Analytic Systems PWS1005W Installation & Operation Manual

Specifications

Brand: Analytic Systems
Category: Power Supply
Model: PWS1005W (Installation & Operation Manual)
File Type: PDF
File Size: —
Pages: 16

Read Online

Read the Analytic Systems PWS1005W Installation & Operation Manual online using the built-in PDF viewer.

Text of the manual

8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA)

www.analyticsystems.com An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters PWS1005W POWER SUPPLY

IMPORTANT SAFETY INSTRUCTIONS

MEDICAL EQUIPMENT NOTICE Analytic Systems does not recommend the use of their products in life support applications where failure or malfunction of this product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Analytic Systems does not recommend the use of any of its products in direct patient care. Examples of devices considered to be life support devices are neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), auto-transfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants, anesthesia ventilators, and infusion pumps as well as any other devices designated as “critical” by the U.S. FDA DANGER: Never alter the AC power cord or plug provided. If it will not fit the output, use an approved adapter or have the proper AC power cord installed by a qualified electrician. Improper installation can result in the risk of electric shock. WARNING: Do not use this power supply to charge a battery. It does not have the necessary circuitry on the output to prevent it from overcharging the battery. SAVE THESE INSTRUCTIONS — This manual contains important safety and operating instructions for the power supply. POWER SUPPLY PRECAUTIONS 1. Do not expose power supply to rain or snow unless it is a sealed model. 2. Use of an attachment not recommended or sold by the manufacturer may result in risk of electric shock, fire, or injury to persons. 3. Do not disassemble power supply; return it to the manufacturer or an authorized service center when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. Voltages in excess of 350 volts are present inside the unit any time it is plugged into an AC outlet, even if it is switched OFF. 4. To reduce risk of electric shock, unplug the unit from the AC pbefore attempting any maintenance or cleaning. Switching the unit OFF will not reduce this risk. 5. To reduce risk of electric shock, the power switch must be OFF when connecting or disconnecting the DC power output(s). 6. The AC outlet that this unit is plugged into must be properly installed and grounded in accordance with all local codes and ordinances.

TABLE OF CONTENTS

• Front Cover, Product Photo and Title • Product Warnings and Advisories • Table of Contents • Introduction • Box Contents • Main Parts • Operation • Output Fuse Replacement • Installation • Troubleshooting • Product Options • Specifications • Warranty Copyright (2005-2020) Analytic Systems Ware (1993) Ltd. Revised - Feb 24, 2020

The PWS1005W power supply provides up to 1000 watts of precision power to a 12, 24, 32, 36,

48, or 72 (Rail) VDC electrical system from a 110 or 220 VAC source. Designed for service in the most unforgiving environments, the PWS1005W has an operational temperature range spanning -40°C to +55°C. The unit’s rugged chassis is built to be water and dust resistant to meet the IP66 rating, while internal components are sealed with additional RTV silicone for maximum vibration and shock protection. Internally, the recently updated single board design incorporates time-tested switch-mode technology for unmatched efficiency and ultra-quiet operation. New circuit innovations reduce output ripple to levels previously only available from bulky, inefficient linear power supplies. In addition, multiple stages of filtering on the input and output reduce radiated and conducted noise to very low levels. Built for the safest operation possible, reliability features built into the PWS1005W include an input fuse, thermal shutdown, under voltage shutdown, and short circuit shutdown, all with automatic recovery. Devices connected to the power supply are protected by an output over voltage crowbar circuit and output current limiting. All these alarm states and the unit’s operating condition are easily monitored on the bright and easy-to-read LED Indicator display. The box you have received should contain the following: • One PWS1005W • This User Guide • One Warranty Card If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement. Box Contents

DC Output Connection:

8AWG TEW-type stranded wire, bare copper leads (Positive: Red and Negative: Black) encased in a sealcon gland 2. LED Operational Indicators 3. Power Switch 4. AC Input Connection: 3.05m /10.00ft P3x14AWG power cord ending in a NEMA 5-15;125VAC plug encased in a sealcon gland 5. Input Fuse: MDA 25 Amp 4 2 1 Main Parts 3 Front Panel 5

