Aritech EV400-PLUS Series Quick Start Manual

Text of the manual

3.0 m max.

1.8 m min. 2.4 m nom. 2.5 m 7.5 m 16 m Fig. 2 EV400-PLUS SERIES PIR DETECTOR Aritech is an ISO 9001 certified manufacturer -1- Deutsch Español English Italiano Siting the detector (fig. 2). Install the detector so that the expected movement of an intruder will be across the fields of view. This is the direction best de

Programming the sensitivity.

Sensitivity is programmed according to the position of jumper J1. BI. BI-CURTAIN MODE: In this setting an extra level of processing is applied to provide enhanced stability in the presence of false alarm hazards in smaller areas. Not suitable for single curtain applications or a range less

"CV" = Control Voltage:

Either "Low" or "High" Control Voltage may be used. Select the appropriate Control Voltage setting. fig.4. "Low" = 0 Volt "High" = 12 Volt English EV430-PLUS SERIES ONLY. Alarm memory Note: First set the Control Voltage ("CV") by jumper J4 (fig. 3). (For example:

Selecting the Coverage Pattern.

Mask the appropriate mirror curtains with the adhesive labels provided and reassem- ble the sensor module. For example: see fig. 5 for mirror curtain coverage pattern corresp

crête è crête

Consommation Sans alarme Alarme Hauteur de montage Plage de vitesse de la cible Connexions d’alarme Temps en alarme Connexions antisabotage Plage de temperature Humidité relative Dimensions Poids Nombre de zones Angle de detection Plage de detection Technische gegevens: Aansluit