TABLE OF CONTENTS Copyright, Trademarks, Legal Disclaimers ....................................................................3 Introduction .......................................................................................................................4 Supported Provisioning Methods ........................................................................................4 DHCP .................................................................................................................................................................... 4 Manually Setting the Setting Server .............................................................................................................. 5 PNP ....................................................................................................................................................................... 6 Snom Redirection Service ............................................................................................................................... 6 User Agent .........................................................................................................................7 Settings and Configuration ..............................................................................................8 Viewing, Saving, and Loading Settings ...............................................................................8 Comprehensive List of Settings ...........................................................................................9 Global Settings ................................................................................................................................................... 9 Server Settings ................................................................................................................................................20 Extension Settings ...........................................................................................................................................23 Repeater Settings ............................................................................................................................................27 Multicell Settings .............................................................................................................................................29 Emergency Settings ........................................................................................................................................31 Device Type Settings .......................................................................................................................................32 Firmware Settings ...........................................................................................................................................34 Phonebook Settings ........................................................................................................................................35 File Settings ......................................................................................................................................................35 Examples for Configuration Files ......................................................................................36 Basic Configuration 1 - 1 base station, 1 handset .....................................................................................37 Basic Configuration 2 - 1 base station, 3 handsets ...................................................................................38 Basic Configuration 3 - 1 base station, 1 handset, 2 lines with different access codes ....................39 Basic Configuration 4 - 1 base station, 1 handset, phonebook in settings file ....................................40 Basic Configuration 5 - Provisioning Firmware and Phonebook Settings ...........................................41 Main Provisioning Configuration file .......................................................................................................41 firmware.xml ...............................................................................................................................................41 Snom_phonebook.xml ...............................................................................................................................41 Snom_settings.xml .....................................................................................................................................42 Basic Configuration 6 - Multicell ...................................................................................................................43 Multicell Settings for Primary Base Station and Secondary Base Stations ..................................43 Primary Base Station Settings .................................................................................................................43

Provisioning Guide M900, M700, M300

Copyright, Trademarks, Legal Disclaimers Copyright, Trademarks, Legal Disclaimers © 2019 Snom Technology GmbH. All Rights Reserved. Snom , the names of Snom products, and Snom logos are trademarks owned by Snom Technology GmbH. All other product names and names of enterprises are the property of their respective owners. Product specifications are subject to change without notice. Snom Technology GmbH reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact. Texts, images, and illustrations and their arrangement in this document are subject to the protection of copyrights and other legal rights worldwide. Their use, reproduction, and transmittal to third parties without express written permission may result in legal proceedings in the criminal courts as well as civil courts. When this document is made available on Snom’s web page, Snom Technology GmbH gives its permission to download and print copies of its content for the intended purpose of using it as a manual. No parts of this document may be altered, modified or used for commercial purposes without the express written consent of Snom Technology GmbH. Although due care has been taken in the compilation and presentation of the information in this document, the data upon which it is based may have changed in the meantime. Snom therefore disclaims all warranties and liability for the accurateness, completeness, and currentness of the information published, except in the case of intention or gross negligence on the part of Snom or where liability arises due to binding legal provisions. Change Log Release Date Description v1.01 October 31, 2019 Initial Release

Provisioning Guide M900, M700, M300

Introduction Introduction This configuration manual covers the initial setup of M300, M700, and M900 bases for administrators who want to remotely configure and deploy the Snom DECT solution. This guide applies to firmware 4.50 and higher. The base stations share most of their settings and provisioning capabilities with Snom desktop phones. However, due to the different nature of the M-series products, there are certain settings that either do not exist or are configured differently on Snom desktop phones. Note: The M300 base station is sold as part of the M325 Bundle. Supported Provisioning Methods • DHCP (Option 43, 66, 67, 120) • Manual Setting of Setting Server • PnP • Snom Redirection Service DHCP The DHCP server must be configured with additional DHCP options containing the URL of the provisioning server that are provided to the DECT base stations when they are booting. The base stations will then request their configuration parameters from the provisioning server which will result in a "ready-to-use" phone setup without manual configuration. For more information, see https://www.snom.com/auto_provisioning_dhcp_options. Currently the base stations support the following DHCP options: Option Description Example for Valid Values Comments 43 Vendor-specific information For examples and a detailed explanation, see https://www.snom. com/auto_provisioning_dhcp_ options/ This option is used by clients and servers to exchange vendor- specific information. 66 TFTP server name http://provisioning.company.com This option is used to identify a TFTP server. The supported protocols are http, https and tftp. 67 Bootfile name directory/snomsettings.xml This option is used to identify a bootfile. 120 SIP server 00:04:63:73:31:35:04:73:6e:6f:6d:03 :63:6f:6d:00 (cs15.snom.com) This option is used to define a SIP server. Do not use this option when you are already configuring your sip server in the config file. This will lead to conflicts in the settings.

Provisioning Guide M900, M700, M300

Introduction Manually Setting the Setting Server A very basic way of configuring the Provisioning Server for the base stations is by entering the configuration server address and the name of the file in the management settings of the base‘s web interface. Every time the base station boots, it will request its configuration parameters from the provisioning server, resulting in a "ready-to-use" phone setup without having to configure it manually.

Provisioning Guide M900, M700, M300

Introduction PNP Plug & Play (PnP) provides a proprietary method to enable provisioning on M300, M700, and M900 DECT base stations. By default the base stations send SIP SUBSCRIBES messages to a multicast address. Any SIP server that understands the message may reply with a SIP NOTIFY message containing the URL of the provisioning server from where the phones can request their configuration. An example SIP SUBSCRIBE message from the base station would look like this: SUBSCRIBE sip:MAC%3a0004136*****@224.0.1.75 SIP/2.0 Via: SIP/2.0/UDP 10.0.0.90:5060;branch=z9hG4bKl1d23iyadenuaa1jr4vm Max-Forwards: 70 From: ;tag=dmrud.mzfyg66 To: Call-ID: [email protected] CSeq: 20264 SUBSCRIBE Contact: Accept: application/url Allow: INVITE, CANCEL, BYE, ACK, REGISTER, OPTIONS, REFER, SUBSCRIBE, NOTIFY, MESSAGE, INFO, PRACK, UPDATE Allow-Events: dialog,message-summary Event: ua-profile;profile-type=“device“;vendor=“Snom “;model=“Snom M900“;version=“04.50.0005“ Expires: 0 Supported: replaces,100rel User-Agent: Snom M900/04.50.0005 (MAC=0004136*****; SER= 00000; HW=255) Content-Length: 0 If any SIP application within one-hop range understands this message, a SIP 200 OK confirmation is sent, followed by a SIP NOTIFY message containing the provisioning URL. The base station accepts this message and confirms it with a SIP 200 OK. Snom Redirection Service Snom's Secure Redirection and Provisioning Service (SRAPS) allows customers to register/list/ unregister the MAC addresses of their M900, M700, and M300 DECT base stations on Snom 's provisioning server and assign a redirection URL pointing to their own provisioning server. The service is designed to implement an easy-to-use interface (XMLRPC) for interaction with remote client applications. The communication between server and remote client application is secure. A detailed explanation can be found here: https://www.snom.com/sraps/.

Provisioning Guide M900, M700, M300

User Agent User Agent The devices follow Snom ‘s user agent scheme for HTTP and SIP communication. Two examples for GETs: Mozilla/69.0 (compatible; Snom M900 4.50.0005 0004136*****) Mozilla/69.0 (compatible; Snom M700 4.50.0005 0004136*****) Mozilla/69.0 (compatible; Snom M300 4.50.0005 0004136*****) • "Snom M900", "Snom M700" and "Snom M300" identify the type of device. • "4.50.0005" defines the software version. The first part ("4") describes the major release), the second part ("50") the version, and the last part ("0005") the specific build number. • Following the software version is the MAC address of the base station, in this case "0004136*****".

