35PTHH Pulse shut-off nutsetter Instruction Manual P2122BA/EN 2014-06

2122a_ Deckblatt_en.fm, 03.07.2014

Notes on this instruction manual The original language of this instruction manual is German. This instruction manual • provides important instructions for safe and effective operation. • It describes the function and operation of the pulse shut-off nutsetter (hereafter referred to simply as 35PTHH). • It serves as a reference work for technical data, service intervals and spare part orders. • It points out options. Model Key Disclaimer: Apex Tool Group reserves the right to modify, supplement or improve the document or the product without prior announcement. This document may not be reproduced in any way, shape or form, in full or parts thereof, or copied to another natural or machine readable language or to a data carrier, whether electronic, mechanical, optical or otherwise without the express permission of Apex Tool Group. Secondary information P2204BA Instruction Manual Oil filling unit In the text 35PTHH stands for all of the designs of the pulse shut-off nutsetter described here.  identifies instructions to be followed. • identifies lists. <…> identifies an index, see 9 Spare parts, page 29. In graphics: identifies movement in a direction. identifies function and force. In graphic illustrations: If not absolutely essential, 35PTHH (air from bottom) is illustrated. 35 P T H H × ×× 3 Max. capacity Output drive 35 – 35 Nm 3 – External square 3/8" Q – Quick change chuck 1/4" Design Speed P – Pistol grip 40 – 4,000 rpm Shutoff 2. Air Inlet T – Torque controlled shut-off A – Air from top – None Pulse mechanism Design H – Hydraulics H

Warnings and notes..................................................................................................... 5

1.2 Basic requirements for safe working practices............................................................ 6 1.3 Operator training ......................................................................................................... 6 1.4 Personal protective equipment.................................................................................... 7 1.5 Designated use ........................................................................................................... 7 1.6 Noise and vibrations.................................................................................................... 7 2 Items supplied 8 3 Product description 8 3.1 Operation and functional elements.............................................................................. 8 3.2 Options........................................................................................................................ 9 4 Before initial operation 9 4.1 Air supply..................................................................................................................... 9 4.2 Change air inlet: top / bottom (only on 35PTHHA) .................................................... 10 4.3 Connect the tool ........................................................................................................ 10 4.4 Setting up the tool ..................................................................................................... 11 5 Troubleshooting 13 6 Maintenance 15 6.1 Service schedule....................................................................................................... 15 6.2 Fill reserve oil ............................................................................................................ 16 6.3 Complete oil filling ..................................................................................................... 18 7 Disassembly instructions 21 7.1 Remove motor unit.................................................................................................... 21 7.2 Remove throttle valve................................................................................................ 23 7.3 Remove pulse unit..................................................................................................... 24 8 Assembly instructions 24 8.1 Install motor unit........................................................................................................ 24 8.2 Install pulse unit......................................................................................................... 28 9 Spare parts 29 9.1 Pistol grip 35PTHH… ................................................................................................ 30 9.2 Pistol grip 35PTHHA….............................................................................................. 32 9.3 Motor unit .................................................................................................................. 34 9.4 Pulse unit................................................................................................................... 36 9.5 Equipment order list .................................................................................................. 38 10 Technical data 39 10.1 Dimensions 35PTHH… in mm .................................................................................. 39

Dimensions 35PTHHA… in mm ................................................................................ 40

10.3 Performance Data ..................................................................................................... 40 10.4 Ambient conditions .................................................................................................... 41 11 Service 41 12 Disposal 41

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06 5 Safety 1 1 Safety 1.1 Warnings and notes Warning notes are identified by a signal word and a pictogram: • The signal word describes the severity and the probability of the impending danger. • The pictogram describes the type of danger. WARNING! Potentially hazardous situation for health and safety. If this warning is not observed, death or serious injury may occur. CAUTION! Potentially hazardous situation to health and safety, or risk of material and environmental damage. If this warning is not observed, injuries or damage to materials or the environmental could occur. NOTE General notes include application tips and particularly useful information but no hazard warnings.

