BEKA BA684D Manual
Read Online
Read the BEKA BA684D Manual online using the built-in PDF viewer.
Text of the manual
Version 3.4 firmware
2. Operation
3. Applications
3.1
Legacy protocol
3.2
Modbus protocol
3.3
BEKA protocol
4. System Design
4.1
Power supply
4.2
Communication
4.3
Switch outputs
4.4
External switches
5. Installation
5.1
Location
5.2
Installation procedure
5.3
EMC
6. Configuration
6.1
Default configuration
6.2
Accessing the configuration menus
6.3
Summary of configurable functions
6.4
Quick access menu
7. Maintenance
7.1
Fault finding during commissioning
7.2
Fault finding after commissioning
7.3
Servicing
7.4
Routine maintenance
7.5
Guarantee
7.6
Customer comments
8. Accessories
8.1
Tag number
8.2
Pipe mounting kits
8.3
Serial Text Display - Programming
Guide.
8.4
Serial Text Display – Modbus
Guide
9. Index
Appendix 1
Getting Started Quickly
2
CONTENTS
The BA684D is CE marked to show compliance with the
European EMC Directive 2004/108/EC
The BA684D is a 24V dc powered instrument
which can display text and simple graphics in a
process area. Incorporating a backlit 120 x 64
pixel graphical display, four operator switches and
two solid state outputs, it is a versatile operator
interface for simple machine or process control
applications.
Housed in a robust IP66 glass reinforced polyester
(GRP) enclosure with an armoured glass window,
the BA684D is surface mounting, or may be pipe
mounted using one of the accessory kits.
The BA684D is available with an RS232 or with an
RS485 communication port.
1.1 Documentation
This instruction manual describes system design,
conditioning and installation of the BA684D serial
text display. If you wish to quickly install and
commission a BA684D for a basic application,
please read Appendix 1 Getting Started Quickly.
For detailed programming information separate
guides describe the Modbus and BEKA protocols.
These are available from our sales department or
may be downloaded from www.beka.co.uk.
Serial Text Display–Modbus Interface Guide
Description of parameters
Use with standard screens
Serial Text Display–Programming Guide
BEKA protocol
Command summary & reference
Scripting
Pattern matching
Advanced features
1.2 Version 3.4 Firmware
This manual describes the additional features
available in text displays employing version 3.4
firmware which was released in October 2009.
Namely:
Two eight variable standard screens added.
Integer variables added to the Modbus register
map to complement the original float values.
New function allows the number of process
variables to be entered, so that when scrolling
the display unused screens are not shown.
Enhancements to to the Scripting facility.
The instrument’s firmware version can be
established using the ‘Unit Info’ function in the
main configuration menu - see section 6.3 of this
manual. Text displays employing Version 3.4
firmware are backwards compatible with all earlier
versions.
2. OPERATION
Fig 1 shows a simplified block diagram of a
BA684D serial text display. Two versions are
available, one has an RS232 port and the other an
RS485 port. The type of port is shown on the
label fixed to the inside of the terminal cover.
The two switch outputs may be controlled and the
operator switches interrogated via the serial
communication link.
Fig 1 Simplified block diagram of BA684D
3. APPLICATIONS
The BA684D has been designed for easy
integration with most serial data sources and
therefore contains a wealth of features. Although
at first sight the complexity may seem daunting,
the support documentation is application related so
that only relevant sections need to be read. If
additional help is needed BEKA engineers are
always willing to assist with system design,
programming and screen development.
The BA684D may be used with three alternative
protocols; Legacy, BEKA or Modbus RTU. The
pattern matching function also enables proprietary
ASCII serial data, such as that from a weighing
system, to be decoded and displayed. This
advanced feature is described in the Serial Text
Display - Programming Guide.
3
3.1 Legacy protocol
The Legacy protocol contained in the BA684D
allows the instrument to replace an MTL643 IS text
display for safe area (non hazardous) applications.
