Andatech ACCESSPOINT FRX Operation & User’s Manual
Read Online
Read the Andatech ACCESSPOINT FRX Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Andatech ACCESSPOINT FRX
Facial Recognition Access Control System with Temperature
Screening
User Manual
Version 1.1. Updated September 2020.
Thank you for purchasing the Andatech® Accesspoint FRX breathalyser.
The latest essential for workplaces, health facilities and public venues, the Andatech Accesspoint
FRX offers fast and accurate temperature detection and facial recognition ID to screen employees
and visitors before they even enter your premises. With the ability to be connected to any access
control system, the Accesspoint FRX can also automatically restrict access to those who are running
a fever. Equipped with power infrared thermal imaging technology, the Accesspoint FRX acts as your
premises’ first line of defence, saving valuable time, eliminating direct physical contact and reducing
the need for extra manpower when it comes to temperature screening. Combined with advanced
settings such as guest/visitor mode, mask detection and real time data upload, the Accesspoint FRX
is suitable not only for workplaces but also for schools, hospitals, restaurants, malls, and other high
traffic venues.
We hope you enjoy owning your Andatech® AccessPoint FRX breathalyser. If you have any questions
regarding the unit or want to speak with us further, please visit andatech.com.au or call 1300 800 200
(between 9am and 5.30pm Monday to Friday).
CONTENTS
DEVICE FEATURES
4
LCD SCREEN
5
SPECIFICATIONS
6
DEVICE INSTALLATION
7
GUIDELINES
7
MOUNTING THE DEVICE
8
WALL-MOUNT INSTALLATION
8
CRADLE STAND INSTALLATION
9
ANDALINK
10
SETUP INSTRUCTIONS
10
ADMIN SETUP
10
ANDALINK SYNC
10
FORCE SYNC
10
ABOUT TEMPERATURE CALIBRATION
11
TEMPERATURE CALIBRATION PROCEDURE
11
ADMIN TEMPERATURE CALIBRATION (ON DEVICE STARTUP)
11
INTERVAL TEMPERATURE CALIBRATION
11
2
MANUAL TEMPERATURE CALIBRATION
11
CALIBRATION OPERATORS
12
AMBIENT TEMPERATURE CALIBRATION
12
OPERATING INSTRUCTIONS
13
DEVICE SETTINGS
14
Network
14
Language
15
Records
16
Voice
17
Advanced Setting
18
(a) Temperature
18
(b) Recognition / Card Scan
19
(c) Test Delay
21
Temperature Calibration
22
Calibration by ambient temperature (suitable when the device is in a fixed position)
22
Calibration by body temperature within calibration interval
22
Manual calibration
22
TROUBLESHOOTING / WARNING DISPLAY
23
FACIAL RECOGNITION GUIDELINES
25
FAQs
26
LIABILITY FOR PROPER FUNCTION OR DAMAGE
26
WARRANTY DETAILS
27
3
Optional Accessories for Cradle Stand Version:
●
Simple base
●
Smart base (includes wiring and output ports)
4
32 to 42.5°C
Network
WIFI, 4G (optional), Ethernet
Accuracy
±0.3°C
Extension
Ports
1 USB, 1 RS232, 1 TTL, 1
switch signal, can connect to
electric lock and access gates
Display
8 inch TFT LCD
CPU
Cortex - A53 Octa-Core
1.4GHz
Camera
2 Mega Pixel with visible
light and infrared
EMMC
8GB EMMC 5.1
Facial Recognition
Distance
0.3 to 2m
Ambient
Conditions
Operation: -10 to 75°C
Storage: -20 to 50°C
Humidity: 20% to 95%RH
Facial Recognition
Rate
99.9%
Power
supply
Input: AC 100-240V 50-60Hz
0.8A,
Output: DC 12V 3A
Facial Recognition
Identification
Speed
300ms
Weight
1.28kg
Memory (built-in)
20,000 registered faces,
20,000 test results
Dimensions
23.7cm x 12.7cm x 1.8cm
Andalink memory
(cloud storage)
20,000 registered faces,
20,000 test results
(upgrade options
available)
Warranty
1 year
6
Install the device only indoors, in a covered environment.
