Text of the manual
Data Multiplexer Extend (DMXtend)
|
Release 10.0
Installation Manual
365-372-327R10.0
Issue 1
|
January 2013
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2013 Alcatel-Lucent. All Rights Reserved.
Conformance statements
Federal Communications Commission (FCC) Part 15 Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protections against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s expense.
Security statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of remote access features. In such an event, applicable tariffs
require that the customer pay all network charges for traffic. Alcatel-Lucent cannot be responsible for such charges and will not make any allowance or give any credit for charges
that result from unauthorized access.
Limited warranty
Alcatel-Lucent provides a limited warranty for this product. For more information, consult your local Alcatel-Lucent customer support team.
i i i
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Contents
About this document
Purpose ...................................................................................................................................................... xiii
Reason for reissue ..................................................................................................................................... xiii
Intended audience ...................................................................................................................................... xiii
\How to use this document .........................................................................................................................xiv
Safety information .................................................................................................................................... xvii
Conventions used ...................................................................................................................................... xvii
Technical support .................................................................................................................................... xviii
How to order .............................................................................................................................................. xix
How to comment ....................................................................................................................................... xix
Packaging collection and recovery requirements ...................................................................................... xix
Material content compliance ..................................................................................................................... xix
1
Safety
Laser safety ............................................................................................................................................... 1-1
Electrostatic discharge ESD considerations .............................................................................................. 1-3
Laser product classification ....................................................................................................................... 1-9
Alcatel-Lucent 1665 DMXtend optical specifications ............................................................................ 1-11
Part I: Physical and power installation
2
Physical installation
Planning ..................................................................................................................................................... 2-1
Inspection .................................................................................................................................................. 2-5
Alcatel-Lucent 1665 DMXtend center divider .......................................................................................... 2-5
Alcatel-Lucent 1665 DMXtend shelf installation ..................................................................................... 2-8
Power cable installation ........................................................................................................................... 2-13
Final operations ....................................................................................................................................... 2-17
3
Cable and fiber installation
Planning ..................................................................................................................................................... 3-2
Connector references ................................................................................................................................. 3-4
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Contents
Inspection .................................................................................................................................................. 3-5
DS1/E1 cable installation .......................................................................................................................... 3-6
DS3/EC-1 cable installation .................................................................................................................... 3-13
10/100BASE-T Ethernet cable installation ............................................................................................. 3-36
Ethernet cabling to SFP modules on circuit pack faceplates .................................................................. 3-40
IAO LAN and TCP/IP cable installation ................................................................................................. 3-41
Modem cable installation ........................................................................................................................ 3-44
Sync cable installation ............................................................................................................................ 3-46
Office alarm cable installation ................................................................................................................ 3-50
Miscellaneous (environmental) discrete telemetry cable installation ..................................................... 3-54
OC-3/OC-12/OC-48/OC-192 main optical fiber cable installation ........................................................ 3-58
OC-3/OC-12/OC-48 low-speed optical fiber cable installation .............................................................. 3-61
100/1000BASE-X optical fiber cable installation ................................................................................... 3-62
CIT (RS-232) cable installation .............................................................................................................. 3-64
Final operations ....................................................................................................................................... 3-66
4
Circuit pack installation
Description ................................................................................................................................................ 4-1
Powering ................................................................................................................................................... 4-2
Circuit pack compatibility ......................................................................................................................... 4-6
Initial circuit pack installation ................................................................................................................... 4-9
Part II: Stand-alone installation tests
5
Stand-alone node setup
Software installation ................................................................................................................................. 5-2
Circuit pack installation ............................................................................................................................ 5-3
Use of WaveStar® CIT software ................................................................................................................ 5-6
Circuit pack program version verification .............................................................................................. 5-12
Alcatel-Lucent 1665 DMXtend shelf initialization ................................................................................ 5-13
6
Stand-alone installation testing
LBO software settings ............................................................................................................................... 6-4
Clearing alarms ......................................................................................................................................... 6-7
Local equipment and cross-connect tests .................................................................................................. 6-8
DS1/E1 testing .......................................................................................................................................... 6-9
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
............................................................................................................................................................................................................................................................
Contents
DS3/EC1 testing ...................................................................................................................................... 6-15
LNW74 and LNW87 testing ................................................................................................................... 6-22
OC-3 low-speed testing ........................................................................................................................... 6-24
OC-12 low-speed testing ......................................................................................................................... 6-29
OC-48 low-speed testing ......................................................................................................................... 6-32
OC-192 low-speed testing ....................................................................................................................... 6-36
LED test ................................................................................................................................................... 6-40
Office alarm test ...................................................................................................................................... 6-41
Automatic protection switching and alarm test ....................................................................................... 6-45
Manual switching tests ............................................................................................................................ 6-49
External timing verification ..................................................................................................................... 6-52
Miscellaneous (environmental) discrete telemetry test ........................................................................... 6-55
Modem connection test ........................................................................................................................... 6-59
Final operations ....................................................................................................................................... 6-61
Part III: Network turn-up and testing
7
Connecting adjacent network elements
Fiber installation ........................................................................................................................................ 7-3
Optical transmission test (OC-192, OC-48, OC-12, OC-3) .................................................................... 7-10
Automatic protection switching test ........................................................................................................ 7-11
Manual switching tests ............................................................................................................................ 7-13
Final operations ....................................................................................................................................... 7-15
8
WDMX setup and testing: integration procedures
Turn-up and test the LNW785 8-channel OMD ....................................................................................... 8-4
Turn up and test the LNW705 muxponder ................................................................................................ 8-6
Integrating the LNW705 into the LNW785 .............................................................................................. 8-9
Removing provisioning and equipage from the LNW705 and LNW785 ............................................... 8-11
Connecting the ring (Mains) to the WDMX ........................................................................................... 8-14
Removing provisioning and equipage from the LNW785 ...................................................................... 8-16
Part IV: Miscellaneous detailed installation procedure and reference
material
A
Fiber cleaning
Equipment requirements and recommendations ...................................................................................... A-2
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Contents
Safety instructions .....................................................................................................................................A-3
Cleaning/inspecting optical connectors ....................................................................................................A-3
Cleaning pluggable optics module ............................................................................................................A-9
B
Pluggable Transmission Module (PTM) installation
PTM modules ............................................................................................................................................B-2
Install pluggable modules .........................................................................................................................B-8
C
Installing fiber connectors and LBOs
LBOs .........................................................................................................................................................C-2
Attenuation for circuit packs and PTMs ...................................................................................................C-4
Fiber connections ......................................................................................................................................C-7
D
Backplane pin replacement
Pin and connector background ..................................................................................................................D-2
Repair kits and tools ..................................................................................................................................D-3
Simple repair methods ..............................................................................................................................D-4
Replacement methods ...............................................................................................................................D-5
E
Fiber labeling
Fiber description .......................................................................................................................................E-1
Fiber labels ................................................................................................................................................E-3
GL
Glossary
GL
Terms and definitions
v i i
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
List of tables
1
Alcatel-Lucent 1665 DMXtend documentation set ................................................................1-xviii
1
Safety
1-1
Laser classes ............................................................................................................................... 1-10
1-2
Alcatel-Lucent 1665 DMXtend optical circuit pack laser safety specifications ........................ 1-11
1-3
Alcatel-Lucent 1665 DMXtend optical PTM laser safety specifications .................................. 1-12
1-4
Dispersion-limited receiver sensitivity for OC-192 DWDM PTMs .......................................... 1-21
I-1
Computer requirements .................................................................................................................I-5
I-2
Installation checklist ......................................................................................................................I-6
2
Physical installation
2-1
Cable requirements and options ................................................................................................... 2-4
2-2
Power cable assemblies .............................................................................................................. 2-16
2-3
Power connections ...................................................................................................................... 2-16
3
Cable and fiber installation
3-1
Cable requirements and options ................................................................................................... 3-3
3-2
DS1/E1 cable assemblies ............................................................................................................. 3-9
3-3
DS1 transmission connections ................................................................................................... 3-11
3-4
DS3/EC-1 cable assemblies ....................................................................................................... 3-17
3-5
Twenty-four cable DS3/EC-1 transmission connections ........................................................... 3-24
3-6
Twelve cable DS3/EC-1 transmission connections .................................................................... 3-28
3-7
DS1 and DS3 hybrid cable assemblies ....................................................................................... 3-33
3-8
DS1 and DS3 hybrid cable DS3 transmission connections ....................................................... 3-35
3-9
DS1 and DS3 hybrid cable DS1 transmission connections ....................................................... 3-35
3-10
10/100Base-T Ethernet cable assemblies ................................................................................... 3-38
3-11
10/100BaseT Ethernet connections ............................................................................................ 3-39
3-12
GbE ethernet cables .................................................................................................................... 3-40
3-13
LAN 10BaseT cable assemblies ................................................................................................. 3-42
3-14
LAN 10Base-T cross-over cable connections ............................................................................ 3-44
3-15
LAN 10Base-T straight-through cable connections ................................................................... 3-44
3-16
Modem cable assemblies ............................................................................................................ 3-45
v i i i
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
List of tables
3-17
Modem cable connections .......................................................................................................... 3-46
3-18
Synchronization cable assemblies (SYNC1 and SYNC2) ......................................................... 3-49
3-19
Synchronization cable (DS1 timing reference) connections ...................................................... 3-50
3-20
Office alarm cable assemblies .................................................................................................... 3-53
3-21
Alarm office connections ........................................................................................................... 3-53
3-22
Miscellaneous discrete cable assemblies ................................................................................... 3-57
3-23
Miscellaneous (environmental) discrete telemetry connections ................................................ 3-57
3-24
CIT Cable Assembly .................................................................................................................. 3-64
3-25
Standard CIT cable connection .................................................................................................. 3-65
3-26
RJ-45 to DB-9 connector connections ....................................................................................... 3-65
4
Circuit pack installation
4-1
Alcatel-Lucent 1665 DMXtend shelf power supply requirements .............................................. 4-2
4-2
R10.0circuit pack slot compatibility ............................................................................................ 4-6
4-3
OC-3 mains with 6 STS-1s of vt switch fabric ............................................................................ 4-8
4-4
OC-12 mains with 12 STS-1s of vt switch fabric ........................................................................ 4-8
4-5
OC-48 Mains with 48 STS-1s of vt switch fabric ........................................................................ 4-9
4-6
OC-192 circuit packs with 192 STS-1s of vt switch fabric (VLF) .............................................. 4-9
4-7
OC3/12/48 circuit packs with 192 STS-1s of vt switch fabric (VLF) ......................................... 4-9
4-8
Alcatel-Lucent 1665 DMXtend shelf ........................................................................................... 4-9
5
Stand-alone node setup
6
Stand-alone installation testing
6-1
Office alarm connections ........................................................................................................... 6-42
6-2
Miscellaneous (environmental) discrete telemetry connections ................................................ 6-58
7
Connecting adjacent network elements
7-1
Attenuation table .......................................................................................................................... 7-6
8
WDMX setup and testing: integration procedures
8-1
Channel/port assignments .......................................................................................................... 8-13
8-2
XM10G/8 PTM port guidelines ................................................................................................. 8-14
8-3
Channel/port assignments ......................................................................................................... 8-19
8-4
Attenuation Table ....................................................................................................................... 8-19
A
Fiber cleaning
A-1
Required and recommended equipment and materials ................................................................A-2
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
............................................................................................................................................................................................................................................................
List of tables
B
Pluggable Transmission Module (PTM) installation
B-1
Alcatel-Lucent approved PTMs ...................................................................................................B-2
C
Installing fiber connectors and LBOs
C-1
Circuit pack attenuation table .......................................................................................................C-4
C-2
PTM attenuation table ..................................................................................................................C-5
C-3
LBOs based on attenuation ..........................................................................................................C-7
D
Backplane pin replacement
D-1
Backplane locations of METRAL™ pins ................................................................................... D-3
D-2
Metral™ pins .............................................................................................................................. D-3
E
Fiber labeling
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
List of tables
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
List of figures
1
Safety
1-1
Static control wrist strap ............................................................................................................... 1-5
2
Physical installation
2-1
Shelf mount rear cover kit 849001367 ......................................................................................... 2-3
2-2
Bay mount rear cover kit 849001060 ........................................................................................... 2-4
2-3
Center divider ............................................................................................................................... 2-6
2-4
Center divider with circuit packs installed. .................................................................................. 2-7
2-5
Alcatel-Lucent 1665 DMXtend mounting bracket positions - 23-Inch/19-Inch frame ............. 2-10
2-6
Fiber duct mounting ................................................................................................................... 2-11
2-7
Safety ground screw. .................................................................................................................. 2-12
2-8
Fiber spools ................................................................................................................................ 2-13
2-9
Power connection ....................................................................................................................... 2-14
3
Cable and fiber installation
3-1
Connector types and pinouts ........................................................................................................ 3-5
3-2
DS1/E1 cable connectors ............................................................................................................. 3-7
3-3
DS1/E1 cable routing to the right ................................................................................................. 3-8
3-4
DS1/E1 cable routing to the left ................................................................................................... 3-8
3-5
DS3/EC-1 cable connections ..................................................................................................... 3-15
3-6
DS3/EC-1 cable routing to the right .......................................................................................... 3-15
3-7
DS3/EC-1 cable routing to the left ............................................................................................ 3-16
3-8
DS1 and DS3 hybrid cable connections ..................................................................................... 3-31
3-9
DS1 and DS3 hybrid cable routing ........................................................................................... 3-31
3-10
10/100BASE-T/TX cable connections ....................................................................................... 3-37
3-11
10/100BASE-T cable routing ..................................................................................................... 3-37
3-12
IAO LAN/TCP-IP cable connection to rear of Alcatel-Lucent 1665 DMXtend ...................... 3-42
3-13
Modem cable connection .......................................................................................................... 3-45
3-14
Sync cable connections .............................................................................................................. 3-47
3-15
Office alarm cable connections .................................................................................................. 3-51
3-16
Office alarm cable routing .......................................................................................................... 3-51
x i i
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
List of figures
3-17
Miscellaneous discrete cable connection .................................................................................. 3-55
3-18
Miscellaneous discrete cable routing ........................................................................................ 3-55
3-19
Optical fiber routing .................................................................................................................. 3-60
4
Circuit pack installation
4-1
Power connections on Alcatel-Lucent 1665 DMXtend backplane .............................................. 4-4
5
Stand-alone node setup
6
Stand-alone installation testing
6-1
Alcatel-Lucent 1665 DMXtend shelf backplane ....................................................................... 6-54
6-2
Miscellaneous (environmental) discrete functions ................................................................... 6-57
7
Connecting adjacent network elements
8
WDMX setup and testing: integration procedures
A
Fiber cleaning
A-1
Cleaning the ferrule endface ........................................................................................................A-4
A-2
CLETOP cleaner ..........................................................................................................................A-5
A-3
Acceptability criteria for fiber cleaning .....................................................................................A-7
B
Pluggable Transmission Module (PTM) installation
B-1
Pluggable optics module ..............................................................................................................B-9
B-2
Module types ..............................................................................................................................B-10
B-3
Latch type 3 ...............................................................................................................................B-12
B-4
Latch type 4 ................................................................................................................................B-12
B-5
Electrical PTM routing ..............................................................................................................B-15
C
Installing fiber connectors and LBOs
C-1
LC-type connector ports on circuit pack ......................................................................................C-2
C-2
LC-type LBO ...............................................................................................................................C-3
C-3
LC-type LBO inserted into LC-type connector port ...................................................................C-3
C-4
Removing LC-type LBO from LC-type connector port ..............................................................C-4
C-5
LC-type fiber connector ...............................................................................................................C-8
C-6
LC-type fiber connection .............................................................................................................C-8
D
Backplane pin replacement
E
Fiber labeling
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
About this document
Purpose
This document provides the information and procedures necessary to install, self-test and
turn up Alcatel-Lucent 1665 Data Multiplexer Extend (Alcatel-Lucent 1665 DMXtend).
