Thank you for purchasing the Andatech® Prodigy 3.

The Andatech® Prodigy 3 is a state-of-the-art device used to detect Ethyl Alcohol from a valid breath sample. It uses an electrochemical fuel cell to measure the concentration of alcohol from the breath sample expelled from a human subject. If alcohol is present, a corresponding voltage is generated from the fuel cell, which is proportional to the alcohol content of the sample provided by a human subject. This voltage is then sent to the CPU and converted to a subject’s BAC (blood alcohol concentration), which is then displayed. The operator of this device should read the operation manual and be familiar with the device operation before using it. Retain the manual for future reference. Prodigy 3 Features 1. Stores more than 100,000 test records along with full data and photographs. Test records can be uploaded to a computer for record keeping. 2. Uses disposable mouthpieces or sampling cups to prevent foreign matter from entering. 3. A hard plastic case is included for storing the device and its accessories for easy transport. When not in use, the device and its accessories should be stored in this hard case to prevent damage. 4. Ability to take consecutive tests as needed. Recovery time between tests on average is 30 seconds (between positive tests). 5. Powered by a High-capacity lithium battery. The battery is located behind the sliding cover on the back of the device. The level of power left in the battery is indicated on the screen. A cigarette plug adapter is also included for use by the operator. 6. Storage temperature range is -30°C to 70°C and storage humidity is 15% to 90% RH (relative humidity). Inappropriate storage of the device will shorten the lifespan of the fuel cell sensor. 7. Saves the GPS location of the test. 8. Immediate data transmission by 3G/4G and WIFI. CONTENTS SPECIFICATIONS PRODUCT DIAGRAM FEATURES SCREEN DISPLAY CONDITIONS FOR TESTING OPERATING INSTRUCTIONS PRINTER DISCLAIMERS LIMITS WARRANTY REGISTRATION CALIBRATION AND SERVICE WARRANTY DETAILS .....................................................3 ................................................3 ................................................................4 ....................................................5 ....................................6 ...................................7 ................................................................10 ........................................................10 ....................................................................11 ..................................11 ................................11 .............................................12

1 x Prodigy 3 Breathalyser

1 x Hard Case 1 x Soft Pouch 2 x Rechargeable Batteries 1 x 12V Car Charging Cable 1 x 12V Power Adapter (AU Plug) 1 x Battery Charging Dock 1 x Micro USB Cable 1 x Sampling Cup 5 x Mouthpieces 10 x Printer Rolls 1 x User Manual BAC Range 0.000% - 0.400%BAC Result readings can also be changed to the following formats. Please specify this during purchase or calibration: BAC BrAC 0.000 ~ 4.000 ‰ 0.000 ~ 2.000 mg/l BrAC 0.000 ~ 0.400%BAC 0.000 ~ 4.000 g/l 0~40.0 mg/100ml 0~200µg/100ml 0~2000µg/l Accuracy ±0.005%BAC at 0.100%BAC Warm Up Time Within 5 seconds Response Time Within 5 seconds Recycle Time 3 seconds Operating System Android 5.1 Camera 4.3” TFT colour touch screen GPS ±5M Connection USB, WIFI Printer Built-in Thermal Printer Storage Temperature -30 to 70°C, 15 to 90%RH Working Temperature -10 to 50°C Power Supply 7.4V 2,000mAh NI-MH rechargeable battery pack Mouthpieces Manufacturer Recommended: Unlimited tests every 6 months Australian Standards Requirement: Every 6 months Memory Capacity 100,000 test records including all information Calibration Manufacturer Recommended: Unlimited tests every 6 months Weight Australian Standards Requirement: Every 6 months Dimensions (mm) 20cm x 22cm x 8.8cm Warranty 1 Year On/Off Button Camera Up Button Touch Screen Down Button Printer Button to Remove Mouthpiece Sample Port