●
Install the device in a location with sufficient lighting
●
Do not use the facial recognition feature under a strong light.
●
Do not expose the device to the sun for a prolonged period of time.
●
Do not use in locations that are subject to high humidity. Excessive humidity may cause
damage to the device's components.
●
Do not install in locations with large temperature fluctuations throughout the day as this may
affect temperature calibration and body temperature results.
●
Choose an installation location that has a regular, room temperature - away from direct
sunlight, excessive heat or cold air (e.g. directly facing an air conditioner). Excessively hot or
cold temperatures may affect body temperature readings.
●
Use our provided power adapter- connecting it to an improper power source may damage
your equipment and lead to fire and/or damage.
●
Keep the camera clean for optimum photos and facial recognition.
●
Device should be installed facing directly forward with as little tilt or inclination as possible to
ensure the best body temperature results.
7
MOUNTING THE DEVICE
WALL-MOUNT INSTALLATION
If you have purchased the wall-mounted version, the wall mount bracket would have come
pre-installed onto the device.
To mount on the wall, use the appropriate screws (4) and wall anchors (4) for the type of wall material
you are mounting the device to (screws and wall anchors not provided).
1.
Use a screwdriver to loosen the two screws on the sides of the bracket (image A)
2.
Remove the device from the bracket by sliding the bracket up or down from the device (image
B).
3.
Locate an area on the wall where you want to install the device (be sure to follow the
installation guidelines as mentioned before). Using a pencil and the bracket as a guide, mark
the 4 holes that will need to be drilled into the wall.
Note: The bracket can be positioned in either orientation depending on how you want to
position the wire cable (image D).
4.
Drill the 4 holes on the wall and put the wall anchors inside the holes.
5.
Position the flat side of the bracket against the wall and use screws to secure it into place
(image C).
8
Hang the device onto the bracket by sliding it up or down onto the bracket (image E).
7.
With a screwdriver, tighten the two screws on the sides of the brackets to secure the device
into place (image A).
CRADLE STAND INSTALLATION
1.
Mount the device and cradle stand on the surface.
2.
On the under side of the surface, put the neoprene O ring inside the hexagon nut and screw it
onto the cradle stand until the device is securely positioned in place.
3.
Use a torx screwdriver to adjust the angle of the display panel. The angle can be changed up
to ±30°.
9
The Andalink is a secure, cloud-based software that bridges the AccessPoint FRX with a complete
data management system. With Andalink, company and OH&S managers can register users and
faces, as well as view, download, and manage reports for their employees' attendance and
temperature results. The AccessPoint FRX can also be used with visitor or guest mode, perfect for
conducting temperature screening and automating entrypoint access in public places and high traffic
areas such as hospitals, government buildings, tourist attractions and schools.
SETUP INSTRUCTIONS
For instructions on how to set up your Andalink account for your AccessPoint FRX, please visit
andatech.com.au/andalink-manual and log in with the credentials provided in the letter with your
device during purchase.
ADMIN SETUP
Important: Before operating the AccessPoint FRX, log in to your Andalink account and create at least
one (1) staff that has the user type Admin for each location/device.
An Admin staff is required to conduct the Admin Temperature Calibration on the device during startup.
ANDALINK SYNC
Test results from the device are synced to Andalink immediately (as long as there is an active internet
connection on the device).
All other changes from Andalink to the device are synced every 10 minutes.
FORCE SYNC
To Force Sync the device with Andalink, connect a mouse to the device.
Then click and hold the cursor on the version number (displayed on the bottom right of
the device screen).
The server (cloud) icon will start rotating and display a downward arrow icon to indicate
that it is syncing.
The Force Sync is complete when the icon stops rotating. The number beside the icon will be updated
to show the updated number of registered faces synced from Andalink, and a pop-up message will
appear in the Notification Area that the Force Sync is complete.
10
ABOUT TEMPERATURE CALIBRATION
The Temperature Calibration is required to evaluate and adjust the precision and accuracy of the
AccessPoint FRX's temperature measurements.
TEMPERATURE CALIBRATION PROCEDURE
To perform a Temperature Calibration, a calibration operator stands in front of the AccessPoint FRX
and faces the camera. The device will then take their temperature and use that as the guideline for
'normal body temperature'.