The MTL643 uses proprietary two wire
communications generated by an MTL5051
galvanic isolator from an RS232 or RS422 safe
area port. A BA684D can therefore replace an
MTL643 display for safe area applications and
eliminate the need for an MTL5051 isolator. The
BA684D replicates all the functions of an MTL643
and has the advantage of a backlit display.
WARNING
The BA684D serial text display is not
intrinsically safe and must not be
installed in a hazardous area.
Legacy protocol only allows three external
switches S1, S2 & S3, not the front panel push-
buttons, to be used for operator inputs. Similarly,
the MTL643 only has one output control, so the
two BA684D switch outputs operate in parallel.
3.2 Modbus RTU protocol
The BA684D supports Modbus RTU protocol in
slave mode. Up to eight process variables,
together with their units of measurement and tag
descriptions may be displayed on one of the
eleven standard screen formats shown below.
These illustrate typical units of measurement and
tag information, but any may be entered. This
allows one, two, four or eight process variables to
be shown on a common screen without the need
for any programming, apart from setting the
BA684D address and writing each Modbus
variable in the required Modbus register address
map.
If more process variables than can be shown on
the selected standard screen are to be displayed,
the operator can select which process variables
are shown by operating the Up or Down push-
buttons. This selection can also be made by the
system host.
The Modbus protocol also enables each of the four
front panel push-buttons to be interrogated so they
may be used for operator controls. If larger
industrial size push-buttons are required, up to six
may be connected to the BA684D terminals.
When external switches are used the instrument
front panel switches are disabled.
The two single pole outputs may be independently
controlled for switching low power loads such as a
sounder, beacon or valve.
Modbus protocol is described in the Serial Text
Display – Modbus Guide, which is available from
the BEKA sales office and from the BEKA web site.
For more demanding applications BEKA protocol
may be used to construct custom display screens
for use in a Modbus system. See Serial Text
Display – Programming Guide which is available
from the BEKA sales office and from the BEKA
web site.
One variable
Two variables
Four variables
Eight variables
One variable + horizontal bargraph
Two variables + horizontal bargraphs
4
One variable + vertical bargraph
Two variables + vertical bargraphs
Three variables + vertical bargraphs
Four variables + vertical bargraphs
Eight variables + horizontal bargraphs
3.3 BEKA protocol
BEKA protocol enables text to be written anywhere
on the screen in five different font sizes, together
with lines, boxes and bargraphs. Alternatively one
of the nine standard display screens described in
section 3.2 may be used.
Simple bit map graphics may also be downloaded
to the display and all characters can be reversed or
flashed. Information may also be written to a
hidden screen that may be displayed when
required.
This protocol enables each of the four front panel
push-buttons to be interrogated so they may be
used for operator controls. By displaying the
switch function on the screen above the button,
‘soft switches’ can be created. If larger industrial
size push-buttons are required, these may be
connected to the BA684D terminals. When
external switches are used the front panel switches
are disabled.
The two single pole outputs may be independently
controlled for switching any small load such as
sounder, beacon or valve.
BEKA protocol is described in the Serial Text
Display – Programming Guide which is available
from the BEKA sales office and from the BEKA
web site.
5
4. SYSTEM DESIGN
Figure 1 shows a functional block diagram of
BA684D serial text display. Terminal locations are
shown in Fig 4.
4.1 Power supply
Any dc power supply having an output between 20
and 36 volts that is capable of supplying 95mA
may be used to power the BA684D. The power
supply output ripple must not cause the
instantaneous voltage to fall below 20V.
The BA684D does not have galvanic isolation
between the power supply, external switch and
serial communication terminals. If a common or
earthed supply is used, the communication port
and the optional external switches should only be
connected to electrically isolated circuits.
4.2 Communication
The BA684D serial text display is available with
either an RS232 or an RS485 communication port.
This is a factory set option that can’t be changed
on site. The type of port is shown on the label
fitted to the inside of the instrument terminal cover.
