Ametek UPS-I000-OL Operation & User’s Manual

File Specifications

Brand: Ametek
Category: UPS
Model: UPS-I000-OL (Operation & User’s Manual), prHpzaPdoMKjE
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 44 pages

Download PDF

Download Ametek UPS-I000-OL Manual (44 pages)

Read Online:

Read the Ametek UPS-I000-OL Operation & User’s Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

Table of Contents

1. Introduction 1 1.1 Technical Support 1 1.2 FCC Compliance 1 1.3 Safety Compliance 1 1.4 About This Manual 1 1.5 Safety 2 1.5.1 Safety Intended Use 2 1.5.2 General Warnings 2 1.5.3 Safety Notices 2 1.5.4 Battery Safety 4 1.5.5 Repacking of Unit 4 2. Overview 5 2.1 UPS Devices and Batteries 5 2.2 Packing List 5 2.3 Storage 5 2.4 Recharging the UPS During Storage 6 2.5 Environmental Conditions 6 2.6 Floor Loading 6 2.7 Ventilation 6 2.8 Rear Panel View 7 2.8.1 Model: UPS-1000-OL 7 2.8.2 Model: UPS-2000-OL 7 2.8.3 Model: UPS-3000-OL 7 2.9 LCD Display .......................... ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 10

3. Installation The UPS and external battery pack are designed to be rack-mounted in four post frames or to be floor standing in a tower configuration. 3.1 Tower Installation ATTENTION: Use all supplied mounting hardware on each UPS and extended battery pack. A. To install standalone, refer to the figure directly below: Assemble two feet as one tower stand. Align the two stands. Put the UPS module in the stands. B. To install a UPS module and one extended battery pack, r ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 32

10 APPENDIX A: SPECIFICATIONS 10.1 SURGEX UPS (100 - 120 Volt UPS’s) Specifications SurgeX UPS 1000 VA Low Voltage Model UPS-1000-OL Type SurgeX Power Rating 1000 VA / 900 W Topology On-Line Double Conversion Heat Dissipation (BTU/Hour) 520 at 100% Load Input Voltage (Nominal) Range 100-120 VAC 90-150 VAC Input Frequency 50/60 Hz ±4 (Auto Sense on Start-Up) Input Power Factor >0.95 Input Current THD <9.0% Efficiency >84.0% Output Voltage 120 VAC (Default) 100/110/115 ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 17

4.2.3 Output Frequency Setting (Item 03) Interface Setting You may set the initial frequency on battery mode: 50: output frequency is 50Hz 60: output frequency is 60Hz If converter mode is enabled, the following output frequency can be chosen: 50: output frequency is 50Hz 60: output frequency is 60Hz 4.2.4 Bypass Mode Enable /Disable when the UPS is off (Item 06) Interface Setting ENA: Bypass mode is enabled when the UPS is turned off. When the UPS is first plugged in, i ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 23

Pin 1 and Pin 2 shown in closed status. 7. Emergency Power Off (EPO) Disable and Enable the EPO Function Keep Pin 1 and Pin 2 closed (shorted) for UPS normal operation. To activate the EPO function, remove the wire between Pin 1 and Pin 2. 8. Maintenance 8.1 Cleaning 1. Do not use scouring powder or plastic dissolving solutions to clean the UPS. 2. Do not allow liquid to get inside the UPS. 3. Make sure that the air vents on the UPS are not obstructed. Remove dust from t ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 1

1. Introduction Thank you for selecting this uninterruptible power supply (UPS). SurgeX offers the most reliable protection from the harmful effects of electrical line disturbances for your computing and communications equipment. 1.1 Technical Support Tel: (800) 645-9721 Email: [email protected] Please check with technical support before attempting to repair or return any UPS product. If a UPS needs repair or replacement, technical support will issue a return material ...

© 2017 AMETEK Electronic Systems Protection / Technical Support: 1-800-645-9721 / espsurgex.com 9

2.10 LCD: Display and Functional Description Display Function Backup time information Indicates the backup time. Indicates the backup time. H: hours, M: minutes Warning & Fault information Indicates that a warning and/or fault has occurred. Indicates the warning and fault codes. The codes are listed in sections 9.4 and 9.5. Setting Operation Indicates the setting information. Input/Output & Battery information Indicates the input/output voltage, input/output frequency, an ...

Ametek UPS-I000-OL user guide recommended for: IUPS-401, Surgex UPS-17202-53R, POWER PLUS, ABCE702-11R, PM Series.

⚠️ Download Safety

The UPS Operation & user’s manual (44 pages) is completely safe to download (last scan date: 12/04/2026).

Related PDF Instructions for Ametek UPS-I000-OL:

UPS Equipment: Frequently Requested

Have some Questions about Ametek UPS-I000-OL Device?

Get valuable and actionable advices from other Ametek UPS-I000-OL device users. Describe your problem or question, regarding the using of UPS-I000-OL, in as much detail as possible, and other users will be able to answer you.