Note: It is recommended that the calibration operator first check their body temperature (e.g. with a
separate accurate, reliable handheld thermometer) to make sure that it
is normal (within 36~36.5°C) before performing the Temperature
Calibration.
ADMIN TEMPERATURE CALIBRATION (ON DEVICE
STARTUP)
Each time the device is switched on, it takes 10 minutes to warm up and
will then require a Temperature Calibration.
This can only be performed by an Admin (set in Andalink).
Note: The device will auto-restart daily at 4AM (device time) by default.
Any software updates are done automatically during restart as long as
your device is connected to the internet.
INTERVAL TEMPERATURE CALIBRATION
During normal operation, the device will also require a Temperature
Calibration at regular intervals (recommended / default setting: 60
minutes).
When the device requires Temperature Calibration, the Thermal
Imaging Display will turn completely orange and the Notification Box will
show 'Please contact calibration operator' if anyone attempts to take a
test.
A normal test cannot be taken until a calibration operator performs the
Temperature Calibration.
MANUAL TEMPERATURE CALIBRATION
If a temperature calibration is needed outside of its regular interval
period (e.g. temperatures seem too high or too low, or is measuring
inconsistently), a manual temperature calibration can be performed.
11
To do this, connect a mouse to the device and enter the Device Settings Menu > Temperature
Calibration and click on 'Start Manual Calibration'. Then, follow the steps under 'Temperature
Calibration Procedure'.
CALIBRATION OPERATORS
By default, only an Admin user (set in Andalink) can conduct the
Interval and Manual Temperature Calibration.
The calibration operator for these can be changed to a non-Admin (any user) under Advanced
Settings (Temperature) by un-ticking the checkbox for 'Temperature calibration by operator only'.
Refer to Advanced Settings (Temperature) for more information.
Note: The calibration operator for Admin Temperature Calibration (on device startup) can only be an
Admin. This cannot be changed in Advanced Settings.
AMBIENT TEMPERATURE CALIBRATION
If ambient temperature calibration is enabled (under ‘Temperature’ settings), the device will check the
environment / ambient temperature and self-calibrate.
Note:
●
The device may ask for a manual calibration (with a calibration operator) if high temperature
fluctuations are detected in the environment.
●
The initial temperature calibration on device startup will still require a calibration by body
temperature (requires a calibration operator to be physically present).
12
Follow the device's instructions shown in the Notification Area when taking a test.
1.
'Face camera. Keep face inside the frame'
Stand in front of the device, face the camera and position face within the Facial Recognition
Frame shown on the LCD display.
Note: Be sure to follow the Facial Recognition Guidelines when facing the camera.
2.
Device will analyse the results and display them in the Notification Area.
a.
If the temperature reading is above the Body Temperature Limit, an alert will sound
and the test procedure ends.
b.
If the temperature reading is below the Body Temperature Limit, the test will proceed
to the next step.
Note: Body Temperature Limit is set under Advanced Settings.
3.
Results are synced to Andalink immediately after each test (if device is connected to the
internet).
4.
A new user can take another test immediately by repeating from Step 1.
13
To access the Device Settings Menu, plug in a USB
mouse into the device and long press (click + hold) the
icon on the bottom left of the screen.
Network
There are 3 methods of connection: Ethernet, Wifi, and 4G (additional module)
Ethernet
Plug in ethernet cable to
connect to the network
automatically.
Wifi
Select SSID and input
password to connect to WIFI
network.
4G
With the device turned off,
insert SIM card into the SIM
slot. Then, turn the device on.
Click on any method of network connection to activate or deactivate it. Once a network preference
has been selected and activated, the corresponding icon will turn blue.
14
Set device language preferences here.
Select the preferred language from the drop down menu then
click
to save.
15
20,000 test records can be stored along with the photo of the users.
Click on
to scroll or
to search for a record.
Click on a record to view details of the test record.
Click on
to print the test record (compatible printer must be connected) or click
to
return to view test records.
16
Control the voice and audio alert volume here.
Voice recorded alerts
Controls the voice recorded alerts such as 'Visitor / Temperature
Reading / Pass'.
