DRAKE 1002613B Instruction Manual
Read Online
Read the DRAKE 1002613B Instruction Manual online using the built-in PDF viewer.
Text of the manual
Rev: 072920 / 651243000C-1
© 2018 R.L. Drake Holdings, LLC.
800-523-6049
www.rldrake.com
PEG PLUS Model
Public Educational & Governmental Access Encoder
INSTRUCTION MANUAL
Model
Item #
Description
PEG PLUS
1002613B
HD PEG Channel Encoder with HD-SDI Input or Composite
Video with Left + Right Audio and IP Output
800-523-6049 | www.rldrake.com
We recommend that you write the following information in the spaces provided below.
This product incorporates copyright protection technology that is protected by U.S. patents and other intellectual property
rights. Reverse engineering or disassembly is prohibited.
Manual Revision
Issue 2: User Manual updated for use with firmware v1.5.9 - v1.5.24 (current as of 06/07/18).
Issue 1: User Manual created 01/31/17. Firmware release v1.5.9.
Product Documentation:
Download the latest User Manual (PDF) by visiting our website. Navigate to the product page by entering the
full Model Name or Stock Number in the search field. Upon reaching the product page, the "User Manual" and
other downloads are made available beneath the product image.
Cross-Reference & Hyperlinking Usage:
This guide makes use of hyperlinks for the Table of Contents, some cross-reference linking between sections,
and external hyperlinking to web addresses. This has been done to assist the reader in finding the information
they are seeking in a much quicker way. In addition to hyperlinking, the Table of Contents also makes use of
the bookmarking feature present in the Adobe Reader application.
Firmware Updates:
For more information regarding the latest product firmware releases, please visit our website at www.rldrake.
com. The Firmware Updates page is available under the "Support" menu option within the main navigation.
General instructions for the FTP site, as well as updating your firmware, are provided on this page. For further
assistance, you may also contact Technical Assistance at 937-746-6990 or by email: servicehelp@rldrake.
com
Purchase Location Name:
Purchase Location Telephone Number:
PEG PLUS Serial Number
800-523-6049 | www.rldrake.com
Table of Contents
GENERAL & SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS ................................................................................................................................ 4
SPECIFICATIONS ................................................................................................................................................................... 6
GENERAL DESCRIPTION & FEATURES ............................................................................................................................. 7
FRONT AND REAR PANEL OPERATION............................................................................................................................. 8
INSTALLATION & SETUP
INSTALLATION & POWER-UP .............................................................................................................................................. 9
LOGIN SCREEN .................................................................................................................................................................... 10
UNIT CONFIGURATION
STATUS TAB ...........................................................................................................................................................................11
STATUS TAB WITH ZIXI ....................................................................................................................................................... 12
ENCODER TAB ..................................................................................................................................................................... 12
AV INPUT .............................................................................................................................................................................................12
ENCODING ...........................................................................................................................................................................................13
ENCODING (ZIXI) ................................................................................................................................................................................19
COMPOSITING ....................................................................................................................................................................................21
SYSTEM TAB ......................................................................................................................................................................... 22
NETWORKING .....................................................................................................................................................................................22
REMOTE MANAGEMENT ...................................................................................................................................................................24
SAVE/RESTORE ..................................................................................................................................................................................24
SET SYSTEM TIME .............................................................................................................................................................................25
LOG TAB ................................................................................................................................................................................ 26
ADMINISTRATION PANEL
ADMIN PANEL ....................................................................................................................................................................... 26
FIRMWARE UPDATES
FIRMWARE UPDATE TAB .................................................................................................................................................... 28
SERVICE & WARRANTY
SERVICE ................................................................................................................................................................................ 30
LIMITED WARRANTY ........................................................................................................................................................... 31
800-523-6049 | www.rldrake.com
Important Safety Instructions
1. Read Instructions—All the safety and operating instructions should be read before the
product is operated.
2. Retain Instructions—The safety and operating instructions should be retained for future
reference.
3. Heed Warnings—All warnings on the product and in the operating instructions should be
adhered to.
4. Follow Instructions—All operating and use instructions should be followed.
5. Cleaning—Unplug this product from the wall outlet before cleaning. Do not use liquid
cleaners or aerosol cleansers. Use a damp cloth for cleaning.
6. Attachments—Do not use attachments that are not recommended by the product manu-
facturer as they may cause hazards.
7. Water and Moisture—Do not use this product near water—for example, near a bathtub,
wash bowl, kitchen sink or laundry tub; in a wet basement; or near a swimming pool; and
the like.
8. Accessories—Do not place this product on an unstable cart, stand, tripod, bracket, or
table. The product may fall, causing serious injury to a child or adult, and serious damage
to the product. Use only with a cart, stand, tripod, bracket, or table recommended by the
manufacturer, or sold with the product. Any mounting of the product should follow the
manufacturer’s instructions, and should use a mounting accessory recommended by the
manufacturer.
9. A product and cart combination should be moved with care. Quick stops, excessive force,
and uneven surfaces may cause the product and cart combination to overturn.
10. Ventilation—Slots and openings in the cabinet are provided for ventilation and to ensure
reliable operation of the product and to protect it from overheating, and these openings
must not be blocked or covered. The openings should never be blocked by placing the
product on a bed, sofa, rug, or similar surface. This product should not be placed in a built-in
installation such as bookcase or rack unless proper ventilation is provided or the manufac-
turer’s instructions have been adhered to.
11. Power Sources—This product should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of power supplied to your
home, consult your product dealer or local power company. For products intended to oper-
ate from battery power, or other sources, refer to the operating instructions.
12. Grounding or Polarization—This product may be equipped with a polarized alternat-
ingcurrent line plug (a plug having one blade wider than the other). This plug will fit into
the power outlet only one way. This is a safety feature. If you are unable to insert the plug
fully into the outlet, try reversing the plug. If the plug should still fail to fit, contact your
electrician to replace your obsolete outlet. Do not defeat the safety purpose of the polarized
plug. Alternate Warnings—If this product is equipped with a three-wire grounding-type
plug, a plug having a third (grounding) pin, the plug will only fit into a grounding-type power
outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact
your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the
grounding-type plug.
13. Power-Cord Protection—Power-supply cords should be routed so that they are not
likely to be walked on or pinched by items placed upon or against them, paying particular
attention to cords at plugs, convenience receptacles, and the point where they exit from the
product.
14. Outdoor Antenna Grounding—If an outside antenna or cable system is connected to the
product, be sure the antenna or cable system is grounded so as to provide some protection
against voltage surges and built-up static charges. Article 810 of the National Electrical Code,
ANSI/NFPA 70, provides information with regard to proper grounding of the mast and sup-
porting structure, grounding of the lead-in wire to an antenna discharge unit, size of ground-
ing conductors, location of antenna-discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode. See Figure A.
15. Lightning—For added protection for this product during a lightning storm, or when it
is left unattended and unused for long periods of time, unplug it from the wall outlet and
disconnect the antenna or cable system. This will prevent damage to the product due to
lightning and power-line surges.
16. Power Lines—An outside antenna system should not be located in the vicinity of over-
head power lines, other electric light or power circuits, where it can fall into such power lines
or circuits.
17. Overloading—Do not overload wall outlets, extension cords, or integral convenience
receptacles as this can result in a risk of fire or electric shock.
18. Object and Liquid Entry—Never push objects of any kind into this product through open-
ings as they may touch dangerous voltage points or short-out parts that could result in a fire
or electric shock. Never spill liquid of any kind on the product.
19. Servicing—Do not attempt to service this product yourself as opening or removing cov-
ers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified
service personnel.
20. Damage Requiring Service—Unplug this product from the wall outlet and refer servicing
to qualified service personnel under the following conditions:
a. When the power-supply cord or plug is damaged,
b. If liquid has been spilled, or objects have fallen into the product,
c. If the product has been exposed to rain or water,
d. If the product does not operate normally by following the operating instructions. Adjust
only those controls that are covered by the operating instructions as an improper adjust-
ment of other controls may result in damage and will often require extensive work by a
qualified technician to restore the product to its normal operation,
e. If the product has been dropped or damaged in any way, and
f. When the product exhibits a distinct change in performance—this indicates a need for
service.
21. Replacement Parts—When replacement parts are required, be sure the service techni-
cian has used replacement parts specified by the manufacturer or have the same characteris-
tics as the original part. Unauthorized substitutes may result in fire, electric shock or other
hazards.
22. Safety Check—Upon completion of any service or repairs to this product, ask the service
technician to perform safety checks to determine that the product is in proper operating
condition.
23. Wall or Ceiling Mounting—The product should be mounted to a wall or ceiling only as
recommended by the manufacturer.
24. Heat—The product should be situated away from heat sources such as radiators, heat
registers, stoves, or other products (including amplifiers) that produce heat.
NOTE TO CATV SYSTEM INSTALLERS:
THIS REMINDER IS PROVIDED TO CALL THE CATV
SYSTEM INSTALLER’S ATTENTION TO ARTICLE 820 - 40
OF THE NEC WHICH PROVIDES GUIDELINES FOR PROPER
GROUNDING AND, IN PARTICULAR, SPECIFIES THAT
THE CABLE GROUND SHALL BE CONNECTED TO THE
GROUNDING SYSTEM OF THE BUILDING, AS CLOSE TO
THE POINT OF CABLE ENTRY AS PRACTICAL.
FIGURE A
Example of antenna grounding as per National Electrical Code, ANSI/NFPA 70
ANTENNA
LEAD IN
WIRE
ANTENNA
DISCHARGE UNIT
(NEC SECTION 810-20)
GROUNDING
CONDUCTORS
(NEC SECTION 810-21)
POWER SERVICE GROUNDING ELECTRODE
SYSTEM (NEC ART 250, PART H)
ELECTRIC
SERVICE
EQUIPMENT
GROUND CLAMPS
GROUND CLAMP
NEC - NATIONAL ELECTRIC CODE
WARNING: TO PREVENT FIRE OR
ELECTRICAL SHOCK DO NOT
EXPOSE TO RAIN OR MOISTURE
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT
REMOVE POWER SUPPLY COVERS
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
! CAUTION !
CAUTION STATEMENT
An appliance and cart combination should be moved with care. Quick stops, excessive
force and uneven surfaces may cause the appliance and cart combination to overturn.
The exclamation point within an equilateral triangle is intended to alert the user to
the presence of important operating and maintenance (servicing) instructions in the
literature accompanying the appliance.
The lightning flash with arrow head symbol, within an equilateral triangle, is intended to
alert the user to the presence of uninsulated “dangerous voltage” within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE. DO NOT OPEN THE CABINET, REFER
SERVICING TO QUALIFIED PERSONNEL ONLY.