Provisioning Guide M900, M700, M300

Settings and Configuration Settings and Configuration Viewing, Saving, and Loading Settings You can view and save your current settings and load a settings file on the Configuration page of the base station's web interface. The comprehensive list of settings available for M series base stations is provided on the following pages: Global Settings ............................. page 9 Server Settings ............................ page 20 Extension Settings ...................... page 22 Repeater Settings ....................... page 26 Multicell Settings ......................... page 29 Firmware Settings ...................... page 30 Phonebook Settings .................... page 35 File Settings .................................. page 35

Provisioning Guide M900, M700, M300

Settings and Configuration Comprehensive List of Settings Global Settings Global Settings Setting Valid value(s) Description allow_call_groups on / off M300 only. The setting controls whether local call groups within the base station are enabled or not. Once a handset has been registered on the base station, the setting cannot be changed. Default value: on ac_code e.g. 1234 Defines the 4-digit code for a handset to connect to and register with the selected base station. Changing the code for a handset that is already registered will have no effect. Default Value: 0000 country_region_id tone_scheme = US 0 = Alabama 1 = Alaska 2 = Arizona 3 = Arkansas 4 = California 5 = Colorado 6 = Connecticut 7 = Delaware 8 = Florida 9 = Georgia 10 = Hawai 11 = Idaho PST 12 = Idaho MST 13 = Illinois 14 = Indiana 15 = Iowa 16 = Kansas 17 = Kentucky EST 18 = Kentucky CST 19 = Louisiana 20 = Maine 21 = Maryland 22 = Massachusetts 23 = Michigan 24 = Minnesota 25 = Mississippi 26 = Missouri 27 = Montana 28 = Nebraska 29 = Nevada If a country has regions/states ( e.g. the US or Australia), this setting allows their configuration. If not, the setting will not be used. Default Value: Important: This setting is related to the timezone and tone_scheme settings and has to be set accordingly for them to work correctly. Note: In addition to the AC, the handset has a PIN for deregistering it from the base, performing factory resets, etc. The default value of the PIN is also 0000; it can only be changed on the handset itself. The PIN cannot be set or altered from the base station, whether by provisioning or via the web user interface.

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description 30 = New Hampshire 31 = New Jersey 32 = New Mexico 33 = New York 34 = North Carolina 35 = North Dakota 36 = Ohio 37 = Oklahoma 38 = Oregon 39 = Pennsylvania 40 = Rhode Island 40 = Rhode Island 41 = South Carolina 42 = South Dakota CST 43 = South DakotaMST 44 = Tennessee 45 = Texas 46 = Utah 47 = Vermont 48 = Virginia 49 = Washington 50 = West Virginia 51 = Wisconsin 52 = Wyoming tone_scheme GER, FRA, ITA, NLD,SWE, ESP, DNK, SWI, AUT, GBR, NOR, USA, AUS, CHN, IND, JPNMEX, NZL This setting is used to generate special tones in the handset, e.g., the country-specific ringtone and busy tones. Default Value: USA Important: This setting is related to the timezone and country_region_id and has to be set accordingly for them to work correctly. dialplan_enabled off / on Specifies whether the configured dial plan is enabled or not. Default Value: off dialplan_maxlength e.g. 6 Specifies the maximum length of a number up to which no dialplan_prefix will be added. Default Value: 0 dialplan_prefix e.g. 030 Specifies the prefix that is added when the dialed number is longer than dialplan_maxlength. Default Value: dst_by_country_region off / on Sets the DST by country/region. Default Value: on dst_enable off / on / auto Specifies whether or not to apply DST changes to display time. Default Value: auto dst_fixed_day_enable off = Use month and date on = Use month and day of week Specifies whether or not to use a fixed day of the week when applying DST changes. Default Value: on dst_start_date 1-31 Specifies the day of the month on which DST begins. Default Value: 0

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description dst_start_day_of_week 1 = Sunday 2 = Monday; 3 = Tuesday 4 = Wednesday 5 = Thursday; 6 = Friday 7 = Saturday Specifies the day of the week on which DST begins. Default Value: 1 dst_start_month 1-12 Specifies the month in which DST begins. Default Value: 3 dst_start_time 0-23 Specifies the time when DST begins. Default Value: 2 dst_start_wday_last_in_ month 1 = First in month 2 = Second in month 3 = Third in month 4 = Second to last in month 5 = Last in month Specifies on which dst_start_day_of_week in the month DST begins. * Default Value: 2 * For example, if DST begins at 2 a.m. on the last Sunday in March, the settings are: dst_start_month: 3 dst_start_time: 2 dst_start_day_of_week: 1 dst_start_wday_last_in_month: 5 dst_stop_month 1-12 Specifies the month in which DST ends. Default Value: 11 dst_stop_date 1-31 Specifies the day of the month on which DST ends. Default Value: 0 dst_stop_time 0-23 Specifies the time when DST ends. Default Value: 2 dst_stop_day_of_week 1 = Sunday 2 = Monday 3 = Tuesday 4 = Wednesday 5 = Thursday 6 = Friday 7 = Saturday Specifies the day of the week on which DST ends. Default Value: 1 dst_stop_wday_last_in_ month 1 = First in month 2 = Second in month 3 = Third in month 4 = Second to last in month 5 = Last in month Specifies on which dst_stop_day_of_week in the month DST ends. Default Value: * For example, if DST ends at 2 a.m. on the last Sunday in October, the settings are: dst_stop_month: 10 dst_stop_time: 2 dst_stop_day_of_week: 1 dst_stop_wday_last_in_month: 5

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description timezone USA-10, USA-9, CAN-8 MEX-8, USA-8, CAN-7 MEX- 7, USA2-7, USA-7 CAN-6, CHL-6, MEX-6 USA-6, BHS- 5, CAN-5 CUB-5, USA-5, VEN-4.5 CAN-4, CHL-4, PRY-4 BMU-4, FLK-4, TTB-4 CAN-3.5, GRL-3, ARG-3 BRA2-3,BRA1-3,BRA-2 PRT-1, FRO-0, IRL-0 PRT-0, ESP-0, GBR-0 ALB+1, AUT+1, BEL+1 CAI+1, CHA+1, HRV+1 CZE+1, DNK+1, FRA+1 GER+1, HUN+1, ITA+1 LUX+1, MAK+1, NLD+1 NAM+1, NOR+1, POL+1 SVK+1, ESP+1, SWE+1 CHE+1, GIB+1, YUG+1 WAT+1, BLR+2, BGR+2 CYP+2, CAT+2, EGY+2 EST+2, FIN+2, GAZ+2 GRC+2, ISR+2, JOR+2 LVA+2, LBN+2, MDA+2 RUS+2, ROU+2, SYR+2 TUR+2, UKR+2, EAT+3 IRQ+3, RUS+3, IRN+3.5 ARM+4, AZE+4, GEO+4 KAZ+4, RUS+4, KAZ+5 KGZ+5, PAK+5, RUS+5 IND+5.5, KAZ+6,RUS+6 RUS+7, THA+7, CHN+7 SGP+8, KOR+8, AUS+8 JPN+9, AUS+9.5 AUS2+9.5, AUS+10 AUS2+10, AUS3+10 RUS+10, AUS+10.5 NCL+11, NZL+12 RUS+12, NZL+12.75 TON+13 This setting is used to specify the time zone. Default Value: USA-6 tone_scheme = AUS 1 = New South Wales 2 = Victoria 3 = Tasmania 4 = Australian Capital Territory 5 = South Australia 6 = Northern Territory 7 = Queensland 8 = Western Australia web_language English, Dansk, Italiano, Türkce, Deutsch, Português, Slovenian, Dutch, Francais, Español, Russian This setting defines the language used in the web interface of the base station. Default Value: English