Reason for reissue
This document is being reissued to include information about new features and hardware
associated with R10.0 including:
•
Support for new circuit pack (LNW910): 1x10GE and 10xFE/GE with VLF
interworking
•
In-service LNW31 OC-48 to LNW603 OC-192 upgrade
•
Report alarms from sub-shelves via SNMP (single TID applications)
•
Revertive option on UPSR per STS-1 cross-connect
•
Remote test access over protected UPSR tributaries when the mains are equipped with
VLF packs
•
VT1.5 added to integrated test access capability
Intended audience
This installation manual is intended to provide individuals and customers the information
and procedures necessary to install, self-test and turn up the Alcatel-Lucent 1665
DMXtend system.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
About this document
This manual is not a service or operations manual. For any activities involving circuit turn-
up, regular maintenance, or trouble analysis, refer to:
•
Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) User Operations Guide,
365-372-325
•
Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Maintenance and Trouble
Clearing Guide, 365-372-326
\How to use this document
This manual is divided into the following sections with a brief description of the contents
of each major part/chapter/appendix:
About this document
This chapter describes the purpose, intended audience, reason for reissue, and
organization of this document. This section references related documentation and explains
how to order, make comments or recommend changes to this document.
Chapter 1, “Safety”
This chapter provides laser safety information and precautions.
Part I: “Physical and power installation”
Part I covers Chapters 2, 3, and 4. These sections covers the physical mounting of the
Alcatel-Lucent 1665 DMXtend shelf using the Horizontal Bay Mount. This section
includes the running and connecting of power cables, interconnecting cables, alarm
cables, and as required, external timing, communication cables, and covers initial circuit
pack installation (not seated). This section also provides the recommended checklist Table
I-2 “Installation checklist” to follow when installing a Alcatel-Lucent 1665 DMXtend
system. Use of the installation checklist is required to ensure a quality installation. All
completed tasks should be checked off and those not completed should be duly noted as to
the reason why. This checklist should be turned in as part of your job complete paperwork.
Chapter 2, “Physical installation”
This chapter provides equipment installation instructions for the Alcatel-Lucent 1665
DMXtend shelf using the horizontal bay mount configuration. The Alcatel-Lucent 1665
DMXtend shelves with the removable center divider can support either half width or full
width cards in the Main function slots.
Chapter 3, “Cable and fiber installation”
This chapter provides cabling instructions for the Alcatel-Lucent 1665 DMXtend shelf
using the horizontal bay mount configuration.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
xv
............................................................................................................................................................................................................................................................
About this document
Chapter 4, “Circuit pack installation”
This chapter provides information for verifying that the shelf is being supplied with the
proper power and provides instructions for circuit pack installation.
Part II: “Stand-alone installation tests”
Part II covers Chapters 5 and 6. These sections cover the initial Graphical User Interface
(GUI) or Craft Interface Terminal (CIT) software installation and turn-up testing on a new
Alcatel-Lucent 1665 DMXtend shelf. It is intended to verify correct electrical
DS1/DS3/FE cable wiring to the DSX panel or punch down block as well SONET fiber
routing to the LGX panel from the faceplates of installed packs. This section also the
recommended checklist “Installation checklist” to follow when installing a Alcatel-
Lucent 1665 Data Multiplexer Extend (Alcatel-Lucent 1665 DMXtend) system. Use of
the installation checklist is required to ensure a quality installation. All completed tasks
should be checked off and those not completed should be duly noted as to the reason why.
This checklist should be turned in as part of your job complete paperwork.
Chapter 5, “Stand-alone node setup”
This chapter provides procedures for initial Graphical User Interface (GUI) or Craft
Interface Terminal (CIT) software installation and circuit packs provided via work order.
Also, the use of the Graphical User Interface (GUI) or Craft Interface Terminal (CIT).
Chapter 6, “Stand-alone installation testing”
This chapter is to verify proper transmission cabling installation and R10.0 functionality
as well as the associated functionality of the Alcatel-Lucent 1665 DMXtend shelf.
Part III: “Network turn-up and testing”
Part III covers fiber connections between nodes in a ring. It is not intended to replace
acceptance test procedures. This section also provides the recommended checklist
“Installation checklist” to follow when installing a Alcatel-Lucent 1665 DMXtend system.
Use of the installation checklist is required to ensure a quality installation. All completed
tasks should be checked off and those not completed should be duly noted as to the reason
why. This checklist should be turned in as part of your job complete paperwork.
Chapter 7, “Connecting adjacent network elements”
This chapter is used to make fiber connections between nodes in a ring. It is not intended
to replace acceptance test procedures.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
About this document
Chapter 8, “WDMX setup and testing: integration procedures”
This chapter is used to verify WDMX connectivity between Alcatel-Lucent 1665 Data
Multiplexer Extend (Alcatel-Lucent 1665 DMXtend) nodes. The chapter includes the
LNW785 8 channel Optical Multiplexer Demultiplexer (OMD) circuit pack. It is not
intended to replace acceptance test procedures.
Part IV: “Miscellaneous detailed installation procedure and reference material”
Part IV provides supplementary information that is useful when installing the Alcatel-
Lucent 1665 DMXtend system and using this Installation Manual.
Appendix A, “Fiber cleaning”
This appendix describes the Alcatel-Lucent recommended method for the cleaning and
inspection of optical connectors using specific tools and materials that have been proven
to be effective in the assembly and testing of optical transmission equipment.
Appendix B, “Pluggable Transmission Module (PTM) installation”
This appendix provides examples of PTM installation.
Appendix C, “Installing fiber connectors and LBOs”
This appendix provides procedures for installing and removing the types of Line Build
Out units (LBOs) and fiber connectors onto input and output ports found on the Alcatel-
Lucent 1665 DMXtend circuit packs.
Appendix D, “Backplane pin replacement”
This appendix provides information and the procedures used when a pin or blade on the
Alcatel-Lucent 1665 DMXtend backplane has been bent or broken.
Appendix E, “Fiber labeling”
This appendix describes the labeling of the fiber.
Glossary
The Glossary provides definitions for telecommunication acronyms and terms.
Index
The Index supplies users with specific subjects and corresponding page numbers to find
necessary information.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
xvii
............................................................................................................................................................................................................................................................
About this document
Safety information
This information product contains hazard statements for your safety. Hazard statements
are given at points where safety consequences to personnel, equipment, and operation may
exist. Failure to follow these statements may result in serious consequences.
Safety precautions
Adhere to the following safety precautions:
•
Electrostatic discharge (ESD)
You must be properly grounded when making contact with the Alcatel-Lucent 1665
DMXtend frame and handling circuit packs, disk drives, and tapes. Wrist strap ground
cords should be routinely tested for the minimum 1-megohm resistance.
•
Plug-in storage
Circuit packs should be stored in static-safe packaging or in a grounded cabinet.
For additional safety precautions, please see the Alcatel-Lucent 1665 Data Multiplexer
Extend (DMXtend) User Operations Guide, 365-372-325.
Conventions used
Italic typeface denotes a particular product line or information product.
Arial Bold typeface signifies a window, section, command or parameter used with the
Graphical User Interface
Helvetica typeface indicates a faceplate or Alcatel-Lucent 1665 DMXtend label
designation, as in the ACTIVE LED on a circuit pack.
Courier Bold indicates a TL1 command typed in a terminal window by the user, as in
act-user:LT-DMXTEND:LUC01:ctag::DMXTND2.5G;
Courier typeface indicates the system or PC response to a command.
Alcatel-Lucent 1665 DMXtend Documentation Set
The following table lists the documents included in the Alcatel-Lucent 1665 DMXtend
documentation set.
CAUTION
Laser Safety
When connecting fiber loops between the IN and OUT ports on optical circuit
packs, always connect to the IN port first and then the OUT port. This will
prevent any optical radiation from being present at the fiber end.For more
detailed information and safety precautions, see Chapter 1, “Safety”.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
About this document
Table 1
Alcatel-Lucent 1665 DMXtend documentation set
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support) for contact
information.
Document number/Comcode
Title
365-372-330
WaveStar® CIT User Guide
365-372-324R10.0
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Applications and Planning Guide
365-372-325R10.0
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) User Operations Guide
365-372-326R10.0
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Alarm Messages and Trouble Clearing
Guide
365-372-327R10.0
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Installation Manual
365-372-328R10.0
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) TL1 Message Details
ED8C951-10
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Engineering and Ordering Information
ED8C951-20
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Interconnect Information
109789164
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Release 10.0.0 Customer Release Notes
(PDF)
109789172
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Release 10.0.0 Customer Release Notes
(CD-ROM)
109789180
Alcatel-Lucent 1665 Data Multiplexer Extend
(DMXtend) Release 10.0.0 Eletronic Documentation
Library
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
xix
............................................................................................................................................................................................................................................................
About this document
How to order
To order Alcatel-Lucent documents contact your local sales representative or use Online
Customer Support (OLCS) (https://support.alcatel-lucent.com).
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments) or email your comments to the Comments Hotline
([email protected]).
Packaging collection and recovery requirements
Countries, states, localities, or other jurisdictions may require that systems be established
for the return and/or collection of packaging waste from the consumer, or other end user,
or from the waste stream. Additionally, reuse, recovery, and/or recycling targets for the
return and/or collection of the packaging waste may be established.
For more information regarding collection and recovery of packaging and packaging
waste within specific jurisdictions, please contact the Alcatel-Lucent Services -
Environmental Health and Safety organization.
Material content compliance
European Union RoHS
European Union (EU) Directive 2002/95/EC, Restriction of the use of certain Hazardous
Substances” (RoHS), restricts the use of lead, mercury, cadmium, hexavalent
chromium, and certain flame retardants in electrical and electronic equipment. This
Directive applies to electrical and electronic products placed on the EU market after 1 July
2006, with various exemptions, including an exemption for lead solder in network
infrastructure equipment. Alcatel-Lucent products shipped to the EU after 1 July 2006
comply with the EU RoHS Directive.
China RoHS
The Peoples Republic of China Ministry of Information Industry has published a
regulation (Order #39) and associated standards regarding restrictions on hazardous
substances (China RoHS). Currently, the legislation requires all Electronic and
Information Products (EIP) to comply with certain labeling and documentation
requirements. Alcatel-Lucent products manufactured on or after 1 March 2007, that are
intended for sale to customers in the China market, comply with these requirements.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
About this document
In accordance with the People’s Republic of China Electronic Industry Standard “Marking
for the Control of Pollution Caused by Electronic Information Product” (SJ/T11364-
2006), customers may access Alcatel-Lucent’s Hazardous Substances Table information
at either of the following two URLs (for the convenience of our diverse customer base):
•
Access via the Alcatel-Lucent Corporate website at: http://www.alcatel-
sbell.com.cn/live/home/index.jsp (http://www.alcatel-sbell.com.cn/
•
Access via the Alcatel Shanghai Bell website at: http://www.alcatel-
sbell.com.cn/wwwroot/images/upload/private/1/media/China-RoHS-HST-3.1.pdf
(http://www.alcatel-sbell.com.cn/wwwroot/images/upload/
Recycling/take-back/disposal of product
Electronic products bearing or referencing the symbols shown below shall be collected
and treated at the end of their useful life, in compliance with applicable European Union
and other local legislation. They shall not be disposed of as part of unsorted municipal
waste. Due to materials that may be contained in the product and batteries, such as heavy
metals, the environment and human health may be negatively impacted as a result of
inappropriate disposal.
Note:
For electronic products put on the market in the European Union, a solid bar
under the crossed-out wheeled bin indicates that the product was put on the market.
Moreover, in compliance with legal requirements and contractual agreements, where
applicable, Alcatel-Lucent will offer to provide for the collection and treatment of Alcatel-
Lucent products bearing the logo at the end of their useful life, or products. For
information regarding take-back, recycling, or disposal of equipment by Alcatel-Lucent or
for equipment take-back requests, visit the Alcatel-Lucent Take-Back web page
(http://www.alcatel-lucent.com/product_takeback) or contact Alcatel-Lucent Take-Back
Support ([email protected]). For technical information on product treatment,
consult the Alcatel-Lucent Recycling Information web page.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
1
Safety
Overview
Purpose
This chapter provides important safety instructions for the Alcatel-Lucent 1665 Data
Multiplexer Extend (Alcatel-Lucent 1665 DMXtend).
Contents
This appendix provides information on the following topics:
Laser safety
System design
The Alcatel-Lucent system complies with FDA/CDRH 21 CFR 1040.10 and 1040.11 as a
Class I and with IEC 60825-1 as a Class 1 Optical Fiber Telecommunication laser product.
The system has been designed to ensure that the operating personnel is not endangered by
laser radiation during normal system operation. The safety measures specified in the Food
and Drug Administration’s Center for Devices and Radiological Health (FDA/CDRH)
regulations and the international standards IEC-60825 or DIN/EN 60825 are met. Please
also see “Laser product classification” (p. 1-9).
Laser safety
1-1
Electrostatic discharge ESD considerations
1-3
Laser product classification
1-9
Alcatel-Lucent 1665 DMXtend optical specifications
1-11
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
Potential sources of danger
Beware of the following potential sources of danger which will remain despite all safety
measures taken:
•
Laser radiation can cause damage to the skin and eyes.
•
Laser radiation from optical transmission systems is in a wavelength range that is
invisible to the human eye.
Laser warning labels
The laser warning labels indicate either only the laser class or both the laser class and the
maximum output power of laser radiation. The following figure shows different types of
laser warning labels and their characteristics.
CAUTION
Do not view directly
with optical
instruments.
CLASS 1M INVISIBLE
LASER RADIATION
WHEN OPEN
AND FIBER
DISCONNECTED.
ATTENTION
RAYONNEMENT
LASER DE CLASSE
1M INVISIBLE
LORSQUE
L’APPAREIL EST
OUVERT ET QUE
LA FIBRE EST
DÉCONNECT E.
Ne pas regarder
directement au moyen
d’un instrument optique.
É
848950572
HAZARD
LEVEL
1M
1
2
3
CLASS 1 LASER
PRODUCT
DANGER
INVISIBLE LASER RADIATION
WHEN OPEN AND FIBER
DISCONNECTED
Avoid direct exposure to beam
Do not view beam directly with
optical instruments
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-3
............................................................................................................................................................................................................................................................
Safety
Legend
1. Laser symbol.
2. Laser classification label. This label may show only the laser class or both the laser
class and the maximum output power.