This unit is designed for simple operation. Before operating the unit, it must be properly

installed and connected to the power source and load. See Installation for more details. TO TURN THE UNIT ON: 1. Move the Power Switch to the ON position. 2. The alarm buzzer will sound briefly and the POWER LED will begin glowing green indicating the power supply is supplying the load. TO TURN THE UNIT OFF: 1. Move the Power Switch to the OFF position and wait for the POWER LED to stop glowing. 2. Once all the LEDs are off, it is safe to disconnect the load and power source from the power supply. 3. Move the Power Switch back to the ON position while disconnected from the power source to discharge the internal capacitors. 4. After 30 seconds, move the Power Switch back to the OFF position. The unit can now be safely serviced or put into storage.

Mount the unit in a WELL VENTILATED location. Allow at

least 1 inch (2.54 cm) of clearance surrounding the unit for adequate cooling. The PWS1005W is designed to meet IP66 rating,and is resistant to water spray from any direction. These units can be mounted in wet locations but are not suitable for submersion. WARNING: TO PREVENT THE RISK OF ELECTRIC SHOCK, NEVER DISCONNECT THE INPUT OR OUTPUT WHILE THE UNIT IS ENERGIZED. Installation DC OUTPUT CONNECTION This unit is equipped with two 8AWG TEW-type stranded leads terminating bare copper. The wiring for this connection can be found on the units front panel label and is as follows: Wire color Polarity Black AC Live/Hot Gray AC Neutral Green/Yellow AC Ground Wire color Polarity Black DC Output Negative Red DC Output Positive This unit’s maximum continuous output current is 40A. When connecting devices to the power supply, ensure total connected load is less than 40A and that the wiring used is rated for this current. *This unit shown with the Portable Option AC INPUT CONNECTION This unit is equipped with a 3.05m/10.00ft 3x14AWG power cord ending in a NEMA 5-15 compatible plug suitable for connection to any typical North American AC Mains outlet. If you need to hard-wire this connection, cut the plug off the cord and strip the wires inside, the wiring for this cord as follows: CAUTION: DO NOT CONNECT THE LOAD IN THE REVERSE POLARITY!! This will activate the reverse connection protection which will blow the output fuses inside the unit in order to protect the device.The unit will be inoperable until these fuses have been replaced.

Output Fuse Replacement

The power supply is protected from damage by reverse polarity connection by output fuses. If the load is connected to the unit in the wrong polarity, the output fuse(s) will blow to protect the power supply. Afterwards, the fuses must be replaced for normal unit operation. See the specifications section for rating and make fuses. All the output fuses must be replaced as they operate in parallel to add up to the full output current capability of the power supply. CAUTION: BEFORE REPLACING THE FUSES, DISCONNECT OR TURN OFF THE AC POWER TO THE POWER SUPPLY AND DISCONNECT IT FROM THE LOAD. When connecting the load to the unit a small arc can form between the connectors. To ensure spark-free connections, make connections only when the power switch is OFF. TO REPLACE THE FUSES 1. Loosen and remove the ten (10) screws holding the front panel to the unit chassis. 2. Gently wiggle the front panel to unplug it from the main circuit board. The output fuses are mounted in fuse holders close to the output cable or connector. 3. Remove and replace them all with the same style and current rating. 4. Gently push the front panel connector back onto the main circuit board, ensuring that any O-Ring or gasket remains properly seated. This is particularly important for W and Y models to ensure a water-tight seal! 5. Carefully re-insert all the front panel screws loosely, making sure non are cross threaded. Once all screws are started, tighten them in sequence. These screws are made from corrosion resistant stainless steel and are softer that regular steel screws, so take care to not over- tighten. 6. Reconnect AC power to the unit and ensure that it turns ON. Carefully recheck the polarity of the output connections and then reconnect the load to the power supply. Normal operation should resume immediately. Pictured: Front panel circuit board. Output fuse location indicated by red circle.