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description language English, Español, Deutsch, Francais, Italiano, Dutch, Português, Dansk, Svenska, Turkce, Polski, Russian, Norsk, Slovenian, Čeština, Suomi, blank (controlled by handset) This setting defines the language used on the handset. Default Value: English web_language English, Danish Italian, Türkish, German, Portuguese, Croation, Serbian, Slovenian, Dutch, French, Spanish, Russian, Polish This setting defines the language used in the web interface of the base station. Default Value: English min_jittbuf_depth 0-255 Controls the minimum jitter buffer depth. Default Value: 2 max_jittbuf_depth 0-255 Controls the maximum jitter buffer depth. Default Value: 7 number_of_base_ stations 50,127,254 The value is not freely selectable. The number of base station depends on the ratio between base stations and repeaters. Values per base station, firmware version 4.50.0005: 50/3 (i.e., 50 base stations, 3 repeaters), 127/1, 254/0 Default Value: 50 timezone_by_country_ region off / on Sets the time zone by country/region. Default Value: on auto_dect_register off / on Enable/disable the automatic DECT registration of handsets. Default Value: on tls_server_ authentication off / on Enable / disable TLS server authentication. Default Value: off eth_driver_initialize off / on Management setting indicating whether Ethernet driver is initialized if no traffic is detected for a period. Reboot is necessary when setting is changed. Default Value: off fwu_tftp_server_image_ path The path on the TFTP server in which to look for image update files. The path may contain multiple directories. The path must start with a slash and must end with a slash. Backslashes are not allowed. Default Value: text_msg_terminal_ auto_stop_allow off / on TBA Default Value: off text_msg_terminal_ auto_stop_delay 0–255 TBA Default Value: 30 text_msg_terminal_ keep_alive 1–255 This setting defines the delay in minutes before keepalive handling is triggered in the handset. Default Value: 0 ldap_username This setting specifies the bind “Username” for LDAP servers. Most LDAP servers allow anonymous binds, in which case the setting can be left blank. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description ldap_search_filter LDAP name filter is the search criteria for name look ups. The format of the search filter is compliant to the standard string representations of LDAP search filters (RFC 2254). Default Value: ldap_home_number e.g. homePhone Default Value: homePhone ldap_mobile_number e.g. mobile Default Value: mobile ldap_work_number e.g. telephoneNumber Default Value: telephoneNumber ldap_name_attributes space-separated number attributes, e.g. cn sn This setting can be used to specify the “name” attributes of each record which are to be returned by the LDAP server in the LDAP search results. The setting compresses the search results, as the server only returns the requested attributes. Please consult your system administrator on the name attributes you need to configure. Default Value: ldap_number_attributes space-separated number attributes, e.g., telephoneNumber mobile ipPhone Home This setting can be used to specify the “number” attributes of each record which are to be returned by the LDAP server in the LDAP search results. The setting compresses the search results, as the server only returns the requested attributes. Please consult your system administrator on the number attributes you need to configure. Default Value: ldap_password This setting specifies the bind “Password” for LDAP servers. This setting can be left blank in case the server allows anonymous binds. Default Value: ldap_port e.g. 389 This setting specifies the port of the LDAP server. Default Value: ldap_base e.g. ou=Snom .com - users,dc=Snom ,dc=com This setting specifies the LDAP search base (the distinguished name of the search base object) which corresponds to the location in the directory from which the LDAP search is requested to begin. Default Value: ldap_server e.g.: 1234 192.168.10.1 This setting refers to the DNS name or IP address of the LDAP server. Default Value: ldap_tls off / on This setting enables and disables use of TLS security. Default Value: off ldap_use_ext_nbr_to_ ldap_bind enabled / disabled This setting enables and disables the use of the LDAP username instead of the SIP username. Default Value: enabled ldap_virtual_lists 1 - on 0 - off This setting enables the use of virtual lists. If set to 1, virtual lists are used. If set to 0, the use of virtual lists is disabled, and the bvase will request a maximum of 50 hits. Default Value: 1

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description http_user Defines the HTTP username for your base station. Together with http_pass it will protect your web interface. Default Value: admin http_pass Defines the HTTP password for your base station. Together with http_user it will protect your web interface. Default Value: admin secure_web off / on Enables local web site HTTPS. Note: Secure web site performance is very slow. Default Value: off phone_name e.g. Snom M900 Defines the name of the base station. Default Value: Snom M900 http_client_password Sets the password to be used for the specified management_transfer_protocol. Default Value: management_transfer_ protocol 0: TFTP 1: HTTP 2: HTTPS Specifies the protocol to be used for transferring config file, FWU files, etc. Default Value: 0. management_upload_ script Specifies the script to call when uploading files using HTTP PIST. Default Value: /CfgUpload/ http_client_user Specifies the username for the specified management_transfer_protocol. If empty, the MAC address will be used as username. Default Value: mdns_support off / on Enables support for multicast DNS. Default Value: off setting_server e.g. http://www.company. com/settings/Snom _m900. xml An URL specifying the location from where to load the settings file. If the tag is read and if it is different from what’s already stored, the provisioning logic will restart, using the new value as base. The {mac} macro is supported in the URL. Default Value: network_sntp_ broadcast_enable off / on Enables reception of SNTP broadcasts from an SNTP server and thereby syncing with the received server time. Default Value: on ntp_server e.g. 10.110.21.254 Specifies the domain name or the IP address of the NTP server. Default Value: ntp_refresh_timer e.g. 3600 Specify the time in seconds after which the phone contacts the NTP server again to refresh the time. Default Value: 3600 stun_server e.g. stun.Snom .com This setting refers to the DNS name or IP address of the STUN server. Default Value: empty vlan_id e.g. 101 This setting sets the VLAN id of the base in order to connect to anything residing in a specific VLAN. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description network_vlan_ synchronization off / on When the VLAN ID in a multicell system changes, this setting determines whether the new VLAN ID is sync'd to the other bases or not. Default Value: on vlan_qos e.g. 7 This setting sets the VLAN priority of the base in order to connect to anything residing in a specific VLAN. Default Value: dhcp_option_pnp off / on Enable/disable DHCP provisioning. Default Value: on dhcp off / on This setting specifies whether DHCP is enabled or not. If it is disabled, the base will use the configured static IP address. Default Value: on dns_server1 e.g. 8.8.8.8 This setting stores the address of the primary DNS server. If DHCP is disabled, the address of the primary DNS server has to be entered here. Default Value: dns_server2 e.g. 8.8.4.4 This setting stores the address of the secondary DNS server. If DHCP is disabled, the address of the secondary DNS server has to be entered here. Default Value: gateway e.g. 10.0.0.1 This setting changes the gateway of the device. If DHCP is disabled, the gateway must be entered here. Default Value: ip_adr e.g. 192.168.1.2 This setting changes the IP address of the device. If DHCP is disabled, the IP address must be entered here. Default Value: netmask e.g. 255.255.255.0 This setting changes the netmask of the device. If DHCP is disabled, the subnet mask must be entered here.Default Value: phonebook_filename e.g. phonebook.xml Filename of the phonebook if phonebook_server_location and phonebook_location have been set. Default Value: phonebook_location http://192.168.1.2/ directory/ Specifies the location of the phonebook if phonebook_server_location = 0. Setting has to be used in conjunction with phonebook_filename. Default Value: phonebook_reload_time e.g. 10 Phonebook reload time in (s) if phonebook_server_ location = 0. Default Value: phonebook_server_ location 0 = Local 1 = LDAP 2 = XML Defines what type of phonebook is used. "Local" means the Central Directory imported onto the base station and accessible to all handsets/base stations in the installation (single cell or multicell). Default Value: 0 repeater_legacy_ support off / on This setting controls whether legacy repeaters are supported or not. Default Value: off

