Fullwat PDATROLY-1000 Operation & User’s Manual
Read Online
Read the Fullwat PDATROLY-1000 Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Mobile DC to AC power inverters with battery charger
User’s manual
Design Features
•
Switch mode design.
•
Compact design.
•
Complete protection design.
•
Inverter re-start function.
•
3-stage charger design.
•
Wide volt range operation.
•
Durable and corrosion resistant construction.
•
Transformer isolated for safety.
•
By pass function.
•
Emergency backup light (LED) function
•
One more DC terminal to connect battery or solar panel
•
Max. 100Ah battery space.
•
With USB power port.
List of contents
1.
Important safety instructions .........................................................................1
2.
Where to install ..............................................................................................1
3.
Batteries ..........................................................................................................2
4.
Charging time ..................................................................................................3
5.
Features ..........................................................................................................3
6.
Specifications ..................................................................................................4
7.
Battery charger ...............................................................................................5
8.
Troubleshooting guide ....................................................................................7
9.
Warranty .........................................................................................................7
Important safety instructions
WARNING
Before you install and use your inverter, be sure to read
and save these safety instructions
General safety precautions
Do not expose the inverter to rain, snow, spray, bilge or dust. To reduce risk of hazards, do not
cover or obstruct the ventilation openings. Do not install the inverter in a zero-clearance
compartment. Overheating may result.
To avoid a risk of fire and electric shock make sure that existing wiring is in good electrical
conditions and the wire size isn’t undersized. Do not operate the inverter with damage or
substandard wiring.
This equipment is not ignition protected and employs components that tend to produce arcs
or sparks. To reduce the risk of fire or explosions, do not install in compartments containing
batteries or flammable materials or areas in which ignition protected equipment is required.
Never smoke or allow a spark or flame in vicinity of battery or engine.
Not installing a fuse can result in fire that may cause injuries and/or damages.
You may observe a spark when making the cable connections since current may flow and
charge capacitors in the inverter. This is normal. Do not make cable connections in the
presence of flammable fumes; it may result in explosion and/or fire.
Shock Hazard. Before proceeding further, carefully check the inverter is not connected to any
batteries, and that all wiring is disconnect from any electrical sources. Do not connect the
output terminals of the inverter to an incoming AC source.
Risk of electrical shock. Do not remove cover, no user serviceable parts inside. Refer servicing
to qualified service personnel.
2.
Where to install
Your inverter should be installed in a location that meets the following requirements:
Dry: keep the inverter away from any water or moisture.
Cool: Ambient air temperature should be between 0ºC y 40ºC (32ºF and 104ºF)
Ventilated: Ensure that the unit is located in a well ventilated compartment. At least 15cm (6
inches) of clearance are required around the inverter for air flow. Verify that all ventilation
openings on the unit (front and rear panels) are not obstructed.
User’s manual
- 1 -
PDATROLY-1000
Don't reverse the (+) and (-) of the battery, or internal damage will cause.
''Damage caused by reversed polarity is not covered by the warranty.''
3.
Batteries
To achieve 50% cycling you should calculate your amp-hour consumption between charging
cycles and use a battery bank with twice that capoacity. To calculate Amp-hour consumption,
fisrt look at the rating plate on your AC appliance or tools.
Each appliance or toll will be rated in either AC amps or AC watt or AC VA(volt-amperes)
apparent power.
Use one of the following to calculate the DC amp-hour draw for a 12V system.
(AC amps x 19.1 if mains is 230VAC) x 1.1 x hours of operation = DC amp-hours.
(AC watts/12) x 1.1 x hours of operation = DC amp-hours.
(AC VA/12) x 1.1 x hours of operation = DC amp-hours.
In all formulas, 1.1 is the factor for inverter/charger efficiency.
Calculate the above for every AC appliance or tool you intend to use on your inverter. This will
give you the total number of amp-hours used between recharges. Size your battery bank using
this number as a guideline. A good rule to follow is to size the battery bank about two times
mlarger than your total amp-hour load requirement. Plan on recharging when 50% discharged.
Many electrical motors have momentary starting requirements weel above their operational
rating. Start up watts are listed where appropiate. Individual styles and brands of appliance
may vary.
NOTICE:
The output of this device is not pure sine wave, but modified sine wave
(1) Small Load Inverter LED Indicator : Green.
(2) Half Load Inverter LED Indicator : Orange.
(3) Full Load Inverter LED Indicator : Red.
User’s manual
- 2 -
PDATROLY-1000
Battery
+
-
Velcro belt to fix the battery
Connect to battery ( + : red / - : black)
Formula: Charging time will depend on the capacity oy your battery and on how deeply is
discharged. The following equation calculates an approximate charging time:
Charging time =
CAP x DOD
CC x 80%
Where:
Charging time: battery recharge time in hours.
CAP:
Battery capacity in ampere-hours
DOD:
Battery depth of discharge in per cent. A fully discharged battery has a 100%
DOD.
CC:
Charge current, the rated current output of the charger in amperes
80%:
Typical charging efficiency fo lead-acid batteries.
Example:
A group size battery rated at 100 amp-hours is 40% discarged, that is it has a
DOD = 40. Carging time with the charger of a PDATROLY-1000 is calculated as
follows:
Charging time =
100Ah x 40%
= 5 hours
10A x 80%
5.
Features
(1) A Movable power system --- Modified sine wave inverter with 3-stage 10A battery
charger.
(2) Switch mode design.
(3) Compact and dexterous dimension design.
(4) Complete protection design --- overload, overtemp, short circuit, high/low volt ... etc.
(5) Inverter re-start function.
(6) 3-stage charger design --- bulk, absorption, float.