PLEASE REFER TO DIAGRAM ON PREVIOUS PAGE

1. Disposable Mouthpiece Each mouthpiece is individually packaged and sealed for hygiene reasons. Before each new Standard Test, attach a new mouthpiece to the sample port to prevent contamination from a previous test. 2. Sampling Cup The sampling cup can be used for Passive Tests and is reusable as long as no alcohol is detected in the previous test. Each sampling cup is also individually sealed. Attach a sampling cup to the sample port to take a passive test. Do not allow the mouth to touch the sampling cup during testing. After use, remove the sampling cup and clean it with alcohol or boiling water. Allow it to dry completely before re-using it. 3. Button to Remove Mouthpiece The mouthpiece can be removed from the breathalyser hygienically by pushing this button up. This will eject the mouthpiece for easy disposal without touching the mouthpiece. 4. Touch Screen Display This displays the instructions and the alcohol concentration reading of breath tests taken on the unit. Select the icons and buttons on the screen using the stylus pen provided. 5. Camera Takes a picture of the subject providing the breath sample. 6. On/Off Button Press and hold the On/Off button to turn the device on or turn off. 7. Battery Charging The battery can be charged while inside the device or using the included battery charging dock. The battery charging indicator turns red when the battery is charging, and green when the battery is fully charged. 8. External Power Connectors Connectors for 12V car (cigarette) adapter or optional 12V power transformer. The battery can be charged while inside the device. 9. USB Cable Use the USB cable to upload test records stored in the internal memory and upgrade the software. FEATURES

1. GPS Indicator

2. WIFI Indicator 3. 3G Indicator 4. Battery Indicator 5. Date & Time Indicator 6. Standard Test 7. Passive Test 8. Test Records 9. Calibration 10. Setting 11. GPS 12. 3G/4G Setting (Optional) 13. WIFI Setting 14. Last Calibration Date 15. Next Calibration Date 16. Test Record Counter SCREEN DISPLAY Confirm / Enter Next Screen Restore Previous Screen Print Edit Cancel Save Search

MEASUREMENTS & CONDITIONS FOR TEST

• Use a clean mouthpiece for each test. • The optimum temperature range for operating the unit is -10°C to 50°C. Use within this temperature range will limit condensation from a subject’s breath and ensure an accurate reading is taken. • Do not allow samples containing smoke,tobacco or other chemical products to enter the unit, as damage to the fuel cell sensor can occur. • It is recommended that the operator observe the subject for approximately 20 minutes before administering the breath test. This is to ensure the subject does not consume anything. Following this procedure will ensure the subject’s saliva is clear of alcohol so that it does not alter the outcome of the breath sample test. • There must be an interval of at least 15 minutes after alcohol consumption as alcohol residue in the mouth may give a false reading. Such residue may also be left by aromatic drinks, mouthwash, medicines and drops, as well as by belching and vomiting. Mouth rinsing with water or non-alcoholic drinks does not substitute for an interval. • A person’s blood alcohol concentration (BAC) can continue to rise for up to 2 hours after drinking alcohol. If a result is close to the designated BAC, it is recommended to wait and retest after 20 minutes. • It can take 10 hours or more for a person’s BAC to return to zero after a high BAC has been reached. A further test should be carried out later in the day or the following morning. CONDITIONS FOR TESTING LIABILITY FOR PROPER FUNCTION OR DAMAGE The liability for proper functioning of the instrument is irrevocably transferred to the owner or operator in the event the instrument is serviced or repaired by personnel not employed or authorised by Andatech. In such an event, the warranty will be void. OPERATING CONDITIONS Working temperature of the Andatech® Prodigy 3: -10 to 50°C Storage temperature range of the Andatech® Prodigy 3: -30 to 70°C, 15 to 90%RH Note: Inappropriate storage of the device will shorten the lifespan of the fuel cell sensor.

Refer to “Conditions for Testing” before conducting a Standard or Passive test.

