MULTI ACCESS VIDEO AND AUDIO SERVER
MAV-2000
INPUT AND OUTPUT PROCESSOR BOARD
BKMA-2010
INSTALLATION MANUAL
1st Edition
Serial No. 10001 and Higher: MAV-2000
Serial No. 10001 and Higher: BKMA-2010
This manual is intended for qualified service personnel only.
To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that
contained in the operating instructions unless you are qualified to do so. Refer all servicing to
qualified service personnel.
! WARNUNG
Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt.
Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die
Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei
Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben
Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung
dazu besitzen.
! AVERTISSEMENT
Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin
de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les
réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres.
Pour toute réparation faire appel à une personne compétente uniquement.
Attention-when the product is installed in Rack:
1. Prevention against overloading of branch circuit
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
make sure that the rack does not overload the supply
circuit.
2. Providing protective earth
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
confirm that the outlet is provided with a suitable
protective earth connection.
3. Internal air ambient temperature of the rack
When this product is installed in a rack, please make
sure that the internal air ambient temperature of the
rack is within the specified limit of this product.
4. Prevention against achieving hazardous
condition due to uneven mechanical loading
When this product is installed in a rack, please make
sure that the rack does not achieve hazardous
condition due to uneven mechanical loading.
WARNING
This unit has no power switch on the front panel.
When installing the unit, incorporate a readily
accessible disconnect device in the fixed wiring, or
connect the power cord to a socket-outlet which must be
provided near the unit and easily accessible, so that the
user can turn off the power in case a fault should occur.
WARNUNG
Dieses Gerät hat keinen Netzschalter über vor panel.
Beim Einbau des Geräts ist daher im Festkabel ein
leicht zugänglicher Unterbrecher einzufügen, oder das
Netzkabel muß mit einer in der Nähe des Geräts
befindlichen, leicht zugänglichen Wandsteckdose
verbunden werden, damit sich bei einer
Funktionsstörung die Stromversorgung zum Gerät
jederzeit unterbrechen läßt.
Use the specified power cord only
Use of power cords other than the specified ones may
cause fire or electric shock.
Do not damage the power cord
A damaged power cord may cause fire or electric shock.
When mounting the unit in a rack, be careful not to
catch the power cord in the rails.
Do not install the unit in humid or dusty locations
Dust, soot, and oil particles in the ambient atmosphere
may cause fire or electric shock.
Install the dedicated circuit breaker or power switch
This unit is not equipped with a main power switch on
the front panel.
Install the dedicated circuit breaker or power switch,
and/or plug the power cord in the outlet.
Do not block the ventilation slots
If the ventilation slots are blocked, overheating inside
the unit may cause fire. Observe the following points to
ensure adequate ventilation.
. Do not install in narrow or sealed locations.
. Remove dust from the fan and air filter.
Install in a stable location
Installation in an unstable place may cause the unit fall,
resulting in injury.
Do not stack the units
Do not stack two or more units on top of each other.
Mount in a rack to avoid the risk of the unit sliding and
causing injury.
Ground the unit safely
Failure to ground the unit may cause electric shock.
Handling the unit with the handgrip
Handling the unit without the handgrip may cause the
unit fall off, resulting in injury.
Carry the unit with more than two persons
The total weight of this unit is 50 kg.
Carrying the unit with less than two persons may cause
injury.
Mount with more than two persons
The total weight of this unit is 50 kg.
Mounting the unit with less than two persons may cause
injury.
Mount only with the specified support angles
Support angles other than those specified for this unit
may not be strong enough to support the unit, risking
possible collapse and injury.
Secure the unit to a rack with the screws
If the unit is not secured completely, this may cause the
unit fall off, resulting in injury. Be sure to secure the unit
with the screws when mounting to the rack. (Refer to
“1-5 Rack Mounting”)
Table of Contents
Manual Structure
Purpose of this manual ........................................................................................ 3 (E)
Related manuals................................................................................................... 3 (E)
Contents ............................................................................................................... 3 (E)
Trademark............................................................................................................ 3 (E)
1.
Installation
1-1.
Installation Procedure............................................................................1-1 (E)
1-2.
Operating Conditions and Installation Space ........................................1-2 (E)
1-3.
Power Supply ........................................................................................1-4 (E)
1-3-1.
Information for Power Supply .............................................1-4 (E)
1-3-2.
Recommended Power Cord..................................................1-4 (E)
1-4.
