Delta Electronics Network Device DOP-A/AE/AS Connection Manual
Read Online
Read the Delta Electronics Network Device DOP-A/AE/AS Connection Manual online using the built-in PDF viewer.
Text of the manual
Series HMI Connection Manual
ASIA
AMERICA
EUROPE
Delta Electronics, Inc.
Taoyuan1
31-1, Xingbang Road, Guishan Industrial Zone,
Taoyuan County 33370, Taiwan, R.O.C.
TEL: 886-3-362-6301 / FAX: 886-3-362-7267
Delta Electronics (Jiang Su) Ltd.
Wujiang Plant3
1688 Jiangxing East Road,
Wujiang Economy Development Zone,
Wujiang City, Jiang Su Province,
People's Republic of China (Post code: 215200)
TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290
Delta Electronics (Japan), Inc.
Tokyo Office
Delta Shibadaimon Building, 2-1-14 Shibadaimon,
Minato-Ku, Tokyo, 105-0012, Japan
TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211
Delta Electronics (Korea), Inc.
Donghwa B/D 3F, 235-6, Nonhyun-dong,
Kangnam-gu, Seoul 135-010, Korea
TEL: 82-2-515-5303/5 / FAX: 82-2-515-5302
Delta Electronics (Singapore) Pte. Ltd.
8 Kaki Bukit Road 2, #04-18 Ruby Warehouse Complex,
Singapore 417841
TEL: 65-6747-5155 / FAX: 65-6744-9228
Delta Products Corporation (USA)
Raleigh Office
P.O. Box 12173,5101 Davis Drive,
Research Triangle Park, NC 27709, U.S.A.
TEL: 1-919-767-3813 / FAX: 1-919-767-3939
Deltronics (The Netherlands) B.V.
Eindhoven Office
De Witbogt 15, 5652 AG Eindhoven, The Netherlands
TEL: 31-40-2592850 / FAX: 31-40-2592851
www.delta.com.tw/industrialautomation
*We reserve the right to change the information in this manual without prior notice
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 1
1.1
Pin Definition of Serial Communication
DOP-A Series
COM1
Mode
PIN
RS-232
1
N.C
2
RXD
3
TXD
4
N.C
5
GND
6
N.C
7
RTS
8
CTS
9
N.C
COM2
Mode 1
Mode 2
Mode 3
PIN
RS-232
RS-422
RS-485
1
N.C
RXD-
D-
2
RXD
RXD+
D+
3
TXD
TXD+
D+
4
N.C
TXD-
D-
5
GND
GND
GND
6
N.C
RTS-
N.C
7
RTS
RTS+
N.C
8
CTS
CTS+
N.C
9
N.C
CTS-
N.C
NOTE
1) Mode 3 is for RS-485. Pin 2 & 3 are D+ and pin 1 & 4 are D-.
2) Grounding is highly recommended if RS-485 & RS-422 are used for long transmission.
3) DO NOT connect Frame Ground (FGND) to GND. Please connect FGND to the outer covering of
connector.
4) Transmission speed is relevant to distance and baud rate.
Pin1
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-2
Revision January 2008 Doc Name: 2007PDD23000007
DOP-AE Series
COM1
Mode
PIN
RS-232
1
N.C
2
RXD
3
TXD
4
N.C
5
GND
6
N.C
7
RTS
8
CTS
9
N.C
COM2/COM3
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
PIN
RS-232
RS-422
RS-485
RS-232x2
RS-422x2
RS-485x2
1
N.C
RXD-
D-
N.C
RXD-
D-
2
RXD
RXD+
D+
RXD
RXD+
D+
3
TXD
TXD+
D+
TXD
TXD+
D+
4
N.C
TXD-
D-
N.C
TXD-
D-
COM2
5
GND
GND
GND
GND
GND
GND
6
N.C
RTS-
N.C
N.C
TXD-
D-
7
RTS
RTS+
N.C
TXD
TXD+
D+
8
CTS
CTS+
N.C
RXD
RXD+
D+
COM3
9
N.C
CTS-
N.C
N.C
RXD-
D-
Pin1
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 3
DOP AS Series
COM1/COM3
Mode 1
Mode 2
PIN
RS-232
RS-232x2
1
N.C
N.C
2
RXD
RXD
3
TXD
TXD
4
N.C
N.C
COM 1
5
GND
GND
6
N.C
N.C
7
RTS
TXD
8
CTS
RXD
COM 3
9
N.C
N.C
COM2
Mode 1
Mode 2
PIN
RS-422
RS-485
R-
RXD-
D-
R+
RXD+
D+
T-
TXD-
D-
T+
TXD+
D+
GND
GND
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-4
Revision January 2008 Doc Name: 2007PDD23000007
1.2
Cable for Download
Download via COM Port
RS-232
DOP series HMI
9 pin D-SUB male (RS-232)
PC
9 pin D-SUB female (RS-232)
Controller
RXD (2)
(3) TXD
TXD (3)
(2) RXD
GND (5)
(5) GND
RTS (7)
(8) CTS
CTS (8)
(7) RTS
上視圖
Download via USB Flash Drive
USB Connection
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 5
1.3
Supported Controllers and Devices
Please refer to the following table for supported controllers and devices provided by DOP series HMI.
Brand
Controller Name / Series Name
Delta Controller
For Servo/AC drive/Temperature Controller/PLC
(984 RTU mode / ASCII mode)
Delta
Delta DVP PLC
MicroLogix PLC
Allen Bradley
SLC5 PLC
Cimon
Loader Protocol
Copley
Servo (Stepnet Protocol)
Danfoss
VLT 2800 (FC Protocol)
Emerson
EC20 Series PLC
Facon
FB Series PLC
Festo
Festo PLC
GE Fanuc
90 Series SNP PLC
Hitachi
EH Series
Hust
Hust CNC Controller
Nano Series PLC
Jetter
JC Series PLC
Keyence
KV/KZ Series
SU/DL Series
Koyo
K-Sequence
Lenze
LECOM-A/B Protocol
Master-K120S/200S
Glofa GM6 CNET
Master-K CNET
LG
XGT CNET
LI YAN
LYPLC EX
M2i Master
M2i
M2i Slave
Matsushita
FP Series
Mirle
FAMA SC
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-6
Revision January 2008 Doc Name: 2007PDD23000007
Brand
Controller Name / Series Name
FX / FX2N
FX3U
A Series/J71UC24
Mitsubishi A2A/A2AS/A2USH A1SH/A3N/A2ASH CPU Port
Q Series CPU Port
Q Series Computer Link
FX Series Computer Link
Mitsubishi
J2s Series
BY125
CT150
MKS
MC700/720
Modbus (Master) --- 984 RTU / ASCII mode
Hexadecimal Address (Master) --- RTU / ASCII mode
nW (Master) --- RTU / ASCII mode
Modbus
Modbus (Slave) --- RTU / ASCII mode
Uni-Telway
TSX Micro
Modbus RTU
Modicon
TWIDO
Moeller
Moeller PLC
NIKKI DENSO
NCS-FI/FS Series
C Series
CJ1/CS1 Series
Omron
TPM1A
S7 200
S7-300 (with PC Adaptor)
Siemens
S7-300 (without PC Adaptor)
Taian
TP02 PLC
Vigor
M Series
VIPA
VIPA PLC
Yokogawa
ACE PLC
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 7
Delta (Servo/AC Drive/PLC/Temperature) Controller
Back to Table
A. HMI factory setting
Baud rate: ASCII: 9600, 7, None, 2.
RTU: 9600, 8. None, 2.
Controller station number: 1.
Control area/status area: None.
NOTE
1) This driver can support all Delta products, i.e. AC drive, PLC, Servo, Temperature Controller and
Modbus standard connection. The users can easily set and communicate with these devices via using
this driver.
2) For people who are using Modbus standard connection:
Modbus / ASCII (Master), Modbus / 984 RTU (Master), Modbus / ASCII Hex Address (Master) and
Modbus / RTU Hex Address (Master) can be compatible with the new Delta controller ASCII and Delta
controller RTU. To change the driver settings, the user only needs to change the “Controller” Option
which is used to set the controller, then the new driver can be used immediately.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Servo communication
address
SERVO-n
n: 0 ~ 0700h
N/A
Word
AC drive communication
address
INVERTER-n
n: 0 ~ 2299h
N/A
Word
TCntrl communication
address
TEMP_CTRL-n
n: 0 ~ 6000h
N/A
Word
WORD_DEVICE_X
PLC_Xn
n: 0 ~ 360(octal)
N/A
Word
WORD_DEVICE_Y
PLC_Yn
n: 0 ~ 360(octal)
N/A
Word
WORD_DEVICE_M
PLC_Mn
n: 0 ~ 1520,
N/A
Word
1536 ~ 4080
N/A
Word
WORD_DEVICE_S
PLC_Sn
n: 0 ~ 1008
N/A
Word
WORD_DEVICE_T
PLC_Tn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_C
PLC_Cn
n: 0 ~ 199
N/A
Word
WORD_DEVICE_D
PLC_Dn
n: 0 ~ 4095,
N/A
Word
4096 ~ 9999
N/A
Word
WORD_DEVICE_HC
PLC_HCn
n: 200 ~ 255
N/A
Double Word
PLC communication
address Module
PLC_Modulen
n: 4000 ~ 4499h
N/A
Word
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-8
Revision January 2008 Doc Name: 2007PDD23000007
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Output Registers
RW-n
n: 0 ~ FFFFh
N/A
Word
Input Registers
R-n
n: 0 ~ FFFFh
N/A
Word
Output Registers
Wn
n: 40001 ~ 50000
N/A
Word
Input Registers
Wn
n: 30001 ~ 40000
N/A
Word
NOTE
1) The above addresses of Servo, AC drive, Temperature controller and PLC Module are in hexadecimal
format. PLC Word Device X and Y are in octal format. Other PLC Word Device M, S, T, C, D and HC are
in decimal format.
2) WORD_DEVICE_ X / WORD_DEVICE_Y / WORD_DEVICE_M / WORD_DEVICE_S: Address must be
0 or the multiple of 16.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Servo communication address
SERVO-n.b
n: 0 ~ 0700h
b: 0 ~ f
AC drive communication address
INVERTER-n.b
n: 0 ~ 2299h
b: 0 ~ f
TCntrl communication address
TEMP_CTRL-n.b
n: 0 ~ 6000h
b: 0 ~ f
Servo Digital Input
SERVO_DI-n
N/A
n: 1 ~ 8
Servo Digital Output
SERVO_DO-n
N/A
n: 1 ~ 5
WORD_DEVICE_X
PLC_Xn
N/A
n: 0 ~ 377(octal)
WORD_DEVICE_Y
PLC_Yn
N/A
n: 0 ~ 377(octal)
WORD_DEVICE_M
PLC_Mn
N/A
n: 0 ~ 1535
1536 ~ 4095
WORD_DEVICE_S
PLC_Sn
N/A
n: 0 ~ 1023
WORD_DEVICE_T
PLC_Tn
N/A
n: 0 ~ 255
WORD_DEVICE_C
PLC_Cn
N/A
n: 0 ~ 255
TCntrl Bit communication address
TEMP_CTRLB-n
N/A
n: 800 ~ 8FFh
Discrete Outputs
RWB-n
N/A
n: 0 ~ FFFFh
Discrete Inputs
RB-n
N/A
n: 0 ~ FFFFh
Discrete Outputs
Bn
N/A
n: 1 ~ 10000
Discrete Inputs
Bn
N/A
n: 10001 ~ 20000
NOTE
1) The above addresses of Servo, AC drive, Temperature controller and PLC Module are in hexadecimal
format.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 9
2) PLC Word Device X and Y are in octal format. Other PLC Word Device M, S, T, C, D and HC are in
decimal format.
3) Servo Digital Input and Servo Digital Output are only for Servo.
Pay close attention to the following important notes:
4) For Delta AC drive:
Communication address for HMI read/write address uses hexadecimal format. For detailed information
about communication address of Delta AC drive, please refer to Delta AC drive “User Manual”.
Example 1: Parameter 9-01 of Delta VFD-S drive Transmission Speed needs to be set to INVERTER901
in HMI. (Decimal 9 is converted to 09 in hexadecimal and 01 is converted to 01 in hexadecimal.
Therefore, setting INVERTER901 to HMI will discard the first 0)
Decimal value
Hexadecimal value
01 (Hexadecimal value)
09 (Hexadecimal value)
The communication address of parameter 9-01 is 0901H.
Example 2: if setting of parameter 8-17 (Lower Bound of DC Braking Start-up Frequency) of Delta VFD-
S drive is desired, user needs to set INVERTER811 in HMI. (8 is converted to 08 in hexadecimal and 17
is converted to 11 in hexadecimal. Therefore, setting the INVERTER811 to HMI will discard the first 0)
Decimal value
Hexadecimal value
11 (Hexadecimal value)
08 (Hexadecimal value)
The communication address of parameter 8-17 is 0811H.
5) For Delta Servo drive:
y
HMI Read/Write address setting needs to input the communication address listed in SERVO “User
Manual”.
y
Servo Digital Input and Servo Digital Output are only for Servo.
6) For Delta Temperature Controller (DTA series):
HMI can be set up to connect to several Delta A series temperature controllers on standard Modbus
networks by using RTU transmission mode. However, the communication delay time may need to
increase. Therefore, 5ms or longer is highly recommended.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-10
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
Delta Servo
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
CN3 cable connector (RS-232)
Controller
CN3 cable connector
(RS-232)
RXD (2)
(2) TX
TXD (3)
GND (5)
(4) RX
(1) GND
1
2
3
5
4 6
Top View
RS-422
DOP Series
9 pin D-SUB male (RS-422)
Controller
CN3 cable connector (RS-422)
Controller
CN3 cable connector
(RS-422)
RXD+ (2)
(5) TX+
RXD- (1)
TXD+ (3)
(6) TX-
(3) RX+
TXD- (4)
(4) RX-
1
2
3
5
4 6
Top View
RS-485
DOP Series
9 pin D-SUB male (RS-485)
Controller
CN3 cable connector (RS-485)
Controller
CN3 cable connector
(RS-485)
RXD+ (2)
(3) 485+
TXD+ (3)
RXD- (1)
(5) 485+
(4) 485-
TXD- (4)
(6) 485-
1
2
3
5
4 6
Top View
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 11
Delta AC drive
RS-485
DOP Series
9 pin D-SUB male (RS-485)
Controller
RJ-11 cable connector (RS-485)
Controller
RJ-11 cable connector (RS-485)
RXD+ (2)
(4) SG+
TXD+ (3)
RXD- (1)
TXD- (4)
(3) SG-
GND (5)
(2) GND
Top View
DO NOT use Pin 1, 5 and 6 while
using RS-485 communication.
6
1
2: GND
3: SG-
4: SG+
NOTE
1) When connecting to a Delta VFD-M series AC drive, please connect Pin 5 (GND) of the Delta HMI and
Pin 2 (GND) of the Delta VFD-M AC drive.
