3
15
Management
17
End of Release Notes
18
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 3
Introduction
This document provides specific information for the Dell PowerConnect 8024/8024F switches, firmware version 3.1.4.16.
It is recommended that this release note be thoroughly reviewed prior to installing or upgrading of this product.
Global Support
For information regarding the latest available firmware, release note revisions, or additional assistance, please visit the Support
Web Site http://support.dell.com/.
Firmware Specifications
Firmware Version Details
Boot PROM Name
Version No.
Release Date
Not Applicable
3.1.4.16
March 2011
Firmware Image Name
Version No.
Release Date
PC8024v3.1.4.16
3.1.4.16
March 2011
Version Numbering Convention
Version number
Description
PC8024/PC8024F
3
1
4
16
Four part version number
Denotes the build number.
Denotes an ad hoc release of the product software.
Denotes a scheduled maintenance release of the product software.
Denotes a major version number.
Supported Firmware Functionality
For more details regarding the functionalities listed, please refer to the Dell™ PowerConnect™ PC8024/PC8024F Switches CLI
Reference Guide and the Dell™ PowerConnect™ PC8024/PC8024F Switches Configuration Guide.
Hardware Supported
PowerConnect 8024F
PowerConnect 8024
PowerConnect 8024/8024F Release Notes
Page 4
System Firmware Version 3.1.4.16
Features Introduced in this Release
Release 3.1.4.16
No new features introduced in Release 3.1.4.16.
Release 3.1.4.8
No new features introduced in Release 3.1.4.8.
Release 3.1.4.5
New PowerConnect 8024 Switch
A 24 port 10GBase-T (1Gigabit/10Gigabit) switch with 20 fixed 10GBase-T ports and 4 combo ports that
can be either 10GBase-T or SFP/SFP+. There are two redundant power supplies each of which can supply
300W. For management there is one RS232 console port and an OOB port.
Fiber ports support 1Gigabit and 10Gigabit Transceivers
The PC8024/PC8024F support 1Gigabit SFP and 10Gigabit SFP+ transceivers on fiber ports. The following
table explains the supported transceivers and their capabilities on fiber ports.
Module Type
Negotiation Support
Default Negotiation
Supported Speeds
SFP
Yes
Enabled
1G
SFP+
No
Not Applicable
10G
RTAG7 Hashing Mode Support
Port Channels now can use the RTAG7 hashing support for improved load sharing.
There are several configurable RTAG7 options such as packet field selection, source and destination port
numbers, XOR and CRC algorithms, and modulo operation. The RTAG7 settings apply to both Trunk
hashing and ECMP hashing. There cannot be 2 different RTAG7 settings for LAGs and ECMP.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 5
ReFormatFLASHFileSystem
There is now a file system recovery option that is present in the boot menu that users can use if they
suspect an issue with the file system on a switch. This option will copy the minimum required files from
the file system, reformat the file system, and copy the files back.
Changed Functionality in this Release
Release 3.1.4.16
No changes in functionality for Release 3.1.4.16.
Release 3.1.4.8
No changes in functionality for Release 3.1.4.8.
Release 3.1.4.5
VLAN Limit Increases
MAC based VLAN limit was increased from 128 to 256.
Subnet based VLAN limit was increased from 64 to 128.
Layer 2 Multicast Group
The Layer 2 Multicast Group limit was increased from 1K to 2K.
ISDP Advertise/Display hostname
ISDP can now use the hostname as the Device ID instead of the Serial Number. The user needs
to change the default hostname on the switch and can verify the results via the show isdp
command.
PowerConnect 8024/8024F Release Notes
Page 6
System Firmware Version 3.1.4.16
Issues Resolved
Release 3.1.4.16
Description
User Impact
Resolution
In simple mode STP BPDU will pass
through from one port-aggregator to
the other port-aggregator
Switches receiving unwanted STP
BPDUs may shut the port down.
BPDU flooding set to disabled in
simple mode by default.
Switch is crashing when it is
connected to a CDP enabled CISCO
6509
The CISCO 6509 sends CDP PDUs
that are larger than expected which
can occasionally result in a switch
reboot.