CAUTION: TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS (POLARIZED) PLUG WITH AN
EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN
BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
800-523-6049 | www.rldrake.com
Importantes De Sécurité
1. Lire les directives—Toutes les directives de sécurité et d’utilisation devraient être lues
avant de mettre l’appareil en opération.
2. Conserver les directives—Les directives de sécurité et d’utilisation devraient être con-
servées pour consultation future.
3. Tenir compte des avertissements—Tous les avertissements apparaissant sur l’appareil et
dans les consignes d’utilisation devraient être respectés.
4. Suivre les directives—Toutes les directives d’opération et d’utilisation devraient être
suivies.
5. Nettoyage—Débrancher l’appareil de la prise électrique murale avant le nettoyage. Ne pas
utiliser de nettoyants liquides ou aérosols. Employer un linge humide pour le nettoyage.
6. Fixation—Ne pas utiliser d’autres fixations que celles recommandées par le manufacturier;
elles pourraient être source de dangers.
7. Eau et humidité—Ne pas utiliser cet appareil près de l’eau. Par exemple, près d’une
baignoire, d’un bac de lavage, d’un évier de cuisine ou d’une cuvette de lessivage; dans un
sous-sol humide; ou à proximité d’une piscine; et autres environnements similaires.
8. Accessoires—Ne pas installer cet appareil sur un chariot, un socle, un trépied, un support
ou une table instables. L’appareil pourrait tomber, entraînant des blessures graves à un
enfant ou à un adulte, et des dommages importants à l’appareil. Employer seulement avec
un chariot, un socle, un trépied, un support, ou une table recommandés par le fabricant ou
vendu avec l’appareil. Toute installation de l’appareil devrait être conforme aux directives du
manufacturier et devrait utiliser des accessoires d’installation recommandés par celui-ci.
9. Un chariot supportant l’appareil devrait être déplacé avec précaution. Les arrêts brusques,
la force excessive et les surfaces inégales peuvent renverser le chariot.
10. Ventilation—Des fentes et ouvertures dans le châssis sont prévues pour la ventilation
de l’appareil, pour en assurer la fiabilité d’opération et le protéger contre la surchauffe.
Ces ouvertures ne doivent pas être bloquées ou recouvertes. Ces ouvertures ne devraient
jamais être bloquées en plaçant l’appareil sur un lit, un sofa, une couverture, ou une surface
semblable. Cet appareil ne devrait pas être installé dans un meuble encastré comme une bib-
liothèque ou une étagère à moins de lui fournir une ventilation adéquate ou que l’installation
soit conforme aux directives du manufacturier.
11. Sources d’alimentation électrique—Cet appareil devrait être utilisé seulement avec
le type d’alimentation électrique inscrite sur l’étiquette. Si vous n’êtes pas certain du type
d’alimentation électrique fourni à votre maison, consultez le vendeur de l’appareil ou
l’entreprises d’énergie locale. Pour des appareils alimentés par une batterie ou d’autres
sources, se référer aux consignes d’utilisation.
12. Mise à la terre ou Polarisation—Cet appareil est équipé avec un cordon d’alimentation
à trois fils. Il est a brancher sur une prise ayant un connecteur a la terre. Assurez-vous que la
connection a la terre ne manque pas.
13. Protection du cordon d’alimentation—Les cordons d’alimentation devraient être dispo-
sés de façon à ce qu’on ne puisse marcher dessus ou qu’ils soient susceptibles d’être coincés
par des articles placés sur ou contre eux. Une attention particulière doit être portée aux
fiches, prises de courant, et aux points où ils sortent de l’appareil.
14. Mise à la terre de l’antenne extérieure—Si un système extérieur d’antenne ou de câble
est relié à l’appareil, s’assurer que le système d’antenne ou de câble est muni d’une mise à la
terre afin de fournir une certaine protection contre les surtensions et les charges d’électricité
statique. L’article 810 du code électrique national, ANSI/NFPA 70, fournit l’information néces-
saire en ce qui concerne la mise à la terre appropriée du mât et de la structure porteuse,
la mise à la terre du câble de connexion à une unité de décharge d’antenne, le calibre des
conducteurs de mise à la terre, la location de l’unité de décharge d’antenne, le raccordement
aux électrodes de mise à la terre et les spécifications pour les électrodes de mise à la terre.
Voir la figure A.
15. Foudre—Pour une protection supplémentaire de cet appareil pendant un orage élec-
trique, ou quand il est laissé sans surveillance et inutilisé pendant de longues périodes, le
débrancher de la prise électrique murale et déconnecter le système d’antenne ou de câble.
Ceci préviendra les dommages à l’appareil dus à la foudre et aux surtensions.
16. Lignes électriques—Un système d’antenne extérieur ne devrait pas être situé à proximité
de lignes électriques aériennes ou de tout autre circuit électrique, où il pourrait tomber sur
de tels circuits ou lignes électriques. Lors de l’installation d’un système d’antenne extérieur,
d’extrêmes précautions devraient être prises afin de prévenir tout contact avec des lignes ou
circuits électriques. Entrer en contact avec de tels circuits ou lignes électriques pourrait être
fatal.
17. Surcharge—Ne pas surcharger les prises de courant murales, les rallonges électriques ou
les prises de courant intégrées. Un risque d’incendie ou de choc électrique pourrait résulter
d’une telle surcharge.
18. Insertion d’objet ou de liquide—Ne jamais insérer d’objet par les ouvertures de cet
appareil. Il pourrait toucher des points de voltage dangereux ou court-circuiter des pièces,
ce qui pourrait résulter en incendie ou en choc électrique. Ne jamais verser de liquide sur
l’appareil.
19. Entretien—Ne pas essayer de faire soi-même l’entretien de cet appareil. En ouvrir ou en
retirer les couvercles pourrait vous exposer à des voltages dangereux ou à d’autres dangers.
Confier tout entretien à un personnel de service qualifié.
20. Dommage exigeant un entretien—Débrancher cet appareil de la prise de courant élec-
trique et confier l’entretien au personnel de service qualifié dans les éventualités suivantes:
a. Quand le cordon d’alimentation ou sa fiche sont endommagés,
b. Si des objets sont tombés dans l’appareil, ou si du liquide y a été renversé,
c. Si l’appareil a été exposé à la pluie ou à l’eau,
d. Si l’appareil ne fonctionne pas normalement en suivant les consignes d’utilisation.
Ajuster seulement les commandes qui sont mentionnées dans le guide d’opération. Un
mauvais ajustement des autres commandes pourrait causer des dommages à l’appareil et
souvent exiger un travail supplémentaire de la part d’un technicien qualifié pour remettre
l’appareil en état normal d’opération.
e. Si l’appareil a été échappé ou endommagé de n’importe quelle façon, et
f. Quand l’appareil montre un changement notable de performance – ceci indique qu’un
entretien est nécessaire.
21. Pièces de rechange—Si des pièces de rechange sont nécessaires, s’assurer que le tech-
nicien de service a employé des pièces de rechange spécifiques du manufacturier ou ayant
les mêmes caractéristiques que les pièces originales. L’utilisation de pièces de rechange non
autorisées pourrait résulter en incendie, choc électrique ou autres dangers.
22. Vérification de sécurité—À la suite de toute réparation ou entretien de cet appareil,
demander au technicien de service d’exécuter des vérifications de sécurité afin de s’assurer
que l’appareil est en condition normale de fonctionnement.
23. Montage au mur ou au plafond—L’appareil ne devrait être monté au mur ou au plafond
qu’uniquement de la façon recommandée par le manufacturier.
24. Chaleur—L’appareil devrait être situé loin de sources de chaleur telles que des radia-
teurs, des registres de chaleur, des fourneaux, ou d’autres appareils (y compris amplifica-
teurs) produisant de la chaleur.
NOTE AUX INSTALLATEURS DE SYSTÈME DE CATV:
CE RAPPEL EST FOURNI POUR PORTER À L’ATTENTION DES
INSTALLATEURS DE SYSTÈME DE CATV, L’ARTICLE 820 - 40 DU
NEC QUI DONNE DES DIRECTIVES POUR UNE MISE À LA TERRE
APPROPRIÉE ET, EN PARTICULIER, SPÉCIFIE QUE LE CÂBLE DE
MISE À LA TERRE DEVRAIT ÊTRE RACCORDÉ AU SYSTÈME DE
MISE À LA TERRE DU BÂTIMENT LE PLUS PRÈS POSSIBLE DE
L’ENTRÉE DU CÂBLE.
FIGURE A
Exemple de mise à la terre d’antenne selon le Code Électrique National, ANSI/NFPA 70
ANTENNA
LEAD IN
WIRE
UNITÉ DE DÉCHARCHE D’ANTENNE
(NEC SECTION 810-20)
CONDUCTEURS DE MISE À LA TERRE
(NEC SECTION 810-21)
SYSTÈME DE MISE À LA TERRE DU BÂTIMENT
(NEC ART 250, PART H)
APPAREILS
ÉLECTRIQUES
DE SERVICE
ATTACHES DE
MISE À LA TERRE
ATTACHES DE
MISE À LA TERRE
NEC - CODE ÉLECTRIQUE NATIONAL
AVERTISSEMENT: AFIN D’ÉVITER TOUT RISQUE D’INCENDIE
OU D’ÉLECTROCUTION, NE PAS EXPOSER CET APPAREIL À LA
PLUIE OU À L’HUMIDITÉ.
RISQUE DE CHOC ELECTRIQUE -
NE PAS OUVRIR
ATTENTION: POUR RÉDUIRE LE RISQUE D’ÉLECTROCUTION, NE PAS
ENLEVER LE DOS DE L’APPAREIL NI OUVRIR LE BOÎTIER. AUCUNE PIÈCE N’EST
RÉPARABLE PAR L’UTILISATEUR À L’INTÉRIEUR. SE RÉFÉRER UNIQUEMENT À
DES TECHNICIENS QUALIFIÉS POUR L’ENTRETIEN.
! AVERTISSEMENT !
Une combinaison de l’appareil et chariot doit être déplacé avec précaution. Des arrêts
brusques, une force excessive et des surfaces inégales peuvent causer la combinaison
de l’appareil et le chariot.
Le point d’exclamation à l’intérieur d’un triangle équilatéral est destiné à alerter
l’utilisateur sur la présence d’opérations d’entretien importantes au sujet desquelles des
renseignements se trouvent dans le manuel d’instructions.
Le symbole de l’éclair à l’intérieur d’un triangle équilatéral est destiné à alerter
l’utilisateur sur la présence d’une “tension dangereuse” non isolée dans le boîtier du
produit. cette tension est suffisante pour provoquer l’électrocution de personnes.