Temperature Controller
RS-485
DOP Series
9 pin D-SUB male (RS-485)
Controller
RS-485 cable connector
RXD+ (2)
D+
TXD+ (3)
RXD- (1)
TXD- (4)
D-
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-12
Revision January 2008 Doc Name: 2007PDD23000007
Delta DVP PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, Even, 1.
Controller station number: 1.
Control area/status area: D0 / D10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
X_Data
Xn
n: 0 ~ 360(octal)
N/A
Y_Data
Yn
n: 0 ~ 360(octal)
N/A
M_Data
Mn
n: 0 ~ 1520, 1536 ~ 4080
N/A
S_Data
Sn
n: 0 ~ 1008
N/A
T_Register
Tn
n: 0 ~ 255
N/A
C_Register
Cn
n: 0 ~ 199
N/A
D_Register
Dn
n: 0 ~ 4095, 4096 ~ 9999
N/A
HC_Register
Cn
n: 200 ~ 255
N/A
NOTE
1) (W) is “Word”.
2) (DW) is “Double Word”.
3) X_Data / Y_Data / M_Data / S_Data: Address must be 0 or the multiple of 16.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
X_Data
Xn
N/A
n: 0 ~ 377(octal)
Y_Data
Yn
N/A
n: 0 ~ 377(octal)
M_Data
Mn
N/A
n: 0 ~ 1520, 1536 ~ 4080
S_Data
Sn
N/A
n: 0 ~ 1023
T_Coil
Tn
N/A
n: 0 ~ 255
C_Coil
Cn
N/A
n: 0 ~ 255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 13
C. Connections (Connector Pinouts)
RS-232 Connection
DOP Series
9 pin D-SUB male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
RXD (2)
(5) TXD
TXD (3)
GND (5)
(4) RXD
(8) GND
Top View
RS-485 Connection
DOP Series
9 pin D-SUB male (RS-485)
Controller
RS-485 cable connector
RXD+ (2)
D+
TXD+ (3)
RXD- (1)
TXD- (4)
D-
1
4
5
8
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-14
Revision January 2008 Doc Name: 2007PDD23000007
AllenBradley MicroLogix PLC
Back to Table
A. HMI factory setting
Baud rate: 19200, 8, None, 1.
PLC station number: 1.
Control area/status area: B3:0/B3:10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Bit No.
Register Type
Format
Word No.
Low Byte
High Byte
File No.
Output File
O:n
n: 0 ~ 3
N/A
0
Input File
I:n
n: 0 ~ 3
N/A
1
Status File
S2:n
n: 0 ~ 65
N/A
2
Bit File
B3:n
n: 0 ~ 255
N/A
3
Timer Flag
T4:n
n: 0 ~ 255
N/A
4
Timer Preset Value
T4:n.PRE
n: 0 ~ 255
N/A
4
Timer Accumulator Value
T4:n.ACC
n: 0 ~ 255
N/A
4
Counter Flag
C5:n
n: 0 ~ 255
N/A
5
Counter Preset Value
C5:n.PRE
n: 0 ~ 255
N/A
5
Counter Accumulator Value
C5:n.ACC
n: 0 ~ 255
N/A
5
Control File
R6:n
n: 0 ~ 255
N/A
6
Control Size of Bit Array
R6:n.LEN
n: 0 ~ 255
N/A
6
Control Reserved File
R6:n.POS
n: 0 ~ 255
N/A
6
Integer File
N7:n
n: 0 ~ 255
N/A
7
¾ Bit No : Low byte is not used, so the value is 0. High byte stores file number.
¾ Data Size : Word.
¾ T4, C5 and R6 only read 1 Word once.
¾ If reading multiple Words once, the communication speed of PLC will be slow.
NOTE
1) After last communication data has been memorized by PLC (PLC will send 0x10 0x05 consecutively),
communication may fail. At this time, power off and power up HMI or power off and power up PLC once.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 15
Contacts
Read/Write Range
Bit No.
Low Byte
High Byte
Contact Type
Format
Word No.
Bits
File No.
Output
O:n/b
n: 0 ~ 3
b: 0 ~ 15
0
Input
I:n/b
n: 0 ~ 3
b: 0 ~ 15
1
Status
S2:n/b
n: 0 ~ 65
b: 0 ~ 15
2
Bit
B3:n/b
n: 0 ~ 255
b: 0 ~ 15
3
Timer
T4:n/b
n: 0 ~ 255
b: 0 ~ 15
T4:n/EN
n: 0 ~ 255
15
T4:n/TT
n: 0 ~ 255
14
T4:n/DN
n: 0 ~ 255
13
4
Timer Preset Value
T4:n.PRE/b
n: 0 ~ 255
b: 0 ~ 15
4
Timer Accumulator Value
T4:n.ACC/b
n: 0 ~ 255
b: 0 ~ 15
4
Counter flag
C5:n/b
n: 0 ~ 255
b: 0 ~ 15
C5:n/CU
n: 0 ~ 255
15
C5:n/CD
n: 0 ~ 255
14
C5:n/DN
n: 0 ~ 255
13
C5:n/OV
n: 0 ~ 255
12
C5:n/UN
n: 0 ~ 255
11
C5:n/UA
n: 0 ~ 255
10
5
Counter Preset Value
C5:n.PRE/b
n: 0 ~ 255
b: 0 ~ 15
5
Counter Accumulator Value
C5:n.ACC/b
n: 0 ~ 255
b: 0 ~ 15
5
Control
R6:n/b
n: 0 ~ 255
b: 0 ~ 15
R6:n/EN
n: 0 ~ 255
15
R6:n/DN
n: 0 ~ 255
13
R6:n/ER
n: 0 ~ 255
11
R6:n/UL
n: 0 ~ 255
10
R6:n/IN
n: 0 ~ 255
9
R6:n/FD
n: 0 ~ 255
8
6
Control Size of Bit Array
R6:n.LEN/b
n: 0 ~ 255
b: 0 ~ 15
6
Control Reserved
R6:n.POS/b
n: 0 ~ 255
b: 0 ~ 15
6
Integer
N7:n/b
n: 0 ~ 255
b: 0 ~ 15
7
¾ Bit No : Low byte stores Bit address. High byte stores file number.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-16
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232 Connection
DOP Series
9 pin D-SUB male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
Controller
8 pin Mini DIN male
(RS-232)
RXD (2)
(7) TXD
TXD (3)
GND (5)
(4) RXD
(2) GND
(3) RTS
(6) CTS
Top View
1
4 3
7
2
6
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 17
AllenBradley SLC5 PLC
Back to Table
A. HMI factory setting
Baud rate: 19200, 8, None, 1.
PLC station number: 1.
Control area/status area: B3:0/B3:10.
NOTE
1) Error Check uses CRC (Cyclical Redundancy Check).
B. Definition of controller Read/Write address
Registers
Read/Write Range
Word No.
Bit No.
Low Byte
High Byte
Register Type
Format
Element No.
Slot or File No.
Output File
O:n
O:s.n
n: 0 ~ 30
N/A
Slot No. s = 0
s: 0 ~ 255
File No. = 0
Input File
I:n
I:s.n
n: 0 ~ 30
N/A
Slot No. s = 0
s: 0 ~ 255
File No. = 1
Status File
S2:n
n: 0 ~ 255
N/A
File No. = 2
Bit File
Bf:n
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 3.
Timer Flag
Tf:n
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Timer Preset Value
Tf:n.PRE
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Timer Accumulator Value
Tf:n.ACC
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Counter Flag
Cf:n
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Counter Preset Value
Cf:n.PRE
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-18
Revision January 2008 Doc Name: 2007PDD23000007
Read/Write Range
Word No.
Bit No.
Low Byte
High Byte
Register Type
Format
Element No.
Slot or File No.
Counter Accumulator Value
Cf:n.ACC
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Control File
Rf:n
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Control Size of Bit Array
Rf:n.LEN
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Control Reserved File
Rf:n.POS
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Integer File
Nf:n
n: 0 ~ 255
N/A
f: 10 ~ 255
If f is ignored, file no. will be
default setting 7.
¾ Bit No : Low byte is not used, so the value is 0. High byte stores file number.
Contacts
Read/Write Range
Word No.
Bit No.
Low Byte
High Byte
Contact Type
Format
Element No.
Bits
Slot or File No.
Output
O:n/b
O:s.n/b
n: 0 ~ 30
b: 0 ~ 15
Slot No. s = 0
s: 0 ~ 255
File No. = 0
Input
I:n/b
I:s.n/b
n: 0 ~ 30
b: 0 ~ 15
Slot No.
s = 0
s: 0 ~ 255
File No. = 1
Status
S2:n/b
n: 0 ~ 31
b: 0 ~ 15
2
Bit
Bf:n/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 3.
Timer
Tf:n/b
n: 0 ~ 255
b: 0 ~ 15
Tf:n/EN
n: 0 ~ 255
15
Tf:n/TT
n: 0 ~ 255
14
Tf:n/DN
n: 0 ~ 255
13
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Timer Preset Value
Tf:n.PRE/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 19
Read/Write Range
Word No.
Bit No.
Low Byte
High Byte
Contact Type
Format
Element No.
Bits
Slot or File No.
Timer Accumulator Value
Tf:n.ACC/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 4.
Counter Flag
Cf:n/b
n: 0 ~ 255
b: 0 ~ 15
Cf:n/CU
n: 0 ~ 255
15
Cf:n/CD
n: 0 ~ 255
14
Cf:n/DN
n: 0 ~ 255
13
Cf:n/OV
n: 0 ~ 255
12
Cf:n/UN
n: 0 ~ 255
11
Cf:n/UA
n: 0 ~ 255
10
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Counter Preset Value
Cf:n.PRE/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Counter Accumulator Value
Cf:n.ACC/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 5.
Control
Rf:n/b
n: 0 ~ 255
b: 0 ~ 15
Rf:n/EN
n: 0 ~ 255
15
Rf:n/DN
n: 0 ~ 255
13
Rf:n/ER
n: 0 ~ 255
11
Rf:n/UL
n: 0 ~ 255
10
Rf:n/IN
n: 0 ~ 255
9
Rf:n/FD
n: 0 ~ 255
8
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Control Size of Bit Array
Rf:n.LEN/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Control Reserved
Rf:n.POS/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 6.
Integer
Nf:n/b
n: 0 ~ 255
b: 0 ~ 15
f: 10 ~ 255
If f is ignored, file no. will be
default setting 7.
¾ Bit No : Low byte stores Bit address. High byte stores file number.
NOTE
1) Device O and I need to assign Slot No. (s). If not assign Slot No., it will use default setting 0.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-20
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB female (RS-232)
Controller
9 pin D-SUB female
(RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
(7) RTS
(8) CTS
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 21
Cimon PLC (Loader Protocol)
Back to Table
A. HMI factory setting
Baud rate: 38400, 8, None, 1, RS-232.
PLC station number: 1.
Control area/status area: D00000 / D00010.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Input
Xn
n: 000-512
N/A
Word
Output
Yn
n: 000-512
N/A
Word
General Purpose Relay
Mn
n: 000-999
N/A
Word
General Purpose Relay
Ln
n: 000-999
N/A
Word
Latch Relay
Kn
n: 000-999
N/A
Word
Flags
Fn
n: 000-127
N/A
Word
Timer (Set)
TSn
n: 0000-4095
N/A
Word
Timer (Current)
TCn
n: 0000-4095
N/A
Word
Counter (Set)
CSn
n: 0000-4095
N/A
Word
Counter (Current)
CCn
n: 0000-4095
N/A
Word
General Purpose Word Data
Dn
n:00000-31999
N/A
Word
Step Controller
Sn
n: 0-99
N/A
Byte
Contacts
Read/Write Range
Contact Type
Format
Word No.
Bit No.
Input
Xnb
n: 000-512
b: 0-F
Output
Ynb
n: 000-512
b: 0-F
General Purpose Relay
Mnb
n: 000-999
b: 0-F
General Purpose Relay
Lnb
n: 000-999
b: 0-F
Latch Relay
Knb
n: 000-999
b: 0-F
Flags
Fnb
n: 000-127
b: 0-F
Timer Status
Tb
N/A
b: 0-4095
Counter Status
Cb
N/A
b: 0-4095
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-22
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP series
9 pin D-SUB male (RS-232)
Controller
6 pin RJ11
Controller
9 pin D-SUB female
(RS-232)
RXD (2)
2
TXD (3)
GND (5)
3
5
Top View
NOTE
1) Device S
The unit of PLC internal memory is byte and Device S is read by the unit of byte. Therefore, we
recommend the user do not use two consecutive devices S as the read addresses or the interference will
occur. For example, when choosing two numeric input device, please use S24 and S26, do not use S24
and S25.
1 ~ 6
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 23
Copley Servo (Stepnet Protocol)
Back to Table
A. HMI factory setting
Baud rate: 9600, 8, None, 1.
PLC station number: 0.
Control area/status area: None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
RAM memory
Rn
n: 00-FF (Hex)
N/A
DWord
Flash memory
Fn
n: 00-FF (Hex)
N/A
DWord
Internal Register
IRn
n: 0-31
N/A
Word
Contacts
Read/Write Range
Contact Type
Format
Word No.
Bit No.
BIT_DEVICE_RB
RBn.b
n: 00-FF (Hex)
b: 0-31
BIT_DEVICE_FB
FBn.b
n: 00-FF (Hex)
b: 0-31
BIT_DEVICE_T0
T0n
N/A
n: 0
BIT_DEVICE_T1
T1n
N/A
n: 0
BIT_DEVICE_T2
T2n
N/A
n: 0
BIT_DEVICE_RST
RSTn
N/A
n: 0
BIT_DEVICE_CPR
CPRn
n: 00-FF (Hex)
N/A
BIT_DEVICE_CPF
CPFn
n: 00-FF (Hex)
N/A
NOTE
1) RB and FB are the bit access of Ram/Flash memory. Therefore, RB0x21.14 indicates bit 14 of Ram
memory 0x21.
2) T0, T1 and T2 is virtual device for simulating Trajectory Generator Command. The number of 0, 1 and 2
indicates the subcommand of that command, so only bit 0 is acceptable.
3) RST is for simulating Reset Command, so only bit 0 is acceptable.
4) CPR and CPF are for simulating Copy Command of Ram and Flash individually. The address (n) after
CPR and CPF is just the copy address for Ram/Flash memory. For example, CPRCA indicates that the
content of Ram memory 0xCA will be copied into Flash memory 0xCA and CPFA6 indicates that the
content of Flash memory 0xA6 will be copied into Ram memory 0xA6.
5) T0, T1, T2, RST, CPR, CPF are all write-only and they can not be used on Reset button.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-24
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB female (RS-232)
RXD (2)
RS-232 TxD
TXD (3)
GND (5)
RS-232 RxD
Signal Ground
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 25
Danfoss VLT 2800 (FC Protocol)
Back to Table
A. HMI factory setting
Baud rate: 9600, 8, Even, 1, RS-485.
PLC station number: 1.
Control area/status area: None / None.
NOTE
1) Delta HMI can be connected to for VLT-2800, 5000, 6000, 7000 controllers.
2) Each data length format of Danfoss AC drive parameter is not fixed, therefore, “Multiple Duplicate”
function is not provided.
3) Max. supported alarm number is 16. If the alarm number is over 16, a fault will occur.