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description rsx_trace_internal disabled / enabled Enables downloading traces collectively from all base stations in a multicell setup Default Value: disabled rtp_collision_control off / on This setting controls whether the base station checks for RTP collision. RTP collision means that the device is receiving RTP packages from more than one source address with same SSRC. Default Value: off sip_check_sync_always_ reboot off / on Specifies whether the base station shall reboot at reception of a SIP NOTIFY with check-sync regardless of the reboot parameter being present. Values: 0: Disabled, meaning reboot=TRUE must be present to force the base station to reboot. 1: Enabled. The base station will always reboot. Default Value: off (0?) sip_conf_key_dtmf_ string This string specifies the DTMF that is sent via SIP when the conf key is pressed. Not applicable to all configurations. Default Value: pnp_config off / on Enable/disable PNP provisioning. Default Value: on enable_rport_rfc3581 off / on Enables or disables rport parameter for the Via header field. The default setting allows a client to request that the server send the response back to the source IP address and port from which the request originated. Default Value: on rtp_port_start e.g. 50004 This setting specifies the RTP start port which is used for RTP traffic. Default Value: 50004 rtp_port_end e.g. 50044 This setting specifies the RTP end port which is used for RTP traffic. Default Value: 50044 codec_tos 0-255 This option enables the phone to support quality of service (QOS) for RTP traffic in a network. Default Value: 160 sip_r_key_dtmf_string This string specifies the DTMF that is sent via SIP when the R key is pressed. Not applicable to all configurations. Default Value: network_id_port e.g. 5060 This setting specifies the SIP port which is used for SIP traffic. Default Value: 5060 signaling_tos 0-255 This option enables the phone to support quality of service (QOS) for SIP traffic in a network. Default Value: 160

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description sip_stun_bindtime_ determine off / on If STUN is enabled and sip_stun_bindtime_guard is defined, setting this to 1 forces the base station to automatically determine the duration of NAT bindings in the system. In this case, sip_stun_bindtime_guard defines the initial test duration. Default Value: on sip_stun_bindtime_ guard e.g. 80 If STUN is enabled, this value specifies in seconds how often the system will guard the NAT bindings. Default Value: 80 stun_binding_interval e.g. 90 If STUN is enabled, stun_binding_interval defines how often (in seconds) keepalive are sent in order to keep NAT bindings. If sip_stun_bindtime_determine is set, stun_binding_interval will be overruled and keep-alives will be sent with a frequency of half the determined bindtime. Default Value: 90 sip_use_different_ports off / on If this is enabled, network_id_port specifies the source SIP port used for the first instance, and all following will use succeeding ports. If disabled, the same port will be used for all accounts. Default Value: off srv_xsi_caller_id_ blocking This setting is used to enable/disable the Xsi Caller ID blocking service. Default Value: enabled log_level -1 = off 6 = normal 8 = system 7 = debug This setting defines the log level of the syslog messages that are logged. Default Value: 6 syslog_server e.g. 10.0.0.1 IP address of the syslog server. Default Value: syslog_server_port e.g. 514 Port of the syslog server. Default Value: 514 syslog_tls 0: Disabled (use UDP) 1: Enabled (use TCP with TLS) This setting defines whether the syslog connection should use secure TLS when logging. Default Value: 0 text_msg_keep_alive Integers, e.g., 30 Text Messaging Keep Alive interval (minutes). Default Value: 30 text_msg_mode 0: Disabled 1: Enabled Mode of the text messaging. Default Value: Disabled text_msg_port Integers, e.g., 1300 Port to be used with the text messaging server. Default Value: 1300 text_msg_responce_ time Integers, e.g., 30 (Note: "responce" is misspelled. Please use as is until further notice.) The text messaging response time defines the timeout for communication response in seconds. Default Value: 30 text_msg_server e.g. 192.168.10.1 Name or IP address of the text messaging & alarm server. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Global Settings Setting Valid value(s) Description text_msg_ttl Integers, e.g., 0 The Text Messaging Time To Live defines the maximum age in seconds of a jobfile. If set to 0, the function is deactivated and jobfiles do not expire. Default Value: 0 voip_sip_auto_upload off / on Enables / disables the automatic upload of SIP log files. Default Value: off web_inputs_allowed off / on If the base is configured via configuration files, this setting can be used to allow/disallow the possibility to edit the configuration directly on the web server. Default Value: on xsi_contacts_enterprise Text string The name of the phonebook. Default Value: Enterprise xsi_contacts_ enterprise_common Text string ) The name of the phonebook. Default Value: Enterprisecommon xsi_contacts_ enterprise_common_ enable on / off Enable/disable "Enterprisecommon" directory. Default Value: on xsi_contacts_ enterprise_enable on / off Enable/disable "Enterprise" directory. Default Value: on xsi_contacts_group Text string The name of the phonebook. Default Value: Group xsi_contacts_group_ common Text string The name of the phonebook. Default Value: Groupcommon xsi_contacts_group_ common_enable on / off Enable/disable "Groupcommon" directory. Default Value: on xsi_contacts_group_ enable on / off Enable/disable "Group" directory. Default Value: on xsi_contacts_personal Text string The name of the phonebook. Default Value: Personal xsi_contacts_personal_ enable off / on The name of the phonebook. Default Value: off XSI_server e.g. 192.168.10.1 The name or IP address (including path) of a server from which a XSI server can be retrieved.. Default Value: network_sip_log_server e.g. 192.168.1.2 Specifies a server to send logged SIP messages to. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Server Settings Server Settings Setting Valid Value(s) Description NOTE: Up to 10 servers with idx 1 to 10. Example: user_host idx="1" user_moh idx=1-10 Examples: <192.168.0.40> If you specify a SIP URI pointing to a media server account, the phone will, when a call is put on hold, invite this SIP URI to call the held phone to play music on hold. Default value: empty srv_att_transfer_2nd_ call_on_hold idx=1-10 off / on Specifies the attended transfer behaviour of the base. If turned on, the second call will be put on hold. If turned off, the second call is not put on hold. Default Value: on srv_broadsoft_calllog_ enable idx=1-10 off / on Enable/disable BroadWorks call log functionality for the given SIP server. Default Value: off srv_broadsoft_calllog_ server_addr idx=1-10 The address of the BroadWorks Xsi type call log server for the given SIP server.. Default Value: srv_bw_directed_call_ pickup_code idx=1-10 The access code for using BroadWorks Directed Call Pickup on the given SIP server. Default Value: srv_bw_directed_call_ pickup_enable idx=1-10 off / on Enable/disable BroadWorks Directed Call Pickup for the given SIP server. Default Value: off srv_bw_group_call_ pickup_code idx=1-10 The access code for using BroadWorks Group Call Pickup on the given SIP server. Default Value: srv_bw_group_call_ pickup_enable idx=1-10 off / on Enabl /disable BroadWorks Group Call Pickup for the given SIP server. Default Value: off srv_dtmf_payload_type idx=1-10 0-127 Set up the payload type for out-of-band DTMF here. Default Value: 101 user_dtmf_info idx=1-10 sip_info_only = SIP info off = RTP Events (RFC2833) on = SIP info and RTP Events (RFC2833 ) This setting changes depending on whether DTMF events are signaled via SIP INFO messages or via RTP events or both. Default Value: off alert_info_playback idx=1-10 off / on Enables the remote ringtone control (AlertTone) sent to the handset. Default Value: off user_srtp idx=1-10 off / on Enables/disables encryption of outgoing audio RTP streams. This setting has to be enabled if srv_srtp_auth is set to on. Likewise this has to be turned off when srv_srtp_auth is off. Default Value: off

