Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985

The installer’s choice Receiver type: Supereheterodyne. Demodulation: AM/ASK. Operating frequency: 433.92 Mhz. Sensitivity ( for good signal ): -115 dBm. Input load: 50 Ohm. Power supply : 12 o 24 V ac/dc. Current consumption ( @12Vdc) from 25 mA to 90 mA (max) N° of relays: 2 (1 NO and 1NO / NC). Max power on relay output: 24VA max 60V . Memory capacity: 500 transmitters Security protocol Keeloq® Hopping code N° of code combinations 2exp64 Operating temperature: from -20 to + 70 °C. Dimensions ( Fig. 2): 120 x 80 x 40 mm Weight: 65 gr. Relay operating mode Pulse, step, timed Delay from 1 sec. to 24h: 59 min. The receiver Erone type XPL500 ( Fig. 1) is a single conversion superheterodyne receiver with integrated rolling-code decoding. The demodulation is AM/ASK. A special algorithm allows to keep synchronyzed transmitter and receiver. The receiver, having dry contacts relays output, can be connected to any type of device ( gate, garage door, rolling shutters, awnings, anti-burglar appliances, lighting, etc.). The transmitter memorization can be carried out either with 2 push-buttons of the receiver or remotely, using only the keys of the transmitter. The setup of the remaining parameters of the receiver can be done only with the 2 push buttons of the receiver. All the setting steps are displayed by a backlit LCD display. The internal data can be saved/restored to/from an external memory. 2 RELAY RECEIVER RX26-XPL5-GFA 2 Technical Specifications 3 Mounting www.erone.com - www.cdvigroup.com Fig.1 1 Introduction Option A ) make a hole ( ø11 mm ) on the bottom of the box and pass the cables throught Option B ) Use of Pg7 cable gland Drill the placing surface with ø6 tool and insert the 2 plugs Then fix the support with the screws provided F1001000082 Fig. 3 Fig. 2 Fig. 1 ERONE XPL500 ERONE XPL500 ERONE XPL500

Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985

The installer’s choice 4 Layout & Wiring GFA transmitters The receiver allocation is very important for the best operation of the system. Place the receiver far from interference sources such as big magnetic fields or radio emissions. The installation and the positioning of the antenna is very important as well. Before installing the antenna it’s advisable to make some tests on the site. The distance between 2 receiver must be at least 1,5m. The appliance full comply with the requirements of the following European Directives : 2006/95/CE, 2004/108/CE, 99/05/CE and the Standard EN 60335-1. 5 Compatible transmitters 6 Warnings 7 Display Legend There are 2 methods available: 1) Using P1 and P2 throughout the menu 2) Remote from the receiver, using a transmitter already in the receivers memory (Mode PLUS ). P1 : enter the menu ( 4 sec.) or confirm the choice P2 : navigate the menu 8 Programming / Navigation menu Button activated TX Serial number Relay activated The factory value for the timing is 1 sec. Use P1 to scroll the digits and P2 to confirm Relay 1 : Pulse Relay 1 : Step Relay 2 : Timed Menu Timed Add: Add transmitters s/n Delete TX : Delete a single transmitter, the button of a transmitter, a transmitter from a list , all transmitters Reset to factory default Info relays : Display relays operating mode, the number of Tx memorized, the of Transmitters, the SW release. Config relay 1 or 2 Set relay operating mode ( pulse , step, timed ) Set delay time of relay Backup to : data backup to an external memory Restore from : data restore from an external memory Plus ON : Enable remote transmitter memorization Plus Limited : Enable remote transmitter memorization only using a TX «ma- ster» ( see chapter 12 ) Plus OFF : disable remote transmitter memorization Connector for backup memory Backlit LCD Display Buzzer ERONE XPL500 www.erone.com - www.cdvigroup.com Fig. 5

Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985

The installer’s choice www.erone.com - www.cdvigroup.com 9 Menu Add (*) NOTE : The first TX added acts as Master: that means that it can be used to add more tx using the PLUS option. The submenu Add Master allows to assign the Master property to any other TX already in memory even not memorized on the first position. Once a TX has been assigned as Master, its property cannot be removed unless to delete it from the memory using the Delete menu. The transmitters «Master» are identified with the «#» in the list. 10 Menu Delete 11 Menu Info Delete TX : Delete a transmitter. It’s necessary to have the transmitter available because the system requires the RF transmission; Delete Button : Delete the single button of a transmitter; Delete by List : Delete a transmitter from a list. In this case it is enough to know the S/N of the transmitter to delete to complete the cancellation; Delete All TX : Delete all transmitters; Delete setting : Reset to factory default: delete all the transmitters and reset the operating mode of the relays to PULSE. For all the options, use P2 to scroll and P1 to confirm Info relays : Display relays operating mode Info N. Users : Display number of Tx memorized Info List : List of Transmitters Info Version : SW release. For all the options, use P2 to scroll and P1 to confirm Enter the number of TX [1 < n < 500] Push Button of the TX to store as Master (*) Push TX Button Push Button of the first TX Press the transmitter buttons which activate Relay 1 and press P1 to confirm Example: Relay 1 of the full block will be activated by buttons A and C Example: Relay 2 of the full block will be activated by buttons A,C and D Press the transmitter buttons which activate Relay 2 and press P1 to confirm Block memorization

The warranty period for this product is 12 months, beginning from the manufacturer date. During this period, if the product does not

work correctly, due to a defective component, the product will be repaired or substituted at our discretion. The guarantee does not cover the plastic container integrity. After-sale service is supplied at the factory. Fabricant de Contrôle d’Accès depuis 1985 Manufacturing Access Control since 1985 The installer’s choice 12 Menu Config 14 Memorization Plus 13 Backup / Restore (*) : Push the button of the new transmitter before the end of the beep. NOTE : If the option «PLUS LIMITED» is set, the transmitter which «opens» the memoriza- tion can be only the first transmitter memorized. If the option PLUS is OFF the remote memori- zation is disabled. If the option PLUS is ON the remote memoriza- tion of a new transmitter can be done using any transmitter already in memory. The memorization PLUS is active only if there is, at least, one transmitter in the memory. When the memory is empty, the memorization of the first transmitter can be effected only using the buttons P1 and P2. Memo TX on relay 1 Memo TX on relay 2 ! (*) Attention : this operation will overwrite all data of the internal memory Sold by : GfA ELEKTROMATEN UK Ltd, Agincourt Road, Warwick, CV34 6XZ, United Kindgom Tel : +44 (0) 1926 452 452 - Fax : +44 (0) 1926 336 417 www.gfa-elektromaten.co.uk Fig.4 Fig.5 Allows to set the operating mode of the relays R1 and R2, as Pulse, Step or Timed. In case of Timed it’s possible to set the delay time from 1 sec. to 24h: 59 min. Select PULSE, STEP or TIMED with P2 Set the desired delay time using P2 to scroll the digits and P1 to confirm and shift to next : the time is expressed in hours , minutes and seconds External Internal External Internal Save Restore (*) MEM. MEM. MEM. MEM. Allows to create a backup of the memory data base and save it onto an external memory ( fig. 6) Plug-in the memory in the proper receiver connector The memorization PLUS allows to add a new transmitter remotely, without using the push-buttons P1 & P2. It’s enough to use a transmitter «Master». A transmitter «Master» can be : 1) the first transmitter added; 2) any transmitter memorized and changed as «master» using the Add Master submenu ; The PLUS feature can be : ON, Limited or OFF Plus ON : remote transmitter memorization enabled; Plus Limited : remote transmitter memorization enabled only using a TX «master» ( see fig. 7-8 ); Plus OFF : remote transmitter memorization disabled; Fig. 7 Fig. 8 Fig. 6 ERONE XPL500