4) Does not support “optimum read/write” characteristic.
5) If the selected element is a string, the minimum data length should be more than 2.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Bit No.
Low Byte
High Byte
Register Type
Format
Word No.
Index No.
Parameter
Pn:I
n: 0 ~ 999
0
I: 0 ~ 31
Control Word
CTRWD
0
N/A
N/A
Status Word
STAWD
0
N/A
N/A
¾ Index No : If the index No. is not used, its default setting will be 0. The default setting of index No. for
parameter P606 ~ P617 is 1.
¾ Please notice that it is necessary to input the index No. when using some parameters of Danfoss
controllers. At this time, please pay close attention on the setting range of index number. If the setting
range is not started from 0, the parameter read & write failure will occur. For example, the index No.
setting range of the parameter P615 is from 1 to 20, if the users do not input the index No., the system
will assume the index number is 0 (default setting) and the a fault will occur when the users read or write
the parameter.
¾ CTRWD: Write-only. (Can not be used on the devices which can display the value or input value. It is
recommended to be used on the setting value/setting constant (button), or marco function.)
¾ STAWD: Read-only.
¾ Control & Status Word: Please refer to the explanation on the next page.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-26
Revision January 2008 Doc Name: 2007PDD23000007
Contacts
Read/Write Range
Word No.
Bit No.
Low Byte
High Byte
Contact Type
Format
Element No.
Bits
Index No.
Parameter
Pn:I.b
n: 0 ~ 999
b: 0 ~ 31
I: 0 ~ 31
¾ Bit No : Low byte stores Bit address. High byte stores index number.
C. Connections (Connector Pinouts)
RS-485
DOP Series
9 pin D-SUB male (RS-485)
Controller
RS-485 cable connector
RXD+ (2)
68 TXD/RXD+
TXD+ (3)
RXD- (1)
TXD- (4)
Shell
Shell
69 TXD/RXD-
Explanation of Control Word & Status Word
Control Word
Bit
Bit = 0
Bit = 1
15
No Function
Reversing
14
Choice of Setup 2 (msb)
13
Choice of Setup 1 (lsb)
12
No Function
Relay 04 activated
11
No Function
Relay 01 activated
10
Data Not Vaild
Vaild
9
Ramp 1
Ramp2
8
Jog 1 OFF
ON
7
No Function
Reset
6
Ramp Stop
Start
5
Hold
Ramp Enable
4
Quick-Stop
Ramp
3
Coasting
Enable
2
DC Brake
Ramp
1
Preset reference choice msb
0
Preset reference choice msb
¾ When Bit 10 = 1 (Data Valid), the Control Word is valid.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 27
Status Word
Bit
Bit = 0
Bit = 1
15
Timer OK
Above limit
14
Torque OK
Above limit
13
Voltage OK
Above limit
12
Temperature OK
Over-Temp, auto-start pending
11
Not Running
Running
10
Out of Range
Frequency OK
9
Local Control
Bus Control
8
Speed ≠ reference
Speed = reference
7
No Warning
Warning
6
Reserved
5
Reserved
4
Reserved
3
No Fault
Trip
2
Coasting
Enabled
1
VLT not ready
Ready
0
Control not ready
Ready
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-28
Revision January 2008 Doc Name: 2007PDD23000007
Emerson EC20 Series PLC
Back to Table
A. HMI factory setting
Baud rate: 19200, 8, Even, 1 (RS-232).
PLC station number: 0.
Control area/status area: D0 / D10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Data Word
Dn
n: 0-7999
N/A
Word
Special Data Word
SDn
n: 0-255
N/A
Word
Data Word
Zn
n: 0-15
N/A
Word
Timer
Tn
n: 0-255
N/A
Word
Counter
Cn
n: 0-199
N/A
Word
DoubleWord Counter
CDWn
n: 200-255
N/A
DWord
DoubleWord Data Word
DDWn
n: 0-7998
N/A
DWord
Contacts
Read/Write Range
Contact Type
Format
Word No.
Bit No.
External Output Relay
Yb
N/A
b: 0-377(Octal)
External Input Relay
Xb
N/A
b: 0-377(Octal)
Internal Relay
Mb
N/A
b: 0-1999
Special Internal Relay
SMb
N/A
b: 0-255
Status Relay
Sb
N/A
b: 0-991
Timer
Tb
N/A
b: 0-255
Counter
Cb
N/A
b: 0-255
NOTE
PLC Communication Settings:
1) Emerson EC20 series PLC has two communication ports, COM0 and COM1. They are provided for the
communication protocol for connecting to PC, Modbus communication protocol and user-defined
protocol. The default setting is COM0 to be enabled only, so the user needs to set the communication
mode as Modbus RTU via PC software before using it.
2) COM1 supports RS-232 and RS-485.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 29
3) Please note that not all of the addresses can be written when reading SM and SD device. We
recommend the user not to set all of the addresses as write address except when setting parameters.
C. Connections (Connector Pinouts)
RS-232
DOP series
9 pin D-SUB male (RS-232)
Controller
COM1
RXD (2)
TXD
TXD (3)
GND (5)
RXD
GND
RS-485
DOP series
9 pin D-SUB male (RS-232)
Controller
COM1
D- (1)
(3) RS485+
D- (4)
D+ (2)
(4) RS485-
D+ (3)
GND (5)
GND
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-30
Revision January 2008 Doc Name: 2007PDD23000007
Facon FB Series PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, Even, 1.
Controller Station number: 1.
Control area/status area: R0 / R10.
B. Definition of controller Read/Write address
Registers
Read/Write range
Register Type
Format
Word No.
Bit No.
Data length
Input Relay
WXn
n: 0 ~ 9992
N/A
Byte
Output Relay
WYn
n: 0 ~ 9992
N/A
Byte
Internal Relay
WMn
n: 0 ~ 9992
N/A
Byte
Step Relay
WSn
n: 0 ~ 9992
N/A
Byte
Data Register
Rn
n: 0 ~ 65534
N/A
Word
Data Register
Dn
n: 0 ~ 65534
N/A
Word
Timer Present Value
RTn
n: 0 ~ 9999
N/A
Word
Counter Present Value
RCn
n: 0 ~ 9999
N/A
Word
Data Register
DRCn
n: 200 ~ 255
N/A
Double Word
¾ Input Relay / Output Relay / Internal Relay / Special Relay: Address must be the multiple of 8.
Contacts
Read/Write range
Contact type
Format
Word No.
Bit No.
Input Relay
Xn
N/A
n: 0 ~ 9999
Output Relay
Yn
N/A
n: 0 ~ 9999
Internal Relay
Mn
N/A
n: 0 ~ 9999
Step Relay
Sn
N/A
n: 0 ~ 9999
Timer Flag
Tn
N/A
n: 0 ~ 9999
Counter Flag
Cn
N/A
n: 0 ~ 9999
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 31
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
15 pin male (RS-232)
Controller
15 pin male (RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(1) RXD
(6) SG
(3) RTS
(4) CTS
Top View
RS-232
Connecting to CB (Communication Board) or CM (Communication Module)
FBs Series Port 1
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(5) GND
(8) RTS
(7) CTS
RS-232
FBs Series Port 0
DOP Series
9 pin D-SUB male (RS-232)
Controller
4 pin Mini DIN male (RS-232)
Controller
4 pin Mini DIN male
(RS-232)
RXD (2)
(4) TXD
TXD (3)
GND (5)
(2) RXD
(1) GND
(3) +5V
Pin1
Pin1
1
2
3
4
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-32
Revision January 2008 Doc Name: 2007PDD23000007
Festo PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, None, 1.
Controller Station number: 0. (no PLC station number in protocol)
Control area/status area: R0 / R10.
NOTE
1) Connectable PLC: FEC-FC Model
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
WORD_DEVICE_IW
Iwn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_OW
Own
n: 0 ~ 255
N/A
Word
WORD_DEVICE_FW
FWn
n: 0 ~ 9999
N/A
Word
WORD_DEVICE_TW
TWn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_CW
CWn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_R
Rn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_TP
TPn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_CP
CPn
n: 0 ~ 255
N/A
Word
Contacts
Register Type
Format
Word No.
Bit No.
BIT_DEVICE_I
In.b
n: 0 ~ 255
b: 0 ~ 15
BIT_DEVICE_O
On.b
n: 0 ~ 255
b: 0 ~ 15
BIT_DEVICE_F
Fn.b
n: 0 ~ 9999
b: 0 ~ 15
BIT_DEVICE_T
Tn
N/A
n: 0 ~ 255
BIT_DEVICE_C
Cn
N/A
n: 0 ~ 255
BIT_DEVICE_TON
TONn
N/A
n: 0 ~ 255
BIT_DEVICE_TOFF
TOFFn
N/A
n: 0 ~ 255
¾ BIT_DEVICE_T / BIT_DEVICE_C / BIT_DEVICE_TON / BIT_DEVICE_TOFF: Only 1 Bit can be
transferred for each communication.
¾ Only 1 Bit or 1 Word can be transferred for each write command.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 33
C. Connections
NOTE
1) Communication port of PLC: COM port
2) It needs to use the dedicated cable for FESTO controllers Æ Cable for transferring TTL to RS-232 and it
is 6 pin RJ-12 connector at PLC side.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-34
Revision January 2008 Doc Name: 2007PDD23000007
GE Fanuc 90 Series SNP PLC
Back to Table
A. HMI factory settings
Baud rate: 19200, 8, ODD, 1.
Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: %R1 / %R10.
NOTE
1) Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication
is allowed.
2) If the PLC enabled “Check Password” function, the user needs to set the password by clicking Option >
Configuration > Communication. The user can find Controller Settings and set PLC password on
Communication Tab in the Configuration dialog box. Please enter a 4-digit password (If entering a
password that exceeds 4-digit number, only the first 4-digit number is valid).
B. Definition of controller Read/Write address
Registers
Read/Write range
Register Type
Format
Word No.
Bit No.
Data length
Discrete Inputs
%In
n: 1 ~ 12288
N/A
Word (the multiple of 16 + 1)
Discrete Outputs
%Qn
n: 1 ~ 12288
N/A
Word (the multiple of 16 + 1)
Discrete Temporaries
%Tn
n: 1 ~ 256
N/A
Word (the multiple of 16 + 1)
Discrete Internals
%Mn
n: 1 ~ 12288
N/A
Word (the multiple of 16 + 1)
%SA Discretes
%SAn
n: 1 ~ 128
N/A
Word (the multiple of 16 + 1)
%SB Discretes
%SBn
n: 1 ~ 128
N/A
Word (the multiple of 16 + 1)
%SC Discretes
%SCn
n: 1 ~ 128
N/A
Word (the multiple of 16 + 1)
%S Discretes
%S-n
n: 1 ~ 128
N/A
Word (the multiple of 16 + 1)
Genius Global Data
%Gn
n: 1 ~ 7680
N/A
Word (the multiple of 16 + 1)
Registers
%Rn
n: 1 ~ 16384
N/A
Word
Analog Inputs
%AIn
n: 1 ~ 8192
N/A
Word
Analog Outputs
%AQn
n: 1 ~ 8192
N/A
Word
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 35
Contacts
Read/Write range
Contact Type
Format
Word No.
Bit No.
Discrete Inputs
%In
N/A
n: 1 ~ 12288
Discrete Outputs
%Qn
N/A
n: 1 ~ 12288
Discrete Temporaries
%Tn
N/A
n: 1 ~ 256
Discrete Internals
%Mn
N/A
n: 1 ~ 12288
%SA Discretes
%SAn
N/A
n: 1 ~ 128
%SB Discretes
%SBn
N/A
n: 1 ~ 128
%SC Discretes
%SCn
N/A
n: 1 ~ 128
%S Discretes
%-Sn
N/A
n: 1 ~ 128
Genius Global Data
%Gn
N/A
n: 1 ~ 7680
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male
(RS-232)
Controller
RJ-45 cable connector
(RS-232)
Controller
RJ-45 cable connector
(RS-232)
RXD (2)
(5) TXD
TXD (3)
GND (5)
(6) RXD
(4) GND
Top View
8
1
RS-422
DOP Series
9 pin D-SUB male (RS-232)
Controller
15 pin male (RS-232)
Controller
15 pin male (RS-232)
RXD+ (2)
(13) SD(B')
TXD+ (3)
TXD- (4)
(11) RD(B)
(10 ) RD(A)
(6) RTS(A)
(15 ) CTS(A')
RXD- (1)
(12 ) SD(A')
(8) CTS(B)
(14 ) RTS(B')
(9) RD( *)
(NOT E 1 )
Top View
NOTE
1) (9) RD(*) should be connected to 10(RD)(A) in serial. But if connecting PLC model is Series 90-70 PLC
IC697CPU731 and IC697CPU771, (9) RD(*) needs to be connected to 11(RD)(B).
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-36
Revision January 2008 Doc Name: 2007PDD23000007
Hitachi EH Series PLC
Back to Table
A. HMI factory settings
Baud rate: 19200, 7, EVEN, 1.
Controller station number: 0.
Control area/status area: WR0 / WR10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
External Input WX
WXrusn
Word
External Output WY
WYrusn
s: 0-A
n: 0-7
r: 0-4
u: 0-4
N/A
Word
Internal Output WR
WRn
n: 0-C3FF
N/A
Word
Special Internal Output WR
WRn
n: F000-F1FF
N/A
Word
Shared Internal Output WM
WMn
n: 0-3FF
N/A
Word
CPU Link Area 1 WL
WLn
n: 0-3FF
N/A
Word
CPU Link Area 2 WL
WLn
n: 1000-13FF
N/A
Word
Timer/Counter TC
TCn
n: 0-511
N/A
Word
Contacts
Read/Write Range
Register Type
Format
Word No.
Bit No.
External Input X
Xrusb
External Output Y
Yrusb
s: 0-A
N/A
r: 0-4
u: 0-4
b: 0-95
Internal Output R
Rb
N/A
b: 0-7FF
Shared Internal Output M
Mnb
n: 0-3FF
b: 0-F
CPU Link Area 1 L
Lnb
n: 0-3FF
b: 0-F
CPU Link Area 2 L
Lnb
n: 1000-13FF
b: 0-F
On Delay Timer TD
TDb
N/A
b: 0-255
Single-shot Timer SS
SSb
N/A
b: 0-255
Up Counter CU
CUb
N/A
b: 0-511
Up-down Counter up input CTU
CTUb
N/A
b: 0-511
Up-down Counter down input CTD
CTDb
N/A
b: 0-511
Up-down Counter down output CT
CTb
N/A
b: 0-511
Progress Value Clear CL
CLb
N/A
b: 0-511
Rising Edge Detection DIF
DIFb
N/A
b: 0-511
Falling Edge Detection DFN
DFNb
N/A
b: 0-511
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 37
NOTE
1) Communication Settings:
y
In Hitachi EH series PLC, only port 1 can be used for communication through procedure 2. The
user can select procedure type via DIP switch and specific Special Internal Input (WR).
y
In Hitachi EH-150 series PLC, only EH-CPU***A/448/516/548 can use procedure 2.
y
It needs to set the external I/O (WX, WY, X, Y) of EH series PLC first or HMI cannot read and write
their addresses.
y
Hitachi EH series PLC and PC can be connected only by procedure 1 (@19200bps)
2) CPU Relevant Notice:
EH-150
y
DIP5 should be set to ON.
y
If DIP5 is set to ON, PLC will determine the proper procedure (1 or 2) by the value of WRf037.