Drag the red dot on the bar to adjust the volume level.
To mute or disable all voice alerts on the device, click on the
icon.
The icon will change to
when muted/disabled. Click it again to unmute or enable voice alerts.
Sound alerts
Controls the sound alerts (alarm sounds when temperature is high etc.).
Click on the drop down arrow to change the volume level.
To mute or disable all sound alerts on the device, click on the
icon.
The icon will change to
when muted/disabled. Click it again to unmute or re-enable sound
alerts.
After making changes, click
to save the settings.
Note: The Temperature Calibration alarm sound is controlled under Advanced Settings > Test Delay
17
Requires a password to access either (a) Temperature, (b) Recognition / Card Scan or (c) Test
Delay advanced settings.
(a) Temperature
Enter the password 978166
●
Body Temperature -
○
Tick to enable temperature scanning for all
users
○
Untick to disable temperature scanning for all
users
●
Body Temperature Scale -
○
Tick to select either °C or °F for body
temperature reading.
●
No body temperature limit -
○
Tick to disable all temperature alerts.
■
Temperature pass limit is 0 by default
(all temperature readings will be 'Pass')
○
Untick to set a body temperature limit and alert
sound:
■
Body temperature limit - Set a body temperature limit (e.g. 38.0). Any
detected body temperature above this set limit will sound an alert.
●
Temperature calibration by operator only - Controls the calibration operator setting for
Interval and Manual Temperature Calibration (under 'Temperature Calibration' in Settings
menu).
○
Tick to allow only Admin to conduct the Interval and Manual Temperature Calibration
(default setting).
○
Untick to allow anyone to perform the Interval and Manual Temperature Calibration.
●
Do not display temperature reading -
○
Tick to hide the temperature reading when temperature is scanned.
○
Untick to show the temperature reading (e.g. 37.0°C) when temperature is scanned.
After making changes, click
to save the settings.
18
(b) Recognition / Card Scan
Enter the password 978165
●
Enable Facial Recognition
○
Untick this to enable the device's facial
recognition feature (default setting).
○
Tick this to disable the device's facial
recognition feature
●
Visitors Allowed -
○
Tick this to enable non-registered users
(visitors) to use the device.
■
Device will display user ID as
'Visitor'.
■
Andalink will store visitor's picture
and test results. User ID will be
recorded as 'Guest Mode: User
not registered'.
■
Registered users will be able to use the device as normal (user's name will
be recorded).
○
Untick this to allow only registered users to use the device.
■
If a non-registered user uses the device when visitors are not allowed, it will
display “FAIL” and the visitor cannot take a test on the device.
●
Enable Mask Detection
○
Tick to enforce all users to wear a mask. If a user is detected as not wearing a mask,
device will notify 'PLEASE WEAR A MASK' and sound an alert. Users cannot take a
test unless a mask is detected.
■
Note: If Mask Detection is enabled, the setting 'Visitors Allowed' must also be
enabled as the device cannot conduct any facial recognition on registered
staff.
○
Untick to disable mask detection.
●
Enable / Disable Live Detection
○
Select ‘enable’ to allow the device to operate only if there is a real person detected in
front of the device.
○
Select ‘disable’ to allow the device to operate even if a real person is not detected in
front of the device (e.g. a picture of a person is shown to the camera). This option is
less secure.
19
Enable / Disable Fill Light
○
Select ‘enable’ to switch on the LED fill light on top of the device. This can assist in
making facial features clearer so that the facial recognition camera can function
properly, especially if the device is in a low light environment.
○
Select ‘disable’ to switch off the LED fill light on top of the device. When disabled, the
LED fill light will switch off when the device does not detect any person in front of the
device within 10 seconds.
●
Photosensitive Control
○
Select this option to turn on the LED fill light only if a person is detected in front of the
device. The light is controlled based on the environment.
●
Full Picture
○
Tick this option to enable the camera to take a full picture of the user including the
background.
○
Untick this option to crop out the image of the user’s face (taken within the facial
recognition frame) when taking a picture.
●
Ambiguity
○
Determines the rate of ambiguity allowed in the facial recognition algorithm. Can be
set from 0.0 - 1.0.
○
The default and recommended setting is 0.5.