ATTENTION DÉCLARATION
AVERTISSEMENT: AFIN D’ÉVITER TOUT RISQUE D’INCENDIE OU D’ÉLECTROCUTION, NE PAS
EXPOSER CET APPAREIL À LA PLUIE OU À L’HUMIDITÉ. NE PAS OUVRIR LE
BOÎTIER, CONFIER TOUS TRAVAUX À DU PERSONNEL TECHNIQUE QUALIFIÉ.
CAUTION: POUR PREVENIR LES CHOCS ELECTRIQUES, NE PAS UTILISER CETTE FICHE
POLARISEE AVEC UN PROLONGATEUR, UNE PRISE DE COURANT OU UNE
AUTRE SORTIE DE COURANT, SAUF SI LES LAMES PEUVENT ETRE INSEREES A
FOND SANS EN LAISSER AUCUNE PARTIE A DECOUVERT.
800-523-6049 | www.rldrake.com
Specifications
INTERFACE
AUDIO OPTIONS
VIDEO INPUTS:
SD/HD-SDI BNC Type Input Connection
Composite Video RCA Input Connector
Closed Caption Support (embedded only)
AUDIO INPUTS:
SD/HD-SDI Embedded PCM Audio
Analog Audio (L, R) 2xRCA Input Connectors
Supports Audio Gain Adjustment
ENCODER FORMAT:
Dolby® Digital, AAC, or MPEG1-Layer 2
OUTPUT BIT RATE:
128, 192, 224, or 384 Kbps
Manufactured under license from Dolby Laboratories
VIDEO OPTIONS
OUTPUT
INPUT VIDEO MODES:
480i (640x480/720x480 @ 30 FPS)
720p (1280x720 @ 60 FPS)
1080i (1920x1080 @ 30, 59.94 & 60 FPS)
AUTO-SCAN for Input Resolution
VIDEO FORMAT:
MPEG-2 OR H.264
VIDEO ADJUSTMENTS:
BRIGHTNESS
CONTRAST
HUE
SATURATION
H.264 PROFILE SUPPORT:
BASELINE
MAIN
HIGH
VIDEO OUTPUT:
SFP Port IP SPTS (SFP sold separately)
PACKET FORMAT:
UDP SPTS (two HD or SD streams)
ZIXI:
UDP Transport Stream Protocol
PHYSICAL SPECIFICATIONS
TEMPERATURE RATING:
0 - 50° C Ambient
FORM FACTOR:
Desktop Modulator
DIMENSIONS:
Approximately 7.6” D X 2.0” H X 8.7” W
WEIGHT:
1.5 lbs
POWER REQUIREMENTS:
100-120 VAC/60 Hz
Available SFPs (sold separately)
Item #
Model
Description
1002620
SFP-C-10/100/1000 Transceiver
10/100/1000BASE-T SFP, RJ-45, 100M, COPPER
1002621
SFP-MM-850-550M
1000BASE-SX SFP, 850NM, 550M, MMF, DDM
1002622
SFP-SMF-1310-10KM
1000BASE-LX SFP, 1310NM, 10KM, SMF, DDM
1002670
SFP-SMF-1310-40KM
1000BASE-LX SFP, 1310NM, 40KM, SMF, DDM
1002623
SFP-SMF-1550-80KM
1000BASE-ZX SFP, 1550NM, 80KM, SMF, DDM
1002624
SFP-SMF-CWDM-1470nm-80KM
1.25GBASE-CWDM-SFP, 1470NM, 80KM, SMF, DDM
1002625
SFP-SMF-CWDM-1490nm 80KM
1.25GBASE-CWDM-SFP, 1490NM, 80KM, SMF, DDM
1002626
SFP-SMF-CWDM-1510nm-80KM
1.25GBASE-CWDM-SFP, 1510NM, 80KM, SMF, DDM
1002627
SFP-SMF-CWDM-1530nm-80KM
1.25GBASE-CWDM-SFP, 1530NM, 80KM, SMF, DDM
1002628
SFP-SMF-CWDM-1550nm-80KM
1.25GBASE-CWDM-SFP, 1550NM, 80KM, SMF, DDM
1002629
SFP-SMF-CWDM-1570nm-80KM
1.25GBASE-CWDM-SFP, 1570NM, 80KM, SMF, DDM
1002630
SFP-SMF-CWDM-1590nm-80KM
1.25GBASE-CWDM-SFP, 1590NM, 80KM, SMF, DDM
1002631
SFP-SMF-CWDM-1610nm-80KM
1.25GBASE-CWDM-SFP, 1610NM, 80KM, SMF, DDM
1002632-XX
SFP-SMF-DWDM-CHXX-40KM
1.25GBASE-DWDM-SFP, CH. 20-59 ,40KM, SMF, DDM
1002633-XX
SFP-SMF-DWDM-CHXX-80KM
1.25GBASE-DWDM-SFP, CH. 20-59, 80KM, SMF, DDM
Last 2 numbers indicate channel number (20-59).
PEG PLUS • Item # 1002613B
MPEG-2 or H.264 Digital Video PEG Encoder with HD-SDI or Composite Input and IP Output
Specifications are subject to change without notice or obligation.
Dolby is a registered trademark of Dolby Laboratories.
800-523-6049 | www.rldrake.com
INTRODUCTION
The PEG PLUS is a stand-alone MPEG-2 or H.264 digital video PEG channel encoder with a single SD/HD-SDI, or composite
video input, and an IP-encapsulation output via a single SFP Ethernet port. A separate RJ45 10/100 Ethernet port is provided
for control and monitoring capability.
The PEG PLUS features selectable SDI PCM-embedded audio, or analog left and right audio. Audio compression can be
either Dolby® Digital, MPEG1-Layer 2 stereo, or AAC stereo.
An optional Zixi output protocol is also available to provide the ability to stream content in H.264 format over an unmanaged
network, including the public internet. The Zixi UDP-based video optimized protocol provides professional broadcasters,
sports networks, and service providers a mechanism to adapt to the public internet using standard IP networks as a way to
ingest and transport broadcast quality video.
An optional rack mount panel is available for up to (2) PEG PLUS encoders.
General Description & Features
Model
Item #
Description
PEG PLUS
PEG-RP-2
1002613B
1002613B Z
1002644B
MPEG-2 or H.264 HD PEG Encoder with HD-SDI or Composite Input
and IP Output
MPEG-2 or H.264 HD PEG Encoder with Zixi Option
Rack Mount Panel for (2) PEG PLUS units
PEG-RP-2 with (2) PEG PLUS units
FEATURES
• MPEG-2 or H.264 video encoding
• Selectable SD/HD-SDI or Composite video input
• Encodes two HD or SD streams of the same content in either MPEG-
2 or MPEG-4/H.264 formats
• Supports video resolutions of 480i, 720p, or 1080i
• Selectable SDI PCM-embedded audio or analog L+R audio
• Dolby® Digital, AAC, or MPEG1-Layer 2 stereo audio encoding from
PCM-embedded audio source
• IP output via SFP port (SFP sold separately)
• Unicast and multicast capable
• Separate Management port and streaming port
• Built-in watchdog timer with system reboot capability
• Field-upgradable firmware
• Configuration and shutdown control via HTTP server UI and
programmable API
• Supports VLAN & QoS for streaming or traffic mgmt.
• SNMP V2
• User-defined PID configuration
• Supports ATSC PSIP tables
• DVB Service information table generation (NIT+SDT)
• Insert custom screen message upon loss of video
• Compositing support to add program PNG logo file
800-523-6049 | www.rldrake.com
REAR PANEL
NTSC Composite Video/Audio In: Analog video with Left and Right Audio.
HD-SDI In: Digital video HD/SD SDI input.
SFP Ethernet Output: Optical or Copper SFP IP video and audio output. (SFP sold separately)
5VDC Power Port: Accepts 5 volt (VDC) power to the unit.
FRONT PANEL
Ethernet Control: 10/100 Ethernet wired connection for local and remote management
IP Reset Button: When pressed for >2 seconds, the IP address of the control port will enable to the default factory IP
address (172.16.70.1, Subnet Mask 255.255.255.0) The login credentials will also be enabled to the default username
“admin” and password “pass”.
NOTE: The old IP address, login, and password will still be present in the encoder settings.
Status LEDs provide a status of tasks performed by the PEG PLUS encoder in real-time:
Power: LED is illuminated when the power is ON.
Input: LED is illuminated when input video is being received from the HD/SD SDI or Composite input.
Encoding: LED is illuminated when the internal encoder is operational.
Output: LED is illuminated when the copper or optical SFP is connected to a network.
Front and Rear Panel Operation
1
2
3
4
7
5
8
6
9
10
7
3
1
4
2
5
6
8
9
10
800-523-6049 | www.rldrake.com
Installation & Power-Up
Unpacking
You will find the following items in the box:
• PEG PLUS Encoder Unit (QTY = 1)
• Power Adapter (QTY = 1)
Power-Up
Plug the Power Adapter into a power plug (120 VAC, 60Hz). Plug the power pin into the back of the PEG unit at the input
marked “DC Power”.
For safe and reliable operation, only use the power adapter supplied with the PEG PLUS Encoder.
For safe and reliable operation, do not place objects within 1 inch of the unit that blocks the airflow.
A 1RU (1.75”) open space must be provided above the PEG PLUS encoders when mounted in a 19 inch rack or cabinet
to allow air flow for encoder heat dissipation. Drake’s PEG-RP-2 accessories or a standard 19” rack shelf can be used for
mounting 2 PEG PLUS encoder modules in 1RU.
Installation
The PEG PLUS Encoder is designed to be mounted on a desktop in close proximity to a 120 VAC, 60Hz power outlet.
800-523-6049 | www.rldrake.com
Login Screen
First, connect the appropriate input and output video cables and plug in the PEG PLUS power cable.
ETHERNET ACCESS:
Local or remote communication with the unit is only possible through a GUI-based menu via any standard web browser
Chrome or Firefox is recommended. Before you can communicate with the unit you must configure your computers Local
Area Network connection to confirm with the PEG PLUS default IP of 172.16.70.1. To do so, follow these steps:
Connect an Ethernet cable from your computer to the Control 10/100 port of the PEG PLUS.
1. The following steps explain how to do this for a PC with Windows XP operating software:
a) On your computer, open the "Control Panel"
b) Double-click on "Network Connections"
c) Right-click on the "Local Area Connection", and then click on the "properties".
d) A dialog box entitled "Local Area Connection Properties" will appear. In this box, double-click on the "Internet Protocol
(TCP/IP)".
e) A dialog box entitled "Internet Protocol (TCP/IP) Properties" will appear. Select the "Use the following IP address"
option and enter the following addresses:
IP address: 172.16.70.2
Subnet mask: 255.255.255.0
Default Gateway: No need to enter a value for local access.
Click OK to close dialog box. Your computer is now ready to communicate with the unit.