When setting the address, the highest bit of write value must be 1 and then PLC can write the value
into other seven bits. The data will not lost even when the power of PLC is cut off. Therefore,
i)
Write the value 0x8000 into the address. After restart PLC, the address value will become
0x0000 and perform communication by procedure 1.
ii)
Write the value 0xC000 into the address. After restart PLC, the address value will become
0x4000 and perform communication by procedure 2.
y
Use DIP3 and DIP4 to set the communication speed of port 1.
i)
When DIP3 is ON and DIP4 is OFF, the communication speed is 19200bps.
y
Use DIP6, PHL to set the communication speed of port 2.
i)
When DIP6 is ON and PHL is OFF, the communication speed is 19200bps.
ii)
The EH-150 PLC is a “Base Unit” which has a built-in CPU module. This unit allows easy
connection of extension module, such as “External I/O”.
MicroEH
y
DIP5 is used to set communication speed.
i)
When SW1 is ON, the communication speed is 19200bps.
y
MicroEH PLC will determine the proper procedure (1 or 2) by the value of WRf01a. Different than
EH-150, when setting the address, the highest bit of write value does not need to be 1. But the data
will lost even the power of PLC is cut off. However, if set the value of R7f6 to 1, the data of WRf01a
will be saved into Flash memory.
i)
0x0000 for procedure 1.
ii)
0x8000 for procedure 2.
iii)
If the PLC uses procedure 2 and saves the data into Flash memory, it cannot connect to
the peripheral devices and programs (Ladder Editor) that only support procedure 1.
iv)
Standard External I/O built in MicroEH PLC are listed as below:
Digital Type
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-38
Revision January 2008 Doc Name: 2007PDD23000007
slot 0: X48
slot 1: Y32
slot 2: empty16
Analog Type
slot 3: X4W
slot 4: Y4W
3) Communication Protocol:
External I/O (X, Y, WX, WY)
y
Address rules:[r][u][s][n/b].
i)
Word no/Bit no [n/b]
ii)
Slot number [s]
iii)
Unit number [u]
iv)
Remote number [r]
Only support EH-150
v)
ex1: WX103 represents unit 1, word 3 of slot 0
vi)
ex2: X103 represents bit 3 of slot 1
vii)
ex3: X113 represents bit 13 of slot 1
viii)
ex4: Y2004 represents unit 2, bit 4 of slot 0
ix)
ex5: Y2104 represents unit 2, bit 4 of slot 1
y
External I/O (X, Y, WX, WY) cannot read and write several addresses one time so they do not
support “optimum read/write” characteristic.
Internal Output
y
Shared Internal Output (M, WM) read and write the same address. For example,
i)
M3ab and WM3a: the read and write address of M3ab is the bit b of WM3a.
y
CPU Link Area (L, WL) are the same as Shared Internal Output (M, WM). CPU Link Area (L, WL)
also read and write the same address.
i)
Only support EH-150.
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(5) SD1
TXD (3)
GND (5)
(6) RD1
(1) SG1
RTS (7)
(7) DR1
CT S (8)
(8) RS1
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 39
HUST CNC Controller
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 2.
Controller station number: 0.
Control area/status area: W0 / W10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Word Register
Wn
n: 0 ~ 13500
N/A
Word
Double Word Register Dn
n: 0 ~ 13500
N/A
Double Word
NOTE
1) The unit for Hust CNC controller is D Word and Wn is the low word of Dn.
Contacts
Read/Write range
Contact Type
Format
Word No.
Bit No.
BIT_DEVICE_B
Bm.n
m: 0 ~ 13500
n: 0 ~ 31
BIT_DEVICE_I
In
N/A
n: 0 ~ 255 (8 DW)
BIT_DEVICE_O
On
N/A
n: 0 ~ 255 (8 DW)
BIT_DEVICE_C
Cn
N/A
n: 0 ~ 255 (8 DW)
BIT_DEVICE_S
Sn
N/A
n: 0 ~ 255 (8 DW)
BIT_DEVICE_A
An
N/A
n: 0 ~ 1023 (32 DW)
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male
(RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(5) SG
(8) RTS
(7) CTS
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-40
Revision January 2008 Doc Name: 2007PDD23000007
Jetter Nano Series PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, EVEN, 1 (RS-232).
Controller station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: WR0 / WR10.
NOTE
1) Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication
is allowed.
2) Only 1 Bit or 1 Word can be transferred for each communication.
3) In general, each register occupies max. 24 Bits. However, some registers occupies 8 Bits only.
4) Because the initial time of this controller is longer, it is recommended to set HMI startup delay time
(Recommended time is 10 seconds).
5) When the register R is used for Double Word device, please set its format as signed format. (The default
format in Screen Editor is signed format)
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data
Length
16 Bits Register
WRn
n:
0 ~ 32767
N/A
16 Bits
32 Bits Register
Rn
n:
0 ~ 32767
N/A
24 Bits
Only the first 16 bits are used for WRn registers.
Only the first 24 bits are used for Rn registers, the highest 8 bits (Bit 24 ~ 31) are set to 0 by default setting.
(24-bit Integer : If in decimal format, the range is -8388608 ~ +8388607. If in hexadecimal format, the range
is 0x000000 ~ 0xFFFFFF.)
NOTE
1) The difference between WRn and Rn:
y
When using devices that the data length is in Word, only Bit 0 ~ 15 are valid for both of WRn and
Rn registers.
y
When using devices that the data length is in Double Word,
if the read/write address format is set to WRn, the Bit 0 ~ 15 of WRn register is the low word of a
read/write value, the Bit 0 ~ 15 of WRn+1 register is the high word of a read/write value.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 41
if the read/write address format is set to Rn, only Bit 0 ~ 23 are valid for Rn registers.
(Notice: As the Jetter controller is a 24-bit format controller, the valid setting range is 24 Bits.
If exceeds this range, HMI will stop read/write operation and show “…..Value is Incorrect”
on the screen. So, please do not set any bit on Bit24 ~ Bit31 (Bit24 ~ Bit31 cannot be written).
y
When using devices that the data length is in m Words,
if the read/write address format is set to WRn, the Bit 0 ~ 15 of WRn register is the lowest word of a
read/write value and the Bit 0 ~ 15 of WRn+m-1 register is the highest word of a read/write value.
if the read/write address format is set to Rn, the Bit 0 ~ 23 of Rn register is the lowest word of a
read/write value and the Bit 0 ~ 23 of Rn+1 register is the highest word of a read/write value.
Each register is regards as a “Double Word”. The value of Bit24 ~ Bit31 is 0.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input Relay
Inbb
n: 1 ~ 32
bb:
01 ~ 08
Output Relay
Onbb
n: 1 ~ 32
bb:
01 ~ 08
Flag Relay
Fn
N/A
n:
0 ~ 32767
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male
(RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(7) GND
Top View
¾ The pin definition of the cable of Jetter controller is different than the general RS-232 cable. Please pay
close attention.
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-42
Revision January 2008 Doc Name: 2007PDD23000007
Jetter JC Series PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, EVEN, 1 (RS-232).
Controller station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: WR0 / WR10.
NOTE
1) Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication
is allowed.
2) Only 1 Bit or 1 Word / 2 Words can be transferred for each read and write command.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data
Length
16 Bits Register
WRn
n:
0 ~ 32767
N/A
16 Bits
32 Bits Register
Rn
n:
0 ~ 32767
N/A
24 Bits
The characteristics of WRn and Rn of JC series are the same as the Nano series. Please refer to the section
that introduces Jetter Nano Series PLC.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input Relay
Inbb
n: 1 ~ 32
bb:
01 ~ 16
Output Relay
Onbb
n: 1 ~ 32
bb:
01 ~ 16
Flag Relay
Fn
N/A
n:
0 ~ 32767
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 43
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
RXD (2)
(8) TXD
TXD (3)
GND (5)
(4) RXD
(2) GND
Top View
2
4
8
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-44
Revision January 2008 Doc Name: 2007PDD23000007
Keyence KV/KZ Series
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, EVEN, 1 (RS-232).
Controller station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: DM-0 / DM-10.
NOTE
1) Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication
is allowed.
2) Only 1 Bit or 1 Word can be transferred for each communication. (Communication speed is slow.)
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Timer
T-nnn
nnn:
0 ~ 199
N/A
Word
Counter
C-nnn
nnn:
0 ~ 199
N/A
Word
High-speed Counter
CTH-n
n:
0 ~ 1
N/A
Word
High-speed Counter
Comparator
CTC-n
n:
0 ~ 3
N/A
Word
Data Memory
DM-nnnn
nnnn:
0 ~ 1999
N/A
Word
Temporary Data Memory
TM-nn
nn:
0 ~ 31
N/A
Word
Timer Preset Value
PT-nnn
nnn:
0 ~ 199
N/A
Word
Counter Preset Value
PC-nnn
nnn:
0 ~ 199
N/A
Word
CTC Preset Value
PCTC-n
n:
0 ~ 3
N/A
Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Relay
R-nnnbb
nnn: 0 ~ 69
bb:
00 ~ 15
Timer
T-nnn
N/A
nnn:
0 ~ 199
Counter
C-nnn
N/A
nnn:
0 ~ 199
High-speed counter
comparator
CTC-n
N/A
n:
0 ~ 3
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 45
NOTE
When using the protocol format of KV series and connecting to KZ-80T PLC, some errors occur. Please refer
to the following description:
1) Readable Timer address is not continuous. For example, T-0 ~ T-9 can be read, T10 cannot be read,
T11 ~ T20 can be read, T21 ~ T50 cannot be read, …etc.
2) Counter cannot be read. For example,
Registers: C- (Counter), CTH- (High-speed counter), CTC- (High-speed counter comparator),
PC- (Counter preset value), PCTC- (CTC preset value) they all cannot be read.
Contacts: C- (Counter), CTC- (High-speed counter comparator) they all cannot be read also.
C. Connections (Connector Pinouts)
RS-232
KV Series
DOP
9 pin D-SUB male (RS-232)
Controller
RJ-11 cable connector (RS-232)
Controller
RJ-11 cable connector (RS-232)
RXD (2)
(3) SD
TXD (3)
GND (5)
(5) RD
(4) SG
Top View
6 - 1
PLC side (Comm. Port)
KZ Series
DOP
9 pin D-SUB male (RS-232)
Controller
RJ-11 cable connector (RS-232)
Controller
RJ-11 cable connector (RS-232)
RXD (2)
(5) SD
TXD (3)
GND (5)
(3) RD
(4) SG
Top View
6 - 1
PLC side (Comm. Port)
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-46
Revision January 2008 Doc Name: 2007PDD23000007
NOTE
1) Communication Cable: The pins of SD and RD of KZ-80T and KV Series are reverse.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 47
Koyo SU/DL Series
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, ODD, 1 (RS-232).
Controller station number: 1.
Control area/status area: V1400 / V1410.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data
Length
Timer Accumulated
Vn
n:
0 ~ 177 (octal)
N/A
Word
Counter Accumulated
Vn
n:
1000 ~ 1177 (octal)
N/A
Word
V Memory
Vn
n:
1400 ~ 7777 (octal)
N/A
Word
Linker Relays
Vn
n:
40000 ~ 40037 (octal)
N/A
Word
Input Status
Vn
n:
40400 ~ 40423 (octal)
N/A
Word
Output Status
Vn
n:
40500 ~ 40523 (octal)
N/A
Word
Control Relays
Vn
n:
40600 ~ 40635 (octal)
N/A
Word
Stage
Vn
n:
41000 ~ 41027 (octal)
N/A
Word
Timer Status
Vn
n:
41100 ~ 41107 (octal)
N/A
Word
Counter Status
Vn
n:
41140 ~ 41147 (octal)
N/A
Word
Spec. Relay 1
Vn
n:
41200 ~ 41205 (octal)
N/A
Word
Spec. Relay 2
Vn
n:
41216 ~ 41230 (octal)
N/A
Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Linker Relays
GXn
N/A
n:
0 ~ 777 (octal)
Input Status
Xn
N/A
n:
0 ~ 477 (octal)
Output Status
Yn
N/A
n:
0 ~ 477 (octal)
Control Relays
Cn
N/A
n:
0 ~ 737 (octal)
Stage
Sn
N/A
n:
0 ~ 577 (octal)
Timer Status
Tn
N/A
n:
0 ~ 177 (octal)
Counter Status
CTn
N/A
n:
0 ~ 177 (octal)
Spec. Relay 1
SPn
N/A
n:
0 ~ 137 (octal)
Spec. Relay 2
SPn
N/A
n:
320 ~ 617 (octal)
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-48
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
RJ-11 cable connector (RS-232)
Controller
RJ-11 cable connector
(RS-232)
RXD(2)
TXD(3)
GND(5)
(4)TXD
(3)RXD
(1)GND
(6)GND
Top View
1 - 6
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 49
Koyo K-Sequence
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, ODD, 1 (RS-232).
Controller station number: 1.
Control area/status area: R1400 / R1420.
NOTE
1) If read / write address exceeds the valid range, HMI will stop read/write operation and show “….Error
6….. Command Can Not be Executed….” on the screen.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data
Length
Input Status
Xnnnn
nnnn:
0 ~ 1760 (octal)
N/A
Word
Output Status
Ynnnn
nnnn:
0 ~ 1760 (octal)
N/A
Word
Link Relays
GXnnnn
nnnn:
0 ~ 3760 (octal)
N/A
Word
Relays
GQnnnn
nnnn:
0 ~ 3760 (octal)
N/A
Word
Relays
Mnnnn
nnnn:
0 ~ 3760 (octal)
N/A
Word
Stage
Snnnn
nnnn:
0 ~ 1760 (octal)
N/A
Word
Timer Status
Tnnn
nnn:
0 ~ 360 (octal)
N/A
Word
Control Relays
Cnnn
nnn:
0 ~ 360 (octal)
N/A
Word
Special Relay 1
SPnnn
nnn:
0 ~ 760 (octal)
N/A
Word
Register
Rnnnnn
nnnnn:
0 ~ 41237 (octal)
N/A
Word
Register
Pnnnnn
nnnnn:
0 ~ 37777 (octal)
N/A
Word
¾ nnnn: Is in octal format and must be the multiple of 16 except for R and P.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input Status
Xnnnn
N/A
nnnn:
0 ~ 1777 (octal)
Output Status
Ynnnn
N/A
nnnn:
0 ~ 1777 (octal)
Linker Relays
GXnnnn
N/A
nnnn:
0 ~ 3777 (octal)
Relays
GQnnnn
N/A
nnnn:
0 ~ 3777 (octal)
Control Relays
Mnnnn
N/A
nnnn:
0 ~ 3777 (octal)
Stage
Snnnn
N/A
nnnn:
0 ~ 1777 (octal)
Timer Status
Tnnn
N/A
nnn:
0 ~ 377 (octal)
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-50
Revision January 2008 Doc Name: 2007PDD23000007
Read/Write Range
Contact type
Format
Word No.