Updated the local buffer to be
tolerant of larger packet sizes.
Interface metric not working on OSPF
passive interface.
When an OSPF interface is
configured as Passive, 8024F
advertises the interface metric (cost)
as 0, irrespective of cost configured.
Corrected to generate the proper
interface cost.
Displaying the wrong LACP system
MAC address in "show lacp port-
channel".
The incorrect MAC address was
shown for the partner switch in "show
lacp port-channel" CLI command
output.
Corrected to retrieve the proper
MAC address.
SNMP Agent becoming unresponsive.
The switch will stop responding to
SNMP requests.
A semaphore now used to properly
control SNMP and CLI access to
common configuration data
structures.
TX DMA will timeout and cause the
switch to reboot.
The stack crashes with a crash dump
from the workQAdd2 task.
Corrected a heap memory
fragmentation problem when
processing DMA transactions.
H323 VoIP traffic crashes the switch
VoIP task processing was not allowing
other tasks to run causing a stalled
task to reboot the switch.
VoIP packets are not sent to the
switch CPU if the auto-VoIP feature
is administratively disabled.
LACP not working with Juniper EX-
4200 when supporting Non-Stop
Forwarding
The LAG will not establish because all
the LACP data units are dropped.
Dropped LACP data units were
caused by an incorrect packet
length. The packet length of 132
was changed to 128 in order to
conform to the standard.
Invalid SNMP query result on walking
ipAdEntNetMask.
Secondary Netmask configuration is
not displayed for an interface IP
Address, and the Netmask of the
primary IP Address is shown instead.
Changed the implementation of
ipmIpAdEntNetMaskGet to also take
the address parameter and look up
the specific Netmask.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 7
Description
User Impact
Resolution
The show ip igmp groups vlan detail
does not show any registered MC
groups.
Only detail fails to show registered
MC groups. Other commands show
the groups correctly.
Corrected the show ip igmp groups
detail command.
Release 3.1.4.8
Description
User Impact
Resolution
Occasionally, the switch will stop
responding to SNMP
The switch will become unresponsive
with the message ”Timeout: No
Response from AA.BB.CC.DD.”
Semaphores were added to protect
data from becoming corrupted.
Release 3.1.4.5
Description
User Impact
Resolution
IGMP Querier does not work if IP
Multicast not enabled.
User must enable IP multicast in order
for IGMP Querier to function properly.
Automatically enable IP Multicast
when IGMP is enabled.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
The driver modified to handle MAC
addresses correctly to prevent the
log messages.
Radius Servers always show active
status.
The RADIUS Server Status web page
was always displaying the server’s
status as active.
Retrieved the server status the
same as the CLI for each row in the
web page display.
PFC frames received per priority
queue are always shown as zero.
Per priority PFC frames received
count is always zero.
PFC frames statistics are not
properly reported.
productIdentificationPerUnitTable OID
was re-numbered when banner OIDs
were inserted.
Management applications that use the
OID in the 3.1.1.9 release will not
work properly.
Reverted the OID to the proper
value used on the other
PowerConnect switches.
BPDU protection fails when port is in
dot1x un-authorized state.
When the port is in Dot1x
Unauthorized mode STP bpdus will
not be allowed to the Dot1s
application and increase CPU
utilization.
Allow STP BPDUs without
considering the dot1x authorized
state of the port.
Code Download is getting failed with
HTTPs as management session and
downloading protocol as HTTP.
Code Download is getting failed with
HTTPs as management session and
downloading protocol as HTTP.
Pass correct file path when HTTP is
selected as the download method.
Service Port MAC address is not valid
The OOB port is not using the correct
MAC address, even though the output
of "show ip interface out-of-band"
shows the correct MAC address.
Initialized driver to properly process
the MAC Address.
PowerConnect 8024/8024F Release Notes
Page 8
System Firmware Version 3.1.4.16
Description
User Impact
Resolution
Switch throws errors of level
info/debug when clearing PFC
interface counters or checking PFC
interface counters.
Error messages are displayed on the
console and the counters not
incremented properly due to
misintepreted failure conditions.