○
The lower the number of ambiguity, the stricter the FR algorithm, e.g. at ‘0’ the user
will need to stand very still in order to take a test.
After making changes, click
to save the settings.
20
(c) Test Delay
Enter the password 119119
●
Test success delay - Enter the time delay (in
seconds) required after a successful test before the
start of the next facial recognition test.
This interval time is especially important when the
device is connected to an access gate system to
allow enough time for the door to open and close
after a test.
●
Turn off calibration alarm - This controls the
Temperature Calibration alarm sound.
○
Tick to disable the temperature calibration
alarm
○
Untick to enable the temperature
calibration alarm.
21
The Temperature Calibration is required to evaluate and
adjust the precision and accuracy of the AccessPoint FRX's
temperature measurements.
This can be done in two ways - with ambient temperature or
with body temperature (requires calibration operator).
Please read 'About Temperature Calibration' for more
information.
Calibration by ambient temperature (suitable when the
device is in a fixed position)
Enable this to allow the device to check the environment /
ambient temperature and self-calibrate.
Note:
●
The device may ask for a manual calibration (with a
calibration operator) if high temperature fluctuations
are detected in the environment.
●
The initial temperature calibration on device startup will still require a calibration by body
temperature (requires a calibration operator to be physically present).
Calibration by body temperature within calibration interval
By default, the device will require a Temperature Calibration every 60 minutes. This is the
recommended interval.
Although not advisable, you can select a different temperature calibration interval from the drop down
menu.
After changing the interval, click on the 'Start manual calibration' button to save the new calibration
interval setting and conduct a manual temperature calibration.
A calibration operator needs to be physically present to conduct the temperature calibration on the
device. Refer to 'Temperature Calibration Procedure' for instructions.
Manual calibration
If a temperature calibration is needed outside of its regular interval period (e.g. temperatures seem
too high or too low, or is measuring inconsistently), a manual temperature calibration can be
performed.
To do this, just click on the 'Start manual calibration' button.
A calibration operator needs to be physically present to conduct the temperature calibration on the
device. Refer to 'Temperature Calibration Procedure' for instructions.
22
TROUBLESHOOTING / WARNING DISPLAY
Issue / Warning Display
Possible Cause(s)
Solution(s)
Fail!
User is not registered as staff and
‘Visitors Allowed’ is disabled.
Register user as staff in Andalink or
enable ‘Visitors Allowed’ under
‘Advanced Settings (Recognition / Card
Scan)’.
Please contact
calibration operator
and/or
Thermal Imaging
Display is orange
The device requires Temperature
Calibration.
Perform a temperature calibration
following the instructions under
‘Temperature Calibration Procedure’.
Body Temperature:
XX.X°C Fail!
The detected body temperature was
higher than the set limit.
Check and change the body temperature
limit (e.g. 38.0°C) under ‘Advanced
Settings (Temperature)’ if it is too low.
Body Temperature is
too high (e.g. 38.0°C)
but the user passed
No Body Temperature Limit was set
(default limit is 0°C - any
temperature will Pass) or was set too
low (e.g. 32.0°C).
Go to Advanced Settings (Temperature)’
and set a body temperature limit (e.g.
37.5°C).
Device not recognising
or detecting user or
face correctly
User’s face is not within the Facial
Recognition Frame.
Position user so that face is within the
Facial Recognition Frame.
User is not following Facial
Recognition Guidelines.
Ensure users are following Facial
Recognition Guidelines.
Also, ensure that the user's photo in
Andalink is following Facial Recognition
Guidelines.
User is not registered in Andalink or
device.
Register the user in Andalink or device.
User was recently registered in
Andalink but not yet synced to the
device.
Ensure the device is connected to the
internet. Wait 10 minutes or Force Sync
to sync user to device.
User is not registered and Visitors
Mode is disabled.
Register user or enable Visitors Mode
under ‘Advanced Settings (Recognition /
Card Scan)’.
Mask Detection is enabled but
‘Visitors Allowed’ is disabled.
Either disable ‘Mask Detection’ or enable
both ‘Mask Detection and ‘Visitors
Allowed’ under ‘Advanced Settings
23
(Recognition / Card Scan)’.
