MULTI ACCESS VIDEO AND AUDIO SERVER

MAV-2000 INPUT AND OUTPUT PROCESSOR BOARD BKMA-2010 INSTALLATION MANUAL 1st Edition Serial No. 10001 and Higher: MAV-2000 Serial No. 10001 and Higher: BKMA-2010

This manual is intended for qualified service personnel only.

To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. ! WARNUNG Die Anleitung ist nur für qualifiziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifiziertem Fachpersonal ausgeführt werden. Um die Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung dazu besitzen. ! AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit. 2. Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the rack, please confirm that the outlet is provided with a suitable protective earth connection. 3. Internal air ambient temperature of the rack When this product is installed in a rack, please make sure that the internal air ambient temperature of the rack is within the specified limit of this product. 4. Prevention against achieving hazardous condition due to uneven mechanical loading When this product is installed in a rack, please make sure that the rack does not achieve hazardous condition due to uneven mechanical loading. WARNING This unit has no power switch on the front panel. When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power cord to a socket-outlet which must be provided near the unit and easily accessible, so that the user can turn off the power in case a fault should occur. WARNUNG Dieses Gerät hat keinen Netzschalter über vor panel. Beim Einbau des Geräts ist daher im Festkabel ein leicht zugänglicher Unterbrecher einzufügen, oder das Netzkabel muß mit einer in der Nähe des Geräts befindlichen, leicht zugänglichen Wandsteckdose verbunden werden, damit sich bei einer Funktionsstörung die Stromversorgung zum Gerät jederzeit unterbrechen läßt.

Use the specified power cord only

Use of power cords other than the specified ones may cause fire or electric shock. Do not damage the power cord A damaged power cord may cause fire or electric shock. When mounting the unit in a rack, be careful not to catch the power cord in the rails. Do not install the unit in humid or dusty locations Dust, soot, and oil particles in the ambient atmosphere may cause fire or electric shock. Install the dedicated circuit breaker or power switch This unit is not equipped with a main power switch on the front panel. Install the dedicated circuit breaker or power switch, and/or plug the power cord in the outlet. Do not block the ventilation slots If the ventilation slots are blocked, overheating inside the unit may cause fire. Observe the following points to ensure adequate ventilation. . Do not install in narrow or sealed locations. . Remove dust from the fan and air filter. Install in a stable location Installation in an unstable place may cause the unit fall, resulting in injury. Do not stack the units Do not stack two or more units on top of each other. Mount in a rack to avoid the risk of the unit sliding and causing injury. Ground the unit safely Failure to ground the unit may cause electric shock. Handling the unit with the handgrip Handling the unit without the handgrip may cause the unit fall off, resulting in injury. Carry the unit with more than two persons The total weight of this unit is 50 kg. Carrying the unit with less than two persons may cause injury. Mount with more than two persons The total weight of this unit is 50 kg. Mounting the unit with less than two persons may cause injury. Mount only with the specified support angles Support angles other than those specified for this unit may not be strong enough to support the unit, risking possible collapse and injury. Secure the unit to a rack with the screws If the unit is not secured completely, this may cause the unit fall off, resulting in injury. Be sure to secure the unit with the screws when mounting to the rack. (Refer to “1-5 Rack Mounting”)