Bit No.
Counter Status
Cnnn
N/A
nnn:
0 ~ 377 (octal)
Spec. Relay 1
SPnnn
N/A
nnn:
0 ~ 777 (octal)
C. Connections (Connector Pinouts)
RS-232
Port 0 Communication Cable
DOP
9 pin D-SUB male (RS-232)
Controller
RJ-11 cable connector (RS-232)
Controller
RJ-11 cable connector
(RS-232)
RXD(2)
TXD(3)
GND(5)
(4)TXD
(3)RXD
(1)GND
(6)GND (Note 1)
Top View
1 - 6
¾ If pin 6 is not grounded, a communication error may occur when connecting to a CKD SM 24R controller.
Ensure that pin 6 is well grounded. This will not cause any problems when connecting to SN32DRA
controller.
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
Top View
RS-485
Port 1 Communication Cable
DOP
9 pin D-SUB male (RS-485)
DOP
9 pin D-SUB male (RS-485)
D- (1)
D-
D+ (2)
D+ (3)
D+
D- (4)
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 51
The corresponding registers of CCM2 and K-Sequence
Address Corresponding Relationship:
CCM2
K sequence
SN32DRA
V
R
R
X
X
I
Y
Y
Q
C
M
M
S
S
S
T
T
T
CT
C
C
SP
SP
SP
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-52
Revision January 2008 Doc Name: 2007PDD23000007
Lenze LECOM-A/B Protocol
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1 (Baudrate: 1200/2400/4800/9600/19200).
Controller station number: 1 (1~99).
Control area/status area: None / None.
NOTE
1) Please pay close attention to each pin definition of cable connectors.
2) Ensure not to use the general RS-232 5-pin cable. This is because if pin 2, 3, 5, 7, 8 are all connected to
the drive, the drive can not recognize the communication signal and can not identify what kind of
communication it is.
3) For more detailed information of pin definition of cable connectors, please refer to the C. Connections
(Connector Pinouts) of Lenze LECOM-A/B Protocol controller.
4) Ensure the HMI communication data format (The communication data written into the drive) is correct.
The Word “m” in the following table is used to specify the HMI communication data format.
5) Ensure the HMI display data format (Property table/Setting value...etc.) is correct.
6) When using broadcast function, please check if device is available. This is because the broadcast
function can be activated only when the user chooses “write only” device for broadcast station number
(only choose setting value/setting constant (button) and then the broadcast function can be used). If
choosing other devices, the system will ask you to read back the drive setting value, so please ensure to
choose the correct device. If choosing the incorrect devices, a “Controller Station Number Error…” fault
message will display on HMI screen.
7) Support 82XX frequency inverters and 93XX servo inverters.
B. Definition of controller Read/Write address
Registers (n, m, y are in decimal)
Read/Write Range
Word No.
Bit No.
LowByte
HighByte
Register Type
Format
subcode
Data Length
CWn
n: 1 ~ 10000
N/A
N/A
Word
Parameter without subcode
CWn.m
n: 1 ~ 10000
m: 0 ~ 23
N/A
Word
Parameter with subcode
CWn/y
n: 1 ~ 10000
N/A
y:1 ~ 255
Word
CWn/y.m
n: 1 ~ 10000
m: 0 ~ 23
y:1 ~ 255
Word
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 53
Read/Write Range
Word No.
Bit No.
LowByte
HighByte
Register Type
Format
subcode
Data Length
CDn
n: 1 ~ 10000
N/A
N/A
DoubleWord
Parameter without subcode
CDn.m
n: 1 ~ 10000
m: 0 ~ 23
N/A
DoubleWord
Parameter with subcode
CDn/y
n: 1 ~ 10000
N/A
y:1 ~ 255
DoubleWord
CDn/y.m
n: 1 ~ 10000
m: 0 ~ 23
y:1 ~ 255
DoubleWord
NOTE
1) m : HMI communication data format
2) The value of m represents the different communication data format:
y
If m value is undefined: ASCII hexadecimal format (VH). (4 or 8 numbers.)
y
m >= 23
: ASCII hexadecimal format (VH). (4 or 8 numbers.)
y
m = 0 ~10
: unsigned, ASCII decimal format (VD).
m represents decimal place, For example:
m=0 Æ no decimal place
m=1 Æ one decimal place (tenth)
m=2 Æ two decimal place (hundredth)
y
m = 11 ~20
: signed, ASCII decimal format (VD).
m represents decimal place, For example:
m=11 Æ one decimal place (tenth)
m=12 Æ two decimal place (hundredth)
y
m = 21
: signed, ASCII decimal format (VD).
without decimal place
y
m = 22
: ASCII hexadecimal format (VH). 2 numbers.
when using this format, the write value will be limited within the range of 0~0xFF
(low byte).
For example: when entering 0x1234 during communication, the actual write value
is 0x34, not 0x1234.
Contacts (n, b, y are in decimal)
Read/Write Range
Word No.
Bit No.
LowByte
HighByte
Register Type
Format
subcode
Parameter without subcode
CBn.b
n: 1 ~ 10000
b: 0 ~ 31
N/A
Parameter with subcode
CBn/y.b
n: 1 ~ 10000
b: 0 ~ 31
1 ~ 255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-54
Revision January 2008 Doc Name: 2007PDD23000007
Only VH type parameter can provide Bit read/write function (it is convenient for the user to read/write Bit No.
of parameters).
CBn.b, CWn (CWn.m), CDn (CDn.m): read/write address is the same (address n).
NOTE
1) Since the data format of this controller is complicated (a. VS (String format), b. VO (Octet string format
data blocks), c. VH (ASCII hexadecimal format)(1, 2, 4 bytes), d. VD (ASCII decimal format)(positive,
negative, decimal,..)) and the communication format is not compatible, therefore, it is needed to ensure
the HMI communication data format is correct, or an error may occur.
2) Registers: only can read/write the data of ASCII hexadecimal format (VH), ASCII decimal format (VD)
(i.e. Either VH or VD data format can be set via communication.)
Contacts: only can read/write the data of ASCII hexadecimal format (VH)
HMI display data format (Property table/Setting value...etc.) should also be correct.
Explanation:
y
Registers: only can read/write the data of VH, VD. HMI needs to set communication data format
(please refer to 4), 5) and 6)). String format (VS), and Octet string format for data blocks (VO) can
not be used. If the controller returns the data in VS or VO format, HMI will show “……Value Is
Incorrect” on the screen.
y
Contacts: only can read/write the data of ASCII hexadecimal format (VH). Only VH type parameter
can provide Bit read/write function. If the controller returns the data in other format, HMI will show
“……Value Is Incorrect” on the screen.
y
Do not write the inexistent Bit address, or HMI will show “….Write …. Command Can Not be
Executed” on the screen.
For example: CW470/1. The valid value of CW470/1 is within the range of 0 ~ 0xFF. Therefore, Bit
8 ~31 is not existed. Although HMI will show the value of Bit 8 ~31 is 0, the user can not write or set
the value.
y
The settings of ASCII hexadecimal format (VH) and ASCII decimal format (VD) should be correct. If
the VD data is set in VH format in HMI (m value is undefined, or m=22 or 23) or the VH data is set
in VD format in HMI (m=0 ~ 21), when HMI write the data, HMI will show “….Write …. Command
Can Not be Executed” on the screen or tell the user the write value is incorrect.
y
The decimal place of ASCII decimal format (VD) should be set correctly, or the write value will not
be correct. The decimal place displayed on HMI should also be correct, or the display value will be
incorrect.
y
ASCII hexadecimal format (VH), 2 numbers (m = 22). The value is limited to 2 numbers. Using this
format the write value will be limited within the range of 0 ~ 0xFF (low byte) automatically.
3) Station Number and Broadcast
y
The valid station number is from 0 to 99. If exceeds this range, HMI will stop read/write operation
and show “Controller Station Number Error …”on the screen.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 55
y
00 indicates the global broadcasting number (1~99).
y
10, 20, 30, 40, 50, 60, 70, 80, 90 are local broadcasting number.
The affected ranges are: 11~19, 21~29, 31~39, 41~49, 51~59, 61~69, 71~79, 81~89 and 91~99
respectively. Only choose setting value/setting constant (button), and then the broadcast function
can be used. If choosing other devices, the system will be confused while reading back the drive
setting value via broadcast function, so please ensure to choose the correct device. If choosing the
incorrect devices, a “Controller Station Number Error…” fault message will display on HMI screen.
y
Use in LECOM-A/B protocol. 82XX frequency AC drives and 93XX servo drives all use this protocol.
4) Explanation of communication error address
y
Registers: display CW n, CWy n, CD n, CDy n in order
y
Contacts: display CB n, CByn in order (n: address value)
5) HMI data format explanation
y
Some controller parameters are in Word and some are in Double Word. Therefore, there are two
kinds of data format: Word ( CWn (CWn.m), CWn/y(CWn/y.m) ) and Double Word ( CDn (CDn.m),
CDn/y(CDn/y.m) ).
y
Furthermore, regarding to Bit No., HMI only read/write 32Bit (Bit0 ~ Bit31) of parameters in VH
format.
y
CWn(CWn.m), CDn(CDn.m), or CBn.b: read/write address is the same (address n), but
When symbol is set to CW, read/write value is the low word of parameters (n) only,
When symbol is set to CD, read/write value is the Double Word of whole parameters (n),
When symbol is set to CB, read/write value is the Bit (b) No. of parameters (n).
(m : HMI communication data format)
y
(CWn/y(CWn/y.m), CDn/y(CDn/y.m), CBn/y.b: read/write address, which y subcode is the
same(address n), but
When symbol is set to CW, read/write value is the low word of parameters (n) only,
When symbol is set to CD, read/write value is the Double Word of whole parameters (n),
When symbol is set to CB, read/write value is the Bit (b) No. of parameters (n).
(m : HMI communication data format)
y
Actually when using HMI,
i)
When using devices that the unit is in Word (e.g. numeric devices (numeric value display,
numeric value input…)…), the read/write value will be the same no matter the read/write
address format is set to CWn or CDn as read/write value is the low word of parameters (n)
only.
ii)
When using devices that the unit is in Double Word (e.g. numeric devices (numeric value
display, numeric value input…)…), if the read/write address format is set to CWn,
read/write value is coming from the low word of CWn and CWn+1 these two addresses.
(The low word of CWn is regarded as “low word” and the low word of CWn+1 is regarded
as “high word”, and then combining “low word” and “high word” to a Double Word.)
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-56
Revision January 2008 Doc Name: 2007PDD23000007
If the read/write address format is set to CDn, read/write value is the whole Double Word
of CDn (1 address).
iii)
When using character device (e.g. character display, character input…), if the read/write
address format is set to CWn, the read/write value is coming from the low word of CWn,
CWn+1, CWn+2, …every address.
If the read/write address format is set to CDn, read/write value is the whole Double Word
of CDn, CDn+1, CDn+2,…every address.
iv)
When using “Multiple Duplicate” function, if the Word and Bit addresses exceed the valid
range, the Word and Bit addresses will be set to 0 automatically. Sometime error will
occur to remind the user when compiling.
v)
CBn.b, CBn/y.b are added for the user to read and write Bit No. of parameters in VH
format more easily.
vi)
Only can read or write 1 parameter for each communication.
C. Connections (Connector Pinouts)
Pin 2, 3, 5 are for RS-232 communication. Pin 7, 8 are for RS-485 communication.
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male
(RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) GND
Top View
RS-485
DOP
9 pin D-SUB male (RS-485)
Controller
9 pin D-SUB male (RS-485)
Controller
9 pin D-SUB male
(RS-485)
D- (1)
(7) T/R (A)
D+ (2)
D+ (3)
(8) T/R (B)
D- (4)
Top View
Pin1
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 57
LG Master K120S/200S
Back to Table
A. HMI factory settings
Baud rate: 38400, 8, None, 1. (RS-232)
Controller station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: DW0 / DW10.
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
WORD_DEVICE_PW
PWn
n: 0 ~ 15
N/A
Word
WORD_DEVICE_MW
MWn
n: 0 ~ 191
N/A
Word
WORD_DEVICE_KW
KWn
n: 0 ~ 31
N/A
Word
WORD_DEVICE_LW
LWn
n: 0 ~ 63
N/A
Word
WORD_DEVICE_FW
FWn
n: 0 ~ 63
N/A
Word
WORD_DEVICE_TW
TWn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_CW
CWn
n: 0 ~ 255
N/A
Word
WORD_DEVICE_DW
DWn
n: 0 ~ 9999
N/A
Word
Contacts
Contact type
Format
Word No.
Bit No.
BIT_DEVICE_P
Pnb
n: 0 ~ 15
b: 0 ~ f
BIT_DEVICE_M
Mnb
n: 0 ~ 191
b: 0 ~ f
BIT_DEVICE_K
Knb
n: 0 ~ 31
b: 0 ~ f
BIT_DEVICE_L
Lnb
n: 0 ~ 63
b: 0 ~ f
BIT_DEVICE_F
Fnb
n: 0 ~ 63
b: 0 ~ f
BIT_DEVICE_T
Tn
N/A
n: 0 ~ 255
BIT_DEVICE_C
Cn
N/A
n: 0 ~ 255
C. Connections (Connector Pinouts)
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-58
Revision January 2008 Doc Name: 2007PDD23000007
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller 9 pin D-SUB male
(RS-232 for LG K120S/200S)
Controller 9 pin D-SUB male
(RS-232 for LG K120S/200S)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) GND
Top View
NOTE
1) If connecting to Pin 4 (RXD), Pin 7 (TXD) and Pin5 (SG), it indicates that CNet protocol is used (Please
refer to the section “LG Master-K CNET”. 120S/200S protocol and CNet protocol cannot be used
simultaneously. The users only can select either 120S/200S protocol or CNet protocol.
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 59
LG Glofa GM6 CNET
Back to Table
A. HMI factory settings
Baud rate: 19200, 8, None, 1. (RS-232)
Controller station number: 0.
Control area/status area: %MW0 / %MW10.
NOTE
1) HMI default setting is predefined for CPU Port. If the user want to connect to CNET communication
module, the baud rate should be changed to 38400, 8, None, 1. (RS-422 / RS-485).
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
Input Image
IWb.s.w
w(word):0 ~ 3
s(slot): 0 ~ 7
b(base): 0 ~ 1
Word
Input Image
IDb.s.w
w(word):0 ~ 1
s(slot): 0 ~ 7
b(base): 0 ~ 1
DWord
Output Image
QWb.s.w
w(word):0 ~ 3
s(slot): 0 ~ 7
b(base): 0 ~ 1
Word
Output Image
QDb.s.w
w(word):0 ~ 1
s(slot): 0 ~ 7
b(base): 0 ~ 1
DWord
Internal Memory
MWn
n: 0 ~ 4095
N/A
Word
Internal Memory
MDn
n: 0 ~ 2047
N/A
DWord
Contacts
Contact type
Format
Word No.
Bit No.