Now counters are properly handled
based on the applicable registers.
Switch uploads startup-config when
tried uploading running-config.
Running-config cannot be uploaded
from web.
Corrected algorithm to determine
proper file type to upload.
PFC counters on LAG interface are
not incrementing.
Error messages are displayed on the
console and the counters not
incremented properly due to
misinterpreted failure conditions.
Now counters are properly handled
based on the applicable registers.
Summer Time enabled does not
reflect correctly in the output of 'show
running-config' and 'show clock detail'.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Recurring Summer Time is getting
configured for max offset value even
though offset is not configured.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Location information is not found in
CLI / Web when Recurring Summer
Time is configured.
show commands do not reflect the
correct status, when summer-time for
EU or USA is configured.
Detect when the configuration
matches those modes to allow user
to identify what mode was selected.
Summer Time does not work when
date falls under configured window.
When summer time is configured, the
time reported is incorrect.
Updated the algorithm to correctly
calculate the summer-time period.
Web does not show starting / ending
month & year for non-recurring
summer time configuration.
The Start Month and Year, End Month
and Year fields were missing in the
Clock Detail Web page.
Added missing fields to the web
page
IGMP Queriers are sent out from the
switch after the pre-configured 60
secs interval
Partner would receive IGMP querier
packets later than the expected time,
even though the delay is neglected.
Updated cpu utilization mechanism
along with using accurate values for
system clock.
Summer Time offset range is not
correct.
User is allowed to configure out of
range values from the web page.
Corrected help string along with field
validations.
Failed to delete configured radius
server key
Radius server key cannot be deleted
once it's configured
Added no command support for
deleting key from Radius
configuration mode.
Upgrade PHY firmware to version
1.4.1.0
10G copper ports may take 2-5
minutes to link-up.
Switches automatically upgrade the
PHY firmware that corrects link up
time.
Switch is accepting any letter other
than "y" to generate SSH key.
Switch generates SSH key on
entering anything other than 'n' letter,
even though help is saying that it
allows only 'y' or 'n'.
Modified validation to not allow
anything other than 'y'/'n'
No button is selected by default in the
copy file web page
No button is selected by default in the
copy file web page
Modified web page to have a default
selection.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 9
Description
User Impact
Resolution
MLD Packets are not snooped, when
sending MLD packets with Hop-by-
Hop header with Router Alert Option.
Switch limitation such that it cannot
properly identify IPv6 MLD packets
that have the hop-by-hop option set.
Added a new MLD rule to the FFP
which will trap to the CPU IPv6
Membership reports which use the
well known MAC address
33:33:00:00:00:16.
Bridge multicast forbidden forward-
unregistered causes L3 Multicast to
fail.
Flooding in ingress VLAN.
Modified the L3 interaction code of
snooping to notify the driver when
snooping is enabled. When
snooping is disabled, the current
operational state of snooping is also
sent to the driver.
Show interfaces advertise ethernet
command is not parsed
properly.
No error message is printed if
Improved validation for invalid
interface.
'show interfaces switchport ethernet'
displays Egress Rule as "------" for
dynamic VLAN's.
Dynamic vlan is learned correctly. But
the show command "show interfaces
switchport ethernet "
command displays the dashed line in
place of participation strings when an
interface is participated in a dynamic
vlan.
Using different API to retrieve
tagging configuration of dynamic
vlan's versus static vlan's.
User can not configure protocol based
vlans on lag interfaces.
User can not configure protocol based
vlans on lag interfaces.
Updated to also allow protocol
based vlan's on LAG interfaces.
FDB entries are not getting deleted on
MAB enabled port when the dotx state
is changed to force unauthorization
The client MAC Address is still
present in the Forwarding Database
upon the Dot1x state change.
Corrected logic to clear FDB table
on setting the port state to force un-
authorized.
User with read-write access and with
enable authentication set as None is
not allowed to enter in to priviledge
mode.
User is unable to login enable mode
when authentication method is none.
Corrected retreiving of user access
based on the username and index.
Switch crashed when trying to
authenticate the Client using MAB
The switch reboots.
Modified driver layer to use a
semaphore to access the VLAN
shared data.