(7) Wide volt range operation (180~265V)
(8) Durable and corrosion resistant construction.
(9) Transformer isolated for safety.
(10) By pass function.
(11) Emergency backup light (LED) function.
(12) One more DC terminal to connect battery or solar panel (Solar charger controller as
intermediary suggested).
(13) Max. 100Ah battery space.
(14) With USB power port.
User’s manual
- 3 -
PDATROLY-1000
DC input voltage
12VDC
DC input voltage range
10~16VDC
Surge power
2000W
Continuous power
1000W
Wave form
Modified sine wave
AC output voltage
230VAC
User’s manual
- 4 -
PDATROLY-1000
(Front view)
Inverter ON
Charger
AC IN
USB Port
Battery Volt
&
Charger Step
14V
13V
12V
11V
10V(Fault)
Charger Step
40% graph flash
Bulk:
Absorption: 60% graph flash
Flat:
100% graph flash
Fault (red):
No battery, low input volt,
charger overtemp..
(Side view)
1
1
2
2
1. DC Terminal
2. Thermal cooling fan
3. ON/OFF Switch
4. Inverter Indicator
5. Breaker
6.
7. Inverter / AC Output
Receptacle
- With AC IN power
- OFF
- With Battery Power
( AC Power is failed )
Light Switch
1. Emergecy Light
2.
6
7
3 4
5
. Charge AC Input Port
50Hz ± 3%
AC regulation
± 8%
No load current draw
0.6A
Battery low alarm
10.5 ± 0.5VDC
Battery low shutdown
10 ± 0.5VDC
Overvoltage
16 ± 0.5VDC
Battery polarity reverse
Fuse burn out
Overload
Re-start 2 times, shutdown if failed
By-pass function
Yes
CHARGER
Output current
10A
AC input voltage
180~265VAC
Charging type
3 stage
Bulk stage
14.5 ± 0.5VDC, 10A
Absortion stage
14.5 ± 0.5VDC, 10~1A
Float stage
13.6 ± 0.5VDC, minimum 0.5A
Frequency
45~65Hz
Recommended battery type
Lead acid
Recommended battery size
40~160Ah
DC power supply (fixed output) mode
12.5VDC
PROTECTION
Overload protection
Yes
Overtemperature protection
Yes
Inverter output reverse protection
Fuse blow
Charger output reverse protection
Fuse blow
Inverter short-circuit protection
Shut-off
Overtemperature
55 ± 5ºC
Dimension (LxWxH)
455 x 390 x 340
Net weight
9.5Kg (without battery)
Gross weight
10.5Kg (without battery)
Specifications subject to change without notice
7.
Battery charger
For lead-acid and lead-calcium, lithium-iron batteries only.
Stage 1: Bulk Charge Max 14.5±0.5V, 10A. Charger LED Indicator: Red.
Stage 2: Absorption Charge 14.5±0.5V, 10~1A. Charger LED Indicator: Red.
Stage 3: Float Charge 13.6±0.5V, min. 0.5A. Charger LED Indicator: Orange.
Complete charging, charger LED Indicator: Green.
User’s manual
- 5 -
PDATROLY-1000
3 short alarm
- Overload
- Short circuit
- Reduce load
- Solve short circuit
Orange flash
Long alarm
- Low battery shut down
- Hightemp shut down
- Replace or charge the
battery
- Allow inverter/charger to
cool off. Improve
ventilation.
Green flash
Quick alarm
- Low battery
- Poor DC wiring
- Poor DC terminal connection.
- Charge or change battery
- Improve DC wiring
- Improve DC terminal
connection
No Inverter LED
None
High battery shut down
Reduce input volt
Charger Mode
Charger LED
Alarm
Question
Solution
Red flash,
(output 2-3A only)
None
Hightemp
Allow device to cool off.
Improve ventilation.
User’s manual
- 6 -
PDATROLY-1000
3-Stage Battery Charger
DC Voltage
DC Current
Charging started
Bulk stage
Constant current
at maximum
charge rate
Absorption stage
Constant voltage
at Absorption
voltage setting
Float stage
Constant voltage
at the Float
voltage setting
Load current on demand
Charger LED
indicator
Red
Red
Orange
Time :
Things to check
No invertir output
1.
Battery voltage under load
2.
Battery connections and DC fuse
3.
Circuit breaker on front panel
4.
Thermal condition, high powered loads or inadequate
ventilation may cause overheating
5.
Overloads or chort circuit, check for excessive loads or
bad wiring connections
Low inverter output voltage
Confirm that your volt meter is a true RMS meter.
Standard volt meters will no accurately read the waveform odf
the inverter.
If a true RMS meter is not available, check the brightness of an
incandescen light bulb. If it appears normal, the output voltage
is properly regulated.
Little or no output from
battery charger
1.
Wiring connections-check both the AC and DC
connections.
2.
AC input voltage-low voltage input will result in low DC
output current.
3.
AC input spec. isn't correct to Inverter/Charger spec.
V2 01/2013
9.
Warranty
We offer 12 months warranty from the date of purchase, as stated in invoice or purchasing
proof, and will repair or replace any defective power invertir.
This limited warranty is void if the unit is abused, modified, installed improperly, if the housing
has been removed, if the serial number is missing, or if the original identification markings
have been defaced, altered, or removed
The supplier is not liable for any incidental, consequential or other damages arising from the
use, cost of removal, installation, or troubleshooting of the customer's electrical systems.
Repair or replacement are your sole remedies and shall not be liable for damages, whether
direct, incidental, special or consequential, even though cause by negligence or other fault.
This is only warranty and the company makes no other warranties, express or implied,
including warranties of merchantability and fitness for a particular purpose.
User’s manual
- 7 -
PDATROLY-1000