This unit is fitted with 5 LED indicators and an alarm buzzer to display and diagnose any

malfunctions. In the event of a malfunction, the unit will sound the buzzer to alert you before shutting itself down. You should then immediately check which LEDs are glowing to determine the cause of the alarm. LED Indicator Meaning OVERTEMP The power supply’s internal temperature is too high for safe operation. Fix: The power supply will shut down until it cools sufficiently. If this happens repeatedly, you may need to remount the power supply for better ventilation and cooling. Disconnecting some connected devices to reduce the load on the power supply may also help. OVERLOAD The load is drawing too much current from the power supply. Fix: The unit is operating above its peak output current for too long of a time. Disconnect some of the connected devices to reduce the load on the power supply. Check that the combined load of each device connected to the power supply does not exceed the unit’s continuous output current. See Specifications for more details. UNDER V. INPUT The AC input voltage is too low for proper operation. Fix: Check that the AC power source is a proper voltage rating for the power supply. Check that the input wiring and connectors are free of damage and corrosion. If all the above is in proper working order, the cause is likely an internal component failure and the unit must be returned to an authorized service center for repair. UNDER V. OUTPUT The power supply’s output voltage is too low for proper operation. Fix: The output current may be exceeding the unit’s maximum rating causing the output voltage to drop to maintain the current at that level. Check that the current is not excessive and the OVERLOAD LED isn’t glowing. If it is, reduce the load on the power supply. Check that the output wiring and connectors are free of damage and corrosion. If all the above is in proper working order, the cause is likely an internal component failure and the unit must be returned to an authorized service center for repair. Troubleshooting

In normal operation, the DC

output supplies the load and an internal 1 amp trickle charger. The trickle charger maintains the connected battery at full charge until needed. The current flow in this operating condition indicated in RED. In the event of power failure, the load instantly begins drawing from the battery as power source, running until either the battery is fully discharged or the unit goes into low voltage shutdown. The configuration of the schottky diodes on the battery output line prevents current from backfeeding into the unit. The current flow in this operating condition is indicated in BLUE. Battery Backup Option NOTE: The diagrams below show the voltages for a 24V system, but this option is available for every standard output voltage model. 27.2V 1A Charger In Out Main PCB DC Output 28V Batt - Batt + OP - OP + 24V Battery To Load The Battery Backup Option allows you to connect a battery to the output of your unit to serve as a backup power source in the event of power failure. The Battery Backup circuit is designed so the diodes are reversed biased in normal operation and forward biased in event of power failure. Basically, whichever source (the battery or the DC Output) has the higher voltage will take precedence in supplying power to the load. To set up the Battery Backup: 1. Connect the Load to the output terminals labelled OP+ and OP- 2. Connect the Battery to the output terminals labelled Batt+ and Batt- Normal Operation WARNING: Do not connect a battery to the unit’s output unless it has the Battery Backup Option. This will cause serious damage to the unit and is not covered by the Warranty. 27.2V 1A Charger In Out Main PCB DC Output 0V Batt - Batt + OP - OP + To Load 24V Battery Output Failure

Load Sharing Option

The Load Sharing Option allows you to connect two or more units in parallel, allowing them to share in supplying current to the load(s). Connecting units together this way has many advantages, it reduces stress on each individual power supply and in addition, the load can draw greater current than from a single unit. Units built with this option are equipped with special output isolation diodes on the output terminals. You can check if your unit has these diodes by using an ohmmeter to measure the resistance between the two positive output terminals. • If the diodes are present, the terminals will measure as not connected. • If the diodes are NOT present, the terminals will measure as a short circuit. To set up load sharing: 1. Connect a length of #12 AWG RED wire to each positive output terminal of each unit. 2. Connect all the positive wires to a distribution bus or join them together at a common point. 3. Connect the distribution bus or common point to the load using an appropriate gauge of wire for the total output current capability of all the supplies running in parallel. 4. Repeat Steps 1-3 for the negative output terminals using the same gauges of BLACK wire. 5. The units should now load share. 6. You can confirm this by checking the output terminals using an ammeter or or by checking the integrated voltmeter/ammeter if the unit is built with that option. Unit #1 Unit #2 TIP: The Output Voltage Adjust can also be used to adjust the output current. A slight difference in the output current between the units is negligible. However, if this isn’t the case, the current can be adjusted using the Output Voltage Adjust potentiometer. Increasing the output voltage decreases the output current and vice versa.