- OR -
2. The following steps explain how to do this for a PC with Windows 7, Windows 8.x or Windows 10 operating software:
a) On your computer, navigate to the "Network and Sharing Center". (Note: This can be found using the search box in
the Start Menu or for Windows 8.x, the Start Screen)
b) Once open, click on “Change Adapter Settings” on left hand side of the window.
c) Right-click on the "Local Area Connection", and then click on the "Properties".
d) A dialog box entitled "Local Area Connection Properties" will appear. In this box, double-click on the
"Internet Protocol Version 4 (TCP/IPv4)".
e)
A dialog box entitled "Internet Protocol Version 4 (TCP/IPv4) Properties" will appear. Select the
"Use the following IP address" option and enter the following addresses:
IP address: 172.16.70.2
Subnet mask: 255.255.255.0
Default Gateway: No need to enter a value for local access.
Click OK to close dialog box. Your computer is now ready to communicate with the unit.
Figure 1 - "Login" Screen
Open a Chrome or Firefox web browser on your computer and enter the following
URL address (http://172.16.70.1). Once the PEG PLUS web server has been
loaded from your browser, you should see the login dialog.
Enter the username and password and click LOG IN. The default username is
"admin" (in lower case letters) and the default password is "pass" (in lower case
letters).
NOTE: If you have any issues connecting to the PEG PLUS encoder, we
recommend clearing the cache in the browser’s settings.
IMPORTANT: The front-panel Control Port (Management Port) and the rear-
panel SFP Port MUST be on different subnets. See "Networking Section"
800-523-6049 | www.rldrake.com
Status Tab
System Information
CPU Usage: Indicates the total usage of CPU resources and the encoder CPU usage.
Serial Number: Indicates serial number of PEG PLUS encoder
Hardware Version: Indicates the hardware version of the PEG PLUS encoder
Software Version: Indicates the software version of the unit
Unit Name and Location: Indicates user-defined unit constants set under the "System Tab: Networking" section.
Up-Time: Indicates the uptime of the unit expressed in days, hours, minutes, and seconds.
System Time (UTC): The system time can be synced up with the browser time by using the controls under the System
menu and will be displayed in UTC time format.
1
2
5
6
3
7
4
Figure 2a - "Status" Tab (Read-Only)
2
1
3
4
6
7
8
9
11
12
13
5
10
Input Status Box
Status: Indicates the status of the input.
Firmware Version: Indicates the current firmware version.
SDI Input and Format: Input indicates if the video is present and locked.
Format indicates resolution (see Figure 2b).
Composite Input and Format: Input indicates if the video is present and locked. Format indicates resolution (see
Figure 2b).
Active Video Source: Indicates the current active video source(s) and resolution (see Figure 2b).
Active Audio Source: Indicates if there is embedded audio on the stream(s).
8
11
12
9
13
10
PEG PLUS supports resolutions of:
480i (640x480/720x480 @ 30 FPS)
720p (1280x720 @ 60 FPS)
1080i (1920x1080 @ 30, 59.94, & 60 FPS)
Figure 2b
800-523-6049 | www.rldrake.com
A/V Source Selection
Source: Video input selection of SDI or Composite
Audio Adjustments
Audio Sync Adjustment: Audio/video lip-sync adjustment used to adjust the audio to video synchronization. For
example, you may need to delay or lag the audio if the video input is SDI and the audio source is analog. Range is +/-
500ms.
Encoder Tab AV Input
:
Status Tab with Zixi
AV Input - Source Settings
1
2
Figure 3 - "Encoder" Tab - AV Input
2
1
3
5
4
6
ZIXI Stream Status Box
Status: Indicates the status of the input.
Host IP: User defined IP address or host name. The
public IP address of the device (Decoder or Broadcaster)
you are streaming to.
Conn. Up Time: Indicates the uptime of connection.
Reconnects: Indicates the number of reconnections.
Bitrate: Indicates the transport stream bitrate of the
encoder.
Tx Bytes: Indicates the transmit bytes being sent.
14
17
15
18
16
19
14
15
16
17
18
19
Figure 2c
800-523-6049 | www.rldrake.com
Composite Video Adjustments
Brightness: Range is +/- 30 (increments of 1)
Contrast: Range is 0.3 to 2.0 (increments of 0.1)
Saturation: Range is 0 to 2.0 (increments of 0.1)
Hue Shift (degrees): Range is -89.6 to +85.4 (increments of 0.3)
Encoder Tab: AV Input
Audio Codec: Options are: MP2 for MPEG-1 Audio Layer 2, AC-3 for Dolby Digital (AC-3), or AAC (Advanced Audio
Coding)
Audio Bitrate: Options are: 128, 192, 224, or 384 Kbps.
Audio DialNorm: behaves as an audio Automatic Gain Control (AGC) or Dynamic Range Control (DRC). It has the
ability to take different incoming audio levels and normalize them. The ability of the Dialog Normalization depends on
the configuration of the Dynamic Range Control. The encoder allows you to adjust the normalization from -1 to -31 dB.
The typical value is -27 dB. This is based on the standard film audio formats which normally are between -25 and -31 dB.
5
6
3
4
Figure 4a - "Encoder" Tab - Encoding - Audio Encoder Settings
1
3
2
1
2
3
Audio Encoder Settings (Figure 4a)
AV Input - Source Settings (continued, see Figure 3)
Stream 1: MPEG-4/AVC HD (See Figure 4b, next page)
Video Encode
Video Bitrate, HD Input: Range is 3.5 to 13 (incremented by 0.1)
NOTE: Once an input is applied, only the detected resolution (SD or HD) will be displayed. Both SD & HD video bitrates are
displayed only when no input is detected.
Video Bitrate, SD Input: Range is 1 to 4 (incremented by 0.1)
P-Frames per GOP: Specifies total number of P frames in a Group-of-Pictures (GOP). Options are 0, 1, 2, 3, 4, 5, 9,
14, and 29.
B-Frames per I/P-Frame: Specifies number of B frames between each I or P frame in a GOP. Range is 1.3 to 4.
NOTE: When streaming H.264 HD stream the default P-Frame per GOP is 14 and the default B-Frame between I/IP is 3, which
gives you a default Total GOP Length of 60.
7
4
5
6
Encoder Tab Encoding
:
800-523-6049 | www.rldrake.com
Transport Stream
Transport Bitrate, HD Input: Range is 4.125 to 25 (incremented by 0.125)
Transport Bitrate, SD Input: Range is 0.625 to 25 (incremented by 0.125)
NOTE: TS Bitrate must be greater than 0.400 Mbps + audio bitrate + video bitrate.
Transport Stream ID: Configures the transport stream ID number used Program Specific Information (PSI) tables in
the stream. Range is 1 - 65,535.
Program Number: Configures the MPEG Program used in all PSI tables for this stream. Range is 1 - 65,535.
PMT PID: Configures the Packet Identifier (PID) used to transmit all Program Map Tables in the stream.
Video PID: Configures the PID used to transmit Video and associated data.
Audio PID: Configures the PID used to transmit audio and associated data.
NOTE: All PIDs are displayed in Hex format. If you type a decimal format into the field, the GUI will automatically convert your
decimal format to a Hex value. PIDs are expressed in both decimal & hex formats to the right of the entry field.
Service Info Type: Default value is "None"
If set to "DVB/SI", the following fields are enabled:
DVB Network Name - user-specified field for the "Network Name" in the DVB NIT table.
DVB Service Name and DVB Provider Name - user-specified field for these fields in the DVB SDT table.
If set to "ATSC/PSIP", the following fields are enabled:
VCT Short Name: 7-letter name for the channel.
Major Channel Number - Specifies the Major Channel Number in the VCT. Range is 1 - 999.
Minor Channel Number - Specifies the Minor channel number in the VCT. Range is 1 - 999.
Stream 1: MPEG-4/AVC HD (continued, see Figure 4b)
Encoder Tab: Encoding
12
13
14
15
11
8
9
10
Figure 4b - "Encoder" Tab - Encoding - Stream 1: MPEG-4/AVC HD
4
8
12
6
10
14
5
9
13
7
11
15
800-523-6049 | www.rldrake.com
Encoder Tab: Encoding
Video Encode
Video Bitrate: Range is 1 to 4 (incremented by 0.1)
P-Frames per GOP: Specifies total number of P frames in a Group-of-Pictures (GOP). Options are 0, 1, 2, 3, 4, 5, 9,
14, and 29.
B-Frames per I/P-Frame: Specifies number of B frames between each I or P frame in a GOP. Range is 1.3 to 4.
NOTE: When streaming MPEG-SD stream the default P-Frame per GOP is 4 and the default B-Frame between I/IP is 2, which
gives you a default Total GOP Length of 15.
Transport Stream
Transport Bitrate, SD Input: Range is 0.625 to 25 (incremented by 0.125)
NOTE: TS Bitrate must be greater than 0.400 Mbps + audio bitrate + video bitrate.
Transport Stream ID: Configures the transport stream ID number used Program Specific Information (PSI) tables in
the stream. Range is 1 - 65,535.
Program Number: Configures the MPEG Program used in all PSI tables for this stream. Range is 1 - 65,535.
PMT PID: Configures the Packet Identifier (PID) used to transmit all Program Map Tables in the stream.
Video PID: Configures the PID used to transmit Video and associated data.
Audio PID: Configures the PID used to transmit audio and associated data.
NOTE: All PIDs are displayed in Hex format. If you type a decimal format into the field, the GUI will automatically convert your
decimal format to a Hex value. PIDs are expressed in both decimal & hex formats to the right of the entry field.
Service Info Type: Default value is "None"
If set to "DVB/SI", the following fields are enabled:
DVB Network Name - user-specified field for the "Network Name" in the DVB NIT table.
DVB Service Name and DVB Provider Name - user-specified field for these fields in the DVB SDT table.
If set to "ATSC/PSIP", the following fields are enabled:
VCT Short Name: 7-letter name for the channel.
Major Channel Number - Specifies the Major Channel Number in the VCT. Range is 1 - 999.
Minor Channel Number - Specifies the Minor channel number in the VCT. Range is 1 - 999.
Stream 2: MPEG-4/AVC SD (Figure 4c)
23
24
25
16
17
18
19
20
21
22
Figure 4c - "Encoder" Tab - Encoding - Stream 2: MPEG-4/AVC SD
16
19
23
18
21
25
17
20
24
22
800-523-6049 | www.rldrake.com
Video Encode
Video Bitrate, HD Input: Range is 3.5 to 13 (incremented by 0.1)
NOTE: Once an input is applied, only the detected resolution (SD or HD) will be displayed. Both SD & HD video bitrates are
displayed only when no input is detected.