Installation of Option Boards ................................................................1-5 (E)
1-4-1.
Installation of BKMA-2010 .................................................1-5 (E)
1-5.
Rack Mounting ......................................................................................1-7 (E)
1-6.
Signal Input and Output ........................................................................1-9 (E)
1-7.
Connecting Connectors and Cables ....................................................1-10 (E)
1-8.
Connection ..........................................................................................1-11 (E)
1-9.
Checks after Connection .....................................................................1-13 (E)
1-9-1.
Checking MAV-2000 .........................................................1-13 (E)
1-9-2.
Checking BKMA-2010 ......................................................1-13 (E)
1-9-3.
Error Display ......................................................................1-13 (E)
2.
Service Overview
2-1.
Cleaning the Air Filter ..........................................................................2-1 (E)
2-2.
Functional Descriptions of Board Switches and LEDs .........................2-2 (E)
2-2-1.
TM-37 Board........................................................................2-2 (E)
2-2-2.
FM-62 Board ........................................................................2-4 (E)
2-2-3.
IF-741 Board ........................................................................2-6 (E)
2-2-4.
IF-742 Board ........................................................................2-7 (E)
2-2-5.
DM-119 Board (BKMA-2010) ............................................2-8 (E)
Purpose of this manual
This manual is the installation manual of the MAV-2000 Multi Access Video and
Audio Server.
This manual is intended for use by trained system and service engineers, and
describes the information regarding installation.
Related manuals
Besides this Installation Manual, the following manuals are available for the
MAV-2000.
..... MAV-2000 Operation Manual (supplied with the MAV-2000)
This manual describes the application and operation of the MAV-2000.
..... MAV-2000 Maintenance Manual (available on request)
This manual describes the information that premise the service based on main
parts replacement (upgrading, self-diagnostics, replacement of the parts and
boards, electrical alignment, and circuit descriptions, etc.).
If this manual is required, please contact your local Sony Sales Office/Service
Center.
Contents
The following is a summary of all the section for understanding the contents of this
manual.
Section 1
Installation
Explains the operating conditions, installation space, power supply, installation of
option boards, rack mounting, connection, and checks after installation.
Section 2
Service Overview
Explains the cleaning procedure of the air filter, the function and factory setting of
the switches and LEDs on the board.
Trademark
Trademarks and registered trademarks used in this manual are follows.
. Ethernet is a registered trademark of Xerox Corporation.
Manual Structure
The installation procedure of the MAV-2000 is shown in the following flowchart.
Refer to each item in this manual for details.
This unit is supplied with the following parts.
Plug Holder
3 pcs
Ornamental Washer
4 pcs
Screw (RK5 x 14)
4 pcs
Operation Manual
1 pc
Installation Manual
1 pc
Start
Determination
of Installation Space
Rack Mounting
Installation of
Option Boards
Connection
Initial Settings
Checks after Connection
End
1-2. Operating Conditions
and Installation Space
1-3. Power Supply
1-5. Rack Mounting
1-4. Installation of Option Boards
1-6. Signal Input and Output
1-7. Connecting Connectors and Cables
1-8. Connection
Initial Settings Using Supplied Software
System Phase Adjustment (BKMA-2010)
1-9. Checks after Connection
To be published soon
Operating Conditions and Installation Space
Operating Conditions
Operating temperature
+5 dC to +40 dC
Performance humidity
20 % to 90 % (No condensation)
Mass
MAV-2000 :
Approx. 41 kg
BKMA-2010 : Approx. 2.4 kg (per one set)
To prevent overheating of the MAV-2000 ensure that there is good air circulation around the unit.
w
Do not install the unit in humid or dusty environment.
c
Do not stack the units.
1-2. Operating Conditions and Installation Space
Do not block ventilation.
Both of the front and rear sides must be at least 30 cm away and both sides must be at least 20 cm away
from the walls for ventilation and maintenance.
Do not stop the fan or block the ventilatior because this unit is air-cooled by the fan on the side view of
the unit and the power supply. If not, a fire or failure may occur.
1-2. Operating Conditions and Installation Space
482
650
37.5
37.5
19.1
13.6
187.5
166.9
354.4 (8U)
279.4
661
667
465
424
387
498
67
55
161.7
141
141
105.3
47
27
Unit : mm
1-3. Power Supply
1-3.