Users are being
detected as Visitor /
Guest although already
registered as staff in
Andalink
User was recently registered in
Andalink but not yet synced to
device.
Ensure device is connected to the
internet. Wait 10 minutes or Force Sync
to sync user to device.
Facial Recognition was disabled.
Untick the ‘Without Recognition’ setting
under ‘Advanced Settings (Recognition /
Card Scan)’ to enable Facial Recognition
feature.
Mask Detection is enabled.
Disable Mask Detection under
‘Advanced Settings (Recognition / Card
Scan)’.
Device is not
responding or the
display screen is frozen
Device requires a restart
Restart the device.
Temperature readings
are highly inaccurate or
inconsistent
Device installation did not follow
guidelines.
Ensure device installation follows
guidelines under ‘Device Installation’,
including:
-
Device is not tilting too much
upwards or downwards
-
Room does not have large
temperature fluctuations or is
constantly too hot or too cold
-
Heater or air conditioner is not
close or blowing directly onto
device
Perform a Manual Temperature
Calibration. Ensure that the calibration
operator has a normal body temperature
(e.g. 36~36.5°C).
Room temperature has large
temperature fluctuations.
Temperature calibration performed
incorrectly.
Temperature calibration performed
when the environment was too hot or
too cold.
Calibration operator did not have
normal body temperature.
24
1. Can a user delete or edit their details or test results?
No, this cannot be done on the device or in Andalink by any user (including by Admins or Managers).
2. How instant are the AccessPoint FRX's test results, changes and updates synced to
Andalink?
They sync automatically every 10 minutes. You can do a Force Synchronisation to sync it instantly.
3. What will happen if the Wi-Fi or internet is down in my location?
The AccessPoint FRX will continue to operate and save test results offline. Once it is connected to the
internet or Wi-Fi network again, it will sync the results to the Andalink.
LIABILITY FOR PROPER FUNCTION OR DAMAGE
The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator
in the event the instrument is serviced or repaired by personnel not employed or authorised by
Andatech. In such an event, the warranty will be void.
26
Register your warranty online now at my.andatech.com.au
Congratulations on your purchase! It is our aim to provide you with quality products that you can trust. Our
products come with guarantees that cannot be excluded under the Australian Consumer Law.
You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a major failure.
The Guarantee
The product is guaranteed to be free from defects in workmanship and parts for a period of 12 months from the
date of purchase for domestic use and 3 months for commercial use. Defects that occur within this warranty
period, under normal use and care, will be repaired, replaced or refunded at our discretion, solely at our option
with no charge for parts and labour. The benefits conferred by this warranty are in addition to all rights and
remedies in respect of the product that the consumer has under the Trade Practices Act and similar state laws.
Proof of Purchase
This warranty is valid for the original purchase and is not transferable. Please keep your purchase docket or
receipt as proof of purchase and as proof of date on which the purchase was made. The purchase docket (or a
copy) or receipt must be presented with the warranty when making a claim under this warranty.
Service during the Warranty Period
To claim for warranty, contact us on 1300 800 200 or [email protected] to get an RA# (Return
Authorisation Number). Ensure that the RA# is clearly stated on the outside of the packaging and that the product
is properly packaged so that no damage occurs to the product during transit. Shipping of the product back to us
for warranty will be at our cost. A product return without the RA# or proof of purchase will not be accepted.
Extent of Warranty
This warranty is limited to defects in workmanship or parts. All defective products or parts will be repaired or
replaced. This warranty does not cover manuals and packaging.
Normal Wear and Tear
This warranty does not cover normal wear and tear to the product or parts.
Exclusions
This warranty does not cover:
●
Any defect caused by an accident, misuse, abuse, improper operation, lack of reasonable care,
unauthorised modification, loss of parts, tampering or attempted repair by a person not authorised by
the distributor.
●
Any product that has been damaged by a lightning strike either directly or indirectly or a main power
surge or liquid ingress.
●
The product if it is located outside of Australia.
●
Any damage caused by improper power input or improper cable connection.
Andatech Pty. Ltd.
PO Box 3038, Nunawading VIC 3131, Australia.
Phone: 1300 800 200 Fax: 1300 883 802 Email: [email protected]
27