Fig 2 shows connections for both types of port.
Fig 2 RS485 & RS232 port connections
4.3 Switch outputs
The BA684D serial text display has two single pole
relay outputs which may be used for switching
small loads such as valves, actuators and
sounders.
The output relay contact rating must not be
exceeded.
240V
5A
1.25kVA
30V
5A
150W dc
When a reactive load is being switched by the
relay contact, it is essential that a suppresser is
fitted to prevent contact damage and radio
frequency interference. A 0.1µF capacitor in series
with a 100 resistor connected between the relay
contacts will usually provide adequate
suppression.
Proprietary
encapsulated
suppression assemblies can be purchased from
electrical suppliers. Please note that BEKA
associates’ guarantee excludes relay contact
damage.
WARNING
These switch outputs should not be
used for critical safety applications.
When the BA684D power supply is turned off or
disconnected, both switch outputs will open.
4.4 External switches
For applications requiring operator inputs to be
made by large industrial push-buttons, terminals
S1 to S7 allow six external switches to be
connected to the text display. When the external
push-buttons are enabled in the configuration
menu, the front panel push-buttons are
automatically disabled for operator inputs, although
they continue to function for instrument
configuration.
The external switch terminals are not isolated from
the BA684D power supply and communication
terminals. External switches should therefore be
floating, i.e. not earthed or connected to any other
circuits.
6
The BA684D serial text display is housed in a
robust IP66 glass reinforced polyester (GRP)
enclosure incorporating armoured glass window
and stainless steel fittings. It is suitable for exterior
mounting in most industrial environments, including
off-shore and waste water treatment installations.
Please consult BEKA associates if high vibration is
anticipated.
The BA684D enclosure is surface mounting.
Accessory kits described in sections 8.2 of this
manual enable the instrument to be mounted onto
a vertical or horizontal pipe.
The field terminals and the two mounting holes are
located in a separate compartment with a sealed
cover allowing the instrument to be installed
without exposing the display assembly.
The BA684D earth terminal is connected to the
internal EMC filters. For maximum radio frequency
interference rejection this terminal should be
connected to a local earth.
The BA684D enclosure is supplied with a bonding
plate to ensure electrical continuity between the
three conduit / cable entries.
5.2 Installation Procedure
Fig 3 illustrates the instrument installation
procedure.
a.
Remove the instrument terminal cover by
unscrewing the two captive 'A' screws.
b.
Mount the instrument on a flat surface and
secure with two M6 screws through the 'B'
holes. Alternatively use one of the mounting
kits described in section 8.2
c.
Remove the temporary hole plug and install
an appropriate IP rated cable gland or
conduit fitting. If more than one entry is
required, one or both of the IP66 stopping
plugs may be replaced with an appropriate IP
rated cable gland or conduit fitting.
d.
Connect the field wiring to the terminals as
shown in Fig 4.
e.
Replace the instrument terminal cover and
evenly tighten the two 'A' screws.
Fig 3 BA684D installation procedure
5.3 EMC
The BA684D complies with the requirements of the
European EMC Directive 2004/108/EC. For
specified immunity all wiring should be in screened
twisted pairs and one of the BA684D earth
terminals should be locally earthed.
To prevent circulating currents, cable screens
should only be earthed at one point.
7
Before the BA684D can be commissioned it must
be configured to be compatible with the host’s
communications format and to have the required
functions enabled.
The BA684D is configured via the four front panel
push-buttons. All the configuration functions are
contained in an easy to use menu shown in Fig 5.
Where necessary the sub-menus contain on-
screen prompts to guide the user through each
adjustment.
When navigating through the configuration menu,
the push-button(s) should be held until the required
screen is displayed.
6.1 Default configuration
Unless otherwise requested at time of ordering,
BA684D text displays will be supplied configured
as follows:
Baud rate
9.6k
Data bits
8
Stop bit
1
Parity
None
Protocol
BEKA
Address
0
Operational mode
1
Keypad
Internal
Display brightness
100%
Display contrast
50%
Quick access menu
On
Show Status Text
On
Set Last Valid Input
8
Quick access menu code
0000
Configuration menu
access code.