Provisioning Guide M900, M700, M300

Settings and Configuration Server Settings Setting Valid Value(s) Description srv_sip_cli_mode idx=1- 10 0: PAI - From 1: From 2: (cid=) in Alert-Info - PAI - From This parameter defines the priority with which the base will look for CLI information in incoming SIP messages. Please note that the from header will always be used as CLI source if none of the selected header(s) is present. Default Value: 0 srv_sip_enable_blind_ transfer idx=1-10 off / on Specifies whether blind transfer is enabled or not Default Value: on timer_support idx=1-10 off / on Define whether sip-stack should support the use of timers. Includes adding headers "Session-Expires" and "Min-SE". Default Value: on user_hold_inactive idx=1-10 off / on Specify if you want to indicate a hold request with sdp parameter send-only or inactive. Some pbx's need the inactive setting for proper music-on-hold operation. Default Value: off keepalive_interval idx=1-10 off / on Specifies whether keepalive message will be sent out to the registrar/proxy port in order to have the port stay open and the phone remain reachable. Default Value: on srv_sip_rtp_base_equal idx=1-10 disabled / enabled Enables/disables RTP from own base station. Default Value: disabled codec_size idx=1-10 20, 30, 40, 60 Specifies the packet size in ms for the respective codec. Default Value: 20 srv_sip_server_alias idx=1-10 Alias for the given SIP server. Default Value: session_timer idx=1-10 e.g. 3600 If timer_support is enabled, this option specifies the SIP session timer in seconds. Default Value: 3600 srv_sip_show_ext_ name_in_hs idx=1-10 off / on Specifies whether the extension is shown on the handset idle screen or not. Default Value: on srv_sip_signal_tcp_port idx=1-10 off / on Specifies whether to signal TCP source port or not. Default Value: on srv_sip_transport idx=1-10 udp / tcp / tls Specifies the transport protocol used for SIP messages. Default Value: udp codec_priority_list idx=1-10 pcmu, pcma, g729, g722, g726 Prioritize which codecs the base should use. Prioritized comma-separated list with max. of 5 entries, most desired codec up front. Default Value: pcmu, pcma, g726 conferencing idx=1-10 e.g. conferencing.snom.com This setting specifies the address or FQDN of a conference server. Default Value: user_host idx=1-10 e.g. server.snom.com Specifies the IP or DNS address of the registrar/ proxy where you want to register this account. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Server Settings Setting Valid Value(s) Description user_outbound idx=1-10 e.g. 10.110.24.111:5060 Specify the outbound proxy in this field (format: addr:port) to ensure all SIP packets are sent via the specified communication point. Default Value: user_expiry idx=1-10 e.g. 3600 Specifies the maximum time between SIP re- registrations in seconds. Default Value: 3600 srv_sip_ua_data_ server_nat_adaption idx=1-10 disabled / enabled Enables/disables NAT adaption. Default Value: enabled. NOTE: srv_sip_use_one_tcp_ conn_per_ext idx=1-10 off / on Specifies whether to use one TCP connection per SIP extension or not. Default Value: off user_full_sdp_answer idx=1-10 off / on When the setting is turned off, the base station returns a list of all available codecs in the SDP in response to INVITE requests. Default Value: off srv_srtp_auth idx=1-10 off / on Determines whether SRTP authentication is used or not. This setting has to be enabled when user_ srtp is set to on. Likewise this has to be turned off when user_srtp is off. Default Value: off user_auth_tag idx=1-10 on = AES-32 off = AES-80 When the setting is set to on, the base station offers an AES-32 auth-tag for SRTP. If turned off, AES-80 is used. Default Value: on srv_use_sip_for_xsi_ login idx=1-10 off: Use the standard method (SIP login or XSI login, if stated) on: Use XSI login with SIP credentials When using SIP credentials as XSI authentication, the base station will make a normal XSI basic authentication using the SIP credentials. This is not a standard, but if the XSI server login credentials match the SIP credentials, this will work. Default Value: off srv_sip_server_alias idx=1-10 e.g. Snom sip server Specifies the name of the sip server. Default Value: Enabled: When the base station receives a SIP response to a REGISTER request with a “Via” header that includes the “received” parameter (e.g.: Via: SIP/2.0/UDP 10.1.1.1:4540;received=68.44.20.1), it will adapt its contact information to the IP address from the "received" parameter. The base station will then send another REGISTER request with the updated contact information. Disabled: The base station will ignore the "received" parameter.

Provisioning Guide M900, M700, M300

Settings and Configuration Extension Settings Extension Settings Setting Valid Value(s) Description subscr_dect_ac_code idx=1-1000 e.g. 1234 subscr_dect_ac_code is a handset-specific setting. If you specify the explicit IPEI for a handset in the config, you can enter a specific access code for that handset. If nothing is used, the default value of ac_code is used when registering handsets. Default Value: subscr_dect_ipui idx=1- 1000 e.g. 018870DF25 Specifies the IPEI number of the handset. Default Value: FFFFFFFFFF subscr_sip_hs_idx idx=1-1000 1, 2, 3, 4, etc. Specifies which handset id is associated to which extension/account, e.g., if set, 1 will use the first configured handset with the first configured account, etc. Default Value: subscr_sip_line_name idx=1-1000 Examples: >8088< (extension number) >Line1< Specifies the line name for the respective extension on this handset. Default Value: subscr_sip_pincode_ dialout idx=1-1000 0-9, *, # Specifies a PIN to be used for outgoing calls. The PIN can be up to 8 digits long Default Value: user_pname idx=1-1000 Specifies the user name that is used for authentication. Default Value: user_pass idx=1-1000 Specifies the password to be used for challenge responses. Default Value: dfks idx=1-1000 off / on Enables/disables device feature key synchronization (DND, FWD, etc.) on the specific identity. Default Value: off user_shared_line idx=1- 1000 0: The extension is not part 1: The extension is part of an SCA Describes whether the extension is part of a BroadWorks shared call appearance (SCA). Default Value: 0 call_waiting idx=1-1000 on / off Enables/disables call waiting indication on the handset. Default Value: on user_active idx=1-1000 off / on The specific account can be disabled by disabling this option. This means that the identity is no longer registered. Default Value: off fwd_busy_enabled idx=1-1000 off / on If turned on and a call is in progress while a second call is incoming, the second caller is diverted to the number specified. Default Value: off You must keep the default if you want to use a repeater.

