Chore-Tronics® 2 Relative Humidity

Sensor Wiring (51663) The Relative Humidity Sensor comes with a quick connector and three feet of three conductor cord pre-wired to the sensor and Part A of the quick connector (Figure 1). The quick connect allows you to remove the sensor from the house between grow outs. Item Description 1 Quick Connect Part A 2 Quick Connect Part B 3 Electrical Cord (3’ x .75) 4 RH Sensor Figure 1. Introduction 1 2 MT2325A August 2008

Sensor Wiring (51663)

2 MT2325A Chore-Tronics 2® 12 Volt Wiring The Relative Humidity Sensor requires a three-conductor wire to connect the sensor to the Chore-Tronics 2 control. The sensor can be wired to any analog in terminal on the I/O board. The sensor can be supplied by 12 or 24 Vdc. (See Figure 2) Chore-Tronics 2® 24 Volt Wiring An AI terminal on the I/O board terminal block is wired to the #2 terminal on the relative humidity sensor quick connector Part B terminal block. The ground terminal next to the AI terminal is wired to the #3 and 12 or 24 Vdc is be wired to the #1 terminal. (See Figure 3) Quick Connect (Part B) Quick Connect (Part A) Figure 2. 12 Volt Wiring 24V AI5 AI6 AI7 AI8 A19 AI10 AI11 AI12 AO1 AO2 AO3 AO4 AO5 AO6 DI5 12V DI6 DI7 DI8 12V DI1 12V DI2 DI3 DI4 12V AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI8 A19 AI10 AI11 AI12 DI5 12V DI6 DI7 DI8 12V DI1 12V DI2 DI3 DI4 12V 1 3 2 Chore-Tronics 2 I/O Board Quick Connect (Part A 24V AI5 AI6 AI7 AI8 A19 AI10 AI11 AI12 AO1 AO2 AO3 AO4 AO5 AO6 DI5 12V DI6 DI7 DI8 12V DI1 12V DI2 DI3 DI4 12V AI1 AI2 AI3 AI4 24V AI5 AI6 AI7 AI8 A19 AI10 AI11 AI12 AI1 AI2 AI3 AI4 Quick Connect (Part B) Figure 3. 24 Volt Wiring Chore-Tronics 2 I/O Board 3 1 2

Sensor Wiring (51663)

MT2325A 3 Reinsert the terminal block into the Quick Connect part B housing and install the screw. (See Figure 4). Connect the two parts of the Quick Connect by sliding them into each other, and then close the latch. (See Figure 5) Connecting to Chore-Tronics® Models 16, 24, and 40 The Relative Humidity Sensor requires a three-conductor wire to connect the sensor to the Chore-Tronics Control. The Sensor wire is connected to the RH terminal on the I.O. board (See Figure 6). Figure 4. Inserting Terminal Block Figure 5. Latching Quick Connect RH + P #2 D #1 D #2 + S #2 S #3 S #4 S #5 S #6 3 2 1 Figure 6. ChoreTronics® Models 16,24,40 Wiring

Sensor Wiring (51663)

4 MT2325A 1. Do not get the Sensor Wet 2. Remove the Sensor before Cleaning out the House Caution, Warning and Danger Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety decals immediately. DANGER: Electrical Hazard Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically state otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment. CTB Inc. P.O. Box 2000 • Milford, Indiana 46542-2000 • U.S.A. Phone (574) 658-4101 • Fax (877) 730-8825 Email: [email protected] • Internet: http//www.ctbinc.com Attention!