Bard WG241D Installation Instructions Manual

File Specifications

Brand: Bard
Category: Furnace
Model: WG241D (Installation Instructions Manual), pr.D9j.y1OiTY
File Info: Adobe Acrobat PDF (DjVu)
File Size:
Pages: 79 pages

Download PDF

Download Bard WG241D Manual (79 pages)

Read Online:

Read the Bard WG241D Installation Instructions Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

1. Air Filters – Check the condition at least monthly

when the unit is in use, and replace as necessary. 2. Lubrication Requirements – The indoor circulating air blower motor and outdoor circulating air fan motor are permanently lubricated and require no re- oiling. The combustion air blower motor requires no re-oiling. ROUTINE INSPECTION 1. Inspect the physical support of the unit annually to make sure it is securely fastened to the building. Also look for any obvious signs of deterioration. 2. Inspect the main burners at the beginning of each ...

FOR WG24, WG30, AND WG36

39 3/16" 29 3/4" 4 11/16" 12" 12" 12" 12" 12" 12" 2" 2 1/4" 10" 28 5/16" 15" 27" 17 15/16" 11 5/16" 8 5/8" 2 15/16" 2 1/4" 30" 29" 5 1/16" 7/16" 5 9/16" 4 9/16" 4 1/2" 2 15/16" 18 15/16" 4 9/16" SUPPLY AIR DUCT RETURN AIR DUCT Ø2 3/4" GAS OPENING (OPTIONAL) Ø2 3/4" HIGH VOLTAGE (OPTIONAL) Ø2" LOW VOLTAGE (OPTIONAL) (12) FLANGE SCREWS UNIT SUPPORT 1" MIN. NECCESSARY NO CLEARANCE SUPPLY AIR DUCT RETURN AIR DUCT CONTROL PANEL VESTIBULE DOOR WALL STRUCTURE (OUTSIDE) 1" CLEARANCE ON ALL FOUR SIDES OF SUPPLY AIR DUCT ...

WG481 INDOOR BLOWER PERFORMANCE @ 230 AND 460 VOLTS

Recommended WG481 cooling airflow range at rated 1550 CFM @ .38 ESP (WC) is 1750 - 1280 CFM Factory set on High Speed for cooling and Medium Speed for heating. Voltage adjustment – Reduce airflow by 130 CFM for 208 Volt Top outlet adjustment – Increase airflow by 65 CFM for top outlet models SG-5, RG-5, non-ducted application adjustment – Reduce airflow by 170 CFM for SG-5 and RG-5 installations ESP Inches HsO COOLING MODE MANUAL FAN and EATING MODE H Wet Co li 125,000 BTU Input 12,500 BTU Input 1 High ...

INTEGRATED FURNACE AND BLOWER CONTROL OPERATION

GNITION SEQUENCE CONTROL I itin on Source gI 4 VAC DSI 2 F al me Sen is ng emote R mings iT - - - - - - - - - - - - - - Prepurge Po ts purge la purge irt-r tnI e Pressure sw cti h pro iv ng pe ir od itin on for ig sla T ir itin on fla or ig T ir itin on sequence ol cko tu gI olb wer on - d ale y Heat olb wer o ff - d ale y Heat olb wer on - d ale y Co lo olb wer o ff - d ale y Co lo fla an opera it ons anu M lo opera it on High il m ti co rtn tu sw cti h opera it on ollo al me r F 15 30 15 60 3 7 60 - 30 90, 7 0 ...

Bard WG241D user guide recommended for: WA421, FUSION-TEC HR58APB, 8620-343, HAC181-AD040, Q-TEC Series.

⚠️ Download Safety

The Furnace Installation instructions manual (79 pages) is completely safe to download (last scan date: 13/02/2026).

Related PDF Instructions for Bard WG241D:

Furnace Equipment: Frequently Requested

Have some Questions about Bard WG241D Device?

Get valuable and actionable advices from other Bard WG241D device users. Describe your problem or question, regarding the using of Bard WG241D, in as much detail as possible, and other users will be able to answer you.