Table of Contents

Manual Structure Purpose of this manual ........................................................................................ 3 (E) Related manuals................................................................................................... 3 (E) Contents ............................................................................................................... 3 (E) Trademark............................................................................................................ 3 (E) 1. Installation 1-1. Installation Procedure............................................................................1-1 (E) 1-2. Operating Conditions and Installation Space ........................................1-2 (E) 1-3. Power Supply ........................................................................................1-4 (E) 1-3-1. Information for Power Supply .............................................1-4 (E) 1-3-2. Recommended Power Cord..................................................1-4 (E) 1-4. Installation of Option Boards ................................................................1-5 (E) 1-4-1. Installation of BKMA-2010 .................................................1-5 (E) 1-5. Rack Mounting ......................................................................................1-7 (E) 1-6. Signal Input and Output ........................................................................1-9 (E) 1-7. Connecting Connectors and Cables ....................................................1-10 (E) 1-8. Connection ..........................................................................................1-11 (E) 1-9. Checks after Connection .....................................................................1-13 (E) 1-9-1. Checking MAV-2000 .........................................................1-13 (E) 1-9-2. Checking BKMA-2010 ......................................................1-13 (E) 1-9-3. Error Display ......................................................................1-13 (E) 2. Service Overview 2-1. Cleaning the Air Filter ..........................................................................2-1 (E) 2-2. Functional Descriptions of Board Switches and LEDs .........................2-2 (E) 2-2-1. TM-37 Board........................................................................2-2 (E) 2-2-2. FM-62 Board ........................................................................2-4 (E) 2-2-3. IF-741 Board ........................................................................2-6 (E) 2-2-4. IF-742 Board ........................................................................2-7 (E) 2-2-5. DM-119 Board (BKMA-2010) ............................................2-8 (E)

Purpose of this manual

This manual is the installation manual of the MAV-2000 Multi Access Video and Audio Server. This manual is intended for use by trained system and service engineers, and describes the information regarding installation. Related manuals Besides this Installation Manual, the following manuals are available for the MAV-2000. ..... MAV-2000 Operation Manual (supplied with the MAV-2000) This manual describes the application and operation of the MAV-2000. ..... MAV-2000 Maintenance Manual (available on request) This manual describes the information that premise the service based on main parts replacement (upgrading, self-diagnostics, replacement of the parts and boards, electrical alignment, and circuit descriptions, etc.). If this manual is required, please contact your local Sony Sales Office/Service Center. Contents The following is a summary of all the section for understanding the contents of this manual. Section 1 Installation Explains the operating conditions, installation space, power supply, installation of option boards, rack mounting, connection, and checks after installation. Section 2 Service Overview Explains the cleaning procedure of the air filter, the function and factory setting of the switches and LEDs on the board. Trademark Trademarks and registered trademarks used in this manual are follows. . Ethernet is a registered trademark of Xerox Corporation. Manual Structure

The installation procedure of the MAV-2000 is shown in the following flowchart.

Refer to each item in this manual for details. This unit is supplied with the following parts. Plug Holder 3 pcs Ornamental Washer 4 pcs Screw (RK5 x 14) 4 pcs Operation Manual 1 pc Installation Manual 1 pc Start Determination of Installation Space Rack Mounting Installation of Option Boards Connection Initial Settings Checks after Connection End 1-2. Operating Conditions and Installation Space 1-3. Power Supply 1-5. Rack Mounting 1-4. Installation of Option Boards 1-6. Signal Input and Output 1-7. Connecting Connectors and Cables 1-8. Connection Initial Settings Using Supplied Software System Phase Adjustment (BKMA-2010) 1-9. Checks after Connection To be published soon

Operating Conditions and Installation Space

Operating Conditions Operating temperature +5 dC to +40 dC Performance humidity 20 % to 90 % (No condensation) Mass MAV-2000 : Approx. 41 kg BKMA-2010 : Approx. 2.4 kg (per one set) To prevent overheating of the MAV-2000 ensure that there is good air circulation around the unit. w Do not install the unit in humid or dusty environment. c Do not stack the units. 1-2. Operating Conditions and Installation Space

Do not block ventilation.

Both of the front and rear sides must be at least 30 cm away and both sides must be at least 20 cm away from the walls for ventilation and maintenance. Do not stop the fan or block the ventilatior because this unit is air-cooled by the fan on the side view of the unit and the power supply. If not, a fire or failure may occur. 1-2. Operating Conditions and Installation Space 482 650 37.5 37.5 19.1 13.6 187.5 166.9 354.4 (8U) 279.4 661 667 465 424 387 498 67 55 161.7 141 141 105.3 47 27 Unit : mm