Video Bitrate, SD Input: Range is 1 to 4 (incremented by 0.1)
GOP Length: Group-of-Pictures (GOP) length. Range is 1 to 127 (incremented by 1). Default value is 15
Transport Stream
Transport Bitrate, HD Input: Range is 4.125 to 25 (incremented by 0.125)
Transport Bitrate, SD Input: Range is 0.625 to 25 (incremented by 0.125)
NOTE: TS Bitrate must be greater than 0.400 Mbps + audio bitrate + video bitrate.
Transport Stream ID: Configures the transport stream ID number used Program Specific Information (PSI) tables in
the stream. Range is 1 - 65,535.
Program Number: Configures the MPEG Program used in all PSI tables for this stream. Range is 1 - 65,535.
PMT PID: Configures the Packet Identifier (PID) used to transmit all Program Map Tables in the stream.
Video PID: Configures the PID used to transmit Video and associated data.
Audio PID: Configures the PID used to transmit audio and associated data.
NOTE: All PIDs are displayed in Hex format. If you type a decimal format into the field, the GUI will automatically convert your
decimal format to a Hex value. PIDs are expressed in both decimal & hex formats to the right of the entry field.
Service Info Type: Default value is "None"
If set to "DVB/SI", the following fields are enabled:
DVB Network Name - user-specified field for the "Network Name" in the DVB NIT table.
DVB Service Name and DVB Provider Name - user-specified field for these fields in the DVB SDT table.
If set to "ATSC/PSIP", the following fields are enabled:
VCT Short Name: 7-letter name for the channel.
Major Channel Number - Specifies the Major Channel Number in the VCT. Range is 1 - 999.
Minor Channel Number - Specifies the Minor channel number in the VCT. Range is 1 - 999.
Encoder Tab: Encoding
31
32
33
34
35
36
29
30
26
27
28
Figure 4d - "Encoder" Tab - Encoding - Stream 3: MPEG-2 HD
26
29
33
28
31
35
27
30
34
36
32
Stream 3: MPEG-2 HD (Figure 4d)
800-523-6049 | www.rldrake.com
Encoder Tab: Encoding
Video Encode
Video Bitrate: Range is 1 to 4 (incremented by 0.1)
GOP Length: Group-of-Pictures (GOP) length. Range is 1 to 127 (incremented by 1). Default value is 15
Transport Stream
Transport Bitrate, SD Input: Range is 0.625 to 25 (incremented by 0.125)
NOTE: TS Bitrate must be greater than 0.400 Mbps + audio bitrate + video bitrate.
Transport Stream ID: Configures the transport stream ID number used Program Specific Information (PSI) tables in
the stream. Range is 1 - 65,535.
Program Number: Configures the MPEG Program used in all PSI tables for this stream. Range is 1 - 65,535.
PMT PID: Configures the Packet Identifier (PID) used to transmit all Program Map Tables in the stream.
Video PID: Configures the PID used to transmit Video and associated data.
Audio PID: Configures the PID used to transmit audio and associated data.
NOTE: All PIDs are displayed in Hex format. If you type a decimal format into the field, the GUI will automatically convert your
decimal format to a Hex value. PIDs are expressed in both decimal & hex formats to the right of the entry field.
Service Info Type: Default value is "None"
If set to "DVB/SI", the following fields are enabled:
DVB Network Name - user-specified field for the "Network Name" in the DVB NIT table.
DVB Service Name and DVB Provider Name - user-specified field for these fields in the DVB SDT table.
If set to "ATSC/PSIP", the following fields are enabled:
VCT Short Name: 7-letter name for the channel.
Major Channel Number - Specifies the Major Channel Number in the VCT. Range is 1 - 999.
Minor Channel Number - Specifies the Minor channel number in the VCT. Range is 1 - 999.
Stream 4: MPEG-2 SD (Figure 4e)
Figure 4e - "Encoder" Tab - Encoding - Stream 4: MPEG-2 SD
37
39
43
41
45
38
40
44
42
42
37
43
38
44
39
45
40
41
IP Output - 1 (Figure 4f)
Enable Output: Options are: Enable or Disable
Source Stream: Each IP Output can be set to one of the following: Stream 1, Stream 2, Stream 3 or Steam 4.
46
47
800-523-6049 | www.rldrake.com
Encoder Tab: Encoding
Figure 4g - "Encoder" Tab - Encoding - IP Output
52
54
56
53
55
57
Enable Output: Options are: Enable or Disable
Source Stream: Each IP Output can be set to one of the following: Stream 1, Stream 2, Stream 3 or Steam 4.
Destination IP / Hostname: Destination unicast or multicast IP address or Hostname determined by the downstream
network device.
Destination Port: Destination port assigned to the IP or Hostname of the IP Output
TTL (Time to Live): See "#50, IP Output - 1" for description on this setting. The range is 1 to 255 and is incremented
by 1. (Factory Default: "128").
DiffServ / DSCP: See "#51, IP Output - 1" for description on this setting. Configures the value of the differentiated
services code point (DSCP) field in the IPv4 header for the video output stream. (See Figure 4f for options)
Press the "Apply" button to apply the settings.
52
53
54
55
56
57
Destination IP / Hostname: Destination unicast or multicast IP address or Hostname
determined by the downstream network device.
Destination Port: Destination port assigned to the IP or Hostname of the IP Output
TTL (Time to Live): TTL is an upper bound on the time that an IP packet can exist in an
IP network. The value is set by the sender of the packet, and reduced by every host on
the route to packet’s final destination. If the Time to Live reaches zero before the packet
arrives at its final destination, then the packet is discarded. The purpose of this field is to avoid an undeliverable packet
from circulating on an IP network perpetually. The range is 1 to 255 and is incremented by 1. (Factory Default: "128").
DiffServ / DSCP: Configures the value of the differentiated services code point (DSCP) field in the IPv4 header for the
video output stream. The format of this field is specified by IETF RFC2474, but actual values are specified by several
related RFCs. The encoder does not support explicit congestion notification (ECN) which makes use of the lower 2 bits
of this header field. (See Figure 4f for available options)
48
49
50
51
Figure 4f - "Encoder" Tab - Encoding - IP Output
46
48
50
47
49
51
IP Output - 1 (continued, see Figure 4f)
IP Output - 2 (Figure 4g)
800-523-6049 | www.rldrake.com
Zixi Output Settings
When setting up the Zixi option version of the encoder, the user will first need to insert the License Key within the Admin
Panel (see page 27). Once this is done, the Zixi Output sections for Stream 1 and 2 will show up as follows in the Encoder
Tab: Encoding Screen, under the IP Output sections (See Figure 4h):
To begin setting up the Zixi Outputs:
Click on the plus (+) sign next to each Output section title (See Figure 4h) in order to expand the section.
All settings may now be seen (See Figure 4i). To close the section again, simply click the minus (-) sign in the title.
The following options can now be set for Zixi Output Stream 1 and Stream 2:
Zixi Output (Stream 1) (See Figure 4j, next page)
Enable Output: Options are Enable or Disable.
Channel: Uniquely identifies a given stream on the port. Several streams can be “multiplexed” on the same UDP port.
Password: Used to prevent unauthorized connections but does not encrypt the stream. The encoder's password MUST
match the decoder's password. Note: An empty field is equivalent to no password.
Max Latency: Used to set maximum allowed latency of the stream over the Zixi protocol. Units are in milliseconds and
are numeric values ranging from 100 to 5000 in increments of 100. Default option is “Auto”.
a) Setting Max Latency to a low value means more forward error correction (FEC) is needed to guarantee stream
delivery.
b) Setting Max Latency to a higher value allows the Zixi layer to use re-transmission instead of / in addition to FEC.
NOTE: In general, higher latency yields lower CPU load on the encoder and less overhead on the data rate.
Hostname/IP Address: User-defined IP address or host name.
Port: The UDP port used for communicating from the encoder-to-broadcaster. Default port used by Zixi broadcasters
is "2088".
58
59
Figure 4h - "Encoder" Tab - Encoding
Zixi Output: Stream 1 & 2 (Closed)
58
60
61
62
63
64
65
Figure 4i - "Encoder" Tab - Encoding
Zixi Output: Stream 1 & 2 (Open)
59
Encoder Tab Encoding (Zixi)
:
800-523-6049 | www.rldrake.com
Zixi Output (Stream 2) (Figure 4k)
Enable Output: Options are Enable or Disable.
Channel: Uniquely identifies a given stream on the port. Several streams can be "multiplexed" on the same UDP port.
Password: Used to prevent unauthorized connections but does not encrypt the stream. The encoder's password MUST
match the decoder's password. Note: An empty field is equivalent to no password.
Max Latency: Used to set maximum allowed latency of the stream over the Zixi protocol. Units are in milliseconds and
are numeric values ranging from 100 to 5000 in increments of 100. Default option is "Auto".
a) Setting Max Latency to a low value means more forward error correction (FEC) is needed to guarantee
stream delivery.
b) Setting Max Latency to a higher value allows the Zixi layer to use re-transmission instead of / in addition
to FEC.
NOTE: In general, higher latency yields lower CPU load on the encoder and less overhead on the data rate.
Hostname/IP Address: User-defined IP address or host name.
Port: The UDP port used for communicating from the encoder-to-broadcaster. Default port used by Zixi broadcasters
is "2088".
Press the "Apply" button to apply the settings.
Zixi Output (Stream 1) (continued, see Figure 4j)
Encoder Tab: Encoding (Zixi)
Figure 4k - "Encoder" Tab - Encoding - Zixi Output: Stream 2 (example)
66
68
70
67
69
71
66
67
68
69
70
71
Figure 4j - "Encoder" Tab - Encoding - Zixi Output: Stream 1 (example)
60
62
64
61
63
65
800-523-6049 | www.rldrake.com
Compositing allows for an overlay of a static image upon loss of video input. It supports PNG file format and displays only
when an image file has been uploaded.
PLEASE NOTE:
"Overlay for No Input (480i)," image resolution must be 720x480.
"Overlay for (720p)," image resolution must be 280x720.
"Overlay for (1080i)," image resolution must be 1920x1080.
Figure 5 - "Encoder Configuration - Compositing"
Encoder Tab Compositing
:
800-523-6049 | www.rldrake.com
Figure 6 - "System" Tab - Networking - System Configuration
1
3
2
4
5
6
7
System Tab Networking
:
The system configuration tab allows the user to set Ethernet and SNMP settings.
800-523-6049 | www.rldrake.com
DNS Settings:
DNS Mode: Options are DHCP Provided or Manual mode. When in manual mode, enter Primary, Secondary name
servers and/or Search Domains in the space provided.
Name Servers: Read-only field that indicates conversion from domain names to IP addresses.
To set system time you will need to set the IP address of your local DNS server by configuring DNS Mode to “manual.”