Input Image
IXb.s.n
s(slot): 0 ~ 7
n(bit): 0 ~ 63
b(base): 0 ~ 1
Output Image
QXb.s.n
s(slot): 0 ~ 7
n(bit): 0 ~ 63
b(base): 0 ~ 1
Internal Memory
MXn
N/A
n: 0 ~ 65535
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-60
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
via CPU Port
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(7) TXD
TXD (3)
GND (5)
(4) RXD
(5) GND
Top View
RS-422
via G6L-CUEC CNET communication module
DOP
9 pin D-SUB male (RS-422)
Controller
Cable Connector (RS-422)
RXD+ (2)
SDA
RXD- (1)
TXD- (4)
SDB
RDB
TXD+ (3)
RDA
GND (5)
SG
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 61
LG Master-K CNET
Back to Table
A. HMI factory settings
Baud rate: 38400, 8, None, 1. (RS-422)
Controller station number: 0.
Control area/status area: DW0 / DW10.
NOTE
1) HMI default setting is predefined for G6L-CUEC CNET communication module.
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
I/O Relay
PWn
n: 0 ~ 31
N/A
Word
Auxiliary Relay
MWn
n: 0 ~ 191
N/A
Word
Keep Relay
KWn
n: 0 ~ 31
N/A
Word
Link Relay
LWn
n: 0 ~ 63
N/A
Word
Special Relay
FWn
n: 0 ~ 63
N/A
Word (Read Only)
Timer Elapsed Value
TWn
n: 0 ~ 255
N/A
Word
Counter Elapsed Value
CWn
n: 0 ~ 255
N/A
Word
Data Register
DWn
n: 0 ~ 9999
N/A
Word
Contacts
Contact type
Format
Word No.
Bit No.
I/O Relay
PXnb
n: 0 ~ 31
b: 0 ~ F
Auxiliary Relay
MXnb
n: 0 ~ 191
b: 0 ~ F
Keep Relay
KXnb
n: 0 ~ 31
b: 0 ~ F
Link Relay
LXnb
n: 0 ~ 63
b: 0 ~ F
Special Relay
FXnb
n: 0 ~ 63
b: 0 ~ F
Timer Contact Relay
TXb
N/A
b: 0 ~ 255
Counter Contact Relay
CXb
N/A
b: 0 ~ 255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-62
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-422
via G6L-CUEC CNET communication module
DOP
9 pin D-SUB male (RS-422)
Controller
Cable Connector (RS-422)
RXD+ (2)
SDA
RXD- (1)
TXD- (4)
SDB
RDB
TXD+ (3)
RDA
GND (5)
SG
RS-232
via LG-120S PLC (Master K)
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(7) TXD
TXD (3)
GND (5)
(4) RXD
(5) GND
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 63
LG XGT CNET
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, None, 1.
Controller station number: 0.
Control area/status area: DW0 / DW10.
NOTE
1) HMI default setting is predefined for XGL-CH2A CNET communication module.
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
I/O Relay
PWn
n: 0 ~ 2047
N/A
Word
Auxiliary Relay
MWn
n: 0 ~ 2047
N/A
Word
Keep Relay
KWn
n: 0 ~ 2047
N/A
Word
Link Relay
LWn
n: 0 ~ 11263
N/A
Word
Special Relay
FWn
n: 0 ~ 2047
N/A
Word (Read Only)
Timer Elapsed Value
TWn
n: 0 ~ 2047
N/A
Word
Counter Elapsed Value
CWn
n: 0 ~ 2047
N/A
Word
Data Register
DWn
n: 0 ~ 32767
N/A
Word
Contacts
Contact type
Format
Word No.
Bit No.
I/O Relay
PXnb
n: 0 ~ 2047
b: 0 ~ F
Auxiliary Relay
MXnb
n: 0 ~ 2047
b: 0 ~ F
Keep Relay
KXnb
n: 0 ~ 2047
b: 0 ~ F
Link Relay
LXnb
n: 0 ~ 11263
b: 0 ~ F
Special Relay
FXnb
n: 0 ~ 2047
b: 0 ~ F
Timer Contact Relay
TXb
N/A
b: 0 ~ 2047
Counter Contact Relay
CXb
N/A
b: 0 ~ 2047
Data Relay
DXn.b
n: 0 ~ 32767
b: 0 ~ F
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-64
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-422
via XGL-CH2A CNET communication module (Channel 2)
DOP
9 pin D-SUB male (RS-422)
Controller
Cable Connector (RS-422)
RXD+ (2)
TX+
RXD- ( 1)
TXD- (4)
TX-
RX-
TXD+ (3)
RX+
GND (5)
SG
RS-232
via XGL-CH2A CNET communication module (Channel 1)
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(3) TXD
T XD (3)
GND (5)
(2) RXD
(5) GND
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 65
LIYAN LYPLC EX
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller station number: 0.
Control area/status area: D0 / D10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Auxiliary Relay
Mn
n: 0 ~ 3064
N/A
Byte
Special Auxiliary Relay
Mn
n: 8000 ~ 8248
N/A
Byte
Status Relay
Sn
n: 0 ~ 992
N/A
Byte
Input Relay
Xn
n: 0 ~ 360(octal)
N/A
Byte
Output Relay
Yn
n: 0 ~ 360(octal)
N/A
Byte
Timer PV
Tn
n: 0 ~ 255
N/A
Word
16-bit Counter PV
Cn
n: 0 ~ 199
N/A
Word
32-bit Counter PV
Cn
n: 200 ~ 255
N/A
Double Word
Data Register
Dn
n: 0 ~ 7999
N/A
Word
Special Data Register
Dn
n: 8000 ~ 8255
N/A
Word
Auxiliary Relay / Special Auxiliary Relay / Status Relay / Input Relay / Output Relay: Address must be the
multiple of 8.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Auxiliary Relay
Mn
N/A
n: 0 ~ 3071
Special Auxiliary Relay
Mn
N/A
n: 8000 ~ 8255
Status Relay
Sn
N/A
n: 0 ~ 999
Input Relay
Xn
N/A
n: 0 ~ 377(octal)
Output Relay
Yn
N/A
n: 0 ~ 377(octal)
Timer Flag
Tn
N/A
n: 0 ~ 255
Counter Flag
Cn
N/A
n: 0 ~ 255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-66
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
Controller
8 pin Mini DIN male (RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(7) RXD
(3) GND
(6) GND
Top View
2
3
6
7
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 67
M2i Master
Back to Table
A. HMI factory settings
Baud rate: 38400, 8, None, 1.
Controller station number: 1.
Control area/status area: SB0 / SB10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Word Address
SBn
n: 0000 ~ FFFF
N/A
Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Bit Address
SBn.b
n: 0000 ~ FFFF
b: 0 ~ F
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-68
Revision January 2008 Doc Name: 2007PDD23000007
M2i Slave
Back to Table
A. HMI factory settings
Baud rate: 38400, 8, None, 1.
Controller station number: 1 (no function)
Control area/status area: SB0 / SB10.
NOTE
1) HMI station number is Slave station number. (default setting is 0)
2) The relation between M2i communication address and HMI internal registers.
Modbus address
Data definition in HMI
SB0000 ~ SB7FFF
$0 ~ $32767
SB8000 ~ SB83FF
$M0 ~ $M1023
SB8400
RCPNO
SB8500 ~ SBFFFF
RCP0 ~ RCP31487
B. Definition of controller Read/Write address
Registers
Register Type
Format
Word No.
Bit No.
Data Size
Word Address
SBn
n: 0000 ~ FFFF
N/A
Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Bit Address
SBn.b
n:0000 ~ FFFF
b: 0 ~ F
C. Connections (Connector Pinouts):
Please refer to 1.1 Pin Definition of Serial Communication for detail.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 69
Matsushita FP PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, ODD, 1.
Controller station number: 238.
Control area/status area: DT0 / DT10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Internal Relay
WRn
n: 0 ~ 886,
N/A
Word
Special Internal Relay
900 ~ 910
Link Relay
WLn
n: 0 ~ 639
N/A
Word
External Input Relay
WXn
n: 0 ~ 511
N/A
Word
External Output Relay
WYn
n: 0 ~ 511
N/A
Word
Timer/Counter P.V.
EVn
n: 0 ~ 3071
N/A
Word
Timer/Counter S.V.
SVn
n: 0 ~ 3071
N/A
Word
Data Register
DTn
n: 0 ~ 32764
N/A
Word
Link Data Register
LDn
n: 0 ~ 8447
N/A
Word
File Register
FLn
n: 0 ~ 32764
N/A
Word
Special Data Register
DT9_n
n: 0 ~ 511
N/A
Word
¾ DT9_0 ~ DT9_511 are applicable for FP0 T32C, FP2, FP2SH, FP10SH controllers. (Special data
registers are all within the range of DT90000 ~ DT9XXXX).
¾ The actual transmitted address of DT9_n is 90000 + n (for DT). For example, the actual transmitted
address of DT9_1 is 90001 (for DT), the actual transmitted address of DT9_2 is 90002 (for DT) and vise
versa.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Internal Relay
Rnb
n: 0 ~ 886
b: 0 ~ f
Special Internal Relay
n: 900 ~ 910
b: 0 ~ f
Link Relay
Lnb
n: 0 ~ 639
b: 0 ~ f
External Input Relay
Xnb
n: 0 ~ 511
b: 0 ~ f
External Output Relay
Ynb
n: 0 ~ 511
b: 0 ~ f
Timer Flag Contact
Tn
N/A
n: 0 ~ 3071
Counter Flag Contact
Cn
N/A
n: 0 ~ 3071
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-70
Revision January 2008 Doc Name: 2007PDD23000007
¾ Increase the range of read / write address (for FP2SH / FP10SH controllers).
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male
(RS-232)
Controller
5 pin Mini DIN male
(RS-232 for FP0)
Controller
5 pin Mini DIN male
(RS-232 for FP0)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(1) SG
Top View
RS-232
DOP Series
9 pin D-SUB male
(RS-232)
Controller
9 pin D-SUB male
(RS-232 for FP1)
Controller
9 pin D-SUB male
(RS-232 for FP1)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(7) GND
(4) RTS
(5) CTS
Top View
1
2
3
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 71
Mirle FAMA SC
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller station number: 0.
Control area/status area: 40100 / 40200.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
Output Registers
Wn
n: 40001 ~ 50000
N/A
Word
Input Registers
Wn
n: 30001 ~ 40000
N/A
Word
¾ Input Registers is “read only”.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Discrete Outputs
Bn
N/A
n: 1 ~ 10000
Discrete Inputs
Bn
N/A
n: 10001 ~ 20000
¾ Discrete Inputs is “read only”.
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male
(RS-232)
Controller
9 pin D-SUB male
(RS-232)
Controller
9 pin D-SUB male
(RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-72
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi FX/FX2N PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: D0 / D10.
NOTE
1) If connecting to Mitsubishi FXxN series PLC, the user can use both FX2N and FX series communication
protocol.
2) If connecting to Mitsubishi FX series PLC, the user can only use FX series communication protocol.
3) Some registers of Mitsubishi PLCs are “read only”, however, when you write these “read only” registers,
PLCs will not report any communication error to HMI and this will cause HMI errors. Please be aware of
this when editing PLC program (this normally occurs when using FX series protocol when connecting to
a FXxN series PLC).
4) If connecting to Mitsubishi FXxN series PLC, it is recommended for the user to use FX2N protocol.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Auxiliary Relay
Mn
n: 0 ~ 3064
N/A
Byte
Special Auxiliary Relay
Mn
n: 8000 ~ 8248
N/A
Byte
Status Relay
Sn
n: 0 ~ 992
N/A
Byte
Input Relay
Xn
n: 0 ~ 360(octal)
N/A
Byte
Output Relay
Yn
n: 0 ~ 360(octal)
N/A
Byte
Timer PV
Tn
n: 0 ~ 255
N/A
Word
16-bit Counter PV
Cn
n: 0 ~ 199
N/A
Word
32-bit Counter PV
Cn
n: 200 ~ 255
N/A
Double Word
Data Register
Dn
n: 0 ~ 7999
N/A
Word
Special Data Register
Dn
n: 8000 ~ 8255
N/A
Word
¾ Auxiliary Relay/ Special Auxiliary Relay/ Status Relay/ Input Relay /Output Relay: Address must be the
multiple of 8.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 73
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Auxiliary Relay
Mn
N/A
n: 0 ~ 3071
Special Auxiliary Relay
Mn
N/A
n: 8000 ~ 8255
Status Relay
Sn
N/A
n: 0 ~ 999
Input Relay
Xn
N/A
n: 0 ~ 377(octal)
Output Relay
Yn
N/A
n: 0 ~ 377(octal)
Timer Flag
Tn
N/A
n: 0 ~ 255
Counter Flag
Cn
N/A
n: 0 ~ 255
C. Connections (Connector Pinouts)
RS-422
DOP Series
9 pin D-SUB male (RS-422)
Controller
8pin Mini DIN male (RS-422)
Controller
8pin Mini DIN male
(RS-422)
RXD+ (2)
(7) TXD+
RXD- (1)
TXD+ (3)
(4) TXD-
(2) RXD+
TXD- (4)
(1) RXD-
GND (5)
(3) SG
Top View
RS-422
DOP
9 pin D-SUB male (RS-422)
Controller
25 pin D-SUB male (RS-422)
Controller
25 pin D-SUB male (RS-422)
Pin 2 ( RXD+)
Pin3 SDB ( TXD+)
Pin 1 ( RXD-)
Pin 4 ( TXD-)
Pin16 SDA (TXD-)
Pin 15 RDA (RXD-)
Pin 3 ( TXD+)
Pin 2 RDB (RXD+)
Pin 7 ( RTS+)
Pin4 (CTS+)
Pin 8 ( CTS+)
Pin 6 ( RTS-)
Pin5 (RTS+)
Pin 17 (CT S-)
Pin 9 ( CTS-)
Pin 18 (RTS-)
Pin 20
Pin 21
1
4
7
2
3
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-74
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi FX3U PLC
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: D0 / D10.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Auxiliary Relay
Mn
n: 0 ~ 7679
N/A
Word
Special Auxiliary Relay
Mn
n: 8000 ~ 8511
N/A
Word
Status Relay
Sn
n: 0 ~ 4095
N/A
Word
Input Relay
Xn
n: 0 ~ 377(octal)
N/A
Word
Output Relay
Yn
n: 0 ~ 377(octal)
N/A
Word
Timer PV
Tn
n: 0 ~ 255
N/A
Word
16-bit Counter PV
Cn
n: 0 ~ 199
N/A
Word
32-bit Counter PV
Cn
n: 200 ~ 255
N/A
Double Word
Data Register
Dn
n: 0 ~ 7999
N/A
Word
Special Data Register
Dn
n: 8000 ~ 8511
N/A
Word
¾ Auxiliary Relay/ Special Auxiliary Relay/ Status Relay/ Input Relay /Output Relay: Address must be the
multiple of 16.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Auxiliary Relay
Mn
N/A
n: 0 ~ 7679
Special Auxiliary Relay
Mn
N/A
n: 8000 ~ 8511
Status Relay
Sn
N/A
n: 0 ~ 4095
Input Relay
Xn
N/A
n: 0 ~ 377(octal)
Output Relay
Yn
N/A
n: 0 ~ 377(octal)
Timer Flag
Tn
N/A
n: 0 ~ 255
Counter Flag
Cn
N/A
n: 0 ~ 255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 75
C. Connections (Connector Pinouts)
RS-422
DOP Series
9 pin D-SUB male (RS-422)
Controller
8pin Mini DIN male (RS-422)
Controller
8pin Mini DIN male
(RS-422)
RXD+ (2)
(7) TXD+
RXD- (1)
TXD+ (3)
(4) TXD-
(2) RXD+
TXD- (4)
(1) RXD-
GND (5)
(3) SG
Top View
1
4
7
2
3
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-76
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi A Series AJ71UC24 Communication Module
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, ODD, 1.