Power Supply
1-3-1. Information for Power Supply
Power voltage
: 100 to 240 V AC
Power frequency
: 50/60 Hz
Power consumption
: Max. 800 W
Current consumption : 8 A (at maximum load)/120 V
3.4 A (at maximum load)/240 V
Rush Current
: 120 V IN : 49 A (0-peak)
240 V IN : 34 A (0-peak)
w
This unit has no power switch on the front panel.
When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect
the power cord to a socket-outlet which must be provided near the unit and easily accessible, so that the
user can turn off the power in case a fault should occur.
1-3-2. Recommended Power Cord
For customers in the U.S.A. and Canada.
Required Part
1
Power Cord, 125 V 13 A (2.5 m) : !1-558-527-11
2
Plug Holder
:
3-613-640-01 (Supplied Accessory)
For customers in the United Europe.
Required Part
1
Power Cord, 250 V 10 A (2.5 m) : ! 1-782-929-11
2
Plug Holder
:
3-613-640-01 (Supplied Accessory)
w
. Use the specified power cord only.
. Do not damage the power cord.
c
. Ground the unit safely.
. For a distributor box in the electrical system, use appropriate one with enough capacity for the rush
curent mensioned above.
Connect the power cord to the outlet directly without using an extension cord.
n
For the customers outside the area as shown above. Please consult with local Sony’s sales/service office.
1
2
AC inlet
(MAV)
1
2
AC inlet
(MAV)
Safety earth (Green/Yellow)
Live (Brown)
Neutral (Blue)
1-4. Installation of Option Boards
1-4.
Installation of Option Boards
1-4-1. Installation of BKMA-2010
General Information for Installation
. When you want to install the BKMA-2010, install it into
the slot (such as slot 1, slot 1X, slot 1Y or the like) that
correctly corresponds the front and rear of the
MAV-2000. (Refer to the inscription on the front and
rear panel indication.) Also, install the BKMA-2010
starting from the topmost slot in this order.
. Do not open the slots to maintain the cooling effect of
this unit.
Be sure to attach blank panels to vacant slots.
. There are no adjustments to be made after installing the
board.
Installation Procedure
1.
Turn off the main power of this unit.
2.
Remove the sixteen fixing screws from the blank
panels and remove all the blank panels 2U/4U.
n
Keep the removed blank panel.
3.
Insert the BKMA-2010 (DPR board) into the slot and
push in the handles on the board in the direction of the
arrow to connect the board to the mother board
completely.
.�
.�
.�
.�
.�
.
MAV-2000 (rear side)
1X slot
1Y slot
6X slot
6Y slot
BVTT3 x 6
BVTT3 x 6
BVTT3 x 6
BVTT
3 x 6
Blank panels 4U
Blank panels 2U
Handle
Handle
DPR board
Rear side
Option slot
Front side
Option slot
1X
1Y
2X
2Y
6X
6Y
1
2
6
IF IN
IF OUT
TM
FM
..........
..........
............
............
MAV-2000 (side view)
1-4. Installation of Option Boards
4.
Fix the BKMA-2010 using the two screws that were
securing the blank panel and the supplied two screws.
5.
Attach the BKMA-2010 (DPR board) in the same way.
6.
Change the combination of the blank panels so that all
slots are not released.
7.
Fully loosen the three screws (with drop-safe) and
open the front panel.
8.
Remove the eight screws (PSW3 x 6) and remove the
board fixing plate.
BVTT3 x 6
BVTT3 x 6
Blank panels 4U
Blank panel 2U
RK4 x 16
PSW3 x 6
Front panel
Board fixing plate
9.
Insert the BKMA-2010 (DM board) into the slot. Push
in the board in the direction of the arrow to connect it
to the mother board completely.
10. After connecting the board, push the levers in the
direction of the arrow to lock them.
11. Attach the board fixing plate.
12. Unlock the stopper on the front panel, close the front
panel, and tighten the three screws (with drop-safe).
Lever
Lever
DM board
Stopper
Stopper
Install the unit in a stable location.
If the unit is mounted on a unstable table or slant bench,
the unit can fall and result in physical injury.
c
Use the specified support angle.
If the parts other than the specified one are used, the unit
can fall and results in physical injury.
This unit can be mounted in a 19-inch standard rack of EIA
standard. To mount the unit in the rack use the specified
support angle kits and parts.
n
Mount the unit in the rack with the HDD removed from the
unit.