0000
Key Mode
0
Screens
Text Display
6.2 Accessing the configuration menus
Throughout this manual push-buttons are shown in
italics e.g. P or Up push-button, and legends
displayed by the instrument are shown within
inverted commas e.g. 'Please enter code'.
The configuration menu is accessed by operating
the P and E push-buttons simultaneously. If the
BA684D is not protected by an access code the
main menu will be displayed. If an access code
other than the default code 0000 has already been
entered, the BA684D will request that the access
code be entered.
Using the Up or Down button set the first digit of
the code which will be flashing. Pressing P will
transfer control to the next digit which should be
adjusted in the same way. When all four digits
have been set, pressing the E button will enter the
access code.
If the code is correct the main menu will be
displayed, if the code is incorrect ‘Invalid code’ will
be displayed.
When entering an access code, timeout will occur
and the instrument will automatically return to the
operating mode ten seconds after the push-buttons
were last operated. In all other menus timeout
occurs after thirty seconds.
When the main menu is displayed the required
sub-menu can be highlighted by scrolling through
the menu using the Up or Down push-button.
Operating the P push-button will display the
highlighted sub-menu from which a further
selection may be made. After a configuration
parameter has been adjusted, pressing the E
button will enter the selection and move the display
up one level.
After the instrument configuration has been
completed, operating the E push-button repeatedly
will return the instrument display to the main menu.
One more operation of the E button will then return
the BA684D to the operating mode.
6.3 Summary of configurable functions
This section provides a brief explanation of each
configurable function and should be read in
conjunction with Fig 5.
View settings
Displays the instruments main communication
settings. Adjustments can not be made from
this sub-menu.
Baud rate
Range depends upon type of port. For RS485,
data rate may be set to one of ten speeds
between 0.3 and 115.2kbaud. For RS232,
data rate limited to one of seven rates between
0.3 and 19.2kbaud.
Data bits
7 or 8 data bits may be selected. 8 bit data is
required in BEKA mode for graphics, for error
checked modes and for Modbus.
Stop bits
1 or 2 stop bits may be selected
Parity
An even, odd or no parity bit may be selected.
Protocol
BEKA, Legacy or Modbus protocol may be
selected. The Legacy protocol is compatible
with the MTL643.
9
Each text display must be allocated a unique
address within the following ranges:
Modbus protocol 1 – 247
BEKA protocol
0 – 247
Zero reserved for
Legacy protocol 0 –15
single unit applications.
Op Mode
Five different levels of communications security
to be selected, ranging from immediate
execution of a command with no
acknowledgement, to a requirement for a 16 bit
cyclic redundancy check. See the Serial Text
Display - Programming Guide for a detailed
explanation.
Not available with Legacy protocol.
Key mode
Key press data can be returned in three ways.
See Response Format Section in the Serial
Text Display - Programming Guide. Not
applicable with Legacy protocol.
Keypad
This function allows the instrument front panel
push-buttons or external push-buttons to be
used for operator inputs. Whichever are
selected, the instrument front panel push-
buttons are used for configuration.
This function is not available when Legacy
protocol is selected.
Settings
Allows the backlight brightness and contrast of
the BA484D display to be adjusted.
Screens
One of nine standard screens or a custom
screen may be selected.
Not applicable with Legacy protocol.
Quick access
This function enables the quick access menu
described in section 7.4. When ‘On’ is selected
an operator can adjust the screen brilliance and
contrast without having access to other
conditioning parameters.
Access code for the Quick Access Menu
‘Access Code’ in the display menu defines the
four digit alphanumeric code that must be
entered to gain access to the instrument’s quick
access menu. Alpha characters are case
sensitive. Default code 0000 allows direct
access without a code.