Device crashes when enabling
Dynamic Arp Inspection and
DHCPSnooping on out of range VLAN
Id.
The switch reboots.
Corrected the validation for the valid
VLAN ID range in the Dynamic Arp
Inspection an DHCP Snooping
feature.
IP Source Guard commands are not
available in port-channel mode
Cannot configure IP Source Guard on
port-channel interface via CLI.
Addeed IP Source Guard CLI
commands for port-channel mode.
Ports fail to participate in GVRP VLAN
on receiving GVRP packet, even
though VLAN gets created.
GVRP registrations are not occurring.
Synchronization between vlan
creation and vlan member
participation is addressed.
Configured radius accounting
attributes do not reflect in running-
config.
Accounting Server name not
displayed in the running config.
Updated running config to show
configured radius accouting
attributes.
PowerConnect 8024/8024F Release Notes
Page 10
System Firmware Version 3.1.4.16
Description
User Impact
Resolution
Read-write user gets Read-only
access for telnet and SSH session,
when authentication method is
RADIUS.
Read-write user gets Read-only
access for telnet and SSH session,
when authentication method is
RADIUS.
Use access level assigned by the
radius server instead of getting from
the local user database.
Traffic matching with COS 7 is getting
dropped, when inbound MAC ACL is
configured on the interface with vlan
priority as 7.
Traffic matching with COS 7 is getting
dropped, when inbound MAC ACL is
configured on the interface with vlan
priority as 7.
Corrected logic that configures vlan
priority as 6, when user is trying to
configure priority 7.
Switch crashes when File System
page is accessed after configuring file
descriptor through CLI with more than
128 characters length.
The switch reboots.
Increased buffer size to be 256.
Configured non-existing host cannot
be deleted for logging syslog
Only valid servers could be deleted by
the user.
Updated logic to remove non-
existing hosts also in CLI command
handler.
Able to successfully configure Banner
MOTD from WEB, but unable to
disable successfully.
Able to successfully configure Banner
MOTD from WEB, but unable to
disable successfully.
Added a checkbox in the web page
that to enable/disable MOTD
message.
Local user database does not accept
a user without a password from web,
although password minimum length is
disabled.
The Web would not accept the
username without a password which
was inconsistent with the CLI.
Changed the text box property to
allow empty password also.
UDP data is not received by the
mrouter interface at egress vlan even
though L2 MFDB table showing both
join registered interface and mrouter
interface
Querier attached interfaces will not
receive mcast data traffic
Add support for interfaces on which
queries are recevied.
Observed Internal BRCM_escape_lt;
brBRCM_escape_gt; words are
displayed on clicking Route
Redistribution Summary web page
Irrelevant text displayed on the web
page.
Modified object handler code to
interpret html tags correctly.
Out Of Band Port status is shown as
UP, even though it's shutdown.
Incorrect status communicated to the
user.
Update the status in PHY, when
service port is shutdown
Huge running-config display hogs up
screen space with downloaded image
for captive poral
It's an inconvienence to the CLI user
for the need to scroll past unreadable
data.
Remove all encoded binary and
Unicode from "show running-config".
Show encoded binary and Unicode
for show scripts (and show all)
commands.
Precede encoded binary and
Unicode with user notification
indiciating unreadable data.
Most encoded binary and Unicode
to the END of the show scripts (and
show all) command output.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 11
Description
User Impact
Resolution
guest-vlan-timeout' command is
missing from CLI.
User cannot configure the guest-vlan-
timeout period. Since the default
timeout is 30 sec's, this may be too
long before host is put into the guest
VLAN causing such issues as DHCP
clients’ timeouts waiting for DHCP
ACK's.
Added the new CLI command.
System LED state/color is not correct.
System LED does not indicate if both
images are invalid or one of the
fan/power module reports failure or
system temperate exceeds threshold.
Modified system LED algorithm to
reflect the correct status.
Switch is accepting IGMPv2 Joins
with TTL as 64.
Multicast traffic may get forwarded to
the unwanted user.
Added additional checks in packet
Rx process.