1-3. Power Supply

1-3. Power Supply 1-3-1. Information for Power Supply Power voltage : 100 to 240 V AC Power frequency : 50/60 Hz Power consumption : Max. 800 W Current consumption : 8 A (at maximum load)/120 V 3.4 A (at maximum load)/240 V Rush Current : 120 V IN : 49 A (0-peak) 240 V IN : 34 A (0-peak) w This unit has no power switch on the front panel. When installing the unit, incorporate a readily accessible disconnect device in the fixed wiring, or connect the power cord to a socket-outlet which must be provided near the unit and easily accessible, so that the user can turn off the power in case a fault should occur. 1-3-2. Recommended Power Cord For customers in the U.S.A. and Canada. Required Part 1 Power Cord, 125 V 13 A (2.5 m) : !1-558-527-11 2 Plug Holder : 3-613-640-01 (Supplied Accessory) For customers in the United Europe. Required Part 1 Power Cord, 250 V 10 A (2.5 m) : ! 1-782-929-11 2 Plug Holder : 3-613-640-01 (Supplied Accessory) w . Use the specified power cord only. . Do not damage the power cord. c . Ground the unit safely. . For a distributor box in the electrical system, use appropriate one with enough capacity for the rush curent mensioned above. Connect the power cord to the outlet directly without using an extension cord. n For the customers outside the area as shown above. Please consult with local Sony’s sales/service office. 1 2 AC inlet (MAV) 1 2 AC inlet (MAV) Safety earth (Green/Yellow) Live (Brown) Neutral (Blue)

1-4. Installation of Option Boards

1-4. Installation of Option Boards 1-4-1. Installation of BKMA-2010 General Information for Installation . When you want to install the BKMA-2010, install it into the slot (such as slot 1, slot 1X, slot 1Y or the like) that correctly corresponds the front and rear of the MAV-2000. (Refer to the inscription on the front and rear panel indication.) Also, install the BKMA-2010 starting from the topmost slot in this order. . Do not open the slots to maintain the cooling effect of this unit. Be sure to attach blank panels to vacant slots. . There are no adjustments to be made after installing the board. Installation Procedure 1. Turn off the main power of this unit. 2. Remove the sixteen fixing screws from the blank panels and remove all the blank panels 2U/4U. n Keep the removed blank panel. 3. Insert the BKMA-2010 (DPR board) into the slot and push in the handles on the board in the direction of the arrow to connect the board to the mother board completely. .� .� .� .� .� . MAV-2000 (rear side) 1X slot 1Y slot 6X slot 6Y slot BVTT3 x 6 BVTT3 x 6 BVTT3 x 6 BVTT 3 x 6 Blank panels 4U Blank panels 2U Handle Handle DPR board Rear side Option slot Front side Option slot 1X 1Y 2X 2Y 6X 6Y 1 2 6 IF IN IF OUT TM FM .......... .......... ............ ............ MAV-2000 (side view)

1-4. Installation of Option Boards

4. Fix the BKMA-2010 using the two screws that were securing the blank panel and the supplied two screws. 5. Attach the BKMA-2010 (DPR board) in the same way. 6. Change the combination of the blank panels so that all slots are not released. 7. Fully loosen the three screws (with drop-safe) and open the front panel. 8. Remove the eight screws (PSW3 x 6) and remove the board fixing plate. BVTT3 x 6 BVTT3 x 6 Blank panels 4U Blank panel 2U RK4 x 16 PSW3 x 6 Front panel Board fixing plate 9. Insert the BKMA-2010 (DM board) into the slot. Push in the board in the direction of the arrow to connect it to the mother board completely. 10. After connecting the board, push the levers in the direction of the arrow to lock them. 11. Attach the board fixing plate. 12. Unlock the stopper on the front panel, close the front panel, and tighten the three screws (with drop-safe). Lever Lever DM board Stopper Stopper

Install the unit in a stable location.

