SmartLock VISION Technical Manual
Text of the manual
VISION TECHNICAL MANUAL
Default codes (change default codes)
Setup (Master)
5-0-5-0-5-0-5-0
Service
not installed
Manager
1-2-3-4-5-6
Users (1-9)
not installed
Open the lock
• Enter the code and open within 4 seconds.
• If time delay is set wait for counting: an acoustic signal indicates open window.
• Enter the code and open within 4 seconds.
Open the lock with time delay override
• Enter override user (9) code.
• Enter second code and open within 4 seconds.
If lock is already counting time delay enter override user (9) code to immediately open.
Change code (door open)
• Press and hold 0 until double beep: enter old code.
• Enter and confirm new code.
Install a user
• Press and hold 1 until double beep: enter Manager code.
• Enter user ID (1-9).
• Enter and confirm new user code.
To install Manager enter the function with Service code.
Users management
• Press and hold 2 until double beep: enter Manager code.
• Press P to scroll users list and check their status.
• Press 1 to install a user: enter and confirm user code.
• Press 2 to disable/enable a user.
• Press 3 to delete a user.
• Press OK to confirm and exit.
Delete a user
• Press and hold 3 until double beep: enter Manager code.
• Enter user ID (1-9).
To delete Manager enter the function with Service code.
Test function
• Press and hold 5 until double beep.
• Enter the sequence: 1-2-3-4-5-6-7-8-9-0.
• Double beep: key properly working. Long beep: key malfunction.
If lock and keypad don’t communicate display shows the message: NO ANSWER.
1 of
2
OPEN
LOCK
CODE
o o o o o o
INSTALL
o o o o o o
CHANGE
o o o o o o
ID= 1
ID= 2
ID = 3
DELETE
o o o o o o
TEST
Change Setup code (Master)
• Press and hold 8 until double beep, enter Setup code and select function 0.
• Enter and confirm new Setup code.
Install Service
• Press and hold 8 until double beep, enter Setup code and select function 1.
• Press OK to confirm the operation.
• Enter and confirm new Service code.
Delete Service
• Press and hold 8 until double beep, enter Setup code and select function 3.
• Press OK to confirm the operation.
Reset lock
• Press and hold 8 until double beep, enter Setup code and select function 5.
• Display shows the message RESET.
• Press OK to confirm the operation.
• Enter a valid code.
• Lock is in pre-setup mode.
Pre-setup mode
• To open press 1.
• Setup code (Master) 5-5-5-5-5-5-5-5.
Lock setup
• Press and hold 8 until double beep. Enter the Setup code 5-5-5-5-5-5-5-5.
• Display shows the following options (press P to scroll):
• CHANGE: change Setup code to exit pre-setup mode.
• SETUP: check (OK) or change (P) lock configuration (bold = default settings)
• DELAY DOWN - DELAY UP: time delay counting up or down.
• DUAL NO - DUAL YES: dual mode active - dual mode not active.
• DIGITS 6 - DIGITS 7 - DIGITS 8: opening codes length.
Time delay
• Press and hold 9 until double beep and enter Manager code (or Service code) or
access Setup menu and press 9.
• Display shows current time delay values: press OK to confirm or enter new values
(00-99min) and press OK.
• Display shows current open window values: press OK to confirm or enter new values
(01-19min) and press OK.
Time delay can be increased at any moment, decreased only during open window.
Change language and check firmware version
• Press and hold OK until double beep: display shows serial number and firmware
version: press P.
• Display shows current language: press OK until the desired language will be selected.
2 of
2
ENGLISH
ITALIAN?
42C1AH90
VER. 01.01
DELAY
o o o o o o
FUNCTION
0 1 3 5 6 7 9
FUNCTION
0 1 3 5 6 7 9
FUNCTION
0 1 3 5 6 7 9
FUNCTION
0 1 3 5 6 7 9
RESET
WINDOW
02min?
DELAY
05min?