Static IP cannot be configured from
WEB
Static IP cannot be configured from
WEB, as session is getting lost as
soon as the protocol is set to None.
Corrected dependencies in web to
allow confirmation of static IP from
Web.
Switch hangs when invalid image is
downloaded into script
Switch hangs when invalid image is
downloaded into script
Added a check to raise an error if a
downloaded script file is binary or if
it does not contain any commands.
IGMP Querier does not work if IP
Multicast not enabled.
User must enable IP multicast in order
for IGMP Querier to work.
Automatically enable IP Multicast
when IGMP is enabled.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
Sending multiple DHCP discoveries to
the switch results in log messages on
the console.
Driver modified to handle MAC
addresses correctly.
Radius Servers always show active
status.
The RADIUS Server Status web page
was always displaying the server’s
status as active.
Retrieved the server status the
same as the CLI for each row in the
web page display.
Interface Configuration web page
would not allow the user to set the
MTU size to zero.
Interface Configuration web page
restricted the user to configure the IP
MTU from 68-9198.
Changed the weg page IP MTI field
do allow the following values to be
configured: 0 or 68-9198.
Missing RFC1213 MIB-2 SNMP Trap
counter
System did not provide values for mib-
2, snmp, snmpOutTraps (Oid
.1.3.6.1.2.1.11.29).
Re-enabled objects to provide
support even though they are
obsolete in RFC-1907.
PowerConnect 8024/8024F Release Notes
Page 12
System Firmware Version 3.1.4.16
Known Restrictions and Limitations
Interfaces
Ports
Description
User Impact
10GBaseT ports operating at speeds
lower than 10G must have both Flow
Control and Priority Flow Control
enabled in hardware. As a result, when
showing the interface status, Flow
Control will show active on interfaces
enabled for Priority Flow Control.
This is automatically enabled when the user enables Priority Flow
Control.
When using Priority Flow Control, the
dot1p-mapping to traffic class must be
one-to-one. For example, dot1p value 0
must be mapped to traffic class 0, and
dot1p value 1 must be mapped to traffic
class 1.
If this is not done, the wrong queue may be suspended when priority
flow control frames are received.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 13
Layer 2
802.1AB (LLDP)
Description
User Impact
TLV Information is flushed as soon as
power to the link partner is
disconnected.
The remote information that should age out in 120 seconds will age out
when the port loses link. Currently no application features use these
entries. It is just information that is displayed.
LLDP-MED location and inventory
transmit TLVs have no effect.
The switch does not support configuring this data so enabling these
TLVs has no effect.
802.1X
Description
User Impact
Windows Vista® Authentication
The Windows Vista® client will fail to authenticate properly on subsequent
connections when the option to cache user credentials is selected.
Workaround:
1.
In Control Panel Network Connections, right-click on the
desired Local Area Connection and select Properties.
2.
In the Properties window, select the Authentication tab.
3.
Deselect the checkbox for Cache user information for
subsequent connections to this network.
4.
Click OK.
RSTP blocked ports reporting
Blocked STP ports will not show in the CLI command show spanning-tree
blocked ports.
802.1X clients MAC do not appear in
the bridge address table.
Customers cannot see the authenticated clients MAC addresses in the
Forwarding Database but have to dump via show dot2x commands which
do not show a summarized table.
VLAN
Description
User Impact
vlan association mac command
limitations
The maximum number of MAC-based VLANs is 256.
Spanning Tree
Description
User Impact
STP Topology change Notification
count is not showing in log
messages.
Log messages do not contain the topology count which is minimal impact.
PowerConnect 8024/8024F Release Notes
Page 14
System Firmware Version 3.1.4.16
DHCP Snooping
Description
User Impact
DHCP client packets received on
trusted ports are forwarded onto
untrusted ports.
If another Client is receiving the flooded packet on an untrusted port,
there is no impact.
If a Server on the untrusted port receives this flooded packet and
responds to it with OFFER, which would be dropped by the Snooping
application.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 15
Layer 3
IP Map
Description
User Impact
"ip default gateway" and "ip default
route" are for different types of
interfaces. "ip default gateway" is for
the in-band and out-of-band
management interface and "ip default
route" is for VLAN routing interfaces.