If the unit is mounted on a unstable table or slant bench, the unit can fall and result in physical injury. c Use the specified support angle. If the parts other than the specified one are used, the unit can fall and results in physical injury. This unit can be mounted in a 19-inch standard rack of EIA standard. To mount the unit in the rack use the specified support angle kits and parts. n Mount the unit in the rack with the HDD removed from the unit. Specified rack mount kit : RMM-2000 (option) Constituent parts . Outer Support Assembly 2 pcs Outer Support 2 pcs Bracket 4 pcs Screw (B4 x 12) 8 pcs Inner Support 2 pcs . Plate Nut 4 pcs . Screw (B4 x 12) 16 pcs The following parts are supplied for rack mounting. . Screw (RK5 x 14) 4 pcs . Ornamental Washer 4 pcs n Standard Tightening Torque Screw Size Standard Tightening Torque M3.0 0.7 to 1.0 N.m (7 to 10 kgf.cm) M4.0 1.2 to 1.6 N.m (12 to 16 kgf.cm) 1-5. Rack Mounting 1. If there is any equipment with an HDD installed in the rack and the main power on, turn off the main power. 2. Remove the four screws from the side of the unit, lift up the unit and remove the four foot holder assemblies. 3. Remove the 10 screws on the side of the unit and attach the inner support to the side of the unit using the removed screws. B4 x 8 Foot holder assembly B4 x 8 B4 x 8 Inner supports

Tighten completely all the screws loosened in step 4

and tightened temporarily in step 5. 7. Install the unit into the rack in such a manner that the inner support comes on top of the outer support of the rack. c Be sure to mount the equipment in the rack with two persons or more. If only one person mounts the equipment in the rack, backache or injury may result and the equipment may fall. 1-5. Rack Mounting 4. Loosen the four screws of the outer support assembly to slide the bracket. 5. Attach the outer support assembly to the rack tempo- rarily. B4 x 12 B4 x 12 Bracket Bracket Outer support assembly B4 x 12 12.7 12.7 31.75 Outer support Nut plate Bracket Rack side The projected side should face up. Unit : mm Outer support Bracket Inner support Rack side Main unit

After installing the rack into the unit, fix the rack angle

on the rack using the supplied ornament washers and the screws. c Tighten the screws of the rack angle completely. If the screws are not tightened, the unit may slip from the rack and fall, causing injury. 1-5. Rack Mounting 1-6. Signal Input and Output 1-6. Signal Input and Output The input and output signals of each connector on the connector panel are as follows: ETHER : 10BASE-T (8-pin Modular jack) Pin No. Signal 1 TX + 2 TX _ 3 RX + 4-5 _ 6 RX _ 7-8 _ REMOTE : RS-422A (D-sub 9-pin, Female) Pin No. Signal 1 GROUND 2 OPERATE 3 WARNING 4 ERROR 5 _ 6 _ 7 _ 8 _ 9 GROUND RK5 x 14 RK5 x 14 Ornament washers 1 8 5 1 6 9

1-7. Connecting Connectors and Cables

1-7. Connecting Connectors and Cables When connecting cables to various connectors on the rear panel at the time of installing or servicing, connect the following connectors/cable or their equivalents. Connector of the MAV-2000 Side Matching Connector and Recommended Cable Print on Panel Connector Type Connector/Cable Type Sony Part Number TC IN BNC BNC 1-508-083-11 AUDIO IN BNC 75 Z BNC 75 Z 1-569-370-12 AUDIO OUT SDI IN BNC 75 Z BNC 75 Z 1-569-370-12 SDI OUT BELDEN 8281 cable *1) SBX BNC 75 Z BNC 75 Z 1-569-370-12 IN BELDEN 8281 cable *2) OUT REF. VIDEO BNC 75 Z BNC 75 Z 1-569-370-12 VS-BUS BELDEN 8281 cable *1) STATUS OUT D-sub 9-pin, female D-sub 9-pin, male 1-560-651-00 (Connector) RCC-5G, 10G, 30G (cables)*3) 1-561-749-00 (Shell) ETHER-1, 2 (10Base-T) RJ45 UTP (Unshielded twisted-pair) cable REMOTE D-sub 9-pin, female D-sub 9-pin, male 1-560-651-00 (Connector) RCC-5G, 10G, 30G (cables)*3) 1-561-749-00 (Shell) *1) : BELDEN 8281 cable (Max. 200 m) or the equivalent. *2) : BELDEN 8281 cable (Max. 20 m) or the equivalent. *3) : These cables are available as optional accessories. The length of the cables are 5 m, 10 m and 30 m respectively.