2123b_1_5_en_ bedingt.fm, 03.07.2014

Safety 1 1.2 Basic requirements for safe working practices All instructions must be read carefully. Failure to observe the instructions listed below can result in serious injuries. 1.3 Operator training Users must be given instruction in the correct usage of the tool. The operator must make the Operating Manual accessible to users and make sure that the users have read and understood it. The tool may only be connected, used, serviced and repaired by qualified persons. Repairs to the tool may only be performed by authorized personnel. CAUTION!  Work with a maximum working pressure of 700 kPa (measured at the air inlet tube of the tool).  Before initial operation, check that the suspension bail is properly fastened to the balancer.  35PTHHA: Before using the air inlet from above, make sure that the pipe plug is correctly fitted in the lower air inlet.  If you hear unusual noises or vibrations, switch off the tool immediately. Cut off the air supply immediately.  Before carrying out repairs, adjusting the torque or replacing screw bits, disconnect the tool from the compressed air line.  The compressed air line must be depressurized before disconnecting it.  Never use the air hose to hold, raise or lower the tool.  Air hoses, the suspension bail and fittings must be regularly checked for damage and wear. Renew as necessary.  Always carry out assembly according to Chapter 9 Spare parts, page 29.  Use only accessory parts authorized by Apex Tool Group (see product catalog).  Adjust the torque using the provided hex wrench only. Never use an angular wrench.  Only use screw bits for machine-controlled fastening tools.  Make sure that the screw bits are securely inserted.  Inspect screw bits for visible damage and cracks. Renew damaged bits immediately.  The operation, maintenance and repair conditions set forth in the instruction manual must be observed.  Follow generally valid and local safety and accident prevention rules.

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06 7 Safety 1 1.4 Personal protective equipment • Wear protective goggles to protect against sprays of metal splinters and fluids. • Wear gloves to protect against skin irritation in case of direct contact with oil. Danger of injury by being wound up in and caught by machinery • Wear a hairnet. • Wear close-fitting clothing. • Do not wear jewelry. Sound level in the area of the user > 80 dB(A), danger of hearing damage • Wear hearing protection. 1.5 Designated use The 35PTHH is designed exclusively for fastening and releasing threaded fasteners. • Do not use it as a hammer. • Do not open it or modify it structurally. • Do not use it in areas where there is a risk of explosion. 1.6 Noise and vibrations With vibration levels ahv > 2.5 m², the exposure time is to be reduced. See example Sound pressure level Lp in accordance with DIN EN ISO 15744 Idle / clockwise rotation for n  4,000 rpm < 76 dB(A) Vibration values in accordance with DIN EN ISO 28927-2 Idle / clockwise rotation ahv for n  4,000 rpm < 1.0 m/s² Pulses ahv 35PTHH < 3.0 m/s² Pulses ahv 35PTHHA < 3.5 m/s² Pulses ahv 35PTHHA + absorber (on request) < 2.5 m/s² Vibration level ahv m/s² Allowed daily exposure time (hrs.) Example Not allowed Allowed

2123b_1_5_en_ bedingt.fm, 03.07.2014

Items supplied 2 2 Items supplied Check shipment for transit damage and ensure that all items have been supplied: 1 35PTHH 1 This instruction manual 1 Declaration of Conformity 1 Hex wrench (WAF 2) 3 Product description 3.1 Operation and functional elements Item. Designation 1 Reverse switch 2 Torque adjustment, see Abb. 4-1 , page 11 3 Pulse count settings, see 4.4.2 Change pulse count, page 12 4 Air inlet 4 1 5 3 6 8 7 9 2 (8) Alternative position 2 5 4 35PTHH 35PTHHA…