On/Off Press and hold the power button for 1-2 seconds to switch the device on or off. Taking a standard test 1. Attach a mouthpiece onto the sample port and select the Standard Test icon. 2. The breathalyser will take a Blank Test to ensure the mouthpiece and sensor are clear of alcohol from previous tests. 3. If the Blank Test result shows 0.000, the unit will proceed to test mode (skip to step 5). 4. If alcohol is detected, verify that a clean mouthpiece is being used and select retest. 5. Use the stylus pen to input information. 6. When the screen displays “Please Blow”, take a deep breath and blow into the mouthpiece with a slow and steady breath until the BEEP tone stops and the Time and Volume bars are full. • A photo will be taken while the subject is blowing. • A passive test can be taken by pressing the icon while the subject is still blowing. 7. The test result will display on the screen. Press to go to the next screen (review results). 8. If the subject did not blow within 30 seconds, the administrator can press to confirm that the subject refused to take a test, or press to allow the subject to take a test again, or to exit. 9. If the subject failed to give a valid breath sample, the administrator can press to confirm or to allow the subject to take the test again. 10. Select to print the test result. 11. Push the button underneath the mouthpiece to remove the mouthpiece and take another test. Taking a passive test 1. Attach a sampling cup onto the sample port and select the Passive Test icon. 2. When the screen displays “Please Blow”, take a deep breath and blow into the sampling cup until the BEEP tone stops. 3. Press to take a manual sample while the subject is still blowing into the sampling cup. 4. An “Alcohol Detected” or “No Alcohol” result will display on the screen. 5. The next test can be taken immediately after a “No Alcohol” result. 6. If “Alcohol Detected” result was displayed, use a mouthpiece to perform a Standard Test to confirm the test result.

7. If alcohol was detected during a passive test, clean the sampling cup or use a new sampling cup

to prevent residual alcohol from affecting the next test result. 8. Select to print the test result. Note: A passive test only checks for the presence of alcohol in a breath sample. An accurate test result can only be obtained via a Standard Test using a mouthpiece. Passive test results will not be stored in the device but can be printed immediately after a test is taken. Record 1. The device can store over 100,000 test records along with the subject’s photo. 2. Select the Record icon to view details of past test records. 3. Select to print out individual test records. 4. Select to search for test records based on their record number, date, time, mode or result. Then press again to confirm. Calibration 1. When the screen displays “Calibration Needed”, it means the device has passed its calibration due date. 2. Contact an authorised calibration centre to get the device calibrated. GPS 1. Shows the longitude and latitude of the device location. 2. The longitude and latitude of the test is stored and printed on the printout. 3. Uncheck the “Print GPS” tickbox under the “Print” Settings to disable printing the GPS location on test records. Note: The GPS function requires 3-8 minutes after startup to begin locating correctly. Ensure the device is in an open area in order to receive a signal. If no GPS signal is detected, the longitude and latitude will not be shown on the printout. 3G/4G 1. Applicable for devices with 3G/4G module only. 2. Insert SIM card. 3. Apply your preferred cellular network settings.

1. Enter the WI-FI information to connect to the WIFI.

Setting 1. Basic Settings Adjust the screen brightness level and sleep time. 2. Time Setting Set the device date and time. 3. Print • Print GPS: Tick the checkbox to print the GPS location of the test on the printout. • Print Photo: Tick the checkbox to print the photo of the subject on the printout. 4. Device Info Displays the device information such as the software version number, next and last calibration date, and total number of tests. 5. Upload If a backend server is used for data upload, the IP address of the server is shown (IP address can only be changed in Advanced Settings). Set Auto Upload if needed. 6. Advanced Only authorised calibration technicians can enter the device’s Advanced Settings. 7. Skip Data Entry Tick this checkbox to skip entering data before each Standard Test. Untick to re-enable entering data.

The Prodigy 3 features a built-in thermal printer.