Connect the MAV-2000 to the hard disk drive array units (abbreviates to RAID) MAV-S2000 as shown here:

n The rotary switch and the piano switch of MAV-S2000 are located behind the cover shown in Fig. 1. Remove the screw and the cover before switching them. Connection to the MAV-S2000 (single mode) ID SET UP HDD array unit (1) MAV-S2000 HDD array unit (2) MAV-S2000 1 4 Fig. 1 Cover B3 x 6 Rotary SW Set the first switch to the “1” position. 1 SBX OUT 1 SBX IN 1 SBX IN 1 SBX OUT 1 SBX IN 1 BNC cable BNC cable BNC cable BNC cable SBX IN2 SBX OUT1 SBX OUT2 Multi access video/audio server MAV-2000 4bit piano switch .Single mode : bit 1 DOWN .Terminal : bit 4 DOWN 1 4 4bit piano switch .Single mode : bit 1 DOWN .Terminal : bit 4 DOWN Rotary SW Set the first switch to the “1” position. 1

Connection to the MAV-S2000 (dual mode)

ID SET UP HDD array unit (1) MAV-S2000 HDD array unit (2) MAV-S2000 1 4 Fig. 1 Cover B3 x 6 1 4 1 BNC cable BNC cable BNC cable Multi access video/audio server MAV-2000 SBX IN4 SBX IN3 SBX IN2 SBX IN1 SBX OUT4 SBX OUT2 SBX OUT1 SBX IN2 SBX IN1 SBX OUT2 SBX OUT1 SBX IN2 SBX IN1 SBX OUT1 SBX OUT2 SBX OUT3 Rotary SW Set the first switch to the “1” position. 1 Rotary SW Set the first switch to the “1” position. 4bit piano switch .Dual mode : bit 1 UP .Center : bit 4 DOWN 4bit piano switch .Dual mode : bit 1 UP .Terminal : bit 4 DOWN

1-9. Checks after Connection

1-9. Checks after Connection After installing the unit, check to see the lighting operation of the following LEDs to determine whether the system is get up and running normally or not. n Ensure that the unit is under the following conditions before checking of the LEDs’ operation. . The RAIDs connected to the MAV-S2000 are get up and running. . The REF VIDEO connector of the MAV-2000 receives a signal with a connected cable. 1-9-1. Checking MAV-2000 7-seg LEDs’ Operation Board Ref.No. (Address) Type Color Operation TM-37 ND201 (L-5) 7-seg LED _ Outer segments flash cyclically FM-62 ND401 (A-7) 7-seg LED _ Outer segments flash cyclically Front Panel Indicators’ Operation Status Indicator Color Operation POWER A green Turns on POWER B green Turns on POWER C green Turns on BUSY Amber Flashes or turns off SYSTEM green Turns on 1-9-2. Checking of BKMA-2010 LEDs’ Operation Board Ref.No. (Address) Type Color Operation DM-119 ND401 (L-5), ND402 (L-6) 7-seg LED _ All segments of the 7-segment LED on the left flash cyclically 1-9-3. Error Display The 7-segment displays of the TM-37 board, FM-62 board and DM-119 board remain at “E1” during startup, and errors will be detected by the self-diagnostics of each board. Clear the error referring to the Maintenance Manual, Section “2-4. Error Messages”.

RK4 x 16

Filter (B) Filter (A) Stopper Stopper 2-1. Cleaning the Air Filter A filter is fitted on the rear side of the front panel assembly of the unit. If accumulated dust on the filter impedes the flow of air, the inside may heat up and troubles may occur. Clean the filter periodically. Cleaning 1. Turn off the main power of the MAV-2000. 2. Fully loosen the three screws (with drop-safe). 3. Open the front panel assembly in the direction of the arrow. 4. Press the stopper in the direction of the arrow to lock the front panel. 5. Remove the filter (A) and filter (B). 6. Remove the dust from the filter using a vacuum. 7. Attach the filter in reverse order of the disassembly procedure. 8. Unlcok the stopper and close the front panel.