Provisioning Guide M900, M700, M300

Settings and Configuration Extension Settings Setting Valid Value(s) Description fwd_time_enabled idx=1- 1000 off / on If turned on, any incoming call will be diverted to the specified number after the specified time has elapsed. Default Value: off fwd_all_enabled idx=1- 1000 off / on If turned on, all calls to the associated identity are diverted to the number specified. Default Value: off fwd_busy_target idx=1- 1000 e.g. 123456 Specifies the number to which calls will be diverted when the user is busy. Default Value: fwd_time_target idx=1- 1000 e.g. 123456 Specifies the redirection target when redirection after time is active. Default Value: fwd_all_target idx=1- 1000 e.g. 123456 Specifies the redirection target when redirection is always active. Default Value: fwd_time_secs idx=1- 1000 e.g. 10 Specifies the time in seconds after which the redirection target is redirected when redirection after time is active. Default Value: subscr_sip_ua_data_ server_id idx=1-1000 1 - 10 Specifies the ID of the configured server to be used for that specific handset/account. Example: 2 uses the first configured handset with the second configured server. Default Value: user_name idx=1-1000 Specifies the account with which you register to a SIP registrar/proxy. Default Value: user_mailbox idx=1- 1000 e.g. Snom mailbox Specifies the name for the mailbox that is associated with the particular SIP identity. Default Value: user_mailnumber idx=1- 200 e.g. [email protected] Specifies the number for the mailbox that is associated with the particular SIP identity. Default Value: subscr_sip_ua_pref_ outg_sip_id idx=1-1000 e.g. 1 Specifies which identity is preferred when outgoing calls are made. Default Value: subscr_sip_ua_ subscribed_hs idx=1-20 Values in decimals counted from 1: 1, 2, 4, 8, 16, etc. For your convenience, the complete list of values is provided below. This setting applies only to the M300. The value represents a handset ID for each SIP extension/ account. If set, the corresponding handset subscribes to the given SIP extension/account. Default Value: If you want several handsets to be able to receive calls for the same extension, you have to add up the values of "subscr_sip_ua_subscribed_hs idx" of all handsets. Example: Your primary extension is 100, and, in addition to the handset with "subscr_sip_hs_idx" idx 1, you also want the handsets with "subscr_ sip_hs_idx" idx 2, 3, 4, and 5 to be able to receive calls for this extension. You therefore add up the "subscr_sip_ua_subscribed_hs idx" values of "subscr_sip_hs_idx" idx 1, 2, 3, 4, and 5 and enter the total value of 31 for the subscr_sip_ua_subscribed_hs idx setting of extension 100. Example:

Provisioning Guide M900, M700, M300

Settings and Configuration Extension Settings Setting Valid Value(s) Description 100 ..... 1 31 List of values subscr_sip_hs_idx subscr_sip_ua_subscribed_hs subscr_sip_hs_idx subscr_sip_ua_subscribed_hs idx idx idx idx 1 1 11 1024 2 2 12 2048 3 4 13 4096 4 8 14 8192 5 16 15 16348 6 32 16 32768 7 64 17 65536 8 128 18 131072 9 256 19 262144 10 512 20 524288 subscr_sip_ua_use_ base idx=1-1000 Integers (255, 0, 1, 2 ...) Specifies whether the handset is locked to use a specific base station or not. When locked to a base station, the handset will not be able to make/ receive calls outside the range of this base station. Valid values: 255: Not locked to a specific base station 0: Locked to primary base station 1, 2, 3 etc.: Locked to one of the secondary base stations Default Value: 255 subscr_ua_data_bw_blf_ reslist_uri idx=1-1000 URI for busy lamp field (BLF) resource list on the BroadWorks application server. Only ten characters are allocated for each URI because the server part is provi ded by the server registrar field. Default Value: user_shared_line_ mapping idx=1-1000 e.g., 65535, 65535, 65535, 65535, 65535, 65535, 65535, 65535 This parameter is used for storing the mapping from BroadWorks shared call appearance (SCA) info icons to extension IDs (the extensions should be part of an SCA). Note: Each byte corresponds to one SCA info icon on the handset display. Byte 0 = first icon from the left, byte 1 to the second icon from the left, etc. 0 means that no extension is mapped to the correspond- ing icon. Severyl bytes can have the same value so that corresponding icons monitor call appearances on the same shared line. Default Value: user_realname idx=1-1000 e.g. Max Mustermann Set the name that is associated with each line. This information is also sent out to any party you are calling. Default Value:

Provisioning Guide M900, M700, M300

Settings and Configuration Extension Settings Setting Valid Value(s) Description subscr_ua_data_ emergency_line idx=1-1000 e.g. 1 Specifies which extension is used to perform an emergency call. Default Value: subscr_ua_data_ emergency_number idx=1-1000 e.g. 112 Specifies the emergency number for this handset. Only one number is allowed! Default Value: subscr_ua_data_ emergency_profiles idx=1-1000 e.g., 00000010 Bit map containing the profiles used by the given handset. Default Value: 00000010 xsi_auth_user idx=1- 1000 The BroadWorks XSI user name. Default Value: xsi_auth_pass idx=1-1000 The BroadWorks XSI password. Default Value: keyboard_lock_ emergency idx=1-1000 911 112 110 999 19222 Specifies the emergency numbers that can be dialed when the handset is locked. Separate the individual emergency numbers by one space. Default Value: Emergency numbers are hardcoded in accordance with the country code and cannot be changed.

Provisioning Guide M900, M700, M300

Settings and Configuration Repeater Settings Note: You cannot add a repeater/repeaters if you have defined a specific access code (AC) in the extension settings (subscr_dect_ac_code). All handsets must have the default value . Repeater Settings Setting Valid Value(s) Description repeater_auto_config_ mode idx=1-100 0 = Manual 1 = Local Automatical 2 = Chaining If set to 0 (= manual), specify repeater_rpn and repeater_sync_src_rpn. If set to 1 (= local), the repeater will automatically search for available base stations and locate the base with the best signal. If that base station is turned off, the repeater will move to the next best base station. If set to 2 (= chaining), all base stations and all repeaters will send RSSI reports to the primary base station. These reports are used by the primary base station to create a DECT synchronization tree with all base stations and all repeaters that have this setting configured. Default Value: 0 repeater_data_ configured idx=1-100 off / on When this setting is set to on, the specific repeater is actively configured; when set to off, this account is disabled. Default Value: 0 repeater_dect_ipui idx=1-100 Repeater International Portable User Identity. This is normally not configured via provisioning. Default Value: repeater_name idx=1-100 Specifies the name of the Repeater. Default Value: repeater_rpn idx=1-100 1, 2, 3 The setting is used when repeater_auto_config_ mode is set to manual. Together with the setting repeater_sync_src_rpn, this allows to specify a unique RPN value per repeater. Default Value: 0

Provisioning Guide M900, M700, M300

Settings and Configuration Repeater Settings Setting Valid Value(s) Description repeater_sync_src_rpn idx=1-100 0, 1, 2, 3, 4, 5, etc. The setting is used when repeater_auto_config_ mode is set to manual. Together with the setting repeater_rpn it is possible to specify a unique RPN value for every repeater. The maximum chain length is three repeaters in a chain after the base station. All repeaters using manual mode must be configured to use a unique RPN. By default, this setting uses the base station at index 0 in network_sync _mac_chain as the DECT synchronization source. Value 1 uses the repeater with RPN 1 which is connected to the base station in network_sync_mac_ chain index 0 as the DECT sync source. Value 2 uses the repeater with RPN 2 which is connected to the base station in network_sync_mac_ chain index 0 as the DECT sync source. Value 3 uses the repeater with RPN 3 which is connected to the Base station in network_sync_mac_ chain index 0 as DECT sync source. Value 4 uses the base station at index 1 in network_ sync_mac_chain as the DECT sync source. Value 5 uses the Repeater with RPN 1 which is connected to the base station in network_sync_mac_ chain index 1 as the DECT sync source. Default Value: 0