Specified rack mount kit : RMM-2000 (option)
Constituent parts
. Outer Support Assembly
2 pcs
Outer Support
2 pcs
Bracket
4 pcs
Screw (B4 x 12)
8 pcs
Inner Support
2 pcs
. Plate Nut
4 pcs
. Screw (B4 x 12)
16 pcs
The following parts are supplied for rack mounting.
. Screw (RK5 x 14)
4 pcs
. Ornamental Washer
4 pcs
n
Standard Tightening Torque
Screw Size
Standard Tightening Torque
M3.0
0.7 to 1.0 N.m (7 to 10 kgf.cm)
M4.0
1.2 to 1.6 N.m (12 to 16 kgf.cm)
1-5. Rack Mounting
1.
If there is any equipment with an HDD installed in the
rack and the main power on, turn off the main power.
2.
Remove the four screws from the side of the unit, lift
up the unit and remove the four foot holder assemblies.
3.
Remove the 10 screws on the side of the unit and
attach the inner support to the side of the unit using the
removed screws.
B4 x 8
Foot holder
assembly
B4 x 8
B4 x 8
Inner supports
Tighten completely all the screws loosened in step 4
and tightened temporarily in step 5.
7.
Install the unit into the rack in such a manner that the
inner support comes on top of the outer support of the
rack.
c
Be sure to mount the equipment in the rack with two
persons or more.
If only one person mounts the equipment in the rack,
backache or injury may result and the equipment may fall.
1-5. Rack Mounting
4.
Loosen the four screws of the outer support assembly
to slide the bracket.
5.
Attach the outer support assembly to the rack tempo-
rarily.
B4 x 12
B4 x 12
Bracket
Bracket
Outer support assembly
B4 x 12
12.7
12.7
31.75
Outer support
Nut plate
Bracket
Rack side
The projected side
should face up.
Unit : mm
Outer support
Bracket
Inner support
Rack side
Main unit
After installing the rack into the unit, fix the rack angle
on the rack using the supplied ornament washers and
the screws.
c
Tighten the screws of the rack angle completely.
If the screws are not tightened, the unit may slip from the
rack and fall, causing injury.
1-5. Rack Mounting
1-6. Signal Input and Output
1-6.
Signal Input and Output
The input and output signals of each connector on the
connector panel are as follows:
ETHER : 10BASE-T (8-pin Modular jack)
Pin No.
Signal
1
TX +
2
TX _
3
RX +
4-5
_
6
RX _
7-8
_
REMOTE : RS-422A (D-sub 9-pin, Female)
Pin No.
Signal
1
GROUND
2
OPERATE
3
WARNING
4
ERROR
5
_
6
_
7
_
8
_
9
GROUND
RK5 x 14
RK5 x 14
Ornament washers
1
8
5
1
6
9
1-7. Connecting Connectors and Cables
1-7.
Connecting Connectors and Cables
When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following
connectors/cable or their equivalents.
Connector of the MAV-2000 Side
Matching Connector and Recommended Cable
Print on Panel
Connector Type
Connector/Cable Type
Sony Part Number
TC IN
BNC
BNC
1-508-083-11
AUDIO IN
BNC 75 Z
BNC 75 Z
1-569-370-12
AUDIO OUT
SDI IN
BNC 75 Z
BNC 75 Z
1-569-370-12
SDI OUT
BELDEN 8281 cable *1)
SBX
BNC 75 Z
BNC 75 Z
1-569-370-12
IN
BELDEN 8281 cable *2)
OUT
REF. VIDEO
BNC 75 Z
BNC 75 Z
1-569-370-12
VS-BUS
BELDEN 8281 cable *1)
STATUS OUT
D-sub 9-pin, female
D-sub 9-pin, male
1-560-651-00 (Connector)
RCC-5G, 10G, 30G (cables)*3)
1-561-749-00 (Shell)
ETHER-1, 2
(10Base-T)
RJ45
UTP (Unshielded twisted-pair) cable
REMOTE
D-sub 9-pin, female
D-sub 9-pin, male
1-560-651-00 (Connector)
RCC-5G, 10G, 30G (cables)*3)
1-561-749-00 (Shell)
*1) : BELDEN 8281 cable (Max. 200 m) or the equivalent.
*2) : BELDEN 8281 cable (Max. 20 m) or the equivalent.
*3) : These cables are available as optional accessories. The length of the cables are 5 m, 10 m and 30 m respectively.