Functional Descriptions of Board Switches and LEDs

2-2-1. TM-37 Board (Side A/component side) Switches n Do not change the setting of the “Factory use” switches. Ref. No. Address Name Function Factory setting S201 (L-7) Abort switch For debug _ S202 (L-7) Reset switch Initializes the TM-37 board _ S203 (L-6) Test switch Factory use 2-2. Functional Descriptions of Board Switches and LEDs A B C D E F G H J K L 1 2 3 5 4 6 7 8 9 S201 S202 S203 ND201 D201 D202 D203 D204 D205 D206 D207 D208 D703 D702 D701 OPEN 1 2 3 4 5 6 7 8

2-2. Functional Descriptions of Board Switches and LEDs

LEDs Ref. No. Address Indication color Name Function Normal state D201 (L-5) Green _ Turns on with REF LOCK _ D202 (L-5) Green _ Turns on when REF video is input _ D203 (L-5) Green _ Turns on during interrupt of the dual port RAM Turns off D204 (L-6) Green _ Not used Turns off D205 (L-6) Green _ Time Slot (LSB) Flashes D206 (L-6) Green _ Time Slot Flashes D207 (L-6) Green _ Time Slot Turns off D208 (L-6) Green _ Time Slot (MSB) Turns off D701 (L-3) Green _ Turns on when Ether is used for test Turns off D702 (L-3) Green _ Turns on when Ether is used for test Turns off D703 (L-2) Red _ Turns on when Ether is used for test Turns off ND201 (L-5) _ _ Flashes clockwise during normal run Flashes

2-2. Functional Descriptions of Board Switches and LEDs

2-2-2. FM-62 Board (Side A/component side) Switches n Do not change the setting of the “Factory use” switches. Ref. No. Address Name Function Factory setting S401 (A-3) Abort switch For debug _ S402 (A-9) All reset switch Initializes the MAV-2000 _ S403 (A-3) Reset switch Initializes the FM-62 board _ S404 (A-4) Test switch Factory use S401 S403 S404 ND401 S402 3 2 1 A B C D E F G H J 7 6 5 4 8 9 10 D401 D402 D403 D404 D405 D406 D407 D408 OPEN 1 2 3 4 5 6 7 8

Shows the state of SBX SDRAM

D402 (A-6) Green _ D403 (A-6) Green _ Turns on during interrupt of the dual port RAM Turns off D404 (A-6) Green _ Flashes when battery (BT1001) runs out Turns off D405 (A-5) Green _ Turns on when SBX gate is open Turns off D406 (A-5) Green _ Not used Turns off D407 (A-5) Green _ Not used Turns off D408 (A-5) Green _ Time Slot (LSB) Flashes ND401 (A-7) _ _ Flashes clockwise during normal run Flashes D401 D402 Turns off Turns off : CPU mode Turns on Turns off : Status Sense mode Turns off Turns on : Get mode Turns on Turns on : Put mode 2-2. Functional Descriptions of Board Switches and LEDs

2-2-3. IF-741 Board

(Side A/component side) Switches n n n n n Do not change the setting of the “Factory use” switches. Ref. No. Address Name Function Factory setting S801 (J-11) Test switch Factory use LEDs Ref. No. Address Indication color Name Function Normal state D502 (K-11) Green CH1 Turns on when SBX SYNC is detected Turns off D503 (K-11) Green CH3 D504 (K-12) Green CH5 D505 (K-12) Green CH7 D506 (K-11) Green CH2 D507 (K-11) Green CH4 D508 (K-12) Green CH6 D509 (K-12) Green CH8 2-2. Functional Descriptions of Board Switches and LEDs A B C D E F G H J K L M 1 2 3 4 5 6 7 8 9 10 11 12 S801 D502 D506 D503 D507 D504 D508 D505 D509 ON 1 2 3 4 5 6 7 8