• This product must be used strictly in accordance with the instructions in this manual. • This product is intended to provide the user with an indication of alcohol on the breath. However, neither the manufacturer nor the supplier gives any warranty (express or implied) that the product can give any indication of blood alcohol level. • A person’s BAC (Blood Alcohol Concentration) can only be accurately measured by the administration of a blood test. This product only measures breath alcohol content which, in turn, only gives an approximate indication of blood alcohol concentration. INSERT/REPLACE PAPER: Pull the handles on the side to open the printer cassette and inset thermal paper. When inserting a new roll of paper, make sure the glossy/outer side of the paper is facing the serrated tear strip once the door is closed. NOTE: If nothing can be printed, change the orientation of the paper roll and try again. STANDARD THERMAL PAPER WIDTH 57mm x 24mm

The manufacturer warrants for 1 year from

the date of purchase, the product to be free from defects in workmanship or material (excluding calibration) under normal use. The manufacturer’s obligation under this warranty is limited to replacing, adjusting or repairing the unit if returned along with its proof of purchase. This warranty is void if the unit has been tampered with, damaged or abused in any way. To register your warranty online, go to my.andatech.com.au LIMITS AUSTRALIAN BLOOD ALCOHOL LIMITS: Adult License 0.05% Some drivers are restricted to lower levels of BAC. Please refer to your local transport authority for your correct limit. If in any doubt do not drink and drive. The safest level when driving is none at all. Alcohol impairs your judgement and can make you drowsy and sleepy. CALIBRATION AND SERVICE Andatech recommends the AlcoSense® Prodigy 3 is calibrated every 6 months (unlimited tests) to maintain Australian Standards. For recalibration and technical support, please go to my.andatech.com.au or contact: Andatech Hotline: 1300 800 200 (within Australia) +613 8899 6900 (International) Email: [email protected] Website: www.andatech.com.au • In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of his blood alcohol concentration or of his level of intoxication or of his fitness to drive and in particular should not take any action in reliance on such information as the product can provide no more than an indication of alcohol on the breath. • If the user of this product makes any decision or takes any action based on the use of the product such decision or such action shall be at the sole risk of the user and neither the manufacturer nor the supplier assumes any responsibility for such decision or action. In particular, neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led him to believe that he was fit to operate a motor vehicle and is subsequently found not to be so fit. • In particular, neither the manufacturer nor the supplier shall be in any way liable if the user of the product asserts that the product led them to believe they were fit to operate a motor vehicle and are subsequently found not to be so fit. THINGS TO REMEMBER: 1. Always wait a minimum of 15 minutes after your last drink before testing. 2. NEVER take a sip of alcohol and blow immediately into the device. 3. Ignoring these two points WILL cause damage to the unit that is NOT covered by warranty.

It is our aim to provide you with quality products that you can trust. Our products come with

guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The Guarantee The product is guaranteed to be free from defects in workmanship and parts for a period of 1 year from the date of purchase. Defects that occur within this warranty period, under normal use and care, will be repaired, replaced or refunded at our discretion, solely at our option with no charge for parts and labour. The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Trade Practices Act and similar state laws. Proof of Purchase This warranty is valid for the original purchase and is not transferable. Please keep your purchase docket or receipt as proof of purchase and as proof of date on which the purchase was made. The purchase docket (or a copy) or receipt must be presented with the warranty when making a claim under this warranty. Service during the Warranty Period To claim for warranty, contact us on 1300 800 200 or send and email to [email protected] to get an RA# (Return Authorisation Number). Ensure that the RA# is clearly stated on the outside of the packaging and that the product is properly packaged so that no damage occurs to the product during transit. Shipping of the product back to us for warranty will be at your cost. A product return without the RA# or proof of purchase will not be accepted. Extent of Warranty This warranty is limited to defects in workmanship or parts. All defective products or parts will be repaired or replaced. This warranty does not cover manuals and packaging. Normal Wear and Tear This warranty does not cover normal wear and tear to the product or parts. Exclusions This warranty does not cover: • Calibration costs. • Any defect caused by an accident, misuse, abuse, improper operation, lack of reasonable care, unauthorised modification, loss of parts, tampering or attempted repair by a person not authorised by the distributor. • Any product that has been damaged by a lightning strike either directly or indirectly or a main power surge or liquid ingress. • The product if it is located outside of Australia. • Any damage caused by improper power input or improper cable connection. WARRANTY DETAILS