Ensure the correct command is used for the interface being configured.
ICMP
Description
User Impact
IPv4 Fragmentation support.
The switch is not fragmenting the
datagram and forwards even when
the IP MTU of the forwarding
Interface is set to a lower value (than
the datagram size).
If a packet is sent to the switch and it exceeds the IP MTU, but the packet
is smaller than the link MTU then the packet is not fragmented but is
silently discarded. An ICMP error message is not sent to the sender.
ICMP Error message generation.
The ICMP Error Message generated
by the switch has the fields (TTL)
unmodified instead of sending with a
modified value resulted as a part of
forwarding process.
No significant impact to the user since the TTL field, which is not
decremented, is in the packet contained in the error message.
ICMPv6 Packet Too Big
If a packet is sent to the switch and it exceeds the IPv6 MTU, but the
packet is smaller than the link MTU then the packet is not fragmented but
is silently discarded. An ICMP error message is not sent to the sender.
Multicast
Description
User Impact
DVMRP will drop packets under high
loads.
DVMRP functionality works fine and such issues are not seen in 2 or 3
router topologies. This issue is seen only in complex topologies under
high loads in the presence of other multicast entries upon table full
conditions.
Routing
Description
User Impact
Routable interface ping times.
The ping latency is highly variable on routable interfaces.
IS-IS tagged traffic will change to
IS-IS packets are always forwarded untagged, regardless of the port’s
PowerConnect 8024/8024F Release Notes
Page 16
System Firmware Version 3.1.4.16
untagged packet.
tagging configuration.
PowerConnect 8024/8024F Release Notes
System Firmware Version 3.1.4.16
Page 17
Management
CLI
Description
User Impact
The CLI does not support the ability
to download RSA or DSA keys or
certificates.
The user can perform this download via the web management interface.
SNMP
Description
User Impact
Not able to set the value for
dellLanMngInfEnable
Management ACLs are always enabled and cannot be disabled.
dot3StatsAlignmentErrors not
incrementing
The value for all ports shows up as 0.
agentStpPortRootGuard object has
been obsoleted.
Use agentStpCstPortRootGuard instead.
SNMP causing crash.
The switch will crash under heavy simultaneous RMON and SNMP
transaction loads.
Web-based Management
Description
User Impact
Traffic Monitoring Chart Rate display
not valid.
The chart displays a count rather than a rate.
Browser-specific issue: Submitting a
page in IE6 multiple times before the
switch has responded may cause the
browser to hang.
Wait for the response from the switch before pressing other buttons on
the page.
Browser-specific issue: On the VRRP
Router Configuration page, the
authentication type is not saved when
using Firefox v2.x.
To configure the authentication type, either upgrade the browser to
Firefox 3.x or use the CLI.
Web UI shows incorrect available
memory (off by 3 decimal places)
The user will have to get the actual available memory from the CLI.
User can not configure protocol
based vlans on lag interfaces via the
web interface.
User can use the CLI to configure Protocol VLAN on a port channel.
PowerConnect 8024/8024F Release Notes
Page 18
System Firmware Version 3.1.4.16
Cable Diagnostics
Description
User Impact
Time is reported as UTC and not
local time in log files and CLI for
copper ports.
The times are not adjusted for the local time zone.
Issues with show fiber-ports optical-
transceiver output.
The port is enabled when the fiber diagnostics are run. Because of this,
the user sees the same diagnostics for both port up and down. There is
also an invalid value that shows in power out.
Management ACL
Description
User Impact
Management ACL is not working for
Out-Of-Band interface
Management ACLs are not implemented on the Out-Of-Band interface.
SNTP
Description
User Impact
Too many SNTP messages in log file.
The log can fill up with informational message of SNTP: system clock
synchronized. Change Log message from notice level to NTP debug
level in order to avoid the additional messages.
User Manager
Description
User Impact
A user that configures a User Level
15 and disables the RADIUS
authentication server may not be able
to login.
When the radius server does not exist and the authentication fails, the
next authentication method is not getting invoked.
End of Release Notes