Connect the MAV-2000 to the hard disk drive array units (abbreviates to RAID) MAV-S2000 as shown here:
n
The rotary switch and the piano switch of MAV-S2000 are located behind the cover shown in Fig. 1. Remove the screw
and the cover before switching them.
Connection to the MAV-S2000 (single mode)
ID
SET UP
HDD array unit (1)
MAV-S2000
HDD array unit (2)
MAV-S2000
1
4
Fig. 1
Cover
B3 x 6
Rotary SW
Set the first switch
to the “1” position.
1
SBX
OUT 1
SBX
IN 1
SBX IN 1
SBX
OUT 1
SBX
IN 1
BNC cable
BNC cable
BNC cable
BNC cable
SBX IN2
SBX OUT1
SBX OUT2
Multi access
video/audio server
MAV-2000
4bit piano switch
.Single mode : bit 1 DOWN
.Terminal : bit 4 DOWN
1
4
4bit piano switch
.Single mode : bit 1 DOWN
.Terminal : bit 4 DOWN
Rotary SW
Set the first switch
to the “1” position.
1
Connection to the MAV-S2000 (dual mode)
ID
SET UP
HDD array unit (1)
MAV-S2000
HDD array unit (2)
MAV-S2000
1
4
Fig. 1
Cover
B3 x 6
1
4
1
BNC cable
BNC cable
BNC cable
Multi access
video/audio server
MAV-2000
SBX IN4
SBX IN3
SBX IN2
SBX IN1
SBX OUT4
SBX OUT2
SBX OUT1
SBX IN2
SBX IN1
SBX OUT2
SBX OUT1
SBX IN2
SBX IN1
SBX OUT1
SBX OUT2
SBX OUT3
Rotary SW
Set the first switch
to the “1” position.
1
Rotary SW
Set the first switch
to the “1” position.
4bit piano switch
.Dual mode : bit 1 UP
.Center : bit 4 DOWN
4bit piano switch
.Dual mode : bit 1 UP
.Terminal : bit 4 DOWN
1-9. Checks after Connection
1-9.
Checks after Connection
After installing the unit, check to see the lighting operation of the following LEDs to determine whether
the system is get up and running normally or not.
n
Ensure that the unit is under the following conditions before checking of the LEDs’ operation.
. The RAIDs connected to the MAV-S2000 are get up and running.
. The REF VIDEO connector of the MAV-2000 receives a signal with a connected cable.
1-9-1. Checking MAV-2000
7-seg LEDs’ Operation
Board
Ref.No. (Address)
Type
Color
Operation
TM-37
ND201 (L-5)
7-seg LED
_
Outer segments flash cyclically
FM-62
ND401 (A-7)
7-seg LED
_
Outer segments flash cyclically
Front Panel Indicators’ Operation
Status Indicator
Color
Operation
POWER A
green
Turns on
POWER B
green
Turns on
POWER C
green
Turns on
BUSY
Amber
Flashes or turns off
SYSTEM
green
Turns on
1-9-2. Checking of BKMA-2010
LEDs’ Operation
Board
Ref.No. (Address)
Type
Color
Operation
DM-119
ND401 (L-5), ND402 (L-6)
7-seg LED
_
All segments of the 7-segment LED on the
left flash cyclically
1-9-3. Error Display
The 7-segment displays of the TM-37 board, FM-62 board and DM-119 board remain at “E1” during
startup, and errors will be detected by the self-diagnostics of each board.
Clear the error referring to the Maintenance Manual, Section “2-4. Error Messages”.
RK4 x 16
Filter (B)
Filter (A)
Stopper
Stopper
2-1.
Cleaning the Air Filter
A filter is fitted on the rear side of the front panel assembly
of the unit. If accumulated dust on the filter impedes the
flow of air, the inside may heat up and troubles may occur.
Clean the filter periodically.
Cleaning
1.
Turn off the main power of the MAV-2000.
2.
Fully loosen the three screws (with drop-safe).
3.
Open the front panel assembly in the direction of the
arrow.
4.
Press the stopper in the direction of the arrow to lock
the front panel.
5.
Remove the filter (A) and filter (B).
6.
Remove the dust from the filter using a vacuum.
7.
Attach the filter in reverse order of the disassembly
procedure.
8.
Unlcok the stopper and close the front panel.
Functional Descriptions of Board Switches and LEDs
2-2-1. TM-37 Board
(Side A/component side)
Switches
n
Do not change the setting of the “Factory use” switches.