3. Laser warning label.
Laser safety instructions
Observe the following instructions to avoid exposing yourself and others to risk.
•
Read the relevant descriptions in the manuals before taking equipment into operation
or carrying out any installation and maintenance work on the optical port units, and
follow the instructions. Ignoring the instructions can result in exposure to dangerous
radiation.
•
Do not view directly into the laser beam with optical instruments such as a fiber
microscope, because viewing of laser emission in excess of Class 1 limits significantly
increases the risk of eye damage.
•
Never look into the end of an exposed fiber or an open connector as long as the optical
source is still switched on.
•
Ensure that the optical source is switched off before disconnecting optical fiber
connectors.
•
In the event of doubt, check that the optical source is switched off by measuring with
an optical power meter.
•
When connecting fiber loops between the IN and OUT ports on optical circuit packs,
always connect to the IN port first and then the OUT port. This will prevent any optical
radiation from being present at the fiber end.
Electrostatic discharge ESD considerations
ESD precautions
Industry experience has shown that all integrated circuit packs can be damaged by static
electricity that builds up on work surfaces and personnel. The static charges are
produced by various charging effects of movement and contact with other objects. Dry air
allows greater static charges to accumulate. Higher potentials are measured in areas
with low relative humidity, but potentials high enough to cause damage can occur
anywhere.
CAUTION
ESD hazard
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
In order to prevent damage by electrostatic discharge the following precautions should be
observed when handling circuit packs:
•
Assume all circuit packs contain solid state electronic components that can be
damaged by ESD.
•
When handling circuit packs (storing, inserting, removing, etc.) or when working on
the backplane, always wear a grounded wrist strap such as the one shown in
Figure 1-1, “Static control wrist strap” (p. 1-5) or wear a heel strap and stand on a
grounded, static dissipating floor mat. If a static dissipating floor mat is used, be sure
that it is clean to ensure a good discharge path.
•
Handle all circuit packs by the faceplate or latch and by the top and bottom outermost
edges. Never touch the components, conductors, or connector pins.
•
Observe warning labels on bags and cartons. Whenever possible, do not remove circuit
packs from antistatic packaging until ready to insert them into slots.
•
If possible, open all circuit packs at a static safe work position, using properly
grounded wrist straps and static dissipating table mats. If a static dissipating floor mat
is used, be sure that it is clean to ensure a good discharge path.
•
Always store and transport circuit packs in static safe packaging. Shielding is not
required unless specified.
•
Keep all static generating materials such as food wrappers, plastics, and styrofoam
containers away from all circuit packs. Upon removal from bay, immediately put
circuit packs into static safe packages.
•
Whenever possible, maintain relative humidity above 20 percent.
To reduce the possibility of ESD damage, assemblies are equipped with grounding jacks
to enable personnel to ground themselves using wrist straps [Figure 1-1, “Static control
wrist strap” (p. 1-5)] while handling circuit packs or working on an assembly. The jacks
for connection of wrist straps are located at the lower right-hand corner of each assembly
and are labeled. When grounding jacks are not provided, an alligator clip adapter enables
connection to bay frame ground.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-5
............................................................................................................................................................................................................................................................
Safety
Figure 1-1
Static control wrist strap
TO
GROUND
CONNECTION
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
IMPORTANT SAFETY INSTRUCTIONS
READ AND UNDERSTAND ALL INSTRUCTIONS
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying this product.
When installing, operating, or maintaining this equipment, basic safety
precautions should always be followed to reduce the risk of fire, electric shock, and injury
to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on this product.
3. This product should be only operated from the type of power sources indicated on the
marking label.
4. Connect this product only to the type of power sources recommended by Alcatel-
Lucent. For information on the powering instructions, consult the Installation Manual.
5. This equipment is suitable for mounting on a concrete or other noncombustible surface
only.
6. For information on proper mounting instructions, consult the Installation Manual.
7. Install only equipment identified in the Installation Manual. Use of other equipment
may result in improper connection of circuitry leading to fire or injury to persons.
8. All metallic telecommunication interfaces should not leave the building premises
unless connected to telecommunication devices providing primary and secondary
protection, as applicable.
9. Do not use this product near water, for example, in a wet basement.
10. Do not place this product on an unstable cart, stand or table. The product may fall,
causing serious damage to the product.
11. Use caution when installing or modifying telecommunications lines.
12. Never install telecommunications wiring during a lightning storm.
13. Never install telecommunications connections in wet locations.
14. Never touch uninsulated telecommunications wires or terminals unless the
telecommunications line has been disconnected at the network interface.
15. Never touch uninsulated wiring or terminals carrying direct current or ringing current,
or leave this wiring exposed. Protect and tape uninsulated wiring and terminals to
avoid risk of fire, electric shock, and injury to service personnel.
16. Never push objects of any kind into this product through slots as they may touch
dangerous voltage points or short out parts that could result in a risk of fire or electrical
shock. Never spill liquids of any kind on the product.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-7
............................................................................................................................................................................................................................................................
Safety
17. Slots and openings in the unit are provided for ventilation, to protect it from
overheating, and these openings must not be blocked or covered. This product should
not be placed in a built-in installation unless proper ventilation is provided.
18. To reduce the risk of an electrical shock, do not disassemble this product. Service
should be performed by trained personnel only. Opening or removing covers and/or
circuit boards may expose you to dangerous voltages or other risks. Incorrect
reassembly can cause electrical shock when the unit is subsequently used.
19. Some of the Alcatel-Lucent 1665 Data Multiplexer Extend (Alcatel-Lucent 1665
DMXtend) hardware modules contain FDA/CDRH Class I/IEC Class 1 single-mode
laser products that are enclosed lightwave transmission systems. Under normal
operating conditions, lightwave transmission systems are completely enclosed;
nonetheless, the following precautions must be observed because of the potential for
eye damage:
•
Do not disconnect any lightwave cable or splice and stare into the optical
connectors terminating the cables.
•
Lightwave/lightguide operations should not be performed by a technician who has
not satisfactorily completed an approved training course.
•
Do not use optical instruments such as an eye loupe to view a fiber or unterminated
connector.
•
More information about laser safety can be found in the Installation Manual.
20. For a unit intended to be powered from –48 V dc voltage sources, read and understand
the following:
•
To be powered only by Safety Extra Low Voltage (SELV) -48 V dc Sources.
•
Disconnect up to Two (2) power supply connections when removing power from
the system.
•
This equipment must be provided with a readily accessible disconnect device as
part of the building installation.
•
Ensure that there is no exposed wire when the input power cables are connected to
the unit.
•
Installation must include an independent frame ground drop to building ground.
See Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) User Operations
Guide, 365-372-325
This symbol is marked on the product,
adjacent to the ground (earth) area for the
connection of the ground (earth) conductor.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
•
This Equipment is to be Installed Only in Restricted Access Areas on Business and
Customer Premises Applications in Accordance with Articles 110-16, 110-17, and
110-18 of the National Electrical Code, ANSI/NFPA No. 70. Other Installations
Exempt from the Enforcement of the National Electrical Code May Be Engineered
According to the Accepted Practices of the Local Telecommunications Utility.
21. For a unit intended to be powered from 100-120/200-240 V ac voltage sources, read
and understand the following:
•
Unplug this product from the wall outlet before cleaning. Do not use liquid
cleaners or aerosol cleaners. Use a damp cloth for cleaning.
•
Do not staple or otherwise attach the power supply cord to the building surfaces.
•
Do not overload wall outlets and extension cords as this can result in the risk of fire
or electric shock.
•
The socket outlet should be installed near the equipment and should be readily
accessible.
•
This product is equipped with a three-wire grounding type plug, a plug having a
third (grounding) pin. This plug is intended to fit only into a grounding type power
outlet. This is a safety feature. If you are unable to insert the plug into the outlet,
contact your electrician to replace your obsolete outlet. Do not defeat the safety
purpose of the grounding type plug. Do not use a 3-to-2-prong adapter at the
receptacle. Use of this type adapter may result in risk of electrical shock and/or
damage to this product.
•
Do not allow anything to rest on the power cord. Do not locate this product where
the cord may be abused by persons walking on it.
•
Unplug this product from the wall outlet and refer servicing to qualified service
personnel under the following conditions:
a.
When the powers supply cord or plug is damaged or frayed.
b. If liquid has been spilled into the product.
c.
If the product has been exposed to rain or water.
d. If the product does not operate normally by following the operating instructions.
Adjust only those controls that are covered by the operating instructions because
improper adjustment of other controls may result in damage and will often require
extensive work by qualified technician to restore the product to normal operation.
e.
If the product has been dropped or the cabinet has been damaged.
f.
If the product exhibits a distinct change in performance.
SAVE THESE INSTRUCTIONS
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-9
............................................................................................................................................................................................................................................................
Safety
Laser product classification
Standards compliance
The product complies with both IEC standards and the Food and Drug Administration’s
Center for Devices and Radiological Health (FDA/ CDRH) regulations.
FDA/CDRH regulations
Laser products are classified in accordance with the FDA/CDRH - 21 CFR 1010 and 1040.
The classification scheme is based on the ability of the laser emission to cause injury to
eye or skin during normal operating conditions.
In the United States, lasers and laser systems in the infrared wavelength range (greater
than 700 nm) are assigned to one of the following classes:
•
Class I,
•
Class IIIb, or
•
Class IV.
Laser classification is dependent upon operating wavelength, output power and fiber
modefield diameter (core diameter).
IEC requirements
The International Electro-Technical Commission (IEC) establishes standards for the
electrical and electronic industries. IEC-60825 has been established for the worldwide
safety of laser products.
According to the IEC classification, lasers and laser systems in the infrared wavelength
range (greater than 700 nm) are assigned to one of the following classes:
•
Class 1,
•
Class 3A,
•
Class 3B, or
•
Class 4.
There are some major differences between the FDA/CDRH regulations and IEC:
1. The Accessible Emission Limits (AEL) are different.
2. Class 3A applies to all wavelengths.
3. Class 3B requires strict engineering controls.
4. Classification is under single fault conditions.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
Laser classes
The maximum output power of laser radiation depends on the type of laser diode used.
The international standards IEC-60825 or DIN/EN 60825 define the maximum output
power of laser radiation for each laser class in accordance with the wavelength.
Table 1-1
Laser classes
Hazard level assignment
Hazard level refers to the potential hazard from laser emission at any location in an end-
to-end optical fiber communication system that may be accessible during service or in the
event of a failure. The assignment of hazard level uses the AELs for the classes.
Hazard levels for optical transmission equipment are assigned in either of the following
two ways:
•
Actual output power from the connector or fiber cut.
•
If automatic power reduction is used, output power at the connector or fiber cut at one
second after automatic power reduction takes place provided that maximum output
and restart conditions are met.
Classification of optical telecommunication equipment
Optical telecommunication equipment is generally classified as IEC Class 1 or
FDA/CDRH Class I, because under normal operating conditions, the transmitter ports
terminate on optical fiber connectors. These are covered by a front panel to ensure
protection against emissions from any energized, unterminated transmitter. The circuit
packs themselves, however, may be IEC Class 1 or 3A or FDA/CDRH Class I or IIIb.
Laser class
Wavelength
Maximum output power
of laser radiation
1
1310 nm
8.85 mW
1550 nm
10 mW
3A
1310 nm
24 mW
1550 nm
50 mW
3B
1310 nm
0.5 W
1550 nm
0.5 W
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-11
............................................................................................................................................................................................................................................................
Safety
Alcatel-Lucent 1665 DMXtend optical specifications
Overview
Table 1-2 provides the optical specifications for Alcatel-Lucent 1665 DMXtend internal
laser circuit packs; these packs do not use PTMs.
Table 1-2
Alcatel-Lucent 1665 DMXtend optical circuit pack laser safety
specifications
Laser Circuit Pack
Code
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min Rcv
Pwr (dBm)
Fiber
Type (µm)
Conn
Type
FDA Class/
IEC Class
LNW31 OC-48
1310
0.0
0.0/-18.0
SM (9)
LC
I(LN50)/1
LNW38 OC-12
1310
-8.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
LNW40 OC-3
1310
-8.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
LNW51 OC-12
1310
+2.0
-7.0/-30.5
SM (9)
LC
I(LN50)/1
LNW52 OC-48
1310
+3.0
-9.0/-27.0
SM (9)
LC
I(LN50)/1
LNW601 OC-3
1310
0.0
0.0/-34.0
SM (9)
LC
I(LN50)/1
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
Table 1-3 shows the pluggable transmission module (PTM) laser safety specifications and
the supported circuit packs. The following Class 1 SFP/XFP transceivers are Alcatel-
Lucent approved.
Table 1-3
Alcatel-Lucent 1665 DMXtend optical PTM laser safety specifications
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
100BASE-
ZX-I1
LNW74
LNW87
LNW170
1550
+2.0
-8.0/-31.0
SM (9)
LC
I(LN50)/1
100BASE-
LX-I1
LNW63
LNW64
LNW74
LNW87
LNW170
LNW910
1310
-8.0
-8.0/-25.0
SM (9)
LC
I(LN50)/1
100BASE-
FX-I1
LNW74
LNW87
LNW170
1310
-14.0
-14.0/-29.0
MM (50
and 62.5)
LC
I(LN50)/1
1000BASE-
ZX-I1
LNW63
LNW64
LNW87
LNW170
LNW910
1550
+5.0
0.0/-22.5
SM (9)
LC
I(LN50)/1
ESCON-
MM-I1
LNW73/73C
1310
-14.0
-14.4/-29.0
MM (50
and 62.5)
LC
I(LN50)/1
GE-
1X2XFC-
LX-I1
LNW63
LNW64
LNW73/73C
LNW87
LNW170
LNW705
LNW910
1310
-3.0
-3.0/-19.0
SM (9)
LC
I(LN50)/1
GE-
1X2XFC-
SX-I1
LNW63
LNW64
LNW73/73C
LNW87
LNW170
LNW705
LNW910
850
-2.5
0.0/-17.0
MM (50
and 62.5)
LC
I(LN50)/1
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-13
............................................................................................................................................................................................................................................................