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06 9 Before initial operation 4 3.2 Options 4 Before initial operation 4.1 Air supply  Make sure that the pressure before the pressure regulator is at least 0.5 bar higher than the required inlet air pressure at the tool.  Keep the inside of the air hose free of residue; clean it if necessary. Air quality In accordance with ISO 8573-1, quality class 2.4.3, compressed air must be dry and clean. Air preparation units Our recommendation: air preparation units (filters, regulators, lubricators) should be installed 5 Connection for evaluation electronics TVP100 6 Start button 7 Reserve oil adjustment, see 6.2 Fill reserve oil, page 16 8 Suspension bail 9 Hex wrench (WAF 2), order no. 935490 Order no. 934918 Signal connection kit for evaluation elec- tronics TVP100 Protective sleeve Order No. 937448PT – 35PTHH… Order No. 937443PT – 35PTHHA… Vibration absorber Order No. 935965 – 35PTHHA… Parameter Data Air hose Inner diameter 3/8" (ø 9.5 mm), maximum length 5 m Air inlet 1/4" NPT, inner diameter 7.5 mm Parameter Data Working pressure range 400 … 700 kPa Max. dew point + 10° C Device Explanation Filter Retention of particles > 15 micrometers. Removes more than 90% of condensation. Item. Designation

2123b_1_5_en_ bedingt.fm, 03.07.2014

Before initial operation 4 Oils according to DIN 51524 / ISO 3498 4.2 Change air inlet: top / bottom (only on 35PTHHA) When delivered, the air inlet is at the BOTTOM and sealed with a screw plug. To change the air supply from top to bottom:  Remove the air strainer from the air inlet at the TOP (do not discard), see 9.2 Pistol grip 35PTHHA…, page 32, Detail X.  Remove screw plug from BOTTOM. When doing this, counterhold with wrench (WAF 17).  Seal the air inlet at TOP with screw plug in accordance with specifications. 4.3 Connect the tool  Connect the tool to the compressed air line. Maximum screwing-in torque = 40 Nm. Reaction torque at flat end. Counterhold with wrench (WAF 17).  Activate compressed air: 620 kPa in anticlockwise rotation. Regulator To attain constant work results, the working pressure must be kept constant for every individual tool. Lubricator Compressed air requires a small amount of oil and is orientated to the air consumption of the tool.  Calculate the time (T) between two drops of oil and make the following settings at the lubricator: F = Factor for pulse shut-off nutsetter = 4 L = Air consumption of tool at idle m³/min (see performance data for pulse shut-off nutsetter) Order no. Packaging unit Liter Name ARAL BP elf ESSO INA Mobil Klüber SHELL 933090 2 HL32 Aralub EE 100 Energol HL 32 Polyelis 32 Olna 32 Nuto H 32 Hydraol 32A D.T.E.Oil Light Vactra Oil Light Crukolan 32 Molina 32 Molina 22 CAUTION! The air hose can come off by itself and whip around uncontrollably.  Shut off the compressed air before making the connection. Device Explanation T 60 F  L = -------------

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06 11 Before initial operation 4 4.3.1 Testing 4.4 Setting up the tool The tool must be configured for the desired rundown. 4.4.1 Setting the torque Abb. 4-1  Fully open exhaust air throttle anti- clockwise.  Check speed at output drive: Clockwise rotation 4,000 ±500 rpm Anticlockwise rotation 6,500 ±500 rpm. CAUTION! Danger of injury from unintended startup. Shut off the compressed air before adjusting the torque. CAUTION! Danger of injury from rotating hex wrench. Adjust the torque using the provided hex wrench only. Never use an angular wrench. Settings example: Tightening: 25 Nm Screw M8: 8.8  Approximately 3 turns of the torque adjustment screw Nm Torque Settings example: 25 Nm Turns of torque adjustment screw