Ref. No.
Address
Name
Function
Factory setting
S201
(L-7)
Abort switch
For debug
_
S202
(L-7)
Reset switch
Initializes the TM-37 board
_
S203
(L-6)
Test switch
Factory use
2-2. Functional Descriptions of Board Switches and LEDs
A
B
C
D
E
F
G
H
J
K
L
1
2
3
5
4
6
7
8
9
S201
S202
S203
ND201
D201
D202
D203
D204
D205
D206
D207
D208
D703
D702
D701
OPEN
1
2
3
4
5
6
7
8
2-2. Functional Descriptions of Board Switches and LEDs
LEDs
Ref. No.
Address
Indication color
Name
Function
Normal state
D201
(L-5)
Green
_
Turns on with REF LOCK
_
D202
(L-5)
Green
_
Turns on when REF video is input
_
D203
(L-5)
Green
_
Turns on during interrupt of the dual port RAM
Turns off
D204
(L-6)
Green
_
Not used
Turns off
D205
(L-6)
Green
_
Time Slot (LSB)
Flashes
D206
(L-6)
Green
_
Time Slot
Flashes
D207
(L-6)
Green
_
Time Slot
Turns off
D208
(L-6)
Green
_
Time Slot (MSB)
Turns off
D701
(L-3)
Green
_
Turns on when Ether is used for test
Turns off
D702
(L-3)
Green
_
Turns on when Ether is used for test
Turns off
D703
(L-2)
Red
_
Turns on when Ether is used for test
Turns off
ND201
(L-5)
_
_
Flashes clockwise during normal run
Flashes
2-2. Functional Descriptions of Board Switches and LEDs
2-2-2. FM-62 Board
(Side A/component side)
Switches
n
Do not change the setting of the “Factory use” switches.
Ref. No.
Address
Name
Function
Factory setting
S401
(A-3)
Abort switch
For debug
_
S402
(A-9)
All reset switch
Initializes the MAV-2000
_
S403
(A-3)
Reset switch
Initializes the FM-62 board
_
S404
(A-4)
Test switch
Factory use
S401
S403
S404
ND401
S402
3
2
1
A
B
C
D
E
F
G
H
J
7
6
5
4
8
9
10
D401
D402
D403
D404
D405
D406
D407
D408
OPEN
1
2
3
4
5
6
7
8
Shows the state of SBX SDRAM
D402
(A-6)
Green
_
D403
(A-6)
Green
_
Turns on during interrupt of the dual port RAM
Turns off
D404
(A-6)
Green
_
Flashes when battery (BT1001) runs out
Turns off
D405
(A-5)
Green
_
Turns on when SBX gate is open
Turns off
D406
(A-5)
Green
_
Not used
Turns off
D407
(A-5)
Green
_
Not used
Turns off
D408
(A-5)
Green
_
Time Slot (LSB)
Flashes
ND401
(A-7)
_
_
Flashes clockwise during normal run
Flashes
D401
D402
Turns off
Turns off : CPU mode
Turns on
Turns off : Status Sense mode
Turns off
Turns on : Get mode
Turns on
Turns on : Put mode
2-2. Functional Descriptions of Board Switches and LEDs
2-2-3. IF-741 Board
(Side A/component side)
Switches
n
n
n
n
n
Do not change the setting of the “Factory use” switches.
Ref. No.
Address
Name
Function
Factory setting
S801
(J-11)
Test switch
Factory use
LEDs
Ref. No.
Address
Indication color
Name
Function
Normal state
D502
(K-11)
Green
CH1
Turns on when SBX SYNC is detected
Turns off
D503
(K-11)
Green
CH3
D504
(K-12)
Green
CH5
D505
(K-12)
Green
CH7
D506
(K-11)
Green
CH2
D507
(K-11)
Green
CH4
D508
(K-12)
Green
CH6
D509
(K-12)
Green
CH8
2-2. Functional Descriptions of Board Switches and LEDs
A
B
C
D
E
F
G
H
J
K
L
M
1
2
3
4
5
6
7
8
9
10
11
12
S801
D502
D506
D503
D507
D504
D508
D505
D509
ON
1
2
3
4
5
6
7
8
2-2. Functional Descriptions of Board Switches and LEDs
2-2-4. IF-742 Board
(Side A/component side)
Switches
n
n
n
n
n
Do not change the setting of the “Factory use” switches.
Ref. No.