2-2. Functional Descriptions of Board Switches and LEDs

2-2-4. IF-742 Board (Side A/component side) Switches n n n n n Do not change the setting of the “Factory use” switches. Ref. No. Address Name Function Factory setting S801 (F-12) Test switch Factory use S802 (E-11) PLL ADJ Enters the PLL ADJ mode Mode switch S802-1, 2: Turns on simultaneously LEDs Ref. No. Address Indication color Name Function Normal state D202 (G-11) Green CH1 Turns on when BINGO SLOT is “E” Turns off D203 (G-12) Green CH3 D204 (G-12) Green CH5 D205 (G-12) Green CH7 D206 (G-12) Green CH2 D207 (G-12) Green CH4 D208 (G-12) Green CH6 D209 (G-12) Green CH8 A B C D E F G H J K L M S801 S802 D202 D206 D203 D207 D204 D208 D205 D209 1 2 3 4 5 6 7 8 9 10 11 12 ON 1 2 3 4 5 6 7 8 ON 1 2

2-2. Functional Descriptions of Board Switches and LEDs

2-2-5. DM-119 Board (BKMA-2010) (Side A/component side) Switches n Do not change the setting of the “Factory use” switches. Ref. No. Address Name Function Factory setting S401 (L-8) Abort switch For debug _ S402 (L-7) Reset switch Initializes the DM-119 board _ S403 (L-7) Test switch Factory use A B C D E F G H J K L ND401 D801 D802 D803 ND402 S403 S401 S402 1 2 3 4 5 6 7 8 9 D1001 D1002 D1003 D1004 D1005 D1006 D1007 D1008 D1009 OPEN 1 2 3 4 5 6 7 8

2-2. Functional Descriptions of Board Switches and LEDs

LEDs Ref. No. Address Indication color Name Function Normal state D801 (L-2) Green _ Turns on when Ether is used for test Turns off D802 (L-2) Green _ D803 (L-1) Red _ D1001 (L-9) Green _ Flashes when PLD runs normally Flashes D1002 (L-8) Green _ D1002 : Turns on by reset Flashes D1003 (L-8) Green _ D1003 : Turns on during interrupt of the dual port RAM Flashes D1004 (L-8) Green _ Ch#X BingoTomeslot display Flashes during recording or playback of Ch#X port Turns off while Ch#X port is waiting D1005 (L-8) Green _ Ch#Y BingoTomeslot display Flashes during recording or playback of Ch#Y port Turns off while Ch#Y port is waiting D1006 (L-8) Green _ Ch#X SBX Memory Write display Turns on when Ch#X port is recording Flashes when Ch#X port is in playback Turns off while Ch#X port is waiting D1007 (L-8) Green _ Ch#X SBX Memory Read display Turns on when Ch#X port is recording Flashes when Ch#X port is in playback Turns off while Ch#X port is waiting D1008 (L-8) Green _ Ch#Y SBX Memory Write display Turns on when Ch#Y port is recording Flashes when Ch#Y port is in playback Turns off while Ch#Y port is waiting D1009 (L-8) Green _ Ch#Y SBX Memory Read display Turns on when Ch#Y port is recording Flashes when Ch#Y port is in playback Turns off while Ch#Y port is waiting ND401 (L-5) _ _ Rotates during normal operation (left half) (7-seg) ND402 (L-6) _ _ Rotates during normal operation (left half) (7-seg)

The material contained in this manual consists of

information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation. Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l’équipement à moins d’une permission écrite de Sony Corporation. Das in dieser Anleitung enthaltene Material besteht aus Informationen, die Eigentum der Sony Corporation sind. Die Sony Corporation untersagt ausdrücklich die Vervielfältigung jeglicher Teile dieser Anleitung oder den Gebrauch derselben für irgendeinen anderen Zweck als die Bedienung oder Wartung der in dieser Anleitung beschriebenen Ausrüstung ohne ausdrückliche schriftliche Erlaubnis der Sony Corporation.