Status Text
The two single variable screens include a
message ‘Status: Good or Status: Bad’, the
Status Text function allows this message to be
inhibited.
Variable Color
The background color of variables depends on
the IN_X Status Coils. ‘Status: Good or Status:
Bad’ set a normal or inverted color on the
variable’s background. 'For further information
regarding status please refer to the "Data
Status" paragraph on page 8 of "Modbus
Interface Guide" or page 16 of the
"Programming guide”
Last Valid Input
This function allows the number of process
variables to be entered so that when scrolling
the display unused screens are not shown.
Access code for the Configuration Menu
‘Code’ in the main menu defines the four digit
alphanumeric code that must be entered to gain
access to the instrument configuration menus.
Alpha characters are case sensitive. Default
code 0000 allows direct access without a code.
Unit information
Displays the instrument model number and the
firmware version.
Configuration defaults
‘Default’ allows the configuration default defined
in section 6.1 to be globally set.
6.4 Quick Access Menu
The quick access menu allows an operator to
adjust the backlight brilliance and the display
contrast without having access to the other
configuration parameters.
The quick access menu is accessed by operating
the P and Up push-buttons simultaneously. If the
quick access menu is not protected by an access
code the brilliance and contrast controls will be
displayed immediately. If an access code other
than the default code 0000 has already been
entered, the BA684D will request that the access
code be entered. Section 6.2 explains how an
access code should be entered.
The backlight brilliance is adjusted using the Up
and Down push-buttons. Operating the P push-
button will transfer control to the display contrast
adjustment. When both are set as required
operating the E button will store both settings and
return the instrument to the operating mode.
1
7.1 Fault finding during commissioning
If a BA684D fails to function during commissioning
the following procedure should be followed:
Symptom
Cause
Check:
No Display
No Power
Incorrect wiring
Earth fault
That there is 20
to 36 volts
between
terminals 1 and 2
of the six way
terminal block.
Terminal 1
should be
positive.
That comms
signal & extrnal
switches are
floating.
No
Communication
Communications
parameters
incorrectly set
Input port, baud
rate, data bits,
stop bits and
parity settings
match those of
the host.
Incorrect
Protocol
Protocol settings
in “Comms”
Menu
Incorrect wiring
Wiring is as
installation
diagram.
Address incorrect
Address setting
in “Comms”
menu
Poor
Communication
Communication
cable too long.
Communication
speed too fast.
Configuration
settings.
Installation
guidlines
Dark Display
Contrast too high
Contrast level in
“Display Settings”
menu
No Backlight
Brilliance setting
too low
Brightness level
in “Display
Settings” menu
Cannot enter
configuration
menu
Keys not held for
long enough (up
to 2 seconds
required)
Menu inhibited
Send
“Configuration
Enable”
command
(BEKA protocol)
Restart unit
(Legacy protocol)
7.2 Fault finding after commissioning
ENSURE PLANT SAFETY BEFORE
STARTING MAINTENANCE
If a BA684D fails after it has been functioning
correctly, the table shown in section 7.1 may help
to identify the cause of the failure.
If this procedure does not reveal the cause of the
fault, it is recommended that the instrument is
replaced.
7.3 Servicing
We recommend that faulty BA684D serial text
displays are returned to BEKA associates or to our
local agent for repair.
7.4 Routine maintenance
The mechanical and electrical condition of the
instrument should be regularly checked. Initially
annual inspections are recommended, although
the inspection frequency should be adjusted to suit
the environmental conditions.
7.5 Guarantee
Instruments which fail within the guarantee period
should be returned to BEKA associates or our local
agent. It is helpful if a brief description of the fault
symptoms is provided.
7.6 Customer comments
BEKA associates is always pleased to receive
comments from customers about our products and
services. All communications are acknowledged
and whenever possible, suggestions are
implemented.
1
8.1 Tag number
The BA684D can be supplied with a blank or
custom engraved stainless steel plate secured by
two screws to the side of the instrument enclosure.
