DORANI C10 Quick Apartment Setup Manual

Specifications

Brand: DORANI
Category: Intercom System
Model: C10 (Quick Apartment Setup Manual)
File Type: PDF
File Size: —
Pages: 12

Read Online

Read the DORANI C10 Quick Apartment Setup Manual online using the built-in PDF viewer.

Text of the manual

IP APARTMENT VIDEO INTERCOM

QUICK APARTMENT SETUP GUIDE WW.DORANI.COM.AU Dorani (PJM Sales) – 03 9357 0942 4/1 Merri Concourse, Campbellfield, Victoria 3061

KNOW YOUR MONITOR

Monitor Menu Monitoring of Door Stations Call Record Menu Reviewing of picture Memory Intercom Menu Calling Other Monitors in System Identifies Door Station Number Calling Settings – Volume, Brightness, Contrast Snapshot – Takes a Snapshot Image of Screen Unlock Lock 1 or Lock 2 Talk – Starts the communication to the door station Info Settings Menu All Installer Setting Lock Release Shortcut Menu Unlock Lock 1 Back Button Exit Off

10 BASE T / 100 BASE TX Ethernet RJ45

Screen 7” Digital Color TFT Resolution 800 x 480 Dimensions (W,H,D) 174 x 161 x 22 Apartment Door Station Model Surface: DORVIP01 Model Flush: DORVIP02 Voltage POE 48V Current Draw 100mA LAN Interface 10 BASE T / 100 BASE TX Ethernet RJ45 Lens Angle 170 Degree Fish Eye Screen 5” Color TFT Resolution 800 x 480 IP Rating IP65 Surface Mount Flush Mount Dimensions (W,H,D) 110 x 281 x 44 133 x 316 x 2 Lock Release Optional: Relay NO/C Relay NC/C 12VDC 350mA Out Single Door Station Model Surface: DORVIP03 Voltage POE 48V Current Draw 100mA LAN Interface 10 BASE T / 100 BASE TX Ethernet RJ45 Lens Angle 170 Degree Fish Eye Resolution 800 x 480 IP Rating IP65 Dimensions (W,H,D) 60 x 160 x 30 Cabling Standard TCP/IP Network Cabling Cat5/Cat 6 to be used. Cat 5/Cat 6 Maximum 90m When Exceeding these disttances it is recommended that Fibre Optic and Network configuration be designed to accomodate

The Dorani IP Intercom system is very simple to install using standard network topology and POE 48V

switches to distribute the network. Systems up to 80 Devices

EB+ = Exit Button NO

EB- = Exit Button C NO = Relay COM(LK+) = Relay LK - = Negative +12V = 12VDC Poisitive 350mA Relay TYPE must be set in Door Station Settings The Lock release Time, and Normally Open/Normally Closed settings can be adjusted ALL CABLES SHOULD BE TESTED BEFORE CONNECTING AND POWERING UP OF THE SYSTEM Once all the cables are terminated, tested and connected, powering up of the system can take place. Programming of the Monitors and the Door Stations can then be completed following the next procedure EB+ EB- COM(LK+) NO LK- +12V EB+ EB- NO COM(LK+) LK- +12V It is recommended to use a separate transformer and the Relay Ouput Connections Relay connections MUST be used for the following: Fail Safe Locks Magnetic Locks Gate Motors/Door Controllers Locks Greater that 12V DC or 350Ma Standard 568A Connection Pin 1 - Green Pin 2 - Green/White Pin 3 – Orange/White Pin 4 – Blue Pin 5 – Blue/White Pin 6 – Orange Pin 7 – Brown/White Pin 8 – Brown Relay output 12v Lock Release COM 2 NO 2 Relay output 2 Relay 2 for second lock release NO2 = Relay 2 COM2 = Relay 2 **Relay 2 MUST have separate 12v supply for latching**

PROGRAMMING APARTMENT MONITORS

TCP/IP – DHCP & STATIC The system has an inbuilt DHCP allocation, so the monitors will be given their own IP address on initialization. Setting Unit Config /Call Number Enter Settings Menu Enter Installer Menu Password: 66666666 (8x6) Unit Config Allows for changes to unit configuration (SB) 434 Example: This is unit 434 Press Unit Config to change IP Config If you wish to create a Static Network and assign individual IP addresses to the system this can be done in the IP Config Settings. More details on this are available in the extended install guide.

YOU CAN GO BACK INTO THE UNIT CONFIG PAGE TO CONFIRM SETTINGS HAVE BEEN PROGRAMMED

BASIC PROGRAMMING OF THE MONITOR IS NOW COMPLETE IF YOU CALL THE UNIT NUMBER FROM THE DOOR STATION THIS UNIT WILL NOW RING Call_Nbr Device_Addr = (Install Type) Unit Number Mast_Slave = Master or Slave configuration, 1 Master per unit, remainder are slaves Name = Monitor Model (Can be changed to Unit number) Unit # MB = In Multi Building Separate Call Number Generally NOT used (See extended install guide) Unit # SB = In Single Building Separate Call Number Generally NOT used (See extended install guide) MB = Multi Building Apartment (8 digit calling) If calling digits exceed 4 numbers or buildings are identified separately Press Device Address to edit unit number calling Select Building Type (SH) Single Home Install with single door station Select this ONLY if using Single Button Door Station in a single home installation (SB) Single Building Apartment Generally Used for ALL Apartment installs Other Settings generally not used (See extended install guide) Input Unit Number 4 Digits 0001 0011 0101 1101 When calling 2 or 3 digits can be used, 4 digits only used for programming purposes and identification of the units. Press OK

MULTI MONITOR SYSTEMS

2+ Monitors per Room PROGRAMMING APARTMENT DOOR STATIONS Call_Nbr If you have more than 1 monitor installer per Apartment or in a Single Home installation only 1 Master monitor can be assigned. The remainder must be assigned as Slave monitors Press Mast_Slave and assign monitors as below 01 = Master 02 = Slave 1 03 – Slave 2 Maximum of 9 Slaves per unit Enter Programming Press Residents Unlock Input Password: 990166666666 9901(8 x6) Options Select Always in Installer Mode for extended programming Unselect Always in program mode for short term programming NOTE: ALWAYS remember to exit programming mode

Numbering Door Stations

Each Door Station should have a Different Number Once you have entered installer mode you can always access the menu items Tap Top Section to enter installation menu Click Settings Menu Click Call Nbr Change Door Number Change Door Station ID Change Door Station Name if Desired

Changing Locking Parameters

Click Settings Menu Click Parameter Click Lock and PWD Page 1 Managers Password = Installer Password Common Unlock Code = 4 Digit Code for Door Unlock Code Unlock Enable 1 = ON 0 = OFF Remote Unlock Code = NOT USED Page 2 Code Error Protection = NOT USED Lock 1 Mode = Normally Open Normally Closed Lock 1 Unlock Timing Time = Length of Time relay operates

All Dorani Video Intercom products come with a limited 12 month warranty from time of initial

purchase. This warranty is covered by Dorani Pty Ltd standard terms and conditions. Diversion and Mobile device connection warranty and disclaimer is outlined in detail at www.dorani.com.au. Please read all terms and conditions and disclaimers and if you have any queries, please contact your installer or Dorani Pty Ltd directly in relation to these. For any service, technical support or warranty items please contact your original installer or local representative for assistance. Technical Support: [email protected] WWW.DORANI.COM.AU [email protected] Dorani (PJM Sales) – 03 9357 0942 4/1 Merri Concourse, Campbellfield, Victoria 3061