Text of the manual

Mobile DC to AC power inverters with battery charger

User’s manual Design Features • Switch mode design. • Compact design. • Complete protection design. • Inverter re-start function. • 3-stage charger design. • Wide volt range operation. • Durable and corrosion resistant construction. • Transformer isolated for safety. • By pass function. • Emergency backup light (LED) function • One more DC terminal to connect battery or solar panel • Max. 100Ah battery space. • With USB power port. List of contents 1. Important safety instructions .........................................................................1 2. Where to install ..............................................................................................1 3. Batteries ..........................................................................................................2 4. Charging time ..................................................................................................3 5. Features ..........................................................................................................3 6. Specifications ..................................................................................................4 7. Battery charger ...............................................................................................5 8. Troubleshooting guide ....................................................................................7 9. Warranty .........................................................................................................7

Important safety instructions

WARNING Before you install and use your inverter, be sure to read and save these safety instructions General safety precautions Do not expose the inverter to rain, snow, spray, bilge or dust. To reduce risk of hazards, do not cover or obstruct the ventilation openings. Do not install the inverter in a zero-clearance compartment. Overheating may result. To avoid a risk of fire and electric shock make sure that existing wiring is in good electrical conditions and the wire size isn’t undersized. Do not operate the inverter with damage or substandard wiring. This equipment is not ignition protected and employs components that tend to produce arcs or sparks. To reduce the risk of fire or explosions, do not install in compartments containing batteries or flammable materials or areas in which ignition protected equipment is required. Never smoke or allow a spark or flame in vicinity of battery or engine. Not installing a fuse can result in fire that may cause injuries and/or damages. You may observe a spark when making the cable connections since current may flow and charge capacitors in the inverter. This is normal. Do not make cable connections in the presence of flammable fumes; it may result in explosion and/or fire. Shock Hazard. Before proceeding further, carefully check the inverter is not connected to any batteries, and that all wiring is disconnect from any electrical sources. Do not connect the output terminals of the inverter to an incoming AC source. Risk of electrical shock. Do not remove cover, no user serviceable parts inside. Refer servicing to qualified service personnel. 2. Where to install Your inverter should be installed in a location that meets the following requirements: Dry: keep the inverter away from any water or moisture. Cool: Ambient air temperature should be between 0ºC y 40ºC (32ºF and 104ºF) Ventilated: Ensure that the unit is located in a well ventilated compartment. At least 15cm (6 inches) of clearance are required around the inverter for air flow. Verify that all ventilation openings on the unit (front and rear panels) are not obstructed. User’s manual - 1 - PDATROLY-1000

Don't reverse the (+) and (-) of the battery, or internal damage will cause.

''Damage caused by reversed polarity is not covered by the warranty.'' 3. Batteries To achieve 50% cycling you should calculate your amp-hour consumption between charging cycles and use a battery bank with twice that capoacity. To calculate Amp-hour consumption, fisrt look at the rating plate on your AC appliance or tools. Each appliance or toll will be rated in either AC amps or AC watt or AC VA(volt-amperes) apparent power. Use one of the following to calculate the DC amp-hour draw for a 12V system. (AC amps x 19.1 if mains is 230VAC) x 1.1 x hours of operation = DC amp-hours. (AC watts/12) x 1.1 x hours of operation = DC amp-hours. (AC VA/12) x 1.1 x hours of operation = DC amp-hours. In all formulas, 1.1 is the factor for inverter/charger efficiency. Calculate the above for every AC appliance or tool you intend to use on your inverter. This will give you the total number of amp-hours used between recharges. Size your battery bank using this number as a guideline. A good rule to follow is to size the battery bank about two times mlarger than your total amp-hour load requirement. Plan on recharging when 50% discharged. Many electrical motors have momentary starting requirements weel above their operational rating. Start up watts are listed where appropiate. Individual styles and brands of appliance may vary. NOTICE: The output of this device is not pure sine wave, but modified sine wave (1) Small Load Inverter LED Indicator : Green. (2) Half Load Inverter LED Indicator : Orange. (3) Full Load Inverter LED Indicator : Red. User’s manual - 2 - PDATROLY-1000 Battery + - Velcro belt to fix the battery Connect to battery ( + : red / - : black)

Formula: Charging time will depend on the capacity oy your battery and on how deeply is

discharged. The following equation calculates an approximate charging time: Charging time = CAP x DOD CC x 80% Where: Charging time: battery recharge time in hours. CAP: Battery capacity in ampere-hours DOD: Battery depth of discharge in per cent. A fully discharged battery has a 100% DOD. CC: Charge current, the rated current output of the charger in amperes 80%: Typical charging efficiency fo lead-acid batteries. Example: A group size battery rated at 100 amp-hours is 40% discarged, that is it has a DOD = 40. Carging time with the charger of a PDATROLY-1000 is calculated as follows: Charging time = 100Ah x 40% = 5 hours 10A x 80% 5. Features (1) A Movable power system --- Modified sine wave inverter with 3-stage 10A battery charger. (2) Switch mode design. (3) Compact and dexterous dimension design. (4) Complete protection design --- overload, overtemp, short circuit, high/low volt ... etc. (5) Inverter re-start function. (6) 3-stage charger design --- bulk, absorption, float. (7) Wide volt range operation (180~265V) (8) Durable and corrosion resistant construction. (9) Transformer isolated for safety. (10) By pass function. (11) Emergency backup light (LED) function. (12) One more DC terminal to connect battery or solar panel (Solar charger controller as intermediary suggested). (13) Max. 100Ah battery space. (14) With USB power port. User’s manual - 3 - PDATROLY-1000