This plate can accommodate:
1 row of 9 alphanumeric characters 10mm high
or 1 row of 11 alphanumeric characters 7mm high
or 2 rows of 18 alphanumeric characters 5mm
high
8.2 Pipe mounting kits
Two pipe mounting kits are available for securing
the BA684D to a horizontal or vertical pipe.
BA392D Stainless steel bracket secured by two
worm drive hose clips for 60 to 80mm
outside diameter pipes.
BA393
Heavy duty stainless steel bracket
secured by a single 'V' bolt. Will clamp
to any pipe with an outside diameter
between 40 and 80mm.
8.3 Serial Text Display - Programming
Guide
A detailed guide to programming the BA684D
serial text display using BEKA protocol may be
requested from the BEKA sales office or
downloaded from the BEKA website at
www.beka.co.uk.
8.4 Serial Text Display – Modbus Guide
This guide explains how to use the BA684D serial
text display as a slave in Modbus RTU systems. It
may be requested from the BEKA sales office or
downloaded from the BEKA website at
www.beka.co.uk.
1
Structure Fig 5
Quick access menu
6.4
Data bits
6.3
Display settings
6.3
EMC
5.3
External switches
4.4
Fault finding
During commissioning
7.1
After commissioning
7.2
Getting Started Quickly Appendix 1
Guarantee
7.5
Installation
5.2
Key mode
6.3
Keypad
6.3
Legacy protocol
3.1
Location
5.1
Subject
Section
Maintenance
7.
Routine
7.4
Modbus
3.2
MTL643 display
3.1
Operational mode
6.3
Parity
6.3
Power supply
4.1
Protocol
3, 6.3
Quick access menu
6.3, 6.4
Access code
6.3
RS232 port
4.2 Fig 2
RS485 port
4.2 Fig 2
Servicing
7.3
Standard screens
3.3
Stop bits
6.3
Switch outputs
4.3
Terminal numbers Figs 1, 2 & 4
Timeout
6.2
Unit information
6.3
View settings
6.3
1
Getting Started Quickly
This appendix provides simple step-by-step
instructions to get a BA684D Serial Text Display
functioning quickly.
Communication
1.
Connect dc power supply to the BA684D as
shown in Fig 4.
2.
Connect the serial communication port as
shown in Fig 2 .
Note: The BA684D serial text display is
available with either an RS232 or RS485
communication port. The port type is shown
on the label fixed to the inside of the
instrument terminal cover.
3. Apply power.
4. The BA684D will display the model number,
type of communication port and firmtware
details for a few seconds before reverting to the
BEKA logo.
5. To set the instrument’s basic communications
parameters enter the configuration menu by
pressing the
P
and
E
push-buttons
simultaneously. Fig 5 shows the menu
structure and navigation.
The P button enters a menu, the Up and Down
buttons select the required sub-menu or setting
and the E button enters the selection and
moves the display up one level.
The following menu items must be configured
before use:
Parameter Select
Baud Rate
Comms. speed
Data Bits
7 or 8 data bits
Stop Bits
1 or 2 stop bits
Parity
Even, odd or none
Protocol
BEKA, Legacy or
Modbus.
Address
Range depends on
protocol:
Modbus
1 to 247
BEKA
0 to 247
Legacy
0 to 15
The host and BA684D Serial Text Display should
now be able to communicate.
Modbus protocol
Using Modbus RTU and one of the eleven
standard screens is the easiest way to display
process variables on a BA684D serial text display.
Select one of the standard screens shown in
section 3.3 from the ‘Screens’ sub-menu.
Modbus register addresses for the instrument are
shown in the BEKA Serial Text Display – Modbus
Interface Guide, which is available from the BEKA
sales office or from www.beka.co.uk
BEKA protocol
Please refer to the BEKA Serial Text Display –
Programming Guide which is available from the
BEKA sales office or from www.beka.co.uk
1