Controller Station number: 0.
Control area/status area: D0 / D10.
NOTE
1) This driver utilizes CheckSum.
2) Please set “PLC Mode” switch to position 5.
3) If OUTPUT Relay (Y) and Special Data Relay (SM) are set to 1, PLC will stop communication and the
communication will not recover automatically. PLC will need to be manually reset.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Input
Xn
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Output
Yn
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Link Relay
Bn
n: 0 ~ FFF
N/A
Word (multiple of 16)
Internal Relay
Mn
n: 0 ~ 8191
N/A
Word (multiple of 16)
Special Internal Relay
SMn
n: 9000 ~ 9255
N/A
Word (9000 + multiple of 16)
Latch Relay
Ln
n: 0 ~ 2047
N/A
Word (multiple of 16)
Annunciator
Fn
n: 0 ~ 2047
N/A
Word (multiple of 16)
Timer Value
TNn
n: 0 ~ 999
N/A
Word
Counter Value
CNn
n: 0 ~ 999
N/A
Word
Data Register
Dn
n: 0 ~ 8191
N/A
Word
Special Data Register
SDn
n: 9000 ~ 9255
N/A
Word
File Register
Rn
n: 0 ~ 8191
N/A
Word
Link Register
Wn
n: 0 ~ FFF
N/A
Word
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 77
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input
Xn
N/A
n: 0 ~ 7FF
Output
Yn
N/A
n: 0 ~ 7FF
Link Relay
Bn
N/A
n: 0 ~ FFF
Internal Relay
Mn
N/A
n: 0 ~ 8191
Special Internal Relay
SMn
N/A
n: 9000 ~ 9255
Latch Relay
Ln
N/A
n: 0 ~ 2047
Annunciator
Fn
N/A
n: 0 ~ 2047
Timer Contact
TSn
N/A
n: 0 ~ 999
Timer Coil
TCn
N/A
n: 0 ~ 999
Counter Contact
CSn
N/A
n: 0 ~ 999
Counter Coil
CCn
N/A
n: 0 ~ 999
C. Connections (Connector Pinouts)
RS-422
DOP
9 pin D-SUB male (RS-422)
Controller
Cable Connector (RS-422)
RXD+ (2)
SDA
RXD- (1)
TXD+ (3)
SDB
RDA
TXD- (4)
RDB
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-78
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi A2A/A2AS/A2USH A1SH/A3N/A2ASH (CPU-S1) CPU Port
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, ODD, 1.
Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: D0 / D10.
NOTE
1) This driver supports all Mitsubishi A series CPU port. Mitsubishi A series CPU port can be divided into
the following five categories according the used CPU code (used during communication):
y
A0J2…
y
A1N…
y
A1S ( / A2S / A2N …)
y
A3N ( / A1SH / A2SH …)
y
A2A ( / A2AS / A2USH …)
Delta HMI can support A2USH CPU port (same as A2A, A2AS CPU port.) and A1SH CPU port (same as
A3N, A2ASH CPU port.).
2) L and M: The communication address of L is the same as communication address of M.
3) PX and X:
In Mitsubishi A2A PLC, the communication address of PX and X are the same.
In other Mitsubishi A series PLCs, X is from odd address and PX is from even address. That is one place
where PX and X differ.
4) X, Y, B, M, SM, L, F, PX ----(Word),
X, Y, B, M, SM, L, F, PX ----(Bit),
When PLC station number is set to 255, only the value of even addresses will be read/written.
When PLC station number is set to other number (not 255), all value of all addresses will be read/written.
5) R address: R address will be different according to the size of File Register responded from PLC.
For example, A2USH:
1K: 3800 ~ 4000H
2K: 3000 ~ 4000H
3K: 2800 ~ 4000H
4K: 2000 ~ 4000H
5K: 4000 ~ 6800H(cy)
6K: 4000 ~ 7000H(cy)
File Register: PLC must be started correctly or the read / write value will be incorrect.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 79
6) Max. read/write registers & relays for communication once
128 Words (256 bytes) Registers
64 Words (128 bytes) Relays
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Input
Xn
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Output
Yn
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Link Relay
Bn
n: 0 ~ FFF
N/A
Word (multiple of 16)
Internal Relay
Mn
n: 0 ~ 8191
N/A
Word (multiple of 16)
Special Internal Relay
SMn
n: 9000 ~ 9255
N/A
Word (9000 + multiple of 16)
Latch Relay
Ln
n: 0 ~ 8191
N/A
Word (multiple of 16)
Annunciator
Fn
n: 0 ~ 2047
N/A
Word (multiple of 16)
Timer Value
TNn
n: 0 ~ 2047
N/A
Word
Counter Value
CNn
n: 0 ~ 1023
N/A
Word
Data Register
Dn
n: 0 ~ 8191
N/A
Word
Special Data Register
SDn
n: 9000 ~ 9255
N/A
Word
File Register
Rn
n: 0 ~ 8191
N/A
Word
Link Register
Wn
n: 0 ~ FFF
N/A
Word
Input Card Register
PXn
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input
Xn
N/A
n: 0 ~ 7FF
Output
Yn
N/A
n: 0 ~ 7FF
Link Relay
Bn
N/A
n: 0 ~ FFF
Internal Relay
Mn
N/A
n: 0 ~ 8191
Special Internal Relay
SMn
N/A
n: 9000 ~ 9255
Latch Relay
Ln
N/A
n: 0 ~ 2047
Annunciator
Fn
N/A
n: 0 ~ 2047
Timer Contact
TSn
N/A
n: 0 ~ 2047
Timer Coil
TCn
N/A
n: 0 ~ 2047
Counter Contact
CSn
N/A
n: 0 ~ 1023
Counter Coil
CCn
N/A
n: 0 ~ 1023
Input Card Register
PXn
N/A
n: 0 ~ 7FF
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-80
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-422
DOP Series
9 pin D-SUB male (RS-422)
Controller
25 pin D-SUB male (RS-422)
Controller
25 pin D-SUB male(RS-422)
Pin 2 ( RXD+)
Pin3 SDB ( TXD+)
Pin 1 ( RXD-)
Pin 4 ( TXD-)
Pin16 SDA (TXD-)
Pin 15 RDA (RXD-)
Pin 3 ( TXD+)
Pin 2 RDB (RXD+)
Pin 7 ( RTS+)
Pin4 (CTS+)
Pin 8 ( CTS+)
Pin 6 ( RTS-)
Pin5 (RTS+)
Pin 17 (CT S-)
Pin 9 ( CTS-)
Pin 18 (RTS-)
Pin 20
Pin 21
Explanation
How to set File Register (R) for Mitsubishi A serial PLC:
1. Startup MELSOFT series GX Developer.
2. Open “Project Data List” windows. (“View” Option)
3. Double click Parameter \ PLC Parameter, and open “Setting” window.
4. Set Memory Capacity \ File Register (0 ~8).
5. Press “End” button on the bottom and complete the setting.
6. Execute OnLine\Write to PLC.
7. Enable the “Parameter \ PLC/Network” and “File register \ Main” option (check the check box next to
“Parameter \ PLC/Network” and “File register \ Main”).
8. Press “Execute” button.
9. Complete
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 81
Mitsubishi Q Series CPU Port
Back to Table
A. HMI factory settings
Baud rate: 19200, 8, ODD, 1.
Controller Station number: 0. (no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC)
communication is allowed.)
Control area/status area: D-0 / D-10.
NOTE
1) Please notice that no PLC station number in protocol, therefore, only 1(HMI) to 1 (PLC) communication
is allowed.
2) If communication baud rate is not correct, HMI will set PLC baud rate as HMI baud rate automatically.
Therefore, do not worry if the baud rate is set incorrectly.
3) This driver support Mitsubishi Q00 and Q00J series with password protection models.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Input
X-n
n: 0 ~ 1FFF
N/A
Word (multiple of 16)
Output
Y-n
n: 0 ~ 1FFF
N/A
Word (multiple of 16)
Direct Input
DX-n
n: 0 ~ 1FFF
N/A
Word (multiple of 16)
Direct Output
DY-n
n: 0 ~ 15
N/A
Word (multiple of 16)
Latch Relay
L-n
n: 0 ~ 8191
N/A
Word (multiple of 16)
Annunciator
F-n
n: 0 ~ 2047
N/A
Word (multiple of 16)
Edge Relay
V-n
n: 0 ~ 2047
N/A
Word (multiple of 16)
Step Relay
S-n
n: 0 ~ 8191
N/A
Word (multiple of 16)
Link Relay
B-n
n: 0 ~ 1FFF
N/A
Word (multiple of 16)
Special Link Relay
SB-n
n: 0 ~ 7FF
N/A
Word (multiple of 16)
Internal Relay
M-n
n: 0 ~ 8191
N/A
Word (multiple of 16)
Special Internal Relay
SM-n
n: 0 ~ 2047
N/A
Word (multiple of 16)
Timer Value
TN-n
n: 0 ~ 2047
N/A
Word
Retentive Timer Value
SN-n
n: 0 ~ 2047
N/A
Word
Counter Value
CN-n
n: 0 ~ 1023
N/A
Word
Data Register
D-n
n: 0 ~ 12287
N/A
Word
Special Data Register
SD-n
n: 0 ~ 2047
N/A
Word
Index Register
Z-n
n: 0 ~ 15
N/A
Word
File Register
R-n
n: 0 ~ 32767
N/A
Word
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-82
Revision January 2008 Doc Name: 2007PDD23000007
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
File Register
ZR-n
n: 0 ~ 32767
N/A
Word
Link Register
W-n
n: 0 ~ 1FFF
N/A
Word
Special Link Register
SW-n
n: 0 ~ 7FF
N/A
Word
¾ Xn, Yn, DXn, Bn, SBn, Wn, SWn : n is in hexadecimal.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input
X-n
N/A
n: 0 ~ 1FFF
Output
Y-n
N/A
n: 0 ~ 1FFF
Direct input
DX-n
N/A
n: 0 ~ 1FFF
Direct output
DY-n
N/A
n: 0 ~ 15
Latch Relay
L-n
N/A
n: 0 ~ 8191
Annunciator
F-n
N/A
n: 0 ~ 2047
Edge Relay
V-n
N/A
n: 0 ~ 2047
Step Relay
S-n
N/A
n: 0 ~ 8191
Link Relay
B-n
N/A
n: 0 ~ 1FFF
Special Link Relay
SB-n
N/A
n: 0 ~ 7FF
Internal Relay
M-n
N/A
n: 0 ~ 8191
Special Internal Relay
SM-n
N/A
n: 0 ~ 2047
Timer Contact
TS-n
N/A
n: 0 ~ 2047
Timer Coil
TC-n
N/A
n: 0 ~ 2047
Retentive timer Contact
SS-n
N/A
n: 0 ~ 2047
Retentive timer Coil
SC-n
N/A
n: 0 ~ 2047
Counter Contact
CS-n
N/A
n: 0 ~ 1023
Counter Coil
CC-n
N/A
n: 0 ~ 1023
¾ Xn, Yn, DXn, Bn, SBn : n is in hexadecimal.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 83
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
6 pin Mini DIN male (RS-232)
Controller
6 pin Mini DIN male
(RS-232)
RXD (2)
(2) SD (TXD)
TXD (3)
GND (5)
(1) RD (RXD)
(3) GND
(5) DSR (DR)
(6) DTR (ER)
Top View
2
6 5
3
1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-84
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi Q Series Computer Link
Back to Table
A. HMI factory settings
Baud rate: 19200, 8, None, 1.
Controller Station number: 0.
Control area/status area: D0 / D10.
NOTE
1) This communication protocol supports Q series RS232 communication module (QJ71C24-R2) and
RS422 communication protocol (QJ71C24N).
2) Before using this communication protocol, the user needs to set communication module via PC software ,
GX Developer. For more detailed information regarding the setting method, please refer to Mitsubishi
User Manual named “User’s Manual (Basic) - Q Corresponding Series Communication Module”.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Input
Xn
n: 0-1FFF
N/A
Word (multiple of 16)
Output
Yn
n: 0-1FFF
N/A
Word (multiple of 16)
Internal Relay
Mn
n: 0-8191
N/A
Word (multiple of 16)
Special Internal Relay
Mn
n: 9000-9255
N/A
Word (9000 + multiple of 16)
Link Relay
Bn
n: 0-1FFF
N/A
Word (multiple of 16)
Annunciator
Fn
n: 0-2047
N/A
Word (multiple of 16)
Timer Value
TNn
n: 0-2047
N/A
Word
Counter Value
CNn
n: 0-2047
N/A
Word
Data Register
Dn
n: 0-8191
N/A
Word
Special Data Register
Dn
n: 9000-9255
N/A
Word
Link Register
Wn
n: 0-1FFF
N/A
Word
¾ Xn, Yn, Bn, Wn : n is in hexadecimal.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input
Xn
N/A
n: 0-1FFF
Output
Yn
N/A
n: 0-1FFF
Internal Relay
Mn
N/A
n: 0-8191
Special Internal Relay
Mn
N/A
n: 9000-9255
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 85
Read/Write Range
Contact type
Format
Word No.
Bit No.
Link Relay
Bn
N/A
n: 0-1FFF
Annunciator
Fn
N/A
n: 0-2047
Timer Contact
TSn
N/A
n: 0-2047
Timer Coil
TCn
N/A
n: 0-2047
Counter Contact
CS-n
N/A
n: 0-2047
Counter Coil
CC-n
N/A
n: 0-2047
¾ Xn, Yn, Bn : n is in hexadecimal.
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(5) SG
(8) RTS
(7) CTS
(4) DSR (DR)
(6) DTR (ER)
Top View
RS-422
DOP
9 pin D-SUB male (RS-422)
Controller
Cable Connector (RS-422)
RXD+ (2)
SDA ( 1)
RXD- (1)
TXD+ (3)
SDB ( 2)
RDA ( 3)
TXD- (4)
RDB (4)
GND (5)
SG
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-86
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi FX Series PLC via Computer Link
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 0.
Control area/status area: D0 / D10.
NOTE
1) This communication protocol supports FX series RS485 and RS232 communication module.
2) The default setting of this communication protocol is to support RS485 communication module. If the
user needs to use RS232 communication module, the user must change the communication setting from
RS485 to RS232 manually.