DC input voltage

12VDC DC input voltage range 10~16VDC Surge power 2000W Continuous power 1000W Wave form Modified sine wave AC output voltage 230VAC User’s manual - 4 - PDATROLY-1000 (Front view) Inverter ON Charger AC IN USB Port Battery Volt & Charger Step 14V 13V 12V 11V 10V(Fault) Charger Step 40% graph flash Bulk: Absorption: 60% graph flash Flat: 100% graph flash Fault (red): No battery, low input volt, charger overtemp.. (Side view) 1 1 2 2 1. DC Terminal 2. Thermal cooling fan 3. ON/OFF Switch 4. Inverter Indicator 5. Breaker 6. 7. Inverter / AC Output Receptacle - With AC IN power - OFF - With Battery Power ( AC Power is failed ) Light Switch 1. Emergecy Light 2. 6 7 3 4 5 . Charge AC Input Port

50Hz ± 3%

AC regulation ± 8% No load current draw 0.6A Battery low alarm 10.5 ± 0.5VDC Battery low shutdown 10 ± 0.5VDC Overvoltage 16 ± 0.5VDC Battery polarity reverse Fuse burn out Overload Re-start 2 times, shutdown if failed By-pass function Yes CHARGER Output current 10A AC input voltage 180~265VAC Charging type 3 stage Bulk stage 14.5 ± 0.5VDC, 10A Absortion stage 14.5 ± 0.5VDC, 10~1A Float stage 13.6 ± 0.5VDC, minimum 0.5A Frequency 45~65Hz Recommended battery type Lead acid Recommended battery size 40~160Ah DC power supply (fixed output) mode 12.5VDC PROTECTION Overload protection Yes Overtemperature protection Yes Inverter output reverse protection Fuse blow Charger output reverse protection Fuse blow Inverter short-circuit protection Shut-off Overtemperature 55 ± 5ºC Dimension (LxWxH) 455 x 390 x 340 Net weight 9.5Kg (without battery) Gross weight 10.5Kg (without battery) Specifications subject to change without notice 7. Battery charger For lead-acid and lead-calcium, lithium-iron batteries only. Stage 1: Bulk Charge Max 14.5±0.5V, 10A. Charger LED Indicator: Red. Stage 2: Absorption Charge 14.5±0.5V, 10~1A. Charger LED Indicator: Red. Stage 3: Float Charge 13.6±0.5V, min. 0.5A. Charger LED Indicator: Orange. Complete charging, charger LED Indicator: Green. User’s manual - 5 - PDATROLY-1000

3 short alarm

- Overload - Short circuit - Reduce load - Solve short circuit Orange flash Long alarm - Low battery shut down - Hightemp shut down - Replace or charge the battery - Allow inverter/charger to cool off. Improve ventilation. Green flash Quick alarm - Low battery - Poor DC wiring - Poor DC terminal connection. - Charge or change battery - Improve DC wiring - Improve DC terminal connection No Inverter LED None High battery shut down Reduce input volt Charger Mode Charger LED Alarm Question Solution Red flash, (output 2-3A only) None Hightemp Allow device to cool off. Improve ventilation. User’s manual - 6 - PDATROLY-1000 3-Stage Battery Charger DC Voltage DC Current Charging started Bulk stage Constant current at maximum charge rate Absorption stage Constant voltage at Absorption voltage setting Float stage Constant voltage at the Float voltage setting Load current on demand Charger LED indicator Red Red Orange Time :

Things to check

No invertir output 1. Battery voltage under load 2. Battery connections and DC fuse 3. Circuit breaker on front panel 4. Thermal condition, high powered loads or inadequate ventilation may cause overheating 5. Overloads or chort circuit, check for excessive loads or bad wiring connections Low inverter output voltage Confirm that your volt meter is a true RMS meter. Standard volt meters will no accurately read the waveform odf the inverter. If a true RMS meter is not available, check the brightness of an incandescen light bulb. If it appears normal, the output voltage is properly regulated. Little or no output from battery charger 1. Wiring connections-check both the AC and DC connections. 2. AC input voltage-low voltage input will result in low DC output current. 3. AC input spec. isn't correct to Inverter/Charger spec. V2 01/2013 9. Warranty We offer 12 months warranty from the date of purchase, as stated in invoice or purchasing proof, and will repair or replace any defective power invertir. This limited warranty is void if the unit is abused, modified, installed improperly, if the housing has been removed, if the serial number is missing, or if the original identification markings have been defaced, altered, or removed The supplier is not liable for any incidental, consequential or other damages arising from the use, cost of removal, installation, or troubleshooting of the customer's electrical systems. Repair or replacement are your sole remedies and shall not be liable for damages, whether direct, incidental, special or consequential, even though cause by negligence or other fault. This is only warranty and the company makes no other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. User’s manual - 7 - PDATROLY-1000