Address
Name
Function
Factory setting
S801
(F-12)
Test switch
Factory use
S802
(E-11)
PLL ADJ
Enters the PLL ADJ mode
Mode switch
S802-1, 2: Turns on simultaneously
LEDs
Ref. No.
Address
Indication color
Name
Function
Normal state
D202
(G-11)
Green
CH1
Turns on when BINGO SLOT is “E”
Turns off
D203
(G-12)
Green
CH3
D204
(G-12)
Green
CH5
D205
(G-12)
Green
CH7
D206
(G-12)
Green
CH2
D207
(G-12)
Green
CH4
D208
(G-12)
Green
CH6
D209
(G-12)
Green
CH8
A
B
C
D
E
F
G
H
J
K
L
M
S801
S802
D202
D206
D203
D207
D204
D208
D205
D209
1
2
3
4
5
6
7
8
9
10
11
12
ON
1
2
3
4
5
6
7
8
ON
1
2
2-2. Functional Descriptions of Board Switches and LEDs
2-2-5. DM-119 Board (BKMA-2010)
(Side A/component side)
Switches
n
Do not change the setting of the “Factory use” switches.
Ref. No.
Address
Name
Function
Factory setting
S401
(L-8)
Abort switch
For debug
_
S402
(L-7)
Reset switch
Initializes the DM-119 board
_
S403
(L-7)
Test switch
Factory use
A
B
C
D
E
F
G
H
J
K
L
ND401
D801
D802
D803
ND402
S403
S401
S402
1
2
3
4
5
6
7
8
9
D1001
D1002
D1003
D1004
D1005
D1006
D1007
D1008
D1009
OPEN
1
2
3
4
5
6
7
8
2-2. Functional Descriptions of Board Switches and LEDs
LEDs
Ref. No.
Address
Indication color
Name
Function
Normal state
D801
(L-2)
Green
_
Turns on when Ether is used for test
Turns off
D802
(L-2)
Green
_
D803
(L-1)
Red
_
D1001
(L-9)
Green
_
Flashes when PLD runs normally
Flashes
D1002
(L-8)
Green
_
D1002 : Turns on by reset
Flashes
D1003
(L-8)
Green
_
D1003 : Turns on during interrupt of the dual port RAM
Flashes
D1004
(L-8)
Green
_
Ch#X BingoTomeslot display
Flashes during recording or playback of Ch#X port
Turns off while Ch#X port is waiting
D1005
(L-8)
Green
_
Ch#Y BingoTomeslot display
Flashes during recording or playback of Ch#Y port
Turns off while Ch#Y port is waiting
D1006
(L-8)
Green
_
Ch#X SBX Memory Write display
Turns on when Ch#X port is recording
Flashes when Ch#X port is in playback
Turns off while Ch#X port is waiting
D1007
(L-8)
Green
_
Ch#X SBX Memory Read display
Turns on when Ch#X port is recording
Flashes when Ch#X port is in playback
Turns off while Ch#X port is waiting
D1008
(L-8)
Green
_
Ch#Y SBX Memory Write display
Turns on when Ch#Y port is recording
Flashes when Ch#Y port is in playback
Turns off while Ch#Y port is waiting
D1009
(L-8)
Green
_
Ch#Y SBX Memory Read display
Turns on when Ch#Y port is recording
Flashes when Ch#Y port is in playback
Turns off while Ch#Y port is waiting
ND401
(L-5)
_
_
Rotates during normal operation (left half)
(7-seg)
ND402
(L-6)
_
_
Rotates during normal operation (left half)
(7-seg)
The material contained in this manual consists of
information that is the property of Sony Corporation.
Sony Corporation expressly prohibits the duplication of
any portion of this manual or the use thereof for any
purpose other than the operation or maintenance of the
equipment described in this manual without the express
written permission of Sony Corporation.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation.
Sony Corporation interdit formellement la copie de
quelque partie que ce soit de ce manuel ou son emploi
pour tout autre but que des opérations ou entretiens de
l’équipement à moins d’une permission écrite de Sony
Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als
die Bedienung oder Wartung der in dieser Anleitung
beschriebenen
Ausrüstung
ohne
ausdrückliche
schriftliche Erlaubnis der Sony Corporation.
Printed in Japan
Sony Corporation
1999. 11 16
B&P Company
©1999
BKMA-2010 (SY)
MAV-2000 (SY) J, E
3-203-539-01