2123b_1_5_en_ bedingt.fm, 03.07.2014

Before initial operation 4 Abb. 4-2 4.4.2 Change pulse count Abb. 4-3 1. Hold the output drive firmly. 2. Carefully push the hex wrench (WAF 2) through the hole of the pistol grip housing until it reaches the torque adjustment screw . 3. Turn the torque adjustment screw and roughly set the required torque, see Abb. 4-1 , page 116. Total number of turns = 6. 4. Remove hex wrench. The hole will automatically close after starting. 5. Carry out the rundown. 6. Check the shutoff mechanism worked properly, see 4.4.3 Measuring the torque, page 13. 7. In case of deviations, correct the torque setting and 8. Repeat the rundown. Requirement Measure High shut-off accuracy – especially with hard screwed joints. Increase number of pulses per tighten- ing. Recommended number of pulses  6. Reduce the speed. 1. Unscrew the threaded pin using the hex wrench (WAF 2). 2. Turn exhaust air throttle clock- wise. Shortening the rundown time, particu- larly for soft joints. Increase the speed. 1. Unscrew the threaded pin using the hex wrench (WAF 2). 2. Turn exhaust air throttle anticlock- wise. NOTE A pulse count change may be carried out while the compressed air is activated. After changing the pulse count, check the screwed torque and correct the setting as necessary, see Abb. 4-2 , page 12. Torque Speed

2123b_1_5_en_ bedingt.fm, 03.07.2014

P2122BA/EN 2014-06 13 Troubleshooting 5 4.4.3 Measuring the torque We recommend carrying out a static torque measurement by retightening the screwed joint. When carrying out a dynamic measurement using a transducer adapter, also carry out a static test on the screwed joint, for example with a torque wrench (electronic). 5 Troubleshooting Error Possible causes Measures and remedies Tool does not switch off Torque set too high  Reduce the torque setting, see Abb. 4-1 , page 11 Pulse count set too low  Increase pulse count, see 4.4.2 Change pulse count, page 12 Working pressure < 400 kPa  Check the cross section of the hose and coupling: Inner diameter 3/8" (ø 9.5 mm), maxi- mum length 5 m  Increase the working pressure. Reverse button is not at the detent  Turn the reverse button to the detent Excessive transmission damping due to extension and worn socket.  Use a shorter or more rigid exten- sion.  Replace the socket Insufficient oil in the pulse unit (no pulse build-up)  See 6.2 Fill reserve oil, page 16  If X = 0 (see picture 2), the reserve oil is exhausted and must be refilled to guarantee a controlled process., page 16 Screen in the air inlet tube / muffler is dirty  Clean or replace parts Insufficient shut-off accuracy Pulse count too low: <6  Increase pulse count, pulse count > 6 Adapter parts  Replace adapter parts  Use extension and socket with guide diameter Pressure fluctuations in the air network  Use a pressure regulator Fastening time too long: > 4 seconds Joint too soft; crush nuts, self-tapping screws  Use a pulse nutsetter with higher capacity. Use next tool size.  Use a mechanical screwdriver

Regular service reduces operating faults, repair costs and downtime.

This maintenance schedule uses values that are valid for most applications. For a specific maintenance interval, see 6.1.1 Calculating a customer-specific maintenance plan, page 16. Implement a safety-related maintenance program that takes the local regulations for repair and mainte- nance for all operating phases of the tool into account. CAUTION! Danger of injury due to unintentional activation – before service, disconnect the tool from the compressed air supply. Maintenance interval Rundowns Measures W1 100.000  Check the suspension bail for functional safety.  Check the air hose for wear.  Check the square on the output drive for wear.  Check the air inlet for tight fit.  Check the housing of the pulse unit for tight fit.  Check the maximum idling speed.  Check the reserve oil. W2 500.000  Oil change, see 6.3 Complete oil filling, page 18.  Motor service kit, see 3) Part of motor service kit K1, order no. 936252PT, page 31.  Hydraulic service kit, see 3) Part of hydraulic service kit K2, order no. 936211, page 37.  Replace muffler, filter. W3 1,000,000 Check individual parts and replace if necessary  Suspension bail  Throttle valve  Exhaust air throttle  Motor  Pulse unit