Safety
BASE-TC1-
electrical
LNW63
LNW64
LNW87
LNW170
NA
NA
NA
NA
RJ45
NA
SGEMEC1
LNW910
NA
NA
NA
NA
RJ45
NA
X10GMC2
LNW910
1310
-1.0
0.5/-11.0
SM (9)
LC
I(LN50)/1
X10GMC4
LNW910
1550
+3.0
-1.0/-14.0
SM (9)
LC
I(LN50)/1
X10GMC5
LNW910
1550
+4.0
-7.0/-24.0
SM (9)
LC
I(LN50)/1
OC3SR1-I1
(S155I2)
LNW37
LNW45
LNW55
LNW84
LNW302
LNW705
1310
-8.0
-8.0/-23.0
SM (9)
LC
I(LN50)/1
OC3IR1-I1
LNW37
LNW45
LNW55
LNW84
LNW302
LNW705
1310
-8.0
-15.0/-28.0
SM (9)
LC
I(LN50)/1
OC3LR1-I1
LNW37
LNW45
LNW55
LNW84
LNW302
LNW705
1310
-0.0
-10.0/-34.0
SM (9)
LC
I(LN50)/1
OC3X12X48
IR1-I1
LNW55
LNW84
1310
(OC-3)
0.0
-10.0/-18.0
SM (9)
LC
I(LN50)/1
1310
(OC-12/48)
0.0
0.0/-18.0
OC3X12X48
LR1-I1
LNW55
LNW84
1310
(OC-3)
+3.0
-15.0/-2.0
SM (9)
LC
I(LN50)/1
1310
(OC-12/48)
+3.0
-9.0/-2.0
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
OC12IR1-I1
LNW49
LNW55
LNW84
LNW382
LNW705
1310
-8.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
OC12LR1-I1
LNW49
LNW55
LNW84
LNW382
LNW705
1310
+2.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
OC12LR2-I1
LNW49
LNW55
LNW84
LNW382
LNW705
1550
+2.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C47EL
LNW37
LNW45
LNW49
LNW55
LNW84
1471
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C49EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1491
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C51EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1511
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C53EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1531
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-15
............................................................................................................................................................................................................................................................
Safety
S622C55EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1551
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C57EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1571
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C59EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1591
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
S622C61EL
LNW37
LNW45
LNW49
LNW55
LNW84
LNW705
1611
+5.0
-8.0/-28.0
SM (9)
LC
I(LN50)/1
OC48SR1-I1
LNW41
LNW55
LNW62
LNW84
LNW402
LNW705
1310
-3.0
-3.0/-18.0
SM (9)
LC
I(LN50)/1
OC48LR1-I1
LNW41
LNW55
LNW62
LNW84
LNW402
LNW705
1310
+3.0
-9.0/-27.0
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
OC48LR2-I1
LNW41
LNW55
LNW62
LNW84
LNW402
LNW705
1550
+3.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D23C6
LNW41
LNW55
LNW62
LNW84
LNW402
1558.983
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D25C6
LNW41
LNW55
LNW62
LNW84
LNW402
1557.363
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D27C6
LNW41
LNW55
LNW62
LNW84
LNW402
1555.747
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D31C6
LNW41
LNW55
LNW62
LNW84
LNW402
1552.524
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D33C6
LNW41
LNW55
LNW62
LNW84
LNW402
1550.918
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D35C6
LNW41
LNW55
LNW62
LNW84
LNW402
1549.315
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-17
............................................................................................................................................................................................................................................................
Safety
S2D37C6
LNW41
LNW55
LNW62
LNW84
LNW402
1547.715
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D45C6
LNW41
LNW55
LNW62
LNW84
LNW402
1541.349
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D47C6
LNW41
LNW55
LNW62
LNW84
LNW402
1539.766
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D49C6
LNW41
LNW55
LNW62
LNW84
LNW402
1538.186
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D53C6
LNW41
LNW55
LNW62
LNW84
LNW402
1535.036
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D55C6
LNW41
LNW55
LNW62
LNW84
LNW402
1533.465
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
S2D59C6
LNW41
LNW55
LNW62
LNW84
LNW402
1530.334
+4.0
-9.0/-28.0
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
S2G7C47LI
LNW41
LNW55
LNW62
LNW84
LNW402
1471
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C49LI
LNW41
LNW55
LNW62
LNW84
LNW402
1491
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C51LI
LNW41
LNW55
LNW62
LNW84
LNW402
1511
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C53LI
LNW41
LNW55
LNW62
LNW84
LNW402
1531
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C55LI
LNW41
LNW55
LNW62
LNW84
LNW402
1551
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C57LI
LNW41
LNW55
LNW62
LNW84
LNW402
1571
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
S2G7C59LI
LNW41
LNW55
LNW62
LNW84
LNW402
1591
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-19
............................................................................................................................................................................................................................................................
Safety
S2G7C61LI
LNW41
LNW55
LNW62
LNW84
LNW402
1611
+5.0
-8.0/NA
SM (9)
LC
I(LN50)/1
OC192IR2-
C1
LNW141
LNW603
LNW705
1550
+2.0
-1.0/-14.0
SM (9)
LC
I(LN50)/1
OC192IR2-
I1
LNW141
LNW705
1550
+2.0
-7.0/-24.0
SM (9)
LC
I(LN50)/1
OC192LR2-
C1
LNW141
LNW603
1550
+4.0
-7.0/-24.0
SM (9)
LC
I(LN50)/1
OC192SR1-
C1
LNW141
LNW603
1310
-1.0
-1.0/-11.0
SM (9)
LC
I(LN50)/1
X10G21C5
LNW141
1560.606
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G22C5
LNW141
1559.794
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G23C5
LNW141
1558.983
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G24C5
LNW141
1558.173
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G25C5
LNW141
1557.363
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G26C5
LNW141
1556.555
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G27C5
LNW141
1555.747
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
X10G28C5
LNW141
1554.940
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G31C5
LNW141
1552.524
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G33C5
LNW141
1550.918
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G35C5
LNW141
1549.315
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G37C5
LNW141
1547.715
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G45C5
LNW141
1541.349
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G47C5
LNW141
1539.766
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G49C5
LNW141
1538.186
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G52C5
LNW141
1535.822
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G53C5
LNW141
LNW603
1535.036
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G54C5
LNW141
1534.250
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G55C5
LNW141
1533.465
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
1-21
............................................................................................................................................................................................................................................................
Safety
Table 1-4
Dispersion-limited receiver sensitivity for OC-192 DWDM PTMs
X10G56C5
LNW141
LNW603
1532.681
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G57C5
LNW141
1531.898
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G58C5
LNW141
LNW603
1531.116
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
X10G59C5
LNW141
1530.334
+3.0
-
8.0/Table 1
-4
SM (9)
LC
I(LN50)/1
Module
Code
Supported
Circuit
Pack(s)
Wavelength
(nm)
Maximum
Out Pwr
(dBm)
Max/Min
Rcv Pwr
(dBm)
Fiber
Type
(µm)
Conn
Type
FDA
Class/
IEC Class
Data Rate
Receiver
Sensitivity
0 ps/nm
dispersion
Receiver
Sensitivity
1300 ps/nm
dispersion
Receiver
Sensitivity
1600 ps/nm
dispersion
9.9 Gb/s
-24.0 dBm
-22.0 dBm
NA
10.7-11.1 Gb/s with
Forward Error
Correction (FEC)
enabled
-27.0 dBm
NA
-25.0 dBm
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Safety
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Part I: Physical and power
installation
Overview
Introduction
Part I covers the physical mounting of the Alcatel-Lucent 1665 Data Multiplexer Extend
(Alcatel-Lucent 1665 DMXtend) shelf using the Horizontal Bay Mount. This section
includes running and connecting power cables, interconnecting cables, alarm cables, and
as required, external timing, and communication cables. Initial circuit pack installation
(not seated) is also included.
Part I provides a recommended checklist Table I-2 “Installation checklist” to follow when
installing Alcatel-Lucent 1665 DMXtend. Use of the installation checklist is required to
ensure a quality installation. All completed tasks should be checked off and those not
completed should be duly noted as to the reason why. This checklist should be turned in as
part of your job complete paperwork.
Note:
The Alcatel-Lucent 1665 DMXtend shelf does not require the installation of
an additional fan shelf since the fan unit is integral to the shelf itself.
Contents
This part includes the following chapters:
Chapter 2, “Physical installation”
Chapter 3, “Cable and fiber installation”
Chapter 4, “Circuit pack installation”
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical and power installation
Tools, test equipment and accessories
This section lists the tools, test equipment and accessories needed to perform all the
procedures in this installation manual.
Listed below are the required tools, test equipment and accessories.
Qty.
Description
Comments
1
19" Mounting Brackets
849011804
The 19" mounting brackets (C849011804) must be
ordered separately and are required to install the
Alcatel-Lucent 1665 DMXtend in a 19" bayframe.
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is (are)
required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit breakers
to the OFF position.
1
Thomas & Betts* R-5648B
Crimping Tool
The crimping tool and wire stripper are only required
if installing DS3/EC1 cables. The replacement
cassette is for the wire stripper tool.
2
Paladin† Coaxial Wire
Stripper R-5648B
Replacement Paladin†
Cassette R-5648B D5
1
Wire-Wrap Gun
R-4496A
The wire-wrap gun is required for terminating DS1/E1
cable and must be able to accommodate 24 gauge
wire.
1
ESD Wrist Strap
R-4987C
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
1
Torque Wrench
R-5952
A torque wrench (50-250 IN-LBS) is used when
tightening the Alcatel-Lucent 1665 DMXtend shelf
to the frame. It is also used when reattaching the
mounting brackets to the Alcatel-Lucent 1665
DMXtend shelf.
1
Metric & Inch Series Tool
Set
R-6001
Because some of our Optical Networking Products
(also know as Transport) may have some metric
fasteners, please ensure that the proper metric tools are
available.
1
Multimeter (Optional)
ITE-6379C
The voltmeter must be capable of measuring DC
voltage in the 40 to 60 volt range. The use of the
voltmeter is optional since the shelf will alarm or shut
down if the proper voltage is not supplied.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
I-3
............................................................................................................................................................................................................................................................
Physical and power installation
1
Ohmmeter
ITE-6379C
An ohmmeter is required to verify that the Alcatel-
Lucent 1665 DMXtend is properly grounded.
1
DS1/E1 Error Rate Test Set
ITE-7113
A DS1/E1 error rate test set is required for testing of
DS1/E1 cabling. A T-BERD 2209 or equivalent is
recommended.
1
DS3/EC1 Error Rate Test
Set
ITE-7113
A DS3/EC1 error rate test set is required for testing of
DS3/EC1 cabling. A T-BERD 209 or equivalent is
recommended.
1
Optical Test Set (Optional)
A Optical test set is required for testing of low speed
optics OC3/12/48. An Omniber 718 or equivalent is
recommended.
2 or 3
LC-type Optical Fiber
Jumper ITE-7169
(108918269)
Two optical fiber jumpers with LC type connectors are
required to optically loop the Alcatel-Lucent 1665
DMXtend shelf for test purposes. In addition, for
shelves containing optical circuit packs in any of the
function unit slots, a single optical fiber jumper is
required for testing of the individual ports.
1
15-dB LC-type LBO ITE-
7196 (108279480)
LBOs are only required when optically looping the
Alcatel-Lucent 1665 DMXtend shelves containing
optical circuit packs in any of the function unit slots; a
single 15-dB LBO is required for testing of the
individual ports
Noyes OFS 300-200X
Optical Fiber Scope
ITE-7129
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the optical fiber scope may not be needed
2.5mm Universal adapter
cap ITE-7129 D1
For use with the Noyes OFS 300-200X Optical Fiber
Scope
1.25mm Universal adapter
cap ITE-7129 D2
Noyes VFS-1 ITE-7187
Video Fiber Scope1
This equipment may not be necessary at all locations.
It is to be used when the ports need to be verified for
cleanliness. If care is exercised when cleaning fibers,
the video scope may not be needed
Individual presaturated
alcohol wipes ITE-7136
99% pure isopropyl alcohol
Qty.
Description
Comments
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical and power installation
PC and cable requirements for WaveStar® CIT
This section lists the required equipment needed to run the WaveStar® CIT software with
the Alcatel-Lucent 1665 DMXtend.
1
CLETOP Cleaning
Cassette ITE-7137
Type A Reel
1
CLETOP Cleaning
Cassette Replacement Reel
ITE-7137 D1
Type A Reel
Luminex Stick port
cleaners ITE-7134 & ITE-
7135
1.25 mm and 2.5 mm sizes
Luminex Cloth R-6033
5.5” x 5.5”
Notes:
* Registered trademark of Thomas & Betts Corporation
† Registered trademark of Paladin Corporation.
Qty.
Description
Comments
Quantity
Description
Comments
1
Personal Computer
(PC)
See PC minimum requirements.
1
RS-232 Interface
Cable
8-ft. long RJ45 to 9-pin D-sub serial
cable (Comcode 848748869)
1
RJ45 to RJ45 Cross-
over Cable
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
I-5
............................................................................................................................................................................................................................................................
Physical and power installation
PC minimum requirements
It is anticipated that most customers will dedicate a laptop or personal computer (PC) to
run the WaveStar® CIT software. However, any properly configured computer will also
suffice. The following table shows the requirements for the computer.
Note:
Windows Vista is not supported.
Table I-1
Computer requirements
Components
Minimum*
Notes:
* Minimum requirements are sufficient to run two to three GUI System Views, unless
otherwise noted. Recommended requirements are intended to be used as a general guideline
to optimize WaveStar® CIT performance. As the CIT is used with multiple NE connections
and multiple NE types, the processor type and speed and the memory size will all factor into
CIT performance.
Recommended
Processor
Pentium 266 MHz
Pentium IV 1 GHz
RAM (1 system view)
256 MB
512 MB
RAM (up to 5 system
views)
512 MB
1 GB
Virtual Memory
139 MB
267 MB
Available Hard Disk Space†
† Available hard disk space required to install and store the CIT and Generic Software and on-
line help files is approximately 750 MB. During installation, an additional 100 MB is
required. To store a copy of an NE generic, another 125 MB is needed for each generic
750 MB
850 MB (for all graphical
packages)
Video
800X600 256 Colors
(8 Bit)
1024X768 16 Million
Colors (24 Bit)
Network Interface
10/100 baseT Network Card
CD ROM Drive
Required
Operating System
Microsoft Windows® 7
Microsoft Windows® XP
Internet Browser
Internet Explorer
5.0/5.5/6.0/7.0
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical and power installation
Table I-2
Installation checklist
Section and chapter
Procedure
Required
Completed
Yes
No
Part I: “Physical and power installation”
Chapter 2, “Physical
installation”
Inspection (p. 2-5)
Yes
Alcatel-Lucent 1665 DMXtend center divider
(p. 2-5)
See Note 1
Alcatel-Lucent 1665 DMXtend shelf
installation (p. 2-8)
Yes
Power cable installation (p. 2-13)
Yes
Chapter 3, “Cable and fiber
installation”
Inspection (p. 3-5)
Yes
DS1/E1 cable installation (p. 3-6)
See Note 1
DS3/EC-1 cable installation (p. 3-13)
See Note 1
DS1 and DS3 hybrid cable installation (p. 3-30)
See Note 1
10/100BASE-T Ethernet cable installation (p.
3-36)
See Note 1
IAO LAN and TCP/IP cable installation (p. 3-
41)
See Note 1
Modem cable installation (p. 3-44)
See Note 1
Sync cable installation (p. 3-46)
See Note 1
Office alarm cable installation (p. 3-50)
See Note 1
Miscellaneous (environmental) discrete
telemetry cable installation (p. 3-54)
See Note 1
OC-3/OC-12/OC-48/OC-192 main optical fiber
cable installation (p. 3-58)
See Note 1
OC-3/OC-12/OC-48 low-speed optical fiber
cable installation (p. 3-61)
See Note 1
100/1000BASE-X optical fiber cable
installation (p. 3-62)
See Note 1
CIT (RS-232) cable installation (p. 3-64)
See Note 1
Final operations (p. 3-66)
Yes
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
I-7
............................................................................................................................................................................................................................................................