The encoder will then resolve the standard NTP server pool DNS entry and sync the system time.
Setting the UTC Time:
Method 1A:
1. Set DHCP enable on SFP Video
2. Enable HTTP Server
3. Set DNS settings to DHCP Provided
Method 1B:
1. Set DHCP to disable on SFP Video
2. Enter your desired IP Address and a valid gateway
3. Enable HTTP Server
4. Set DNS Settings to Manual
5. Under Primary DNS, enter your network DNS
6. If none is available, you can use google DNS of 8.8.8.8, but your gateway must be able to reach the internet.
Method 1C:
1. Set valid IP under control port settings and a valid gateway
2. Set DNS Settings to Manual
3. Under Primary DNS, enter your network DNS
4. If none is available, you can use google DNS of 8.8.8.8, but your gateway must be able to reach the internet.
System Tab: Networking
SFP Video Network Settings:
Mac Address: read-only field that indicates the MAC Address of the “SFP Output” Port.
DHCP Enable: Enables or Disables DHCP on the SFP Output.
IP address: the static IP address that is assigned to the SFP Network Output. (Default: “172.16.80.1”)
Subnet Mask: the subnet mask address of the SFP Network Output.
Default Gateway: The Gateway Address of the SFP Network Output.
HTTP Server Enable: “Enabled”: This allows management capability on the same SFP port (SFP port IP Address)
as the streaming video.
VLAN Enable: Enables or Disables VLAN.
VLAN Tag: allows the user to set the defined VLAN Tag for the unit.
SFP Control-Only VLAN Settings: Enables or disables VLAN Settings for Control-Only.
Control Port Ethernet Settings: are defined here for the control port.
MAC Address: read-only field that indicates the MAC Address of the “Control 100/1000” Port.
IP Address: the static IP address that is assigned to the unit, allowing the user to access it via the web interface.
Subnet Mask: the Subnet Mask address of the unit, allowing the user to access it from another network via the web
interface.
Default Gateway: the gateway address of unit, allowing the user to access it from another network via the web
interface.
1
3
2
4
IMPORTANT: The front-panel Control Port (Management Port) and the rear-panel SFP Port MUST be on different subnets.
800-523-6049 | www.rldrake.com
The Save/Restore Settings tab enables the user to import and export settings in the PEG PLUS encoder.
Click "Download" to save current configuration settings through a downloaded file.
To upload a saved configuration file, select the file to upload and then click the Upload button.
PLEASE NOTE: A reboot of the encoder is recommended after the config file has been uploaded. (See "Admin Panel"
section)
The PEG PLUS encoder can be remote-managed by using SSH tunneling.
Secure Socket Shell (SSH) is a network protocol that provides administrators with a secure way to access a remote computer
over an unsecured network such as the Internet.
System Tab: Networking
1
2
Figure 7 - "System" Tab - Save and Restore Settings
1
2
Unit Description: Unit Name and User Location are user-defined fields to make identification easier.
SNMP Settings: Simple Network Management Protocol (SNMP) monitoring for the unit. Settings include: Trap Target
IP, Trap Target Port, and System Contact.
Web Settings: User Timeout - Range is 5 to 30 minutes (increments of 5)
5
6
7
System Tab Save/Restore
:
System Tab Remote Management
:
800-523-6049 | www.rldrake.com
Figure 8 - "System" Tab - Remote Management
System Tab: Networking
Basic Setup with SSH Tunneling:
1. Configure an account on an ssh server (that's accessible to the PEG unit), and enable password logins for that account
2. Configure the ssh server's IP (or resolvable hostname, if applicable) in the PEG's "SSH Host" field
3. Configure the ssh server's ssh TCP port in the PEG's "SSH Port" field ('standard' is 22)
4. Enter the username and password for the ssh server account in the PEG's "SSH User" and "SSH Password" fields
5. Enter the port number of the remote (ssh server side) tunnel termination
6. Point a web browser at the ssh server's "Remote Port" configured in step 5 (for instance: "http://SSH_SERVER_
NAME:REMOTE_PORT")
The System Time can be synced up to the current Browser time by using the "Set Encoder Time" button on this page. The
time will be shown in UTC format.
Figure 9 - "Firmware Update" Tab
System Tab Set System Time
:
800-523-6049 | www.rldrake.com
To change/modify the IP network parameters, as well as the Username and Password for the unit, you must be logged in
to the unit as “Admin” to access a hidden screen shown in Figure 12 on the next page. At the top right of the screen select
“Logged in as: admin”.
Admin Username: is the Administrator’s login (10 characters maximum). This login allows the user to make changes to
any area of the unit. Login is case sensitive. (Factory Default: “admin”)
Current Password: is the Administrator’s Current Password (10 characters maximum). Password is case sensitive and
will not be displayed. (Factory Default: “pass”)
Additional Info
Download SNMP MiB: Click on the link to save the encoder's ".mib" file.
Debug Info: Link to a text-only view of Debug Info
Debug Log Archive: Downloadable tar.gz archive file of the Debug Log.
Log Messages
Max Lines to Display: Sets the maximum number of lines to display starting at the most recent.
Level: Available options are are Error, Info, Feedback, Debug and All.
Time Format: Available options are Uptime or Time-of-Day.
Press the "Update" button to apply the settings.
1
2
1
2
Admin Panel
Log Tab
Figure 10 - "Log" Tab - System Log
1
2
800-523-6049 | www.rldrake.com
New Password: used only if the user wants to change the current Administrator’s password. Must enter a new password
(10 characters maximum). Password is case sensitive and will not be displayed.
Confirm Password: must enter the same password as entered in "#3". If password doesn't match, an error message
will be displayed.
Guest Username: is the Guest login (10 characters maximum). This login allows the user to view the unit settings but
does not allow any changes. Login is case sensitive. (Factory Default: “guest”)
Current Password: is the Current Guest Password (10 characters maximum). Password is case sensitive and will not
be displayed. (Factory Default: “pass”)
New Password: used only if the user wants to change the current Guest password. Must enter a new password (10
characters maximum). Password is case sensitive and will not be displayed.
Confirm Password: must enter the same password as entered in "#7". If password doesn't match, an error message
will be displayed.
3
4
5
6
7
Admin Panel
Figure 11 - "Admin" Panel
1
2
3
4
5
7
6
8
9
10
8
800-523-6049 | www.rldrake.com
Firmware Update Tab
Select Firmware Update File: press to browse and select firmware version file
Update: press to initiate firmware update
1
2
2
1
This tab uploads the newest available firmware for the PEG PLUS and deploys firmware to the unit. While the firmware
update tab is actively updating; the logging information and instructions are provided. When the update is completed, the
unit will automatically reboot.
Figure 12 - "Firmware Update" Tab
Admin Panel
System Controls: used to return settings to System Defaults or to Reboot the unit if applying settings through an import
of a configuration file (See System Tab, "Save/Restore" section).
Licensed Features: To enable optionally purchased add-on features (such as Zixi), type in the License Key number
provided by Drake and then press the "Update Key" button.
9
10
Firmware Updates:
For more information regarding the latest product firmware releases, please visit our website at www.
rldrake.com. The Firmware Updates page is available under the "Support" menu option within the
main navigation. General instructions for the FTP site, as well as updating your firmware, are provided
on this page. For further assistance, you may also contact Technical Assistance at 937-746-6990 or
by email: [email protected]
800-523-6049 | www.rldrake.com
A Return Material Authorization (RMA) Number is required on ALL PRODUCT RETURNS (regardless of whether the
product is being returned for repair or for credit). Product that is received at the factory without an RMA Number will be
returned to the sender, unopened.
RMA Numbers must be used when returning product for credit or repair. Use of RMA Numbers will ensure efficient
processing. When needing to return your product to R.L. Drake Holdings, LLC., please follow these simple steps listed
below (in the order that they appear).
Service
1.
Contact R.L. Drake Holdings, LLC.’s Service Department
in one of three ways:
Phone: 800-523-6049
Email: [email protected]
Fax: 732-679-4022
2.
Request from Drake Service a copy of the Product Return
Authorization Form.
3.
Complete the Product Return Authorization Form fully.
4.
Return the completed Product Return Authorization Form
to the Drake Service Department using one of the contact
methods listed in Step 1.
5.
After completing Steps 1 through 4, an RMA Number will
be assigned to you.
6.
Securely pack the product and mark the box with your
RMA Number. If shipping multiple boxes, all boxes must
be marked with the RMA Number. Place the RMA Number
near the return address in large, bold print (approx. 2” in
height).
1.
Contact R.L. Drake Holdings, LLC.’s Service Department
in one of three ways:
Phone: 800-523-6049
Email: [email protected]
Fax: 732-679-4022
2.
Request from Drake Service a copy of the Product Return
Authorization Form.
3.
Complete the Product Return Authorization Form fully.
4.
Return the completed Product Return Authorization Form
to the Drake Service Department using one of the contact
methods listed in Step 1.
5.
After completing Steps 1 through 4, an RMA Number will
be assigned to you.
6.
Securely pack the product in its original undamaged box
(returning the product without its original packaging in
good, new condition may cause the incursion of additional
fees). Pack this box within another shipping container or
box. Mark the shipping box or container with your RMA
Number. Place the RMA Number near the return address
in large, bold print (approx. 2” in height).
Ship your “CREDIT RETURNS ONLY” return to:
R.L. Drake Holdings, LLC.
Attn: Product Credit Returns
One Jake Brown Road
Old Bridge, NJ 08857
Ship your “SERVICE REPAIR ONLY” return to:
R.L. Drake Holdings, LLC.
Attn: Product Service Returns
One Jake Brown Road
Old Bridge, NJ 08857
SERVICE REPAIRS ONLY
CREDIT RETURNS ONLY
*NOTE: All Credit Returns are subject to a 15% Restock Fee
*NOTE: All shipments are to be PRE-PAID by the sender. NO COD’s will be accepted.
IF YOU NEED TECHNICAL HELP
Call our Customer Service/Technical Support line at 800-523-6049 weekdays between 8:00 A.M. and 4:00 P.M. Eastern Standard
Time. Please have the unit’s serial number available. We will also need to know the specifics of any other equipment connected to the
unit. When calling, please have the unit up and running, near the phone if possible. Our technician(s) will likely ask certain questions
to aid in diagnosis of the problem. Also, have a voltmeter handy, if at all possible.
DRAKE also provides technical assistance by
Email: [email protected]
Fax: 732-679-4353
Many of the products that are sent to us for repair are in perfect working order when we receive them. For these units, there is a
standard checkout fee that will be charged. Please perform whatever steps are applicable from the product’s Instruction Manual before
calling or writing as this could save unnecessary phone charges. Please do not return the product without calling Drake Service and
following the steps above first; it is preferred to help troubleshoot the problem over the phone (or by Email) first, saving you both time
and money.