Calculating a customer-specific maintenance plan

A service interval W(1,2,3) depends on the following factors: T2, S and VS are variable factors and can differ depending on the specific application. Example for service interval W2: After 500,000 rundowns (V), a specific rundown time of 1.8 seconds (T1) with an actual fastening time of 3 seconds (soft joint) and 3 completed shifts per day and 750 rundowns per shift: You have to carry out the maintenance measures marked W2 after an operating time of 200 days. 6.2 Fill reserve oil If X = 0 (see picture 2), the reserve oil is exhausted and must be refilled to guarantee a controlled process. Factor Value assumed in 6.1, "Maintenance plan" Description V V1 = 100,000 V2 = 500,000 V3 = 1,000,000 Number of rundowns after which a maintenance measure is pre- scribed by Apex Tool Group. T1 1.8 seconds Specific rundown time, measured in life and endurance tests. T2 2 seconds Actual rundown time, depending on the hardness of the joint. S 1; 2; 3 Number of shifts per day. VS 750 Number of rundowns per shift. 1  Remove pulse unit. 2  Remove set bolt and ball. W 1 2 3     V  T1 T2  S  VS = ------------------------------ W2 500000 1 8   2  3  750 = --------------------------------- 200Tage = <103> <102> X = 0

 Align both ends as shown in the picture (internal equalization hole is opened).

4  To avoid air pockets, fill the filling hole full of oil. 5  Position the injector so that it has a sealing effect and add reserve oil until distance X for spacer is present.  Maintain distance X and secure with .  Refit set bolt and ball.  Remove . Approx. 5 ml X approx. 2.5 mm

Complete oil filling

If no more pulses are generated, or if the pulse unit has been removed and refitted, the pulse unit must be completely refilled with oil: Oil order No. 925715, ESSO-UNIVIS HVI26, approx. 2 liters, temperature 20 ±5 °C 1  Remove set bolt and ball 2  Align both ends of the pulse unit as shown in the picture (internal equalization hole is opened) 3  Use adapter to connect pulse unit to the quick disconnect coupling.  Close shutoff valve . 4  Set the working pressure to approx. 500 kPa.  Slowly open the shut-off valve all the way until the gauge shows a negative pressure of <10 mbar (-1 bar).  Wait approx. 2 minutes until the number of vac- uum bubbles has reduced significantly.  Slowly close the shut-off valve. The gauge shows atmospheric pressure again. Missing oil will be pressed back into the pulse unit.  If necessary, repeat the last 3 rundown steps until bubbles are reduced practically to zero. <103> <102>

Uncouple the pulse unit and unscrew the

adapter.  To avoid air pockets, fill the filling hole full of oil. 6  Position the injector so that it has a sealing effect and add reserve oil until distance X for spacer is achieved.  Maintain distance X and secure with .  Refit set bolt and ball.  Remove . • Small air bubbles that become visible due to the high pressure during filling do not mean that the pulse unit is leaking. The filling process is not impaired. • If a flow of large rapid bubbles appear and continue to be produced and the pressure drops, there is a leak inside of the pulse unit. Approx. 5 ml X approx. 2.5 mm

Disassembly instructions 7

7 Disassembly instructions <…> Please refer to 9 Spare parts, page 29 und 9.5 Equipment order list, page 38 7.1 Remove motor unit 7.1.1 Remove actuating ring 1 2 1 2 3 4

22 P2122BA/EN 2014-06 2123d_Reparatur_en_bedingt.fm, 03.07.2014 Disassembly instructions 7 7.1.2 Remove shut-off 1 2 3 4 5 6

Disassembly instructions 7

7.2 Remove throttle valve Changing blades Changing bearings / rotor 1 2 Spring force! 3 <61> <59> <56> <55> <60> <59> <54> <55> SW 3/8"

