C.A. Technologies Panther 200C Product Information
Read Online
Read the C.A. Technologies Panther 200C Product Information online using the built-in PDF viewer.
Text of the manual
CONVENTIONAL AIR CAP AND FLUID NOZZLE CHART
MODEL
NO.
AIR CAPS
Press /
Siphon
*SUGGESTED
GUN INLET
PRESS.
FAN
CONTROL
SCFM
AIR CAP
RING
AVAILABLE FLUID
NOZZLES
NEEDLES /
marking on needle
22-2030
siphon
50
12
22-2058
p & s
40
6
32-0611 1.1mm (.042")
40-1211 (211)
22-2080
siphon
60
14
32-0614 1.4mm (.055")
40-1214 (214)
22-2062**
pressure
80
19
32-0618 1.8mm (.070")
40-1218 (218)
22-2064**
pressure
80
22
32-0618V 1.8mm (.070")
40-5301
22-2704
pressure
70
21
32-0818 1.8mm (.070")
22-2765
pressure
80
22
32-0622 2.2mm (.086")
22-2777
pressure
70
23
32-0622V 2.2mm (.086")
40-5301
22-2797
pressure
70
21
32-0628 2.8mm (.110")
40-1228 (228)
22-2880
siphon
60
15
included
32-0628V 2.8mm (.110")
40-5301
22-2900
siphon
45
12
22-1001
Actual fluid nozzle and air cap combinations are determined by application (see application chart page 4)
*Gun inlet pressures may vary as required by application
**Air caps available with teflon coating (22-2062T & 22-2064T)
40-1222 (222)
P200C
60-1500
included
22-1001
Panther 200C
Panther 200C
Panther 200C
Panther 200C
Panther 200C
PRESSURE/SIPHON FEED SPRAY GUN
PRODUCT INFORMATION
Coating Atomization Technologies 337 South Arthur Avenue, Louisville CO 80027 Phone: 888.820.4498, Fax: 303.438.5708
www.spraycat.com
Operation and Maintenance Instructions for P
PP
PP200C
200C
200C
200C
200C Spray Guns
Operation
1. Connect air supply hose at handle of gun.
2. Connect a pressurized fluid supply or paint siphon cup to the gun fluid inlet.
3. Fluid flow can be controlled using the fluid control knob, this restricts flow by limiting needle travel. It is best to control
fluid flow by proper selection of fluid orifice size and use the fluid control knob to “fine tune flow rate”.
4. Fan width can be adjusted using the fan control knob. Turning the knob clockwise narrows the fan.
Maintenance
IMPORTANT! Routine cleaning and maintenance is essential to insure proper gun operation.
Several states prohibit spraying solvent into the atmosphere and require the use of covered gun cleaner.
1. If a gun cleaner is being used, connect and clean the gun in the gun cleaner according to the manufactures
instructions.
2. If a gun cleaner is not being used:
Remove air cap and clean separately using clean solvent.
For pressure setups, connect a pressurized solvent supply to the fluid inlet, trigger the gun allowing solvent to flow
thru the gun until clean.
For siphon setups, first clean the siphon cup thoroughly then spray clean solvent thru the gun until clean.
NOTE: Gun head disassembly is not recommended for normal cleaning and maintenance.
Gun head disassembly and reassembly instructions:
Have repair kit # 10-110 available before gun disassembly.
Gun head disassembly
To remove the nozzle carrier (5) and air cap adapter (6):
1. Remove the air cap (1), fluid nozzle tip (2), fluid nozzle body (3), and needle (13).
2. Remove the needle seal cartridge (23).
3. Loosen the locknut (9) and remove fluid inlet (10) using a 5/8” open-end wrench.
4. The nozzle carrier (5) and air cap adapter (6) will now slide forward from the gun body (11).
Gun head reassembly
1. Install a new o-ring (7) on the air cap adapter (6).
2. Install o-ring (4) between fluid nozzle body (3) and fluid nozzle carrier (5).
3. Install the thread locknut (9) onto the fluid inlet (10) as far as possible.
4. Install a new fluid inlet seal (8) into the recess area on the nozzle carrier (5) inlet port.
5. Slide the nozzle carrier (5) into air cap adapter (6) and insert into the gun body (11) as far as possible. Be sure the
nozzle carrier (5) extends into the hole at the back of the gun head. Install the needle seal (23) but do not tighten.
6. Rotate the nozzle carrier (5) until the fluid inlet port in the nozzle carrier (5) is aligned with the threaded hole in the
body. While in this position, insert the fluid inlet (10) and tighten firmly.
7. Tighten the needle seal (23) to approx. 12 ft.-lb. torque.
8. Tighten the fluid inlet (10) to approx. 25 ft.-lb. torque.
9. Tighten the locknut (9) to approx. 33 ft.-lb. torque.
See Air Cap Chart
Air Cap**
16
60-206
Needle Return Spring (HD)*
2
See Air Cap Chart
Fluid Nozzle Tip**
17
60-201
Rear Bushing
3
32-2201
Fluid Nozzle Body
18
60-119
Seal*
4
98-8020
Gasket*
19
60-1520
Air Valve Assembly
5
60-L21C
Nozzle Carrier
20
60-302
Air Valve Poppet
6
60-22
Air Cap Adapter
21
60-125
O-Ring*
7
60-131
O-Ring*
22
61-1003
Air Valve Spring*
8
60-124
Fluid Inlet Seal
23
60-1400
Needle Seal Cartridge*
9
60-128
Locknut
24
60-2101
Trigger
10
60-126
Fluid Inlet Fitting
25
60-1510
Air Control
11
60-1125
Panther Gun Body Conventional
25A
60-122
Plug (optional)
12
See Air Cap Chart
Fan Control Assembly**
26
60-104
Air Inlet Fitting
13
See Air Cap Chart
Fluid Needle**
27
60-1033
Trigger Pivot Set
14
60-202
Fluid Control Knob
28
98-0109
Allen Plug
15
60-209
Spring Seat*
**See air cap selection chart on page 1
*Indicates part included in repair kit # 10-110
*
*
*
*
*
*
*
*
*
P200C CONVENTIONAL SPRAY GUN
MATERIAL TYPE
FLUID ORIFICE x
AIR CAP
MAXIMUM
PATTERN WIDTH
PRESS. / SIPHON
Very Thin
less than 16 sec. Zahn #2
inks , dyes,
solvents, stains
Thin
16 to 20 sec. Zahn #2
lacquers, enamels,
primers, sealers
Medium
21 to 30 sec. Zahn #2
automotive base coat
enamels, primers
epoxies, urethanes
automotive clear coat
Heavy
over 30 sec. Zahn #2
heavy body primers
high solid enamels
high solid automotive coatings
adhesives
FLUID NOZZLE / AIR CAP SELECTION CHARTS
PANTHER Series 200C - Pressure / Siphon Feed Guns
1.1 mm x 2058
1.1 mm x 2030
9
10
P/S
S
1.8mm x 2765
1.8mm x 2797
2.2 mm x 2880
2.2 mm x 2064
15
17
13
14
P
P
S
P
1.1, 1.4 mm x 2058
1.1, 1.4 mm x 2030
1.1, 1.4 mm x 2900
9
10
10
P/S
S
S
1.4, 1.8 mm x 2080
1.4, 1.8 mm x 2704
1.4, 1.8 mm x 2765
1.4, 1.8 mm x 2777
1.4, 1.8 mm x 2797
1.4, 1.8 mm x 2900
13
12
15
14
17
10
S
P
P
P
P
S