Provisioning Guide M900, M700, M300

Settings and Configuration Multicell Settings Multicell Settings Setting Valid Value(s) Description network_allow_multi_ primary off / on This setting specifies whether the configuration of multiple primaries in a network is allowed or not. Default Value: off network_auto_multi_ primary off (1) / on (2) This setting specifies whether auto configuration is enabled/disabled for multiple primaries in a chain.(1,2) Default Value: off (1) When set to off, one primary base station and one or more secondary base stations are allowed per multicell system on a network (LAN). When the primary base station is down or removed from the system, the system will define a backup primary base station. Any of the secondaries can be used. (2) When set to on, there are two options. Please see M700 Multicell Deployment Guide for more information. • A multicell system with 2 or more separate cell systems with the same system chain ID in one network (LAN), each cell system with its own primary base station. • A multicell system with one primary base station and 2 separate cell systems with the same system chain ID in one network (LAN), The primary is located between the two cell systems, its DECT range overlapping with each of them. network_dect_auto_ sync_tree_config off / on Specifies whether the DECT sync tree is automatically configured or not. Default Value: on network_roaming_ deregister off / on This setting specifies how SIP registrations are handled when a handset roams from one base station to another. Roaming is defined as the procedure when the handset moves its SIP and DECT registration from one base station to another. Some PBXs are capable of handling multiple SIP bindings per SIP user and, consequently, when a new SIP registration is made from a different base, the old SIP registration will still be valid. As a consequence, this registration has to be deactivated. Other PBXs always use the latest SIP registration and therefore no deregister is needed. "Off" means that no sip deregister takes place when a handset roams from one base to another, while "on" means that the old SIP registration is deleted when a handset roams from one base to another. Default Value: off network_sync_chain_id Valid: Up to 5 digits Specifies the identity of a given multicell chain. This is used to identify different chains in the same location. Default Value: 512 network_sync_data_ transport multicast / peer-to-peer Specifies the data transport method for multicell setups. Default Value: network_sync_debug_ enable off / on Specifies whether the network sync debug is enabled or not. Default Value: off network_sync_enable off / on Specifies whether multicell mode is enabled or not. Default Value: off

Provisioning Guide M900, M700, M300

Settings and Configuration Multicell Settings Setting Valid Value(s) Description network_sync_max_sip_ reg_per_base Valid: 8, 9 ... 30 This setting specifies the maximum number of SIP registrations per base station. When a base station in a multicell system has registered its maximum, it will attempt to distribute any additional SIP registration to other base stations in the chain that are detectable by the handset with the SIP registration. If this is not possible, the base station will reject registrations exceeding its maximum. Default Value: 8 network_sync_primary_ static_ip Specifies a static IP to be used as primary data sync address when communicating via peer-to-peer. Default Value: 0.0.0.0 network_sync_time e.g. 60 This is the time in seconds for keep-alive packets to be sent between members of the chain. If no keepalive packets are received within double the value of the time, the base will be treated as unreachable in the multicell setup. Minimum recommended value is 30. Default Value: 60 network_dect_sync_tree idx=1-50 Specifies the DECT sync ID tree that the base stations are using as their DECT sync source. It will be overruled by the setting network_dect_auto_sync_ tree_config, if that setting is enabled. If a base's ID for its own index is equal to its own ID, then this base is the primary DECT sync source. A secondary base which cannot find its sync source or has been turned off will get a value of 240 which will start it looking for any base station and sync source. This will then enable the system to reconfigure itself. Default Value:0 network_sync_mac_ chain idx=1-50 This setting is not supposed to be used in provisioning since it can be critical if the order of the base stations is changed. The list contains the chain of Ethernet MAC addresses that are connected in the specified network. The chain will be created automatically by the multicell system, but can also be created by provisioning. network_sync_static_ip_ chain idx=1-50 Do not use this setting in provisioning. It is a list that is only used when multicell and peer-to-peer synchronization are enabled, and it is automatically updated by the primary base station when a secondary base station boots. The list contains the static IP addresses of all base stations in a peer-to- peer multicell system and is used to communicate with the other base stations.

Provisioning Guide M900, M700, M300

Settings and Configuration Emergency Settings Emergency Settings Setting Valid Value(s) Description alarm_howling idx=1-100 off / on Defines whether howling in the handset is enabled when the handset is calling the alarm number. Default Value: off alarm_signal idx=1-100 off / call Defines the way an alarm is signaled. Currently only the phone call is active. Default Value: off alarm_stop_allowed idx=1-100 on / off Defines whether it is possible to stop the alarm from the handset. Default Value: on pre-alarm_delay idx=1-100 Integers, e.g., 0, 1, 2 ... Defines the delay in seconds from the moment the alarm is triggered until it fires. Default Value: pre_alarm_stop_allowed idx=1-100 on / off Defines whether it is possible to stop the alarm from the handset. Default Value: on profile alias idx=1-100 alphanumerical characters, max. 19 characters Alias for the given emergency alarm profile. Default Value: trigger_delay idx=1-100 Integers, e.g., 0, 1, 2 ... Defines the number of seconds from the moment the handset's alarm button is pressed until the handset calls the alarm number or, if a pre-alarm_delay has also been configured, until the pre-alarm_delay is triggered. Default Value: 0

Provisioning Guide M900, M700, M300

Settings and Configuration Device Type Settings These settings hide the respective menu items so that handset users won't be able to active the specific functions. Device Type Settings Setting Valid Value(s) Description pp_menu_hide_cfb type=M70 off / on Hides call forwarding when busy in the menu of registered M70 handsets. Default Value: off pp_menu_hide_cfna type=M70 off / on Hides call forwarding no answer, i.e., call forwarding after timeout, in the menu of registered M70 handsets. Default Value: off pp_menu_hide_cfu type=M70 off / on Hides call forwarding unconditional, i.e., forwarding of all calls, in the menu of registered M70 handsets. Default Value: off pp_menu_hide_dnd type=M70 off / on Hides "do not disturb" setting in the menu of registered M70 handsets. Default Value: off pp_menu_hide_hide_number type=M70 off / on Hides the setting "hide number" (CLIR) in the menu of registered M70 handsets. Default Value: off pp_menu_hide_silent type=M80 off / on Hides silent mode in the menu of registered M80 handsets. Default Value: off pp_menu_hide_cfb type=M80 off / on Hides call forwarding when busy in the menu of registered M80 handsets. Default Value: off pp_menu_hide_cfna type=M80 off / on Hides call forwarding no answer, i.e., call forwarding after timeout, in the menu of registered M80 handsets. Default Value: off pp_menu_hide_cfu type=M80 off / on Hides call forwarding unconditional, i.e., forwarding of all calls, in the menu of registered M80 handsets. Default Value: off pp_menu_hide_dnd type=M80 off / on Hides "do not disturb" setting in the menu of registered M80 handsets. Default Value: off pp_menu_hide_hide_number type=M80 off / on Hides the setting "hide number" (CLIR) in the menu of registered M80 handsets. Default Value: off pp_menu_hide_silent type=M80 off / on Hides silent mode in the menu of registered M80 handsets. Default Value: off pp_menu_hide_cfb type=M90 off / on Hides call forwarding when busy in the menu of registered M90 handsets. Default Value: off pp_menu_hide_cfna type=M90 off / on Hides call forwarding no answer, i.e., call forwarding after timeout, in the menu of registered M90 handsets. Default Value: off

Provisioning Guide M900, M700, M300

Settings and Configuration Device Type Settings Setting Valid Value(s) Description pp_menu_hide_cfu type=M90 off / on Hides call forwarding unconditional, i.e., forwarding of all calls, in the menu of registered M90 handsets. Default Value: off pp_menu_hide_dnd type=M90 off / on Hides "do not disturb" setting in the menu of registered M90 handsets. Default Value: off pp_menu_hide_hide_number type=M90 off / on Hides the setting "hide number" (CLIR) in the menu of registered M90 handsets. Default Value: off pp_menu_hide_silent type=M90 off / on Hides silent mode in the menu of registered M90 handsets. Default Value: off