Remove pulse unit

Abb. 7-1 8 Assembly instructions <…> Please refer to 9 Spare parts, page 29 und 9.5 Equipment order list, page 38 8.1 Install motor unit CAUTION! Skin irritation in case of direct contact with oil. Wear protective gloves. CAUTION! Hydraulic blade is under spring pressure! Wear protective goggles. NOTE Permitted only if filling is guaranteed with oil filling device, see 6.2 Fill reserve oil, page 16. Pulse unit must have cooled down to room temperature. CAUTION! • Only perform installation in accordance with exploded drawing, see 9 Spare parts, page 29. Incorrect installation can lead to uncontrolled reactions, e.g. unexpected start-up or parts being hurled out. • Tighten all screwed joints of the tool carefully, according to the specifications. NOTE To prevent damage, lubricate the gaskets and O-rings using grease (order no. 914392) before assembly. WAF 1/2" <84>

Assembly instructions 8

8.1.1 Install rotor cover 1. Press <59> in with , see X. 2. Examine Y with thickness gage. If dimension > Y, step 1 with support , , repeat. Press <61> in with . <59> X <54> <55> X Base 0.02 0.03 0.04 0.05 Thickness gauge = 0.03 mm max. 2 mm Y <61> <56> <60>

26 P2122BA/EN 2014-06 2123d_Reparatur_en_bedingt.fm, 03.07.2014 Assembly instructions 8 8.1.2 Install shut-off 1 2 3 4 5 6 7 8

Assembly instructions 8

8.1.3 Install actuating ring 1 2 3 4 5 6

Install pulse unit

8.2.1 Assembling the hydraulic blades NOTE To prevent damage, lubricate the gaskets and O-rings using grease (order no. 914392) before assembly. 1 2 3 4 5 6 7 8 <93> <98> <93> <97> <95> <94> (2×) <97> <96> (2×) <93> <91> Tightening torque 60+10 Nm WAF 1/2" <84>

Spare parts 9

9 Spare parts NOTE Only Cleco original spare parts should ever be used. Using other parts could lead to inferior performance and increased maintenance requirements. If non-original spare parts are installed, the tool manufacturer is entitled to declare all warranty obligations for null and void. We would be glad to prepare a special quote for you for spare and wear parts. Please give the following data: • Tool model • Number of tools • Number of rundowns per day or per shift • Shut-off torque • Fastening time per rundown

Pistol grip 35PTHH…

Adhesive, order no. 914860 Grease, order no. 914392

Spare parts 9

1)Order no. 2)Quantity 3) Part of motor service kit K1, order no. 936252PT 4)Dimensions

Pistol grip 35PTHHA…

Adhesive, order no. 914860 Grease, order no. 914392

Spare parts 9

1)Order no. 2)Quantity 3) Part of motor service kit K1, order no. 936252PT 4)Dimensions

See 8.1.1 Install rotor cover, page 25

See 8.1.2 Install shut-off, page 26

Spare parts 9

1)Order no. 2)Quantity 3) Part of motor service kit K1, order no. 936252PT 4)Dimensions

see 8.2 Install pulse unit, page 28

For disassembly, note the position of the balls in the control disc. Reassemble balls in the same position.

Spare parts 9

1)Order no. 2)Quantity 3) Part of hydraulic service kit K2, order no. 936211 4)Dimensions *) see table on page 37 * Order no. <84> <93> <115> <116> <117> <118> <119> <120> 35PTHH403 35PTHHA403 3/8" 936043 935410 – – – – – – 35PTHH40Q 35PTHHA40Q 1/4" 936044 935453 931789 917794 935477 935406 931793 931789

Equipment order list

1)Order no.

Technical data 10

10 Technical data 10.1 Dimensions 35PTHH… in mm Abb. 10-1

Dimensions 35PTHHA… in mm

10.3 Performance Data Order no. Recommended torque range Idling speed Air consumption Ft-lbs. (Nm) 8.8 lbs. (kg) ft3/min (m3/min) min. max. rpm mm Idling Pulses 35PTHH403 35PTHHA403 3/8" 14.8 (20) 25.8 (35) Anticlockwise 6,500 Clockwise 4,000 M8 2.31 (1.05) 2.45 (1.11) 5.30 (0.15) 15.89 0.45 35PTHH40Q 35PTHHA40Q 1/4" 2.31 (1.05) 2.45 (1.11)