Physical and power installation
Chapter 4, “Circuit pack
installation”
Powering (p. 4-2)
Yes
Initial circuit pack installation (p. 4-9)
LNW2 (SYSCTL) installation (p. 4-10)
Yes
OC-3/OC-12/OC-48/OC-192 main OLIU
installation (p. 4-10)
Yes
LNW39/LNW391 (DS1/DS3/16/3), LNW111
(3DS3) and LNW112 (16DS1) installation
(optional) (p. 4-17)
See Note 1
LNW7 (28DS1PM) and LNW8/LNW801
(56DS1E1) installation (optional) (p. 4-12)
See Note 1
LNW16 (12DS3/EC1) and LNW19B
(48DS3/EC1) installation (optional) (p. 4-13)
See Note 1
LNW18 (12TMUX) and LNW20
(48TMUXDS3EC1) installation (optional) (p.
4-14)
See Note 1
LNW63 (GBE PL) 4 port or LNW64 (GBE PL)
8-port installation (optional) (p. 4-20)
See Note 1
LNW37 (OC-3 4 port PTM OLIU), LNW45
(OC-3 8 port PTM OLIU), or LNW603 (OC-
192 PTM OLIU) low-speed installation (p. 4-
16)
See Note 1
LNW49 (OC-12 4 port PTM OLIU) low-speed
installation (optional) (p. 4-18)
See Note 1
LNW62 (4 OC-48 PTM OLIU) or LNW55
(OC-3/OC-12/OC-48 12/4 port OLIU) low
speed installation (optional) (p. 4-19)
See Note 1
LNW63 (GBE PL) 4 port or LNW64 (GBE PL)
8-port installation (optional) (p. 4-20)
See Note 1
LNW73/73C (4-Fiber channel
FICON/ESCON) installation (optional) (p. 4-
21)
See Note 1
Section and chapter
Procedure
Required
Completed
Yes
No
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical and power installation
LNW74 (10/100T/F), LNW87 (FE/GBE PL),
or LNW910 (FE/GBE/10GBE) installation
(optional) (p. 4-22)
See Note 1
LNW170 (100/1G FXS) (p. 4-23)
See Note 1
LNW402 OC48 1310 nm, 1550 nm, or DWDM
PTM Optics (p. 4-24)
See Note 1
LNW63 (GBE PL) 4 port or LNW64 (GBE PL)
8-port installation (optional) (p. 4-20)
See Note 1
LNW785 OMD5/8 8-channel low-loss DWDM
optical mux/demux (p. 4-26)
See Note 1
LNW43, LNW96 (apparatus blank) installation
(optional) (p. 4-28)
See Note 1
LNW42, LNW95 apparatus blank installation
(optional) (p. 4-28)
See Note 1
Notes:
1.
Only required if equipped.
Section and chapter
Procedure
Required
Completed
Yes
No
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
2
Physical installation
Overview
Purpose
This section provides equipment installation instructions for the Alcatel-Lucent 1665 Data
Multiplexer Extend (Alcatel-Lucent 1665 DMXtend) shelf using the horizontal bay mount
configuration. The Alcatel-Lucent 1665 DMXtend shelves with the removable center
divider can support either half width or full width cards in the Main function slots.
Contents
This chapter provides information on the following topics:
Planning
Description
This section provides information about the following:
•
Tools, test equipment and accessories
•
Mounting options
•
Cabling checklist
Planning
2-1
Inspection
2-5
Alcatel-Lucent 1665 DMXtend center divider
2-5
Alcatel-Lucent 1665 DMXtend shelf installation
2-8
Power cable installation
2-13
Final operations
2-17
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Tools, test equipment and accessories
Listed below are the tools, test equipment and accessories necessary to perform the
procedures in this section.
Mounting options
The Horizontal Bay Mount mounting brackets on the Alcatel-Lucent 1665 DMXtend are
designed to allow for mounting in the following:
•
Standard 23-inch wide network bay frames
The recommended network bay frames are the ED-8C500-50 and the ED-8C501-50
(rear access only).
Quantity
Description
Comments
1
19" Mounting Brackets
849011804
The 19" mounting brackets (849011804) must be
ordered separately and are required to install the
Alcatel-Lucent 1665 DMXtend in a 19" bayframe.
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit
breakers to the OFF position.
1
ESD Wrist Strap R-4987C
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
1
Multimeter (Optional)
ITE-6379
The voltmeter must be capable of measuring DC
voltage in the 40 to 60 volt range. The use of the
voltmeter is optional since the shelf will alarm or
shut down if the proper voltage is not supplied.
1
Torque Wrench ITE-5952
A torque wrench (50-250 IN-LBS) is used when
tightening the Alcatel-Lucent 1665 DMXtend shelf
to the frame. It is also used when reattaching the
mounting brackets to the Alcatel-Lucent 1665
DMXtend shelf.
1
Metric & Inch Series Tool
Set
R - 6001
Because some of our Optical Networking Products
(also know as Transport) may have some metric
fasteners, please ensure that the proper metric tools
are available.
1
Ohmmeter ITE-6379
An ohmmeter is required to verify that the Alcatel-
Lucent 1665 DMXtend is properly grounded.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-3
............................................................................................................................................................................................................................................................
Physical installation
•
Mounted in 23-inch seismic network bay frame
The ED-8C800-50 and ED-8C801-50 seismic network bay frames are designed for use
in all earthquake zones, and in general, do not require top support at the 7-foot level.
These frames meet Pacific Bell Equipment Framework Standard PBS-000-102PT.
•
19-inch bay frames
•
23-inch wide EIA-Type bay frames
Rear cover assembly
This section describes the optional rear cover assembly kits for both Alcatel-Lucent 1665
DMXtend shelves, (Bay Mount Kit number 849001060) or Alcatel-Lucent 1665
DMXtend shelves (Shelf mount Kit number 849001367). Both kit assemblies will fit
either the 19" or 23" bracket assemblies. Figure 2-1 shows the shelf mount Kit assembly.
Note:
The shelves (Shelf mount Kit number 849001367) have four pre-drilled holes
in the shelf assembly backplane. If the shelf assembly backplane have the four non-
drilled holes, then the bay mount kit (Bay Mount Kit number 849001060) must be
used.
Shelf mount rear cover
Figure 2-1
Shelf mount rear cover kit 849001367
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Bay mount rear cover
Figure 2-2
Bay mount rear cover kit 849001060
Note:
The rear bay cover requires the front mounting configuration of the Alcatel-
Lucent 1665 DMXtend shelf. This is mounting the shelf on the front of the bay with 5
inches of the shelf protruding from the front of the bay.
Cabling checklist
This section briefly describes cabling information, including the number of particular
cables required. For information regarding available cable lengths and ordering comcodes,
see the tables in this chapter.
Table 2-1, “Cable requirements and options” (p. 2-4) lists available cables along with the
required number (if any).
Table 2-1
Cable requirements and options
1. One -48VA and -48VB main power feeder is required per shelf. The shelf requires the
use of a right angle power connector on each feed.
Cable assembly description
Required
See note
Power
Yes
1
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-5
............................................................................................................................................................................................................................................................
Physical installation
Inspection
Description
Perform the following procedure before installing the Alcatel-Lucent 1665 DMXtend
shelf.
Steps
........................................................................................................................................................................................................................
1
Inspect the shelf for visible damage including bent or touching backplane pins.
Note:
If any backplane pins are damaged, see Appendix D, “Backplane pin
replacement” for instructions on repairing the damaged pin(s).
........................................................................................................................................................................................................................
2
Each Alcatel-Lucent 1665 DMXtend shelf comes with an installation kit. The bag
containing the kit is attached inside the Alcatel-Lucent 1665 DMXtend shelf. The kit
contains the following items:
Verify that the kit is available and contains the items listed above.
........................................................................................................................................................................................................................
3
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
Alcatel-Lucent 1665 DMXtend center divider
Description
The Alcatel-Lucent 1665 DMXtend shelves, comcode 849031372, come shipped with
center dividers which can support half-width cards. The center dividers are removed for
full-width cards. This section describes the procedure to remove the center dividers on a
Alcatel-Lucent 1665 DMXtend shelf if supporting full width cards.
Quantity
Description
6
Thread Cutting Screws
1
ESD Jack stud
1
Caution Label
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
New installation
The procedure below describes how to remove the center dividers for new installations.
Steps
The figure below shows the new Alcatel-Lucent 1665 DMXtend shelf with the center
dividers inserted.
Note:
The center dividers come equipped with a spring clip CC849027222 not
shown in Figure 2-3, “Center divider” (p. 2-6) that latches the dividers together.
Remove this spring clip by inserting a finger into the hole and pulling gently away
from the shelf. Keep this spring clip available if there is ever a need to reinstall the
center divider for the use of half-width cards in the shelf.
Figure 2-3
Center divider
........................................................................................................................................................................................................................
1
To remove the top center divider, depress the spring clip latch located on top of the divider
and slide the divider out.
........................................................................................................................................................................................................................
2
Remove the bottom center divider by depressing the bottom spring clip and sliding the
divider out.
........................................................................................................................................................
E N D O F S T E P S
Existing installation
This procedure is used to remove the center dividers if circuit packs are installed above or
below the dividers and the spring clip is not accessable.
Center
Divider
Spring
clip
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-7
............................................................................................................................................................................................................................................................
Physical installation
Steps
The figure below shows the Alcatel-Lucent 1665 DMXtend shelf with both center dividers
inserted and a working circuit pack installed above the top divider.
Figure 2-4
Center divider with circuit packs installed.
........................................................................................................................................................................................................................
1
Using a small flat screwdriver, separate the padding as shown in Figure 2-4, “Center
divider with circuit packs installed.” (p. 2-7).
........................................................................................................................................................................................................................
2
Insert the screwdriver approximately two thirds of the way up from the bottom of the top
divider and depress the latch.
........................................................................................................................................................................................................................
3
Gently slide out the center divider.
........................................................................................................................................................................................................................
4
Repeat for the bottom center divider if necessary. The latch on the bottom divider moves
bottom to top.
........................................................................................................................................................
E N D O F S T E P S
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Alcatel-Lucent 1665 DMXtend shelf installation
Description
As an example of the Alcatel-Lucent 1665 DMXtend shelf installation, the following steps
describe mounting the shelf from the front of a 23-inch bay frame. Mounting from the rear
of a 23-inch bay frame or from the front/rear of a 19-inch bay frame is similar with the
exception of the position of the side brackets.
Positioning of the side brackets is also specified.
Note:
This section requires previous bay frame installation and grounding.
Note:
If the Alcatel-Lucent 1665 DMXtend shelf is to be used in an outside cabinet
with no exchange of outside air, the air filter must be removed.
Steps
........................................................................................................................................................................................................................
1
Position the Alcatel-Lucent 1665 DMXtend shelf on a stable work surface.
........................................................................................................................................................................................................................
2
Open the front cover, remove the installation kit bag, and remove the caution label from
the bag.
........................................................................................................................................................................................................................
3
Apply the label to the shelf in a position where it will be visible when the shelf is mounted
in the bayframe.
Note:
The recommended position is on the left side of the inside of the front cover,
but the customer may position it to fit their local practices as long as it is visible when
accessing the front of the Alcatel-Lucent 1665 DMXtend shelf.
........................................................................................................................................................................................................................
4
Close and latch the front cover.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-9
............................................................................................................................................................................................................................................................
Physical installation
........................................................................................................................................................................................................................
5
Determine the mounting configuration for the Alcatel-Lucent 1665 DMXtend shelf:
•
Type of bay frame (23-inch or 19-inch wide)
•
Mounting position (front or rear)
•
Position in bay (bottom to top).
Note:
The Alcatel-Lucent 1665 DMXtend shelf is shipped with the mounting
brackets positioned for mounting to the front of a 23-inch wide network bay frame
with a 5 in. setback.
The Alcatel-Lucent 1665 DMXtend shelf mounting brackets may have to be repositioned
and remounted, depending on the frame type and mounting position (front or rear).
........................................................................................................................................................................................................................
6
If necessary, reposition the shelf mounting brackets accordingly.
For 23-inch frame, front or rear mounting, see Figure 2-5, “Alcatel-Lucent 1665
DMXtend mounting bracket positions - 23-Inch/19-Inch frame” (p. 2-10).
Note:
The 19" mounting brackets (C849011804) must be ordered separately and are
required to install the Alcatel-Lucent 1665 DMXtend in a 19" bayframe.
For 19-inch frame, front or rear mounting, see Figure 2-5, “Alcatel-Lucent 1665
DMXtend mounting bracket positions - 23-Inch/19-Inch frame” (p. 2-10).
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Figure 2-5
Alcatel-Lucent 1665 DMXtend mounting bracket positions - 23-Inch/19-
Inch frame
........................................................................................................................................................................................................................
7
Determine the position that the Alcatel-Lucent 1665 DMXtend shelf will be mounted.
Note:
Start at the bottom of the bay and add shelves from bottom to top.
6.0 in.
5.0 in.
8.0 in.
Front Mount Left Side
Front Mount Left Side
Rear Mount Left Side
Front
Front
Front
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-11
............................................................................................................................................................................................................................................................
Physical installation
Fiber duct
This section will describe how to install an optional fiber duct.
Note:
If a fiber duct is being used to diversify fiber, a 1-inch space is required to
accommodate the duct below the existing Alcatel-Lucent 1665 DMXtend. Use the
Assembly Fiber Duct kit drawing 848949152 to attach the duct to the Alcatel-Lucent
1665 DMXtend. See Figure 2-6, “Fiber duct mounting” (p. 2-11).
Figure 2-6
Fiber duct mounting
........................................................................................................................................................................................................................
8
Position the Alcatel-Lucent 1665 DMXtend shelf in the frame and secure the shelf to the
frame using the thread-forming screws included with the shelf (3 screws per side). Tighten
the screws to 21 in.-lb. (minimum)/30 in.-lb. (maximum).
Note:
There is a jumper on the fan controller board, at the corner closest to the top-
rear of the chassis as installed. It is labeled "FILT BLK" and the two positions are
"ENABLE" and "DISABLE." The fan ships with the jumper in the disable position
which prevents the filter alarm from working. To enable the filter alarm, move the
jumper to the "ENABLE" position. This is the only jumper on the board. The OSP
cabinet must be engineered so that the Alcatel-Lucent 1665 DMXtend does not
impede air flow to other equipment in the cabinet. The OSP cabinet must be
engineered to provide a two inch open space on the left and right sides of the Alcatel-
Lucent 1665 DMXtend for air flow. Mounting frame and flanges may intrude on this
space.
Note:
Be sure to mount the shelf using the thread-forming screws provided with the
shelf to ensure a solid ground connection from the bay to the shelf.
Note:
For bays that use power coat paint e.g., most 19" bays, studies on that type of
paint indicate that the material is not always removed cleanly using the thread forming
screws and can create a poor ground, thus we recommend a secondary ground be used.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
The secondary ground would consist of a 12 AWG wire from the UL (Green M5
Screw) safety ground on the lower left side of the rear of the shelf to the bayframe
(where the bayframe has been scraped clean of paint and treated with no-ox) or
directly to the office ground. See Figure 2-7, “Safety ground screw.” (p. 2-12).
