SystemAir SYSVRF2 Installation Manual

Brand: SystemAir
Category: Air Conditioner
Model: SYSVRF2 (Installation Manual)
File Type: PDF
File Size: —
Pages: 15
Text of SystemAir SYSVRF2 Installation Manual

SystemAir SYSVRF2 Please read this installation manual carefully before installation.

The air conditioner must be installed by qualified service person. If the supply cord is damaged,it must be replanced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. When installing the indoor unit , please follow this manual as strictly as possible. Check the piping is accomplished perfectly before electrifying the unit. This ma

SystemAir SYSVRF2 3. Unit structure introduction

Please avoid installing in the following places A place with flammable gas or material. A saline place such as a seashore vicinity A place with sulphur gas. A place with oil gas, such as kitchen. A place with high-humidity air. An unbearable place. A place where high-frequency waves are generated. The appliance shall not be installed in the laundry. Plea

The handling to the ceiling varies from the constructions, consult

the construction person for the specific condition. The size of the ceiling to be handled------ Do keep the ceiling flat. Consolidate the roof beam for possible vibration. Cut off the roof beam. Strengthen the place that has been cut off, and consolidatethe roof beam. Connect wires and pipes inside the ceiling after the air conditioner is hanged. After the select

Panle installation bolt: M4X22

24mm Panel component installation (take 18-36 as an example, operation method of 45-71 are the same.) Remove the air return grille, filter screen, screw hidden cover. As the grille switch arrow indication direction to pull the lock catch, remove the air return grille. Pull the buckle as figure display, remove the filter screen. Open the air leading bar, remove three screw hidden

SystemAir SYSVRF2 Install the screw

Before installation please check the connecting cable etween panel and air conditioner whether has clamped, if clamped, the panel will be unfairness after fastening the screws and damage the wires. Fig.5-14 Fig.5-15 Fig.5-16 Install the screw hidden cover Install back the filter screen and the air return grille Screw hidden cover Panel component wiring must accord to the figure display, otherwise will cause the abnormal ope

Please according to the tube hardness to choose proper

support density, do not appear obvious dropping and deformation situation. Dropping part will save the water and lead to poor drainage and abnormal noise. Drainage system design requirement Drainage pipe can use PVC pipe, recommended to use the pipe of 25 mm inner diameter, water pipe should has thermal insulation layer. The user can purchase the pipe of suitable length in the dealer pl

Locate The Pipe

Drill a hole in the wall (suitable just for the size of the wall conduit, 90mm in general), then set on the fittings such as the wall conduit and its cover. Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air in, which will cause water leakage by condensation. Pass the bound connecting pipe through the wall conduit from outside. Be careful of the pipe all ocation to do no damage to the tubi

Use a vacuum pump, to vacuum from the gas side refrigerant

adding mouth of the outdoor unit. Don’t use the refrigerant of the outdoor unit to do the vacuum. (A certain volume of refrigerant had been added into the outdoor unit in factory.) Open/Close the valves Open/Close the spools or the valves of outdoor unit with a f5mm hexagon spanner. Leakage Test Test if there is any leakage on the connections of the pip

The reserved function is indicated in broken line table,users can

select it when necessary. CAUTION Terminal board diagram Please refer to the indoor unit wiring diagram for the wiring. NOTE The air-conditioners can connect with Centralized Control Monitor (CCM).Before running the system, ensure the wiring is correct and set the system address and network address for Indoor unit power supply and the signal wire wiring The indoor unit power source should no

SystemAir SYSVRF2 Signal wire for communicate

indoor unit and outdoor unit Grounding line Grounding line Outdoor power supply RCCB RCCB Fig.9-4 Indoor Unit Wiring Guideline 10 installation manual Panel control/ display box wire Panle wind deflector motor wire Wind deflector motor wire cable plug connects to the CN21 of the main control panel Motor wire should goes through this gap to enter the

SystemAir SYSVRF2 10. CONTROL OPERATION

Base on different purposes to setting the switch cords on PC panel of indoor electrical control box. Once finish the setting, please cut off the main power, and then input power again, otherwise, setting function could not work. Network address is set by communication of indoor and is no need to set separately. There are maximum 64 indoor units in one refrigerant system,and each of them should occupy one uni

SystemAir Air Conditioner Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
SYSAER R32 SR R32 105

SYSAER R32 SR R32 105 (Air Conditioner ePDF Manual, #75X7O2)

79 643 142 30-08-2026
Danvent DV

PDF User Manual (@38K4MT), SystemAir Danvent DV Air Conditioner (02-09-2026)

36 870 218 02-09-2026
SAVE VTR 300/B

SAVE VTR 300/B (Air Conditioner ePDF Guide, #X1Y5AB)

25 1489 283 05-07-2026
SAVE VTC 300

SAVE VTC 300 (Air Conditioner ePDF User Guide, #91SJF2)

18 1338 201 27-04-2026

Air Conditioner: Similar Manuals