In the event of repairs, send the complete 35PTHH to Apex Tool Group! Repairs may only be carried out by

authorized personnel. Opening the tool will invalidate the warranty. 12 Disposal Storage temperature -25…+60 °C Working temperature +5…+40 °C Permissible relative humidity 25…90%, non-condensing CAUTION! Injuries and environmental damage from improper disposal. The components and auxiliary materials of a machine incorporate risks to health and the environment.  Catch auxiliary materials (oils, greases) when drained and dispose of them properly.  Separate the machine parts by material and dispose of them properly.  Separate the components of the packing and dispose of them by segregating them clearly.  Wear suitable protective clothing at the time of disposal.  Follow the general prevailing disposal guidelines.  Follow the locally applicable regulations.

0219 | Cleco® is a registered trademark of Apex Brands, Inc. | © 2019

Apex Tool Group, LLC Phone: +1 (800) 845-5629 Phone: +1 (919) 387-0099 Fax: +1 (803) 358-7681 www.ClecoTools.com www.ClecoTools.de POWER TOOLS SALES & SERVICE CENTERS Please note that all locations may not service all products. Contact the nearest Cleco® Sales & Service Center for the appropriate facility to handle your service requirements. Sales Center Service Center NORTH AMERICA | SOUTH AMERICA DETROIT, MICHIGAN Apex Tool Group 2630 Superior Court Auburn Hills, MI 48236 Phone: +1 (248) 393-5644 Fax: +1 (248) 391-6295 LEXINGTON, SOUTH CAROLINA Apex Tool Group 670 Industrial Drive Lexington, SC 29072 Phone: +1 (800) 845-5629 Phone: +1 (919) 387-0099 Fax: +1 (803) 358-7681 MEXICO Apex Tool Group Vialidad El Pueblito #103 Parque Industrial Querétaro Querétaro, QRO 76220 Mexico Phone: +52 (442) 211 3800 Fax: +52 (800) 685 5560 BRAZIL Apex Tool Group Av. Liberdade, 4055 Zona Industrial Iporanga Sorocaba, São Paulo CEP# 18087-170 Brazil Phone: +55 15 3238 3870 Fax: +55 15 3238 3938 EUROPE | MIDDLE EAST | AFRICA ENGLAND Apex Tool Group GmbH C/O Spline Gauges Piccadilly, Tamworth Staffordshire B78 2ER United Kingdom Phone: +44 1827 8727 71 Fax: +44 1827 8741 28 GERMANY Apex Tool Group GmbH Industriestraße 1 73463 Westhausen Germany Phone: +49 (0) 73 63 81 0 Fax: +49 (0) 73 63 81 222 HUNGARY Apex Tool Group Hungária Kft. Platánfa u. 2 9027 Györ Hungary Phone: +36 96 66 1383 Fax: +36 96 66 1135 ASIA PACIFIC AUSTRALIA Apex Tool Group 519 Nurigong Street, Albury NSW 2640 Australia Phone: +61 2 6058 0300 CHINA Apex Power Tool Trading (Shanghai) Co., Ltd. 2nd Floor, Area C 177 Bi Bo Road Pu Dong New Area, Shanghai China 201203 P.R.C. Phone: +86 21 60880320 Fax: +86 21 60880298 INDIA Apex Power Tool India Private Limited Gala No. 1, Plot No. 5 S. No. 234, 235 & 245 Indialand Global Industrial Park Taluka-Mulsi, Phase I Hinjawadi, Pune 411057 Maharashtra, India Phone: +91 020 66761111 JAPAN Apex Tool Group Japan Korin-Kaikan 5F, 3-6-23 Shibakoen, Minato- Ku, Tokyo 105-0011, JAPAN Phone: +81-3-6450-1840 Fax: +81-3-6450-1841 KOREA Apex Tool Group Korea #1503, Hibrand Living Bldg., 215 Yangjae-dong, Seocho-gu, Seoul 137-924, Korea Phone: +82-2-2155-0250 Fax: +82-2-2155-0252