Figure 2-7
Safety ground screw.
........................................................................................................................................................................................................................
9
Mount the ESD Jack Stud on the rear of the bayframe where it will be accessible when
accessing the rear of the shelf.
........................................................................................................................................................................................................................
10
If fiber spools are to be used, attach the spools to the Alcatel-Lucent 1665 DMXtend using
the Fiber Spool Bracket Kit drawing 848949152. Attach the bracket to the shelf first and
then the top fiber spool to the bracket. The lower fiber spool will need to overlap the top
spool to snap into place. Run the excess fiber per office practices around the spools to
minimize the bend radius. See Figure 2-8, “Fiber spools” (p. 2-13).
........................................................................................................................................................................................................................
11
If Alcatel-Lucent fiber ducts are used, see Figure 2-8, “Fiber spools” (p. 2-13). All high-
speed fibers are to be run in the duct closest to the shelf for both left and right ducts. The
next two ducts away from the shelf are for low-speed fibers.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-13
............................................................................................................................................................................................................................................................
Physical installation
Figure 2-8
Fiber spools
........................................................................................................................................................................................................................
12
Verify with an ohmmeter that the Alcatel-Lucent 1665 DMXtend shelf is grounded to the
bay frame. Measure between the Alcatel-Lucent 1665 DMXtend shelf mounting bracket
and the office ground lug on the bay frame.
Requirement: The ohmmeter reads less than 1 ohm.
........................................................................................................................................................................................................................
13
Verify with an ohmmeter that the ESD Jack Stud mounted at the rear of the shelf is
grounded to the bay frame. Measure between the ESD Jack Stud and the office ground lug
on the bay frame.
Requirement: The ohmmeter reads less than 1 ohm.
........................................................................................................................................................................................................................
14
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
Power cable installation
Description
This section provides instructions on installing the power cable and cable bracket for the
Alcatel-Lucent 1665 DMXtend shelf.
Two feeders (A and B) are required from the battery distribution fuse board (BDFB) or
battery distribution circuit breaker bay (BDCBB) to the Alcatel-Lucent 1665 DMXtend
bay.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Table 2-2, “Power cable assemblies” (p. 2-16) and Table 2-3, “Power connections”
(p. 2-16) lists the available power cable assemblies and power connections, respectively.
Steps
........................................................................................................................................................................................................................
1
Connect the A and B power cables to the A and B power connector housings on the back
of the Alcatel-Lucent 1665 DMXtend Shelf. See Figure 2-9, “Power connection”
(p. 2-14).
Figure 2-9
Power connection
........................................................................................................................................................................................................................
2
Route the power cable out of the bay and toward the BDCBB or BDFB, stacking the cable
in the bay.
Note:
The Alcatel-Lucent 1665 DMXtend is powered by -48 V DC.
........................................................................................................................................................................................................................
3
Splice feeders from the BDCBB or BDFB to the Alcatel-Lucent 1665 DMXtend power
cable. See Table 2-3, “Power connections” (p. 2-16). and should be labeled as follows;
CAUTION
Verify that the BDCBB breakers are off or that the BDFB fuses are not installed.
CAUTION
Ensure that the four parts of the terminal inside the connector attached to the
power cable are properly aligned before inserting the connector into the power
connector housing. Failure to do so may result in damage to the connector.
CAUTION
Verify that the BDCBB breakers are off or that the BDFB fuses are not installed.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-15
............................................................................................................................................................................................................................................................
Physical installation
Note:
Four wires are spliced to the power cables.
1. BAT A
2. BAT A RTN
3. BAT B
4. BAT B RTN
Note:
Each feeder at the BDCBB or BDFB should be fused for 25 amperes for bay
arrangements and 15 amperes for a single shelf.
........................................................................................................................................................................................................................
4
Leave the BDCBB breakers off or BDFB fuses out until you are ready to perform the
procedures in Chapter 4, “Circuit pack installation” of this manual.
........................................................................................................................................................................................................................
5
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Table 2-2
Power cable assemblies
Table 2-3
Power connections
Description
Cable
assembly #
Cable length
(feet)
Jacket
color
Alcatel-Lucent 1665
DMXtend backplane
connections
Power Cable
Kits with Right
Angle
Connectors and
Two 6 Gauge
cables
848929493
85
One Red
and One
Blue
Connectors on rear of the
shelf (BAT A and BAT B)
848929501
100
Power Cable
Kits with Right
Angle
Connectors and
Two 8 Gauge
cables
848929519
55
848929527
100
Power Cable
Kits with Right
Angle
Connectors and
10 Gauge
cables
848929535
12
848929543
50
848929550
75
848929568
100
848841839
12
Has far end connectors for
a power distribution panel
14 AWG
848999496
15
Alcatel-
Lucent 1665
DMXtend
bkpl conn.
Shelf
power
connectors
Pin #
Color
Designation
Name
Cable
Wire
P10
BAT A
1
Red
R
-48VA
BAT A
2
W
-48RTNA
BAT A RTN
P11
BAT B
1
Blue
R
-48VB
BAT B
2
W
-48RTNB
BAT B RTN
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
2-17
............................................................................................................................................................................................................................................................
Physical installation
Final operations
Description
Final check on equipment installation.
Steps
........................................................................................................................................................................................................................
1
Verify that all the power cables are properly dressed/connected.
........................................................................................................................................................................................................................
2
Verify that all power cables are properly labeled.
........................................................................................................................................................................................................................
3
Replace rear cover on shelf if ordered.
........................................................................................................................................................................................................................
4
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
............................................................................................................................................................................................................................................................
Physical installation
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
3
Cable and fiber
installation
Overview
Purpose
This section provides cabling instructions for the Alcatel-Lucent 1665 Data Multiplexer
Extend (Alcatel-Lucent 1665 DMXtend) shelf using the horizontal bay mount
configuration. The Alcatel-Lucent 1665 DMXtend shelves with the removable center
divider can support either half width or full width cards in the Main function slots.
Note:
Ensure only ANGLED LC connectors appear at IN ports of optical circuit
packs. The “ANGLED” is referring to the rotating boot on the connector and not the
connector. APC or Angled Polished Connectors are not supported.
Contents
This chapter provides information on the following topics
Planning
3-2
Connector references
3-4
Inspection
3-5
DS1/E1 cable installation
3-6
DS3/EC-1 cable installation
3-13
DS1 and DS3 hybrid cable installation
3-30
10/100BASE-T Ethernet cable installation
3-36
IAO LAN and TCP/IP cable installation
3-41
Modem cable installation
3-44
Sync cable installation
3-46
Office alarm cable installation
3-50
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Planning
Description
This section provides information about the following:
•
Tools, test equipment and accessories
•
Mounting options
•
Cabling checklist
Tools, test equipment and accessories
Listed below are the tools, test equipment and accessories necessary to perform the
procedures in this section.
Miscellaneous (environmental) discrete telemetry cable installation
3-54
OC-3/OC-12/OC-48/OC-192 main optical fiber cable installation
3-58
OC-3/OC-12/OC-48 low-speed optical fiber cable installation
3-61
100/1000BASE-X optical fiber cable installation
3-62
CIT (RS-232) cable installation
3-64
Final operations
3-66
Quantity
Description
Comments
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting screws,
repositioning the mounting brackets, installing the
interfacing cables, and for setting the circuit
breakers to the OFF position.
1
Thomas & Betts1
R-5648B Crimping Tool
1.
The crimping tool, wire stripper and soldering
iron are only required if installing DS3/EC-1
cables. The replacement cassette is for the wire
stripper tool.
2
Paladin2 Coaxial Wire
Stripper R-5648B D5
Replacement Paladin2
Cassette R-5648B D5
1
Wire-Wrap Gun R-4496A
The wire-wrap gun is required for terminating
DS1/E1 cable and must be able to accommodate 24
gauge wire.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-3
........................................................................................................................................................................
Cable and fiber installation
Cabling checklist
This section briefly describes cabling information, including the number of particular
cables required. For information regarding available cable lengths and ordering comcodes,
see the tables in this chapter.
Table 3-1, “Cable requirements and options” (p. 3-3) lists available cables along with the
required number (if any).
Table 3-1
Cable requirements and options
1
ESD Wrist Strap R-4987C
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
1
Multimeter (Optional)
ITE-6379
The voltmeter must be capable of measuring DC
voltage in the 40 to 60 volt range. The use of the
voltmeter is optional since the shelf will alarm or
shut down if the proper voltage is not supplied.
Notes:
1 Registered trademark of Thomas & Betts Corporation
2 Registered trademark of Paladin Corporation.
Quantity
Description
Comments
Cable assembly description
Required
See note
CIT
Yes
1
DS1/E1
Optional
2
DS3/EC-1
Optional
3, 4
DS1/DS3 Hybrid
Optional
5
Office Alarm
Optional
6
Office Alarm Mult
Optional
6
Miscellaneous Discrete
Optional
LAN 10BASE-T (Crossover)
Optional
7
LAN 10BASE-T (Straight Through)
Optional
7
Sync Timing
Optional
Modem
Optional
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
1. One CIT Cable Assembly is required for PC interface with the Alcatel-Lucent 1665
DMXtend (not included with equipment).
2. Two DS1/E1 Cable Assembly are required for each D or G function unit group that
will support additional DS1/E1 traffic using the LNW8/801. Each DS1/E1 Cable
Assembly consists of two separate cable assemblies, both containing 28 pairs of 24
gauge cable. One cable is for input and the other cable is for output.
3. One DS3/EC-1 Cable Assembly is required for each D or G function unit group that
will support 12 DS3’s of traffic. Each DS3/EC-1 Cable Assembly consists of two
separate cable assemblies, both containing 735A cables. One cable consists of 12
inputs and the other cable consists of 12 outputs.
4. Two DS3/EC-1 Cable Assembly are required for each D or G function unit group that
will support additional DS3/EC-1 traffic using the LNW19B or LNW20. Each
DS3/EC-1 Cable Assembly consists of two separate cable assemblies, both containing
735A cables. One cable consists of 24 inputs and the other cable consists of 24
outputs.
5. One DS1/DS3 Hybrid Cable Assembly is required for A/B function unit Group to
support use of the LNW39 (16DS1/3DS3), LNW84 (16DS1/3DS3), LNW111 (3DS3),
LNW112 (16DS1), and LNW391 (16DS1/3DS3) Hybrid. Each DS1/DS3 Hybrid
Cable Assembly consists of two separate cable assemblies, both containing 28 pairs of
24 gauge cable a Coaxial 735A cable. One cable is for input and the other cable is for
output.
6. When cabling the Alcatel-Lucent 1665 DMXtend for office alarm applications, one
Office Alarm Cable Assembly is required for the bottom Alcatel-Lucent 1665
DMXtend shelf in a bay frame. One Office Alarm Mult Cable Assembly is required
for each additional Alcatel-Lucent 1665 DMXtend shelf in the bay frame. For
example, if four Alcatel-Lucent 1665 DMXtend shelves are located in a single 7-foot
bay frame, one Office Alarm Cable Assembly and three Office Alarm Mult Cable
Assemblies are required.
7. These cables are used for IAO LAN (OSI/TCP-IP)/Front LAN (OSI/TCP-IP)
connection (J16 and Front LAN port). LAN 10BASE-T cross over cable should be
used if the shelf is directly connected to a PC and LAN 10BASE-T straight through
cable should be used if shelf is connected to a hub.
Connector references
Description
Figure 3-1 provides the pinouts of some of the connectors used to interface with the
Alcatel-Lucent 1665 DMXtend.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-5
........................................................................................................................................................................
Cable and fiber installation
Figure 3-1
Connector types and pinouts
Inspection
Description
Perform the following procedure before installing the Alcatel-Lucent 1665 DMXtend
cables.
Steps
................................................................................................................................................
1
Inspect the shelf for visible damage including bent or touching backplane pins.
DB-9 male-type connector
DB-15 male-type connector
DB-25 male-type connector
DB-62 male-type connector
1
5
6
9
1
8
9
15
1
13
14
25
1
21
43
62
22
42
DB-9 female-type connector
DB-15 female-type connector
DB-25 female-type connector
DB-62 female-type connector
1
5
6
9
8
1
15
9
13
1
25
14
21
1
62
43
42
22
RJ-45 type connector
1
8
1
8
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Note:
If any backplane pins are damaged, see Appendix D, “Backplane pin
replacement” for instructions on repairing the damaged pin(s).
................................................................................................................................................
2
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
DS1/E1 cable installation
Description
This section describes how to connect the DS1/E1 transmission cables for function group
D or G, to the shelf, route the cables out of the bay and connect the cables to the DSX.
Perform this procedure if DS1/E1 cables are required.
Note:
When cabling the Alcatel-Lucent 1665 DMXtend to a DSX, the DSX
becomes an extension of the Alcatel-Lucent 1665 DMXtend backplane connections.
Thus the IN on the Alcatel-Lucent 1665 DMXtend backplane connects to the IN of the
DSX and the OUT of the Alcatel-Lucent 1665 DMXtend backplane connects to the
OUT of the DSX respectively.
The cables have connectors at the Alcatel-Lucent 1665 DMXtend shelf end and must be
wire-wrapped at the DSX end. A total of two function groups fully cabled will have 112
DS1/E1 drop capacity.
Note:
The 112 DS1 drops do not include the 16 port DS1 drop available when using
the LNW39/LNW391 DS1/DS3/16/3 combo card in slot A/B or the LNW84.
Instructions for cabling slot A/B are provided in “DS1 and DS3 hybrid cable
installation” (p. 3-30).
Note:
The connectorized cable end is grounded to the Alcatel-Lucent 1665
DMXtend frame ground through the backplane. Alcatel-Lucent recommends that the
shield at both ends of the DS1/E1 cable be grounded. Ground at the DSX end per
office requirements.
Steps
................................................................................................................................................
1
See the engineering job specification. Obtain the DS1/E1 cables per Table 3-2, “DS1/E1
cable assemblies” (p. 3-9) and note the function group where each cable will be used.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-7
........................................................................................................................................................................
Cable and fiber installation
Label the cables, indicating bay, shelf, function group (D or G) and direction (IN or OUT
of the bay) at each end.
................................................................................................................................................
2
Connect the function group cables at the Alcatel-Lucent 1665 DMXtend end, carefully
matching the correct connector with the appropriate backplane connectors as shown in
Figure 3-2, “DS1/E1 cable connectors” (p. 3-7).
Note:
DS1/E1 cable retaining screws must be tightened to a maximum of 6.5 in-lb.
Do not overtighten.
Note:
The first 28 DS1/E1s of a Function Group must be connected to the right side
connectors (J1D, J3D, J7G, and J9G). An additional capacity of 28 DS1/E1s, 29-56,
are used when the LNW8 circuit pack is used. The second 28 DS1/E1s of a Function
Group are connected to the backplane (J2D, J4D, J8G, and J10G).
Note:
The DS1/E1 cables that connect to the right side connectors (J1D, J3D, J7G,
and J9G) are different from the cables that connect to the connectors in the center of
the backplane (J2D, J4D, J8G, and J10G). See Table 3-2, “DS1/E1 cable assemblies”
(p. 3-9) for more information.
