Cascade CD101 Quick Start Manual

Specifications

Brand: Cascade
Category: Controller
Model: CD101 (Quick Start Manual)
File Type: PDF
File Size: —
Pages: 6

Read Online

Read the Cascade CD101 Quick Start Manual online using the built-in PDF viewer.

Text of the manual

When in the SETUP MODE, pressing the “MAN”

(Manual) button steps up thru the entire list of parameters. The pattern of the top six LEDs, LEDs Bank 1 is used to indicate which parameter is selected. The pattern will change once each time the “MAN” button is pressed. Pressing the “OFF” button steps up thru all the available values for each parameter. The pattern of the bottom five LEDs, LEDs Bank 2 is used to indicate which value is selected. The pattern will change once each time the OFF button is pushed. Pressing the “AUTO” button stores the displayed value. LEDs Bank 1 LEDs Bank 2 Setting Up the Cascade To enter the SETUP Mode, first remove DC power to the Cascade controller for approximately 10 seconds. On the back of the controller are four DIP switches, set switch #1 to ON (see schematic at right) then restore DC power. The AUTO mode LED will blink to indicate that the Cascade is in the SETUP MODE. If any value is changed, it will blink until stored, except a value of zero. If any value is changed but not stored, and the parameter is changed, the value will still be what was shown originally. If you accidentally go past a desired parameter or value, you can step back by pressing the down arrow button. The complete parameter/value list and corresponding LED indication are shown on Table 1 – Parameter Values and Corresponding LED indication. (see pages 15- 18 of the Installation and Operations Manual) via the following link; Product Information (enovationcontrols.com). When you are finished with setup, set switch #1 to the Normal Operating Position (OPEN) remove DC power for 10 seconds, then restore DC power.

LED’s shown on the CD101 indicate the configuration value for parameter 32

shown from Top to bottom on the CD101. LED’s read from left to right on the Parameter list at top of page, a filled dot means LED is on.

Not all Parameters need to be changed.

Parameters that typically need to be changed include. Set the Flywheel Tooth Count in parameters 48,49,50 when Magnetic Pickup is selected. If application calls for Glow Plug Set parameter 7 Value and then set parameter 23 to preheat.

24 Volt systems will require changes

to parameters 42,43 and 44. 42 Low Batt Voltage Setpoint 43 High Batt Voltage Setpoint 44 Weak Batt Voltage Setpoint