Service
800-523-6049 | www.rldrake.com
Limited Warranty
Blonder Tongue Laboratories, Inc. (BT) will at its sole option, either repair or replace (with a new or factory reconditioned product,
as BT may determine) any product manufactured by BT which proves to be defective in materials or workmanship or fails to
meet the specifications which are in effect on the date of shipment or such other specifications as may have been expressly
agreed upon in writing (i) for a period of one (1) year from the date of original purchase (or such shorter period of time as may
be set forth in the license agreement specific to the particular software being licensed), with respect to iCentral™ (hardware and
software) and all other software products (including embedded software) licensed from BT, (ii)) for a period of one (1) year from
the date of original purchase, with respect to all MegaPort, IPTV products and fiber optics receivers, transmitters, couplers and
integrated receivers/distribution amplifiers (including TRAILBLAZER™, RETRO-LINX™ and TWIN STAR™ products) as well as for
VideoCipher® & DigiCipher® satellite receivers, and (iii) for a period of three (3) years from the date of original purchase, with
respect to all other BT products. Notwithstanding the foregoing, in some cases, the warranty on certain proprietary sub-assembly
modules manufactured by third party vendors and contained in BT products and on certain private-label products manufactured
by third parties for resale by BT are of shorter duration or otherwise more limited than the standard BT limited warranty. In such
cases, BT’s warranty with respect to such third party proprietary sub-assembly modules and private-label products will be limited
to the duration and other terms of such third party vendor’s warranty. In addition, certain products, that are not manufactured
but are resold by BT, carry the original OEM warranty for that product. The limited warranty set forth in this paragraph does not
apply to any product sold by BT, which at the time of sale constituted a Closeout Product.
BT will at its sole option, either repair or replace (with a new or factory reconditioned product, as BT may determine) any product
sold by BT which at the time of sale constituted a refurbished or closeout items (“Refurbished Product” and “Closeout Product”),
which proves to be defective in materials or workmanship or fails to meet the specifications which are in effect on the date of
shipment or such other specifications as may have been expressly agreed upon in writing, for a period of ninety (90) days from
the date of original purchase. Notwithstanding the foregoing, in some cases, the warranty on third party software and on certain
proprietary sub-assembly modules manufactured by third party vendors and contained in BT products and on certain private-
label products manufactured by third parties for resale by BT are of shorter duration or otherwise more limited than the BT limited
warranty for Closeout Products. In such cases, BT’s warranty for Closeout Products constituting such third party software, third
party proprietary sub-assembly modules and private-label products will be limited to the duration and other terms of such third
party vendor’s warranty. In addition, notwithstanding the foregoing, (i) certain Closeout Products that are not manufactured (but
are resold) by BT, carry the original OEM warranty for such products, which may be longer or shorter than the BT limited warranty
for Refurbished or Closeout Products. All sales of Refurbished or Closeout Products are final.
To obtain service under this warranty, the defective product, together with a copy of the sales receipt or other satisfactory proof
of purchase and a brief description of the defect, must be shipped freight prepaid to: Blonder Tongue Laboratories, Inc., One Jake
Brown Road, Old Bridge, New Jersey 08857.
This warranty does not cover damage resulting from (i) use or installation other than in strict accordance with manufacturer’s
written instructions, (ii) disassembly or repair by someone other than the manufacturer or a manufacturer-authorized repair
center, (iii) misuse, misapplication or abuse, (iv) alteration, (v) lack of reasonable care or (vi) wind, ice, snow, rain, lightning, or
any other weather conditions or acts of God.
OTHER THAN THE WARRANTIES SET FORTH ABOVE, BT MAKES NO OTHER WARRANTIES OR REPRESENTA-
TIONS OF ANY KIND, EXPRESS OR IMPLIED, AS TO THE CONDITION, DESCRIPTION, FITNESS FOR A PARTIC-
ULAR PURPOSE, MERCHANTABILITY OR AS TO ANY OTHER MATTER, AND SUCH WARRANTIES SUPERSEDE
ANY ORAL OR WRITTEN WARRANTIES OR REPRESENTATIONS MADE OR IMPLIED BY BT OR BY ANY OF BT’S
EMPLOYEES OR REPRESENTATIVES, OR IN ANY OF BT’S BROCHURES, MANUALS, CATALOGS, LITERATURE
OR OTHER MATERIALS. IN ALL CASES, BUYER’S SOLE AND EXCLUSIVE REMEDY AND BT’S SOLE OBLIGA-
TION FOR ANY BREACH OF THE WARRANTIES CONTAINED HEREIN SHALL BE LIMITED TO THE REPAIR OR
REPLACEMENT OF THE DEFECTIVE PRODUCT F.O.B. SHIPPING POINT, AS BT IN ITS SOLE DISCRETION SHALL
DETERMINE. BT SHALL IN NO EVENT AND UNDER NO CIRCUMSTANCES BE LIABLE OR RESPONSIBLE FOR
ANY CONSEQUENTIAL, INDIRECT, INCIDENTAL, PUNITIVE, DIRECT OR SPECIAL DAMAGES BASED UPON
BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT TORT LIABILITY OR OTHERWISE OR
ANY OTHER LEGAL THEORY ARISING DIRECTLY OR INDIRECTLY FROM THE SALE, USE, INSTALLATION OR
FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT.
All claims for shortages, defects and non-conforming goods must be made by Buyer in writing within five (5) days of receipt of
merchandise, which writing shall state with particularity all material facts, concerning the claim then known to Buyer. Upon any
such complaint, Buyer shall hold the goods complained of intact and duly protected, for a period of up to sixty (60) days. Upon
the request of BT, Buyer shall ship such allegedly nonconforming or defective goods, freight prepaid to BT for examination by
BT’s inspection department and verification of the defect. BT, at its option, will either repair, replace or issue a credit for products
determined to be defective. BT’s liability and responsibility for defective products is specifically limited to the defective item or to
credit towards the original billing. All such replacements by BT shall be made free of charge f.o.b. the delivery point called for in
the original order. Products for which replacement has been made under the provisions of this clause shall become the property
of BT. Under no circumstances are products to be returned to BT without BT’s prior written authorization. BT reserves the right
to scrap any unauthorized returns on a no-credit basis. Any actions for breach of this contract must be commenced by Buyer
within thirteen (13) months after the cause of action has accrued. A copy of BT’s standard terms and conditions of sale, including
the limited warranty, is available from BT upon request. Copies of the limited warranties covering third party proprietary sub-
assembly modules and private label products manufactured by third parties are also available from BT on request. VideoCipher®
& DigiCipher® are registered trademarks of Motorola Corp.
Blonder Tongue Laboratories, Inc.
Limited Warranty
Blonder Tongue Laboratories, Inc. (BT) will at its sole option, either repair or replace (with a new or factory reconditioned product, as BT may
determine) any product manufactured by BT which proves to be defective in materials or workmanship or fails to meet the specifications which are
in effect on the date of shipment or such other specifications as may have been expressly agreed upon in writing (i) for a period of one (1) year from
the date of original purchase (or such shorter period of time as may be set forth in the license agreement specific to the particular software being
licensed), with respect to iCentral™ (hardware and software) and all other software products (including embedded software) licensed from BT, (ii) )
for a period of one (1) year from the date of original purchase, with respect to all MegaPort™, IPTV products, and fiber optics receivers, transmitters,
couplers and integrated receiver/distribution amplifiers (including TRAILBLAZER™, RETRO-LINX™ and TWIN STAR™ products) as well as for
DigiCipher ® satellite receivers, and (iii) for a period of three (3) years from the date of original purchase, with respect to all other BT products.
Notwithstanding the foregoing, in some cases, the warranty on certain proprietary sub-assembly modules manufactured by third-party vendors and
contained in BT products and on certain private–label products manufactured by third-parties for resale by BT are of shorter duration or otherwise
more limited than the standard BT limited warranty. In such cases, BT's warranty with respect to such third-party proprietary sub-assembly modules
and private-label products will be limited to the duration and other terms of such third-party vendor's warranty. In addition, certain products, that are
not manufactured but are resold by BT, carry the original OEM warranty for such products. The limited warranty set forth in this paragraph does not
apply to any product sold by BT, which at the time of sale constituted a Refurbished/Closeout Product.
(b) BT will at its sole option, either repair or replace (with a new or factory-reconditioned product, as BT may determine) any product sold by BT
which at the time of sale constituted a refurbished or closeout item (“Refurbished/Closeout Product”), which proves to be defective in materials or
workmanship or fails to meet the specifications which are in effect on the date of shipment or such other specifications as may have been expressly
agreed upon in writing, for a period of ninety (90) days from the date of original purchase. Notwithstanding the foregoing, in some cases the
warranty on third party software and on certain proprietary sub-assembly modules manufactured by third-party vendors and contained in BT products
and on certain private–label products manufactured by third-parties for resale by BT are of shorter duration or otherwise more limited than the BT
limited warranty for Refurbished/Closeout Products. In such cases, BT's warranty for Refurbished/Closeout Products constituting such third party
software, third-party proprietary sub-assembly modules and private-label products will be limited to the duration and other terms of such third-party
vendor's warranty. In addition, notwithstanding the foregoing, (i) certain Refurbished/Closeout Products that are not manufactured (but are resold)
by BT, carry the original OEM warranty for such products, which may be longer or shorter than the BT limited warranty for Refurbished/Closeout
Products. All sales of Refurbished/Closeout Products are final.
To obtain service under this warranty, the defective product, together with a copy of the sales receipt or other satisfactory proof of purchase and a
brief description of the defect, must be shipped freight prepaid to: Blonder Tongue Laboratories, Inc., One Jake Brown Road, Old Bridge, New
Jersey 08857.
This warranty does not cover damage resulting from (i) use or installation other than in strict accordance with manufacturer's written instructions, (ii)
disassembly or repair by someone other than the manufacturer or a manufacturer-authorized repair center, (iii) misuse, misapplication or abuse, (iv)
alteration, (v) lack of reasonable care or (vi) wind, ice, snow, rain, lightning, or any other weather conditions or acts of God.