Figure 3-2
DS1/E1 cable connectors
................................................................................................................................................
3
Route the cables along the backplane and out of the bay to the DSX.
Note:
Cables from J1D, J3D, J7G, and J9G route to the right of the shelf (when
facing the rear of the shelf) and up the bay frame. See Figure 3-3, “DS1/E1 cable
routing to the right” (p. 3-8). Cables from J2D, J4D, J8G, and J10G route to the left of
the shelf (when facing the rear of the shelf) and up the bay frame. See Figure 3-4,
“DS1/E1 cable routing to the left” (p. 3-8).
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Note:
When dressing the cables from the connectors in the center of the shelf be sure
to allow for access to connectors to the left or right of the center connectors depending
on whether cable dresses to the right or the left. See Figure 3-4, “DS1/E1 cable routing
to the left” (p. 3-8).
Figure 3-3
DS1/E1 cable routing to the right
Figure 3-4
DS1/E1 cable routing to the left
................................................................................................................................................
4
Route the cables along the cable rack and into the terminating bay.
................................................................................................................................................
5
Remove slack and cut the DS1/E1 cables to the desired length at the DSX.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-9
........................................................................................................................................................................
Cable and fiber installation
................................................................................................................................................
6
Referring to Table 3-3, “DS1 transmission connections” (p. 3-11), carefully observe color
codes and wire-wrap the cables at the DSX.
................................................................................................................................................
7
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S
Table 3-2
DS1/E1 cable assemblies
Cable length
(feet)
Cable
assembly #
Description
Alcatel-Lucent 1665
DMXtend backplane
connections
10
848954988
20
848955001
30
848923074
Function Group G
DS1/E1 In (CA1) and
DS1/E1 Out (CA2) Cable
Function Group D
DS1/E1 In (CA1) and
DS1/E1 Out (CA2) Cable
These cables route to the
left (as viewed from the
rear of the shelf) and
should be used with
connectors J2D (IN),
J4D (OUT) and J8G
(IN), J10G (OUT)
50
848548327
75
848923082
100
848548335
125
848923090
150
848548343
175
848923108
200
848923116
250
848548350
350
848790762
450
848548368
550
848790770
655
848790788
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
10
848954962
Function Group G
DS1/E1 In (CA1) and
DS1/E1 Out (CA2) Cable
Function Group D
DS1/E1 In (CA1) and
DS1/E1 Out (CA2) Cable
These cables route to the
right (as viewed from
the rear of the shelf) and
should be used with
connectors J1D (IN),
J3D (OUT) and J7G
(IN), J9G (OUT)
20
848954970
30
848934964
50
848912473
75
848934972
100
848912564
125
848934980
150
848912648
175
848934998
200
848935003
250
848912671
350
848912978
450
848912986
550
848913000
655
848935011
Notes:
1.
Each Cable Assembly # is a kit that contains 2 cables. For Input connections use cable
CA1 (DS1/E1 IN) and for Output connections use cable CA2 (DS1/E1 OUT).
2.
Each Cable Assembly # that routes to the right (when facing the rear of the shelf), listed
includes all the DS1/E1 cables for one function group using the 28DS1 card.
3.
In addition to each Cable Assembly # that route to the right (when facing the rear of the
shelf), one Cable Assembly # of cables that route to the left (when facing the rear of the
shelf), must be ordered for the additional capacity of the 56DS1/E1 card.
4.
Alcatel-Lucent 1665 DMXtend connectors J1D through J4D and J7G through J10G
can be used for either DS1/E1 or DS3/EC-1 cabling.
5.
Cables are terminated in J1D through J4D and J7G through J10G connectors at the
Alcatel-Lucent 1665 DMXtend end and unterminated at the other end for wire-wrap
installation.
6.
The cable connectors are 62 pins D-Sub male-type connectors and fit into J1D through
J4D and J7G through J10G.
7.
The DS1/E1 cables are 24 Gauge.
Cable length
(feet)
Cable
assembly #
Description
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-11
........................................................................................................................................................................
Cable and fiber installation
Table 3-3
DS1 transmission connections
DSX-1 connections
Alcatel-Lucent 1665 DMXtend
backplane connections
G
r
o
u
p
ChanD
S1
T/R
term
T/R
color
62-Pin
conn.
pin#
T/R
Function
group D
conn.
Function
group G
conn.
In
Out
In
Out
1
1 (1)
2 (2)
3 (3)
4 (4)
B8/B7
B6/B5
B4/B3
B2/B1
W/BL¹
W/O¹
W/G¹
W/BR
19/40
18/39
60/59
17/38
J1D
D
In
J3D
D
Out
J7G
G
In
J9G
G
Out
2
1 (5)
2 (6)
3 (7)
4 (8)
B8/B7
B6/B5
B4/B3
B2/B1
W/S
R/BL
R/O
R/G
58/57
16/37
15/36
14/35
3
1 (9)
2 (10)
3 (11)
4 (12)
B8/B7
B6/B5
B4/B3
B2/B1
R/BR
R/S
BK/BL
BK/O
56/55
13/34
54/53
12/33
4
1 (13)
2 (14)
3 (15)
4 (16)
B8/B7
B6/B5
B4/B3
B2/B1
BK/G
BK/BR
BK/S
Y/BL
11/32
10/31
52/51
9/30
5
1 (17)
2 (18)
3 (19)
4 (20)
B8/B7
B6/B5
B4/B3
B2/B1
Y/O
Y/G
Y/BR
Y/S
50/49
8/29
7/28
6/27
6
1 (21)
2 (22)
3 (23)
4 (24)
B8/B7
B6/B5
B4/B3
B2/B1
V/BL
V/O
V/G
V/BR
48/47
5/26
46/45
4/25
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
7
1 (25)
B8/B7
V/S
3/24
2 (26)
3 (27)
4 (28)
B6/B5
B4/B3
B2/B1
W/BL¹
W/O¹
W/G¹
2/23
44/43
1/22
1
1 (29)
2 (30)
3 (31)
4 (32)
B8/B7
B6/B5
B4/B3
B2/B1
W/BL1
W/O1
W/G1
W/BR
19/40
18/39
60/59
17/38
J2D
D
In
J4D
D
Out
J8G
G
In
J10G
G
Out
2
1 (33)
2 (34)
3 (35)
4 (36)
B8/B7
B6/B5
B4/B3
B2/B1
W/S
R/BL
R/O
R/G
58/57
16/37
15/36
14/35
3
1 (37)
2 (38)
3 (39)
4 (40)
B8/B7
B6/B5
B4/B3
B2/B1
R/BR
R/S
BK/BL
BK/O
56/55
13/34
54/53
12/33
4
1 (41)
2 (42)
3 (43)
4 (44)
B8/B7
B6/B5
B4/B3
B2/B1
BK/G
BK/BR
BK/S
Y/BL
11/32
10/31
52/51
9/30
5
1 (45)
2 (46)
3 (47)
4 (48)
B8/B7
B6/B5
B4/B3
B2/B1
Y/O
Y/G
Y/BR
Y/S
50/49
8/29
7/28
6/27
6
1 (49)
2 (50)
3 (51)
4 (52)
B8/B7
B6/B5
B4/B3
B2/B1
V/BL
V/O
V/G
V/BR
48/47
5/26
46/45
4/25
DSX-1 connections
Alcatel-Lucent 1665 DMXtend
backplane connections
G
r
o
u
p
ChanD
S1
T/R
term
T/R
color
62-Pin
conn.
pin#
T/R
Function
group D
conn.
Function
group G
conn.
In
Out
In
Out
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-13
........................................................................................................................................................................
Cable and fiber installation
DS3/EC-1 cable installation
Description
This section describes how to connect the DS3/EC-1 cables to the Alcatel-Lucent 1665
DMXtend shelf and route the cables out of the bay and to the DS3/EC-1 terminating
equipment.This procedure covers both the 12 cable and the 24 cable DS3/EC1 cables.
Perform this procedure if DS3/EC-1 cables are required.
Note:
When cabling the Alcatel-Lucent 1665 DMXtend to a DSX, the DSX
becomes an extension of the Alcatel-Lucent 1665 DMXtend backplane connections.
Therefore, the IN on the Alcatel-Lucent 1665 DMXtend backplane connects to the IN
of the DSX and the OUT of the Alcatel-Lucent 1665 DMXtend backplane connects to
the OUT of the DSX respectively
DS3/EC-1 cable options are listed in Table 3-4, “DS3/EC-1 cable assemblies” (p. 3-17).
DS3/EC-1 transmission connections are in Table 3-5, “Twenty-four cable DS3/EC-1
transmission connections” (p. 3-24) and Table 3-6, “Twelve cable DS3/EC-1 transmission
connections” (p. 3-28). Total of two function groups fully cabled will have 96 DS3 drop
capacity.
Note:
The 96 DS3 figure does not include the 3 DS3 drops available when using the
LNW39/LNW391 16/DS1/3/DS3 combo card in slot A/B. Instructions for cabling slot
A/B are provided in “DS1 and DS3 hybrid cable installation” (p. 3-30).
7
1 (53)
B8/B7
V/S
3/24
2 (54)
3 (55)
4 (56)
B6/B5
B4/B3
B2/B1
W/BL¹
W/O¹
W/G¹
2/23
44/43
1/22
Notes:
1.
Some wire colors are used twice. White binder cables are for Channel 1
through 25 or Channel 29 through 53 and blue binder cables are for Channels
26, 27 and 28 or Channels 54, 55 and 56 are shaded.
DSX-1 connections
Alcatel-Lucent 1665 DMXtend
backplane connections
G
r
o
u
p
ChanD
S1
T/R
term
T/R
color
62-Pin
conn.
pin#
T/R
Function
group D
conn.
Function
group G
conn.
In
Out
In
Out
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Steps
................................................................................................................................................
1
See the engineering job specification. Obtain the DS3/EC-1 cables per Table 3-4,
“DS3/EC-1 cable assemblies” (p. 3-17) and note the function group where each cable will
be used. Label the cables, indicating bay, shelf, function group (D or G) and direction (IN
or OUT of the bay) at each end.
Note:
The first 12/24 ports of a function unit must be cabled to the right side
connectors (J1D, J3D, J7G, and J9G), the additional DS3/EC-1 capacity ports (25 -
48) are cabled to the center connectors of the shelf (J2D, J4D, J8G, and J10G).
................................................................................................................................................
2
Connect the function group cables at the Alcatel-Lucent 1665 DMXtend end, carefully
matching the correct connector with the appropriate backplane connectors as shown in
Figure 3-5, “DS3/EC-1 cable connections” (p. 3-15).
Note:
DS3/EC-1 and TMUX cable retaining screws must be tightened to a
maximum of 6.5 in-lb. Do not overtighten.
Note:
The 12 conductor DS3/EC-1 cables that support the LNW16 12DS3/EC-1
pack connect only to the right side connectors (J1D, J3D, J7G, and J9G). The
connectors in the center of the backplane (J2D, J4D, J8G, and J10G) are not used with
the LNW16. See Table 3-4, “DS3/EC-1 cable assemblies” (p. 3-17) for more
information.
Note:
The first 12/24 DS3/EC-1s of a Function Group must be connected to the right
side connectors (J1D, J3D, J7G, and J9G). See Figure 3-6, “DS3/EC-1 cable routing to
the right” (p. 3-15). The additional capacity of 24 DS3/EC-1s of the Function Group
use the connectors located to the center of the backplane (J2D, J4D, J8G, and J10G).
Note:
The 24 conductor DS3/EC-1 cables that connect to the right side connectors
(J1D, J3D, J7G, and J9G) are different from the 24 cable DS3/EC-1 cables that
connect to the connectors in the center of the backplane (J2D, J4D, J8G, and J10G).
See Table 3-4, “DS3/EC-1 cable assemblies” (p. 3-17) for more information.
Function
group
Associated connector (DS3/EC-1)
G
G IN (J7G and J8G) G OUT (J9G and J10G)
D
D IN (J1D and J2D) D OUT (J3D and J4D)
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-15
........................................................................................................................................................................
Cable and fiber installation
Figure 3-5
DS3/EC-1 cable connections
................................................................................................................................................
3
Route the cables along the backplane and out of the bay to the DSX per Figure 3-6,
“DS3/EC-1 cable routing to the right” (p. 3-15).
Figure 3-6
DS3/EC-1 cable routing to the right
Notes: The 12-conductor DS3/EC-1 cable is showing that this cable could be either
the 12- or 24-conductor DS3/EC-1 cable.
Ports
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Figure 3-7
DS3/EC-1 cable routing to the left
Notes: The 12-conductor DS3/EC-1 cable is shown.
................................................................................................................................................
4
Route the cables along the cable rack and into the terminating bay (DSX or other
terminating transmission equipment).
................................................................................................................................................
5
Cut the cables to desired length and install the BNC connectors shipped with the cable
assemblies.
Note:
When installing BNC connectors, follow the manufacturer’s instruction
carefully to ensure a proper connection. Failure to do so may result in faulty DS3/EC-
1 signals as a result of improperly installed BNC connectors.
................................................................................................................................................
6
Connect the cables to their respective positions on the terminating equipment.See
Table 3-5, “Twenty-four cable DS3/EC-1 transmission connections” (p. 3-24) or
Table 3-6, “Twelve cable DS3/EC-1 transmission connections” (p. 3-28) for DS3/EC-1
connections.
Note:
The 12-port cable and the 24-port cable use different signal grounds based on
the circuit pack not the backplane. There is no issue interchanging these cables on the
backplane. The DS3/EC-1 Signals are common between both cables.
................................................................................................................................................
7
Check off the appropriate box in the Table I-2, Installation checklist.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-17
........................................................................................................................................................................
Cable and fiber installation
Table 3-4
DS3/EC-1 cable assemblies
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Function group D
and G
12 Cable DS3/
EC-1 In (CA1) and
12 Cable DS3/EC-1
Out (CA2) Cable
849040787
10
849040795
20
849040803
30
849040811
40
849040829
50
849040837
60
849040845
100
849040852
150
849040860
250
849040878
450
Ne to Ne Only
849041751
450
735/734 Splice
849041769
750
735/734 Splice
849041777
900
735/734 Splice
The following kits include 12 individually bagged BNCs with instructions plus one
spare:
KINGS 75ohm 735A
cable type (12)BNC
Plug Kit
848965778
KINGS 75ohm 734D
cable type (12)BNC
Plug Kit
848965786
TROMPETER
75ohm 735A cable
type (12)BNC Plug
Kit
848965794
TROMPETER
75ohm 734D cable
type (12)BNC Plug
Kit
848965802
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Right side cables for
function group D
and G
24 Cable DS3/EC-1
In (CA1) and 24
Cable DS3/EC-1 Out
(CA2) Cable
848940011
10
These cables route to the
right (as viewed from the
rear of the shelf) and
should be used with
connectors J1D (IN), J3D
(OUT) and J7G (IN), J9G
(OUT)
848940029
20
848940037
30
848940045
40
848940052
50
848940060
60
848940078
70
848940086
80
848940094
90
848940102
100
848940110
110
848940128
120
848940136
140
848940144
150
848940151
160
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-19
........................................................................................................................................................................