3) For more detailed information regarding the communication setting method, please refer to Mitsubishi
Communication User Manual named “User’s Manual - Data Communication Edition”.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Auxiliary Relay
Mn
n: 0-7679
N/A
Word
Special Auxiliary Relay
Mn
n: 8000-8511
N/A
Word
Status Relay
Sn
n: 0-4095
N/A
Word
Input Relay
Xn
n: 0-377(octal)
N/A
Word
Output Relay
Yn
n: 0-377(octal)
N/A
Word
Timer PV
Tn
n: 0-255
N/A
Word
16-bit Counter PV
Cn
n: 0-199
N/A
Word
32-bit Counter PV
Cn
n: 200-255
N/A
Double Word
Data Register
Dn
n: 0-7999
N/A
Word
Special Data Register
Dn
n: 8000-8511
N/A
Word
¾ Auxiliary Relay / Special Auxiliary Relay / Status Relay / Input Relay / Output Relay: Address must be
the multiple of 16.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Auxiliary Relay
Mn
N/A
n: 0-7679
Special Auxiliary Relay
Mn
N/A
n: 8000-8511
Status Relay
Sn
N/A
n: 0-4095
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 87
Read/Write Range
Contact type
Format
Word No.
Bit No.
Input Relay
Xn
N/A
n: 0-377(octal)
Output Relay
Yn
N/A
n: 0-377(octal)
Timer Flag
Tn
N/A
n: 0-255
Counter Flag
Cn
N/A
n: 0-255
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
TXD (3)
TXD ( 3)
GND (5)
RXD (2 )
GND (5)
Top View
RS-485
DOP
9 pin D-SUB male (RS-485)
Controller
Communication Module
D- (1)
SDB
D- (4)
D+ (2)
RDB
SDA
D+ (3)
RDA
GND (5)
GND
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-88
Revision January 2008 Doc Name: 2007PDD23000007
Mitsubishi J2s Series Servo
Back to Table
A. HMI factory settings
Baud rate: 9600, 8, Even, 1 (RS-232).
Controller Station number: 0.
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Parameter List
(cmd: 05/84) (NOTE 1)
Pn
n: 0 – 84
N/A
Double word
Status Display
(cmd: 01,8n/NA) (NOTE 1)
Sn
n: 0 – E
N/A
Double word
Alarm Number in history
(cmd: 33,1n/NA) (NOTE 1)
ANn
n: 0 – 5
N/A
Word
Alarm Occurrence time in history (AO)
(cmd: 33,2n/NA) (NOTE 1)
AOn
n: 0 – 5
N/A
Double word
Current Alarm Number (AC)
(cmd: 02/NA) (NOTE 1)
ACn
n: 0
N/A
Word
Status Display at alarm occurrence (AS)
(cmd: 35,8/NA) (NOTE 1)
ASn
n: 0
N/A
Double word
External input pin status (EI)
(cmd: 12,40/92,00) (NOTE 1)
EIn
n: 0
N/A
Double word
External output pin status (EO)
(cmd: 12,C0/92,A0) (NOTE 1)
EOn
n: 0
N/A
Double word
Operation mode selection (OP)
(cmd: NA/8B,00) (NOTE 1)
OPn
n: 0
N/A
Word
Speed for test operation (TSPD)
(cmd: NA/A0,10) (NOTE 1)
TSPDn
n: 0
N/A
Word
Acceleration/deceleration for test
operation (TACC)
(cmd: NA/A0,11) (NOTE 1)
TACCn
n: 0
N/A
Double word
Distance for test operation (TDIS)
(cmd: NA/A0,13) (NOTE 1)
TDISn
n: 0
N/A
Double word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Status display clear (SRST)
(cmd: NA/81,00)
(NOTE 1)
SRSTb
N/A
b: 0
Alarm history clear (ACLR)
(cmd: NA/82,20)
(NOTE 1)
ACLRb
N/A
b: 0
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 89
Read/Write Range
Contact type
Format
Word No.
Bit No.
Alarm reset (ARST)
(cmd: NA/82,00)
(NOTE 1)
ARSTb
N/A
b: 0
Turn off the external input signals (DI) (OFDI)
(cmd: NA/90,00)
(NOTE 1)
OFDIb
N/A
b: 0
Changes the external output signals (DO) (CHDO)
(cmd: NA/90,03)
(NOTE 1)
CHDOb
N/A
b: 0
Enable the disabled external input signals (ENDI)
(cmd: NA/90,10)
(NOTE 1)
ENDIb
N/A
b: 0
Enable the disabled external output signals (ENDO)
(cmd: NA/90,13)
(NOTE 1)
ENDOb
N/A
b: 0
Clear the time constant of acceleration in test
operation mode (TCLR)
(cmd: NA/A0,12)
(NOTE 1)
TCLRb
N/A
b: 0
Temporary stop of position mode in test operation
(TSTP)
(cmd: NA/A0,15)
(NOTE 1)
TSTPb
N/A
b: 0
C. Connections (Connector Pinouts)
RS-232
DOP Series
9 pin D-SUB male (RS-232)
Controller
20 pin CN3
GND (5 )
GND (1)
GND (11)
RXD (2 )
TXD ( 12)
TXD (3)
RXD (2)
NOTE
1) Read / Write Limit
This communication protocol uses devices to simulate the operation of Servo, so there is a limit for the
device to read and write the command. In the column of register type and contact type, the string of
characters after “cmd:” indicates the corresponding Servo command that the device will read and write.
For example, the string of characters after “cmd:” of the register, Status display is 01,8n/NA. It means
that the device can read it but cannot write it. One more example, the string of characters after “cmd:” of
the Operation mode selection (OP) is N/A/8B,00. It means that the device can write it but cannot read it.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-90
Revision January 2008 Doc Name: 2007PDD23000007
MKS BY125 Low Cost Synchrocontroller
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 11 (NOTE 1).
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
n: 0 ~ 17,
40 ~ 41,
45 ~ 48,
50,
Data In Register / Setup
Register
Cn
90 ~ 92
N/A
Double Word
Synchronizing (Differential
Counter)
SYN_ERRn
n: 0
N/A
Double Word
Integration register
IRn
n: 0
N/A
Double Word
Actual Master speed
MAS_SPDn
n: 0
N/A
Double Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Reset
RSTn
N/A
n: 0
Jog Trim+
JOGTRIM_INCn
N/A
n: 0
Jog Trim-
JOGTRIM_DECn
N/A
n: 0
Activate Data
ACT_DATAn
N/A
n: 0
Store EEPROM
STR_EEPROMn
N/A
n: 0
Index Slave
IND_SLAn
N/A
n: 0
Index Master
IND_MASn
N/A
n: 0
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 91
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
20 pin CN3
Controller
20 pin CN3
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
Top View
RS-485
DOP
9 pin D-SUB male (RS-485)
Controller
Controller
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
Top View
NOTE
1) The valid station number is in the range of 11 to 99. However, 20, 30, 40, 50, 60, 70, 80 and 90 cannot
be used as they are all broadcast station number.
00 for all broadcast
10 for the broadcast to 11 ~ 19
20 for the broadcast to 21 ~ 29
and vise versa.
2) Now the broadcast function is not provided, therefore, 20, 30, 40, 50, 60, 70, 80 and 90 cannot be used.
3) Only one data (1 Word/ 1 Double Word / 1 Bit) can be read and written for each communication. So, the
“Optimize” (Optimization for reading) selection in “Communication” tab in the “Configuration” dialog box
in “Options” menu (Options Æ Configuration Æ Communication) is cancelled.
4) When using RS-232 communication, the user only can use 3 pins (Pin 2, Pin 3 and Pin 5). DO NOT use
5 pins for RS-232 communication. Also, Pin 9 is for +5V. Do not confuse and connect to the wrong pin;
otherwise the serious damage may occur.
5) The effective addresses of Cn are not consecutive (5 blocks: C0~17, C40~41, C45~C48, C50,
C90~C92). When setting the addresses, do not exceed the block range. For example, when using a
Numeric Entry or Character Entry element, if the address is C15, the data length only can be 6 Words
Pin1
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-92
Revision January 2008 Doc Name: 2007PDD23000007
(C15, C16, C17). If the data length is out of this range, i.e. occupy other addresses except C0~C17, an
error may occur.
6) The effective addresses of Cn are not consecutive (5 blocks: C0~17, C40~41, C45~C48, C50,
C90~C92). However, when executing duplicate function (Decrease Address), the addresses will be
regarded as consecutive addresses. For example, the next address of C90 is C50; the next address of
C50 is C48; the next address of C45 is C41; the next address of C40 is C17.
7) When all Word address is written, the controllers all response ACK(0x06). But when all Word address is
read, the receive value will not change. The user needs to press ACT_DATA0 again and then the
receive value will be updated.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 93
MKS CT150
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, E, 1. (RS-232)
Controller Station number: 11.
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data In Register
Cn
n: 0 ~ 25
N/A
Setup Register
Cn
n: 40 ~ 43
N/A
45 ~ 50
90 ~ 97
Error Count
Err_CNT
0
N/A
LV Value
LV_VAL
0
N/A
Printmark Error
PRTMARK_ERR
0
N/A
Batch Counter
BAT_CNT
0
N/A
Waste Counter
WASTE_CNT
0
N/A
Line Speed
LINE_SPD
0
N/A
Actual Cutting Length
ACT_CUT_LEN
0
N/A
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Reset
RST
N/A
0
Jog Trim+
JOGTRIM_INC
N/A
0
Jog Trim-
JOGTRIM_DEC
N/A
0
Read PI
READ_PI
N/A
0
Activate Data
ACT_DATA
N/A
0
Store Eeprom
STR_EEPROM
N/A
0
Start/Stop
START_STOP
N/A
0
Reset Mark Counter
RSTMARK_CNT
N/A
0
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-94
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) SG
Top View
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 95
MKS MC700/720 Motion Controller
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1.
Controller Station number: 11 (NOTE 1).
Control area/status area: None / None.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data Length
General Parameters
GPn
n: 0 ~ 31
N/A
Double Word
Parameter Block for Slave 1
PB1_n
n: 0 ~ 31
N/A
Double Word
Parameter Block for Slave 2
PB2_n
n: 0 ~ 31
N/A
Double Word
Parameter Block for Slave 3
PB3_n
n: 0 ~ 31
N/A
Double Word
Parameter Block for Slave 4
PB4_n
n: 0 ~ 31
N/A
Double Word
Process Data
PRODn
n: 0 ~ 31
N/A
Double Word
Communication Settings
CSETn
n: 0 ~ 31
N/A
Double Word
Setup Settings
STUPn
n: 0 ~ 31
N/A
Double Word
Status of Commands and
Outputs
S_COn
n: 0 ~ 4
N/A
Double Word
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Commands
CMDb
N/A
b: 0 ~ 31
Outputs
OUTb
N/A
b: 0 ~ 31
Status of Commands and
Outputs
S_COn.b
n: 0 ~ 4
b: 0 ~ 31
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-96
Revision January 2008 Doc Name: 2007PDD23000007
C. Connections (Connector Pinouts)
RS-232
DOP
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
Controller
9 pin D-SUB male (RS-232)
RXD (2)
(3) TXD
TXD (3)
GND (5)
(2) RXD
(5) GND
Top View
RS-422
DOP
9 pin D-SUB male (RS-422)
Controller
9 pin D-SUB male (RS-422)
Controller
9 pin D-SUB male (RS-422)
RXD- (1)
(7)T-
RXD+ (2)
TXD+ (3)
(8)T+
(6)R+
TXD- (4)
(1)R-
Top View
RS-485
DOP
9 pin D-SUB male (RS-485)
DOP
9 pin D-SUB male (RS-485)
DOP
9 pin D-SUB male (RS-485)
D+ (2)
T+ (8)
D+ (3)
D- (1)
T-(7)
D- (4)
Top View
NOTE
1) The valid station number is in the range of 11 to 99. However, 20, 30, 40, 50, 60, 70, 80 and 90 cannot
be used as they are all broadcast station number.
00 for all broadcast
10 for the broadcast to 11 ~ 19
20 for the broadcast to 21 ~ 29
and vise versa.
2) Now the broadcast function is not provided, therefore, 20, 30, 40, 50, 60, 70, 80 and 90 cannot be used.
Pin1
Pin1
Pin1
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 97
3) Only one data (1 Word/ 1 Double Word / 1 Bit) can be read and written for each communication. So, the
“Optimize” (Optimization for reading) selection in “Communication” tab in the “Configuration” dialog box
in “Options” menu (Options Æ Configuration Æ Communication) is cancelled.
4) When using RS-232 communication, the user only can use 3 pins (Pin 2, Pin 3 and Pin 5). DO NOT use
5 pins for RS-232 communication. Also, Pin 9 is for +5V. Do not confuse and connect to the wrong pin;
otherwise the serious damage may occur.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
1-98
Revision January 2008 Doc Name: 2007PDD23000007
Modbus(Master) --- 984 RTU / ASCII mode
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1. (ASCII)
9600, 8, EVEN, 1. (RTU)
Controller station number: 0.
Control area/status area: W40100 / W40200.
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Output Registers
Wn
n: 40001 ~ 50000
N/A
Word
Input Registers
Wn
n: 30001 ~ 40000
N/A
Word
¾ Input Registers is “read only”.
Contacts
Read/Write Range
Contact type
Format
Word No.
Bit No.
Discrete Outputs
Bn
N/A
n: 1 ~ 10000
Discrete Inputs
Bn
N/A
n: 10001 ~ 20000
¾ Discrete Inputs is “read only”.
C. Connections (Connector Pinouts)
Please refer to 1.1 Pin Definition of Serial Communication for detail.
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series
R
i i
J
2008 D
N
2007PDD23000007
1 99
Modbus Hexadecimal Address (Master) --- RTU / ASCII mode
Back to Table
A. HMI factory settings
Baud rate: 9600, 7, EVEN, 1. (ASCII)
9600, 8, EVEN, 1. (RTU)
Controller station number: 0.
Control area/status area: RW-0 / RW-10.
NOTE
1) The valid communication address starts from 0 and the format is hexadecimal. So the settable range are
0 to 65535 (i.e. 0 ~ FFFF in hexadecimal format).
2) The difference than “Standard Modbus” communication: (Protocol is the same)
The usage of setting communication address is different.
The range of communication address is different
The “Standard Modbus” communication is in decimal format. The start addresses are 40001, 30001, 1,
10001 and contains 10000 addresses respectively (40001 ~ 50000, 30001 ~ 40000, 1 ~ 10000, 10001 ~
20000).
The Modbus Hexadecimal Address (Master) is in hexadecimal format. The starting addresses are all
from 0 and there is 65536 addressing space (from 0 to FFFF) in each PDU (protocol data unit).
B. Definition of controller Read/Write address
Registers
Read/Write Range
Register Type
Format
Word No.
Bit No.
Data length
Output Registers
RW-n
n: 0 ~ FFFF
N/A
Word
Input Registers
R-n
n: 0 ~ FFFF
N/A
Word
¾ RW- : can Read and Write.
Converting the address to decimal format and plus 40001, it will immediately become the corresponding
“Standard Modbus” communication address.
¾ R- (Input Registers) : Read only.
Converting the address to decimal format and plus 30001, it will immediately become the corresponding
“Standard Modbus” communication address.