110 and 220 VAC (Auto-switching)

Actual Voltage 90 - 133 VAC and 180 - 264 VAC Current 13.1 A (Maximum @ 90 VAC in) Fuse MDA 25 Amp Input Frequency 49 - 405 Hz Noise on Input < 50 mV Peak to Peak Inrush Current < 13A @ 264 VAC In from fully discharged Output Nominal Voltage 12 VDC 24 VDC 32 VDC 36 VDC 48 VDC 72 (Rail) VDC Actual Voltage 13.6 VDC 27.2 VDC 36.3 VDC 40.8 VDC 54.4 VDC 72.5 VDC Overvoltage Protection Crowbar 17.0 ±0.5V 34.0 ±1.0V 45.0 ±1.5V 51.0 ±1.5V 68.0 ±2.0V 90.0 ±2.5V Continuous Amps 80 A 40 A 30 A 27A 20 A 15 A Peak Amps 120 A 66 A 50 A 45A 33 A 24 A Fuses 3x ATM30 2x ATM25 2x ATM20 2x 20A Bel 0697H9200 2x 15A Bel 0697H9150 1x 20A Bel 0697H9200 Output Voltage Adjustment ± 1.0 V Duty Cycle Continuous: 100% for 24 hours per day Peak: 20% for ten minutes per hour maximum Transient Response <1V for 50% Surge Ripple and Noise <50 mV Efficiency >85% @ Maximum Output Noise on Output < 50 mV Regulation (Line and Load) <+/- 0.5%

18.0 inches / 45.7 cm

Width 8.2 in / 20.8 cm Height 3.8 in / 9.7 cm Clearance 1.0 in / 2.5 cm all around Weight 20.0 lb / 9.9 kg Material and Fastenings Black anodized extruded aluminum chassis and bottom plate. Black anodized billet machined aluminum end plages with O-ring seals. Fasteners 18-8 Stainless steel Input Connection 2x color-coded flying input leads encased in a watertight Sealon gland Output Connection 3.0 m / 10.0ft 3xAWG14 power cord with NEMA 5-15 compatible plug General Operating Temperature -40°C to +55°C @ maximum output. Derate Linearly 2.5% per °C from 55°C Storage Temperature -40°C to +100°C Humidity 0 - 95%Relative Humidity (non-condensing) and standard conformal coating Ingress Protection IP66 (Dust-proof and protected from high pressure water jets) Audible Noise None, 0 db @ 3 ft Isolation Input-Case, Input-Output and Output-Case: 1500 VDC Typical Service Life >10 Years (87,600 hours) Warranty Three Years Parts and Labor Safety Built to meet CSA C22.2 No.107.1 and UL 458 * Specifications subjects to change without notice. Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 8128 River Way Delta, B.C. V4G 1K5 Canada p. 604.946.9981 f. 604.946.9983 tf. 800.668.3884 US/Canada www.AnalyticSystems.com [email protected]

1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free

from defects in workmanship and materials under normal use and service. 2. This warranty is in effect for: a. 3 Years from date of purchase by the end user for standard products offered in our catalog. b. 2 Years from date of manufacture for non-standard or OEM products c. 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or a. The date of shipment by Analytic Systems, or b. The date of manufacture coded in the serial number, or c. From a copy of the original purchase receipt showing the date of purchase by the user. 4. In case any part of the equipment proves to be defective, the Purchaser should do the following: a. Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and include the date of purchase, the place of purchase, and the Purchasers name, address and telephone number. b. Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization number (RMA). c. Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada. 5. If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return or special handling will incur additional charges and are the responsibility of the Purchaser. 6. Analytic Systems reserves the right to void the warranty if: a. Labels, identification marks or serial numbers are removed or altered in any way. b. Our invoice is unpaid. c. The defect is the result of misuse, neglect, improper installation, environmental conditions, non- authorized repair, alteration or accident. 7. No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. 8. Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall render this warranty void. 9. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for equipment specifically stated to be waterproof. 10. No other express warranty is hereby given and there are no warranties that extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. 11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. 12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Register Products Online | www.analyticsystems.com/support/warranty-registration

DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 [email protected] www.AnalyticSystems.com 8128 River Way Delta, BC V4G 1K5 | Canada Battery Chargers • Inverters • Power Supplies • Voltage Converters