Cable and fiber installation
Right side cables for
function group D
and G
24 Cable DS3/EC-1
In (CA1) and 24
Cable DS3/EC-1 Out
(CA2) Cable
848940169
180
848940177
200
848940185
250
848940193
300
Ne to Ne Only
848940201
400
Ne to Ne Only
848940219
450
Ne to Ne Only
848939856
250
735A/734 Splice
848939864
300
735A/734 Splice
848939872
300
735A/734 Splice
848939880
325
735A/734 Splice
848939898
350
735A/734 Splice
848939906
375
735A/734 Splice
848939914
400
735A/734 Splice
848939922
425
735A/734 Splice
848939930
450
735A/734 Splice
848939948
750
735A/734 Splice NE to NE
848939955
900
735A/734 Splice NE to NE
Right side cables for
function group D
and G
similar to above
except no BNC’s are
shipped loose.
See below for
different vendors’
BNC Plug Kits.
849041108
10
These cables route to the
right (as viewed from the
rear of the shelf) and
should be used with
connectors J1D (IN), J3D
(OUT) and J7G (IN), J9G
(OUT)
849041116
20
849041124
30
849041132
40
849041140
50
849041157
60
849041165
70
849041173
80
849041181
90
849041199
100
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Right side cables for
function group D
and G
BNC’s are shipped
loose.
See below for
different vendors’
BNC Plug Kits.
849041207
110
These cables route to the
right (as viewed from the
rear of the shelf) and
should be used with
connectors J1D (IN), J3D
(OUT) and J7G (IN), J9G
(OUT)
849041215
120
849041223
140
849041231
150
849041249
160
849041256
180
849041264
200
849041272
250
849041280
300
Ne to Ne Only
849041298
400
Ne to Ne Only
849041306
450
Ne to Ne Only
849041892
250
735A/734 Splice
849041900
275
735A/734 Splice
849041926
300
735A/734 Splice
849041934
325
735A/734 Splice
849041942
350
735A/734 Splice
849041959
375
735A/734 Splice
849041967
400
735A/734 Splice
849041975
425
735A/734 Splice
849041983
450
735A/734 Splice
849041991
750
735A/734 Splice NE to NE
849042007
900
735A/734 Splice NE to NE
These kits include 25/50 individually bagged BNCs w/ assembly instructions
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-21
........................................................................................................................................................................
Cable and fiber installation
KINGS 75ohm 735A
cable type (24)BNC
Plug Kit
848963062
KINGS 75ohm 734D
cable type (24)BNC
Plug Kit
848963070
TROMPETER
75ohm 735A cable
type (24)BNC Plug
Kit
848963088
TROMPETER
75ohm 734D cable
type (24)BNC Plug
Kit
848963096
ITT CANON 75ohm
735A cable type
(24)BNC Plug Kit
409013554
ITT CANON 75ohm
734D cable type
(24)BNC Plug Kit
409013588
ITT CANON 75ohm
735A cable type
(50)BNC Plug Kit
409013562
ITT CANON 75ohm
734D cable type
(50)BNC Plug Kit
409013570
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Left side cables for
function group D
and G
DS3 (24PK) Cable
Assembly
849041788
250
735/734 Splice
849041793
275
735/734 Splice
849041801
300
735/734 Splice
849041819
325
735/734 Splice
849041827
350
735/734 Splice
849041835
375
735/734 Splice
849041843
400
735/734 Splice
849041850
425
735/734 Splice
849041868
450
735/734 Splice
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-23
........................................................................................................................................................................
Cable and fiber installation
Left side cables for
function group D
and G
Similar to above
except no BNC’s are
shipped loose.
See above for
different vendors’
BNC Plug Kits
849040886
10
These cables route to the
left (as viewed from the
rear of the shelf) and
should be used with
connectors J2D (IN), J4D
(OUT) and J8G (IN), J10G
(OUT)
849040894
20
849040902
30
849040910
40
849040928
50
849040936
60
849040944
70
849040951
80
849040969
90
849040977
100
849040985
110
849040993
120
849041009
140
849041017
150
849041025
160
849041033
180
849041041
200
849041066
250
849041074
300
Ne to Ne Only
849041082
400
Ne to Ne Only
849041090
450
Ne to Ne Only
848932083
250
735A/734 Splice
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Table 3-5
Twenty-four cable DS3/EC-1 transmission connections
Left side cables for
function group D
and G
Similar to above
except no BNC’s are
shipped loose.
See above for
different vendors’
BNC Plug Kits
848932018
275
735A/734 Splice
848932026
300
735A/734 Splice
848932034
325
735A/734 Splice
848932042
350
735A/734 Splice
848932059
375
735A/734 Splice
848932067
400
735A/734 Splice
848932075
425
735A/734 Splice
848839528
450
735A/734 Splice
Notes:
1.
All the DS3/EC-1 cable assemblies can be used for either function group D or G.
2.
Alcatel-Lucent 1665 DMXtend connectors J1D through J4D and J7G through
J10G can be used for either DS1/E1 or DS3/EC-1 cabling.
3.
Each Cable assembly # listed above contains two cable assemblies therefore a
quantity of two per function group in the case of the 24 pair cables, must be
ordered for the additional capacity.
4.
For Input connections use cable CA1 (DS3/EC-1 IN) and for Output connections
use cable CA2 (DS3/EC-1 OUT).
5.
735A cable is used to connect Alcatel-Lucent 1665 DMXtend to DSX-3 or
another NE (10 to 450 ft. length).
6.
The cable connectors are 62 pins D-Sub male-type connectors and fit into J1D
through J4D and J7G through J10G.
Coaxial
cable
Lead
designation
Name
Connector
pin#
Connectors
J1D (IN), J3D (OUT) and J7G (IN), J9G (OUT)
This cable routes to the right.
(Ports 1 - 24)
Description
Cable
assembly #
Cable
length
(feet)
Alcatel-Lucent 1665
DMXtend backplane
connections
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-25
........................................................................................................................................................................
Cable and fiber installation
1
DS3 1R/1T
Signal
40
FRG1
Ground
19
2
DS3 2R/2T
Signal
17
FRG2
Ground
38
3
DS3 3R/3T
Signal
57
FRG3
Ground
58
4
DS3 4R/4T
Signal
13
FRG4
Ground
34
5
DS3 5R/5T
Signal
53
FRG5
Ground
54
6
DS3 6R/6T
Signal
10
FRG6
Ground
31
7
DS3 7R/7T
Signal
51
FRG7
Ground
52
8
DS3 8R/8T
Signal
6
FRG8
Ground
27
9
DS3 9R/9T
Signal
47
FRG9
Ground
48
10
DS3 10R/10T
Signal
4
FRG10
Ground
25
11
DS3 11R/11T
Signal
24
FRG11
Ground
3
12
DS3 12R/12T
Signal
1
FRG12
Ground
22
13
DS3 13R/12T
Signal
59
FRG13
Ground
60
14
DS3 14R/12T
Signal
16
FRG14
Ground
37
Coaxial
cable
Lead
designation
Name
Connector
pin#
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
15
DS3 15R/12T
Signal
36
FRG15
Ground
15
16
DS3 16R/12T
Signal
55
FRG16
Ground
56
17
DS3 17R/12T
Signal
12
FRG17
Ground
33
18
DS3 18R/12T
Signal
32
FRG18
Ground
11
19
DS3 19R/12T
Signal
9
FRG19
Ground
30
20
DS3 20R/12T
Signal
49
FRG20
Ground
50
21
DS3 21R/12T
Signal
28
FRG21
Ground
7
22
DS3 22R/12T
Signal
5
FRG22
Ground
26
23
DS3 23R/12T
Signal
45
FRG23
Ground
46
24
DS3 24R/12T
Signal
43
FRG24
Ground
44
Connectors
J2D (IN), J4D (OUT) and J8G (IN), J10G (OUT)
This Cable Routes to the Left.
(Ports 25 - 48)
25
DS3 25R/12T
Signal
40
FRG25
Ground
19
26
DS3 26R/12T
Signal
17
FRG26
Ground
38
27
DS3 27R/12T
Signal
57
FRG27
Ground
58
Coaxial
cable
Lead
designation
Name
Connector
pin#
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-27
........................................................................................................................................................................
Cable and fiber installation
28
DS3 28R/12T
Signal
13
FRG28
Ground
34
29
DS3 29R/12T
Signal
53
FRG29
Ground
54
30
DS3 30R/12T
Signal
10
FRG30
Ground
31
31
DS3 31R/12T
Signal
51
FRG31
Ground
52
32
DS3 32R/12T
Signal
6
FRG32
Ground
27
33
DS3 33R/12T
Signal
47
FRG33
Ground
48
34
DS3 34R/12T
Signal
4
FRG34
Ground
25
35
DS3 35R/12T
Signal
24
FRG35
Ground
3
36
DS3 36R/12T
Signal
1
FRG36
Ground
22
37
DS3 37R/12T
Signal
59
FRG37
Ground
60
38
DS3 38R/12T
Signal
16
FRG38
Ground
37
39
DS3 39R/12T
Signal
36
FRG39
Ground
15
40
DS3 40R/12T
Signal
55
FRG40
Ground
56
41
DS3 41R/12T
Signal
12
FRG41
Ground
33
Coaxial
cable
Lead
designation
Name
Connector
pin#
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Table 3-6
Twelve cable DS3/EC-1 transmission connections
42
DS3 42R/12T
Signal
32
FRG42
Ground
11
43
DS3 43R/12T
Signal
9
FRG43
Ground
30
44
DS3 44R/12T
Signal
49
FRG44
Ground
50
45
DS3 45R/12T
Signal
28
FRG45
Ground
7
46
DS3 46R/12T
Signal
5
FRG46
Ground
26
47
DS3 47R/12T
Signal
45
FRG47
Ground
46
48
DS3 48R/12T
Signal
43
FRG48
Ground
44
Notes:
1.
Lead designation for EC1 connection for cable# x should be read as
EC1 xR/xT instead of DS3 xR/xT, where x is a number from 1 to 48.
Coaxial cable
Lead designation
Name
Connector pin#
Connectors
J1D (IN), J3D (OUT) and J7G (IN), J9G (OUT)
This Cable Routes to the Right.
(Ports 1 - 12)
1
DS3 1R/1T
Signal
40
FRG1
Ground
39
2
DS3 2R/2T
Signal
17
FRG2
Ground
18
3
DS3 3R/3T
Signal
57
FRG3
Ground
58
Coaxial
cable
Lead
designation
Name
Connector
pin#
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-29
........................................................................................................................................................................
Cable and fiber installation
4
DS3 4R/4T
Signal
13
FRG4
Ground
14
5
DS3 5R/5T
Signal
53
FRG5
Ground
54
6
DS3 6R/6T
Signal
10
FRG6
Ground
11
7
DS3 7R/7T
Signal
51
FRG8
Ground
50
8
DS3 8R/8T
Signal
6
FRG8
Ground
7
9
DS3 9R/9T
Signal
47
FRG9
Ground
46
10
DS3 10R/10T
Signal
4
FRG10
Ground
3
11
DS3 11R/11T
Signal
24
FRG11
Ground
23
12
DS3 12R/12T
Signal
1
FRG12
Ground
2
Note:
Lead designation for EC-1 connection for cable# x should be read as EC1 xR/xT
instead of DS3 xR/xT, where x is a number from 1 to 12.
Coaxial cable
Lead designation
Name
Connector pin#
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
DS1 and DS3 hybrid cable installation
Description
This section describes how to connect the DS1 and DS3 Hybrid cables to the Alcatel-
Lucent 1665 DMXtend shelf and route the cables out of the bay and to the DS1 and DS3
Hybrid Cable terminating equipment. Perform this procedure if DS1 and DS3 Hybrid
cables are required.
Note:
When cabling the Alcatel-Lucent 1665 DMXtend to a DSX, the DSX
becomes an extension of the Alcatel-Lucent 1665 DMXtend backplane connections.
Therefore, the IN on the Alcatel-Lucent 1665 DMXtend backplane connects to the IN
of the DSX and the OUT of the Alcatel-Lucent 1665 DMXtend backplane connects to
the OUT of the DSX respectively
DS1 and DS3 Hybrid cable options are listed in Table 3-7, “DS1 and DS3 hybrid cable
assemblies” (p. 3-33).
DS1 and DS3 Hybrid Cable transmission connections are in Table 3-9, “DS1 and DS3
hybrid cable DS1 transmission connections” (p. 3-35).
Steps
................................................................................................................................................
8
See the engineering job specification. Obtain the DS1 and DS3 Hybrid cables per
Table 3-7, “DS1 and DS3 hybrid cable assemblies” (p. 3-33) and note the function group
where each cable will be used. Label the cables, indicating bay, shelf, function group (A
and B) and direction (IN or OUT of the bay) at each end.
................................................................................................................................................
9
Connect the function group A/B cables at the Alcatel-Lucent 1665 DMXtend end,
carefully matching the correct connector with the appropriate backplane connectors as
shown in Figure 3-8, “DS1 and DS3 hybrid cable connections” (p. 3-31).
Note:
The DS1 and DS3 cable retaining screws must be tightened to a maximum of
6.5 in-lb. Do not overtighten.
Note:
The DS1 and DS3 Hybrid Cable only supports slots A1/B1 and A2/B2 and
only connects to J5A/B (IN) and J6A/B (OUT).
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
3-31
........................................................................................................................................................................
Cable and fiber installation
Figure 3-8
DS1 and DS3 hybrid cable connections
................................................................................................................................................
10
Route the cables along the backplane and out of the bay to the DSX per Figure 3-9, “DS1
and DS3 hybrid cable routing” (p. 3-31).
Figure 3-9
DS1 and DS3 hybrid cable routing
................................................................................................................................................
11
Route the DS1 cables along the cable rack and into the terminating bay (DSX-1 or other
terminating transmission equipment), and route the DS3 cables along the cable rack and
into the terminating bay (DSX-3 or other terminating transmission equipment).
................................................................................................................................................
12
Cut the coaxial cables to desired length and install the BNC connectors shipped with the
cable assemblies.
Alcatel-Lucent 1665 DMXtend
R10.0
365-372-327R10.0
Issue 1
January 2013
........................................................................................................................................................................
Cable and fiber installation
Note:
When installing BNC connectors, follow the manufacturer’s instruction
carefully to ensure a proper connection. Failure to do so may result in faulty DS3
signals as a result of improperly installed BNC connectors.
................................................................................................................................................
13
Referring to Table 3-8, “DS1 and DS3 hybrid cable DS3 transmission connections”
(p. 3-35) connect the cables to their respective positions on the terminating equipment or
DSX.
................................................................................................................................................
14
Remove slack and cut the DS1 cables to the desired length at the DSX.
................................................................................................................................................
15
Referring to Table 3-9, “DS1 and DS3 hybrid cable DS1 transmission connections”
(p. 3-35), carefully observe color codes and wire-wrap the cables at the DSX.
................................................................................................................................................
16
Check off the appropriate box in the Table I-2, Installation checklist.
........................................................................................................................................................
E N D O F S T E P S