OTHER THAN THE WARRANTIES SET FORTH ABOVE, BT MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF
ANY KIND, EXPRESS OR IMPLIED, AS TO THE CONDITION, DESCRIPTION, FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR AS TO ANY OTHER MATTER, AND SUCH WARRANTIES SUPERSEDE ANY ORAL OR WRITTEN
WARRANTIES OR REPRESENTATIONS MADE OR IMPLIED BY BT OR BY ANY OF BT’S EMPLOYEES OR
REPRESENTATIVES, OR IN ANY OF BT’S BROCHURES MANUALS, CATALOGS, LITERATURE OR OTHER MATERIALS. IN
ALL CASES, BUYER’S SOLE AND EXCLUSIVE REMEDY AND BT’S SOLE OBLIGATION FOR ANY BREACH OF THE
WARRANTIES CONTAINED HEREIN SHALL BE LIMITED TO THE REPAIR OR REPLACEMENT OF THE DEFECTIVE
PRODUCT F.O.B. SHIPPING POINT, AS BT IN ITS SOLE DISCRETION SHALL DETERMINE. BT SHALL IN NO EVENT AND
UNDER NO CIRCUMSTANCES BE LIABLE OR RESPONSIBLE FOR ANY CONSEQUENTIAL, INDIRECT, INCIDENTAL,
PUNITIVE, DIRECT OR SPECIAL DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE,
STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL THEORY, ARISING DIRECTLY OR INDIRECTLY FROM
THE SALE, USE, INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM BT.
All claims for shortages, defects, and non-conforming goods must be made by the customer in writing within five (5) days of receipt of merchandise,
which writing shall state with particularity all material facts concerning the claim then known to the customer. Upon any such claim, the customer
shall hold the goods complained of intact and duly protected, for a period of up to sixty (60) days. Upon the request of BT, the customer shall ship
such allegedly non-conforming or defective goods, freight prepaid to BT for examination by BT's inspection department and verification of the
defect. BT, at its option, will either repair, replace or issue a credit for products determined to be defective. BT's liability and responsibility for
defective products is specifically limited to the defective item or to credit towards the original billing. All such replacements by BT shall be made
free of charge f.o.b. the delivery point called for in the original order. Products for which replacement has been made under the provisions of this
clause shall become the property of BT. Under no circumstances are products to be returned to BT without BT's prior written authorization. BT
reserves the right to scrap any unauthorized returns on a no-credit basis. Any actions for breach of a contract of sale between BT and a customer must
be commenced by the customer within thirteen (13) months after the cause of action has accrued. A copy of BT's standard terms and conditions of
sale, including the limited warranty, is available from BT upon request. Copies of the limited warranties covering third-party proprietary sub-
assembly modules and private-label products manufactured by third-parties are also available from BT on request. DigiCipher ® is a registered
trademark of Motorola Corp. (Rev 0509)
Seller will at its sole option, either repair or replace (with a new or factory reconditioned product, as Seller may determine) any product manufactured or sold (or in
the case of software, licensed) by Seller which is defective in materials or workmanship or fails to meet the applicable specifications that are in effect on the date of
shipment or such other specifications as may have been expressly agreed upon in writing: (i) for a period of one (1) year from the date of original purchase for all
stock hardware products (other than those specifically referenced herein below having a shorter warranty period); (ii) for a period of one (1) year from the date of
original purchase, with respect to all MegaPort™, IPTV products, test equipment and fiber optics receivers, transmitters, couplers and integrated receiver/distribution
amplifiers; (iii) for a period of one (1) year from the date of original purchase (or such shorter period of time as may be set forth in the license agreement specific to
the particular software being licensed from Seller) with respect to all software products licensed from Seller (other than Core Product Software) that is (a) developed
for a specific function or application, (b) complimentary to and does not function without the Core Product Software, and (c) listed with a specific model number and
stock number in Seller’s Price List (“Non-Core Software”); (iv) for a period of ninety (90) days from the date of original purchase, with respect to non-serialized
products and accessories, such as parts, sub-assemblies, splitters and all other products sold by Seller (other than Core Product Software and Refurbished/Closeout
Products) not otherwise referred to in clauses (i) through (iii) above. The warranty period for computer programs in machine-readable form included in a hardware
product, which are essential for the functionality thereof as specifically stated in the published product specifications (“Core Product Software”) will be coincident
with the warranty period of the applicable hardware product within which such Core Product Software is installed.
Software patches, bug fixes, updates or workarounds do not extend the original warranty period of any Core Product Software or Non-Core Software.
Notwithstanding anything herein to the contrary,
(i) Seller’s sole obligation for software that when properly installed and used does not substantially conform to the published specifications in effect when the
software is first shipped by Seller, is to use commercially reasonable efforts to correct any reproducible material non-conformity (as determined by Seller in its sole
discretion) by providing the customer with: (a) telephone or e-mail access to report non-conformance so that Seller can verify reproducibility, (b) a software patch or
bug fix, if available or a workaround to bypass the issue if available, and (c) where applicable, replacement or damaged or defective external media, such as CD-ROM
disk, on which the software was originally delivered;
(ii) Seller does not warrant that the use of any software will be uninterrupted, error-free, free of security vulnerabilities or that the software will meet the customer’s
particular requirements; and the customer’s sole and exclusive remedy for breach of this warranty is, at Seller’s option, to receive (a) suitably modified software, or
part thereof, or (b) comparable replacement software or part thereof;
(iii) Seller retains all right, title and interest in and to and ownership of all software (including all Core Product Software and Non-Core Software) including any and all
enhancements, modifications and updates to the same; and
(iv) in some cases, the warranty on certain proprietary sub-assembly modules manufactured by third-party vendors and contained in Seller’s products, third party
software installed in certain of Seller’s products, and on certain private–label products manufactured by third-parties for resale by Seller, will be of shorter duration
or otherwise more limited than the standard Seller limited warranty. In such cases, Seller's warranty with respect to such third-party proprietary sub-assembly
modules, third-party software and private-label products will be limited to the duration and other terms of such third-party vendor's warranty, if any. In addition,
certain products, that are not manufactured by Seller, but are resold by Seller, may carry the original OEM warranty for such products, if any. The limited warranty
set forth above does not apply to any product sold by Seller, which at the time of sale constituted a Refurbished/Closeout Product, the limited warranty for which is
provided in the following paragraph.
Seller will at its sole option, either repair or replace (with a new or factory-reconditioned product, as Seller may determine) any product sold by Seller which at the
time of sale constituted a refurbished or closeout item (“Refurbished/Closeout Product”), which is defective in materials or workmanship or fails to meet the
applicable specifications that are in effect on the date of shipment of that product or fails to meet such other specifications as may have been expressly agreed upon
in writing between the parties, for a period of ninety (90) days from the date of original purchase. Notwithstanding the foregoing, in some cases the warranty on
certain proprietary sub-assembly modules manufactured by third-party vendors and contained in Seller products, third party software installed in certain of Seller’s
products, and on certain private–label products manufactured by third-parties for resale by Seller will be of shorter duration or otherwise more limited than Seller
limited warranty for Refurbished/Closeout Products. In such cases, Seller's warranty for Refurbished/Closeout Products constituting such third party proprietary
sub-assembly modules, third party software, and private-label products will be limited to the duration and other terms of such third-party vendor's warranty, if any.
In addition, notwithstanding the foregoing, (i) certain Refurbished/Closeout Products that are not manufactured (but are resold) by Seller, may carry the original OEM
warranty for such products, if any, which may be longer or shorter than Seller’s limited warranty for Refurbished/Closeout Products. All sales of
Refurbished/Closeout Products are final.
To obtain service under this warranty, the defective product, together with a copy of the sales receipt, serial number if applicable, or other satisfactory proof of
purchase and a brief description of the defect, must be shipped freight prepaid to Seller at the following address: One Jake Brown Road, Old Bridge, New Jersey
08857.
This warranty does not cover failure of performance or damage resulting from (i) use or installation other than in strict accordance with manufacturer's written
instructions, (ii) disassembly or repair by someone other than the manufacturer or a manufacturer-authorized repair center, (iii) misuse, misapplication or abuse, (iv)
alteration, (v) exposure to unusual physical or electrical stress, abuse or accident or forces or exposure beyond normal use within specified operational or
environmental parameters set forth in applicable product specifications, (vi) lack of reasonable care or (vii) wind, ice, snow, rain, lightning, or any other weather
conditions or acts of God.
OTHER THAN THE WARRANTIES SET FORTH ABOVE, SELLER MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND, EXPRESS OR IMPLIED, AS
TO THE CONDITION, DESCRIPTION, FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR AS TO ANY OTHER MATTER, AND SUCH WARRANTIES
SET FORTH ABOVE SUPERSEDE ANY ORAL OR WRITTEN WARRANTIES OR REPRESENTATIONS MADE OR IMPLIED BY SELLER OR BY ANY OF SELLER’S
EMPLOYEES OR REPRESENTATIVES, OR IN ANY OF SELLER’S BROCHURES MANUALS, CATALOGS, LITERATURE OR OTHER MATERIALS. IN ALL CASES, BUYER’S
SOLE AND EXCLUSIVE REMEDY AND SELLER’S SOLE OBLIGATION FOR ANY BREACH OF THE WARRANTIES CONTAINED HEREIN SHALL BE LIMITED TO THE
REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT F.O.B. SHIPPING POINT, AS SELLER IN ITS SOLE DISCRETION SHALL DETERMINE. SELLER SHALL IN
NO EVENT AND UNDER NO CIRCUMSTANCES BE LIABLE OR RESPONSIBLE FOR ANY CONSEQUENTIAL, INDIRECT, INCIDENTAL, PUNITIVE, DIRECT OR SPECIAL
DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, STRICT TORT LIABILITY OR OTHERWISE OR ANY OTHER LEGAL
THEORY, ARISING DIRECTLY OR INDIRECTLY FROM THE SALE, USE, INSTALLATION OR FAILURE OF ANY PRODUCT ACQUIRED BY BUYER FROM SELLER.
All claims for shortages, defects, and non-conforming goods must be made by the customer in writing within five (5) days of receipt of merchandise, which writing
shall state with particularity all material facts concerning the claim then known to the customer. Upon any such claim, the customer shall hold the goods complained
of intact and duly protected, for a period of up to sixty (60) days. Upon the request of Seller, the customer shall ship such allegedly non-conforming or defective
goods, freight prepaid to Seller for examination by Seller's inspection department and verification of the defect. Seller, at its option, will either repair, replace or issue
a credit for products determined to be defective. Seller's liability and responsibility for defective products is specifically limited to the defective item or to credit
towards the original billing. All such replacements by Seller shall be made free of charge f.o.b. the delivery point called for in the original order. Products for which
replacement has been made under the provisions of this clause shall become the property of Seller. Under no circumstances are products to be returned to Seller
without Seller's prior written authorization. Seller reserves the right to scrap any unauthorized returns on a no-credit basis. Any actions for breach of a contract of
sale between Seller and a customer must be commenced by the customer within thirteen (13) months after the cause of action has accrued. A copy of Seller's
standard terms and conditions of sale, including the limited warranty, is available from Seller upon request. Copies of the limited warranties covering third-party
proprietary sub-assembly modules and private-label products manufactured by third-parties may also be available from Seller on request. (Rev 0713)
Limited Warranty