Provisioning Guide M900, M700, M300

Settings and Configuration Firmware Settings Firmware Settings Setting Valid Value(s) Description firmware-settings Container for all firmware-related tags which must be the root node in the settings file. All firmware- related settings must be inside this tag, i.e., firmware-status e.g. http://www.company. com/settings/snom XXX- firmware.htm Defines the URL of the firmware configuration file where all firmware related settings are stored. Default Value: firmware e.g. http://server/directory/ This setting defines a specific path where the firmware can be found. Only the first part of the URL can be defined, i.e. http://server/directory/. The base will then always try to automatically find the respective sub-directory for the model that is used, e.g. /directory/M700 or /directory/M65. Default Value: fp_fwu_sw_version e.g. 323 Defines the base station firmware version. Default Value: pp_fwu_sw_version type=M65 pp_fwu_sw_version type=M25 pp_fwu_sw_version type=M5 e.g. 323 Defines the firmware version for the attached devices (handsets and repeaters). The "type" parameter defines which type of device is used, i.e., M65, M25, M5, etc. Default Value: 0

Provisioning Guide M900, M700, M300

Settings and Configuration Phonebook Settings Phonebook Settings Setting Valid Value(s) Description phone-book (or tbook) Snom phonebook tag. This has to be the root node if used within the main configuration file. item The item tag defines one directory contact entry. For an entry to become valid, at least one name and one number must exist. first_name (or name) e.g. Thomas Defines a contact's first name. Default Value: last_name e.g. Miller Defines a contact's last name. Default Value: number idx=1-3 e.g. 1234567 Defines a contact's number. A phonebook item can have from 1 to 3 numbers attached. If idx is not provided, it defaults to 1. Default Value: 1 number_type idx=1-3 home, mobile, work, other Defines the type of telephone number. The number_ type for a given idx defines the icon to display next to the number having the same idx. If idx is not provided, it defaults to 1. Default Value: 1 File Settings File Settings Setting Valid Value(s) Description file e.g. Command tag causing the specified URL to be loaded and handled as any other setting file. Format: The file being pointed to has to be a fully qualified xml file. The following macros are supported in the url: {prov_host} {phone_ip}

Provisioning Guide M900, M700, M300

Settings and Configuration Examples for Configuration Files The following six examples of configuration files show how setting files are configured. Please remember that these setting files are only meant to be guidelines; every value within each tag has to be changed, if needed. All configuration files must be saved in ANSI format to avoid any problems with the encoding of certain characters. Basic Configuration 1: 1 handset, 1 base station Basic Configuration 2: 3 handsets, 1 base station, SRTP & TLS on, German language used on all devices Basic Configuration 3: 1 handset, 1 base station, two different lines and a different access code Basic Configuration 4: 1 handset, 1 base station, phonebook included in settings file Basic Configuration 5: Allows the inclusion of both firmware and phonebook-related settings in the provisioning process. Each file contains specific settings and is loaded separately, avoiding any root tag conflicts. The file will automatically check for and fetch the latest build of any given firmware release whenever the base is provisioned. Multicell Configuration (M900/M700 only): Example for multicell provisioning, two (2) base stations Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values.

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 1 - 1 base station, 1 handset This configuration creates a setup where the specified handset under subscr_dect_ipui has exactly one line and a mailbox number configured. 10.110.21.254 Server 123 10.110.22.37 off off FFFFFFFFFF 1 1 1 Line1 on 502123 Max 123 snom voicemail *97 911 112 110 999 19222 Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values. Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values.

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 2 - 1 base station, 3 handsets This configuration uses SRTP & TLS and German language on all devices: GER GER+1 Deutsch Deutsch 10.110.21.254 Server 123 10.110.22.37 on on tls FFFFFFFFFF 1 1 1 Line1 FFFFFFFFFF 2 1 1 Line1 FFFFFFFFFF 3 1 1 Line1 on 502111 Max 111 on 502222 Max 222 on 502333 Max 333

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 3 - 1 base station, 1 handset, 2 lines with different access codes This configuration creates a setup where a handset has two different lines under which it can be reached. 10.110.21.254 1111 Server 123 10.110.22.37 off off Server 456 10.110.22.223 off off FFFFFFFFFF 1 1 1 Line1 1 2 1 Line2 on 502111 Max 111 on 5007 Max 222 Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values. Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values.

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 4 - 1 base station, 1 handset, phonebook in settings file This configuration includes a phonebook that is loaded and updated each time the base is provisioned. Max Mustermann 9000 work 1122334455 mobile 6789546 home Peter Jansen 9001 mobile 10.110.21.254 Server 123 10.110.22.37 off off FFFFFFFFFF 1 1 1 Line1 on 502123 Max 123 snom voicemail *97 911 112 110 999 19222

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 5 - Provisioning Firmware and Phonebook Settings This method allows the inclusion of both firmware and phonebook-related settings in the provisioning process. Each file contains specific settings and is loaded separately, avoiding any root tag conflicts. The file will automatically check for and fetch the latest build of any given firmware release whenever the base is provisioned. Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values. Main Provisioning Configuration file firmware.xml http://10.110.22.8/firmware/snom 323 323 Snom_phonebook.xml Max Mustermann 9000 work 1122334455 mobile 6789546 home Peter Jansen 9001 mobile

Provisioning Guide M900, M700, M300

Settings and Configuration Snom_settings.xml 10.110.21.254 Server 123 10.110.22.37 off off FFFFFFFFFF 1 1 1 Line1 on 502123 Max 123 Snomvoicemail *97 911 112 110 999 19222

Provisioning Guide M900, M700, M300

Settings and Configuration Basic Configuration 6 - Multicell Two config files are necessary to set up a multicell installation: Multicell settings and primary base station settings. The multicell settings must be downloaded to all base stations in the multicell installation; the primary base station settings are downloaded to the primary base station only. Make sure that you replace the sample values like IP and MAC addresses, rtp ports, etc., with your actual values. See the settings tables for valid and default values and explanations. Multicell Settings for Primary Base Station and Secondary Base Stations off off 1 on on peer-to-peer off 60 8 192.168.11.232 off 1 Primary Base Station Settings This is an example with EU daylight saving time, German time zone, German language, etc. Replace sample values with your system and localization settings. Please see settings tables for explanations and valid values. on on on on 0 Master 2 7 50004 50043 GER on on auto on 3 0

Provisioning Guide M900, M700, M300

Settings and Configuration 2 1 5 10 0 2 1 5 GER+1 Deutsch Deutsch cn telephoneNumber mobile homePhone phonebook.php http://192.168.1.10/ucware/prov/snom-dect/ 3600 0 90 on 80 off off 0 184 160 off off 0 " off off on off 7 0 off 192.168.1.10 on on on on 140 on off

Provisioning Guide M900, M700, M300

Settings and Configuration off off disabled disabled 101 off udp off 20 pcma, g722, pcmu on 60 on 666 Siegfried Atan 666 on off off off 20 1 666 1 80 025482b179 0112 1 255 1 off on 80 555 Nadja Appel 555 on off off off 20 2 555 1 80

Provisioning Guide M900, M700, M300

Settings and Configuration 025482b16c 0112 2 255 1 off on 80 1 0 016e81b0d0 Hallway_01 on 1 on 2 1 016e87bda0 M5-02 on 0 !no_value! (2)